Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course



Similar documents
Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Water Pump Replacement

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Evaluate, Clean, and Tune Guidance

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

Type K current limiting fuse canister Technical information and installation guide

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Air Conditioning Sign-Off Sheet

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

13. REAR WHEEL/BRAKE/SUSPENSION

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Oil and Coolant Circulating Heating System. Model - OCSM

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

AC Electric Motors best practice

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

CEILING CASSETTE FAN COIL UNIT

Easy Tool Retracting System CMC-SR2159ER36

Turbocharger system components, servicing

Applying Basic Electricity Principles to Service Propane Appliances (Updated 11/2012) Performance-Based Skills Assessment Evaluation Packet

Electronic Power Control

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Type MG-6 Multi-Contact Auxiliary Relay

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

UNIVERSAL 1550 PRE-MIX DISPENSER

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Transformer oil cooler ALFA A02

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

The Intelligent AX1 Switchgear for Medium Voltage

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Volume. HOMEWOOD PRODUCTS CORPORATION Westinghouse Technology. CA Breaker Instruction Manual

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

AXLE SHAFTS - FRONT Toyota Celica DESCRIPTION REMOVAL, DISASSEMBLY, REASSEMBLY & INSTALLATION DRIVE AXLES Toyota FWD Axle Shafts

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Attachment J-C18.1. HVAC Work Instructions

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

2003 ACCORD - Automatic Transmission Removal

RAY-MAX Integrated Solar Power Strip

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Super Cascade Filtration Systems (CE)

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Munchkin Heat Exchanger Maintenance

Asset Monitoring Solutions Integrated monitoring packages for a smarter, more reliable power grid

Cooling system components, removing and installing

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SL280UHV SERIES GAS FURNACE WARNING

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Type: DILM32 10(24V50HZ) Article No.:

INSTALLATION MANUAL E N G L I S H E-II-YDFC-0907 DIGITAL SCROLL SERIES AIR-CONDITIONER CEILING AND FLOOR TYPE

Diesel Engine Driven Generators Page 1 of 6

E2 Series Electric Furnaces

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Class 5 to 7 Truck and Bus Hydraulic Brake System

TS93 EMR T/PT/TDE. Surface applied door closer

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Aquamax Australia Pty Ltd ABN

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

2005 MINI Cooper MANUAL TRANSMISSIONS On-Vehicle Servicing. Cooper S Getrag 285

REMOVAL AND INSTALLATION

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

Type: DILM9 10(24VDC) Article No.:

SALVAGING FLOOD DAMAGED ELECTRICAL EQUIPMENT

SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management Ver. 1

When looking at machine tools, the details of the installed drive technology usually

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Circuit Breakers. NRC Series. NRC Series

Transcription:

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course description HPL 72,5-300 B1 with BLG1002A Level A & B

Training course description HPL 72,5-300 B1 with BLG1002A Duration 2 days(10 hour working day) Maximum participants 6 Price This training shall enable the trainee to Included subjects Tools/equipment used Documentation used and distributed Pre-requisitions Conditions for confirmation of participation: 17 000:-/ attendee - Know the HPL B1 circuit breaker range. - For the above stated breaker type: - Understand the design, operation and function and adhering components. - Perform installation & pre-comissioning. - Understand the lifespan of a circuit breaker - Know about and how to perform the required periodic,preventive maintenance and condition assessments - Safety - Design, function and mode of operation. - Description of circuit breaker lifespan. - Training in installation & pre-commissioning - Training in periodic and preventive maintenance - Practical exercises Focus of the training is hands-on exercises - Standard toolbox - Gas filling equipment, Gas reclaiming system, Gas analyzing equipment, Gas leakage detector - Breaker analyzer system SA10 - Laptop computer - Product documentation - Leaflets - Confirmation of participation - Knowledge in English, reading and writing -Electromechanical education - Basic computer use - Written examination - Assessment of factory supervisor February 6, 2013 Slide 2

HPL 72,5-300 B1 with BLG1002A Scope of training program, competence level A Steps Installation & pre-commissioning Competence level A Pole beam and support Assembly Fitting the circuit breaker pole and protective tubes. Installation of operating mechanism Final assembly of the circuit breaker pole. Fitting of rod system Assembly of gas monitoring system Electrical connections Pressurizing of circuit-breaker poles Inspection of bolt joints Assembling the indicator sign and cover Inspection prior to commissioning Pre-commissioning check list Circuit breaker Periodic maintenance Competence level A External cleanliness Heating element function Gas pressure Valves and draining holes Lubrication Note!!! Safety and preparations are always included February 6, 2013 Slide 3

HPL 72,5-300 B1 with BLG1002A Scope of training program, competence level B Preventive maintenance and condition assessment Competence level B Preventive maintenence and condition assessment Competence level B Circuit breaker Operating mechanism Rating plates Operation counter SF 6 gas Porcelain insulators Composite insulators External cleanliness Gas pressure Valves and draining holes Bolts and nuts Heating element function Oil leakages from damper Note serial number s Note the number of operations Gas level (filling ifnecessary) Dew point, for normal gas pressure in the circuit breaker. Cleanliness Bolts and nuts Damages Function times Availability Motor current Latch device Coils Limit switch Opening time Closing time Close-Open time Deviations between phases Auxiliary switch Travel curve Contact damping Rod system Control safety Anti-pumping relay Motor current Visual inspection of settings Function control Coil resistance and current Main circuit Mechanism -Resistance measurement Resistance bridge, using a test current of 200-400 ADC Reference hole in outer lever and mechanism housing. Heating element Central control cabinet (if applicable) Note!!! Safety and preparations are always included Resistance measurement Resistance measurement February 6, 2013 Slide 4

HPL 72,5-300 B1 with BLG1002A Scope of training program, competence level B Preventive maintenance and condition assessment Competence level B Thermostat (if applicable) Terminal blocks Adjusted value Bolts and clamps Protective motor switch Seals/SF6 gas Blocking relays Corrosion Lubrication Tightening torque Operation Signal for voltage drop Density monitoring Relays Operating mechanism Latches Worm gear All bolt joints Operation Operating time measurement Note!!! Safety and preparations are always included February 6, 2013 Slide 5