ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):



Similar documents
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Module 2.2. Heat transfer mechanisms

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

SELECTIVE GLAZING FOR SUN CONTROL

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

3-D Modeller Rendered Visualisations

Energy Efficiency in Buildings

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

A Roof Integrated Solar Heating System Without Storage

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Integrated Solar Radiant Systems

THERMAL LOSSES Thermal Losses Calculations

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

RESNET National Rater Test Study Guide Outline

Nondestructive Evaluation of USCG Hawkins Pt. Road Curtis Bay, MD Provided by: HurleyIR

MCQ - ENERGY and CLIMATE

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

New Thermal Architecture For Future Green Data Centres

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia

Unbeatable energy efficient glass curtain wall system

Directorate for the Built Environment Building Standards Division

The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

Product description NCC Data Center

City of Houston Code Enforcement COOL ROOF CODE

AIRCONDITIONING Cooling Loads Calculations

SOLAR ENERGY How much strikes the earth? How much can my building get? When is it too much?

Green Architecture and Construction

Evaluation of Window Energy Rating Models for Different Houses and European Climates

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

Infrared Moisture Detection

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

Solar Thermal Systems

Challenging the possibilities

Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Aquitaine Bordeaux Campus

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

ResearcH JournaL 2009 / VOL

WATERPROOF PHOTOVOLTAIC SYSTEM

Energy Efficient Hospital Patient Room Design: Effect of Room Shape on Windowto-Wall Ratio in a Desert Climate

New technical solutions for energy efficient buildings

Ceiling Fans. 1 Introduction. V entilation I nformation P aper n 13

Parametric Analysis of School Classroom Typologies' Energy Performance

Cloud Radiation and the Law of Attraction

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Physics 1010: The Physics of Everyday Life. TODAY Black Body Radiation, Greenhouse Effect

The Effect of High SRI Roofing Finishes Across Climate Zones in the U.S. John Lee

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY

Sustainable water heating solutions through solar systems

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

A NEW CONCEPT OF A HYBRID STORAGE SYSTEM FOR SEASONAL THERMAL ENERGY STORAGE IN SOLAR DISTRICT HEATING

Strategies for an Environment Friendly Low Energy Retrofitting of a Health Care Facility in the Hot Climate of UAE

Solar Energy and Green Roofs

Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows

Solar heat reflective paint & coatings using 3M Glass Bubbles

Adaptive strategies for office spaces in the UK climate

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

IDA Early Stage Building Optimization (ESBO) User guide

Preventing Ice Dams on Roofs

Material test chamber with mechanical convection

Building Information Modelling (BIM); How it Improves Building Performance. R.P. Kumanayake Lecturer, Department of Civil Engineering

Q1. (a) The graph shows the temperature inside a flat between 5 pm and 9 pm. The central heating was on at 5 pm.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

SWISSOLAR 2104 TASK 44 SOLAR AND HEAT PUMP SYSTEMS

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

ROOFS, SNOW AND ICE DAMS

Protocol for the Certification of Energy Simulation Software: First edition, December 2009

COMMERCIAL BUILDING APPLICATIONS

Using the sun to generate electricity

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool

ZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS. UK Building Regulations and EU Directives

Protocol for the Certification of Energy Simulation Software: Second edition, September 2011

Ecofys VII U-Values for Better Energy Performance of Buildings

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Impact-Resistant Windows and Sliding Glass Doors

Transcription:

ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM) Date : 14/04/2014

ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes Regional Head M: +971 50 727 6787 E: Leonard.Fernandes@derbigum.com DERBIGUM MIDDLE EAST 709, Al Thuraya Tower 2 Dubai Media City P.O Box 500717 Dubai, UAE www.derbigum.com DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM) Date : 14/04/2014 Energy audit and dynamic simulation software conceived with the scientific collaboration of 3E sa (Headquarters) Rue du canal 61 B1000 Brussels 3E France (Branch) 8, rue Maréchal de Lattre de Tassigny F59000 Lille 3E France (Office) 80 Bd. du Maréchal Leclerc F31000 Toulouse www.3e.eu DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 2

1. PREAMBLE 1.1 INTRODUCTION Thermal and energy Audit DERBIBRITE NT flat roof DERBIGUM introduced DERBIBRITE NT on the market of flat roofs as a «passive cooler» solution with a high emissivity and reflectance for flat roofs, in order to reduce the cooling demands or to increase the interior comfort during hot periods in service or industrial buildings. 3E is an engineering & consulting company, specialized in energy savings and renewable energies. The active involvement in international projects and in the development of research activities allows 3E to guarantee a high level of knowledge in technological innovations. Due to its activities in the field of energetical efficiency in buildings, 3E developed a unique expertise in the use of thermal dynamic simulation software for buildings and in the development of tools. In order to evaluate the energetical and thermal benefits provided by DERBIBRITE NT, 3E developed a dynamic simulation tool allowing to calculate the energetical demands of a building. Furthermore, this tool allows DERBIGUM to evaluate quantitatively the effect of DERBIBRITE NT on every building complying with the basic criteria. 1.2 PRESENTATION OF THE METHOD A complete and detailed analysis of the thermal behaviour of a building requires a specific attention that often resorts to using computer simulations (thermal dynamic simulation software ). The tool developed by 3E for this project is based on the TRNSYS software, worldwide considered as reference tool for thermal dynamic simulations of energetical systems and buildings. The tool created for this project allows to simulate, hour by hour, the thermal transfers from the building taking into account the exterior climatic conditions of the site (temperatures, sun radiation, wind speed, ) and the characteristics of the building (internal benefits, composition of walls, heating, cooling ). Various temperature results, energetic needs, or other figures can be edited for every hour during the year. Certain hypotheses have been adopted in order to simplify for example the building geometry, however without modifying the accuracy of the results. Additional information regarding the software and the used numeric model can be found in the appendix. DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 3

2. PRESENTATION OF THE PROJECT This case study concerns an industrial building, located in the United Arab Emirates. The present document groups the thermal results obtained by digital simulation of the existing modelized situation compared with the projected situation improved by means of the passive cooler DERBIBRITE NT. The data and hypotheses for the simulation are indicated in the present document. This study is presented as an Energy Audit. 2.1 DESCRIPTION OF THE BUILDING The project details used for the simulation are indicated below. 2.1.1 Main data of the building Length building 200 m Width building 50 m Roof surface 10.000 m² Height 8 m Roof slope 2 % 2.1.2 Characteristics of the roofs for the 2 situations (existing and projected) Figure 1: Stratigraphy of the roof complex (reference) Reference situation (typical roof) : inverted roof covered with concrete tiles 1. Concrete tiles. 2. Protection and sliding layer. 3. (XPS) Extruded polysterene. 4. Protection layer 5. Waterproofing layer. 6. Concrete deck. DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 4

Figure 2: Stratigraphy of the roof complex (alternative) Alternative proposal : warm roof with uncovered DERBIBRITE NT waterproofing membrane 1. DERBIBRITE NT «passive cooler» 2. (PUR) Polyurethane or (PIR) Polyisocyanurate, glued by means of DERBITECH FA. 3. DERBIPRIMER S, bituminous primer. 4. Concrete deck. Schedule 1 : Roof properties Typical inverted roof (estimation) Solar reflectance Thermal emissivity +/-15% 90% DERBIBRITE NT alternative 81% 81% DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 5

2.1.3 Properties of walls for both situations The walls have an identical composition in both the existing and the projected situation. Each wall is characterized by its orientation, its composition, as well as by the importance of the «secondary» surfaces such as the doors (S2) and the windows (S1). Schedule 2 : Wall properties WALL 1 WALL 2 WALL 3 WALL 4 Orientation North East South West Composition Identical composition for all the walls : Corrugated aluminium sheet, PU 50 mm, interior finish L1 [m] 50 200 50 200 H1 [m] 8 8 8 8 S1 [m²] 0 50 25 50 S2 [m²] - - - - S1 (windows): double glazing ; surfaces are given as an example S2 (doors): can be considered as negligible in comparison with the global opaque surface. 2.2 HYPOTHESES FOR USING CONDITIONS Interior using conditions: factory (light bench work), 90 W. Occupation of the building: production 6 days/ week; 2 shifts a day Air conditioning : day setting temperature 22 C, night setting temperature 26 C No mechanical ventilation Schedule 3 : Properties of internal gains Staff Lighting Computers Other Maximal output [W/m²] - 10 W not significant 5 W (*) Occupation density [number of people] 50 persons - - - (*) Estimated output from production equipment DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 6

3. RESULTS AND ANALYSIS For the present audit study, we analysed 3 cases with distinct roof insulation levels. The considered insulation levels are given in the table below. CASE 1 CASE 2 CASE 3 Inverted roof (reference) XPS 50 mm XPS 80 mm XPS 100 mm DERBIBRITE NT warm roof (alternative) PU 50 mm PU 80 mm PU 100 mm 3.1 RESULTS CASE 1 3.1.1 COOLING DEMAND Schedule : Monthly cooling demand, within the building considering the simulation of roof constructions as detailed below. Comments : Reference (1st column) : represents the inverted roof construction (XPS 50 mm) Case 1 (2 nd column): represents a warm roof construction with a light grey roofing material (PU 50 mm) Case 2 (3rd column): represents a warm roof construction with DERBIBRITE NT (PU 50 mm) DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 7

3.1.2 RESULTS AND ANALYSIS : COOLING ENERGY SAVING Summary of analysis (CASE 1) Annual cooling energy demand Inverted roof Warm roof solution with DERBIBRITE NT kwh/yr +/- 892.300 +/- 619.900 Annual energy saving kwh/yr 272.400 Cooling saving in percentage % 30,53% 3.2 RESULTS CASE 2 3.2.1 COOLING DEMAND Schedule : Monthly cooling demand, within the building considering the simulation of roof constructions as detailed below. Comments : Reference (1st column) : represents the inverted roof construction (XPS 80 mm) Case 1 (2 nd column): represents a warm roof construction with a light grey roofing material (PU 80 mm) Case 2 (3rd column): represents a warm roof construction with DERBIBRITE NT (PU 80 mm) DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 8

3.2.2 RESULTS AND ANALYSIS : COOLING ENERGY SAVING Summary of analysis (CASE 2) Annual cooling energy demand Inverted roof Warm roof solution with DERBIBRITE NT kwh/yr +/- 752.700 +/- 562.900 Annual energy saving kwh/yr 189.800 Cooling saving in percentage % 25,22% 3.3 RESULTS CASE 3 3.3.1 COOLING DEMAND Schedule : Monthly cooling demand, within the building considering the simulation of roof constructions as detailed below. DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 9

Comments : Reference (1st column) : represents the inverted roof construction (XPS 100 mm) Case 1 (2 nd column): represents a warm roof construction with a light grey roofing material (PU 100 mm) Case 2 (3rd column): represents a warm roof construction with DERBIBRITE NT (PU 100 mm) 3.3.2 RESULTS AND ANALYSIS : COOLING ENERGY SAVING Summary of analysis (CASE 3) Annual cooling energy demand Inverted roof Warm roof solution with DERBIBRITE NT kwh/yr +/- 699.700 +/- 542.000 Annual energy saving kwh/yr 157.700 Cooling saving in percentage % 22,54% 4. CONCLUSION The results of this study, based on a numerical simulation, confirm the benefits and positive effect of the highly reflective DERBIBRITE NT membrane on the energetical balance of the building. The DERBIBRITE NT clearly acts as a «passive cooler» when used as an exposed layer in a warm roof construction. Considering the parametres and hypotheses considered for this study, the following savings on cooling energy consumption could be achieved with our proposed alternative roof construction, when compared to the reference inverted roof: CASE 1 (50 mm insulation) : energy saving of over 30% CASE 2 (80 mm insulation) : energy saving of over 25% CASE 3 (100 mm insulation) : energy saving of over 22% DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 10

5. DERBIBRITE NT TECHNICAL SHEET DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 11

6. DERBIBRITE NT - PROJECT REFERENCES YAMAHA European Distribution Centre (Netherlands) HENKELL Wiesbaden (Germany) ABB (Italy) SWATCH (Switzerland) PORSCHE (Italy) DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 12

LAMBORGHINI (Switzerland) San Antonio City Hall (USA Texas) UN City (Denmark) Exhibition and Convention Centre (Sweden) Life Care Hospital (USA) DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 13

6. APPENDIX A. GLOSSARY What happens to the fraction of energy that is not reflected by the surfaces The solar energy that was not reflected is converted in heat that is dispersed and transfered under 3 forms: conduction, convection and radiation. The conduction and the convection generally lead the heat towards the interior air of the volume underneath the roof. The heat that is not dispersed via conduction and/or convection is radiated from the roof under the form of an infra-red radiation (lower range IR). This property of radiating the heat is called «emissivity». Energy Star... An American program monitored by the Environmental Protection Agency (EPA), promoting the conservation of Energy and the natural resources associated with the production of energy. Solar reflectivity... Quantity of solar energy that a given material reflects towards the atmosphere. The Albedo term is also used to define this effect. Usually expressed in %. The white surfaces offer the highest solar reflectivity, while the black ones the lowest. This is a surface property. It is measured according to the ASTM 1549 standards. Thermal emissivity... Quantity of energy that a given material emits due to its proper heat and temperature. Usually noted in %. This % of energy that was not reflected is radiated in the environment. This is a surface property. The higher the emissivity, the faster a given material is going to cool off by itself through radiation and the lesser heat will be transferred to the surrounding air through convection. The emissivity is measured according to the standard ASTM E 4308-71 method A. B. PRESENTATION OF THE E-BRITE SOFTWARE The tool developed by 3E is based on a scientific core TRNSYS, worldwide considered as the reference tool for thermal dynamic simulations of energetical systems and buildings. Various institutes, research organisms or companies use this software in order to study and validate the problems of the building s physics. TRNSYS (TRaNsient SYstem Simulation Program) is a modular simulation software. It is supplied with a number of basic modules (about 50) and it offers the possibility to the user to create himself his proprer components. Thanks to this modular approach, TRNSYS is extremely flexible to modelize thermal and energetical models according to different complexity levels. These simulations are linked with: Exterior : meteorological conditions Interior: different scenarios of occupation The use of different kinds of energy The tool created for this project allows to simulate, hour by hour, the thermal transfers from the building taking into account the exterior climatic conditions of the site (temperatures, sun radiation, wind speed, ) and the characteristics of the building (internal benefits, composition of walls, heating, cooling ). Various temperature results, energetical needs, or other figures can be edited for every hour during the year. Certain hypotheses have been adopted in order to simplify for example the building geometry, however without modifying the accuracy of the results. DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 14

C. VALIDATION OF E-BRITE SOFTWARE In order to validate the results generated by the E-BRITE software, various test-cases have been studied by the engineering office 3E and compared with the VIRTUAL ENVIRONMENT software, other reference software in the field. The results have demonstrated the reliability of the model based on TRNSYS, and the minor differences are due to the different approach of hypotheses in the calculation method. D. INTERPRETATION OF THE RESULTS OF THE AUDIT This «roof» audit is based on information received on the building structure, thermal conditions, the conditions of use and technical equipments. As specific information may be missing or might be subject to interpretation, it is occasionally necessary to calculate with hypotheses. Furthermore, the simulation software cannot always take account of all the different segments in a building nor consider specific or irregular shapes. As a result, the conclusions of this energy audit have to be considered as indicative. DERBIGUM Bergensesteenweg 32 B-1651 LOT T. +32 (0)2 334 87 00 F. +32 (0)2 378 14 69 info@derbigum.com - www.derbigum.com 15