PMC Solid State Memory Card Product Manual V1.0 2010-03-01



Similar documents
RAID Option Installation

Serial ATA RAID PCI. User's Manual

SATA II 4 Port PCI RAID Card RC217 User Manual

760 Veterans Circle, Warminster, PA Technical Proposal. Submitted by: ACT/Technico 760 Veterans Circle Warminster, PA


High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

Serial ATA 4-Channel RAID Quick Installation Guide

Serial ATA RAID PCI Card

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

Low Profile Ultra ATA-133 RAID PCI Host

RAID installation guide for ITE8212F

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

PCI SATA Controller Card Model: SY-PCI40010

6-Port SATA II 150 PCI Host Card w/raid

Encore SATA2 RAID PCIe Card

AMD RAID Installation Guide

PCI SATA RAID Card User Manual

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Ultra ATA 133 RAID PCI Pro

Guide to SATA Hard Disks Installation and RAID Configuration

VIA / JMicron RAID Installation Guide

SATA 150 RAID. user. Model MAN UM

SSDNow For Desktops. Installation Guide

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

README.TXT

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4

Rugged & Reliable Data Storage Solid-State State Flash Disk overview

NVIDIA RAID Installation Guide

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

AMD RAID Installation Guide

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Beckhoff onboard SATA-RAID

SATARAID5 Serial ATA RAID5 Management Software

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

VIA RAID Installation Guide

Intel Matrix Storage Manager 8.x

SATA II 3Gb/s SSD. SSD630 Benefits. Enhanced Performance. Applications

Intel Rapid Storage Technology

Embedded Operating Systems in a Point of Sale Environment. White Paper

Manual IB-3620 Series

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

PCI SATA + PATA Raid Card

FUSION R400 RAID USB 3.0

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

English. Configuring SATA Hard Drive(s)

SiI3132 SATARAID5 Storage Management Software User Manual

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE

This chapter explains how to update device drivers and apply hotfix.

RAID OPTION ROM USER MANUAL. Version 1.6

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

Installing and Configuring SAS Hardware RAID on HP Workstations

VIA RAID configurations

Product Information. DE2-TIGER PMC Module Quad Serial ATA Controller & 1.8-Inch Hard Disk Drive

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

FASTTRAK USER MANUAL TX2200, TX2300. Version 3.2

PCI ATA 133 RAID Controller Card. User Manual

RAID installation guide for Silicon Image SiI3114

This user guide describes features that are common to most models. Some features may not be available on your computer.

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

Dynamode External USB3.0 Dual RAID Encloure. User Manual.

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

ESATA PCI CARD. User s Manual

RocketRAID User, s Manual. Revision: 1.0 Date: Sept HighPoint Technologies, Inc.

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

Guide to SATA Hard Disks Installation and RAID Configuration

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

SATA II-150 PCI RAID

VT8237 SATA RAID User Manual

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

ITE RAID Controller USER MANUAL

Guide to SATA Hard Disks Installation and RAID Configuration

SATA II PCIe RAID Quick Installation Guide

RAIDXPERT USER MANUAL. Version 2.1

SATA RAID Function. (Only For Chipset Sil 3112 /Sil 3512 Used) USER S MANUAL 12M E-SI

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

PCI Express SATA / esata 6Gb/s RAID Card User Manual

SATA II PCIe RAID Quick Installation Guide

Configuring a SSD RAID-0 Array on an AMD System

Architecting High-Speed Data Streaming Systems. Sujit Basu

PCIe SATA 6G Raid Card

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER

Intel RAID SSD Cache Controller RCS25ZB040

Serial ATA ( ULi M1573)... 2

LSI Software RAID Configuration Utility

2-Serial/1-Parallel Port PCI Adapter RC303 User Manual

Transcription:

PMC Solid State Memory Card Product Manual V1.0 2010-03-01

Revision History Release Version Date Description Beta1 2010-3-1 First Edition Copyright

Reference ANSI/VITA 47-2005, Environments, Design and Construction, Safety, and Quality for Plug-In Units VITA 48.0 (Draft) Mechanical Specifications for Microcomputers Using Enhanced Ruggedized Design Implementation (ERDI) IEEE STD 1386-2001, IEEE Standard for a Common Mezzanine Card Family: CMC

Table of Contents Content... Error! Bookmark not defined. 1. Overview... 5 2. Details... 7 2.1 Parameters... 7 2.2Functional Diagram... 9 2.3 Functional Instructions... 10 2.4 Destruction Function... Error! Bookmark not defined. 2.4 Performance Table... 12 3. Installation Instruction... 13 3.1 Hardware Installation... 13 3.2 X86 Platform BIOS RAID Configuration... 14 3.3 Driver Installation... Error! Bookmark not defined. 3.4Partition Configuration... 16 3.5 Boot-up Configuration... 17 4. Selection Guide... 18 4.1 Selection Table... 18 4.2 Optional Accessories... 18 5. Caution... 19

1. Overview RunCore Hurricane Series, the first generation of PMC solid-state memory card (RCH-I-PU3 series Solid State Storage Card), in compliance with standard design IEEE1386.1,Air-cooling standard design,support two types of flash storage media SLC and MLC, capacity range - 32GB~128GB(SLC)and 32GB~512GB(MLC)respectively. RCH-I-PU3 Series PMC solid-state memory card support software RAID feature PCI-SATA bridge chip, and two SATA solid-state memory cell constituted is compatible with 32bit 33/66MHz PCI Transfer Protocol. It provides two equal sets of SATA SSD storage spaces, each set of space s write and read speed is up to 70MB/S. Using different operating system like Window, Linux and Vxworks, it then enable to do RAID0 (Stripe) and RAID1 (Mirror) mode of data transmission, which also provides the features such as superior performance and data security. Under the RAID0 (stripe) mode of data transition, its speed is up to 120MB/S. The storage card is using the industrial level of SATA SSD controller, which provides a reliable ECC standard. Using flash as the storage medium, it has a quite working performance. The storage is using a Loss balance algorithm and bad block management techniques to ensure that the users can access accurately and consistently. Flash s life is generally restricted by the number of times of accessing. In order to extend the life of the hard disk, one key self-destruction has integrated the benefits of balance of loss of special algorithm and bad block management algorithm, which ensure that the hard disk read and write cycles will cover all of the flash memory area. This algorithm can eliminate the repeated operation in one single memory area, which prevents the flash memory blocks in advance by wear and tear. Without power supplied, data in Runcore s solid state disk storage can still maintain up to 10 years validity. Under any certain circumstances, stored data can extend the retention period and there would not be any sudden loss. Compared with the mechanical hard drive, RCH-I-PU3 Series PMC solid-state memory card does not use any mechanical moving parts. With superior performance, high reliability and low power consumption, these advantages able to adapt wide flexibility application in

different kinds of environment, which also has a broad application prospects in military aerospace defense. Features: All solid states are high-speed; large capacity; reliable; security; shock-proof; wide temperature range

2. Details 2.1 Parameters Item Parameters Physical Specifications Interface Dimension (WxL) Stacking Height PMC Pn1&Pn2 74mmx149mm 10mm Weight <100g Identifiable SSD 2*SATA Voltage 3.3V Operating Power Static Power <5.5W <1.2W Capacity SSD Capacity SLC: 16GB~64GB 1 MLC: 16GB~256GB Total Capacity SLC: 32GB~128GB 2 MLC: 32GB~512GB Performance Single Disk Sustained SLC 70MB/s 3 MLC 70MB/s 3 Write Speed Single Disk Sustained SLC 90MB/s 3 MLC 90MB/s 3 Read Speed RAID0 Sustained SLC 120MB/s 3 MLC 120MB/s 3 Write Speed

RAID0 Sustained SLC 120MB/s 3 MLC 120MB/s 3 Read Speed Compatibility Transfer Protocol Compliant with PCI Specification, revision 2.3 PCI 32bit 33\66MHz 5V and 3.3V Driver Driver Support Windows 98, Windows Millennium, Windows NT 4.0, Windows 2000, XP, Windows 2003, Netware 5.1, 6.0, 6.5, Red Hat Linux 8.0, 9.0, SuSE Linux 8.1, 8.2 and United Linux 1.0; Vxworks(optional charge) Load Type Air cooled mezzanine cards with faceplate I/O compatible; Air cooled host card and Conduction cooled host card with removable rib; Environmental Condition Operating Temperature Humidity Altitude Thermal Standards Industrial (-20 ~+70 ) Wide Temperature (-40 ~+85 ) 10% - 90% RH 12200m IEEE 1386-2001 风 冷 (Air Cooled) MIL-STD-810F\GJB150\GJB322A-98 Data Reliability ECC Life Reliability 12bit/512Byte 10Year@500GB/day SLC 3Year@500GB/day MLC Data Security RAID Configuration Data Destruction Keypoint (Destruct rate 5GB/s) Software RAID0 RAID1

MTBF 1,000,000 Hours *1 128GB Available @ Q3 2010 *2 256GB Available @ Q3 2010 *3 Typical values, the actual value associated with the test platform 2.2 Functional Diagram PMC solid state memory card has two main parts: PCI SATA-RAID controllers and two sets of SATA SSD. RAID Controller PCI industry protocol standard is compatible with 32bit 33MHz and 66MHz transmission mode, effectively compatible with a variety of computer platforms and operating systems, and can support two types of RAID configuration mode - RAID0 and RAID1. These two sets of SATA SSD controller manage the 16 NAND Flash, compatible with SLC and MLC type of card with a maximum total capacity of up to 512GB, and provides a fast data elimination function keys.

2.3 Functional Instructions 3.3V key hole Thermal side Fixed hole Destruction Switch LED2 LED1 Destruction Key LED3 LED4 Items Function Description LED1 Memory Card Reader Instructions Read/Write Indicator light operation

LED2 LED3 LED4 Destruction Switch SSD0 status indicator SSD0 status indicator Destruction Status Indicator Self-Destruction Switch Valid SSD0 for RAID configuration light status Valid SSD1 for RAID configuration light status If the destruction switch is ON, the indicator light will OFF and eliminate When the switch is ON, the destruction function is enabled When the switch is OFF, the destruction function is disabled Destruction Key Destruction trigger button Press the button to start the destruction function. 2.4 Destruction Function The Destruction controller will trigger the destruction function, this process will quickly clear all of the data stored in the flash devices. This can be performed to different type of data even confidential data and will not cause any damage to the SSD. This method is simple and effective. Destruction speeds is up to 5GB / s, and can be applied to various fields with data security requirements. Destruction Mode Operation: 1 Connect to a power supply, to make the board in a working condition; 2 Switch ON, to enable the destruction function LED4 will lit; 3 Press the destruction key for 1 second, and hold it for about a second; 4 As the memory card is in destruction state, it has a destruction rate of 5GB/s; 5 When the destruction function is completed, SSD0 and SSD1 already in non-partitioned condition;

2.4 Performance Table PMC memory card is working in 32bit 66MHz mode by making RAID0 configuration, has sustained read and write performance of up to 170MB/s (read) and 110MB/s (write). The following table shows a typical platform in the CPCIe sustained read and write 1 Type SSD0 Read/ Write Speed SSD1 Read / Write Speed RAID0 Read / Write Speed RAID1 Read / Write Speed 64GB SLC 117/74 117/74 177/117 117/59 128GB MLC 119/79 118/78 173/127 118/66 256GB MLC 118/75 118/75 173/127 118/66 32GB SLC 117/74 117/74 177/116 117/60 64GB MLC 118/78 118/77 177/127 118/66 128GB SLC 119/86 119/86 173/127 102/47 *1 The actual test performance application will vary with test platforms and number of boards. Test Platform Motherboard Chipset CPU Memory HBA Card Operating System Hardware Configuration Software Test Application Software Configuration NI PXIe-1062Q NI PXIE-8130 AMD Hammer DDR2 IML & nvidia nforce Pro3600 AMD TL-66 PC2-5300 DDR 1GB CPCIe HBA Card WindowsXP Using the memory card BIOS to configure the RAID ATTO Bench32 Using the memory card BIOS to configure the RAID

3. Installation Instruction 3.1 Hardware Installation 1 It depends on the application requirements, please select either XMC or PMC carrier board and must comply with the standard air-cooled heat dissipation structure in accordance to section 2.3 in providing heat in the cooling side of metal strips. CPCIe Carrier board as shown: 2 XMC or PMC memory card will be completely assembled in the right side direction of the carrier board, and fasten the screws.

3 Installing the card into the computer system 3.2 X86 Platform BIOS RAID Configuration In the X 86 platforms, you can manage and setup the RAID by using BIOS RAID tools. During system boot-up and loading of operating system, the following window will appear for about 5 seconds, and then press CTRL+S or F4 to enter BIOS RAID and configure the interface.

RAID configuration tool interface is divided into four parts with a command-line In the main menu (upper left corner) of this window you can select what is going to be implemented: Create RAID Set:will create a new RAID component or allocate new location to hard disk drive Delete RAID Set:will delete the RAID component or remove the location from hard drive Rebuild RAID 1 Set:after replacement of a hard drive, re-create RAID1 component Resolve Conflicts:after removing the hard disk, it will check for any errors in RAID

configuration drive ports, and RAID components will restore the normal working condition. Low Level Format:In removing a single hard drive does not format the hard drive nor allocate the remaining space. Logical Drive Info:it will show only the actual allocation of the buffer space of each RAID configuration information, and do not allocate the SATA adapter on the physical drive. Help section:in the upper right corner of the Help section, display context-sensitive help and status information. Physical Drive:Lower-left corner displays connection to the SATA adapter on the hard disk type and the capacity. Logical Drive:The lower right corner displays all hard drives connected to the controller Shows RAID components and JBOD hard drive under the system BIOS Spare hard disk, keeping the hard drive may lead to some conflict, and the BIOS may not recognize this as bad disk and it will be displayed at the bottom of this section. Useful command can be found at the bottom of the command line: Up and down arrows - to select a menu option or action ESC - back to the previous menu Enter to select any highlighted word Ctrl-E will exit configuration menu, depend on their operating condition. 3.3 Drivers Installation Please select the CD-ROM Driver according to the corresponding operating system. 3.4 Partition Configuration Based on RAID configuration and operating system, two completed SSD or two separate SSD can be identified after driver installation 1 In Windows and Linux operating system, it will only identify BIOS RAID configuration but in the case of no BIOS RAID acknowledged in the RAID configuration, it will be acknowledged as two separate storage devices.

2 In the Vxworks system, it will be acknowledged as two separate storage devices. In the case of two separate storage devices being acknowledged, it can use the software or operating system to provide the tools to acknowledged RAID0 (Stripe) or RAID1 (Mirror) operation, to increase the performance or security. IN addition, it can be partitioned of formatted based on the application requirements after the equipments acknowledged it. 3.5 Boot-up Configuration Memory card support the operating system to boot, the operating system installed can be used as guide for the memory card during the installation. 1. Computer boot-up, and enter the BIOS set-up. device. 2. Enter the BIOS boot option and set the memory card bootable

4. Selection Guide 4.1 Selection Table Products Model Type Interface Size Capacity Media Temperature Destruction PMC Memory Card RCH-I -P U3 64\28\56 -M 32\64\28 -S C\I\W I 4.2 Optional Accessories PCI to PMC Adaptor Model Standard Software PMCT2-V001 3.3V, 32bit, 66 MHz None Size

5. Caution 1 If the Destruction Function will not be used, place the switch into OFF-state to avoid it accidentally be switched.; 2 In inserting PMC carrier card to the memory card, please do not push it strong to avoid any damages on the connector; 3