COLORADO MODEL. 35 x 65 SPECIFICATIONS



Similar documents
DENVER MODEL 30 X 30 SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Preformed Metal Roofing and Siding

2. Division 05 Structural Steel Framing for steel framework requirements

GUIDELINE SPECIFICATIONS

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

SECTION 1 GENERAL REQUIREMENTS

SECTION STANDING SEAM METAL ROOF

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION PREFORMED METAL STANDING SEAM ROOFING

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

238T Standing Seam Metal Roof System (SSMRS)

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Standing Seam Roof Systems

1.02 SYSTEM DESCRIPTION

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Chapter 3 Pre-Installation, Foundations and Piers

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

Model # 940P-V6. Page 1 of 11

SECTION GROUND WATER STORAGE TANKS

PRODUCT SPECIFICATIONS

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

SECTION STANDING SEAM METAL ROOFING

STANDARD OPEN PATIO COVER

METAL BUILDING SYSTEMS

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Mechanical Installation

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

HIGH TENSION CABLE BARRIER

PART 1 GENERAL 1.1 SECTION INCLUDES

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

The minimum reinforcement for the stem wall is the placement of:

The Keep It Simple, Steel (KISS) Standard

SECTION FIRE HYDRANTS

Residential Metal Roofing

ABSeam Panel Overview and Installation Instructions

Installation Manual for STANDING SEAM ROOFING

Commercial And Industrial Steel Buildings

OGi Architectural Metal Solutions

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

SECTION STORM DRAIN SYSTEM

COMMONLY USED RESIDENTIAL BUILDING CODES

Reproduced with the permission of the American Welding Society (AWS), Miami, Florida - 09/15/ Stud Welding

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION STORM DRAINAGE SYSTEM

Chapter 3 - Structural Design

Colorado State University. Durrell Center Roof Repair

P.A.L. S SPECIFICATIONS

Additions and Alterations

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

How to secure your property after a disaster

SECTION PRECAST CONCRETE STRUCTURES

DESIGN CLARIFICATION (DC)

Simplified Steel Stair Design for Commercial and Institutional Buildings

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Springlok Flashing System

HIGH SECURITY WELDED WIRE MESH FENCE

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION WINDOW WASHING SYSTEMS

COMMERCIAL BUILDINGS. Quality Buildings Since 1983

SECTION METAL ROOF SYSTEM

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

Hunter College school of Social Work Thesis Proposal

INSTALLATION OF A BAY WINDOW

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

TechPractices: Home Front Homes:

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

VERTICAL LOCK Table of Contents

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SECTION 22 LIGHTNING PROTECTION SYSTEM

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Page & Turnbull imagining change in historic environments through design, research, and technology

Transcription:

COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square Feet Under Roof 2275 Columns shall be 8 x8 steel tube, minimum.188 wall thickness. All beams shall be structural steel tube sized according to engineering. All bolts shall be A-325 or A-307 and hidden at all connections. Roofing shall be 24 gauge curved Corrugated steel pre-cut and pre-finished with ribs running with the curve of the roof. Trim and fascia shall be 24 gauge pre-finished to match roofing. Open or welded C channel, I beams, S or Z purlins or angle iron shall not be allowed. 11875 E. Berry Drive - Dewey, AZ 86327 Ph: (928) 775-3307 Fax: (928) 772-0858 info@classicrecreation.com www.classicrecreation.com

STANDARD SPECIFICATIONS CORRUGATED STEEL ROOFING WITH ZINC RICH PRIMER & TGIC POLYESTER POWDER COATED FRAME GENERAL: 1. All structures shall be designed and fabricated to the IBC (Latest Edition) with standard load designs of 20# per S.F. minimum live load, 100 mph wind load and the applicable zone for seismic loads. 2. All members shall be designed according to the American Institute of Steel Construction (AISC) specifications and the American Iron and Steel Institute (AISI) specifications for cold-formed members. 3. All fabrication welds shall be in strict accordance with the structural welding code of the American Welding Society (AWS) specifications. All structural welds shall be in compliance with the requirements of Pre-qualified welded joints. All welding shall conform to ASTM A-233 series E-70XX electrodes - low hydrogen. Field welding shall not be required. 4. The shade structure manufacturer shall submit structural calculations after award of bid, sealed by a registered engineer in the state in which the structure is to be erected for review and approval by the approving agency. 5. Manufacturer qualifications: All manufacturers shall have a minimum of 5 years experience in the fabrication of tubular steel shade structures. Shade structure fabrication shall be the manufacturer s primary business. Manufacturer shall have fabricated similar structures to that which is specified. FOOTINGS & COLUMNS: 1. Footings shall be structurally engineered by the structure manufacturer to meet local codes and site conditions. (Sample footing drawings shall be made available to the contractor or owner from the manufacturer). Anchor bolts for surface mounted structures shall be supplied by the owner / contractor. Concrete footing rebar shall be ASTM A-615 grade 40 #4 bars & smaller, grade 60 #5 bars & larger. Concrete shall be 5 sack mix Portland cement. Maximum slump shall not exceed 4. Compressive strength: 2500 psi @ 28 days. FRAME MEMBERS AND COMPRESSION RING: 1. All frame members shall be one piece structural steel tube with a minimum.120 (1/8 ) wall thickness, sized according to engineering. All frame members shall be bolted together with bolts totally concealed. Compression rings shall be fabricated from structural steel tube or flat plate steel and shall have all connections concealed from view. All tubing for frame members shall be ASTM 500 grade B. Beam end plates shall be ASTM A36 fy=36,000 psi UNO. Bolts shall be A 325 s unless noted otherwise. I beams, Angle iron, C, Z or S purlins or beams, open or closed, shall not be allowed.

ROOFING AND TRIM: 1. All roofing shall be 24 gauge Zincalume / Galvalume coated corrugated steel panels. Panels shall be 34 2/3 wide with 7/8 high ribs @ 2 2/3 o.c. All roofing shall be prefinished with PVF2 (Polyvinylidene Fluoride) Kynar 500. All roof panels shall be pre-cut with ribs running with the slope of the roof. Screws shall match roof color. PAINT: 1. All frame members shall be media blasted to a white finish removing all rust, scale, oil and grease. Powder coat all frame members with zinc rich primer, (min. 2.5-3 mil) and TGIC polyester, (min. 2.5-3 mil for a total minimum thickness of 5-6 mils. Finish shall be a smooth uniform surface with no pits, runs or sags. ERECTION: 1. Manufacturer shall supply complete layout and detail plans with installation instructions for the structure. The structure shall be erected in a work-man-like manner with framing, roofing and trim installed according to the manufacturers installation instructions. Care shall be taken to avoid damaging the structure during installation. WARRANTEE: 1. Manufacturer shall warranty the structure to be free from defects in material and workman-ship for a period of (5) five years from date of acceptance by owner. Warranty does not include damage from theft, fire, vandalism or acts of God. Manufacturer shall repair or replace structure components of like kind at his option, to match existing material and workmanship. NOTE: Engineering specifications take precedence over drawings if differences occur.