fire separating walls #2



Similar documents
PB301 July Lightweight Building Solutions. Bushfire Protection.

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

5. Financial requirements The relevant financial requirements in the board s policies.

Excerpts from the Canadian National Building Code (NBC)

Dollars & Sense of Compliance!

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

NBC s Rule 7 & 8: Focusing on Residential Buildings

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Rockwool Flexi Insulation Application Guide

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

GYPSUM AREA SEPARATION FIREWALLS GA

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

FIRE RATED GLAZING System Guide

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

How To Build A Two Hour Firewall In Calgary

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

Mark Cramer Inspection Services, Inc.

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Building Permit Information House Relocation

BUILDER S GUIDE FOR TERMITE MANAGEMENT

Mansion on Bourke. 2 Mansion on Bourke Case Study S E R V I C E D A P A R T M E N T S

2014 British Columbia Building Code Changes

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Planning for Bushfire Risk Mitigation General Code

Practice Note

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Termite Management Systems

FS Deck Mounted Skylight Installation Instructions 15-90

Residential Adjustments. Overview 4.1

FIRE AND SMOKE PROTECTION FEATURES

Repair of sheet metal roofs in cyclonic areas

Sample Drawing Package for One and Two Family Dwelling Applications

Energy Company Obligation (ECO): Technical Monitoring Questions

WATER INDUSTRY ACT South Australian Water Heater Installation Requirements. Prepared by the Technical Regulator

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

A Guide To The New Termite Standards (revised 09/02/2001)

Advantages and Disadvantages of Timber Frame Construction

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Composite Panel Firewall Systems

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

14 September Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste St. Paul, MN 55102

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

How To Replace A Roofing System In Florida

EcoTouch Insulation with PureFiber Technology

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Module 3.7. Thermal bridging

Contractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.

Including. Rubershield-Pro. Breather Membrane

Insulating Basements: Part 3 Basement Wall Systems

Multi-layer Insulation Blanket for Roofs

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

FIRE AND SMOKE PROTECTION FEATURES

Repairing storm damaged roofs

A guide to retrofit your home for better protection from a bushfire

Page & Turnbull imagining change in historic environments through design, research, and technology

Standards Committee T echnical Technical Conference

- 5 - Table1. Maximum Compartment Volumes

- Version 2 Total R-value calculations for typical building applications

Smoke Alarm Legislation Frequently Asked Questions

HOW METAL BUILDING INSURANCE COSTS COMPARE TO OTHER BUILDING TYPES

INFORMATION BULLETIN NO.

Building Code of Australia SUPERCEDED. Volume Two. Class 1 and Class 10 Buildings Housing Provisions

How To Repair A Boat Landing Deck With A Boat Bed

Sound Insulation. Handbook

The Florida Building Code

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

TERMITE MANAGEMENT SYSTEMS

ISO Types 1-6: Construction Code Descriptions

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Additions and Alterations

Rev Code of Practice. SIP Technology.

Services Enclosures and Protected Shafts - Maintaining Compartmentation

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

POST AND FRAME STRUCTURES (Pole Barns)

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

THIS GUIDE WAS PREPARED BY THE CYCLONE TESTING STATION WITH SUPPORT FROM NORTHERN TERRITORY, QUEENSLAND AND WESTERN AUSTRALIAN GOVERNMENTS

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

Executive Summary Inclusion of Current Firewall Requirements in NBCC

Solar America Board for Codes and Standards

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

FIRE-RESISTANCE-RATED CONSTRUCTION

A Homeowner s Guide to Building Permits

DIVISION V DWELLING PROGRAM. A. DWELLING ELIGIBILITY -- Risks eligible for the dwelling program are used solely for residential purposes.

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide NEW

Building Control Guidance Note

BSA NEW HOME CONSTRUCTION CONTRACT

Transcription:

210108 fire separating walls #2 ISSUE BSA has identified a number of instances of defective fire separating walls in duplexes, town houses and multi-residential complexes. The system of fire separating walls, as required by the Building Code of Australia (BCA) and as recommended by manufacturers, is not being adequately adhered to in some instances. This publication offers advice for contractors on fire separating wall systems in Class 1a buildings. The definition of a Class 1(a) building is: (i) (ii) a detached house; or one or more attached dwellings, each being a building separated by a fire-resistant wall, including row houses, terrace houses, town houses or villa units. Duplexes and town houses are the most common form of attached dwellings in residential construction. These dwellings have walls that require fire separation between adjoining residences. Cavity of metal roof batten filled with mineral fibre or other suitable fire resistant material. Mineral fibre or other suitable fire resistant material packed to underside of non-combustible roof cladding. Detail showing extent of fire separating wall system with FRL rating extending from footing to underside of non-combustible roof cladding. Timber rafter constructed to either side of fire separating wall system. Fire separating wall system with FRL from footing to underside of non-combustible roof cladding.

Mineral fibre or other suitable fire resistant material. Non-combustible roof cladding Roof battens may pass over separating wall Roof framing Ceiling lining FRL 60/60/60 fire separating wall system Dwelling 1 Dwelling 2 Fire separating wall system from footing to underside of non-combustible roof cladding. Referenced from BCA, V2, Figure 3.7.1.11 Requirements of Building Codes of Australia Class 1a buildings are generally required to be protected from the spread of fire from adjacent buildings. Duplexes and townhouses have separating walls that must also provide fire protection. These fire separating walls must have a continuous fire resistance level (FRL) of 60/60/60 (i.e. a grading rate in minutes for structural adequacy/integrity/insulation) from footing to the underside of a non-combustible roof cover. Where a combustible roof cover is used (i.e. shingles etc), the fire separating wall must extend at least 450 mm above the roof cover. Fire separating walls are designed for masonry or frame construction to specific requirements that must be strictly adhered to and applied continuously. This means that services can penetrate a separation wall if they are installed in accordance with a tested system that is a minimum of -/60/60. Apart from timber roof battens, no combustible material should be allowed to cross a fire separating wall. Timber battens that cross fire separating walls must not be larger than 75 x 50 mm in section. All gaps between the fire separating wall and the roof cover must be packed with suitable fire-resistant material such as mineral fibre, as recommended by the manufacturer. TYPICAL location OF FIRE SEPARATING WALL

Issues of major concern in fire separating walls include: Binders on trusses carried through fire separating walls. Penetrations through fire separating walls that break down the fire rating. Gaps between fire separating walls and the underside of the roof cover that have not been correctly filled with fire resistant material as specified by manufacturers. Gaps between fire separating walls and external wall construction A breakdown of fire separating walls over voids such as roof spaces, verandahs and similar spaces common to more than one dwelling or unit. With a likely increase in the number of multiresidential developments, it is important that builders endeavour to eliminate errors which lead to defective fire separating wall systems. Defects can be avoided by compliance with the requirements of the BCA and adherence to good building practice. fire resistant material should have been packed into this area to prevent fire penetration through the gaps An example of a fire separating wall inadequately finished around roof battens to the underside of concrete roof tiles. Reason for failure: Approved plans and specifications which do not provide details of every construction application related to fire separating wall systems. Building supervisors not providing adequate information and supervision to installers of fire separating wall systems. Builders not adhering to proper fire separating wall installation requirements as specified in the BCA, construction plans and manufacturer s recommendations. Installers or trade contractors not possessing an adequate understanding of how to construct a continuous fire separating wall system.

Penetrations should be installed as per the tested system that achieves -/60/60 rating o Non-combustible roof cladding Fire resistant packing Corrective Measures: Fire separation must achieve compliance with the Performance Requirement of the BCA (compliance with BCA p2.3.1 and be deemed to satisfy BCA p3.7.1.8) p2.3.1 Protection from the spread of fire requires: Roof batten 75 x 50 maximum Fire separating wall system (a) A Class 1 building must be protected from the spread of fire from: (i) Another building other than an associated Class 10 building: and (ii) The allotment boundary, other than a boundary adjoining a road or public space Builders should be aware of construction methods that provide proper fire protection in accordance with building codes and manufacturer s recommendations. Builders should ensure supervisors and installers have plans and specifications that are adequately designed and detailed for fire separating wall construction. Section Fire Separating Wall System Footing or slab-on-ground Reference:DC1 Guide Universal Texts 1998 Supervisors and installers should ensure that fire separating walls provide, in the case of non-combustible roof cover, a continuous fire protection barrier from footing to roof cover, across voids in roof spaces between residences and over eaves and verandas. In the case of combustible roof covers, the fire separating wall should extend 450mm above the combustible material.

Firewall not sealed to eaves creating a gap to adjoining dwelling that fire can penetrate Prevention notes: Strict compliance with the deemed-to-satisfy provisions of the BCA must be adopted for fire separating walls construction. Supervisors and installers should make themselves familiar with the various types of fire separating wall systems (i.e. masonry or frame construction), and with design details which may call for specialised installation techniques, in accordance with manufacturer s recommendations. Builders should maintain full documentation on fire separating wall design details, manufacturer s recommendations, installation compliance certificates (where applicable) and ensure that they can satisfy compliance with building certifiers requirements. Supervisors and installers trained to perform this type of construction can assist builders in preventing unnecessary and costly rectification of defective fire separating wall construction and assist in minimising the number of disgruntled clients of multiresidential complexes. Correctly installed fire resistant material extends the fire separating wall to the underside of the roof tiles. References: The Building Code of Australia Volume Two