TIA Releases Guidelines for Maintaining Polarity Using Array Connectors



Similar documents
The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

Upgrading Path to High Speed Fiber Optic Networks

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Fiber Systems. Best Practices for Ensuring Polarity of Array-Based Fiber Optic Channels

Data Center Design for 40/100G

Patch Cords for Data Center Applications

How To Make A Data Center More Efficient

Corning Cable Systems Optical Cabling Solutions for Brocade

Pretium EDGE HD Solutions

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Cable Assemblies. Features and Benefits

Keyed LC Connector Solution

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

Infrastructure for the next three generations

Zone Distribution in the Data Center

Data Center Fiber Cabling Topologies and Lengths. Paul Kolesar IEEE HSSG, September 2006

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

AMP NETCONNECT Data Center Cabling Solutions

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

LANscape Solutions for Xcelerated Bandwidth Applications LANscape Xcelerate and Xcelerate Plus Solutions

Plug & Play Universal Systems

Arista 40G Cabling and Transceivers: Q&A

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Loss & Continuity Testing with MPO/ MTP Connectors

Cable Assemblies. Corning Cable Systems

Cable Assemblies. Pretium EDGE Reverse Polarity Uniboots Photo LAN ST Compatible Ultra PC 12-Fiber Cable Assembly Photo LAN2784

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Corning Cable Systems Optical Cabling Solutions for Brocade

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

UniCam High-Performance Connectors, Multimode and Single-Mode

Cable Assemblies. A LANscape. Solutions Product

Corning Cable Systems CAH Connections SM Gold Program Tested and Trusted Cable Assembly Houses for High-Quality Products

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Tools for Building a Better Network

Obsolete Fiber Technology? Not in my Data Center!

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE

How To Properly Maintain A Fiber Optic Infrastructure

Data Center Topology Guide

HUBER+SUHNER AG Phil Ward

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

DATA CENTRES NETWORKS

Pretium Connector Housings

The Need for Low-Loss Multifiber Connectivity

MTP Optical Fibre Configurations

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Tapping Technology. Just the Facts about the Pretium EDGE Tap Module

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

10G and Beyond in the Data Center with OM3 Fiber

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Category 8 Cabling Standards Update

Secure/Keyed LC System Solutions Overview

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

Network Monitoring - Fibre TAP Modules

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

First Edition. Copyright Optical Connectivity - all rights reserved Rev. 2.3 (Doc. # OC )

24 fiber MPOptimate Configuration and Ordering Guide

Gigabit Passive Optical Networks

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Fiber in the Data Center

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

MPO. Fast Fibre Solution for Data Centres

Healthcare. Passive Optical LAN Solutions

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Arista and Leviton Technology in the Data Center

Copper Patch Cords. Impact On Network Performance and Reliability

Polymer Coated Fiber Cable (PCF)

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Security & Surveillance Cabling Systems

What is a Datacenter?

How To Make A Fibre Cable For A Data Centre

Simplified 40-Gbps Cabling Deployment Solutions with Cisco Nexus 9000 Series Switches

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Optimizing Infrastructure Support For Storage Area Networks

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Field-Installable Fiber Optic Connector Tool Kits A LANscape Solutions Product

Network Design. Yiannos Mylonas

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Total Solutions Verification

InstaPATCH Cu Cabling Solutions for Data Centers

40/100 Gigabit Ethernet: The Foundation of Virtualized Data Center and Campus Networks

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

PCI Express* Ethernet Networking

The ABC of Direct Attach Cables

Transcription:

Corning Cable Systems TIA Releases Guidelines for Maintaining Polarity Using Array Connectors What is new? ANSI/TIA-568-B.1-7-2006 Commercial Building Telecommunications Cabling Standard, Part 1 General Requirements, Addendum 7 Guidelines for Maintaining Polarity Using Array Connectors Standard was ANSI approved in January 2006 and should soon be available for purchase. The Standard is identified as Addendum No. 7 to TIA-568-B.1. Corning Cable Systems was an active participant in the development of this Standard. What is the purpose of the Standard? The Standard provides serial transmission or bi-directional fiber polarity guidance for systems using MTP optical connectivity. Such guidance would be applicable to the LANscape Plug & Play System Solution with MTP Connector modules. Local area network (LAN) and data center storage area network (SAN) dense wiring requirements facilitate the use of array style connectors like the MTP Connector. These scenarios often utilize pre-assembled and field-terminated MTP-to-MTP connectorized cables called trunks. Since there are array connectors on both ends of these trunks and the end equipment typically has standard duplex transceiver ports, the trunks are plugged into factory-made breakout furcations called modules that transition from the MTP Connector to a duplex connector/adapter style. TIA Polarity Standard 1of 6

What is the purpose of the Standard? (continued) Like simplex and duplex connectors and adapters, the MTP Connectors and adapters are also keyed to ensure the proper orientation is maintained when connectors are mated. With MTP Connectors, this keying establishes the orientation of one fiber array in one connector relative to the array in the mating connector, but does not ensure that duplex fiber pair polarity is maintained. The MTP Connector has 12 fibers and the Standard provides polarity guidance for serial transmission I m confused..? Data center backbones have migrated to higher-fiber-count optical ribbon cables to meet increasing system bandwidth needs as well as to provide the highest fiber density relative to cable size, maximize utilization of pathway and spaces and facilitate ease of termination. Each 12-fiber ribbon translates into six 2-fiber serial optical circuits that require polarity management that can be achieved using one of numerous methods. How many polarity methods are included in the Standard and are they mandatory? The Standard includes guidance on three sample methods identified as Method A, Method B and Method C. The Standard states in paragraph 3.1 that While many methods are available to establish polarity, this Standard outlines sample methods that may be employed. The word may implies that alternate polarity methods are available to accomplish the same result that are not discussed or included in the Standard. Thus, the Standard shows three examples and recognizes that other valid methods also exist such as the Corning Cable Systems Plug & Play Systems Universal Polarity Management. TIA Polarity Standard 2of 6

TIA Polarity: Method A What three methods are included in the Standard? A Patch Cord B Patch Cord R L R L R L R L R L R L R L R L R L R L R L R L Figure 1. Method A Drawing ZA-3026 Method A (Figure 1) uses a single module type wired in a straight through configuration and two different patch cords in an optical circuit. One patch cord is straight wired and the other with a pair-wise flip. All components in the channel are mated key-up to key-down. No guidance is included in the Standard to differentiate where the different type patch cords should be used and how it should be made so that it is easily recognizable from the regular duplex patch cord. Because polarity is addressed in the patch cords, the end-user is ultimately responsible for managing it. ZA-302 TIA Polarity Standard 3of 6

TIA Polarity: Method B Just the Technical Facts R L R L R L R L R L R L R L R L R L R L R L R L Key-up to Key-up Key-up to Key-up Figure 2. Method B Drawing ZA-3027 Method B (Figure 2) uses a single module type wired in a straight through configuration and standard patch cords on both ends. The differences is that all components in the system are mated key-up to keyup. When the link is configured in this fashion, physical position #1 goes to physical position #12 on the other end. A module on one end is inverted so logically (label-wise) position #1 goes to position #1. This method requires advance planning for module locations in order to identify the module types and location of the inverted module in the optical link. This adds complexity to the polarity management. Using an MTP Connector key-up to key-up configuration does not allow use of an angled polished (APC) single-mode connector. This method is similar to a legacy, dated and antiquated A-B module configuration. ZA-30 TIA Polarity Standard 4of 6

TIA Polarity: Method C Just the Technical Facts R L R L R L R L R L R L R L R L R L R L R L R L Figure 3. Method C Drawing ZA-3028 Method C (Figure 3) uses a pair-wise fiber flip in the trunk cable to correct for polarity. This enables the use of the same module type on both ends of the channel and standard patch cords. Because polarity is managed in the trunk, extending the links requires planning of the number of trunks in order to maintain polarity. The Standard does not include text regarding the ability to migrate to parallel optics for Method C, but parallel optic capability can easily be achieved with a special patch cord to reverse the pair-wise fiber flips in the trunk. Method C is Corning Cable Systems Plug & Play Systems classic solution, which has been the standard polarity method offering. However, Corning Cable Systems now offers the Plug & Play Universal System for substantially easier polarity management. Corning Cable Systems will continue to offer the classic polarity solution but encourages end-users to use the Plug & Play Universal System for universal polarity management. ZA-302 TIA Polarity Standard 5of 6

Universal Polarity Management What is universal polarity management? Universal polarity (Figure 4) is an exclusive Corning Cable Systems enhanced polarity management method. The method uses the same module and patch cord types at both ends with no inversion or reconfiguration needed to maintain polarity. The system is mated key-up to key-down. The method supports simple concatenation of multiple trunks without effecting polarity. The method easily accommodates all simplex/duplex connector types as well as single-mode fiber APC MTP Connectors. Similar to Methods A, B and C, Plug & Play Universal Systems polarity management easily facilitates migration to parallel optics. The wired modular system components enable fast and simple networking moves, adds and changes without polarity concerns associated with special polarity-compensating components used in Methods A, B and C. Rx Tx Rx Tx R L R L R L R L R L R L R L R L R L R L R L R L with MTP Connector with MTP Connector Figure 4. Universal Polarity Management Drawing ZA-3029 Are the different polarity methods interoperable? Each of the methods works when the rules of that method are followed. The user is cautioned, however, not to mix and mate component parts from the various methods. This will not necessarily work. The Addendum No. 7 Standard states that one method should be chosen and used throughout the network. Corning Cable Systems specifically includes identification markings on the cable trunk and modules to identify the universal polarity method. ZA-30 Please contact Doug Coleman, Manager of Technology and Standards, at 828-901-5580 if you have any questions or require additional information. Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-901-5973 International: +1-828-901-5000 www.corning.com/cablesystems. Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. Plug & Play and Pretium are trademarks of Corning Cable Systems Brands, Inc. Discovering Beyond Imagination is a trademark of Corning Incorporated. MTP is a registered trademark of USConec, Ltd. All other trademarks are the properties of their respective owners. 2006 Corning Cable Systems. All rights reserved. Printed in the USA. LAN-751-EN / September 2006 / pdf TIA Polarity Standard 6of 6