Part H DIFFUSERS section 2 SEPT 2005. Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes

Similar documents
INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Grilles & Diffusers Series LFP Incorporating

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

DSRQ - DSRSQ - DSRSQ-THERM

Basic Selection & Proper Application of Overhead Air Distribution Devices

squrboxbox heat recovery squrboxbox I technical information

CONTENTS. Your Vent-Axia System Calculator. Page 3/4 What is Ventilation?

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

IDES-EDU. Educational Package Ventilation. Lecture 8: Sizing mechanical ventilation systems IEE/09/631/SI

sound reduction systems for commercial, educational and industrial environments

plenum slot diffusers

FIRE DAMPER APPLICATION GUIDE

Air-water systems for efficient air conditioning

AMD-33 Air Measuring Station with VCD-33 Control Damper

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

Airmanager Industrial HVAC retrofit results July Location Description:

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

HVAC Vents & Diffusers

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Exhaust Calculation Booklet

Combi Unit Genius. The energy efficient Building Service Centre

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

Basics of HVAC Cleaning

INNOVAIR Intelligent Fan Convectors IQL Controller SIZE 1 & 2 Units INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Innovair Size 1 & 2 IQL Units

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

How To Make A Supply Air Ceiling

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Supply air diffuser ROKA/RPKA

Decree of the Ministry of the Environment on fire safety of ventilation systems

DÜZ KANATLI KARE TAVAN ANEMOSTAD (BSCD) FLAT BLADE SQUARE CEILING DIFFUSER

Düz Kanatlý Kare Tavan Anemostad

ROR Trailer Products CS Air Suspension. choose for reliability... choose for quality... choose for robustness your profitability is our concern

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

BSK BSK DÜZ KANATLI KARE TAVAN ANEMOSTAD (BSCD) FLAT BLADE SQUARE CEILING DIFFUSER

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SERIES L. Fineline & Broadline. Linear Strip Grilles GRILLES 12

HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment

Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7

Acoustic Design Guide. NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices

security products metric sizes Redefine your comfort zone.

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Product Overview Benefits

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

Air-side Systems: Air Duct Design

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Diffractive Optical Elements (DOE) for FLEXPOINT Laser Modules

Rochdale Building Control Guide. Approved Document F Means of ventilation

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Experiment 3 Pipe Friction

TOP 10 NOISE CONTROL TECHNIQUES

DUCT SMOKE DETECTOR D4120

AMCA Publication (Rev )

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

SPECIAL APPLICATIONS

Installation and Operating Guide LOOVENT eco Centrifugal Fans (SELV versions)

Chapter 3.5: Fans and Blowers

Pizza! Pizza! Assessment

SBi 2013:12. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Zehnder Focus 200. Ventilation device

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Under sill units. Type FSL-B-ZAS

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Spetec. Laminar Flow Box. Portable Clean Room Technology

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

SECTION AIR INLETS AND OUTLETS

Optimum proportions for the design of suspension bridge

Fan Applications & System Guide

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

How To Factor By Gcf In Algebra 1.5

Manual piston sampler...m 11

Blast Resistant Building BP Refinery Rotterdam

APPLICATION NOTE PROFESSIONAL LOUDSPEAKERS BUILDING AN EFFECTIVE, HIGH PERFORMANCES, 2 WAY, 12 LOUDSPEAKER SYSTEM

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Cooktop Low-Profile Ventilation Hoods

PFT Two stage axial fan The high pressure fan for modern boiler plants

Fire. The Fire Installers Mate. A guide to fire alarm systems design

PART VIII: ABSORPTIVE SILENCER DESIGN

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

Unit 15: Measurement Length, Area and Volume

PUBLIC RESTROOMS, DESIGN INTENT

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

How To Test A Fume Cupboard

ISSUE A, MAY Mechanical Release Fire Smoke Dampers. Model Advanced Air

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps.

LIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE

- White Paper - Data Centre Cooling. Best Practice

Transcription:

Publication Part H DIFFUSES section 2 SEPT 5 Air Diffusers supply and exhaust ventilation systems plenum boxes

PLENUM BOXES introduction The general range of PB plenum boxes are manufactured with a return edge hem in the neck to suit the yoke strap fixings supplied with LCS, Flowline and F45L diffusers. The boxes can be manufactured to suit either top or side entry duct arrangements and are available with square rectangular or circular spigots. type PB options Optional spigot mounted flap dampers are available with either cord or quadrant operators. Plenums can also be supplied with a non fibrous fire resistant acoustic liner for applications with critical noise limits. plenum selection The plenum selection nomogram on page 20 is designed to optimise the cross sectional area of the box to ensure an even distribution of air along the length of the diffuser. To select an appropriate plenum size, firstly establish the static pressure loss of the diffuser at the required design duty from the appropriate performance table. Then, using the selection nomogram, project a line between the flow rate and pressure loss scales to the pivot line of the plenum dimension scale. From there, project a line from the appropriate diffuser slot width through the pivot point and read off the plenum height. Note, an allowance should be added to the height to allow for the depth of the diffuser frame refer to note on the plenum height scale. If the ceiling void height is limited, then any combination of width and height can be selected about the pivot point providing the plenum height can accommodate a suitable spigot size. To determine the spigot size, project a line from the flow rate scale through the required spigot air velocity to the diameter line. Square or rectangular spigots of equivalent area can also be selected using the spigot diameter as a pivot point. 2

PLENUM BOXES dimensions PBL W Top Entry (TE) PBH W L i/s *N 25 25 Side Entry (SE) D D B Dia D *H *H A *N *P i/s End Cap detail for single diffuser sections. *P - Neck dimension to suit diffuser type. See appropriate diffuser dimension table. *H - O/A Height including allowance for depth of diffuser. D *N - Flowline diffuser = 85mm LCS = 82mm F45L = 45mm D + Damper options FDC - Cord operated Flap FDQ - Quadrant operated Flap T Optional Acoustic Liner AL12 - T = 12mm AL25 - T = 25mm Allow for liner thickness when sizing plenum. ordering details EXAMPLE : type control option length width height spigot quantity PBH / FDQ / AL12 / 1 / 3F / 435 / 315SE / 4 3

SELECTION NOMOGAM SPIGOT DIAMETE 125 SPIGOT AI VELOCITY (m/s) APPOXIMATE N LEVEL (OPEN DAMPE) AI FLOW ATE l/s m 3 /hr GILLE PESSUE LOSS (Pa) WIDTH PLENUM DIMENSIONS PIVOT LINE HEIGHT 125 1 160 125 1 0 900 800 0 75 1F LCS1 75 700 2 0 2F LCS2 2 315 2 5 4 3 2 40 30 20 2 1 0 900 20 1 3F LCS3 4F LCS4 1 1 800 700 10 5 5F LCS5 6F LCS6 7F 8F 800 0 PIVOT LINE WIDTH HEIGHT ECTANGULA O SQUAE SPIGOT 4

PLENUM BOXES Select a suitable plenum size for a 1.2m long 3F diffuser supplying 270 l/s. Air flow rate (l/s/m) = 270/1.2 = 225l/s/m, which from the chart on page 11 gives pressure loss of 18Pa. example From the nomogram, an active plenum height of mm would be satisfactory with a mm x mm spigot, but to accommodate an equivalent size circular spigot the plenum height would need to be increased to 3mm. The overall plenum height with a circular spigot would therefore be 3 + 85 = 435mm. NOTE - to allow for the depth of the diffuser neck, add 85mm to the selected plenum height for Flowline and LCS slot diffusers, and mm for F45L louvre diffusers. note 5

Diffuser programme literature part A Introduction, Technical Overview and Selection Guide. part B Continuous Slot and Linear Louvre Diffusers. part C Multicore Square and ectangular Diffusers. part D Laminar Flow Panels. part E Circular Diffusers. part F Drum Jet Diffusers. part G Supply and Extract Valves. part H Plenum Boxes part I Finshes and Conversion factors JC House, Hurricane Way, Wickford Business Park, Wickford, Essex SS11 8YB, UK. Tel: +44 (0)1268 572266 Fax: +44 (0)1268 560606 email: info@brookeair.co.uk web: www.brookeair.co.uk