u n i v e r s a l c o m f o r t Designer of control solutions NA O7.124A
CONTROL ADAPTED TO THE ENTIRE RANGE V for Vision: Our range of CIAT controls features all the techniques used for air conditioning, heating and air-handling systems in office, hotel, residential and healthcare applications. We use our expertise to provide innovative and efficient solutions that provide unsurpassed comfort. FAN COIL UNITS CASSETTES DUCTABLE UNITS
A SOLUTION FOR EVERY TYPE OF LIVING AND WORKING SPACE V3000 KNX Networked PID ** control The excellence of networked systems > Networked system based on the KNX communications protocol (international standard). > Modulating control of valve(s) and electric heater (2-pipe/2-wire version). Automatic or manual control. > Selection of highly-intuitive controllers. > Radio-frequency remote control. V200 PI * Control Simplified performance The technology enables several units to be controlled with a single terminal (suites, conference rooms, landscaped offices, etc.). V30 Electronic On/Off control Individualised performance A single electronic terminal meeting all needs for individual control. High performance electronic control configurable using switches. Window contact for energy savings. Three manual fan speeds. Control on venting or on valve(s). RTR-E Electromechanical On/Off control Absolute simplicity The robustness of an electromechanical thermostat with three manual fan speeds. *PI: Proportional-Integral **PID: Proportional Integral Derivative
OPTIMISE COMFORT IN THE WO > Simplified access to master/slave function > Trouble-free operation > Optimum comfort V200 V30 > Easy to use > Functionalities suited to your needs > Innovative design Electronic controller with an innovative design allows individual control of any CIAT terminal unit. A single terminal for all your applications. Features switches for configuring and adjusting the device directly on site. On/off control of ventilation or valves with manual ventilation. Optimised energy savings: may be connected to a window contact or timer to switch to economy mode. Built-in algorithms for automatic control of thermo valves, electric heater, changeover sensor and return-air sensor. Available flush-mounted inside a sill terminal unit or as a wall-mounted version to be connected by an installer. PI electronic controller designed to automatically adjust comfort levels inside landscaped offices, conference rooms, etc. Comfort is automatically controlled by opening valves, triggering time-proportional operation of the electric heater, and adjusting the fan speeds. Independent loop: the master unit ensures smooth operation with the connected slave units. Single-zone control of up to 50 units. Optimised energy savings: dual economy and window contact. Factory settings that can easily be adjusted to specific needs (after analysis by our technical services).
RKPLACE GREATER ENERGY SAVINGS > Management of INDOOR AIR QUALITY and ENERGY SAVINGS for FRESH AIR V3000 KNX > The intelligence of networked systems > Intuitive room terminals with easy-access functions > CIAT's HEE concept: optimised energy savings Pack R1 for offices: fresh air supply controlled by an occupancy sensor Pack R+ for conference rooms: fresh air supply controlled by an air quality sensor (CO 2 ) that brings in the optimum amount of fresh air depending on the actual occupancy level. Networked PID control over the open KNX protocol (ISO 14543-3). Various highly intuitive terminals available with optional radiofrequency remote control. Select desired comfort levels with a single press of a button. Optimised energy savings of units through CIAT's HEE concept (High Energy Efficiency). Automatic management of ventilation as needed. The V3000 system continuously optimises settings by controlling the modulating valve(s) and electric heater to guarantee temperatures at selected levels all year round. Display of clogged filters for easier maintenance. Each operating mode is selected directly on the terminals: (automatic or manual fan speed, On/Off, setpoint adjustments, etc.) Adapts as your premises evolve: unit settings can be changed for easy reconfiguration of spaces. Master/slave control possible without a BAS. OPTION: Restricted supply-air temperature for optimised total comfort in all offices. V-LON LON bus communication Factory-wired controls with the LON communications protocol for office complexes equipped with this technology.
ENSURE YOUR CUSTOMERS WELL-BEING V30 > Trouble-free operation > A la carte comfort > Design blends in with any room RTR-E > Easy to operate > Robust Electromechanical controller available in a wall-mounted version to be connected by an installer Functions usable by room occupants On/Off button Three manual fan speeds Heating / cooling switch Temperature selection dial Temperatures adjustable from 5 C to 30 C Electronic control with innovative design controls any type of CIAT terminal unit destined for use in guest rooms. Room temperature selection dial A single design and a single terminal for all your applications. Features switches for configuring and adjusting the device directly on site On/off control of ventilation or valves with manual ventilation Optimised energy savings: controlled according to room occupancy Automatic control of the changeover sensor for heating / cooling only and a return-air sensor (if installed) May be adjusted to the return-air temperature of units Temperatures adjustable from 13 C to 29 C for greater energy savings V3000 > Intelligent communication > Easy to use > High-end solution with an unsurpassed design Networked PID control over the open KNX protocol (ISO 14543-3) Optimised energy savings of units through CIAT's HEE (High Energy Efficiency) concept The V3000 system continuously optimises settings by controlling the modulating valve(s) and electric heater to guarantee, all year round, temperatures at selected levels when rooms are occupied. Temperatures adjustable to fully meet your customers needs OPTION: Restricted supply-air temperature for optimised total comfort in all rooms
KEEP YOU HOME AT THE RIGHT TEMPERATURE Résidenciat > Flexible, trouble-free operation > Exclusive control for the Résidenciat system > Programmable operating times Control for the RÉSIDENCIAT all-in-one solution. Controls comfort inside living rooms and up to five other rooms (bedrooms, home office, dressing room, etc.). Programmable 7-day timer for managing changeovers to economy mode Main terminal in living room, zone terminals in other rooms Individual control of comfort-zone temperatures in each room V30 > Easy to use > Quality materials > All-season comfort Electronic control with an innovative design allows individual control of any CIAT terminal unit Available flush-mounted inside a terminal unit for a completely smooth look or as a wallmounted version to be connected by an installer On/off control of ventilation or valves with manual ventilation Optimised energy savings: may be connected to a window contact or timer to switch to economy mode.
CONTROL INDOOR AIR QUALITY V30 > Easy to use > Functionalities suited to your needs > Unobtrustive design Electronic control allows individual control of any CIAT terminal unit Designed specifically for comfort requirements in hospital rooms and adjoining areas A single terminal for all your applications Features switches for configuring and adjusting the device directly on site Optimised energy savings: may be connected to a window contact or timer to switch to economy mode Built-in algorithms for automatic control of thermo valves, electric heater, changeover sensor and return-air sensor On/off control of air or water circuit with manual ventilation Available flush-mounted inside a terminal unit for a completely smooth look or as a wall-mounted version to be connected by an installer V200 > Simplified access to master/slave function > Simplicity at your fingertips > Guaranteed comfort at all times PI electronic controller uses an independent loop to ensure comfortable conditions in reception areas, conference rooms, waiting rooms, emergency units, etc. Comfort is automatically controlled by opening valves, triggering time-proportional operation of the electric heater, and adjusting fan speeds. Independent loop: the master unit ensures smooth operation with the connected slave units. Optimised energy savings: dual economy and window contact. GREATER HYGIENE > Medical Comfort Concept Condensation-free control of terminal units - Condensation-free operation of terminal units for zero bacteriological risks - Optimises the energy efficiency of units and ensures that units operate at sensible capacity only.
V3000 > Intelligent networked system > Optimised control of energy savings: CIAT's HEE concept > Delivers the comfort required in hospital settings Look for the High Energy Efficiency label on CIAT components Linked with V3000 KNX communicative control, CIAT s HEE concept enables us to optimize the running of the terminal unit for energy savings, thereby limiting the impact of buildings on the environment. > KNX communication bus, the international ISO standard for technical control. > Modulating control via 0/10 V signal of Brushless system continually adapting fan speed (and therefore the electric power consumed) to the actual needs of the air conditioned premises. > CIAT's new brushless fan motor is up to 70% more energy efficient. > CIAT's new high-efficiency wheel is up to 20% more energy efficient. Networked PID control over the open KNX protocol (ISO 14543-3) Choice of various terminals with optional radiofrequency remote control for renovated facilities: no extra installation costs Optimised energy savings of units through CIAT's HEE concept (High Energy Efficiency) The V3000 system controls the modulating valve(s) or electric heater to keep settings at optimum levels. It ensures that hospital rooms remain at just the right temperature for patients. OPTION: Restricted supply-air temperature for optimised total comfort in all rooms. Energy savings with fresh air > PACK R1 Motorised fresh air damper controlled by an occupancy sensor draws in fresh air based on room occupancy levels. > PACK R+ Sensor measures the CO 2 level representative of the number of occupants in spaces such as conference rooms and waiting rooms in order to adjust the fresh air supply and achieve two crucial objectives: * Reduce energy consumption by conditioning fresh air at neutral temperature * Optimise the air quality in occupied spaces
CIAT'S CURRENT BATIBUS BAS RANGE... CIAT's BAS range with V2000 control TMF CO3 mini central control system V2000 terminal with display Major 2 Manages up to 72 terminal units equipped with V2000 control: The TMFC03 performs the following main BAS functions: - Programmable per zone operating times manage comfort and economy modes - Control of six independent zones with or without a master / slave loop - Setpoints adjustable for each zone and each operating mode - Two time-programmable On/Off outputs (optional): heat pump, extractor fan, etc. - Programmes can be saved to a smart card - Protected against power cuts - Operation of electric heater controlled by the outdoor temperature V2000 terminal for hotels Major 2 NCHY CMF300 central control system CMF 300 Remote management via modem for one or more users Bus line Melody Coadis 2 Windows-compatible CMF 300 control system Interface Modbus / Jbus Manages up to 300 terminal units equipped with V2000 control - Programmable operating times, setpoint adjustments - Intuitive display continuously shows building layouts copied from architectural drawings - Remote management allows the system to be accessed via modem - Temperature history (spaces, setpoints) displayable on screen or printable in colour for analysis and optimisation of all spaces - Possibilities: > 1 Batibus/Jbus interface for Water chiller/atu > Up to 32 status or fault inputs > Up to 16 timed On/Off outputs Bus power supply PowerCIAT water chiller
...NEW: KNX KNX BUS V 3000 The EIB and EHS Batibus protocols have been merged to create KNX Benefit from the best Batibus, EHS and EIB have to offer - An ISO-certified European solution for worldwide use - A single open protocol - Multimedia (twisted pair, radio-frequency, etc.) - Interoperable - Compatible with current products V 3000 control with native KNX connectivity Optimise your buildings - A communications protocol for all building constraints - Adopted by manufacturers - Freedom of choice for applications - Commitment by manufacturers to standardise their applications and make their products interchangeable - Royalty-free use Positioning compared to other media SUPERVISION Ethernet - TCP/IP AUTOMATION BACnet FIELD Large buildings > 10,000 m2 Medium buildings between 3,000 and 10,000 m2 Small buildings < 3 000 m² Houses CIAT is an active member of the association of manufacturers for the promotion of KNX solutions. Look for us on www.knx.fr, where you will also find all KNX-based building automation solutions offered by member manufacturers and information on this new communication bus.
Our reference is your comfort BP 14-01350 CULOZ - FRANCE Tel.: + 33 (0)4 79 42 42 42 info@ciat.fr - www.ciat.com This document is not contractually binding CIAT reserves the right to modify or improve its products without notice - Photo credits: CIAT, Lenox and PhotoAlto (Eric Audras)