TECHNICAL BULLETIN [ 1 / 5 ]



Similar documents
TECHNICAL BULLETIN. Checking the products and their versions that we have confirmed the operation on Windows 8 and Windows 8.1.

Unpacked BCD Arithmetic. BCD (ASCII) Arithmetic. Where and Why is BCD used? From the SQL Server Manual. Packed BCD, ASCII, Unpacked BCD

BCD (ASCII) Arithmetic. Where and Why is BCD used? Packed BCD, ASCII, Unpacked BCD. BCD Adjustment Instructions AAA. Example

Open Field Network CC-Link Troubleshooting Guide

How to read this guide

Abysssec Research. 1) Advisory information. 2) Vulnerable version

The Next Generation in Industrial Programming Mitsubishi FA Integrated Concept

Important Notes for WinConnect Server ES Software Installation:

MONITORING PERFORMANCE IN WINDOWS 7

Setting/Monitoring Tools for the C Controller Module Version 4 Operating Manual -SW4PVC-CCPU-E

Phoenix Technologies Ltd.

Setup and Programming of the. Master Module R72-11Z-SLSASG-028

Direct Connection to IT Systems. Direct Connection to IT Systems

CONTENTS CONTENTS... A - 1 FURTHER READING REFERENCE LIST...A - 3. CHAPTER 1 INTRODUCTION 1-1 to Database Overview

The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example. Select [Project] [New].

Custom Solutions Center. Users Guide. Low Cost OEM PackML Templates L02 Release. Version LC-1.0

Systems Design & Programming Data Movement Instructions. Intel Assembly

«Как найти 0-day в браузере» Бажанюк

BIOS Update Release Notes

Hands-On Microsoft Windows Server 2008

Understand Performance Monitoring

PC Build and Manual Part 1

SAFETY PRECAUTION. (Always read these instructions before using the products.)

TeamPoS2000-M Windows XP Pro Device Installation

IA-32 Intel Architecture Software Developer s Manual

Monthly Specification Update

Preparing a SQL Server for EmpowerID installation

GE Sensing. SiCalPro. Monitor and control software. User manual - K0452

Important Notes for WinConnect Server VS Software Installation:

Electronic Multi-Measuring Instrument

SMS (Server Management Software) Digital Video Recorder. User s Manual

Electronic Multi-Measuring Instrument

CHAPTER 6 TASK MANAGEMENT

PC computer configurations & Windows optimizations (Updated November 2012)

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

Intel Rapid Start Technology User Guide for UEFI Mode

Mitsubishi Electric Q Series PLC Ladder Monitor. Operation Manual

Hard Drive Installation Options Ontrack Data Recovery Technical Paper.2004

Using Integrated and Discrete Graphics Simultaneously

AMD Processor Recognition Application Note. For Processors Prior to AMD Family 0Fh Processors

Computer Setup User Guide

Installing Hortonworks Sandbox on Hyper-V

Local Playback Software User Manual (V2.0)

Series Gateway functions Manual for GT Works3

1 Intel Smart Connect Technology Installation Guide:

MICROPROCESSOR. Exclusive for IACE Students iacehyd.blogspot.in Ph: /422 Page 1

MCTS Guide to Microsoft Windows 7. Chapter 10 Performance Tuning

Instruction Set Architecture

TeamViewer 9 Manual ITbrain

Intel 810 and 815 Chipset Family Dynamic Video Memory Technology

Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC

64-Bit NASM Notes. Invoking 64-Bit NASM

CW Configurator Operating Manual -SW1DND-RCCPU-E

Nexio G8 SNMP Support

Hardware Compatibility List

Intel 8086 architecture

Software Evaluation Guide for Autodesk 3ds Max 2009* and Enemy Territory: Quake Wars* Render a 3D character while playing a game

USB 2.0 VGA ADAPTER USER MANUAL

Installing the Operating System with Express Setup

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

Introduction. Symbol Script Timeout Setting. Sample MES Custom Code in Symbol Script. Application Versions. Sample Code

High-speed image processing algorithms using MMX hardware

Operating Systems Lab Exercises: WINDOWS 2000/XP Task Manager

Windows 7 XP Mode for HP Business PCs

E2437. Motherboard. Troubleshooting Guide Q & First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved.

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

WinCON8000-R2/R8. Hardware User s Manual

TPM. (Trusted Platform Module) Installation Guide V2.1

Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide

Intel Server Board S3420GPRX Intel Server System SR1630GPRX Intel Server System SR1630HGPRX

Security Policy for FIPS Validation

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

For designers and engineers, Autodesk Product Design Suite Standard provides a foundational 3D design and drafting solution.

PassMark - G3D Mark High End Videocards - Updated 26th of May 2012

Intel Power Gadget 2.0 Monitoring Processor Energy Usage

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

UNISYS. Server Management 2.0. Software Release Announcement. imagine it. done. Server Management 2.0 and Higher. May

================================================================== CONTENTS ==================================================================

TPM. (Trusted Platform Module) Installation Guide V for Windows Vista

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

EMDX3 Multifunction meter Cat No ModbusTable LGR EN v1.01.xls

Hacking the Preboot execution Environment

Freescale Semiconductor, I

Upgrade to Microsoft Windows Server 2012 R2 on Dell PowerEdge Servers Abstract

Using Debug 1 INTRODUCING DEBUG

User Guide USB 2.0 LAPTOP DOCKING STATION WITH VIDEO N2953

SL-8800 HDCP 2.2 and HDCP 1.x Protocol Analyzer for HDMI User Guide

CONNECTING A CLOUD CAMERA TO NCS

User Guide for Windows 10

Data Sheet Graphic Cards for Fujitsu ESPRIMO PCs

Release Bulletin EDI Products 5.2.1

Computer Organization and Architecture

Network Connect Installation and Usage Guide

Intel Desktop Board DG31GL

Connecting and Setting Up Your Laptop Computer

A Tiny Guide to Programming in 32-bit x86 Assembly Language

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM

Transcription:

TECHNICAL BULLETIN [ 1 / 5 ] [Title] Corrective action when MELSOFT products cannot be installed on a personal computer on which the 6th Generation Intel Core Processor has been installed [Date of Issue] June 2016 [Relevant Models] MELSOFT series Thank you for your continued support of Mitsubishi FA software MELSOFT series. This bulletin explains the symptom that MELSOFT products cannot be installed on a personal computer on which the 6th Generation Intel Core Processor has been installed, and its corrective action. 1. SYMPTOM (1) The installation does not start. The following screen that indicates the start of installation does not appear at the start of the installation. (2) The installation stops during the installation. The installation stops if the specific product is selected for installation during the installation.

TECHNICAL BULLETIN [ 2 / 5 ] 2. CONDITIONS 2.1 Specification of a Personal Computer The symptom occurs when the BIOS *1 or UEFI *2 has any problem (chapter 3) on a personal computer that meets following conditions: The 6th Generation Intel Core Processor is installed. The personal computer outputs videos using an on-board video (built into CPU). Microsoft Windows 7 32-bit edition is used. *1 Short for Basic Input/Output System. The BIOS is located on the motherboard and it manages and controls peripheral devices connected to the personal computer. *2 Short for Unified Extensible Firmware Interface. UEFI replaces the BIOS. 2.2 Occurrence Situation in MELSOFT Products Product name iq Works GX Works3 GX Works2 GT Works3 MT Works2 Ver. 1.519R or later Ver. 1.513K or earlier Situation The symptom occurs during installation in the following situation: Installation of GX Developer included in the product is selected on the installation screen. The symptom occurs during installation in any of the following situations: Installation of GX Developer included in the product is selected on the installation screen by following the installation procedure. The setup.exe of GX Developer included in the product is The symptom occurs during installation in the following situation: The setup.exe of GX Developer included in the product is The symptom occurs during installation in any of the following situations: Installation of GX Developer included in the product is selected on the installation screen by following the installation procedure. The setup.exe of GX Developer included in the product is The setup.exe of Configurator-QP included in the product is GX Developer and Configurator-QP are not included in these products. The symptom occurs in any of the following situations: The setup.exe of MES DB Connection Service (for GT Works3) included in the product is The setup.exe of the multimedia data link tool (for GT Works3) included in the product is RT ToolBox2 / RT ToolBox2 mini MR Configurator2 MR Configurator C6 C5 or earlier PX Developer PX Developer Monitor Tool MX Component

TECHNICAL BULLETIN [ 3 / 5 ] Product name MX Sheet MX MESInterface-R MX MESInterface GX LogViewer CPU Module Logging Configuration Tool MELSEC iq-r series High Speed Data Logger Module Tool High Speed Data Logger Module Tool High Speed Data Communication Module Tool BOX Data Logger Configuration Tool QnH to QnU conversion support tool GX Developer A/QnA to Q conversion support tool GX Configurator-AD GX Configurator-DA GX Configurator-CT GX Configurator-TC GX Configurator-TI GX Configurator-FL GX Configurator-PT GX Configurator-AS GX Configurator-SC GX Configurator-QP GX Configurator-AP GX Simulator GX Converter Situation The symptom occurs in the following situation: The installation of DB Connection Service and DB Connection Service Setting Tool are The symptom occurs in any of the following situations: The installation of MES Interface Function Configuration Tool is The installation of DB Connection Service and DB Connection Service Setting Tool are CC-Link system master/local CC-Link IE Controller Network 1.18U or later 1.17T or earlier 1.20W or later 1.19V or earlier CC-Link IE Field Network MELSECNET/H 29F or later 28E or earlier

TECHNICAL BULLETIN [ 4 / 5 ] 3. CAUSE The symptom occurs due to the abnormal behavior of ntvdm.exe, the Windows system module. We have found that this is caused by a defect in the BIOS or UEFI on the personal computer. 3.1 Investigation Result As a result of our investigation, we found that the ntvdm.exe loops infinitely. (1) Analysis result The following explains the result of analysis. The addresses differ depending on the manufacturer of the personal computer. Analysis result of ntvdm.exe 0:000> r eax=0004ffff ebx=00000200 ecx=00000000 edx=00000000 esi=00042000 edi=00000070 eip=0000f18e esp=000006cc ebp=000006dc iopl=0 vif nv up ei pl zr na pe nc cs=c000 ss=0000 ds=0000 es=0070 fs=0000 gs=0000 efl=000a0246 c000:f18e ebfe jmp F18E 0:000> ub c000:f18e c000:f177 66be00200400 mov esi,42000h c000:f17d e8ba7c call 6E3A Call the subroutine c000:f180 66a900000004 test eax,4000000h Check the returned value c000:f186 7502 jne F18A Jump if the flag of 0x4000000 is not set c000:f188 eb03 jmp F18D Jump if the program above does not jump c000:f18a f9 stc c000:f18b eb03 jmp F190 c000:f18d f8 clc Reset the carry flag c000:f18e ebfe jmp F18E Infinite loop (2) Conclusion The address that goes into the infinite loop may be processed by the BIOS or UEFI option. The problem may occur in the BIOS or UEFI of the graphic function.

TECHNICAL BULLETIN [ 5 / 5 ] 3.2 How to Check the Operation of "ntvdm.exe" The operation can be checked by following the procedure below. 1. Right-click the taskbar of Windows, and then click [Start Task Manager]. 2. Select the "Performance" tab in the Windows Task Manager. 3. Check the number of graphs (number of cores) in "CPU Usage History". Example) Number of cores is '4' 4. Select the "Processes" tab in the Windows Task Manager. 5. Check the value in "CPU" of "ntvdm.exe". Example) CPU usage of one core is '25' 6. Calculate the CPU usage by multiplying the values which have been obtained in Step 3 and Step 5. If the CPU usage is around 100%, it indicates that the error is caused by a high-load processing of the ntvdm.exe. 4. CORRECTIVE ACTION We have concluded that the MELSOFT products can be installed correctly by modifying the BIOS or UEFI. If the symptom occurred, please contact the manufacturer of the personal computer used with this bulletin attached. Obtain the appropriate BIOS or UEFI for your personal computer. TRADEMARK Intel is either registered trademarks or trademarks of Intel Corporation in the United States and/or other countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. The company names, system names and product names mentioned in this manual are either registered trademarks or trademarks of their respective companies. In some cases, trademark symbols such as ' ' or ' ' are not specified in this manual.