Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options



Similar documents
Flue Installation. High Efficiency Condensing Boilers

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Combi 30 HE. Installation & Service Instructions

ferroli Boiler Replacement Optimax HE- Modena HE

Alpha CD13R,18R and 24R

Installation Instructions

Spare Parts List M96A.24SM/B M96A.28SM/B

Alpha InTec 12S, 18S, 28S

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

ASX7-4-IOM-7 J

Alpha InTec 30GS and 40GS

Installation and Servicing Instructions

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Response: The combi boiler. Response: The fit anywhere combi

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler

HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE

Cooktop Low-Profile Ventilation Hoods

GREENSTAR 60/100 HORIZONTAL FLUE

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

INSTALLATION OF A BAY WINDOW

Betacom. 24c G.C. No c G.C. No Installation and Servicing. High Efficiency Condensing Combination Boilers

QUANTEC COMBI ErP. High Efficiency Combination Boiler. sustainable solutions under one roof INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

Response: The combi boiler. Response: The fit anywhere combi

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

MVX-Series Diesel Engine Air Shut Down Valves

Installation Instructions For Slider Casement Air Conditioners

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

VW Caddy W INSTALLATION INSTRUCTIONS

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

Original Assembly Guide

UBBINK SOLAR IN-ROOF SYSTEM

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Mikrofill Ethos Condensing combination boiler

Triac Printed Circuit Board Replacement

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

1. Description. 2. List of Accessories included A B C F G H

REMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION SYSTEMS FOR VOLVO L-4 CHASSIS

Aludesign K A T A L O G

Solar Collector Series. Product List

TFSR & TFSK Roof Fans

MANUAL INSTALLATION & SERVICING. Classic Slimline FF Installers guide to central heating boilers. Wall hung, fanned flue, gas fired boiler

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Syphonic Roof Drainage

Rooflight INSTALLATION INSTRUCTIONS

Installation Instructions

24CDi/28CDi/35CDi II RSF

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Flamco Stainless steel mountings

INFRARED QUARTZ WALL HEATER

INSTALLATION INSTRUCTIONS BL-8704

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

High Efficiency Boiler Range Technical Guide

Installation & Servicing Instructions

plumbing products guide

Mini USB and USB 2.0-IP67 Connector System

Drive shaft, servicing

Standard Bills of Materials Commonly Ordered Models Only

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

INSTALLATION INSTRUCTIONS MK-8704

Installer s Guide 18-AH39D1-13

INSTANTANEOUS GAS FIRED

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

BASIC PLUMBING. 2 - Preparation. The simple skills required for basic plumbing are explained in this project.

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Toroidal Conductivity Sensor

INSTALLATION INSTRUCTIONS

Installation Instructions

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

Instructions for Use Installation and Servicing. To be left with the user

only Energy saving boiler technology at its best

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

Builder Specifications for Solar Ready Homes

installation and servicing

High efficiency, cast-iron gas boiler

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

Getting the best from your urn

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

MGB Chrome Bumper Conversion

Transcription:

Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options

B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since 1975. From its present manufacturing base in Halstead, Essex, the Company now produces a wide range of boiler products distributed the length and breadth of Britain and Ireland. Halstead Boilers are totally committed to the design and manufacture of high performance domestic central heating appliances and supports its product with a dedicated Technical Services and Training Centre in Leamington Spa, Warwickshire. A nationally appointed network of Service Agents ensures that after installation queries can be dealt with by a fully trained, locally based service engineer. Ace Finest Finest Gold Best 30/40/50/60 Best 80 Halstead appliances and flueing accessories are available from independent merchants and regional merchant groups throughout Britain and Ireland. Halstead Boilers are also fully committed to providing a spares service for both existing and discontinued appliances. A full range of Halstead boiler spares are available from our nationally appointed network of dedicated Spares stockists. For full information on our products, spares and services visit our website at www.halsteadboilers.co.uk F L U E O P T I O N S

This Flue Application Guide is intended to complement the Installation and Service Instructions supplied with each Halstead appliance. The guide provides the installer with full and detailed information on the various flueing options commonly used with our range of wall mounted appliances. It also gives information on our range of flue accessories available from Halstead boiler stockists nationwide. If in doubt, please do not hesitate to call our Service Helpline: 01926 834834. RULE ONE: The Ace, Finest, Finest Gold, Best 30/40/50/60 and Best 80 each have their own maximum flue lengths both horizontally and vertically. Refer to the relevant sections shown on the following pages to check the suitability of each flue system for your installation needs. You may need to purchase flue accessories. Refer to the flue system components technical specifications shown in each section. RULE TWO: The maximum allowable flue length for each appliance is reduced when a flue bend is included (ie an extension elbow). RULE FIVE: The flue system must use either a flanged elbow or a flanged vertical turret socket at the exit of the appliance. RULE SIX: All flue joints must be secured in accordance with the Installation Instructions supplied with each appliance. RULE SEVEN: Twin pipe systems shown in Section 12 allow longer flue lengths to be achieved. However the standard concentric flue supplied with the appliance must be discarded. RULE THREE: The standard flue must terminate horizontally as shown in the Installation Instructions. A slight fall away from the appliance will reduce the possibility of any ingress of rain water. RULE FOUR: If the flue is to terminate vertically the Vertical Flue Terminal must be used. TELESCOPIC Supplied as standard with the appliance. EXTENDED HORIZONTAL RAISED HORIZONTAL VERTICAL TWIN PIPE SYSTEMS ACCESSORIES 4 6 8 10 12 14

T elescopic The Ace, Finest, Finest Gold and Best appliances are supplied complete with a 90 flanged elbow and telescopic flue duct. Designed to suit the vast majority of installations, the elbow can be fitted to the appliance to point in any direction (45 intervals) whilst the flue duct is telescopic from 545mm up to a maximum length of 820mm measured from the centre of the flue outlet. Fibre seal and O ring are supplied to seal between the appliance and the flanged elbow. Wall seals are also included to provide a neat finish on both inner and outer walls. 820mm MAX. When the standard telescopic kit is used with the Finest and Finest Gold combination appliances and when no other flue components are used, a flue restrictor, supplied with the appliance, must be inserted. If any other flue components or extensions are used, this restrictor must be discarded. With the Ace combination boiler in right hand or left hand horizontal flue applications, and where the standard telescopic flue is used, a Flue Air Guide - supplied with the appliance, must be inserted as detailed in Installation Instructions. In rear, extended horizontal and vertical flue applications, this should be discarded. 820mm MAX. F L U E With Finest, Finest Gold and Best boilers only, the standard telescopic flue ki is also suitable for high rise SE-DUCT applications where the flue duct feeds to a common flueing chamber (SE-DUCT) in the centre of the building. Entry of the telescopic flue should be as close to the centre of the SE-DUCT as possible. The flue must not be positioned in the corner of the SE-DUCT. The external wall sealing ring is not used and the end of the air duct must be fitted flush with the inside of the SE-DUCT chamber. O P T I O N S 188mm 820mm MAX. 200mm 820mm MAX. ACE 200mm 820mm MAX 145mm GOLD 145mm BEST db 30/40/50/60 BEST db 80 4 TELESCOPIC

95mm SE-DUCT APPLICATION TELESCOPIC FLUE SYSTEM COMPONENTS & GOLD FLUE RESTRICTOR 251023 This flue restrictor is designed specifically for the Telescopic Flue. And must only be used when no additional components are fitted. ACE FLUE AIR GUIDE 190059 Supplied with the appliance - to be used in RH/LH telescopic flue applications only. 60mm DIA. O RING SEAL 150mm 128mm DIA. FIBRE SEAL 352559 90 FLANGED ELBOW 130596 Seal required. Resistive length: 767mm Adjustable 470-745mm MAXIMUM 425mm 320mm MAXIMUM USEABLE TELESCOPIC FLUE ASSEMBLY 130605 INTERNAL & EXTERNAL WALL SEALS 352552 (White Inner) 352016 (Grey Outer) 100mm DIA. 160mm DIA. TELESCOPIC 5

Extended Horizontal If the appliance cannot be sited close to an adjacent outside wall, it is possible to extend the telescopic flue with extension ducts and 90 or 45 elbows. Maximum allowable flue length varies between appliances and must be followed to ensure safe and correct appliance operation as illustrated below. In calculating the flue length the following must be considered: Each duct extension measures 817mm with a 767mm useable length (i.e. 50mm seal) A 90 extension elbow has an equivalent length of 767mm - this is known as the resistive length A 45 extension elbow has a resistive length of 3 ACE 3000mm MAXIMUM FLUE LENGTH - requires 3 extensions Outer Section - Telescopic Flue (supplied with boiler) In extending the flue ducting it is also possible to raise or lower the horizontal ducting. Ducting should not be lowered more than 500mm. Fibre seal and O ring are supplied to seal between the appliance and the flanged elbow. Wall seals are also included to provide a neat finish on both inner and outer walls. Flue Extension Ducts F L U E O P 4655mm MAXIMUM FLUE LENGTH - requires 5 extensions T I O N S Inner Section - Telescopic Flue (supplied with boiler) 2354mm MAXIMUM FLUE LENGTH - requires 2 extensions 3812mm MAXIMUM FLUE LENGTH - requ 3045mm MAXIMUM F GOLD BEST db 30/40/50/60 BEST db 80 6 EXTENDED HORIZONTAL

95mm EXTENDED HORIZONTAL FLUE SYSTEM COMPONENTS 128mm FIBRE SEAL 352559 60mm O RING SEAL 90 EXTENSION ELBOW 954011 No Seal required. Resistive length: 767mm 4 extensions 90 FLANGED ELBOW 130596 Seal required. 150mm 767mm 45 45 EXTENSION ELBOW 954010 No Seal required. Resistive length: 3 LENGTH - requires 3 extensions FLUE EXTENSION DUCT 955065. Useable length: 767mm PLEASE NOTE: When using a Flue Extension Duct with an Extension Elbow, the flared flange will need to be removed using a hacksaw on both inner and outer ducts. Adjustable 470-745mm MAXIMUM 425mm 320mm MAXIMUM USEABLE TELESCOPIC FLUE ASSEMBLY 130605 100mm DIA. 500mm MAX. 160mm DIA. INTERNAL & EXTERNAL WALL SEALS 352552 (White Inner) 352016 (Grey Outer) FLUE DUCT SUPPORT BRACKET 840517 100mm dia, white EXTENDED HORIZONTAL 7

Raised Horizontal A+B=3000mm Max Extension Elbow Flue Extension If the desired outlet point is higher than the appliance, it is possible to raise the flue directly from the appliance and then to use the telescopic flue duct. If necessary this may be further extended horizontally with extension ducts, 90 or 45 elbows. In this application the 90 flanged elbow supplied with the appliance should be discarded and a vertical turret socket used to connect to the appliance. A Outer Section of Telescopic Flue (supplied with boiler) Vertical Turret Socket ACE A+B=4655mm Max A B Flue Extension Maximum raised horizontal flue lengths vary between appliance types and must be followed to ensure safe and correct appliance operation as illustrated below. In calculating the flue length the following must be considered: Each duct has a useable length of 767mm A 90 extension elbow has a resistive length of 767mm A+B=2354mm Max A Inner Section - Telescopic Flue (supplied with boiler) B A B F L A+B=3812mm Max U E A 45 extension elbow has a resistive length of 3 In extending the flue ducting it is also possible to raise or lower the horizontal ducting. Ducting should not be lowered more than 500mm. Fibre seal and O ring are supplied to seal between the appliance and the flanged elbow. Wall seals are also included to provide a neat finish on both inner and outer walls. O P T I O B A+B=3045mm Max N S A GOLD BEST db 30/40/50/60 HORIZONTAL 8RAISED BEST db 80

30mm 50mm RAISED HORIZONTAL FLUE SYSTEM COMPONENTS 128mm FIBRE SEAL 352559 60mm O RING SEAL 90 EXTENSION ELBOW 954011 No Seal required. Resistive length: 767mm 100mm DIA. VERTICAL FLUE TURRET SOCKET 130606 Supplied as part of Vertical Flue Kit. Useable length 30mm 45 45 EXTENSION ELBOW 954010 No Seal required. Resistive length: 3 767mm FLUE EXTENSION DUCT 955065. Useable length: 767mm PLEASE NOTE: When using a Flue Extension Duct with an Extension Elbow, the flared flange will need to be removed using a hacksaw on both inner and outer ducts. Adjustable 470-745mm MAXIMUM 425mm 320mm MAXIMUM USEABLE TELESCOPIC FLUE ASSEMBLY 130605 Flue Options Book PLEASE NOTE When using a Flue Extension Duct with an Extension Elbow, the flared flange will need to be removed using a hacksaw on both inner and outer ducts. INTERNAL & EXTERNAL WALL SEALS 352552 (White Inner) 352016 (Grey Outer) RAISED HORIZONTAL 100mm DIA. 160mm DIA. FLUE DUCT SUPPORT BRACKET 840517 100mm dia, white 9

V ertical Vertical Turret Socket Vertical Flue Terminal (Telescopic) Pitched Roof Flashing Reducer Sockets Flue Extensions Outer Section of Telescopic Flue (Supplied with boiler) ACE 4618mm MAXIMUM FLUE LENGTH - requires 4 Extensions 6152mm MAXIMUM FLUE LENGTH - requires 6 Extensions & PROPANE Vertical flueing allows significant extensions to flue ducting but must be terminated through a flat or pitched roof using the approved vertical flue terminal. Maximum flue lengths vary between appliance types and must be followed to ensure safe and correct appliance operation as illustrated below. In calculating the flue length the following must be considered. 3851mm MAXIMUM FLUE LENGTH - requires 3 Extensions F L U E 4400mm MAXIMUM FLUE LENGTH - requires 4 Extensions If a 90 flanged elbow is used directly from the appliance instead of a vertical flue turret this elbow has an equivalent length of 750mm. Each duct extension has a useable length of 767mm. A 90 extension elbow has a resistive length of 767mm. A 45 extension elbow has resistive length of 3. Fibre seal and O ring are supplied to seal between the appliance and the flanged turret. O P T I O 3633mm MAXIMUM FLUE LENGTH - requires 3 Extensions N S GOLD 10 VERTICAL BEST db 30/40/50/60 BEST db 80

95mm 110mm 70mm 90mm 30mm 180mm 50mm NOTE When a vertical flue is installed, the outer section of the standard telescopic flue (supplied with the appliance) must be used in conjunction with a Vertical Turret Socket, directly from the boiler. The inner telescopic section should be discarded. The Vertical Flue Roof Terminal then fits onto this section using a Reducer Socket. Extension Ducts may be inserted between. VERTICAL FLUE SYSTEM COMPONENTS 390mm DIA. FLAT ROOF FLASHING 840512 40mm 40mm 767mm FLUE EXTENSION DUCT 955065 Useable length: 767mm Flue Options Book 152mm PITCHED ROOF FLASHING Supplied as part of the 118mm DIA. Vertical Flue Kit. 80mm DIA. 60mm DIA. 100mm DIA. REDUCER SOCKETS Supplied as part of the Vertical Flue Kit. Useable length 70mm PLEASE NOTE When using a Flue Extension Duct with an Extension Elbow, the flared flange will need to be removed using a hacksaw on both inner and outer ducts. 128mm DIA. FIBRE SEAL 352559 Supplied with the appliance. 90 FLANGED ELBOW 130596 Supplied with the appliance. Seal required. Resistive length: 750mm 45 45 EXTENSION ELBOW 954010 No Seal required. Resistive length: 3 60mm DIA. O RING SEAL Supplied with the appliance 450mm SQUARE 118mm DIA. 80mm DIA. 100mm DIA. 310mm 810-1060mm Max VERTICAL FLUE ROOF TERMINAL (with Telescopic Outer) 840506 Note: Inner duct may require cutting VERTICAL FLUE KIT: 988378 Comprising Part No s 840506 Vertical Flue Terminal. Pitched Roof Flashing. Reducer Sockets. 130606 Vertical Flue Turret Socket. 90 EXTENSION ELBOW 954011 No Seal required. Resistive length: 767mm 150mm FLUE DUCT SUPPORT BRACKET 840517 100mm dia, white VERTICAL FLUE TURRET SOCKET 130606 Supplied as part of Vertical Flue Kit. Useable length 11 30mm VERTICAL

T win-pipe Systems In special applications where very long runs of flue ducting are desired, it is possible to use a twin-pipe system. The Best and Finest appliance ranges may use a twin-pipe system in either horizontal or vertical form but on certain output models only. The Ace and Finest Gold combination boilers are not tested for use with a twin-pipe system. Maximum flue lengths vary between appliance types and must be followed to ensure safe and correct operation as illustrated below. In calculating the flue length the following must be considered. If a 90 elbow is used either directly from the appliance or in-line, this has an equivalent length of 1500mm. A 45 extension elbow has an equivalent length of 800mm. Each standard duct extension measures 1000mm with a 950mm useable length (i.e. 50mm seal). 12 TWIN PIPE SYSTEMS 840522 352611 840508 840507 850511 352559 PROPANE BEST db 30/40/50 BEST db 80 180mm 840506 840509 352611 840507 (See Table) A vertical system terminates using the standard vertical flue kit (concentric pipes as used on standard flue systems). A horizontal system terminates with a special Twin-Pipe horizontal terminal kit. Fibre seal and O ring are supplied to seal between the appliance and the Flue Flanged T Adaptor or Twin-Pipe Socket Adaptor. TWIN-PIPE SYSTEM MAXIMUM LENGTHS: ACE PROPANE BEST db 30/40/50 BEST db 80 F L Vertical U E NOT AVAILABLE 9m 14m GOLD NOT AVAILABLE BEST 30 18m 20m BEST 40 18m 20m BEST 50 18m 20m BEST 60 NOT AVAILABLE BEST 80 18m 20m 840507 840513 352559 O P Horizontal T I O 120mm N S CONDENSATE TRAP For Twin-Pipe System lengths in excess of 7 metres provision must be made for a Condensation Trap within the flue outlet (hot) pipe. Both pipes should be insulated within loft space. Any application exceeding 7 metres, must have flue outlet (hot) pipe insulated. The Trap should be fitted at a maximum of 3 metres from the top of the appliance. A 1 1 /2º fall in pipework is necessary in the direction of the boiler and along the entire flue outlet pipe length. PROPANE BEST db 30/40/50 BEST db 80 (See Table) (See Table Dimensions - Less Elbow Resistive Length)

90mm 180mm TWIN-PIPE FLUE SYSTEM COMPONENTS 128mm DIA. FIBRE SEAL 352559 To seal flue adaptors to top of appliance. 60mm DIA. TWIN PIPE O RING SEAL 352576 Supplied with the appliance. 81mm INTERNAL 50mm 165mm FLANGED T ADAPTOR FOR VERTICAL FLUEING 840511 352616 840508 840514 TWIN PIPE SOCKET ADAPTOR FOR HORIZONTAL FLUEING 840513 for Finest/Finest Gold 750875 for Best (includes rubber mounting gasket) Elbows not supplied with kit 121mm 50mm INTERNAL TWIN PIPE M&F 90 SWEPT ELBOW 840507 Resistive length: 1500mm 80mm 124mm 50mm 82mmDIA. 168mm 80mmDIA. EXTERNAL 118mm INTERNAL DIA. 195mm 170mm 290mm 338mm ASSEMBLED DIMENSIONS 260mm STANDARD EXTENSION DUCT 840508 Resistive length: 950mm For every length of extension a clamping bracket is recommended. 120mm 50mm 950mm TWIN PIPE HORIZONTAL TERMINAL KIT 840514 80mm DIA. TWIN PIPE FLUE SEAL-80mm DIA. 352611 Supplied with Elbows and Extensions. TWIN PIPE HORIZONTAL TERMINAL GUARD 840515 VERTICAL FLUE ROOF TERMINAL (WITH TELESCOPIC OUTER) 840506 Note: Inner Duct may require cutting 80mm DIA. TWIN PIPE T ADAPTOR FOR VERTICAL FLUEING 840509 45 38mm 38mm 80mm DIA. EXTERNAL 118mm DIA. 80mm DIA. 310mm 810-1060mm Max 200mm 50mm CONDENSATE KIT 840522 Supplied with rubber hose condensate trap and collecting duct. 82mm DIA. EXTERNAL TWIN PIPE M&F 45 ELBOW 840510 Resistive length: 800mm FLUE DUCT SUPPORT BRACKET 840516 80mm dia, white VERTICAL FLUE KIT: 988378 Comprising of Part No s 840506 Vertical Flue Terminal. Pitched Roof Flashing. 130606 Vertical Flue TurretSocket. (Must be discarded) Reducer Sockets. (Must be discarded) 13 TWIN PIPE SYSTEM

Accessories LARGE FLUE SEAL Extra large wall sealing ring, (grey rubber), 300mm diameter. Used with standard flue terminals to seal enlarged holes. 352020 COMBI CUP Flow measuring cup suitable for use with combi-type appliances and instantaneous water heaters. Enables domestic hot water flow rates to be set or checked quickly and simply with an acceptable level of accuracy. 954001 SERVICE MATE Appliance service kit containing a range of fibre washers, O rings, screws, metal washers, spire clips, blind rivets, and cock washers. 951528 14 ACCESSORIES

10/16 CONVERSION KIT This kit is designed for installations where the flue opening left in the wall after removal of the old appliance is too large to be effectively sealed by the standard flue kit supplied with the new Halstead appliance. It can be installed without access from outside and is therefore ideally suited for high rise applications. 955062 LARGE DIAMETER EXTERIOR SEAL SPRING TO CENTRALISE FLUE OUTLET SPONGE SEAL INNER SEAL (Supplied with appliance) INTERIOR WALL PLATE / GOLD MBC FIXING JIG The Multifunctional Boiler Chassis is normally supplied complete with the Finest & Finest Gold, but is also available separatly. It serves both as a wall template to mark the position of fixing holes and a mounting bracket to support Finest & Finest Gold appliances. It provides all water service connections so that the system pipework can be completed and commissioned prior to fitting the appliance. An essential feature where site security cannot be guaranteed during initial installation. 988362 BEST SEALED SYSTEM POD The Best system pod is an add-on kit for use with the Best30/40/50/60 & 80 appliances only. It enables the Best to be used with pressurised unvented systems and is designed to fit directly below the appliance itself. The Pod is supplied with all pipework and wiring to connect the units together. 955052 (Best 30/40/50/60) 955061 (Best 80) 15 ACCESSORIES

Halstead Boilers Limited, 20/22 First Avenue, Bluebridge Industrial Estate, Halstead, Essex CO9 2EX. Tel: 01787 272800. Sales Direct Line: 01787 475557. Fax: 01787 474588. Service Helpline: 01926 834834. e-mail: sales@halsteadboilers.co.uk or service@halsteadboilers.co.uk Website: www.halsteadboilers.co.uk Flue Options Flue Options Flue Options Flue Options Halstead Boilers are continuously improving its products and may therefore change specifications without prior notice. The statutory rights of the consumer are not affected. 01/0