Release Supplement 1/10Gb Uplink Ethernet Switch Module Version 6.7
|
|
|
- Kenneth Neil Wilcox
- 9 years ago
- Views:
Transcription
1 BLADEOS Release Supplement 1/10Gb Uplink Ethernet Switch Module Version 6.7 Part Number: BMD00276-A, August Mission College Blvd. Santa Clara, CA
2 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Copyright 2011 BLADE Network Technologies, an IBM company, 2051 Mission College Blvd., Santa Clara, California, 95054, USA. All rights reserved. Reference number: BMD00276-A Copyright IBM Corporation US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. This document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this document may be reproduced in any form by any means without prior written authorization of BLADE Network Technologies. Documentation is provided as is without warranty of any kind, either express or implied, including any kind of implied or express warranty of non-infringement or the implied warranties of merchantability or fitness for a particular purpose. U.S. Government End Users: This document is provided with a commercial item as defined by FAR (Oct. 1995) and contains commercial technical data and commercial software documentation as those terms are used in FAR (Oct. 1995). Government End Users are authorized to use this documentation only in accordance with those rights and restrictions set forth herein, consistent with FAR (Oct. 1995), DFARS (JUN 1995) and DFARS (Nov. 1995). BLADE Network Technologies reserves the right to change any products described herein at any time, and without notice. BLADE Network Technologies assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by BLADE Network Technologies. The use and purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of BLADE Network Technologies. BLADE Network Technologies, the BLADE logo, BLADEHarmony, BNT, NMotion, RackSwitch, Rackonomics, RackSwitch Solution Partner, ServerMobility, SmartConnect and VMready are trademarks of BLADE Network Technologies. All other names or marks are property of their respective owners. Originated in the USA. 2 BMD00276-A, August 2011
3 Release Supplement The 1/10Gb Uplink Ethernet Switch Module (GbESM) is one of up to four switch modules that can be installed in the IBM BladeCenter chassis. This release supplement provide the latest information regarding BLADEOS 6.7 for the 1/10Gb Uplink ESM (referred to as GbESM throughout this document). This supplement modifies and extends the following BLADEOS 6.5 documentation for use BLADEOS 6.7: BLADEOS 6.5 Application Guide BLADEOS 6.5 Command Reference BLADEOS 6.5 ISCLI Reference BLADEOS 6.5 BBI Quick Guide 1/10Gb Uplink Ethernet Switch Module Installation Guide The publications listed above are available from the IBM support website: Please keep these release notes with your product manuals. BMD00276-A, August
4 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Hardware Support BLADEOS 6.7 software is supported only on the 1/10Gb Uplink Ethernet Switch Module for IBM BladeCenter. The 1/10Gb Uplink ESM (GbESM) shown in Figure 1 is a high performance Layer 2-3 embedded network switch that features tight integration with IBM BladeCenter management modules. Figure 1 1/10Gb Uplink ESM Faceplate 1 SFP+ slots 10Gb Ethernet 2 3 RS-232 console port 4 7 RJ45 ports 1Gb Ethernet 6 9 The GbESM has the following port capacities: Three external 10Gb SFP+ slots Six external 1Gb Ethernet ports (RJ45) One RS-232 serial console port Two 100Mb internal management ports Fourteen 1000Mb Ethernet internal ports 4 BMD00276-A, August 2011
5 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Updating the Switch Software Image The switch software image is the executable code running on the GbESM. A version of the image comes pre-installed on the device. As new versions of the image are released, you can upgrade the software running on your switch. To get the latest version of software supported for your GbESM, go to the following website: To determine the software version currently used on the switch, use the following switch command: >> # /boot/cur The typical upgrade process for the software image consists of the following steps: Load a new software image and boot image onto an FTP or TFTP server on your network. Transfer the new images to your switch. Specify the new software image as the one which will be loaded into switch memory the next time a switch reset occurs. Reset the switch. For instructions on the typical upgrade process using the CLI, ISCLI, or BBI, see Loading New Software to Your Switch on page 7.! Caution Although the typical upgrade process is all that is necessary in most cases, upgrading from (or reverting to) some versions of BLADEOS requires special steps prior to or after the software installation process. Please be sure to follow all applicable instructions in the following sections to ensure that your switch continues to operate as expected after installing new software. BMD00276-A, August
6 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Special Software Update Issues When updating to BLADEOS 6.7, the following special conditions may apply, depending on the version of software currently installed on your switch. These conditions are cumulative: If updating from version 2.0 (for example), follow the recommendations in order, beginning with those for 2.0, and then continue with all that apply, such as for 3.0 and prior, 4.0 and prior, and so on. Updating from BLADEOS 5.x or Prior After updating: The STG port priority value is different compared to release 5.x and prior. In release 5.x and prior, the priority value could be set to any integer from 0 to 255. In release 6.3 and later, the range is still 0 to 255, but must be specified in increments of 4 (such as 0, 4, 8, 12, and so on). If the specified value is not evenly divisible by 4, the value will be automatically rounded down to the nearest valid increment whenever manually changing the priority value, when loading a configuration from prior to release 6.3, and during the software upgrade process. If using STG port priorities, after upgrading to release 6.3 or later, it is recommended that the administrator review the configured values and make any appropriate changes. (ID: 38556) Updating from BLADEOS 6.1 or Prior! Caution If currently using BLADEOS 6.1 or prior, do not upgrade directly to BLADEOS 6.7. To do so could cause the upgrade to fail. If the switch does not boot after an upgrade attempt, see Recovering from a Failed Upgrade on page 22. The BLADEOS 6.7 software image is not compatible with earlier BLADEOS 6.1 image storage buffers. When updating from BLADEOS 6.1 or prior, first install and boot BLADEOS 6.3 (instead of BLADEOS 6.7). Booting with BLADEOS 6.3 will prepare switch for the expanded BLADEOS 6.7 image file. The switch can then be upgraded to BLADEOS 6.7 using the regular update procedures. After updating: Some time zones are different compared to release and prior. After upgrading to release 6.3 or later, it is recommended that the administrator review the configured time zone and make any appropriate changes. (ID: 29778) Updating from BLADEOS or Prior After updating: The default value for port flow control for external uplink ports is different compared to release or prior. After upgrading to release or later, it is recommended that the administrator review the configured flow control settings and make any appropriate changes. (ID: 43781) 6 BMD00276-A, August 2011
7 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Updating from BLADEOS 6.6 or Prior After updating: The default mode for Spanning Tree is different compared to prior releases. The default mode is now PVRST. After upgrading, it is recommended that the administrator review the STP settings and make any appropriate changes. Loading New Software to Your Switch The GbESM can store up to two different switch software images (called image1 and image2) as well as special boot software (called boot). When you load new software, you must specify where it should be placed: either into image1, image2, or boot. For example, if your active image is currently loaded into image1, you would probably load the new image software into image2. This lets you test the new software and reload the original active image (stored in image1), if needed.! Caution When you upgrade the switch software image, always load the new boot image and the new software image before you reset the switch. If you do not load a new boot image, your switch might not boot properly (To recover, see Recovering from a Failed Upgrade on page 22). To load a new software image to your switch, you will need the following: The image and boot software loaded on an FTP or TFTP server on your network. Note: Be sure to download both the new boot file and the new image file. The hostname or IP address of the FTP or TFTP server Note: The DNS parameters must be configured if specifying hostnames. The name of the new software image or boot file When the software requirements are met, use one of the following procedures to download the new software to your switch. You can use the BLADEOS CLI, the ISCLI, or the BBI to download and activate new software. BMD00276-A, August
8 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Loading Software via the BLADEOS CLI 1. Enter the following Boot Options command: >> # /boot/gtimg 2. Enter the name of the switch software to be replaced: Enter name of switch software image to be replaced ["image1"/"image2"/"boot"]: <image> 3. Enter the hostname or IP address of the FTP or TFTP server. Enter hostname or IP address of FTP/TFTP server: <hostname or IP address> 4. Enter the name of the new software file on the server. Enter name of file on FTP/TFTP server: <filename> The exact form of the name will vary by server. However, the file location is normally relative to the FTP or TFTP directory (usually /tftpboot). 5. Enter your username for the server, if applicable. Enter username for FTP server or hit return for TFTP server: {<username> <Enter>} If entering an FTP server username, you will also be prompted for the password. The system then prompts you to confirm your request. Once confirmed, the software will load into the switch. 6. If software is loaded into a different image than the one most recently booted, the system will prompt you whether you wish to run the new image at next boot. Otherwise, you can enter the following command at the Boot Options# prompt: Boot Options# image The system then informs you of which software image (image1 or image2) is currently set to be loaded at the next reset, and prompts you to enter a new choice: Currently set to use switch software "image1" on next reset. Specify new image to use on next reset ["image1"/"image2"]: Specify the image that contains the newly loaded software. 7. Reboot the switch to run the new software: Boot Options# reset The system prompts you to confirm your request. Once confirmed, the switch will reboot to use the new software. 8 BMD00276-A, August 2011
9 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Loading Software via the ISCLI 1. In Privileged EXEC mode, enter the following command: Router# copy {tftp ftp} {image1 image2 boot-image} 2. Enter the hostname or IP address of the FTP or TFTP server. Address or name of remote host: <name or IP address> 3. Enter the name of the new software file on the server. Source file name: <filename> The exact form of the name will vary by server. However, the file location is normally relative to the FTP or TFTP directory (for example, tftpboot). 4. If required by the FTP or TFTP server, enter the appropriate username and password. 5. The switch will prompt you to confirm your request. Once confirmed, the software will begin loading into the switch. 6. When loading is complete, use the following commands to enter Global Configuration mode to select which software image (image1 or image2) you want to run in switch memory for the next reboot: Router# configure terminal Router(config)# boot image {image1 image2} The system will then verify which image is set to be loaded at the next reset: Next boot will use switch software image1 instead of image2. 7. Reboot the switch to run the new software: Router(config)# reload The system prompts you to confirm your request. Once confirmed, the switch will reboot to use the new software. BMD00276-A, August
10 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Loading Software via BBI You can use the Browser-Based Interface to load software onto the GbESM. The software image to load can reside in one of the following locations: FTP server TFTP server Local computer After you log onto the BBI, perform the following steps to load a software image: 1. Click the Configure context tab in the toolbar. 2. In the Navigation Window, select System > Config/Image Control. The Switch Image and Configuration Management page appears. 3. If you are loading software from your computer (HTTP client), skip this step and go to the next. Otherwise, if you are loading software from a FTP/TFTP server, enter the server s information in the FTP/TFTP Settings section. 4. In the Image Settings section, select the image version you want to replace (Image for Transfer). If you are loading software from a FTP/TFTP server, enter the file name and click Get Image. If you are loading software from your computer, click Browse. In the File Upload Dialog, select the file and click OK. Then click Download via Browser. Once the image has loaded, the page refreshes to show the new software. 10 BMD00276-A, August 2011
11 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement New and Updated Features BLADEOS 6.7 for 1/10Gb Uplink Ethernet Switch Module (GbESM) has been updated to a Virtual Link Aggregation Groups (VLAGs) and other features. The list of features below summarizes the updated features. For more detailed information about configuring GbESM features and capabilities, refer to the complete BLADEOS 6.7 documentation as listed on page 3.! Caution Do not upgrade directly to BLADEOS 6.7 if currently using BLADEOS 6.1 or prior. See Updating from BLADEOS 6.1 or Prior on page 6 for appropriate upgrade procedures. Advanced Buffer Optimization In BLADEOS 6.7, the 1/10Gb Uplink ESM allows advanced administrators to optimize port ingress and egress buffers for their particular network application. Buffer configuration is available using the following menu: > # /cfg/qos/advbuf! Caution Changing the port buffer settings can significantly alter switch performance. Improper settings can degrade or disrupt traffic. The default buffer values are broadly recommended for most applications. Before changing any buffer values, the administrator should be familiar with switch and network performance characteristics and able to perform a rigorous network evaluation to verify expected operation. To reset individual parameters to the recommended internal default values, specify 0 as the value. For example: > # /cfg/qos/advbuf/egress/totcell 0 0 To reset all ingress buffer parameters, use the following command: > # /cfg/qos/advbuf/ingress/default BMD00276-A, August
12 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Command Interface Enhancements ISCLI Update The ISCLI has been enhanced to be more consistent with common standards. The following command equivalents have been added: Table 1 New ISCLI Commands New Command write memory wr show logging show interface status show interface counters Function/Legacy Equivalent Saves the configuration and sets it as active automatically (without prompting).similar to: copy running startup Equivalent to: show logging messages Equivalent to show interface link Equivalent to: show int port 1-<X> interface-counters Where X is the highest available port. show ip interface brief Equivalent to: show ip info show interface trunk Equivalent to: show int info show interface transceiver Equivalent to: show transceiver show processes cpu Equivalent to: show mp cpu show user Equivalent to: show who show arp Equivalent to: show ip arp show etherchannel summary Displays output equivalent to two commands: show portchannel information show lacp information clear counters Equivalent to: clear interfaces clear arp Equivalent to: clear ip arp-cache 12 BMD00276-A, August 2011
13 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Output Filtering Some commands designed to display configuration settings or other switch information can potentially generate lengthy output. For circumstances where only a specific portion of the output is of interest to the administrator, the switch now provides command filters for limiting switch output. Applicable Commands Output filters can be applied to the following types of commands: In the menu-based CLI: All commands under the Information menu (/info) and its sub-menus All cur commands In the Industry-Standard CLI (ISCLI), all show commands Filter Types The following types of filters are available: Include Lines Display only the lines that include a specified regular expression. Format: <command> include <RegEx> For example, to display the line that includes the string MAC (containing the switch s MAC address and primary IP interface address): >> # /info/sys/general include MAC Exclude Lines Display all lines except those that include a specified regular expression. Format: <command> exclude <RegEx> Set Beginning Display the output beginning from the line that includes a specified regular expression. Format: <command> begin <RegEx> Set Section For output that includes different sections, display only the section of the output that includes a specified regular expression. Format: <command> section <RegEx> For output that does not have sections, this filter will act the same as the begin filter. Note Lines with output greater than 300 characters long will be split into multiple lines, with each fragment filtered individually. Also, because the question mark (? ) is used to display command help, the question mark cannot be used within the expression specified in the filter. BMD00276-A, August
14 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Global Flooding Options Options for configuring flooding are no longer available under the IGMP menus. Instead, flooding commands have been moved to the VLAN Flooding menu (/cfg/l3/flooding/vlan) and are available regardless of the IGMP state. Any existing flooding configuration is preserved and automatically converted to the new command location when upgrading to BLADEOS 6.7 or higher. When loading configuration files from versions prior to BLADEOS 6.7, any flooding configuration in the files are automatically converted. In addition, a new option in the VLAN Flooding menu for optimized flooding (optflood) has been added. When enabled, optimized flooding avoids packet loss during the learning period. This option is disabled by default. IPv6 Enhancements for NIST USGv6 To support the National Institute of Standards and Technology (NIST) recommendations for IPv6 implementations, BLADEOS 6.7 IPv6 feature compliance has been extended to include the following IETF RFCs, with an emphasis on IP Security (IPsec) and Internet Key Exchange version 2, Multicast Listener Discovery (MLD) versions 1 and 2, and authentication/confidentiality for OSPFv3: RFC 2740 for OSPF RFCs 3306 and 3307 for dynamic IPv6 multicast addresses RFC 3810 for MLDv2 RFC 4301 for IPv6 security RFC 4302 for the IPv6 Authentication Header RFCs 2404, 2410, 2451, 3602, and 4303 for IPv6 Encapsulating Security Payload (ESP), including NULL encryption, CBC-mode 3DES and AES ciphers, and HMAC-SHA RFCs 4306, 4307, 4718, and 4835 for IKEv2 and cryptography RFC 4552 for OSPFv3 IPv6 authentication RFC 5114 for Diffie-Hellman groups 14 BMD00276-A, August 2011
15 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement IPsec/IKE for IPv6 Internet Protocol Security (IPsec) is a protocol suite for securing Internet Protocol (IP) communications by authenticating and encrypting each IP packet of a communication session. IPsec also includes protocols for establishing mutual authentication between agents at the beginning of the session and for the negotiation of cryptographic keys to be used during the session. The BLADEOS implementation of IPsec supports the following protocols: Authentication Header (AH) AHs provide connectionless integrity and data origin authentication for IP packets, and provide protection against replay attacks. In IPv6, the AH protects the AH itself, the Destination Options extension header after the AH, and the IP payload. It also protects the fixed IPv6 header and all extension headers before the AH, except for the mutable fields DSCP, ECN, Flow Label, and Hop Limit. AH is defined in RFC Encapsulating Security Payload (ESP) ESPs provide confidentiality, data origin authentication, connectionless integrity, an anti-replay service (a form of partial sequence integrity), and some traffic flow confidentiality. ESPs may be applied alone or in combination with an AH. ESP is defined in RFC Internet Key Exchange (IKE) IKE is used for mutual authentication between two network elements. An IKE establishes a security association (SA) that includes shared secret information to efficiently establish SAs for ESPs and AHs, and a set of cryptographic algorithms to be used by the SAs to protect the associated traffic. IKE is defined in RFCs 4109 (IKEv1) and 4306 (IKEv2). Using IKE as the foundation, IPsec supports ESP for encryption and/or authentication, and/or AH for authentication of the remote partner. To configure IPsec, you must define a key policy. The following is needed to configure a manual key policy: The IP address of the peer This may be in either IPv4 or IPv6 format. The traffic selector This describes the packets to which the policy applies. The transform set This defines which encryption and authentication algorithms are used. Inbound/Outbound session keys for the security protocols. You can then assign the policy to an interface. The peer represents the other end of the security association. The security protocol for the session key is either ESP or AH. Outgoing packets are labeled with the SA SPI (Security Parameter Index), which the remote device will use in its verification and decryption process. The commands for configuring and administering IPsec are located under the following menus: >> # /cfg/l3/ipsec >> # /cfg/l3/ikev2 BMD00276-A, August
16 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Loopback Interfaces A loopback interface provides an IP address, but is not otherwise associated with a physical port or network entity. Essentially, it is a virtual interface that is perceived as being always available for higher-layer protocols to use and advertise to the network, regardless of other connectivity. Loopback interfaces improve switch access, increase reliability, security, and provide greater flexibility in Layer 3 network designs. They can be used for many different purposes, but are most commonly for management IP addresses, router IDs for various protocols, and persistent peer IDs for neighbor relationships. In BLADEOS 6.7, loopback interfaces have been expanded for use with routing protocols such as OSPF and BGP. Loopback interfaces can also be specified as the source IP address for syslog, SNMP, RADIUS, TACACS+, NTP, and router IDs. Loopback interfaces must be configured before they can be used in other features. Up to 5 loopback interfaces are currently supported. They can be configured using the following commands: GbESM(config)# interface loopback <1-5> GbESM(config-ip-loopback)# [no] ip address <IPv4 address> <mask> enable GbESM(config-ip-loopback)# exit Loopback Interfaces in OSPF Because loopback interfaces are always available on the switch, loopback interfaces may present an advantage when used as the router ID. If dynamic router ID selection is used, loopback interfaces can be used to force router ID selection. If a loopback interface is configured, its IP address is automatically selected as the router ID, even if other IP interfaces have lower IP addresses. If more than one loopback interface is configured, the lowest loopback interface IP address is selected. Loopback interfaces can be advertised into the OSPF domain by specifying an OSPF host route with the loopback interface IP address. Note Loopback interfaces are not advertised via the OSPF route redistribution of fixed routes. To enable OSPF on an existing loopback interface: GbESM(config)# interface loopback <1-5> GbESM(config-ip-loopback)# ip ospf area <area ID> enable GbESM(config-ip-loopback)# exit 16 BMD00276-A, August 2011
17 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Loopback Interfaces in BGP In many networks, multiple connections may exist between network devices. In such environments, it may be useful to employ a loopback interface for a common BGP router address, rather than peering the switch to each individual interface. When a loopback interface is created for BGP, the switch automatically uses the loopback interface as the BGP peer ID, instead of the switch s local IP interface address. Note To ensure that the loopback interface is reachable from peer devices, it should be advertised using an interior routing protocol (such as OSPF), or a static route should be configured on the peer. To configure an existing loopback interface for BGP neighbor use: GbESM(config)# router bgp GbESM(config-router-bgp)# neighbor <#> update-source loopback <1-5> GbESM(config-router-bgp)# exit Using Loopback Interfaces for Source IP Addresses The switch can use loopback interfaces to set the source IP addresses for a variety of protocols. This assists in server security, as the server for each protocol can be configured to accept protocol packets only from the expected loopback address block. It may also make is easier to locate or process protocol information, since packets have the source IP address of the loopback interface, rather than numerous egress interfaces. Configured loopback interfaces can be applied to the following protocols: Syslogs GbESM(config)# logging source-interface loopback <1-5> SNMP traps GbESM(config)# snmp-server trap-source loopback <1-5> RADIUS GbESM(config)# ip radius source-interface loopback <1-5> TACACS+ GbESM(config)# ip tacacs source-interface loopback <1-5> NTP GbESM(config)# ntp source loopback <1-5> BMD00276-A, August
18 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Loopback Interface Limitation ARP is not supported. Loopback interfaces will ignore ARP requests. Loopback interfaces cannot be assigned to a VLAN. MLD for IPv6 Multicast Listener Discovery (MLD) is an IPv6 protocol that a host uses to request multicast data for a particular group. Using the information obtained through MLD, the software maintains a list of multicast group or channel memberships on a per-interface basis. MLD is defined in RFC 2710 (MLDv1) and RFC 3810 (MLDv2). Customers that use IPv6 messages to subscribe to group memberships use MLD so each multicast router can learn, for each of its directly attached links, which multicast addresses and which sources have interested listeners on its links. The information gathered by MLD is provided to whichever multicast routing protocol is used by the router to ensure that multicast packets are delivered to all links where there are listeners interested in such packets. STP with Automatic STG Assignment The Spanning Tree feature has been enhanced to simplify switch configuration. To begin, PVRST is now the default Spanning-Tree mode. The previous default was STP/PVST+ mode (see the BLADEOS 6.5 Application Guide for details on Spanning Tree Protocols). In addition, VLAN Automatic STG Assignment (VASA) is now available in PVRST mode. With VASA enabled, it is no longer necessary to manually assign Spanning-Tree Groups (STGs) for each VLAN. Instead, STG assignment is automated. Each time a new VLAN is configured, the switch will automatically assign the new VLAN its own STG. Conversely, when a VLAN is deleted, if its STG is not associated with any other VLAN, the STG is returned to the available pool. If an empty STG is not available when creating a new VLAN, the default STG (STG 1) is automatically assigned. VASA is enabled by default, but can be disabled or re-enabled using the following commands: >> # /cfg/l2/vlanstg e d VASA applies only to PVRST mode and is ignored in RSTP and MSTP modes. When VASA is enabled, manual STG assignment is still available. The administrator may assign a specific STG to a VLAN using regular commands: >> # /cfg/l2/stg <STG number>/add <VLAN number> 18 BMD00276-A, August 2011
19 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Trunking LACP Minimum Links For dynamic trunks that require a guaranteed amount of bandwidth in order to be considered useful, it is now possible to specify the minimum number of links for the trunk. If the specified minimum number of ports are not available, the trunk link will not be established. If an active LACP trunk loses one or more component links, the trunk will be placed in the down state if the number of links falls below the specified minimum. By default, the minimum number of links is 1, meaning that LACP trunks will remain operational as long as at least one link is available. The LACP minimum links setting can be configured as follows: > # /cfg/l2/lacp/port <port number or range>/minlinks <minimum links> LAG Group Statistics Statistics are now available for trunk group ports using the following command: >> # /stats/trunk <trunk ID>/if For static trunks, port statistics are collected for all enabled ports in the trunk group. For dynamic, LACP trunks, port statistics are collected for all active ports in the trunk group. Other Features and Enhancements VMready Support for VMware ESX 4.1. Digital optical monitoring (DOM) signal strength levels (TXuW and RXuW) are now shown in the output of the show transceiver command. BMD00276-A, August
20 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Resolved Issues Fixed a condition where, some of the IGMP configuration parameters were reset after stack master failback when the switch is in stacking mode. (ID 48515) Fixed a condition in OSPFv3 where ECMP routes were removed when a port was removed from a trunk. (ID 50221) The administrator is no allowed to change the configuration of the Spanning-Tree Group (STG) 128, which is reserved for switch management traffic. (ID 50435) Fixed a condition where the switch was unexpectedly reset when trying to upgrade the boot kernel image using SCP. (ID 51080) 20 BMD00276-A, August 2011
21 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Supplemental Information This section provides additional information about configuring and operating the GbESM and BLADEOS. The Boot Management Menu The Boot Management menu allows you to switch the software image, reset the switch to factory defaults, or to recover from a failed software download. You can interrupt the boot process and enter the Boot Management menu from the serial console port. When the system displays Memory Test, press <Shift B>. The Boot Management menu appears. Resetting the System... Memory Test... Boot Management Menu 1 - Change booting image 2 - Change configuration block 3 - Xmodem download 4 - Exit Please choose your menu option: 1 Current boot image is 1. Enter image to boot: 1 or 2: 2 Booting from image 2 The Boot Management menu allows you to perform the following actions: To change the booting image, press 1 and follow the screen prompts. To change the configuration block, press 2, and follow the screen prompts. To perform an Xmodem download, press 3 and follow the screen prompts. To exit the Boot Management menu, press 4. The booting process continues. BMD00276-A, August
22 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Recovering from a Failed Upgrade Use the following procedure to recover from a failed software upgrade. 1. Connect a PC to the serial port of the switch. 2. Open a terminal emulator program that supports XModem Download (for example, HyperTerminal, CRT, PuTTY) and select the following serial port characteristics: Speed: 9600 bps Data Bits: 8 Stop Bits: 1 Parity: None Flow Control: None 3. Boot the switch and access the Boot Management menu by pressing <Shift B> while the Memory Test is in progress and the dots are being displayed. 4. Select 3 for Xmodem download. When you see the following message, change the Serial Port characteristics to bps: ## Switch baudrate to bps and press ENTER Press <Enter> to set the system into download accept mode. When the readiness meter displays (a series of C characters), start XModem on your terminal emulator. 22 BMD00276-A, August 2011
23 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement 6. Select the Boot Image to download. The XModem initiates the file transfer. When the download is complete, a message similar to the following is displayed: yzmodem - CRC mode, 62494(SOH)/0(STX)/0(CAN) packets, 6 retries Extracting images... Do *NOT* power cycle the switch. **** VMLINUX **** Un-Protected 10 sectors Erasing Flash... done Writing to Flash...done Protected 10 sectors **** RAMDISK **** Un-Protected 44 sectors Erasing Flash... done Writing to Flash...done Protected 44 sectors **** BOOT CODE **** Un-Protected 8 sectors Erasing Flash... done Writing to Flash...done Protected 8 sectors 7. When you see the following message, change the Serial Port characteristics to 9600 bps: ## Switch baudrate to 9600 bps and press ESC Press the Escape key (<Esc>) to re-display the Boot Management menu. 9. Select 3 to start a new XModem Download. When you see the following message, change the Serial Port characteristics to bps: ## Switch baudrate to bps and press ENTER... BMD00276-A, August
24 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM 10. Press <Enter> to continue the download. 11. Select the OS Image to download. The XModem initiates the file transfer. When the download is complete, a message similar to the following is displayed: yzmodem - CRC mode, 27186(SOH)/0(STX)/0(CAN) packets, 6 retries Extracting images... Do *NOT* power cycle the switch. **** Switch OS **** Please choose the Switch OS Image to upgrade [1 2 n] : 12. Select the image number to load the new image (1 or 2). It is recommended that you select 1. A message similar to the following is displayed: Switch OS Image 1... Un-Protected 27 sectors Erasing Flash... done Writing to Flash...done Protected 27 sectors 13. When you see the following message, change the Serial Port characteristics to 9600 bps: ## Switch baudrate to 9600 bps and press ESC Press the Escape key (<Esc>) to re-display the Boot Management menu. 15. Select 4 to exit and boot the new image. 24 BMD00276-A, August 2011
25 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Management Module The Fast POST=Disabled/Enabled inside the IBM management module Web interface I/O Module Admin Power/Restart does not apply to the GbESM. Solution: To boot with Fast or Extended POST, go to the I/O Module Admin/Power/Restart window. Select the GbESM, and then choose Restart Module and Run Standard Diagnostics or Restart Module and Run Extended Diagnostics. The following table correlates the Firmware Type listed in the IBM management module s Web interface Firmware VPD window to the GbESM software version: Table 2 Firmware Type list Firmware Type Boot ROM Main Application 1 Main Application 2 Description GbESM Boot code version Currently running image Backup image Within the IBM management module Web interface, the Java applets of Start Telnet Session and Start Web Session do not support changing of default known ports 23 and 80 respectively. Solution: If the Telnet or HTTP port on the GbESM is changed to something other than the default port number, the user must use a separate Telnet client or Web browser that supports specifying a non-default port to start a session to the GbESM user interface. Management Module/GbESM Connectivity Currently, the IBM management module is designed to provide one-way control of the GbESM. As a result, the GbESM may lose connectivity to the management module via the management port under the following conditions: If new IP attributes are pushed from the management module to the GbESM while the IP Routing table is full, the new attributes will not be applied. Solution: Enable External Management over all ports, connect to the switch using other interface and then clear the routing table. Then push the IP address from the management module. If this does not work, use Solution 2 below. If you execute the /boot/reset CLI command on the GbESM or the GbESM resets itself, the management module might not push the IP attributes to the switch, and connectivity may be lost. BMD00276-A, August
26 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Solution 1: If you should experience any connectivity issues between the switch module and the management module, go to the I/O Module Configuration window on the management module s Web interface. Under the New Static IP Configuration section, click Save to trigger the management module to push the stored IP attributes to the switch module. Solution 2: If Solution 1 does not resolve your connectivity issue, then go to the I/O Module Admin/Power/Restart window on the management module s Web interface. Restart the switch module in question. Solution 3: If this still does not resolve the issue, enable Preserve new IP configuration on all resets setting on the management module and restart the switch module via the I/O Module Admin/Power/Restart window on the management module s Web interface. Note As a rule, always use the management module Web interface to change the GbESM management IP attributes (IP address, mask and gateway), and then click Save to push the IP attributes to the switch module. Use of the command-line interface to change the switch module management IP attributes may result in duplicated entries for the management IP Interface in the switch route table and/or loss of connectivity via the management module. Internal Port Autonegotiation By default, link autonegotiation is turned on for internal ports. This is in contrast to external ports, where autonegotiation is off by default. Internal ports use autonegotiation in order to support the Wake-Over-LAN (WOL) features of some servers. If an attached server does not support autonegotiation or WOL, turn autonegotiation off for the internal port. FTP/TFTP Directory Path When you use the CLI to perform a FTP/TFTP file transfer, you cannot use a forward slash ( / ) in the directory path, unless it is preceded by a back slash ( \ ). This issue occurs only when a full command is issued on one line. For example, the following is invalid: # /boot/gtimg image_directory/filename The following is correct: # /boot/gtimg image_directory\/filename 26 BMD00276-A, August 2011
27 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Secure Management Network The following GbESM attributes are reserved to provide secure management access to and from the IBM management module: MGT1 (port 15) and MGT2 (port 16) VLAN 4095 IP interface 128 Gateway 4 STG 128 For more information about remotely managing the GbESM through the external ports, see Accessing the Switch in the BLADEOS 6.7 Application Guide. Note The external uplink ports (EXTx) cannot be members of management VLANs. Secure Shell (SSH) Because SSH key generation is CPU intensive, the GbESM attempts to avoid unnecessary key generation. The process generates three server keys: 1. One key is generated to replace the current server key, if used. 2. A second key is generated as a spare, in case the current server key is used and the specified interval expires. 3. A third key is generated for use at the next reboot. Therefore, if you never login via SSH, you will only see two key generation events. You may see all three events directly following a reboot. If you want to witness the key generation after the specified interval has expired, then you must login via SSH at least once during each expiration interval. Spanning Tree Configuration Tips To ensure proper operation with switches that use Cisco Per VLAN Spanning Tree (PVST+), you must do one of the following: Create a separate Spanning Tree Group for each VLAN. Manually add all associated VLANs into a single Spanning Tree Group. When using Layer 2 Trunk Failover, disable Spanning Tree Protocol on external ports. BMD00276-A, August
28 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Syslog Configuration Tip The facility parameter traditionally is used to correlate services (such as IP, CLI, etc.) to messages. This is done to distinguish between the different services that are running in the network/device. However, for the GbESM, there is a single configured facility value (0-7) used on all messages. By configuring a unique facility value for each switch, a single SYSLOG server can distinguish between the various GbESMs in the network. Refer to System Host Log Configuration in the Command Reference. Trunk Group Configuration Tips Please be aware of the following information when you configure trunk groups: Always configure trunk groups first, on both ends, before you physically connect the links. Configure all ports in a trunk group to the same speed (you cannot aggregate 1Gb ports with 10GBASE-SFP+ ports). vcenter Synchronization When applying distributed VM group configuration changes, the switch will attempt to synchronize settings with the VMware vcenter for virtualization management. If the vcenter is unavailable, an error message will be displayed on the switch. Be sure to evaluate all error message and take the appropriate actions to ensure the expected changes are properly applied. If corrective actions are not taken, synchronization may remain incomplete when connection with the vcenter is restored. Solution: When the switch connection with the vcenter is restored, use the following operational command to force synchronization: >> # /oper/virt/vmware/scan 28 BMD00276-A, August 2011
29 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement Known Issues This section describes known issues for BLADEOS 6.7 on the 1/10Gb Uplink Ethernet Switch Module. ACLs When an Access Control List (ACL) is installed on two different ports, only one statistics counter will be available. The GbESM does not support two different statistics counter for one ACL installed on two different ports. The ACL filters for TCP/UDP work properly only on packets that do not have IP options. When you assign an ACL (or ACL Group) to one port in a trunk, BLADEOS does not automatically assign the ACL to other ports in the trunk, and it does not prompt you to assign the ACL to other ports in the trunk. Manually assign each ACL or ACL Group to all ports in the trunk. When configuring an ACL to set 802.1p priority for in-profile packets, and updating the DSCP field using TOS bits for out-of-profile packets, the out-of-profile packets will have also the 802.1p priority set as defined in the in-profile setting. Although the management port can be configured for port filtering option, actual port filtering will not occur, because the system filters out the management VLAN. AMP For proper AMP operation, all access switches should be configured with a higher priority value (lower precedence) than the aggregators. Otherwise, unexpected AMP keep-alive packets may be forwarded from one aggregator switch to the other, even when its AMP group is disabled. (ID: 37310) BBI Some versions of Microsoft Internet Explorer version 6.x do not perform HTTP download efficiently. If you have one of these versions, HTTP software download might take much longer than expected (up to several minutes). Web-browsers from different vendors may vary in their support of standard features. If you encounter problems using the BBI in a particular browser, a different browser may resolve the issue. BMD00276-A, August
30 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Boot Configuration Block In the CLI, the boot configuration command (/boot/conf <block>) examines only the initial character of the block option. Invalid block strings (those other than active, backup, or factory) that use a valid first character (a, b, or f) will be interpreted as the matching valid string. (ID: 42422) Daylight Saving Time For the Asia/Israel time zone, BLADEOS sets the end of Daylight Saving Time (DST) as the last week in September. However, because the observed end of DST varies according to the date of the Yom Kippur holiday in the Hebrew calendar since 2005, occurring on various Saturdays in September or October, the default DST rule may not work as desired. For the Asia/Israel time zone, or any other time zone in which the start or end date of DST varies from year to year, the administrator should create a custom DST rule for those years in which DST is desired, but ends in a different week than the set by default. Hotlinks Prior to enabling hotlinks, Spanning-Tree should be globally disabled using the following command (ID: 47917): GbESM(config)# spanning-tree mode dis IGMP In IGMP relay, when having joins from multiple VLANs, and the multicast data transmitter is on a VLAN that did not receive any joins, multicast data is routed only if the flood option is disabled using the /cfg/l3/igmp/adv/flood d command. In IGMP relay, if an IGMP v2 joins an IGMP group on the same port where an IGMP v1 join has already been issued, the software will default to the IGMP v1 timeout value. If a port has a static multicast router (Mrouter) configured, and you move the port to a different VLAN, the static Mrouter appears in the /info/l3/igmp/mrouter/dump output for the original VLAN. When you move the port to a new VLAN, remove the static Mrouter from the port, and add it again. IP Gateways Although the switch allows IPv4 gateways numbered 1 through 132 to be configured, the 1/10Gb Uplink ESM supports only IPv4 gateways numbered 1 to 4. IPv4 gateways 5 through 132 are not supported and should not be configured. (ID: 42433) 30 BMD00276-A, August 2011
31 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement LACP If a static trunk on a GbESM is connected to another GbESM with LACP configured (but no active LACP trunk), the /info/l2/trunk command might erroneously report the static trunk as forwarding. Since LACP trunks use LACPDU packet to maintain trunking with the partner, there is a possibility for those packets to be dropped from an extremely busy trunk. If this happens, some links in the LACP trunk might be removed, then aggregated back to the trunk if an LACPDU is received. To avoid this unstable LACP trunk link, you can add more links to the trunk to increase the bandwidth, or use regular static trunk if there are no more links available. OSPF Some changes to OSPF configuration (such as creating a new area or changing an area s type) may result in OSPF state reconvergence. (ID: 46445, 48483) OSPFv3 over IPsec This combination can only be configured only on a per-interface basis. Configuration based on virtual links is not currently supported. The current implementation for OSPFv3 allows the use of only one protocol (AH or ESP) at any given time. AH and ESP cannot be applied together. Password Expiration If you configure a Strong Password with automatic expiration, the password might not expire if the system date and time is not configured first. Use of a Network Time Protocol (NTP) server resolves this issue. Solution: When you configure a strong password with automatic expiration, first configure the system time and date for the switch. BMD00276-A, August
32 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM Ports and Transceivers When the link speed for an external connection is forced (i.e. no Auto-Negotiation) to 100 Mbps and then changed to 10 Mbps, if the external device is changed first, the external device may erroneously report the link as DOWN even after the GbESM is changed to 10 Mbps. Solution: At the external device, disconnect and reconnect the cable. Interoperability with Older Hubs The command-line interface might display link up and link down messages continuously for an external port that is connected to certain older hub models configured for 100 Mbps half-duplex. The display might show link up erroneously. This behavior has been observed when connecting the GbESM with the following devices: NETGEAR FE hub SBS 1000Base-T NIC 3Com Linkbuilder FMS100 Hub 3C250 TX/I 3Com SuperStack II 100TX 3C250C-TX-24/12 Nortel Baystack 204 Hub If the GbESM is connected to an application switch which requires a link speed of 100 Mbps half-duplex, then enable auto negotiation on the GbESM port with port speed=any, mode=any, fctl=both, and auto=on. QoS Metering Traffic may exceed the configured maximum burst size of the ACL meter (/cfg/port <x>/aclqos/meter/mbsize) by one packet, with that packet remaining In-Profile. Once the ACL meter has been exceeded, additional burst packets fall Out-of-Profile. RADIUS with SSHv2 With RADIUS turned on, users might see a duplicate login prompt for SSHv2 clients if the RADIUS server is too slow to respond or if the RADIUS server is not available. In this case, users must re-type the username and password to login. 32 BMD00276-A, August 2011
33 1/10Gb Uplink ESM BLADEOS 6.7 Release Supplement SNMP Due to backward-compatibility issues, two Routing Information Protocol (RIP) MIBs are available in BLADEOS: ripcfg and rip2cfg. Use the rip2cfg MIB to configure RIPv1 and RIPv2 through SNMP. BLADEOS does not support the standard RIPv2 MIB as described in RFC Use the rip2cfg MIB to configure RIPv1 and RIPv2 through SNMP. Statistics The counter for empty egress port map discards may increase on ports used for stacking. This is the because all multicast or broadcast traffic gets flooded to all stacking ports. Discard of these packets is normal and expected on the stacking ports. Trunking Multicast, broadcast and DLF (Destination Lookup Failure, which are unknown destination MAC packets) traffic is sent to the lowest numbered port in the trunk. If this port is down, then the traffic is sent to the next lowest-numbered port. If the port that was down comes up again, the traffic is not re-hashed back to the recovered port. Tx Ring Loop When you create a trunk or link loop between the GbESM and another switch, packets might loop infinitely at line rate within the related links. When this problem occurs, the GbESM continuously displays the following messages at the console: WARNING: packet_sent u: 0, dv_active: tx ring full packet_sent dcnt=114, public1=110, vcnt=1025 Remove the loop to resolve this misconfiguration. VMready The GbESM does not support IPv6 on VMs. If a VM attached to the switch is using IPv6 addressing, the output of VM-related information commands (such as /info/virt/vm/vmware/showvm <IPv6 address>) will be incorrect. (ID: 42876) VMs belonging to different ESX servers cannot ping each other across different VM groups. Because the VM groups belong to different VLANs, this is appropriate and expected behavior. BMD00276-A, August
34 BLADEOS 6.7 Release Supplement 1/10Gb Uplink ESM 34 BMD00276-A, August 2011
Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Version 1.0
Alteon OS Release Notes Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter Version 1.0 Part Number: 31R1724, June 2006 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net
IBM Networking OS. Release Notes. for the IBM Flex System EN2092 1Gb Ethernet Scalable Switch
IBM Networking OS Release Notes for the IBM Flex System EN2092 1Gb Ethernet Scalable Switch Note: Before using this information and the product it supports, read the general information in the Safety information
BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1
BLADE OS BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Part Number: BMD00116, August 2009 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net Copyright 2009
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration Utility 1 Launching the Configuration
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
Release Notes TM. BLADEHarmony Manager Version 3.2. Part Number: BMD00093, July 2009
Release Notes TM BLADEHarmony Manager Version 3.2 Part Number: BMD00093, July 2009 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net Copyright 2009 Blade Network Technologies,
AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
SonicOS Enhanced 5.7.0.2 Release Notes
SonicOS Contents Platform Compatibility... 1 Key Features... 2 Known Issues... 3 Resolved Issues... 4 Upgrading SonicOS Enhanced Image Procedures... 6 Related Technical Documentation... 11 Platform Compatibility
AlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes
4 AlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes Please read this document before you begin to use the management software. The document has the following
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
Web Browser Interface User s Guide
Management Software AT-S62 Web Browser Interface User s Guide AT-8516F/SC, AT-8524M, AT-8524POE, AT-8550GB and AT-8550SP LAYER 2+ FAST ETHERNET SWITCHES VERSION 1.3.0 PN 613-000127 Rev A Copyright 2005
Chapter 8 Router and Network Management
Chapter 8 Router and Network Management This chapter describes how to use the network management features of your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. These features can be found by
ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004
ZyWALL 5 Internet Security Appliance Quick Start Guide Version 3.62 (XD.0) May 2004 Introducing the ZyWALL The ZyWALL 5 is the ideal secure gateway for all data passing between the Internet and the LAN.
20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch
GTL-2691 Version: 1 Modules are to be ordered separately. 20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch The LevelOne GEL-2691 is a Layer 3 Managed switch with 24 x 1000Base-T ports associated
LifeSize Video Communications Systems Administrator Guide
LifeSize Video Communications Systems Administrator Guide November 2009 Copyright Notice 2005-2009 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made
Brocade to Cisco Comparisons
1 2 3 Console cables - The console cables are not interchangeable between Brocade and Cisco. Each vendor provides their console cable with each manageable unit it sells. Passwords - Neither Cisco or Brocade
FWS WiTDM Series KWA-O8800-I User Manual
FWS WiTDM Series KWA-O8800-I User Manual Date: 2009 / 04 / 23 Version: 1.0 1 Copyright This user s manual and the software described in it are copyrighted with all rights reserved. No part of this publication
AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes
Supported Platforms AT-S62 and AT-S62 NE Version 1.2.1 Software Release Notes AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes Please read this
Easy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide 10/100 Switches SF 300-08, SF 302-08, SF 302-08MP, SF 302-08P, SF 300-24, SF 300-24P, SF 300-48, SF 300-48P Gigabit
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
Starting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
UIP1868P User Interface Guide
UIP1868P User Interface Guide (Firmware version 0.13.4 and later) V1.1 Monday, July 8, 2005 Table of Contents Opening the UIP1868P's Configuration Utility... 3 Connecting to Your Broadband Modem... 4 Setting
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes Supported Platforms Please read this document before you begin to
Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch
University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 Lab. 2 Network Devices & Packet Tracer Objectives 1. To become familiar with
Port Trunking. Contents
12 Port Trunking Contents Overview..................................................... 12-2................................... 12-2 Port Connections and Configuration.......................... 12-3 Link
Port Trunking. Contents
13 Port Trunking Contents Overview.................................................... 13-2 Port Trunk Features and Operation........................... 13-4 Trunk Configuration Methods................................
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches Software Administration Manual December 2013 202-11137-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation This chapter describes how to configure trunk groups and 802.3ad link aggregation. Trunk groups are manually-configured aggregate links containing
Command Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 1.3.0 613-000789 Rev. A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part
How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29
Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business SFE/SGE Managed Switches 2009 Cisco Systems, Inc. All rights reserved. OL-20139-01 Contents Contents Chapter 1: Getting Started 1 Starting the Application 1 Understanding
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
Command Line User s Guide
Management Software AT-S63 Command Line User s Guide For AT-9400 Switch Stacks AT-S63 Version 3.2.0 for AT-9400 Basic Layer 3 Switches 613-001027 Rev. A Copyright 2008 Allied Telesis, Inc. All rights reserved.
Skills Assessment Student Training Exam
Skills Assessment Student Training Exam Topology Assessment Objectives Part 1: Initialize Devices (8 points, 5 minutes) Part 2: Configure Device Basic Settings (28 points, 30 minutes) Part 3: Configure
ProSafe Managed Switch
ProSafe Managed Switch Web Management User Manual Version 9.0.2 GSM5212P GSM7212F GSM7212P GSM7224P 350 East Plumeria Drive San Jose, CA 95134 USA November, 2011 202-10967-01 v1.0 2011 NETGEAR, Inc. All
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes Please read this document before you begin to use the management software. Supported
File Transfers. Contents
A File Transfers Contents Overview..................................................... A-2................................... A-2 General Switch Software Download Rules..................... A-3 Using
Switch Quick Configuration CLI Guide for
Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 /
VIP-102B IP Solutions Setup Tool Reference Manual
VIP-102B IP Solutions Setup Tool Reference Manual Table of Contents Overview... 5 System Requirements for Managed VoIP Products... 6 Term Definitions... 7 Main Application Window... 8 Legend Description...
Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M
Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M Contents: Software Updates Are Free! New Software Release 05.0.84 Module Installation Getting Started Your Free Ticket to
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported Platforms The following
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches Please read this document before you begin to use the management software. NOTE This
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
Unified Access Point Administrator's Guide
Unified Access Point Administrator's Guide Product Model: DWL-3600AP DWL-6600AP DWL-8600AP Unified Wired & Wireless Access System Release 2.0 November 2011 Copyright 2011. All rights reserved. November
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
VIP-102B IP Solutions Setup Tool Reference Manual
VIP-102B IP Solutions Setup Tool Reference Manual Table of Contents Overview...5 System Requirements for Managed VoIP Products...6 Term Definitions...7 Main Application Window...8 Legend Description...9
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
Using SolarWinds Orion for Cisco Assessments
Using SolarWinds Orion for Cisco Assessments Cisco Network Assessments Registering Your Assessment... 1 Installing SolarWinds Orion Network Performance Monitor... 1 Discovering Your Network... 1 Polling
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch 24-Port Giga PoE Current Sharing Pv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version 2.0 Authentication TACACS+ Jumbo Frames
User Guide XMS-1024P 24 Port Gigabit Managed PoE/PoE+ Switch
Simply Connected User Guide XMS-1024P 24 Port Gigabit Managed PoE/PoE+ Switch Use the XMS-1024P to: Cost-effectively Add 802.3af/at PoE Capability to Your Network Deliver Power and Data for up to 24 PoE-Enabled
Installing and Using the vnios Trial
Installing and Using the vnios Trial The vnios Trial is a software package designed for efficient evaluation of the Infoblox vnios appliance platform. Providing the complete suite of DNS, DHCP and IPAM
Exploring the Remote Access Configuration Utility
Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
LotWan Appliance User Guide USER GUIDE
LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document
USER S GUIDE Switched Rack PDU
Contents Introduction--1 Product Description....................................... 1 Access Procedures....................................... 3 Recover From a Lost Password..............................
"Charting the Course...
Description "Charting the Course... Course Summary Interconnecting Cisco Networking Devices: Accelerated (CCNAX), is a course consisting of ICND1 and ICND2 content in its entirety, but with the content
Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)
Cisco Certified Network Associate Exam Exam Number 200-120 CCNA Associated Certifications CCNA Routing and Switching Operation of IP Data Networks Operation of IP Data Networks Recognize the purpose and
HP Load Balancing Module
HP Load Balancing Module Load Balancing Configuration Guide Part number: 5998-2685 Document version: 6PW101-20120217 Legal and notice information Copyright 2012 Hewlett-Packard Development Company, L.P.
FortiGate High Availability Overview Technical Note
FortiGate High Availability Overview Technical Note FortiGate High Availability Overview Technical Note Document Version: 2 Publication Date: 21 October, 2005 Description: This document provides an overview
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
16-PORT POWER OVER ETHERNET WEB SMART SWITCH
16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------
WatchGuard SSL v3.2 Update 1 Release Notes. Introduction. Windows 8 and 64-bit Internet Explorer Support. Supported Devices SSL 100 and 560
WatchGuard SSL v3.2 Update 1 Release Notes Supported Devices SSL 100 and 560 WatchGuard SSL OS Build 445469 Revision Date 3 April 2014 Introduction WatchGuard is pleased to announce the release of WatchGuard
Packet Capture. Document Scope. SonicOS Enhanced Packet Capture
Packet Capture Document Scope This solutions document describes how to configure and use the packet capture feature in SonicOS Enhanced. This document contains the following sections: Feature Overview
Broadband Phone Gateway BPG510 Technical Users Guide
Broadband Phone Gateway BPG510 Technical Users Guide (Firmware version 0.14.1 and later) Revision 1.0 2006, 8x8 Inc. Table of Contents About your Broadband Phone Gateway (BPG510)... 4 Opening the BPG510's
HP A-IMC Firewall Manager
HP A-IMC Firewall Manager Configuration Guide Part number: 5998-2267 Document version: 6PW101-20110805 Legal and notice information Copyright 2011 Hewlett-Packard Development Company, L.P. No part of this
Chapter 4 Managing Your Network
Chapter 4 Managing Your Network This chapter describes how to perform network management tasks with your ADSL2+ Modem Wireless Router. Backing Up, Restoring, or Erasing Your Settings The configuration
RackSwitch G8264. Application Guide
RackSwitch G8264 Application Guide RackSwitch G8264 Application Guide Note: Before using this information and the product it supports, read the general information in the Safety information and Environmental
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
Command Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 2.0.0 613-000789 Rev. C Copyright 2008 Allied Telesis, Inc. All rights reserved. No part
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version
Managing Software and Configurations
55 CHAPTER This chapter describes how to manage the ASASM software and configurations and includes the following sections: Saving the Running Configuration to a TFTP Server, page 55-1 Managing Files, page
PCoIP Infrastructure Deployment Guide. TER0903005 Issue 1
PCoIP Infrastructure Deployment Guide TER0903005 Issue 1 2 Teradici Corporation #101-4621 Canada Way, Burnaby, BC V5G 4X8 Canada p +1 604 451 5800 f +1 604 451 5818 www.teradici.com The information contained
PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -
Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors
Advanced Traffic Management Guide. ProCurve Switches Q.10.XX. www.procurve.com
Advanced Traffic Management Guide 2510 ProCurve Switches Q.10.XX www.procurve.com ProCurve Series 2510 Switches August 2006 Advanced Traffic Management Guide Copyright 2006 Hewlett-Packard Development
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items
SonicOS 5.9 / 6.0.5 / 6.2 Log Events Reference Guide with Enhanced Logging
SonicOS 5.9 / 6.0.5 / 6.2 Log Events Reference Guide with Enhanced Logging 1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your system. CAUTION:
7750 SR OS System Management Guide
7750 SR OS System Management Guide Software Version: 7750 SR OS 10.0 R4 July 2012 Document Part Number: 93-0071-09-02 *93-0071-09-02* This document is protected by copyright. Except as specifically permitted
Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide
Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished
Web Interface. Security Network Access Port Security. Enabling and Disabling Port Security
Security Network Access Port Security Enabling and Disabling Port Security You can enable and disable security and set the mode of operation on a port using the Port Security wizard. To access the wizard:
Objectives. Background. Required Resources. CCNA Security
Chapter 8 Lab B, Configuring a Remote Access VPN Server and Client Topology IP Addressing Table Device Interface IP Address Subnet Mask Default Gateway Switch Port R1 FA0/1 192.168.1.1 255.255.255.0 N/A
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No
Barracuda Link Balancer
Barracuda Networks Technical Documentation Barracuda Link Balancer Administrator s Guide Version 2.2 RECLAIM YOUR NETWORK Copyright Notice Copyright 2004-2011, Barracuda Networks www.barracuda.com v2.2-110503-01-0503
CCT vs. CCENT Skill Set Comparison
Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification
HP Security Modules. Software Upgrade Guide. Part number: 5998-2259 Document version: 6PW103-20130314
HP Security Modules Software Upgrade Guide Part number: 5998-2259 Document version: 6PW103-20130314 Legal and notice information Copyright 2013 Hewlett-Packard Development Company, L.P. No part of this
P330-ML Version 4.5 Release Notes
Avaya P330-ML Version 4.5 Release Notes 1. Introduction This document contains information related to the Avaya P332G-ML, P332GT-ML and P334T-ML stackable switches that was not included in the User's Guide.
Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement
Prestige 310 Cable/xDSL Modem Sharing Router User's Guide Supplement Domain Name Support Enhanced WAN Setup Remote Node Support PPPoE Support Enhanced Unix Syslog Setup Firmware and Configuration Files
VPNs. Palo Alto Networks. PAN-OS Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks
VPNs Palo Alto Networks PAN-OS Administrator s Guide Version 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 www.paloaltonetworks.com/company/contact-us
Magnum Network Software DX
Magnum Network Software DX Software Release Notes Software Revision 3.0.1 RC5, Inc. www..com www..com/techsupport email: [email protected] This document contains Confidential information or Trade Secrets, or
GLBP - Gateway Load Balancing Protocol
GLBP - Gateway Load Balancing Protocol Gateway Load Balancing Protocol (GLBP) protects data traffic from a failed router or circuit, like Hot Standby Router Protocol (HSRP) and Virtual Router Redundancy
Using Cisco UC320W with Windows Small Business Server
Using Cisco UC320W with Windows Small Business Server This application note explains how to deploy the Cisco UC320W in a Windows Small Business Server environment. Contents This document includes the following
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
Chapter 4 Rate Limiting
Chapter 4 Rate Limiting HP s rate limiting enables you to control the amount of bandwidth specific Ethernet traffic uses on specific interfaces, by limiting the amount of data the interface receives or
AT-S99 and AT-S102 Version 5.0.0 Management Software for the Converteon Media Converter Products. Software Release Notes
AT-S99 and AT-S102 Version 5.0.0 Management Software for the Converteon Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Software