AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
|
|
|
- Margaret Norris
- 10 years ago
- Views:
Transcription
1 AquaNova Water heater Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.
2 Contents Design principles & operating sequence Page 1.1 Principle components Mode of operation Safety devices 2 Technical data Page 2.1 Performance Gas pressure Dimensions Clearances Connections Electrical Flue details 3 General requirements Page 3.1 Related documents Location of appliance Gas supply Flue system Air supply Water pipe work Electrical supply Timber framed buildings 5 Installation Page 4.1 Delivery Contents Unpacking Preparation for mounting the appliance Fitting the flue Connecting the gas & water Electrical connections 10 Commissioning Page 5.1 Gas supply installation Water pipe work Pre-operation checks Initial lighting Checking the burner pressure Setting the outlet temperature Final checks Instructing the user 11 Servicing Page 6.1 General Routine annual servicing Replacement of components Component removal procedure NTC thermistors removal High limit thermostat removal Flow switch removal Gas valve removal Burner, injectors and spark/sense electrode removal Flue fan removal Heat exchanger removal Air pressure switch removal 14 Checks, adjustments, and fault finding Page 7.1 Checking appliance operation Appliance mode of operation Checking/adjusting burner pressure External faults Electrical checks Fault finding Fault codes 16 Wiring diagrams Page 8.1 External wiring 21 Exploded diagrams Page 9.1 Table Table 2 24 L.P.G. instructions Page 10.1 Technical data Related documents Gas supply Gas supply installation Checking/Adjusting the burner pressure 25
3 INTRODUCTION The Vokera AquaNova is an instantaneous water heater, which - by design - incorporates electronic ignition, NTC temperature control, continuous gas modulation, and status/fault indicators. It is produced as a room sealed, category II2H3+ appliance, suitable for wall mounting applications only. It is provided with a fan powered flue outlet with an annular co-axial combustion air intake that can be rotated horizontally through 360 degrees for various horizontal or vertical applications. The AquaNova can also be used with the Vokera twin flue system. General layout 1 Gas valve 2 High limit thermostat 3 Electrode 4 NTC sensor 5 Pressure differential switch 6 Silicone pressure tube (+) 7 Silicone pressure tube (-) 8 Fan assembly 9 Heat exchanger 10 Main burner 11 Flow switch Fig. 1 1
4 SECTION 1 DESIGN PRINCIPLE AND OPERATING SEQUENCE 1.1 PRINCIPLE COMPONENTS A fully integrated electronic control board featuring electronic temperature control, selfdiagnostic fault indicator, continuous gas modulation. Electronic ignition with flame supervision. Fan. Differential air pressure switch. Two-stage gas valve. 1.2 MODE OF OPERATION When there is a request for hot water via a hot water outlet or tap, the water flow switch senses water movement thereby energising the fan, the fan proves the differential air pressure switch which in-turn allows an ignition sequence to begin. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry increases the gas rate to maximum or modulates to suit the set requirement. When the appliance reaches the desired temperature the burner will modulate to maintain the desired temperature. Should the temperature continue to increase, the burner will shut off when the maximum operating temperature is attained. When the request for hot water has been satisfied the appliance fan may continue to operate to dissipate any residual heat within the appliance. 1.3 SAFETY DEVICES When the appliance is in use, safe operation is ensured by: a high limit thermostat that over-rides the temperature control circuit to prevent or interrupt the operation of the burner; a differential air pressure switch that checks the operation of the fan and flue thereby allowing safe operation of the burner; a flame supervision device that will shut off the gas supply to the burner if there is no flame sensed within 7 seconds. Air pressure switch NTC sensor Fan assembly Heat exchanger Burner High limit thermostat Flow regulator Gas Flow switch Fig. 2 outlet cold water inlet cold water 2
5 SECTION 2 TECHNICAL DATA 2.1 Performance Heat input 32,0 kw Heat output (max) 28,8 kw Heat output (min) 10,0 kw Minimum working pressure 0,15 kw Maximum working pressure 10,0 bar Minimum flow rate 2 litres per minute Hot water - 35 C temperature rise 11,8 litres per minute 2.2 Gas pressure Inlet pressure (G20) 20,0 mbar Maximum burner pressure 12,0 mbar Minimum burner pressure 1,5 mbar Gas rate 3,5 m 3 /h Injector size 15 x 1,30mm 2.3 Dimensions Height 640 mm Width 400 mm Depth 246 mm Weight 20 kg 2.4 Clearances Top 150 mm from casing or 25 mm above flue elbow (whichever is applicable) Bottom 150 mm Sides 50 mm Front 600 mm 2.5 Connections Cold water inlet 15 mm (compression) Hot water outlet 15 mm (compression) Gas 15 mm copper 2.6 Electrical Voltage 230V/~ 50hz Power consumption 85 W Internal fuse 2 AF External fuse 3 A 2.7 Flue details Maximum horizontal flue length (concentric) 2,4 metres Minimum horizontal flue length (concentric) 0,4 metres Maximum vertical flue length (concentric) 3,6 metres Minimum vertical flue length (concentric) 1,0 metres Maximum twin flue length (horizontal or vertical) 5m/5m + terminal N New minimum distance Fig. 3 Terminal position for fan assisted boiler (minimum distance) mm A - Directly above or below an open window 300 or other opening (e.g. air brick) B - Below gutters, soil pipes or drain pipes 25 C - Below eaves 25 D - Below balconies or car port roof 25 E - From vertical drain pipes and soil pipes 75 F - From internal or external corners 25 G - Above ground or below balcony level 300 H - From a surface facing a terminal 600 I - From a terminal facing a terminal 1200 J - From an opening in the car port (e.g. door window) into dwelling K - Vertically from a terminal on the same wall 1500 L - Horizontally from a terminal on the same wall 300 M - Horizontally from a vertical terminal to a wall 300 N - Horizontally from an opening, airbrick, openable window, etc. 300 TE: The flue must be terminated in a place not likely to cause a nuisance. 3
6 SECTION 3 GENERAL REQUIREMENTS BS 5440 PART 1 FLUES BS 5440 PART 2 FLUES AND VENTILATION BS 5546 INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES BS 6891 LOW PRESSURE INSTALLATION PIPES BS 6700 DESIGN, INSTALLATION, TESTING AND MAINTAINENCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE This appliance must be installed by a competent person in accordance with the Gas Safety (Installation & Use) Regulations. 3.1 RELATED DOCUMENTS The installation of this water heater must be in accordance with the relevant requirements of the Gas Safety (Installation & Use) Regulations, the Water supply (water fittings) Regulations, the Water Byelaws Scotland, the Building Standards (Scotland) Regulation and Building Standards (Northern Ireland) Regulations. It should be in accordance also with any relevant requirements of the local authority and the relevant recommendations of the following British Standard Codes of Practice. 3.2 LOCATION OF APPLIANCE The appliance may be installed in any room or internal space, although particular attention is drawn to the requirements of the current I.E.E. wiring regulations, and in Scotland, the electrical provisions of the Building Regulations, with respect to the installation of the appliance in a room or internal space containing a bath or shower. When an appliance is installed in a room or internal space containing a bath or shower, the appliance or any control pertaining to it must not be within reach of a person using the bath or shower. The location chosen for the appliance must permit the provision of a safe and satisfactory flue and termination. The location must also permit an adequate air supply for combustion purposes and an adequate space for servicing and air circulation around the appliance. Where the installation of the appliance will be in an unusual location special procedures may be necessary, BS 6798 gives detailed guidance on this aspect. A compartment used to enclose the appliance must be designed and constructed specifically for this purpose. An existing compartment/cupboard may be utilised provided that it is modified to suit. Details of essential features of compartment/ cupboard design, including airing cupboard installations, are given in BS This appliance is not suitable for external installation. 3.3 GAS SUPPLY The gas meter as supplied by the gas supplier must be checked to ensure that it is of adequate size to deal with the maximum rated input of all the appliances that it serves. Installation pipes must be fitted in accordance with BS Pipe-work from the meter to the appliance must be of adequate size. Pipes of a smaller size than the appliance gas inlet connection must not be used. The installation must be tested for soundness in accordance with BS If the gas supply serves more than one appliance, it must be ensured that an adequate supply is maintained to each appliance when they are in use at the same time. 3.4 FLUE SYSTEM The terminal should be located where the dispersal of combustion products is not impeded and with due regard for the damage and discoloration that may occur to building products located nearby. The terminal must not be located in a place where it is likely to cause a nuisance (see fig. 3). In cold and/or humid weather, water vapour may condense on leaving the terminal; the effect of such pluming must be considered. If installed less than 2m above a pavement or platform to which people have access (including balconies or flat roofs) the terminal must be protected by a guard of durable material. The guard must be fitted centrally over the terminal. Refer to BS 5440 Part 1, when the terminal is 0,5 metres (or less) below plastic guttering or 1 metre (or less) below painted eaves. 3.5 AIR SUPPLY The following notes are intended for general guidance only. This appliance is a room sealed, fan-flued water heater, consequently it does not require a permanent air vent for combustion air supply. When installed in a cupboard or compartment, ventilation for cooling purposes is also not required. 3.6 WATER PIPE WORK Detailed recommendations are given in BS 5449 Part 1 and BS The following notes are for general guidance only PIPEWORK It is recommended that copper tubing to BS 2871 Part 1 is used in conjunction with soldered capillary joints. Where possible pipes should have a gradient to ensure air is carried naturally to an outlet and that water flows naturally to drain cocks. 4
7 Pipes should be insulated to avoid heat loss and in particular to avoid the possibility of freezing. Particular attention should be paid to pipes passing through ventilated areas such as under floors, loft space, and void areas DRAIN COCKS These must be located in accessible positions to facilitate draining of the appliance and all water pipes connected to the appliance. The drain cocks must be manufactured in accordance with BS ELECTRICAL SUPPLY The appliance is supplied for operation on 50Hz electrical supply; it must be protected with a 3-amp fuse. The method of connection to the mains electricity supply must allow for complete isolation from the supply. The preferred method is by using a double-pole switch with a contact separation of at least 3mm. The switch must only supply the appliance. Alternatively an un-switched shuttered socket with a fused 3-pin plug both complying with BS 1363 is acceptable. Fig TIMBER FRAMED BUILDINGS If the appliance is to be fitted in a timber framed building, it should be fitted in accordance with the Institute of Gas Engineers publication (IGE/ UP/7) Guide for Gas Installations in Timber Frame Buildings. SECTION 4 INSTALLATION 4.1 DELIVERY The appliance is delivered in a heavy-duty cardboard carton. Lay the carton on the floor with the writing the correct way up. 4.2 CONTENTS Contained within the carton is: the appliance; the wall mounting bracket; template; an accessories pack containing the appliance service valves and washers; the instruction pack containing the installation & servicing instructions, user instructions and a 3-amp fuse. 4.3 UNPACKING At the top of the carton pull both sides open do not use a knife unfold the rest of the carton from around the appliance, carefully remove all protective packaging from the appliance, and lay the accessories etc. to one side. 1= centre of rear flue hole using ONLY or flue 2= centre of rear flue hole for ALL OTHER FLUES ø 6 Type 2 Type ø 125 ø PREPARATION FOR MOUNTING THE APPLIANCE The appliance should be mounted on a smooth, vertical, surface, which must be capable of supporting the full weight of the appliance. Care should be exercised when determining the position of the appliance with respect to hidden obstructions such as pipes, cables, etc. When the position of the appliance has been decided using the template supplied carefully mark the position of the wall-mounting bracket (see fig. 5) and flue-hole (if applicable). 614,5 57, Fig. 5 5
8 4.4.1 IMPORTANT There are two holes on the template. The lower hole should be used with the telescopic flue kit (part n & ). The upper hole is for use with all other horizontal flue kits MAXIMUM FLUE LENGTHS Flue system Concentric Horizontal Concentric Vertical Twin flue AquaNova 2,4m 3,6m 5m/5m + terminal 4.5 FITTING THE FLUE The top flue outlet permits both horizontal and vertical flue applications to be considered, alternatively, the Vokera twin flue system can be utilised if longer flue runs are required CONCENTRIC HORIZONTAL FLUE (For concentric vertical flue, see 4.5.2). (For twin flue applications, see 4.5.3). The appliance flue outlet elbow can be rotated through 360 on its vertical axis. In addition the flue may be extended from the outlet elbow in the horizontal plane (see 4.4.2), however if the flue is to be extended or additional bends are to be fitted, the standard horizontal flue kit (part n ) must be used. A reduction must also be made to the maximum length (see table) when additional bends are used. Reduction for bends Bend Reduction in maximum flue length for each bend 45 bend 0,5 metre 90 bend 1,0 metre IMPORTANT The flue restrictor ring must be inserted into the appliance flue outlet if the total flue length is less than 1.0m FITTING THE TELESCOPIC FLUE KIT ( & ) Carefully measure the distance from the centre of the appliance flue outlet to the face of the outside wall (dimension X see fig. 6). Add 50mm to dimension X to give the overall flue length (dimension Y). Using the complete telescopic flue assembly adjust the length to suit dimension Y. Once the telescopic flue terminal has been adjusted to the correct length, secure the flue assembly with the screw supplied. Insert the flue assembly into the previously drilled flue hole and locate the flue bend over the appliance flue outlet. Push the flue bend down over the appliance flue outlet and ensure the correct seal is made. Pull the flue assembly towards and over the flue bend - using a twisting action - ensuring the correct seal is made. Check that the terminal protrudes past the finished outside wall by the correct length (115mm). TE You must ensure that the entire flue system is properly supported and connected. Seal the flue assembly to the wall using cement or a suitable alternative that will provide satisfactory weatherproofing. The interior and exterior trim can now be fitted. Y X 115 mm Horizontal flue terminals and accessories Part No. Description Min-Max length Standard telescopic flue Extended telescopic flue Horizontal flue kit for use with add. bends & extensions 750mm extension 1500mm extension 45 bend (pair) 90 bend Wall bracket (5) 380mm-600mm (dimension X) 600mm-920mm (dimension X) 833mm (dimension X) 750mm 1500mm Using the template provided, mark and drill a 115mm hole for the passage of the flue pipe. The hole should have a 1 drop from the boiler to outside, to eliminate the possibility of rainwater entering the appliance via the flue. The fixing holes for the wall-mounting bracket should now be drilled and plugged, an appropriate type and quantity of fixing should be used to ensure that the bracket is mounted securely. Once the bracket has been secured to the wall, mount the appliance onto the bracket. Fig. 6 X + 50 mm = Y FITTING THE STANDARD ( ) HORIZONTAL FLUE KIT (see 4.4.1) Carefully measure the distance from the centre of the appliance flue outlet to the face of the outside wall (dimension X see fig. 7). Ensure the inner (60mm) pipe is fully inserted into the outer (100mm) pipe (when the inner pipe is fully inserted, it stands proud of the outer pipe by 7,5mm). Add 32mm to dimension X to give the overall flue length (dimension Y). The standard horizontal flue kit (part no ) is suitable for a distance (dimension Y) of up to 865mm. TE Dimension Y is measured from the end of the terminal to the end of the outer (100mm) pipe. The internal trim should be fitted to the flue pipe before connection of the 90 bend. 6
9 If the horizontal flue kit ( ) requires to be cut to the correct size (dimension Y), you must ensure that the inner (60mm) pipe stands proud of the outer (100mm) pipe by 7,5 mm (see fig. 8). Ensure any burrs are filed or removed and that any seals are located properly before assembly. Hold the inner (60mm) pipe of the terminal assembly and connect to the push-fit end of the 90 bend (supplied) using a twisting action. Insert the assembled flue into the previously drilled hole. Using the clips & screws supplied, connect the flue assembly to the boiler, ensuring that the terminal protrudes past the finished outside wall by the correct length (135mm). Dimension Y IMPORTANT The flue restrictor ring must be removed or discarded if the total flue length - including bendsexceeds 1.0m. TE When cutting the horizontal flue terminal or an extension to the required length, you must ensure that the excess is cut from the plain end of the terminal or extension, and that the inner (60mm) pipe is 7,5mm longer than outer (100mm) pipe (see fig. 7 & 8). Remove any burrs, and check that any seals are located properly. You must ensure that the entire flue system is properly supported and connected. Seal the flue assembly to the wall using cement or a suitable alternative that will provide satisfactory weatherproofing. The interior and exterior trim can now be fitted. 110 Fig. 7 7,5 Max. 833mm Dimension X 135mm CONCENTRIC VERTICAL FLUE The vertical flue terminal can be connected directly to the appliance flue outlet. Alternatively, an extension or bend can be connected to the appliance flue outlet if desired (see 4.4.2), however if additional bends are fitted, a reduction must be made to the maximum flue length (see table below). Fig. 8 You must ensure that the entire flue system is properly supported and connected. Seal the flue assembly to the wall using cement or a suitable alternative that provides satisfactory weatherproofing. The exterior trim can now be fitted. Boiler Push-fit connection Extension 7,5 mm EXTENDING THE HORIZONTAL FLUE If the horizontal flue requires extension/s or additional bend/s, the horizontal flue terminal kit ( ) must be used. Connect the bend - supplied with the terminal kit - to the top of the water heater using the clips, screws, & gaskets supplied. The additional bends & extensions have an internal push-fit connection, care should be taken to ensure that the correct seal is made when assembling the flue system. Connect the required number of flue extensions or bends (up to the maximum equivalent flue length) to the flue terminal using the clips, screws & gaskets supplied (see fig. 7 & 8). Bend Reduction for bends 45 bend 0,5 metre 90 bend 1,0 metre Reduction in maximum flue length for each bend Vertical flue terminal and accessories Part No. Description Length Vertical flue terminal Pitched roof flashing plate Flat roof flashing plate 750mm extension 1500mm extension 45 bend (pair) 90 bend Wall bracket (5) 1000 mm 750mm 1500mm Using the dimensions given in fig. 9 as a reference, mark and cut a 105mm hole in the ceiling and/or roof. Fit the appropriate flashing plate to the roof and insert the vertical flue terminal through the flashing plate from the outside, ensuring that the collar on the flue terminal fits over the flashing. The fixing holes for the wall-mounting bracket should now be drilled and plugged, an appropriate type and quantity of fixing should be used to ensure that the bracket is mounted securely. Once the bracket has been secured to the wall, mount the appliance onto the bracket. 7
10 Fig mm minimum 166mm 465mm GUIDANCE TES ON TWIN FLUE INSTALLATION The flue must have a fall back of 1 back to the appliance to allow any condensate that may form in the flue system to drain via the condensate drain. Consideration must also be given to the fact that there is the possibility of a small amount of condensate dripping from the terminal. Ensure that the entire flue system is adequately supported, use at least one bracket for each extension. The entire flue system must be adequately insulated to maintain heat within the flue system thereby reducing the possibility of condensate production. As the exhaust outlet pipe can reach very high temperatures it must be protected to prevent persons touching the hot surface. The condensate drain pipe must be connected in accordance with building regulations. Twin flue accessories The vertical flue terminal is 1.0 metre in length and cannot be cut; therefore it may be necessary to adjust the height of the appliance to suit or use a suitable extension. Remove or discard the flue restrictor ring from the appliance flue outlet (see fig. 1), if the total flue length - including the allowance for any additional bends - exceeds 1.0 metre. Connect the vertical flue assembly to the water heater flue spigot using the 60mm & 100mm clips, gaskets & screws (supplied), ensuring the correct seal is made. The flue support bracket (supplied with the vertical flue kit) can now be fitted. If the vertical flue requires extension/s or additional bend/s, connect the required number of flue extensions or bends (up to the maximum equivalent flue length) between the water heater and vertical flue assembly (see fig. 8). TE When cutting an extension to the required length, you must ensure that the excess is cut from the plain end of the extension and that the inner (60mm) pipe is 7,5mm longer than outer (100mm) pipe (see fig. 8). Remove any burrs, and check that any seals are located properly. You must ensure that the entire flue system is properly supported and connected TWIN FLUE SYSTEM The Vokera twin flue system enables greater flue distances to be achieved (see 4.4.2) than that of the standard concentric flue system. It can be used for horizontal or vertical applications, however the twin flue system must be converted to the dedicated concentric flue kit for termination. It is essential that the installation of the twin flue system be carried out in strict accordance with these instructions. Part No. Description Length Bend 45 bend 90 bend Horizontal flue terminal Vertical flue terminal Concentric to twin, adapter Pitched roof flashing plate Flat roof flashing plate Condensate drain kit 0,25m extension (pair) 0,5m extension (pair) 1,0m extension (pair) 2,0m extension (pair) 45 bend (pair) 90 bend (pair) Twin bracket (5) Single bracket (5) 1000 mm 1000 mm 250mm 500mm 1000mm 2000mm MOUNTING THE WATER HEATER The fixing holes for the wall-mounting bracket should now be drilled and plugged, an appropriate type and quantity of fixing should be used to ensure that the bracket is mounted securely. Once the bracket has been secured to the wall, mount the appliance onto the bracket. Reduction for bends Reduction in maximum flue length for each bend 1,0 metre 1,0 metre INSTALLATION OF CONCENTRIC TO TWIN ADAPTOR KIT (see fig. 10) Remove the flue restrictor ring from the appliance flue outlet (if fitted). Using the two holes in the concentric section of the adaptor as a guide, drill two - 3mm - corresponding holes on the appliance flue outlet. Fit the adaptor to the appliance flue outlet and secure it using the screws provided. 8
11 Fig. 10 Condensate drain kit Mark and drill a 130mm hole for the passage of the horizontal flue terminal, ensuring that there is a 1 fall back to the water heater (17mm per 1000mm). Insert the terminal assembly into the flue hole. Push-fit the twin flue pipes onto the concentric to twin converter box ensuring that the exhaust pipe connects to the exhaust connection on the concentric to twin converter. If necessary cut the plain ends (male) of the twin flue pipes to allow connection to the concentric to twin converter. TE Before cutting twin flue pipes ensure allowances have been made for connection onto the previous piece and onto the concentric to twin converter. The last twin flue pipes must be pushed 50mm onto the male spigots of the concentric to twin converter. You must ensure that the entire flue system is properly supported and connected. Seal the flue terminal assembly to the wall using cement or a suitable alternative that will provide satisfactory weatherproofing. The interior and exterior trim can now be fitted. Fig INSTALLATION OF CONDENSATE DRAIN KIT (see fig. 11) The condensate drain kit must be fitted within 1 metre of the appliance flue outlet. It is recommended that the condensate drain kit should be fitted in the vertical plane, however it can be fitted horizontally with care. Fit the first bend to the condensate drain kit or exhaust connection manifold by firmly pushing in to position. Using the two holes in the exhaust connection manifold as a guide, drill a 3mm hole in each and secure using the screws provided. Connect the air inlet pipe to the air baffle as above. The twin flue pipes extensions and accessories can now be installed by pushing together (the plain end of each extension or bend should be pushed approximately 50mm into the female socket of the previous piece) HORIZONTAL TERMINATION (see fig. 12) The twin flue system must be converted to the dedicated concentric flue kit for termination. The horizontal terminal is supplied with a builtin converter box and cannot be shortened. A 130mm hole is required for the passage of the concentric terminal through the wall. The air inlet pipe must always be level with or below, that of the exhaust pipe. Depending on site conditions it may be preferable to install the terminal assembly prior to fitting the twin flue pipes VERTICAL TERMINATION (see fig. 13) The twin flue system must be converted to the dedicated concentric flue kit for termination. The vertical terminal is supplied with a built-in converter box and cannot be shortened. A 130mm hole is required for the passage of the concentric terminal through the ceiling and/or roof. Depending on site conditions it may be preferable to install the terminal assembly prior to fitting the twin flue pipes. Fit the appropriate flashing plate to the roof and insert the vertical flue terminal through the flashing plate from the outside, ensuring that the collar on the flue terminal fits over the flashing. Push-fit the twin flue pipes onto the concentric to twin converter ensuring that the exhaust pipe connects to the exhaust connection on the concentric to twin converter. If necessary cut the plain ends (male) of the twin flue pipes to allow connection to the concentric to twin converter. TE Before cutting twin flue pipes ensure allowances have been made for connection onto the previous piece and onto the concentric to twin converter. The last twin flue pipes must be pushed 50mm onto the male spigots of the concentric to twin converter. You must ensure that the entire flue system is properly supported and connected. Ensure that any horizontal sections of pipe have a 1 fall towards the appliance (17mm per 1000mm). 9
12 4.6.3 HOT WATER OUTLET (see fig. 4) The appliance is supplied with 15mm connector for the hot water outlet connection, connect a 15mm pipe to the outlet of the connector and tighten the nut. Fig ELECTRICAL CONNECTIONS The electrical supply must be as specified in 3.7. The appliance is supplied, pre-wired with a 0,9 metre length of flex, connect the wires as follows: connect the Brown wire to the L (Live) terminal of the plug or fused isolator; connect the Blue wire to the N (Neutral) terminal of the plug or fused isolator; connect the Green/Yellow wire to the E (Earth) terminal of the plug or isolator; ensure the plug or fused isolator is fitted with a 3-amp fuse. Convertor box CASING REMOVAL To gain internal access to the appliance you must first remove the casing, proceed as outlined below: locate and remove the 4 screws that secure the controls fascia to the appliance casing (see fig. 14); lift the casing upward to disengage it from the top locating hooks and then remove; gently lower the control fascia until it rests; store the casing and screws safely until required. Re-fit in the reverse order. Condensate trap Fig CONNECTING THE GAS AND WATER The appliance is supplied with an accessories pack that contains sealing washers and service valves. The service valves are of the compression type. When connecting pipe work to the valves, tighten the compression end first, then insert the sealing washers before tightening the valve to the appliance. TE It will be necessary to hold the valve with one spanner whilst tightening with another. Fig.14 Screws Screws GAS (see fig. 4) The appliance is supplied with a 15mm service valve, connect a 15mm pipe to the inlet of the valve and tighten both nuts. TE It will be necessary to calculate the diameter of the gas supply pipe to ensure the appliance has an adequate supply of gas COLD INLET (see fig. 4) The appliance is supplied with 15mm stopcock for the cold water inlet connection, connect a 15mm pipe to the inlet of the valve and tighten the nut. Fig.15 Outlet test nipple Inlet test nipple Protective cap 10
13 SECTION 5 COMMISSIONING 5.1 GAS SUPPLY INSTALLATION Inspect the entire installation including the gas meter, test for soundness and purge. Refer to BS 6891 for specific instruction. 5.2 WATER PIPE WORK The water pipe work shall be flushed and tested in accordance with the Water Supply (water fittings) Regulations (Water Byelaws Scotland). 5.3 PRE-OPERATION CHECKS Before attempting the initial lighting of the appliance, the following checks must be carried out: ensure all gas service valves from the meter to the appliance are open and the supply pipe has been properly purged; ensure the proper electrical checks have been carried out (see 7.7), particularly continuity, polarity and resistance to earth; ensure the 3 amp fuse supplied with the appliance has been fitted; ensure the appliance and associated pipe work has been filled and vented; ensure the flue system has been fitted properly and in accordance with the instructions; ensure all appliance service valves are open. 5.4 INITIAL LIGHTING Ensure the electrical supply to the appliance is switched on. Turn the selector knob to the on position (fig. 1). Open a hot water outlet (preferably a bath tap) and ensure the flow rate exceeds 2 litres per minute. The appliance will now go through an ignition sequence as described in 1.2. Should the appliance fail to ignite, refer to 5.3 and/or section 7 (fault finding). 5.5 CHECKING THE BURNER PRESSURE Although the burner pressure is factory set, it is necessary to check it during commissioning. Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test nipple (see fig. 15). Light the appliance as described in 5.4 and compare the reading on the manometer with the values described in 2.2. If adjustement is required, follow the detailed instructions in section 7 (7.3). Once the burner pressure has been checked, isolate the appliance from the electrical supply, remove the manometer, and tighten the gas valve outlet test nipple. 5.6 SETTING THE OUTLET TEMPERATURE The hot water outlet temperature can be adjusted between 40 C - 65 C via the thermostat knob (see fig. 1). 5.7 FINAL CHECKS ENSURE ALL TEST NIPPLES ON THE AP- PLIANCE GAS VALVE HAVE BEEN TIGHTENED AND CHECKED FOR SOUNDNESS. ENSURE THE APPLIANCE FLUE SYSTEM IS FITTED CORRECTLY AND IS PROPERLY SECURED. ENSURE ALL PIPE WORK IS RE-CHECKED FOR SOUNDNESS. RE-FIT APPLIANCE CASING. Complete details of the installation in the warranty card supplied with the appliance. This is an important document, which must be correctly completed and handed to the user. Failure to install and commission the appliance to the manufacturers instructions may invalidate the warranty. 5.8 INSTRUCTING THE USER Hand over all documentation supplied with this appliance including these instructions and explain the importance of keeping them in a safe place. Explain to the user how to isolate the appliance from the gas, water and electricity supplies, and the locations of all drain points. Show the user how to operate the appliance and its controls correctly. Explain to the user how to turn off the appliance for both long and short periods, and advise on the necessary precautions to prevent frost damage. Explain to the user that for continued safe and efficient operation, the appliance must be serviced annually by a competent person. 11
14 SECTION 6 SERVICING 6.1 GENERAL To ensure the continued safe and efficient operation of the appliance, it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the particular installation conditions, but in general, once per year should be adequate. It is the law that any servicing work is carried out by competent person such as a Vokera engineer, an approved service agent, British Gas, or other CORGI registered personnel. The following instructions apply to the appliance, but it should be remembered that the domestic hot water system will also require attention from time to time. 6.2 ROUTINE ANNUAL SERVICING Check the operation of the appliance and ensure it functions as described in section 7. Compare the performance of the appliance with its design specification. The cause of any noticeable deterioration should be identified and rectified without delay. Thoroughly inspect the appliance for signs of damage or deterioration especially the flue system and the electrical apparatus. Check and adjust if necessary all burner pressure settings (see 7.3). Carry out an analysis of the flue gases (see 7.4), and visually check the condition of the entire flue assembly. Compare the results with the appliance design specification. Any deterioration in performance must be identified and rectified without delay. Ensure both flue venturis are clean and free from any debris or obstruction. Ensure both the burner and heat exchanger are clean and free from any debris or obstruction. Inspect all joints for signs of leakage and repair if necessary. Refer to the commissioning section and/or replacement of parts section for detailed instruction if required. drain point. Ensure some water absorbent cloths are available to catch any residual water that may drip from the appliance or removed component. Undertake a complete commissioning check as detailed in section 5, after replacing any component. ALWAYS TEST FOR GAS SOUNDNESS IF ANY GAS CARRYING COMPONENTS HAVE BEEN REMOVED OR DISTURBED. 6.5 NTC THERMISTORS (see fig. 1) Carry out component removal procedure as described in 6.4. Locate and remove the ten screws that secure the air chamber cover. Remove the air chamber cover. Disconnect thermistor electrical plug. Using a 13mm spanner slacken and remove the thermistor and sealing washer. Replace in the reverse order. 6.6 HIGH LIMIT THERMOSTAT (see fig. 1) Carry out component removal procedure as described in 6.4. Locate and remove the ten screws that secure the air chamber cover. Remove the air chamber cover. Pull off electrical connections from the high limit thermostat, slacken and remove retaining screws. Replace in the reverse order. 6.7 FLOW SWITCH (see fig. 16) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Disconnect the cold water inlet pipe from the bottom connection of the flow switch. Disconnect the outlet pipe from the top connection of the flow switch. Detach the electrical plug/ wires from the flow switch. Slacken and remove the lock-nut that secures the flow switch to the lower frame. Replace in the reverse order. 6.3 MENT OF COMPONENTS Although it is anticipated that this appliance will give years of reliable, trouble free service, the life span of components will be determined by factors such as operating conditions and usage. Should the appliance develop a fault, the fault finding section will assist in determining which component is malfunctioning COMPONENT REMOVAL PROCEDURE To remove a component, access to the interior of the appliance is essential. Isolate the appliance from the electrical supply and remove the fuse. And when necessary, close all service valves on the appliance, remove the appliance casing as described in section 4.7.1, drain the water content from the appliance via an outlet or appropriate 1 Screws 2 High limit thermostat 3 Outlet pipe 4 DHW flow switch Fig Locknut 6 Gas valve securing screws 7 Gas valve 12
15 6.7.1 PRINTED CIRCUIT (PCB) (see fig. 17) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Carefully slide out the control panel until the lugs on the lower right and left side of the panel are free from the slots on the appliance frame. Remove the electrode lead from its clip on the PCB housing. Locate and remove the two screws which secure the PCB cover & terminal cover, then remove cover, after carefully taking note of all wiring connections, disconnect all wiring from the PCB, locate and remove the PCB securing screws, remove PCB. Replace in the reverse order. TE Ensure that the replacement PCB has the correct Jumper Tag configuration (see section 8). Disconnect the electrode lead from its connector. Disconnect the gas valve outlet pipe from its connection to the burner. Slacken and remove the lock-nut that secures the burner assembly to the air chamber base. The burner can now be removed. With the burner assembly removed, slacken and remove the burner bar retaining clips in order to gain access to the injectors. Replace in the reverse order. Please note, the injector sealing washers must be replaced if the injectors have been removed, ensure all seals are in good condition, taking care to ensure they are replaced correctly. Fig. 18a Fig GAS VALVE (see fig. 16) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in The gas valve must be changed as complete unit. Disconnect the electrical plug and leads from the gas valve. Disconnect compensator tube from gas valve regulator. Slacken and unscrew gas valve inlet and outlet connections. Please note, the sealing washers must be discarded and replaced with new sealing washers. Locate and remove gas valve retaining screws on the underside of the appliance. The gas valve can now be removed. Replace in the reverse order. Check and adjust burner pressure settings. WARNING, A GAS SOUNDNESS CHECK MUST BE CARRIED OUT. 6.9 BURNER, INJECTORS AND SPARK/SENSE ELECTRODE (see fig. 18a,b,c) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Locate and remove the ten screws that secure the air chamber cover. Remove the air chamber cover. Locate and remove the 5 screws securing the front combustion cover and retaining plate, pull the cover towards you before lowering and disengaging. Fig. 18b Fig. 18c 6.10 FLUE FAN (see fig. 19) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Locate and remove the 10 screws that secure the air chamber cover. Remove the air chamber cover. Locate and remove the 4 screws that secure the flue assembly. Disconnect the electrical connections and silicone tubes attached to the fan, noting their positions. Disconnect the maintainence clip that secures the flue outlet pipe to the fan, ease the fan & flue hood assembly from its location. Locate and remove the screws that secure the fan to the flue hood. Remove the fan 13
16 to flue elbow. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. Fig HEAT EXCHANGER (see fig. 20) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Locate and remove the 10 screws that secure the air chamber cover. Remove the air chamber cover. Locate and remove the 5 screws securing the front combustion cover and retaining plate. Disconnect the inlet and outlet connections on the heat exchanger. The heat exchanger can now be withdrawn from the appliance (if necessary, the burner should be removed to facilitate access to the connections). Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. Fig AIR PRESSURE SWITCH (see fig. 1) Carry out component removal procedure as described in 6.4. Remove the appliance casing as described in Locate and remove the 10 screws that secure the air chamber cover. Remove the air chamber cover. Locate and remove the two screws holding the air pressure switch to the air chamber. Disconnect the electrical connections and silicone tubes attached to the air pressure switch, noting their positions. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. SECTION 7 CHECKS, ADJUSTMENTS, AND FAULT FINDING 7.1 CHECKING APPLIANCE OPERATION When carrying out any repairs or servicing to the appliance, the relevant commissioning procedure must be undertaken to ensure the continued safe operation of the appliance. Particular attention should be made to ensure gas soundness, water soundness, and the electrical integrity of the appliance. 7.2 APPLIANCE MODE OF OPERATION When there is a request for hot water via a hot water outlet or tap, the water flow switch senses water movement thereby energising the fan. TE There must be sufficient inlet water pressure and flow (min. 0,15 bar/ 2 lpm) to ensure the water flow switch is activated. If there is insufficient pressure and/or flow, the appliance will be prevented from operating. When the fan runs, it proves the differential air pressure switch which in-turn allows an ignition sequence to begin. TE The ignition sequence lasts approximately 7 seconds, during which the appliance will continue to spark even if the burner has already lit. If the spark/sensing electrode does not sense ignition the appliance will then go to lockout. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry allows the full gas rate through the appliance. When the appliance reaches the desired temperature the burner will modulate to maintain the set temperature. Should the temperature continue to rise the burner will shut off when the maximum operating temperature is attained. When the request for heat and/or hot water has been satisfied, the fan may continue to operate to dissipate any residual heat within the appliance. 7.3 CHECKING AND ADJUSTING BURNER PRESSURE (see fig. 17) Altough the burner pressure is factory set, it is necessary to check it during servicing or if the gas valve has been removed. Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test nipple. Remove the compensator tube SETTING THE MAXIMUM BURNER PRESSURE Light the appliance as described in 5.6 and compare the reading on the manometer with the value described in 2.2. If adjustement is required, remove the protective cap from the gas valve modulating coil assembly and turn the outer (10mm) nut clockwise to increase, or counterclockwise to decrease the burner pressure. 14
17 TE You should ensure that one or two hot water outlets are fully open during the above procedure. This will ensure that the output of the appliance (burner pressure) is not compromised due to a high outlet temperature SETTING THE MINIMUM BURNER PRESSURE Once the maximum burner pressure has been checked and/or adjusted, remove one of the grey wires from the modulating coil. Compare the reading on the manometer with the value described in 2.2. If adjustement is required, turn the inner (red) cross-head screw clockwise to increase, or counter-clockwise to decrease the burner pressure, whilst ensuring that the outer (10mm) nut does not move. When checking and/ or adjustement has been completed, isolate the appliance from the electrical supply, replace the protective cap, refit the compensator tube, refit the grey wire to the modulating coil, remove the manometer, and tighten the outlet test nipple. IMPORTANT: A GAS SOUNDNESS CHECK MUST BE CARRIED OUT. 7.4 EXTERNAL FAULTS Before carrying out any fault-finding or component replacement, ensure the fault is not attributable to any aspect of the installation INSTALLATION FAULTS Symptom No ignition Poor hot water Unstable flame picture Possible causes Check external wiring. Check cold supply is connected to cold inlet. Check gas supply. Check adjust flow rate. Check flue system 7.5 ELECTRICAL CHECKS Any electrical checks must be carried out by a suitably qualified person EARTH CONTINUITY TEST Isolate the appliance from the electrical supply, and using a suitable multi-meter carry out a resistance test. Connect test leads between an appliance earth point and the earth wire of the appliance supply cable. The resistance should be less than 1 ohm. If the resistance is greater than 1 ohm check all earth wires and connectors for continuity and integrity SHORT CIRCUIT CHECK Isolate the appliance from the electrical supply, and using a suitable multi-meter, carry out a short circuit test between the Live & Neutral connections at the appliance. Repeat above test on the Live & Earth connections at the appliance term. TE Should it be found that the fuse has failed but no fault is indicated, a detailed continuity. Check will be required to trace the fault. A visual inspection of components may also assist in locating the fault POLARITY CHECK With the appliance connected to the electrical supply and using a suitable multi-meter, carry out the following voltage tests: connect test leads between the Live & Neutral connections at the appliance. The meter should read approximately 230V ac. If so proceed to next stage. If not, see connect test leads between the Live & Earth connections at the appliance. The meter should read approximately 230V ac. If so proceed to next stage. If not, see Connect test leads between the Neutral & Earth connections at the appliance. The meter should read approximately 0 15Vac. If so polarity is correct. If not, see REVERSED POLARITY OR SUPPLY FAULT Repeat the above tests at the appliance isolator, if testing reveals correct polarity and/or supply at the isolator, re-check wiring and connections between the isolator and the appliance. If tests on the isolator also reveal reversed polarity or a supply fault, consult the local electricity supplier for advice RESISTANCE TO EARTH CHECK Isolate the appliance from the electrical supply, and using a suitable multi-meter carry out a resistance test. Connect test leads between the Live & Earth connections at the appliance. If the meter reads other than infinity there is a fault that must be isolated, carry out a detailed continuity check to identify the location of the fault. IMPORTANT These series of checks must be carried out before attempting any fault-finding procedures on the appliance. On completion of any task that required the disconnection and re-connection of any electrical wiring or component, these checks must be repeated. 7.6 FAULT FINDING Before attempting any fault-finding, the electrical checks as detailed in 7.5 must be carried out. Isolate the appliance from the electrical supply and remove the casing and PCB cover. Restore the electrical supply to the appliance, turn the selector switch to the on position, and open a hot water outlet. The appliance should now function as described in section 7.2. Should the appliance fail to respond, the internal fuse and connectors should be checked to ensure 15
18 integrity and continuity. If the appliance still fails to respond, refer to the detailed fault-finding flowcharts overleaf. 7.7 FAULT CODES Green LED Red LED Status Action required On for 1 second, off for 5 seconds Off Switched off or at stand-by NE On Off Off On DHW request Flame lockout NE Check gas supply, check ignition sequence On Flashing on/off every 0,5 seconds Overheating Allow to cool, check operation of appliance Flashing on/off every 0,5 seconds Off Air pressure switch open Check flue system, check air pressure switch and/on fan Flashing on/off every 0,5 seconds Flashing on/off every 0,5 seconds NTC thermistor fault Check NTC thermistor 16
19 FAULT FINDING TEST 1 START SWITCH ON WATER HEATER AND SELECT WATER TEMPERATURE AT MAX. MAINS PRESENT BETWEEN TERMINALS 8 & 9 ON ACF TURN ON TAP WITH A FLOW RATE > THAN 2.5 LIT/MIN MAINS ON FAN CHECK &/OR WIRING AND CONNECTIONS MAINS PRESENT BETWEEN TERMINALS 4 & 11 ON ACF MAINS PRESENT BETWEEN TERMINALS X1.1 & X1.2 ON DRIVER LINE LAMP LIGHT? CHECK WIRING BETWEEN MAIN SWITCH AND DRIVER FAN MAINS PRESENT BETWEEN TERMINALS 7 & 11 ON ACF ACF CHECK &/OR WIRING AND CONNECTIONS A1 CHECK &/OR REPALCE FUSE F3 MAIN SWITCH AND SUPPLY & CONNECTORS TO BOILER TERMINALS MAINS PRESENT BETWEEN TERMINALS 10 & 11 ON ACF CHECK &/OR WIRING AND CONNECTIONS CHECK WIRING AND CONNECTIONS OR SAFETY THERMOSTAT LINE LAMP LIGHT? FAN RUNNING MAINS PRESENT BETWEEN TERMINALS X1.5 & X1.6 ON DRIVER MAINS PRESENT BETWEEN TERMINALS X1.1 & X1.9 ON DRIVER MAINS PRESENT BETWEEN TERMINALS X1.1 & X1.2 ON DRIVER DRIVER A MAINS PRESENT BETWEEN TERMINALS X1.1 & X1.8 ON DRIVER DRIVER CHECK FUSES F1 & F2 ON DRIVER FUSES OK FUSES CHECK WIRING BETWEEN MAIN SWITCH AND DRIVER CHECK &/OR REPALCE FUSE F3, MAIN SWITCH AND SUPPLY & CONNECTORS TO BOILER TERMINALS RESTART THE TEST 17
20 FAULT FINDING TEST 2 A SPARK AT ELECTRODE IGNITION MAINS PRESENT BETWEEN TERMINALS 6 & 11 ON ACF MODULATION TEST SENSING ELECTRODE AND LEAD LOCKOUT AFTER IGNITION CHEK SENSING ELECTRODE AND LEAD SENSING ELECTRODE AND LEAD OK A2 A.C.F. IS THERE VOLTAGE AT SPARK ELECTRODE PIN? ATTENTION!! VOLTAGE > 10 kv CHECK SPARK ELECTRODE AND LEAD CHECK WIRING AND CONNECTIONS AND AIR FLOW SWITCH DO THE AIR FLOW SWTCH TURN ON IS THERE A GAS INPUT PRESSURE GREATHER THAN 13.7 mbar EVG IS THERE MECHANICAL OPENING OF GAS VALVE SOLEIDS CHECK/CLEAN THE VENTURI TUBE AND SILICONE AIR TUBES ARE THE VENTURI TUBE AND THE SILICONE AIR TUBES CLEAN CHECK GAS A.C.F. OK IS THE AIR DP > 11 mmch2o EVG CHECK AIR FLOW SWITCH A.C.F. CHECK THE FAN AND/OR FLUE GAS TUBE 18
21 FAULT FINDING TEST 3 MODULATION TEST IS THERE A VOLTAGE >10 Vdc BETWEEN TERMINALS X3.3 & X3.4 ON PCB IS THE RESISTENCE OF MODULATOR COIL ABOUT 70/80 OHM MODULATOR COIL IS THE WATER FLOW SENSOR OK CONTROL IS VOLTAGE ACROSS TERMINALS OF MODULATOR COIL > 10 Vdc WATER FLOW SENSOR SWITCH WATER THERMOSTAT AT MIN. WAIT TILL THE VOLTAGE BETWEEN TERMINALS X3.3 & X3.4 ON PCB IS < 1.2 Vdc IS VOLTAGE ACROSS TERMINALS OF MODULATOR COIL < 1.2 Vdc WAIT WATER TEMPERATURE >60 C WAIT WATER TEMPERATURE > 40 C IS THERE A VOLTAGE >10 VDC BETWEEN TERMINALS OF MODULATOR COIL IS WATER TEMPERATURE > 40 C MODULATOR COIL CONTROL DO BURNER AND FAN SWITCH OFF SWITCH WATER THERMOSTAT AT MAX. IS WATER TEMPERATURE >60 C IS NTC SENSOR OK CHECK AND NTC SENSOR IS WATER FLOW SENSOR OK WIRE AND CONNECTIONS WAIT WATER DO BURNER AND FAN SWITCH ON CONTROL WATER FLOW SWITCH TEMPERATURE < 60 C A3 IS WATER TEMPERATURE > 60 C CONTROL 19
22 FAULT FINDING TEST 4 A1 MAINS PRESENT BETWEEN TERMINALS 5 & 11 ON ACF MAINS PRESENT BETWEEN WHITE WIRE ON AIR FLOW SWITCH AND PIN 11 ON ACF ACF CHECK &/OR WIRING AND CONNECTIONS MAINS PRESENT BETWEEN RED WIRE ON AIR FLOW SWITCH AND PIN 11 ON ACF IS AIR FLOW SWITCH CONTACT ON N.C. POSITION CHECK &/OR WIRING AND CONNECTIONS CHECK &/OR AIR FLOW SWITCH CHECK FLUE GAS TUBE A3 A2 TURN OFF TAP THE POLARITY OF FEEDING IS INVERTED INVERT THE POLARITY OF FEEDING DO BURNER AND FAN SWITCH OFF THE FEEDING IS PHASE PHASE END IS WATER FLOW SENSOR OK ACF INSTALL PHASE PHASE KIT WATER FLOW SENSOR CHECK WIRING AND CONNECTION OR CONTROL 20
23 SECTION 8 WIRING DIAGRAMS 8.1 EXTERNAL WIRING The appliance comes with a factory fitted cable that should be connected to a suitable fused isolator or plug. If this is unsuitable and a direct connection to the appliance is required, it must be connected to the appliance as shown in the following diagram. For further advice on the electrical connection, please contact Vokera technical on FUNCTIONAL DIAGRAM TE: L-N connection is advisable TR1 TR2 JP1 P.F. T.L. SAN F1 E.A.R. RL1 DHW temperature control Selector ON/OFF Natural gas or LPG selector jumper Air pressure switch High limit thermostat Flow switch Fuse 2A F Sense/ignition electrode Fan relay RL2 Ignition relay MOD Modulator V Fan IWH01X Control board T1 Transformer OPE Gas valve solenoids CN1-CN7 Connectors T2 Ignition/transformer 21
24 FUNCTIONAL DIAGRAM pink blue brown white TE: L-N connection is advisable grey grey red red black black white purple purple brown blue 22
25 SECTION 9 EXPLODED DIAGRAMS A B Pos Description Code Cable Wall bracket W Air chamber top Back panel W Silicone tube Pressure differential switch Air chamber front panel W Casing clip W White casing Earthing strip PCB Sight glass retaining ring W Sight glass seal W Sight glass W131A 14 Air chamber bottom Lower panel Cable entry socket Rivet PCB cover Control panel Led lens Selector/thermostat knob Adhesive logo Air chamber seal W Wall plug W98A 25 Screw 6,5mm x 2,9mm Rivet 6mm x 3mm W21M1 27 Screw 12mm x 3,5mm Screw 6mm x 3,5mm W127G 29 Screw 13mm x 3,9mm W113A 30 Screw 13mm x 4,8mm W242D1 31 Screw 25mm x 4,8mm Screw 7mm x 4,8mm W74N 33 Screw 9mm x 3,9mm W Nylon shaft Nylon shaft
26 Tav. 1 A B Pos Description Code 1 Exhaust restrictor ring W mm pipe W Gasket Clip Negative venturi W Positive venturi W Fan to flue connector Fan to flue connector W Fan gasket W92A 10 Flue hood W Flange W Heat exchanger Washer NTC thermistor Coupling W Electrode W Securing plate W Lead Combustion cover W Burner (natural gas) W Burner (LPG) W Burner coupling W Nipple Flow restrictor Inlet pipe DHW flow switch Gas valve Gas valve outlet pipe Outlet pipe High limit thermostat /2 bsp locknut Screw M4 x 7mm Screw 6,5mm x 2,9mm Fibre washer Fibre washer /2 bsp locknut W5C Spring clip W Screw 6mm x 3,5mm W127G 38 Screw 38mm x 4,2mm Screw 9mm x 4,2mm W Screw 7mm x 4,8mm W74N 41 Screw 9,5mm x 3,9mm W95A 42 1/8 bsp locknut Screw 3,9mm x 19mm W114A 44 Flow restrictor
27 SECTION 10 L.P.G. INSTRUCTIONS For details of converting an appliance to LPG please refer to the instructions supplied with the relevant conversion kit TECHNICAL DATA Inlet pressure (LPG) Maximum burner pressure Minimum burner pressure Gas rate Injector size 37 mbar 36 mbar 3,0 mbar 1,33m 3 /h 15 x 0,77mm 10.2 RELATED DOCUMENTS BS 5440 BS 5440 BS 5546 BS 6891 BS 5482 PART 2 PART 1 PART 1 FLUES FLUES & VENTILATION INSTALLATION OF GAS HOT WATER SUPPLIES FOR DOMESTIC PURPOSES LOW PRESSURE INSTALLATION PIPES DOMESTIC BUTANE & PROPANE GAS BURNERS IN PERMAMENT DWELLINGS 10.3 GAS SUPPLY The gas supply must be connected to the appliance by a competent LPG installer and must be of sufficient size to supply the appliance at its maximum output. An existing supply must be checked to ensure that it is of adequate size to deal with the maximum rated input of this and any other appliances that it serves GAS SUPPLY INSTALLATION The entire installation, including the meter, must be purged and checked for gas soundness CHECKING AND ADJUSTING BURNER PRESSURE (see fig. 17) Although the burner pressure is factory set, it is necessary to check it during servicing or if the gas valve has been removed. Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test nipple. Remove the compensator tube SETTING THE MINIMUM BURNER PRESSURE Once the maximum burner pressure has been checked and/or adjusted, remove one of the grey wires from the modulating coil. Compare the reading on the manometer with the value described in 2.2. If adjustement is required, turn the inner (red) cross-head screw clockwise to increase, or counter-clockwise to decrease the burner pressure, whilst ensuring that the outer (10mm) nut does not move. When checking and/ or adjustement has been completed, isolate the appliance from the electrical supply, replace the protective cap, refit the compensator tube, refit the grey wire to the modulating coil, remove the manometer, and tighten the outlet test nipple. IMPORTANT, A GAS SOUNDNESS CHECK MUST BE CARRIED OUT SETTING THE MAXIMUM BURNER PRESSURE Light the appliance as described in 5.6 and compare the reading on the manometer with the value described in 2.2. If adjustement is required, remove the protective cap from the gas valve modulating coil assembly and turn the outer (10mm) nut clockwise to increase, or counterclockwise to decrease the burner pressure. TE You should ensure that one or two outlets are open during the above procedure. This will ensure that the output of the appliance (burner pressure) is not compromised due to a high outlet temperature. 25
28 1 Cod /04 - Ed. Registered address: Vokèra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG [email protected] Sales, General Enquires T F Vokèra Ireland West Court, Callan Co Kilkenny T F Vokèra Limited reserve the right to change specification without prior notice Consumers statutory rights are not affected. A Riello Group Company. Company Reg No:
Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
Mynute 25 A High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims
MULTIPOINT BF Gas Fired Balanced Flue Water Heater
Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 GB (04.10) JS Natural Gas Main Multipoint
Verve. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
Verve High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to
Alpha CD13R,18R and 24R
Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler
Installation and Servicing Instructions Eco Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler For Technical help or for Service call... ALPHA HELPLINE Tel:
Installation & Servicing Instructions
The Range Linea 24 Linea 28 Installation & Servicing Instructions British Gas Service Listed G.C. No. 47 094 27 (Linea 24) G.C. No. 47 094 28 (Linea 28) G.C. No. 47 094 29 (Linea Plus) THESE INSTRUCTIONS
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Excel. High efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. Excel 25 G.C. N 47-364-12 Excel 29 G.C.
Excel High efficiency combi boiler Users Instructions Installation & Servicing Instructions Excel 25 G.C. N 47-364-12 Excel 29 G.C. N 47-364-13 THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Mikrofill Ethos Condensing combination boiler
Mikrofill Ethos Condensing combination boiler Installation Instructions 24cc CE Mark No: 0201055 British Gas Service Listing G.C.No: 47-157-01 Mikrofill gas appliances comply with the requirements contained
Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers
Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870
Alpha InTec 12S, 18S, 28S
Installation and Servicing Instructions Alpha InTec 2S, 8S, 28S Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
Flue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options
Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet
ferroli Boiler Replacement Optimax HE- Modena HE
ferroli Boiler Replacement Optimax HE- Modena HE Introduction The new Ferroli Modena 32C HE high efficiency condensing combination boiler is an ideal replacement for the Ferroli Optimax HE 31 C and the
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Installation and Servicing Instructions
Installation and Servicing Instructions Alpha Pro Tec 50, 70, 90 and 5 Wall Mounted, Fan Assisted, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service call... ALPHA HELPLINE
Alpha InTec 30GS and 40GS
Installation and Servicing Instructions Alpha InTec 30GS and 40GS Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers with a Passive Flue Gas Heat Recovery
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler
Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler Installation and Servicing Instructions BAXI Page 2 Natural Gas Baxi Bahama 100 G.C.Nº 47 075 02 Baxi Limited is one of the leading manufacturers
HeatSource HS1800 Heater
HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:
Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler
User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
GREENSTAR 60/100 HORIZONTAL FLUE
FLUE KIT INSTALLATION MANUAL 7 76 9 08 ROOM SEALED TELESCOPIC FLUE 7 76 9 7 ROOM SEALED LONGER TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR WORCESTER GREENSTAR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Combi 30 HE. Installation & Service Instructions
Installation & Service Instructions Combi 30 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 2009 Natural Gas Main
HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE
INSTALLATION & SERVICING INSTRUCTIONS FOR THE HALSTEAD CAST IRON HALSTEAD Best db 0/40/50/60 WALL MOUNTED FAN ASSISTED BOILER B R I T I S H M A D E B O I L E R S Best 0 G. C. No. 4 50 Best 40 G. C. No.
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005
CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Betacom. 24c G.C. No. 47-019-08. 30c G.C. No. 47-019-09. Installation and Servicing. High Efficiency Condensing Combination Boilers
bar 3 4 5 2 6 1 7 24 8 23 9 22 10 21 11 20 12 19 13 18 14 17 16 15 Betacom Installation and Servicing 24c G.C. No. 47-019-08 30c G.C. No. 47-019-09 High Efficiency Condensing Combination Boilers ON 30
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2
SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
-- ---- I u SYSTEM BOILER. Central Heating Faned Flue system. Installation. System 40. System 60. heygfj& AA
-- ---- I u SYSTEM BOILER Central Heating Faned Flue system System 40 System 60 Installation Operating and instructions heygfj& v AA These instructions are suitable for the following boilers : Britony
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product
INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW 242/1 E. TURBOmax VUW 282/1 E
INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW / E TURBOmax VUW 8/ E Wall hung room sealed fan assisted combination boilers HEATING, CONTROLS, HOT WATER. Page. Introduction. Boiler Specification.
High Efficiency Boiler Range Technical Guide
High Efficiency Boiler Range Technical Guide Glow-worm Nottingham Road Belper Derbyshire DE56 1JT Head Office: 01773 824 639 Literature: 01773 596 105 After Sales Service: 01773 596 510 Technical Advice:
Spare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces
Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Kemlan Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
24CDi/28CDi/35CDi II RSF
Bosch Group 24CDi/28CDi/35CDi II RSF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS 24CDi 28CDi 35CDi II GC NUMBER (N.G) 47
80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500
Release R.2.0 Uk 80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Installation User and Service Manual www.state-waterheaters.co.uk your installer Warning Read this manual carefully before first
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Aerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Elson 10/15L Unvented Water Heater
Elson 10/15L Unvented Water Heater Installation and User Instructions Model: EUV10, EUV15. Please read and understand these instructions before starting work. Please leave this leaflet with the user following
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1
Visage Digital Exposed with adjustable height head The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60
GAS CONTINUOUS FLOW WATER HEATERS INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60 2 INSTALLATION INSTRUCTIONS IMPORTANT SAFETY
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Instructions for installation and servicing ecomax
For the installer Instructions for installation and servicing ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/2 E ecomax 68/2 E ecomax 622/2 E ecomax 635 E ecomax 824/2 E ecomax
Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual
Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual CONTENTS SECTION PAGE 1.0 INTRODUCTION 3 2.0 TECHNICAL SPECIFICATION 4 3.0 INSTALLATION - IMPORTANT INSTALLATION POINTS 7 4.0 INSTALLATION
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
Installation and Servicing Instructions. Type C Boilers LEAVE THESE INSTRUCTIONS WITH THE END-USER
2 1 5 6 2 1 5 6 Installation and Servicing Instructions Type C Boilers microgenus HE 2 MFFI G.C.N: 7-116-7 microgenus HE 28 MFFI G.C.N: 7-116-8 microgenus HE 2 MFFI G.C.N: 7-116-9 LEAVE THESE INSTRUCTIONS
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions
Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425