EX 2000/EX 2000 C/ GD 2000/GDP



Similar documents
Gas and flame detection Stack gas and dust analysis

How To Use An Irius Pid Detector

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

ALTAIR 5X Multigas Detector Bid Specification

BadgeRAE. User Manual. PGM-1010 CO Detector PGM-1020 H 2. S Detector

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Lockout Specification BW Clip Maintenance-free single gas detector

An easy and flexible way to do gas detection.

EXPLORER 4 MULTIPOINT

PortaSens ll G AS DETECTOR

Sieger Searchpoint Optima Plus

RAEGuard EC FGM-13XX

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Battery Powered Thermal Mass Flow Meters for Gases

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

600-GD & 600-GDL 600 SERIES GAS DETECTOR

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

WD-AMX Water Detection Controllers

COMBIMASS. Technical Data COMBIMASS eco-bio +

Application Requirement

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

GasAlertMax XT II H 2 O 2 LEL

7 Lighting Technology

Manual for Fire Suppression & Methane Detection System

Instructions for Safe Use

User's Guide. Pinless Moisture Meter. Model MO257

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

SMART SENSOR COLLECTION

Professional Series ATEX Portable Radios

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

FIREDEX Conventional Fire Panels

Battery Powered Thermal Mass Flow Meters for Gases

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

MiniRAE Portable VOC Monitor PGM-7600 OPERATION AND MAINTENANCE MANUAL

GST301. (Single Protection Zone) Operation Manual

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

TMS TANK MANAGEMENT SYSTEM

Chlorine Gas Detection System Operation & Maintenance

TABLE OF CONTENT

Home Security Alarm System

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

ALARMLINE ANALOGUE Linear Heat Detection System

LITHIUM BALANCE CHARGER

3DLevelScanner II TECHNICAL DATA SHEET

Handheld portable appliance testers

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Triple Waveband Infra-Red Flame Detection

2 Installation Explanation

site monitoring Kit Site Monitoring Kit User Manual we prove it.

ALTAIR Family Gas Detectors A Tough Bunch

Global Gas Detection and Monitoring Solutions

INTELLIGENT ENERGY ICHARGER & IDCHARGER

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Regards from the Team at Rheology Solutions.

Conventional Fire Detection and Extinguishant Control System Specification

Ultima X Series Gas Monitors

VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book

Engineering Specifications XNX Universal Transmitter

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM

S100. GSM House Alarm System.

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

PowerGem Pro Uninterruptible Power Supply

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Certificate of Conformity

UniOP epad33 and epad33t

How To Use A Power Supply Unit (Upu)

Hydrogen Leak Detection XRS system. The complete system for leak detection using hydrogen gas

EzFlex Combustible Gas Leak Detector Model EZ40

Saft Reliable energy for the internet of things. A wide range of energy solutions for sensing devices

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

SpO2 PULSE OXYMETER MD-300

GSM home alarm system s manual

UM-X Field display for continous level sensors

User Guide for the DS7060 Control/Communicator

Fire & Security DETECTORS

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

User s Manual AURORA 1.2K/2.2K

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

Analogue addressable devices

Digital Transformer Ratiometer DTR Model 8500

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

GSM Alarm System User Manual

Gasman Personal Gas Monitor

Stove Guard Kit User Manual

Operating Manual Remote Cost Control Monitor

IO-DIM6 6-Channel, Digital to Analogue Converters

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Measuring electric and magnetic fields

USB-500 Series Low-Cost Data Loggers and Accessories

Wahl C50 Calibrator FEATURES

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Buckeye Detection Systems Fixed Detection Systems Application Survey

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Current Monitoring Kit

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Transcription:

Gas detectors EX 2000/EX 2000 C/ GD 2000/GDP 2000 Gas Discrimination (GD 2000 / GDP 2000) Explosimeters/ Catharometers Pocket size Long battery life High reliability New design for Enhanced performance ATEX Gas detection / stack gas monitoring

Let s protect your personnel together Going down a confined space You work in industrial hazardous areas likely to contain explosive gases and vapors. Oldham have designed a new explosimeter range to suit your requirements. We are aware of the potential risks that you face and identify the type of gas to ensure a total safety package. Ones of the smallest explosimeters on the market, with the best performance, the EX 2000, EX 2000 C, the GD 2000 and GDP 2000 identify the detected gas and the GDP 2000 displays its concentration level. Even more, they can discriminate between natural gas and other explosive gases. Light, practical and high-performance, the 2000 range of explosimeters are the ideal, compact gas detectors for industry. A tremendous efficiency Smart sensor Practical and modern design The 2000 Range of explosimeters are designed to ensure a total freedom in your personal activity : ergonomic keyboard : 3 tactile buttons high Visible alarm light weight High reliability The high quality detection sensor ensures measurement accuracy. The technique offers several advantages : exceptional response time 30 battery life hours poison resistance Standards Our explosimeters are in accordance : with the European certification : - surface : EEx iad IIC T4 - mine : EEx iad I with the North American certification : - class I groups A, B, C, and D Scale 1:1 Toxic products storage room

The 2000 Range of explosimeters are designed to minimize problems. Long battery life 12 hours with rechargeable batteries (Ni-Cd or Ni-mH) 30 hours with dry cell batteries Simple charger Intelligent two position charger 12 VDC charger Pocket size Maintenance and calibration very easy, simple and safe Friendly display panel Alphanumeric LCD display Alarm levels Units and range Maintenance mode (key) Extra brightness 2 position charger CR2002 Battery voltage Visual and audio alarms Red light flashing Pulsed alarm : 1 beep every 2 seconds for the first alarm threshold Pulsed alarm : 1 beep every 1 second for the second alarm threshold Adjustable alarm thresholds Auto operation status Auto test when switching on Auto diagnosis Confidence beep Battery and sensor faults (audio and visual alarm, continuous + pictograms displayed) 3 side visible Flash Buzzer 85 db

Main characteristics EX 2000 To measure the explosive gas concentration Detects all types of explosive gases Displays 0-100% LEL Can be programmed for a selected gas EX 2000 C To measure the concentration of explosive gases Only one detection sensor Detects and displays low concentration (0-100 LEL) and high concentration (0-100 %vol) Automatic switch over of range (catalytic or catharometric) GD 2000 To discriminate between natural gas and other explosive gases Detects all types of explosive gases with discrimination Displays simple messages for the user ie : - OK for no gas detected - NATURAL GAS or FLAMMABLE GAS GDP 2000 To discriminate between natural gas and other explosive gases, and to display the gas concentration Detects all types of explosive gas with discrimination Displays simple messages for the user ie : - OK for no gas detected - Nat G for «NATURAL GAS» or FLM G for «FLAMMABLE GAS» with the gas concentration detected in % LEL Options available 1 2 3 4 5 Protective leather case Remote sampling kit Calibration kit ATEX electric pump Chargers 3 4 2 1 5 Portable gas detectors

Technical characteristics Type EX 2000 EX 2000 C Manufacturer SA Function Explosimeter Explosimeter and catharometer Detected gases Explosive gas (%LEL) Explosive gas 0-100% LEL and 0-100% v/v gas Mode Continuous Display Gas detected value displayed Gas detected, value displayed Automatic switch from the catalytic range to the catharometric range Display panel Lighting up of LCD panel on request Message displayed The gas detected value The gas detected value Out of order Sensor fault Battery fault Operating check Alarms Gas alarm Correct operation "beep" signal that the manufactory can adjust or cancell on request Instantaneous and adjustable threshold A pre-programmed instantaneous alarm threshold Over scale alarm Visual alarm A red flash alarm Pictograms for each alarm type Audio alarm Buzzer 85 db at 30 cm Power supply 3 batteries R6 1,5 V 3 batteries R6 1,5 V 3 accus Ni-mH Ni-Cd or Ni-mH Battery lifetime 22 h with accus Ni-mH 22 h with Ni-mH 30 h with batteries 30 h with dry cell batteries Recharging time 4 h (auto adjusted charger) 4 h (auto regulated charger) 16 h (simple charger) 16 h (simple charger) Protection rating IP 66 Housing Antistatic polycarbonate Weight 230 g Type of clips Anti-sliping metallic clip Working temperature -25 C to +55 C -15 C to +45 C Dimensions 144 x 55 x 30 mm Approval EEx iad IIC T4 INERIS 98 D 5022 X Surface EEx iad I INERIS 98 Y 3001 X Mine INERIS 02ATEX0060 CSA class I groups A, B, C, D Sensor characteristics Type Plug-in catalytic Plug-in catalytic-catharometric Standard range 0-100 % LEL 0-100% LEL or 0-5% CH4, 0-100% v/v 0-5 % CH4 Accuracy +/-1 % LEL or +/- 3 % +/-1% LEL or +/-3% Minimum detected 1 % LEL 1 % LEL Zero drift < 1 % of full scale per month 0,5% LEL methane per month Response time < 20 seconds at T90 Average lifetime 4 years (for normal operation) Belgium t (33) 03 21 60 81 20 f (33) 03 21 60 81 02 oldham.belgium@oldham.fr Italia t 011-3801371 f 011-3806613 info@oldham.it Česká Republica t 420 234 622 222/3 f 420 234 622 220 oldham@oldham.cz Romania t (40) 21 222 4846 f (40) 21 222 5037 oldham@fx.ro Switzerland t (41) 26 652 51 18 f (41) 26 652 51 19 info@oldham.ch United Kingdom t (44) 0 1782 562002 f (44) 0 1782 564414 sales@oldham.biz Deutschland WINTER t (49) 231 924 10 f (49) 231 924 125 info@winter-gmbh.com

GD 2000 GDP 2000 SA Explosimeter Explosimeter Natural gas, explosive gas Natural gas, explosive gas : 0-100% LEL Continuous Type of gas detected Gas type detected and value displayed OK, gas NATURAL, gas EXPLOSIVE Lighting up of LCD panel on request gas NATURAL, gas EXPLOSIVE Gas detected value Correct operation "beep" signal that the manufactory can adjust or cancell on request A 5 % LEL gas naturel threshold A 20%LEL natural gas threshold A 20% LEL threshold, butane equivalent -25 C to +55 C An early-warning alarm for natural gas A NATURAL gas alarm threshold Over scale alarm Over scale alarm A red flash alarm Pictograms for each alarm type Buzzer 85 db at 30 cm 3 batteries R6 1,5 V Ni-mH 22 h with Ni-mH 30 h with dry cell batteries 4 h (auto regulated charger) 16 h (simple charger) IP 66 Antistatic polycarbonate 230 g Anti-sliping metallic clip -25 C to +55 C 144 x 55 x 30 mm EEx iad IIC T 4 INERIS 98 D 5022 X Surface EEx iad I INERIS 98 Y 3001 X Mine INERIS 02ATEX0060 CSA class I groups A, B, C, D Precalibrated plug-in catalytic 0-100% LEL natural gas 0-100 % LEL 0-100% LEL butane (standard) 0-100% LEL other gases +/-1% LEL or +/- 3% +/-1% LEL or +/- 3% 1 % LEL 1 % LEL 0,5% LEL methane per month < 1 % of full scale per month < 20 seconds at T90 4 years (for normal operation) Your agent or retailer Plant and head office : Z.I. Est - rue Orfila B.P. 417-62 027 ARRAS Cedex FRANCE Tel. : 33 3 21 60 80 80 Fax : 33 3 21 60 80 00 Web site : http://www.oldhamgas.com 30 55 144 Explosimeters/ Catharometers This is not a contractually binding document. SA reserves the right to make any changes, without notice, to the technical characteristics of its equipement. Designed and created by Audace 33 3 21 135 600. Edition ref.: EX/GDP/EXC/GD2000GB04