Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Version 1.0



Similar documents
BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Release Supplement 1/10Gb Uplink Ethernet Switch Module Version 6.7

How To Install An At-S100 (Geo) On A Network Card (Geoswitch)

IBM Networking OS. Release Notes. for the IBM Flex System EN2092 1Gb Ethernet Scalable Switch

20 GE + 4 GE Combo SFP G Slots L3 Managed Stackable Switch

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

AT-S95 Version AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

AT-S41 Version Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes

Release Notes TM. BLADEHarmony Manager Version 3.2. Part Number: BMD00093, July 2009

ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

AT-S45 Version Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Ethernet Link SGI-4844F

AT-S105 Version Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches

Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide

Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version Rev. B

Command Reference. Alteon OS Layer 2-7 GbE Switch Module for IBM BladeCenter

AlliedWare Plus Version AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes

Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M

Ethernet Link SGI-2424

Layer 3 Network + Dedicated Internet Connectivity

AT-S63 Version Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes

AT-S62 and AT-S62 NE Version Management Software for AT-8500 Series Switches Software Release Notes

AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [ ] Gigabit Ethernet Smart Switch Rev A

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

PRODUCT DETAILS 3Com Switch 4500 Family 1 de 9 03/03/2008 9:43

LotWan Appliance User Guide USER GUIDE

AT-S63 and AT-S63 NE Version Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

Chapter 2 Quality of Service (QoS)

SonicOS Enhanced Release Notes

Switch Quick Configuration CLI Guide for

AT-S84 Version ( ) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes

LifeSize Video Communications Systems Administrator Guide

DCS C Fast Ethernet Intelligent Access Switch Datasheet

EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW

ADMINISTRATION GUIDE Cisco Small Business

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E.

DCS CT-POE fully loaded AT PoE Switch Datasheet

TP-LINK L2 Managed Switch

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Command Reference. Alteon OS Great America Parkway Santa Clara, CA Reference: B

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

High Performance 10Gigabit Ethernet Switch

4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0

OLT LTP-8X_v Appendix to Operation Manual OLT LTP-8X Quick Configuration Guide Central Office Node Terminal

TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ.

ProSafe Plus Switch Utility

Advanced Traffic Management Guide. ProCurve Switches Q.10.XX.

management and configuration guide hp procurve series 2500 switches

BLADE PVST+ Spanning Tree and Interoperability with Cisco

Securing Networks with PIX and ASA

ADMINISTRATION GUIDE Cisco Small Business

ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide

ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement

1 Data information is sent onto the network cable using which of the following? A Communication protocol B Data packet

ENTERASYS WEBVIEW WEB-BASED MANAGEMENT FOR THE VH-2402S/VH-2402S2 WEB MANAGEMENT GUIDE

20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W

24 GE + 2 GE SFP L2 Managed Switch

Cisco Small Business Managed Switches

WSG24POE Switch. User Manual

Cisco Small Business Managed Switches

Command Line User s Guide

AT-S39 Version Management Software for the AT-8000 Series Fast Ethernet Switches. Software Release Notes

Easy Smart Configuration Utility

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG

How To Configure Voice Vlan On An Ip Phone

Unified Access Point Administrator's Guide

Alteon Basic Firewall Load Balancing. Sample Configuration

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P.

ProCurve Switch ProCurve Switch

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

netis Web Management Switch User's Guide Manual Version:1.1:

ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch

TP-LINK. Gigabit L2 Managed Switch. Overview. Datasheet TL-SG3216 / TL-SG

Switch Web GUI Quick Configuration Guide for

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

P330-ML Version 4.5 Release Notes

SuperStack 3 Switch 4400 Software Version 3.00 Release Notes

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

SUPERSTACK 3 SWITCH 4200 SERIES MANAGEMENT QUICK REFERENCE GUIDE

Industry-based CLI (Cisco like) and Networking OS graphical user interface

6.0. Getting Started Guide

Firewall VPN Router. Quick Installation Guide M73-APO09-380

WatchGuard SSL v3.2 Update 1 Release Notes. Introduction. Windows 8 and 64-bit Internet Explorer Support. Supported Devices SSL 100 and 560

Cisco SFE1000P 8-Port 10/100 Ethernet Switch: PoE/Fanless Cisco Small Business Managed Switches

Chapter 4 Rate Limiting

ProSAFE 8-Port and 16-Port Gigabit Click Switch

Innominate mguard Version 6

Lab Organizing CCENT Objectives by OSI Layer

GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Chapter 3 Management. Remote Management

CCT vs. CCENT Skill Set Comparison

Transcription:

Alteon OS Release Notes Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Version 1.0 Part Number: 31R1724, June 2006 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net

Copyright 2006 Blade Network Technologies, Inc., 2350 Mission College Blvd. Suite 600, Santa Clara, California, 95054, USA. All rights reserved. Reference number: 31R1724 This document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this document may be reproduced in any form by any means without prior written authorization of Blade Network Technologies, Inc. Documentation is provided as is without warranty of any kind, either express or implied, including any kind of implied or express warranty of non-infringement or the implied warranties of merchantability or fitness for a particular purpose. U.S. Government End Users: This document is provided with a commercial item as defined by FAR 2.101 (Oct. 1995) and contains commercial technical data and commercial software documentation as those terms are used in FAR 12.211-12.212 (Oct. 1995). Government End Users are authorized to use this documentation only in accordance with those rights and restrictions set forth herein, consistent with FAR 12.211-12.212 (Oct. 1995), DFARS 227.7202 (JUN 1995) and DFARS 252.227-7015 (Nov. 1995). Blade Network Technologies, Inc. reserves the right to change any products described herein at any time, and without notice. Blade Network Technologies, Inc. assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by Blade Network Technologies, Inc. The use and purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of Blade Network Technologies, Inc. Alteon, Alteon WebSystems, and Alteon OS are trademarks of Nortel Networks, Inc. in the United States and certain other countries. Any other trademarks appearing in this manual are owned by their respective companies. Originated in the USA. 2 31R1724, June 2006

Release Notes The Nortel 10Gb Uplink Ethernet Switch Module (GbESM) is one of up to four GbESMs that can be installed in the IBM BladeCenter chassis. These release notes provide the latest information regarding Alteon OS for Nortel 10Gb Uplink Ethernet Switch Module version 1.0. This supplement modifies information found in the complete documentation: Alteon OS Application Guide for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Alteon OS Command Reference for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Alteon OS NNCLI Reference for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Alteon OS Browser-Based Interface for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter BladeCenter Installation and User s Guide for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter The publications listed above are available from the IBM support website: http://www.ibm.com/support Please keep these release notes with your product manuals. 31R1724, June 2006 3

Hardware support This Alteon OS version 1.0 software is supported only on the IBM BladeCenter s 10Gb Uplink Ethernet Switch Module (GbESM). The Nortel GbESM is a high performance Layer 2-3 embedded network switch that features tight integration with IBM BladeCenter s management module. The GbESM has three 10Gbps external ports (see Figure 1). The number and type of ports are as follows: Two 10GBASE-CX4 connectors One 10Gbps XFP (LC connector) One 100/1000T external SFP uplink (RJ45) Fourteen 10/100/1000 Ethernet internal ports. RS-232 serial console port RS232 LINK 1 TX/RX LINK 2 TX/RX LINK 3 TX/RX LINK 4 TX/RX 10GBASE-CX4 connectors 3 10 Gbps XFP (LC) 4 100/1000Mbps SFP uplink (RJ45) Figure 1 GbESM Faceplate 4 31R1724, June 2006

Updating the Switch Software Image The switch software image is the executable code running on the GbE Switch Module. A version of the image ships with the switch, and comes pre-installed on the device. As new versions of the image are released, you can upgrade the software running on your switch. To get the latest version of software available for your GbE Switch Module, go to: http://www.ibm.com/pc/support Click on software updates. Use the /boot/cur command to determine the current software version. The typical upgrade process for the software image consists of the following steps: Place the new image onto a FTP or TFTP server on your network, or on a local computer. Transfer the new image to your switch. Select the new software image to be loaded into switch memory the next time the switch is reset. Loading New Software to Your Switch The switch can store up to two different software images, called image1 and image2, as well as boot software, called boot. When you load new software, you must specify where it should be placed: either into image1, image2, or boot. For example, if your active image is currently loaded into image1, you would probably load the new image software into image2. This lets you test the new software and reload the original active image (stored in image1), if needed. To download a new software image to your switch, you will need the following: The image or boot software loaded on a FTP or TFTP server on your network The hostname or IP address of the FTP or TFTP server The name of the new software image or boot file NOTE The DNS parameters must be configured if specifying hostnames. 31R1724, June 2006 5

Image names: Image file: GbESM-10U-AOS-1.0.1.1_OS.img Boot file: GbESM-10U-AOS-1.0.1.1_Boot.img When the above requirements are met, use the following procedure to download the new software to your switch. NOTE When performing this update, make sure you download the new boot file and the new image file. 1. At the Boot Options# prompt, enter: Boot Options# gtimg 2. Enter the name of the switch software to be replaced: Enter name of switch software image to be replaced ["image1"/"image2"/"boot"]: <image> 3. Enter the hostname or IP address of the FTP or TFTP server. Enter hostname or IP address of FTP/TFTP server: <name or IP address> 4. Enter the name of the new software file on the server. Enter name of file on FTP/TFTP server: <filename> The exact form of the name will vary by server. However, the file location is normally relative to the FTP or TFTP directory (usually /tftpboot). 5. Enter your username for the server, if applicable. Enter username for FTP server or hit return for TFTP server: <username> or <Enter> 6. The system prompts you to confirm your request. You should next select a software image to run, as described below. 6 31R1724, June 2006

Selecting a Software Image to Run You can select which OS software image (image1 or image2) you want to run in switch memory for the next reboot. 1. At the Boot Options# prompt, enter: Boot Options# image 2. Enter the name of the image you want the switch to use upon the next boot. The system informs you of which image is currently set to be loaded at the next reset, and prompts you to enter a new choice: Currently set to use switch software "image1" on next reset. Specify new image to use on next reset ["image1"/"image2"]: 31R1724, June 2006 7

New Software features The list of features below briefly summarizes the new functionality of the 10Gb Uplink Ethernet Switch Module (GbESM). For more detailed information about configuring GbESM features and capabilities, please refer to the Alteon OS Application Guide for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter. Nortel Networks Command Line Interface The Nortel Networks command line interface (NNCLI) provides an industry standard interface for monitoring and configuring the GbESM. Users can toggle between the Alteon OS CLI and the NNCLI. To learn the basic structure and operation of the NNCLI, refer to Alteon OS NNCLI Reference for the Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter This reference guide lists the NNCLI commands, and describes the function of each command. LDAP Authentication and Authorization Alteon OS supports the LDAP (Lightweight Directory Access Protocol) method to authenticate and authorize remote administrators to manage the switch. LDAP is based on a client/ server model. The switch acts as a client to the LDAP server. A remote user (the remote administrator) interacts only with the switch, not the back-end server and database. LDAP authentication consists of the following components: A protocol with a frame format that utilizes TCP over IP A centralized server that stores all the user authorization information A client, in this case, the switch Protocol-Based VLANS Protocol-based VLANs (PVLANs) allow you to segment network traffic according to the network protocols in use. Traffic generated by supported network protocols can be confined to a particular VLAN. You can give different priority levels to traffic generated by different network protocols. With PVLAN, the switch classifies incoming packets by Ethernet protocol of the packets, not by the configuration of the ingress port. When an untagged or priority-tagged frame arrives at an ingress port, the protocol information carried in the frame is used to determine a VLAN to which the frame belongs. When a tagged frame arrives, the VLAN ID in the frame s tag is used. 8 31R1724, June 2006

ACL Groups Access Control Lists (ACLs) allow you to classify packets according to a particular content in the packet header, such as the source address, destination address, source port number, destination port number, and others. Packet classifiers identify flows for more processing. You can define a traffic profile by compiling a number of ACLs into an ACL Group, and assigning the ACL Group to a port. Each port can accept up to 127 filters, including ACL Groups. Each ACL in an ACL Group has a precedence level, based on its position in the ACL Group. The first ACL added to the ACL Group has the highest precedence, the last ACL added has the lowest precedence (top to bottom). If a packet matches the highest precedence ACL, the following ACLs are also considered, in order of precedence. IGMP Static Multicast Router A static multicast router (Mrouter) can be configured for a particular port on a particular VLAN. A static MRouter does not have to be learned through IGMP Snooping. A total of 16 static Mrouters can be configured on the GbESM. Both internal and external ports can accept a static Mrouter. When you configure a static Mrouter on a VLAN, it replaces any dynamic Mrouters learned through IGMP Snooping. IGMP Relay The GbESM can act as an IGMP Relay (or IGMP Proxy) device that relays IGMP multicast messages and traffic between an Mrouter and end stations. IGMP Relay allows the GbESM to participate in network multicasts with no configuration of the various multicast routing protocols, so you can deploy it in the network with minimal effort. 31R1724, June 2006 9

Supplemental Information This section provides additional information about configuring and operating the GbESM and Alteon OS, version 1.0. Management Module The Fast POST=Disabled/Enabled inside the IBM management module Web interface I/O Module Admin Power/Restart does not apply to the GbESM. Solution: To boot with Fast or Extended POST, go to the I/O Module Admin Power/ Restart window. Select the GbESM, and then choose Restart Module and Run Standard Diagnostics or Restart Module and Run Extended Diagnostics. The following table correlates the Firmware Type listed in the IBM management module s Web interface Firmware VPD window to the GbESM software version: Table 1 Firmware Type list Firmware Type Boot ROM Main Application 1 Main Application 2 Description GbESM Boot code version Image 1 GbESM Alteon OS version Image 2 GbESM Alteon OS version Within the IBM management module Web interface, the Java applets of Start Telnet Session and Start Web Session do not support changing of default known ports 23 and 80 respectively. Solution: If the Telnet or HTTP port on the GbESM is changed to something other than the default port number, the user must use a separate Telnet client or Web browser that supports specifying a non-default port to start a session to the GbESM user interface. Management Module-GbE Switch Module Connectivity Currently, the IBM management module is designed to provide one-way control of the GbESM. As a result, the GbESM may lose connectivity to the management module via the management port under the following conditions: If new IP attributes are pushed from the management module to the GbESM while the IP Routing table is full with 2048 entries, the new attributes will not be applied. 10 31R1724, June 2006

Solution: Enable External Management over all ports, connect to the switch using other interface and then clear the routing table. Then push the IP address from the management module. If this does not work, use Solution 2 below. If you execute the /boot/reset CLI command on the GbESM or the GbESM resets itself, the management module might not push the IP attributes to the switch, and connectivity may be lost. Solution 1: If you should experience any connectivity issues between the switch module and the management module, go to the I/O Module Configuration window on the management module s Web interface. Under the New Static IP Configuration section, click Save to trigger the management module to push the stored IP attributes to the switch module. Solution 2: If Solution 1 does not resolve your connectivity issue, then go to the I/O Module Admin/Power/Restart window on the management module s Web interface. Restart the switch module in question. Solution 3: If this still does not resolve the issue, enable Preserve new IP configuration on all resets setting on the management module and restart the switch module via the I/O Module Admin/Power/Restart window on the management module s Web interface. NOTE As a rule, always use the management module Web interface to change the GbESM management IP attributes (IP address, mask and gateway), and then click Save to push the IP attributes to the switch module. Use of the command-line interface to change the switch module management IP attributes may result in duplicated IP Interface 128 entries in the GbE Switch route table and/or loss of connectivity via the management module. Management Port Nomenclature Support for both management modules is included within a single management port (MGT). The MGT port dynamically connects to the active management module. This yields configuration and display characteristics that are different from predecessor Nortel GbE switch modules, but the functionality is equivalent. 31R1724, June 2006 11

Secure Management Network The following GbESM attributes are reserved to provide secure management access to and from the IBM management module: VLAN 4095 IP Interface 128 Gateway 132 MGT (Port 15) STG 32 For more information about remotely managing the GbESM through the external ports, see Accessing the Switch in the Alteon OS Version 1.0 Application Guide. NOTE The external uplink ports (EXT1-EXT4) cannot be members of the management VLAN (4095). Secure Shell (SSH) Because SSH key generation is CPU intensive, the GbESM attempts to avoid unnecessary key generation. The process generates three server keys: 1. One key is generated to replace the current server key, if used. 2. A second key is generated as a spare, in case the current server key is used and the specified interval expires. 3. A third key is generated for use at the next reboot. Therefore, if you never login via SSH, you will only see two key generation events. You may see all three events directly following a reboot. If you want to witness the key generation after the specified interval has expired, then you must login via SSH at least once during each expiration interval. 12 31R1724, June 2006

Trunk Group Configuration Tips Please be aware of the following information when you configure trunk groups: Always configure trunk groups first on both ends, before you physically connect the links. Configure all ports in a trunk group to the same speed. You cannot aggregate Gigabit ports with 10GBASE-CX ports. Spanning Tree Configuration Tips To ensure proper operation with switches that use Cisco Per VLAN Spanning Tree (PVST+), you must do one of the following: Create a separate Spanning Tree Group for each VLAN. Manually add all associated VLANs into a single Spanning Tree Group. When using Layer 2 Trunk Failover, disable Spanning Tree Protocol on external ports. Syslog Configuration Tip The facility parameter traditionally is used to correlate services (e.g. IP, CLI, etc.) to messages. This is done to distinguish between the different services that are running in the network/ device. However, for the GbESM, there is a single configured facility value (0-7) used on all messages. By configuring a unique facility value for each switch, a single SYSLOG server can distinguish between the various GbESMs in the network. Refer to System Host Log Configuration in the Alteon OS Version 1.0 Command Reference. 31R1724, June 2006 13

Known issues This section describes known issues for the GbESM and Alteon OS. ACL Filtering When an ACL is installed on two different ports, only one statistics counter will be available. The GbESM does not support two different statistics counter for one ACL installed on two different ports. (Hardware Limitation) When setting up an ACL to set 802.1p priority for in-profile packets, and updating DSCP field using TOS bits for out-of-profile packets, the out-of-profile packets will have also the 802.1p priority set based on the in-profile setting. (Hardware limitation) Although the management port can be configured for port filtering, actual port filtering will not occur, because the system filters out the management VLAN. IGMP relay When having joins from multiple VLAN's and the Multicast data Transmitter is on a VLAN that did not receive any joins, multicast data is routed only if the flood option is disabled using the command, /cfg/l3/igmp/adv/flood d. If an IGMP v2 joins an IGMP group on the same port where a v1 join has already been issued, the software will default to the v1 timeout value. Interoperability with Older Hubs The command-line interface might display link up and link down messages continuously for an external port that is connected to certain older hub models configured for 100 Mbps halfduplex. The display might show link up erroneously. This behavior has been observed when connecting the GbESM with the following devices: NETGEAR FE104 100 hub SBS 1000Base-T NIC 3Com Linkbuilder FMS100 Hub 3C250 TX/I 3Com SuperStack II 100TX 3C250C-TX-24/12 Nortel Baystack 204 Hub If the GbESM is connected to an Alteon Application Switch which requires a link speed of 100 Mbps half-duplex, then enable auto negotiation on the GbESM port with port speed=any, mode=any, fctl=both, and auto=on. 14 31R1724, June 2006

SNMP Link States Each port is capable of generating a LinkStateUp and LinkStateDown trap. This capability is enabled or disabled using the linktrap parameter, using the CLI command, /cfg/sys/ssnmp/linkt. LinkState traps are enabled by default. In this release of the software, when a user attempts to disable LinkState traps (/cfg/sys/ssnmp/linkt <port #> d), then applies and saves the configuration, an entry will be written incorrectly to the configuration file. Rather than writing the tree path /cfg/sys/ssnmp, the path / cfg/ssnmp will be saved, resulting in two behaviors: On next reset, the GbESM will report an error; specifically Error: unknown command "ssnmp" Since the parameter change is not recognized, linkt will remain enabled. Solution: Manually edit the configuration file. The configuration file can be written to, and read from a TFTP server. Start a TFTP server, then use the Switch Module command /cfg/ptcfg to write the configuration file to the device where the TFTP server is operating. Open the file with an ASCII text editor, locate the line starting with: /cfg/ssnmp/linkt Change this line to: /cfg/sys/ssnmp/linkt Write the change to the cfg file, then use the command /cfg/gtcfg to read the file back to the GbESM. Now reset the GbESM. The link state (/info/link) infrequently may report link up status for a server blade that has been removed from the chassis. Solution: Disable internal ports for empty server blade slots. 31R1724, June 2006 15

Link Aggregation Control Protocol If a static trunk on a GbESM is connected to another GbESM with LACP configured (but no active LACP trunk), the command /info/l2/trunk might erroneously report the static trunk as forwarding. Since LACP trunks use LACPDU packet to maintain trunking with the partner, there is a possibility for those packets to be dropped from an extremely busy trunk. If this happens, some links in the LACP trunk might be removed, then aggregated back to the trunk if an LACPDU is received. To avoid this unstable LACP trunk link, you can add more links to the trunk to increase the bandwidth, or use regular static trunk if there are no more links available. Linking at 10/100Mb When the link speed for an external connection is forced (i.e. no Auto-Negotiation) to 100 Mbps and then changed to 10 Mbps, if the external device is changed first, the external device may erroneously report the link as DOWN even after the GbESM is changed to 10 Mbps. Solution: At the external device, disconnect and reconnect the cable. Static MRouter If a port has a static multicast router (MRouter) configured, and you move the port to a different VLAN, the static MRouter appears in the /info/l3/igmp/mrouter/dump output for the original VLAN. Solution: When you move the port to a new VLAN, remove the static MRouter from the port, and add it again. ACL Filters The ACL filters for TCP/UDP work properly only on packets that do not have IP options. QoS Metering Traffic may exceed the configured maximum burst size of the ACL meter (/cfg/port x/aclqos/meter/mbsize) by one packet, with that packet remaining In- Profile. Once the ACL meter has been exceeded, additional burst packets fall Out-of-Profile. QoS and Trunking When you assign an ACL (or ACL Group) to one port in a trunk, Alteon OS does not automatically assign the ACL to other ports in the trunk, and it does not prompt you to assign the ACL to other ports in the trunk. Solution: Manually assign each ACL or ACL Group to all ports in a trunk. 16 31R1724, June 2006

RADIUS with SSHv2 With RADIUS turned on, users might see a duplicate login prompt for SSHv2 clients, if the RADIUS server is too slow to respond or if the RADIUS server is not available. In this case, users must re-type the username and password to login. RIP MIBs Due to backward-compatibility issues, two Routing Information Protocol (RIP) MIBs are available in Alteon OS : ripcfg and rip2cfg. Use the rip2cfg MIB to configure RIPv1 and RIPv2 through SNMP. Alteon OS does not support the standard RIPv2 MIB, as described in RFC 1724. Use the rip2cfg MIB to configure RIPv1 and RIPv2 through SNMP. Trunk and Link Loop When you create a trunk or link loop between the GbESM and another switch, packets might loop infinitely at line rate within the related links. When this problem occurs, the GbESM continuously displays the following messages at the console: WARNING: packet_sent u: 0, dv_active: tx ring full packet_sent dcnt=114, public1=110, vcnt=1025 Solution: Remove the loop to resolve this misconfiguration. Trunk Traffic Multicast, broadcast and DLF (Destination Lookup Failed, which are unknown destination MAC packets) traffic is sent to the lowest numbered port in the trunk. If this port is down, then the traffic is sent to the next lowest-numbered port. If the port that was down comes up again, the traffic is not re-hashed back to the recovered port. 31R1724, June 2006 17

Browser Based Interface Users with Operator privileges may not make any changes to switch configuration in the BBI. Some versions of Microsoft Internet Explorer version 6.x do not perform HTTP download efficiently. If you have one of these versions, HTTP software download might take much longer than expected (up to several minutes). Blade Network Technologies recommends the Mozilla Firefox browser for BBI use. 18 31R1724, June 2006