Applications for building permits will not be reviewed until all of the required information has been submitted.

Similar documents
City of Elk River BASEMENT Office Use Only

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

APPLICATION FOR NEW CONSTRUCTION

Single Family Residential Basement Finish

How To Build A Basement House

BUILDING PERMIT SPECIFICATIONS

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

City of St. Charles Basement Finish or Remodel

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Does Wall Township require an inspection by the building department on resale of a home?

Basement Development Construction requirements for the development of basements in residential dwellings.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

FINISHED BASEMENT REQUIREMENT GUIDE

HOMEOWNER S PERMIT GUIDE

PDmB, Inc. Definitions

BUILDING SAFETY UNIT

FINISHED BASEMENT SUBMITTAL GUIDE

Building Information Packet

How To Make A House Safe

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Georgia Association of Home Inspectors

2. What building projects are exempted? (permit not required)

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

CONSTRUCTION PERMIT APPLICATION AND INSTRUCTIONS (Permit Application follows instructions)

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Inspecton Report. Property Address:

PLUMBING PERMIT REQUIREMENTS AND CHECKLIST

Residential Building Permits

City of Peterborough

RESIDENTIAL WINDOW REPLACEMENT

Residential Plan Routing Information

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

Uniform Construction Code (UCC) Building Permit Application Package

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Residential Building Permit Process

PROPOSED Plumbing Fee Ordinance Amendment

Building Permits: When are they required?

Development Services City of Lawrence, KS

Home Inspection Report

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Inspection Tech. (330) Inspected By: Aaron Westerburg

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

RRIO Checklist. Use of checklist: Definitions: Limitations

Residential Building Plan Review Additions and New Home Construction

TOWN OF DAVIE BUSINESS TAX RECEIPT 6591 ORANGE DRIVE DAVIE, FLORIDA PHONE: FAX:

Typical Finished Basement Details

Pre-Drywall Inspection Report

GENERAL WIRING RULES FOR HOUSES

Minimum Housing and Health Standards

WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive

Holz Choices & Specifications

Typical Finished Basement Details

ESTIMATING PLUMBING, HEATING, VENTILATING, AND AIR CONDITIONING (HVAC), AND ELECTRICAL WORK

COMMERCIAL BUILDING PERMIT INFORMATION

C I T Y O F P E A R S A L L

Building Permit Application

BUILDING PERMIT RESIDENTIAL BASEMENT FINISH

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

( Staple Upper Right Corner ) MINNEAPOLIS TRUTH-IN-SALE OF HOUSING DISCLOSURE REPORT

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

The City of Basehor, Kansas

Crawford Inspection Services C.C.B. #

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

Village of Airmont APPLICATION FOR BUILDING PERMIT INSTRUCTIONS

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Self-Home Inspection Checklist

South Carolina Home Inspector Standards of Practice

INFORMATION BULLETIN NO.

2014 British Columbia Building Code Changes

Rental Property Safety Inspection Checklist

SUMMARY OF WORK FOR GENERAL CONTRACTOR

October 5, 2015 Dear Client,

Arapahoe County Residential Water Heater Installation and Inspection Guide

SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES

City of Oviedo Commercial Shell Building Permit Application Guidelines

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

I NI NP R Inspected Items

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Total Home Inspection Checklist

Bureau Veritas Contact Information

Structure Survey Findings:

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

HOUSING QUALITY STANDARDS (HQS)

Transcription:

NOTICE: Applications for building permits will not be reviewed until all of the required information has been submitted. Once all items are submitted a minimum of ten (10) working days are required to process the application. Notice Basement Finish & Remodel 1/10/2012

City Of Wyoming - Department Of Building Safety Requirements for Application for Building Permit BASEMENT FINISHES & REMODELS THAT DON T INCREASE BUILDING SIZE APPLICATIONS WILL NOT BE PROCESSED IF ALL FORMS ARE NOT COMPLETED Items to be submitted with application: a. Completed building permit application form. b. 2 sets of the Building Plans. The use of each room must be labeled. c. Completed plumbing permit application if any plumbing work is proposed. d. Completed heating permit application if any ventilation work is proposed (including extending duct work or installing exhaust fans). e. Septic Compliance Inspection If the property is located in a shoreland district (within 1000 feet of a lake or within 300 feet of the Sunrise River) or if the work includes adding a bedroom, a septic system compliance inspection must be done. If the system was installed within the last 5 years the Certificate of Compliance is still valid. If the system was inspected within the last 3 years, the Certificate of Compliance is still valid. The system must have been designed and installed to support the additional bedroom(s). If the system is not large enough, or is failing, a septic permit application to replace or expand the septic system must be included with the Building Permit Application. If all of the requirements of the Minnesota State Building Code and of the City of Wyoming's Ordinances have been met, a building permit will be issued. Your building permit does not include the inspection of electrical work. A separate Request for Electrical Inspection form with the required fees must be submitted to the Board of Electricity at or before commencement of any electrical installation that is required by law to be inspected. Gene Boyle does electrical inspections in the City of Wyoming. He can be reached at (763) 633-9148, 7:00 8:30 am. ***Minimum 24-hour notice for inspections. ***Permit number & address must be furnished when requesting an inspection. ***The building permit inspection card and the approved plans must be on job site at all times. If the building permit inspection card is not posted, the requested inspection will not be done. ***The job is not complete, and the space cannot be used until all of the required inspections are approved. Basement Finish & Remodel Bldg Permit App Requirements revised 01/10/12

City of Wyoming- Department of Building Safety BASEMENT FINISH & REMODELS Building Codes and City Ordinances provide minimum standards for creating an environment of health and safety for all Wyoming residents. Permits 1. A signed, completed building permit application form. 2. Two (2) copies of plans showing proposed layout and materials. Plans shall be drawn to scale and shall include the following information. a. A floor plan indicating: Location of lower level or basement exterior walls. Location of all existing and proposed interior walls of lower level or basement. Name of each existing and proposed room. Location and sizes of windows and doors. Wall construction materials. Location of existing or proposed plumbing fixtures, including furnace and water heater. Location of stairway, fireplaces, etc. Location of smoke detector(s). Location and size of supply and return air ducts. b. A cross section plan indicating: Proposed finished ceiling height. Wall, floor, and ceiling finish materials. Existing and proposed insulation and vapor barrier. Rise, run and headroom on stair. Required Inspections: 1. Framing/Insulation: To be made after all framing, insulation, and ductwork are in place and the rough electrical, plumbing, and heating systems are approved. 2. Final: To be made when work is complete, having final approval of any heating, electrical, or plumbing work. 24 HOUR NOTICE IS REQUIRED FOR ALL INSPECTIONS Framing: 1. Properly sized beams and headers must be used in structural bearing conditions. Specify intended sizes of such beams and headers on plans. 2. Enclosed usable space under stairs must be protected on the underside with 1/2 - inch thick gypsum wallboard or equivalent. 3. Treated wood or decay resistant bottom plates are required where in contact with concrete floors. Insulation: 1. Foam plastic (rigid) insulation shall be protected on the interior by not less than ½ inch thick gypsum board, or the foam must be of an approved type. Basement Remodels 2006 IRC Revised 1/10/12

2. Fiberglass insulation must be covered on the interior by not less than a four (4) mil thick vapor retarder. Unfinished vapor retarders require a flame retardant type poly. Mechanical / Plumbing: 1. Furnace rooms must be provided with outside combustion air. 2. Joints, regulators, or fittings in gas piping may not be concealed within the wall or ceiling construction. 3. Each water closet stool shall be located in a clear space not less than 30 inches in width and have a clear space in front of the water closet stool of not less than 24 inches. 4. Each bathroom shall be provided with an operable window or a powered exhaust fan which vents to the exterior. Smoke Detectors: Smoke detectors are required for the entire house when remodeling or finishing a basement. Smoke detectors must be in each bedroom, in corridors leading to bedrooms and on every level of the home. Smoke detectors must be hard wired with battery backup in the newly remodeled areas. Smoke detectors in existing areas may be solely battery powered. Smoke detectors should be interconnected if possible. Windows: Each bedroom shall be provided with an emergency escape or rescue widow (see attached handout). Ceiling Height: The minimum permitted ceiling height in habitable rooms (meaning finished family rooms and bedrooms) is seven (7) feet. General Notes: 1. The reviewed plans and the Inspection Record Card shall be made available to the inspector during inspections. It shall be posted in a prominent location in the area of construction. 2. Separate permits are required when installing electrical wiring, heating equipment, or plumbing fixtures. Contact the Building Official for information regarding plumbing and heating permits. Contact Gene Boyle, the state electrical inspector at (763) 633-9148 between the hours of 7:00 A.M. and 8:30 A.M. for electrical permits and inspections. 3. Call (651) 462-4947 between the hours of 8:00 A.M. and 4:30 P.M. to arrange for building inspections. Please provide the permit number with your request. NOTE: For specific code requirements, please contact the Building Official. Questions regarding design and cost should be referred to a professional builder or architect.

City Of Wyoming - Department Of Building Safety MINIMUM SIZE FOR RESCUE ESCAPE WINDOWS FROM SLEEPING ROOMS IRC Section R310 The Minnesota State Building Codes provide minimum standards for creating an environment of health and safety for all residents. Permits required A building permit is required for replacing or installing new windows. Escape windows must meet all three of the following minimum sizes for clear openable area: 20 inches wide, 24 inches high, 5.7 square feet (Exception: Grade-floor openings may have a minimum net clear opening of 5.0 square feet). Basement window well for escape rescue windows This handout is written as a guide to common questions and problems. It is not intended nor shall it be considered a complete set of requirements. Escape Windows Handout.doc Revised 9/30/11

City Of Wyoming - Department Of Building Safety Application For Building Permit (Finish Basements & Remodels that don t increase building size) NOTE: THERE IS A PENALTY FOR CONSTRUCTION PRIOR TO ISSUANCE OF THE PERMIT. ALL FEES MUST BE PAID. Site Address Please Print address city State zip Owner Name Legal Description Lot Block Subdivision Phone Sec Twp 33N Range 21W Zone PIN (Tax) Number _R21. Builder/Contractor Name License # PLEASE PRINT Contact Person Address address city State zip Phone Type of work Remodel Repair Finish Type of Construction Wood Masonry Steel Use of Rooms Finished or Remodeled Area Size x = sq. ft. Valuation of completed work $ (Labor & Materials) Desired start date / / Estimated completion date / / See next page ******************************************************************************* OFFICE USE ONLY APPROVED / DISAPPROVED By: Date / / Official Permit # Date Paid / / Check # Basement Finish & Remodel Bldg Permit App revised 01/10/12

City Of Wyoming - Department Of Building Safety Application For Building Permit Continued Site address address city State zip Please identify all General Contractors and Sub-Contractors to be performing work on this permit: General: name phone # license # Plumbing: name phone # license # Electrical: name phone # license # Carpentry: name phone # Sheetrock: name phone # Heating: name phone # Insulation: name phone # The undersigned agrees to do all work in conformance with The Minnesota State Building Code and City of Wyoming Ordinances, and herewith declares that all facts and representations on this application are true and correct. THE UNDERSIGNED AGREES TO NOTIFY THE INSPECTIONS DEPT. WHEN READY FOR INSPECTIONS. Signature of Applicant Date / / ******************************************************************************* OFFICE USE ONLY Permit # Basement Finish & Remodel Bldg Permit App 01/10/12

Date PLEASE PRINT *************************************************************************************** OFFICE USE ONLY Required Inspections: Rough-In Final APPROVED / DISAPPROVED By: Date / / Official Permit # Date Paid / / Check # Plumbing Permit Application 2008 revised 12/16/11 City Of Wyoming - Department Of Building Safety APPLICATION FOR PLUMBING PERMIT Structure Used As Owner Phone # Site Address Legal Description Lot Block Subdivision city State zip Sec Twp 33N Range 21W Zone PIN (Tax) Number _R 21. Plumbing Contractor Name Phone # Address Contact Person Job Description Estimated Cost $ Number of each item listed below: Water Closet (toilet) Dish Washer Laundry Trays Bath Tub Garbage Disposal Floor Drain Whirlpool Tub Kitchen Sink Sewer Line Urinal Drinking Fountain Water Line Bidet Catch Basins Lawn Sprinkler Lavatory (bath sink) Water Softener Standpipe Shower Sewage Ejector Hose bib Grease Interceptor Gas piping Sewage Ejector Water Heater Size (Gas or electric) Oil/Flammable Waste Separator To install gas piping you must be licensed with the City of Wyoming License # Garage Floor Drain (Cannot discharge into septic or sewer) The undersigned agrees to do all work in conformance with The Minnesota State Building Code and herewith declares that all facts and representations on this application are true and correct. THE UNDERSIGNED AGREES TO NOTIFY THE INSPECTIONS DEPT. WHEN READY FOR INSPECTIONS. _ Signature of Applicant This permit may be issued only to a licensed plumbing contractor or to an owner who occupies the single-family dwelling. MN Statute 326.40 Date

Date PLEASE PRINT City Of Wyoming - Department Of Building Safety APPLICATION FOR A HEATING, VENTILATION & AIR CONDITIONING PERMIT Structure Used As Owner Phone # Site Address Legal Description Lot Block Subdivision Sec Twp 33N Range 21W Zone PIN (Tax) Number _R 21. city State zip Heating Contractor Name Phone # Address Contact Person Job Description Estimated Cost $ Fuel Source Oil Gas (Natural or LP?) Wood/Solid Fuel Scope of work Check all that apply Furnace Hot Water Boiler Gas Piping Gas Fireplace Air Conditioner Refrigeration Gas Log Man. Wood Fireplace Ductwork Ventilation/Exhaust Log Lighter Misc. Other Equipment that will be installed: Type of equipment Manufacturer Model No. Fuel Flue Dia. Input/BTU s CFM Tons Air to Air Exchanger Heat / Energy (circle one) Recovery Ventilator Manufacturer Model No. Defrost Deduction Rated low capacity Rated high capacity % CFM CFM The installation of a solid fuel appliance or an exhaust system of 300 CFM or more will require the submittal of a ventilation worksheet. Provide the name of the electrical contractor doing the wiring: To install gas piping you must be licensed with the City of Wyoming License # GL The undersigned agrees to do all work in conformance with The Minnesota State Building Code and herewith declares that all facts and representations on this application are true and correct. THE UNDERSIGNED AGREES TO NOTIFY THE INSPECTIONS DEPARTMENT WHEN READY FOR INSPECTIONS. Signed Date: / / ********************************************************************************************* OFFICE USE ONLY ORSAT Test Required Yes No Required Inspections: Rough-In Gas Line Pressure Test Final APPROVED / DISAPPROVED By: Date / / Official Permit # Date Paid / / Check # Heating Permit Application 2008 revised 12/16/11