Agilent Technologies 3000 Series Oscilloscopes



Similar documents
NEW PRODUCT ANNOUCEMENT

U1602A Handheld Oscilloscopes, 20 MHz

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

Digital Storage Oscilloscopes TDS2000C Series Datasheet

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent E5100A Network Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Digital Storage Oscilloscope TBS1000B-EDU Series Datasheet

DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits

Handheld Digital Storage Oscilloscopes 2510 Series

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

How To Use A High Definition Oscilloscope

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

Digital Storage Oscilloscopes

User Manual. Digital Storage Oscilloscope DSO25 / DSO100. Version No.: V 1.6

Analogue/Digital Analogue and Differential Oscilloscopes

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

DSO-1062D/DSO-1102D/DSO-1202D different bandwidths. Digital Oscilloscope User Manual

Agilent 54621A/22A/24A/41A/42A Oscilloscopes and Agilent 54621D/22D/41D/42D Mixed-Signal Oscilloscopes. User s Guide

200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

The Next Generation in Automated Oscilloscope Test

Table of Contents. SAFETY INSTRUCTION...6 Safety Symbols... 6 Safety Guidelines... 7 Power cord for the United Kingdom... 9

Agilent 4339B/4349B High Resistance Meters

Digital Storage Oscilloscopes

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Agilent 4338B Milliohm Meter

Agilent E6832A W-CDMA Calibration Application

DSO8000E SERIES HANDHELD OSCILLOSCOPE

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Embest DSO2300 USB Oscilloscope

Agilent Television Power Consumption Testing. Application Note

Agilent 8753ET/8753ES Network Analyzers

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent InfiniiVision 5000/6000/7000 Series Oscilloscopes

Table of Contents 1. USAGE PRECAUTIONS AND RECOMMENDATIONS GENERAL DESCRIPTION AND FEATURES FIRST TIME OPERATION...9

How To Test A Computer With A Powerline 2.5 (Powerline) And Powerline (Powerplant) (Powerboard) (Awn) (Ios) (Mini Computer) (Microphone) (Wireless) (

R&S ZNC Vector Network Analyzer Specifications

Digital Phosphor Oscilloscopes TDS3000C Series

Agilent U2000 Series USB Power Sensors

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

OX 7100 Series AR RA NT Y

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Selecting RJ Bandwidth in EZJIT Plus Software

Lab 1: The Digital Oscilloscope

Keysight U2701A/U2702A USB Modular Oscilloscope

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

khz to 2.7 GHz Spectrum Analyzer

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Digital Storage Oscilloscopes

User Manual. SDS1000DL/CNL/CML Series. Digital Storage Oscilloscope. Version No.: V 1.0. SIGLENT TECHNOLOGIES Co,.LTD

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

UT4000. Series USER MANUAL. Digital Storage Oscilloscope

Digital Phosphor Oscilloscopes

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Agilent U2000 Series USB Power Sensors

R&S ZNBT8 Vector Network Analyzer Specifications

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Agilent 8904A Multifunction Synthesizer dc to 600 khz

DSO Nano v3 - Wiki. Contents. Introduction

User s Manual of OWON Colour Digital Storage Oscilloscope

FFT Spectrum Analyzers

Arbitrary/Function Generators AFG3000C Series Datasheet

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

One Port Network Analyzer

Agilent Measuring Noninsertable Devices

HP 54710A, 54710D, 54720A and 54720D Oscilloscopes

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

USER S MANUAL. Hantek6022BE. V1.0.3

iva Cable & Antenna Analyzer

Agilent InfiniiVision 3000 X-Series Oscilloscopes. User's Guide

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent: Profile of Oscilloscope Firsts

WXGA (1280 x 800), 3500 lumens, up to 7,000 hours lamp, HDMI, throw ratio, wireless ViewSync

Agilent 8720 Family Microwave Vector Network Analyzers

Impedance 50 (75 connectors via adapters)

Digital Storage Oscilloscope

Multi-Range Programmable DC Power Supplies 9115 Series

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

Analyser-Oscilloscopes

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

User Manual TDS3000 Series Digital Phosphor Oscilloscopes

DL1620/DL1640/DL1640L

Improving Chromatic Dispersion and PMD Measurement Accuracy

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Transcription:

Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm (5.7-in) color display Advanced triggering including edge, pulse width, and line-selectable video 4 kpts of waveform memory 20 automatic measurements plus hardware counter and Measure All Four math functions, including FFTs standard Mask test standard USB, GPIB and RS-232 connectivity available Multi-language support Sequence mode (segmented memory) standard Get more for your money Agilent s 3000 Series oscilloscopes give you an affordable way to see what s happening in your designs. Developed with the features you need to make your job easier including a large LCD color display the new 3000 Series oscilloscopes cost 20% less than competitive oscilloscopes with comparable performance. Need flexibility? Choose from four models with bandwidths ranging from 60 MHz to 200 MHz. To give you the debugging power you need, each oscilloscope comes standard with advanced features including sophisticated triggering, automatic measurements, digital filtering, sequence mode acquisition, math functions (including FFTs), stored setups and waveforms, mask testing and much more.

See your signals more clearly All 3000 Series models have color displays to allow you to quickly identify your signals, and the large size 15 cm (5.7 in) with 320 x 240 resolution makes it easier for you to see more information. The 3000 Series delayed sweep also lets you see more details in your design. You can view a long record, then window in on the section of the signal of interest. Figure 1. All 3000 Series oscilloscopes come standard with a color display and cost 20% less than competitive products. The color display allows you to quickly and easily identify your signals and view signal activity. Figure 2. Want to see the big picture but still get all the details? Use the delayed sweep mode to zoom in on a particular area of interest on your signal while still viewing the entire captured waveform. 2

The features you need All 3000 Series scopes include the standard features you need to get your job done easier and faster: Autoscale Autoscale lets you quickly display any active signals, automatically setting the vertical, horizontal and trigger controls for the best signal display. More memory The 3000 Series oscilloscopes come standard with 4 kpts of memory, nearly twice the memory depth of competitive oscilloscopes in this class. Easy connectivity The Scope Connect software provides optional connectivity for most data gathering, storage and documentation needs, usable with the 3000 series standard USB port. GPIB and RS-232 interfaces are also available as options. Advanced triggering Includes edge, pulse width and line-selectable video, to help you isolate the signals you want to see. 20 automatic measurements To save time, you can make 18 different measurements simultaneously. Waveform math with FFTs Analysis functions include addition, subtraction, multiplication, and Fast Fourier Transforms with four windows (Hanning, Hamming, Blackman- Harris and rectangular). Auto calibration Automatically calibrates the oscilloscope s vertical and horizontal systems. Multi-language interface Operate the oscilloscope in the language of your choice. Language support includes simplified and traditional Chinese, Japanese, Korean, French, German, Italian, Portuguese, Russian and English. Figure 3. The 3000 Series comes equipped with a broad set of measurement and math features, including FFTs at no additional cost. You can choose between 4 FFT windows for your specific measurement needs: Hanning, Hamming, Blackman-Harris, and rectangular. 3

The features you need (continued) Digital filtering Digital filtering selections include low pass, high pass, band pass, and band reject filters. Limits are selectable between 1 khz and the bandwidth of your oscilloscope model. Ten waveform and setup memories Store waveforms or commonly used setups for future reference and use. Figure 4. The digital filter capability enhances your ability to examine important signal components by filtering out undesired spectral components such as various types of noise. Mask testing Automatically compares incoming signals with a pre-defined mask, clearly highlighting signal changes. Sequence mode (segmented memory) Frame an area of interest on your signal for acquisition and record up to 1,000 frames for playback. Pulse triggering Lets you trigger on pulse events. 1-year warranty All 3000 Series scopes include a full 1-year warranty with optional 3-year and 5-year warranty coverage. Figure 5. Use the sequence mode to frame an area of interest on your signal for acquisition; then, use the playback feature to quickly play through the sequence and easily spot glitches or other signal anomalies. Easy to set up and use Dedicated, color-coded knobs for vertical sensitivity, offset, and time base settings make it easy to set up and use. Front-panel keys for triggering functions are also grouped to make your job easier. Figure 6. With dedicated, color-coded knobs and front-panel keys grouped by function, it is easy to find and use all of the features of the scope from the most basic to the more advanced functions. 4

Performance characteristics Performance characteristics Bandwidth* DSO3062A: 60 MHz DSO3102A: 100 MHz DSO3152A: 150 MHz DSO3202A: 200 MHz Real time sample rate 2 channels interleaved 1 GSa/s Each channel 500 MSa/s Channels 2 Display Memory Vertical resolution Vertical sensitivity DC gain accuracy Vertical zoom Maximum input voltage Time base range BW limit Input coupling Input impedance Time base accuracy Color, 320 x 240 1/4 VGA LCD; H: 88 mm, W: 116 mm 4 kpts per channel 8 bits 2 mv/div to 5 V/div ± 3% for 10 mv/div to 5 V/div; ± 4% for 2 mv/div to 5 mv/div Vertical expand 300 Vrms CAT II; derated at 20 db/decade above 100 khz to 13 V p-p AC at 3 MHz and above 2 ns/div to 50 s/div ~ 20 MHz DC, AC, Ground 1 MΩ: 13 pf 100 ppm * Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 C from firmware calibration temperature. 5

Performance characteristics (continued) Performance characteristics (continued) Acquisition modes Normal Displays sampled data directly to the screen in real time Averaging Selectable from 2, 4, 8, 16, 32, 64, 128 or 256 Peak detect Captures high-frequency glitches as narrow as 10 ns when viewing signals at slower sweep speeds (slower than 5 µs/div) Sweep modes Trigger coupling Trigger modes Force Edge Video Pulse triggering Trigger source Cursors Modes Type Measurements Automatic measurements Voltage Time Math functions FFT Window modes Sample size Autoscale Display Interpolation Display types Persistence Format Auto, Normal, Single AC, DC, LF reject, HF reject Triggers immediately when front-panel button is pushed Triggers on the positive or negative slope on any channel Triggers on one of three standard television waveforms: NTSC, PAL, SECAM Triggers on a pulse width greater than, equal to, or less than a specified time limit, with time limits ranging from 20 ns to 10 s Ch 1, 2, Ext, Ext/5, Line (edge mode only) Manual, auto, track Time and voltage T, V, frequency 20 plus 5-digit hardware counter Peak-to-peak, maximum, minimum, average, amplitude, top, base, Vrms, overshoot, preshoot Frequency, period, +width, width, +duty cycle, duty cycle, rise time, fall time, delay, phase Add, subtract, multiply, FFT Hanning, Hamming, Blackman-Harris, rectangular 1024 points Single button automatic setup of all channels 1/4 VGA (320 x 240), passive color LCD with adjustable brightness Sin(x)/x Dots and vectors Off, infinite YT and XY 6

Performance characteristics (continued) I/O Standard ports Optional ports Maximum data transfer rates USB (Requires N2860A Scope Connect software for use) GPIB, RS-232 GPIB: 500 kbytes/sec General characteristics Physical size Weight 30 cm wide x 15 cm high x 29 cm deep (without handle) 34.6 cm wide x 18.2 cm high x 29 cm deep (with handle) Net: 4.8 kgs (10.5 lbs) Shipping: 7 kgs (15 lbs) Power requirements Line voltage range Line frequency Power usage 100-240 VAC, CAT II, automatic selection 47 Hz to 440 Hz 50 VA Environmental characteristics Ambient temperature Operating 0 C to +55 C; non-operating 40 C to +70 C Humidity Altitude Vibration Shock Pollution degree2 Operating 95% RH at 40 C for 24 hr; non-operating 90% RH at 65 C for 24 hr Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft) Agilent class B1 Agilent class B1 Normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation must be expected. 7

Ordering information Model number DSO3062A DSO3102A DSO3152A DSO3202A 60 MHz 2-ch DSO 100 MHz 2-ch DSO 150 MHz 2-ch DSO 200 MHz 2-ch DSO Accessories included Quick Start manual, CD-ROM with User s Guide and Programmer s Manual, power cord, accessory pouch, two passive probes Optional accessories N2861A (communication module) Provides GPIB and RS-232 connectivity and pass/fail output for automatic testing. Includes 3000 Series Scope Connect software (N2860A). N2860A Provides easy communication and control of the (3000 Series Scope Agilent 3000 Series oscilloscopes. Does not require Connect software) N2861A communication module. Warranty options All models include a standard 1-year warranty. Contact your local sales office for prices of extended options: Option number R-51B-001-3C R-51B-001-5C 1-year return-to-agilent warranty, extended to 3-years 1-year return-to-agilent warranty, extended to 5-years 8

Ordering information (continued) Passive probes Product number N2862A N2863A 10070C Current probes Product number N2774A N2775A 1146A 10:1, 150 MHz passive probe (shipped with DSO3062A, DSO3102A, DSO3152A) 10:1, 300 MHz passive probe (shipped with DSO3202A) 1:1, 20MHz passive probe 50 MHz current probe, AC/DC Power supply for N2774A 100 khz current probe, AC/DC To get a Quick Quote on Agilent 3000 Series oscilloscopes, go to www.agilent.com/find/dso3000 Call the measurement experts at Agilent Technologies Whether your work is mostly digital, mostly analog, or somewhere in the middle, our measurement specialists can help you select the best debugging solution. Call today to talk to a knowledgeable engineer about your particular application. High-voltage probes Product number 10076A N2771A 100:1, 4 kv, 250 MHz high-voltage probe 1000:1, 15 kv, 50 MHz high-voltage probe Differential probes Product number 1141A N2772A 200 MHz differential probe. Requires 1142A power supply 600 V CAT III, 20 MHz differential probe. Cables Product number 10833A GPIB cable, 1 m long 9

www.agilent.com Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent T&M Software and Connectivity Agilent's Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 67556 0042 Email: tm_ap@agilent.com Contacts revised: 1/12/05 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2005 Printed in USA May 3, 2005 5989-2235EN