GPR Antenna. Conduit. Also known as: Surface/Ground Probing Radar, Surface/Subsurface Penetrating Radar (SPR).



Similar documents
Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts

NDT to Identify Concrete Bridge Deck Deterioration

MONITORING THE GPR RESPONSE OF CURING CONCRETE T. De Souza 1, A.P. Annan 1, J.D. Redman 1, and N. Hu 1 1 Sensors & Software Inc., Mississauga, Canada

Advancements in GPR for a Sustainable Tomorrow

Building Diagnostic Tests as Assessment Tools 診 斷 樓 宇 狀 況 的 測 試 : 樓 宇 檢 驗 的 評 估 工 具

Non-Destructive Testing Methods for Integrity Determination of Concrete Structures

Non-Destructive Testing in Civil Engineering. Herbert Wiggenhauser BAM- Federal Institute for Materials Research and Testing Berlin, Germany

Matt Harris, Golder Associates (NZ) Ltd. The value of geophysics as a non-intrusive method for site characterisation

Thickness estimation of road pavement layers using Ground Penetrating Radar

DRAFT MAINTAINING HOUSTON S STREETS REPAIR, REHABILITATION, RECONSTRUCTION. Using the Full Range of Tools for a Challenging Job

NIST Technology Showcase FutureScan

Chapter 3 Pre-Installation, Foundations and Piers

Ultrasonic Wave Propagation Review

Basics of Reinforced Concrete Design

COBRA WiFi. 2 CHANNEL GPR Detect both shallow and deep pipes

C. Section TESTING LABORATORY SERVICE.

VALIDATION OF NONDESTRUCTIVE TESTING EQUIPMENT FOR CONCRETE FINAL REPORT

2. THE TEORRETICAL OF GROUND PENETRATING RADAR:

Measuring the Condition of Prestressed Concrete Cylinder Pipe

Condition Evaluation of Bridge Deck Surface Structure by Using State of the Art NDT- Techniques

Letter Report Geophysical Subsurface Investigation Activities and Results Suspected Burial Site, Corpus Christi, Texas W.O. No

Presentation outline

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction

Investigation of Unknown Bridge Foundations in Oregon

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Cellular Wireless Antennas

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Safe & Sound Bridge Terminology

EAST LYME HIGH SCHOOL

Product Guide Specification

DIVISION 4300 STORM DRAINAGE

High-Speed Nondestructive Testing and Intelligent Construction Systems

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Session 5D: Benefits of Live Load Testing and Finite Element Modeling in Rating Bridges

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

FY08 SEWER POINT REPAIRS BID TABULATION

APPLICATION OF THERMAL IR IMAGERY FOR CONCRETE BRIDGE INSPECTION

Groundwater exploration WATEX applications with Ground Penetrating Radars. Dr.Saud Amer USGS Dr.Alain Gachet Radar Technologies France

THE ULTRASONIC TOMOGRAPHY TESTS OF CONCRETE IN FOUNDATION SLAB

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Role of Underwater Substructure Inspections in Bridge Management

Pavement Design. Guest Lecturer Dr. Sirous Alavi, P.E. SIERRA TRANSPORTATION Terminal Way, Suite 125 Reno, Nevada 89502

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

SC-07 STORM DRAIN INLET PROTECTION

APPENDIX B. I. Background Information

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

GPR Polarization Simulation with 3D HO FDTD

SECTION 724 PIPE CULVERTS

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Preservation, Repair and Rehabilitation of Concrete Bridges, Pavements and Tunnels in Virginia

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

Proposed Minimum Subterranean Termite Treatment Standards

Moultrie Group Subsurface Geophysical Surveys

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Roofing & Waterproofing Forensics for the 21 st Century. Peter Brooks, President

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

SECTION EARTH MOVING

POTENTIAL AND LIMITATIONS OF THE ARCHAEO-GEOPHYSICAL TECHNIQUES

hs2 Ground A non-technical guide

Moving Small Mountains Vesuvius Dam Rehab

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Chapter 7: Pavement Rehabilitation 7-1 Asphalt Pavement Overlays 7-1 Surface Preparation Methods 7-2 Concrete Pavement Preparation 7-3 Recycling

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Emerging NDE Technology for Aging Aircraft Large Area Scanning To Small High Resolution Systems Maintenance Planning Tools

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Mobile Home Pre-Inspection Checklist

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

Nondestructive Testing and Evaluation of Steel Bridges

National Archives and Record Administration

INSPECTION FINDINGS. for. Paragon Condominiums 2102 W 31 st Avenue Denver, Colorado. Inspection Date: August 8, Perfonned By: Drew Schneider

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

State of Connecticut Department of Public Health RADON PROGRAM

Rehabilitation Strategies for Bonded Concrete Overlays of Asphalt Pavements

[TECHNICAL REPORT I:]

Wastewater Capital Projects Management Standard Construction Specification

Bridge Type Selection

Installation Instructions Hustler 6-BTV Trap Vertical

Technical Notes 3B - Brick Masonry Section Properties May 1993

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers

Remote Monitoring of Soil Pressures on Bridge Footings

Chapter 7 Plumbing Connections

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

High Strain Dynamic Load Testing of Drilled Shafts

Transcription:

GPR Method N D E G R O U N D P E N E T R A T I N G R A D A R [ G P R] A PPLICATION The Ground Penetrating Radar (GPR) method is primarily applied to locate and measure the depth of steel reinforcement, post-tensioning and prestress tendons or ducts, and embedded metallic or plastic conduits in concrete slabs, walls, or structural members. The GPR method is also applied to define areas of corrosion in reinforced bridge decks or other elements, determine thicknesses of members with little or no reinforcement, measure pavement thickness and properties, and locate subgrade voids below concrete slabs or behind retaining walls. GPR scans can be performed on concrete elements, standard framed or masonry walls, concrete and asphalt pavements, and soil. GPR is used for many geophysical applications as well. The GPR method is a wave propagation technique that transmits and receives electromagnetic waves (EM or radio waves). The technology is usually used in zero-offset reflection surveys but can be used in direct transmission. Many antennas are available ranging in center frequency from 25 to 1500 MHz. For NDE applications, the selection of antenna is dependent on the desired feature resolution and depth of penetration and the typical range is 400 to 1500 MHz. GPR Antenna Conduit Rebar Also known as: Surface/Ground Probing Radar, Surface/Subsurface Penetrating Radar (SPR). S TANDARDS Standards for the GPR method include AASHTO TP-36 and ASTM D6087 for evaluating asphalt-covered concrete bridge decks, ASTM D6432 for general geophysical and NDE applications of GPR, ACI 228.2R for NDE applications in concrete structures, and AASHTO PP 40, ASTM D4748, FHWA-HIF-00-015, NCHRP Synthesis No. 255, SHRP C-101 and SHRP Catalogue No. 4008 for pavement evaluations. See end of document for full references. 12401W. 49th Ave., Wheat Ridge CO 80033 7USA 303.423.1212

GPR F IELD I NVESTIGATION GPR data are collected in either a 2-D (distance and time) or 3-D (x, y, and time) fashion, depending on the application. The scan patterns for clearing a proposed corehole in a concrete slab for 2-D and 3-D investigations are shown in the figures below. For feature mapping over large areas with little known information, 3-D scanning is typically utilized. A 3-D investigation compiles multiple parallel and perpendicular 2-D lines into a panel or panels. 2-D scanning is often reserved for single point locates or for situations in which a good portion of the field conditions are known. ACCESS Only one surface needs to be accessible for the antenna placement. There are no personnel evacuation requirements with GPR as there are with X-ray (radiography). Scanning along the surface of the test members allows identification of reflection from buried objects along the scan line. The scan path test surface needs to be free of obstacles and debris and clean. A borehole GPR antenna requires typically a 2-4 inch diameter PVC access tube. COLLECTION OF DATA In a GPR test, the antenna is moved continuously across the test surface and the control unit collects data at a specified distance increment. In this way, the data collection rate is independent of the scan rate. Alternatively, scanning can be performed at a constant rate of time, regardless of the scan distance. Single point scans can be performed as well. Data is reviewed on-screen and in the field to identify reflections and ensure proper data collection parameters. D ATA R EDUCTION P ROCESSING T ECHNIQUES For a 2-D investigation, features and their locations are identified on-screen and marked in the field. For a 3-D investigation, data are downloaded either on-site or in our offices to processing clients. The data processing steps may include a variety of geophysical algorithms (initially developed in the field of seismology); the steps performed depend on the data characteristics and project goals. For embedded conduit location, 3-D GPR data are typically migrated and interpolated from scan to scan to produce plan view depth slices, analogous to X-ray images. I NTERPRETATION O F D ATA GPR tests rely on reflection of electromagnetic waves. The results from a GPR test can be viewed on the screen in terms of a plot of time or depth versus scanning distance (2-D investigation). The two-way travel time is used to calculate the reflector depth assuming that the velocity of the penetrated material(s) is reasonably estimated or known from correlations with destructive coring at selected locations ofthe site. This velocity depends on the material relative dielectric constant. GPR depth calibrations on concrete are often performed from element thickness correlation with Impact Echo (IE) data. For a 3-D dataset, buried features are identified by viewing plan or perspective views of individual depth slices or a cube/block of data. [ Page 2 ]

E FFECTIVENESS The effectiveness of GPR scanning and interpretation is highly dependent on the existing field conditions. Heavily reinforced members may shield radar signals from deeper material or features. Deep, small diameter features are more difficult to detect than shallow, large diameter features. Moisture content and clayey materials limit signal penetration. Ambient EM noise may distort data. For depth determination, velocity estimation must be performed from a location of known thickness. Typical accuracies for linear feature centerline locations are ± 0.25 to ±1.0 inches or less. E XAMPLE R ESULTS Example results for various applications of both 2-D and 3-D scanning: STRUCTURAL - PT TENDONS The results of 3-D scanning to identify post-tensioning (PT) tendons in a 12 inch thick elevated concrete floor slab are presented in the figure to the right. The x-trending tendons were spaced at nominally 3 ft. A group of four y-trending tendons pass over a column at x = 22-23 ft. The tendons were successfully located and allow for safe coring of approximately 25 holes for a restaurant kitchen remodel. STRUCTURAL - BURIED CONDUIT A pair of 1.75 inch diameter conduits below a 4-6 inch thick concrete floor slab were found with 3-D GPR scanning at a hospital remodel. The slab varied in thickness from 4-6 inches and contained a mat of welded wire fabric reinforcement with 6 inch spacing. The 6 inch deep conduits housed critical 480 volt power supply lines to the hospital building. The scanning was performed to locate any embedded or buried features to allow for safe slab cutting of trenches for plumbing installation. Paired 1.75 inch diameter plastic electrical conduits, 6 inches deep below slab. [ Page 3 ]

DEPTH [foot] at v=3.8[inch/ns] GPR N D E E XAMPLE R ESULTS cont. STRUCTURAL - CMU WALL A 2-D GPR scan was performed along a new concrete-masonry unit (CMU) perimeter security wall for a country club. The scanning was performed confirm the presence or absence of vertical rebar and to distinguish between grouted and hollow cells. The results were confirmed with destructive chipping and a repair plan was designed for the wall. DISTANCE [FOOT] Grouted cell and missing rebar TIME [ns] Ground Penetrating Radar [GPR] Results for Alpine Dam Spillway Slab Impulse Responce [Slab IR] Relative Mobility Results for STRUCTURAL - SUBGRADE VOIDS for Alpine Dam Spillway GPR was combined with the Slab Impulse Response (Slab IR) method to locate subgrade voids below an alpine dam spillway (see references for full text). [ Page 4 ] OLSON ENGINEERING, NC., INC., 519112401 Ward Rd., W. 49th Suite Ave, 1, Wheat Ridge, CO 80033-1936 USA USA 303.423.1212 303.423.1212

E XAMPLE R ESULTS cont. C ONCRETE P AVEMENT A 3-D GPR investigation was performed on an outdoor concrete parking lot after isolated cracking had occurred upon heavy vehicle/machinery loading. The slab thickness for each scan was semi-automatically identified and exported from the GPR processing software. The tabulated data were then contoured. The slab design thickness was 6 inches and the full western 40 feet was designed to be 8 inches. The critically thin threshold was designated as 4 inches. [ Page 5 ]

F IELD I NVESTIGATION A SPHALT R UNWAY Results from GPR tests performed on runways and taxiways of an airport to determine the thickness of the asphalt layers. The antenna was mounted to a van trailer hitch for fast data collection. F OUNDATIONS GPR scanning was performed at the base of a wall to locate steelwrapped concrete foundations (caissons) behind the wall. The results of 2-D scanning are presented in the figure to the right. [ Page 6 ]

R EFERENCES Standards and Governmental Reports AASHTO PP 40, Application of Ground Penetrating Radar (GPR) to Highways. AASHTO TP-36, Standard Test Method for Evaluating Asphalt-Covered Concrete Bridge Decks Using Pulsed Radar. ACI 228.2R, Nondestructive Test Methods for Evaluation of Concrete in Structures, ACI Manual of Concrete Practice, Part2, Construction Practices and Inspection, Pavements, ACI International. OLSON ENGINEERING P UBLICATIONS Application of a Combined Nondestructive Evaluation Approach to Detecting Subgrade Voids Below A Dam Spillway", Larry D. Olson, P.E., David A. Hollema, Environmental and Engineering Geophysical Society (EEGS), Symposium on the Application of Geophysics to Engineering and Environmental Problems (SAGEEP), presented at Colorado Springs, Colorado, February 23, 2004. ASTM D4748, Standard Test Method for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar, Book of Standards Volume 04.03, ASTM International. ASTM D6087, Standard Test Method for Evaluating Asphalt-Covered Concrete Bridge Decks Using GROUND Penetrating Radar, Book of Standards Volume 04.03, ASTM International. ASTM D6432, Standard Guide for Using the Surface Ground Penetrating Radar Method for Subsurface Investigation, Book of Standards Volume 04.09, ASTM International. FHWA-HIF-00-015, Ground Penetrating Radar for Measuring Pavement Layer Thickness. NCHRP Synthesis No. 255, Ground Penetrating Radar for Evaluating Subsurface Conditions for Transportation Facilities, A Synthesis for Highway Practice, TRB Synthesis Studies. SHRP C-101, Condition Evaluation of Concrete Bridges Relative to Reinforcement Corrosion, Vols. 1-8. SHRP Reports S-323 through S-330. SHRP Catalogue No. 4008, Pavement Thickness Software Using Radar. O LSON E NGINEERING, INC. CORPORATE OFFICE: 12401 W. 49th Ave. Wheat Ridge, CO 80033-1927 USA Phone: 303.423.1212 Fax: 303.423.6071 www.olsonengineering.com www.olsoninstruments.com info@olsonengineering.com