HomeWorks QS Processor



Similar documents
QSE-CI-NWK-E Control Interface

QSE-CI-DMX Control Interface

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

Application Note #537 Revision D August 2015 Solutions for Upgrading from HomeWorks Illumination to HomeWorks QS

HomeWorks QS Wired Signature SeriesTM Keypads

HomeWorks QS Wired seetouch Designer Keypads

Control Interfaces. GRAFIKR Systems a LUT-DMX

Remote Power Panels with Breakers

IP Link Device Interface Ethernet Communication Sheet

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

OMX-RS232 Control Interface

RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! RadioRA2 Inclusive Software v5.0.8 or newer

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

HomeWorks QS Wired seetouch Architectural Keypads

Phase-Adaptive Power Module

Switching Power Module

Lutron. integration protocol

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

MechoNet TM Network Interface (MNI) Specification Submittal

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

RF Maestro Local Controls

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Temperature Control from Lutron

GRX-PWM Pulse Width Modulation Interface

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

How To Use A Lutron Power Supply

Long Range Ethernet Extender

Total installed cost comparison study of motorized shading systems. line voltage AC system vs. low voltage Sivoia QS system

Dual Technology Ceiling Mount Sensor

IntesisBox Modbus Server SAMSUNG Air Conditioners

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

IntesisBox Modbus Server Fidelio IP

Waveguide Access Point WGA631. Product Guide

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System

HomeWorks QS. Save energy with unparalleled total home control

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Design guide EcoSystem

How To Use A Ds340 (Dsp)

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

KNX Panasonic Air Conditioners

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

CompactRIO crio-9052

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

IntesisBox KNX - LON

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Telephone- and leased line modem for industrial applications TD-36

T7079A,B Solid State Remote Temperature Controllers

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Zero-Variable Outdoor Wireless Radio. Datasheet. Models: BM2-Ti, BM5-Ti. Fully Integrated Radio. Weatherproof Aluminum Casing

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Lighting Control Systems

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Rack mounted telephone- and leased line modem for industrial applications

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Moxa EtherDevice Switch

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Megapixall Security Tools & Accessories

Electronic Control Devices The European Product Catalogue 2007

LIEBERT VNSA Installation Sheet

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Reference Design. conference rooms

PCS0100en Persy Control Services B.V. Netherlands

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Provides one channel for Ethernet over existing

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

IntesisBox KNX Modbus TCP master

Long Reach PoE over Coaxial Extender Kit

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

TAC Xenta. TAC Xenta 511 and 911 Handbook

SMART Board interactive flat panel with appliance Model 8055ie-SMP

Temperature & Humidity SMS Alert Controller

Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Provides one channel for Ethernet over existing

Energy Communication Unit (ECU)

CAEN Automation Enclosures

Foxboro Evo Process Automation System


TrueAlarm Fire Alarm Systems

Security & Control Cables

Transcription:

product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication between multiple processors. processors may be connected using either standard networking or using ad-hoc networking. All processors on a project must be connected to a single network. The software and all integration equipment must be connected to the same network as the processors. The processor is powered from the power supply. Refer to the software to determine link power requirements. The processor can be installed in an HQ-LV21 enclosure. Processor Capabilities Each processor has 2 links that can be individually configured as one of three types: HomeWorks / Power Panels 16 addresses / 256 zones Wired Device Link 100 devices / 500 zones Control Interfaces Dynamic Keypad seetouch Keypad GRAFIK Eye QS Control Unit Sivoia QS shades RF Link 100 devices / 100 zones Dynamic Keypad Maestro Dimmers/Switches Lamp Dimmers RF seetouch Keypad Sensors, Occupancy/Vacancy Sivoia QS Wireless Shades Tabletop Keypad GRAFIK Eye QS Control Units Model Number HQP6-2-120 Lutron 1

product specifications 369-376a Specifications Model Numbers Power Typical Power Consumption Regulatory Approvals Environment Heat Generated Cooling Method Power Failure Memory Internal Timeclock Miswire Protection Low-Voltage Link Wire Type Low-Voltage Power Wire Type Communications Link Capacities ESD Protection Surge Protection Mounting Dimensions HQP6-2-120 Processor (P): - 250 ma Links (L1 / L2): - 2 A per link 5 W; 8 Power Draw Units (PDUs) conditions: Two Ethernet links connected, both device links in use UL, cul Indoor use only. 32 F and 104 F (0 C and 40 C), 0% to 90% humidity, non-condensing 17 BTU/hr typical (24 BTU/hr with 2 links at 2 A each output) Passive Cooling System data stored in non-volatile memory. Timeclock retention for 10 years ±1 minute per year All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts. Two pair one pair 18 AWG (0.75 mm 2 ), one pair 18 to 22 AWG (0.34 to 0.75 mm 2 ) twisted shielded IEC PELV / NEC Class 2 cable 18 AWG (0.75 mm 2 ) Ethernet, RS485 (QS, RF, Power Panel) HomeWorks / Power Panels 16 addresses / 256 zones Wired Device Link 100 devices / 500 zones RF Link 100 devices / 100 zones Meets or exceeds the IEC 61000-4-2 standard Meets or exceeds ANSI/IEEE C62.41 standard Mounts in HQ-LV21 enclosure With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm) Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm) Connections Two 5-pin removable terminal blocks* for Links 1 and 2. One 5-pin removable terminal block* for Power Input. Two RJ-45 standard Ethernet connections. *Each terminal will accept up to two 18 AWG (0.75 mm 2 ) wires. Warranty 8 Year Limited Warranty. http:///resiinfo NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. 2 Lutron 24/7 Technical Support 800.523.9466

product specifications 369-376 Dimensions Dimensions shown as: in (mm) Front View 4.27 (108) Side View 5.26 (134) 6.0 (152) 1.06 (26.9) Lutron 3

PWR ERR P P L1 L1 TX/RX L2 L2 TX/RX L(+) N(-) PWR ERR P P L1 L1 TX/RX L2 L2 TX/RX product specifications 369-376a Mounting DIN Rail Power Supply () (5) Ground (4) Red L2 (Link 2) Power (3) Red L1 (Link 1) Power (2) Red P (Processor) Power (1) Black COM (Common) Wire Landing Boards (QS-WLB) 4 Lutron 24/7 Technical Support 800.523.9466

L(+) N(-) product specifications 369-376 Wiring Diagrams Networking Standard Networking: Connection using an Ethernet hub/switch/router HQ-LV21 Panel with 2 processors Ethernet cable: Cat5/Cat5e 328 ft (100 m) maximum per home run processors Ethernet Router WAN LAN Laptop PC Ethernet cable: Cat5/Cat5e 328 ft (100 m) maximum per home run processor Ad-hoc Networking: Direct Ethernet connection from PC to processors Ethernet cable: Cat5/Cat5e 328 ft (100 m) maximum each run 328 ft (100 m) max 328 ft (100 m) max 328 ft (100 m) max Laptop PC processor processor processor Up to 5 processors can be daisy-chained Lutron 5

product specifications 369-376a Wiring Diagrams Power Panel Link Power Panel Link* Up to 16 addresses total * Pin 2 does not get connected when using a power panel link. 6 Lutron 24/7 Technical Support 800.523.9466

Power 9 V Hybrid Repeater Repeater Status P 1 2 3 4 Communication Setup Repeater Link RF COM 1 2 3 4 Add Wired Activate Power 9 V Hybrid Repeater Repeater Status P 1 2 3 4 Communication Setup Repeater Link RF COM 1 2 3 4 Add Wired Activate Power 9 V Hybrid Repeater Repeater Status P 1 2 3 4 Communication Setup Repeater Link RF COM 1 2 3 4 Add Wired Activate product specifications 369-376 Wiring Diagrams RF Link HQP6-2-120 30 ft (9m) maximum RF Device Hybrid Repeater RF Device RF Device RF Link* 1000 ft (305 m) maximum wire length per run 30 ft (9m) maximum 60 ft (18 m) maximum RF Link* 1000 ft (305 m) maximum wire length per run 30 ft (9m) maximum * Hybrid Repeaters can be powered from the Processor link or a wall-mount transformer. If powering from a wall-mount transformer, Pin 2 does not get connected. Lutron 7

L(+) N(-) L(+) N(-) product specifications 369-376a Wiring Diagrams QS Link QS Link QS Link Max 2A combined Draw from processor when powering both links from the same power supply up to 99 device addresses up to 99 device addresses Wiring Diagrams Link Power More current can be supplied by an additional power supply (1) Black COM (Common) (4) Red L2 (Link 2) Power (5) Ground (3) Red L1 (Link 1) Power (2) Red P (Processor) Power (1) Black COM (Common) 2 A 2 A Max 2 A per link when using a separate power supply for each link 8 Lutron 24/7 Technical Support 800.523.9466

product specifications 369-376 Wiring Diagrams QS Wired Device Link with Shades (Controllable Window Solutions) 120 V~ 60 Hz QS Link wired devices QSPS-P1-10-60 QS Smart Power Panel wired devices Lutron 9