Sheet A-1 SHEET A-1 Football Roof Plan 5 LaCross Roof Plan 5 88' 87' SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 2 Roof Plan
Sheet A-2 Hockey Roof Plan Baseball Roof Plan SHEET A-1 SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 1 Roof Plan
Sheet A- 1 DRIP EDGE DETAIL CM 150SL PANEL 10-1 x 1" PHW (12" o.c.) (FIELD APPLIED BETWEEN PANEL RIBS) FIELD CUT & HEM PANEL 180ᄚ DRIP EDGE FLASHING 10-1 x 1" PHW (5 PER/ PANEL) 1/8" - POP RIVET (6" o.c.) CLEAT FLASHING Z-CLOSURE STANDING SEAM PANEL FASTENERS (BY OTHERS) COUNTER FLASHING RAKEWALL FLASHING PLYWOOD SUBSTRATE (1/2" MIN.) Z-CLOSURE FLASHING 1/8" - POP RIVET (18" o.c.) 10-1 x 1" PHW (12" o.c.) CM 150SL PANEL (FIELD CUT AND BEND) 11700 Pierson Rd. Wellington, FL. 1 12-1 x 1 1/2" DP SD (12" o.c.) FLOATING RAKE ANGLE 10-1 x 1" PHW (12" o.c.) NOT TO BE TIGHTENED ON MODULE 2 FLOATING RAKEWALL
10-1x1" PHW (5 PER PANEL) FLUSH CUT ZEE CLOSURE TO BE INSTALLED BETWEEN PANE RIBS w/ TUBE SEALANT AT SIDES AND IN ANY VOIDS RIDGE HIP CM 150SL PANEL 1/8" - POP RIVET (18" o.c.) Z-CLOSURE FLASHING RIDGE / HIP FLASHING BOX END OF PANEL (SEE ZEE CLOSURE OPTIONS DETAIL) 10-1 x 1" PHW (5 PER PANEL) PLYWOOD SUBSTRATE (1/2" MIN.) FASTENERS (BY OTHERS) REGLET FLASHING BOX END OF PANEL (SEE ZEE CLOSURE OPTIONS DETAIL) HEADWALL FLASHING 10-1 x 1" PHW (5 PER PANEL) Z-CLOSURE FLASHING 1/8" - POP RIVET (18" o.c.) CM 150SL PANEL PLYWOOD SUBSTRATE (1/2" MIN.) 10-1x1" PHW (5 PER PANEL) Sheet A- 11700 Pierson Rd. Wellington, FL. 1 OPTION 1 OPTION 2 FLUSH CUT ZEE CLOSURE TO BE INSTALLED BETWEEN PANE RIBS w/ TUBE SEALANT AT SIDES AND IN ANY VOIDS HEADWALL DETAIL
Section 1 Sheet A-1 1 5 Section 2 6 2 Section Section SHEET A-1 Roof Plan 1 Roof Curb Detal 2 Through Wall Scupper Metal Coping Detail Vent Pipe Detail SHEET A- 5 Drain Detal 6 Wall Detail 7 Curb Detail Village Park Gym Westside Roof Plan 11700 Pierson Rd, Wellington, FL Date: 05-29-15 Metal Deck Site Map 1 2 Granulated Modified Roof Area
Gaskets fasteners 6" o. c. Fasteners approximately 8" {200 mm} O.C. Removable sheet metal counterflashing Extended field plies above head of cant Cant Roof Deck Wood Nailers & Metal Curbs Multiple Ply Modified Membrane Base Flashing (8"{200 mm} Min. Height) Feathered at field of roof Multiple Modified Roof Membrane rigid insulation 1 ROOF CURB DETAIL 2 THROUGH WALL SCUPPER Sheet metal parapet cap with continuous cleat sloped to drain roof side Extended base flashing over top of parapet wall Gasketed fasteners 12" o.c. Continuous shim (optional) Fasteners approx 8" (200 mm) O.C. Vent Pipe- Area in Contact with Membrane Must Be Primed Modified Membrane Flashing Ply First Membrane Flashing Ply Through Wall Metal Scupper with Fasteners Prime Metal and Set in roof cement Granule Embedment Field Cap Membrane Ply Field Base Membrane Ply Decking / Insulation (Min. 1" thick) Concrete Primer 8" Min. Flashing Piece Modified Membrane Village Park Gymnasium 11700 Pierson Road Wellington, Florida Date: 5-26-15 Wood nailer Prime surface as required Collar Piece (With Finger Cuts) Extended field plies above head of cant Multiple-ply modified membrane base flashing feathered at field of roof VENT PIPE FLASHING Multiple-ply Modified Bitumen roof membrane Cant Roof deck Rigid Roof Insulation METAL PARAPET CAP (COPING) AND BASE FLASHING
WALL (prime masonry surfaces) Sheet A- Dynaweld 180 S (mechanically attach) COUNTERFLASHING (compression fit) Dynaweld 180 Cap FR LEAD FLASHING ( lb., 0" X 0" prime and set in mastic) CLAMPING RING Dynalastic 180 Cap FR MASTIC (PA-1021 Plastic Cement in shaded area) Dynaweld 180 S LEAD FLASHING STRAINER & CLAMPING RING (prime and set in mastic) 2" Rigid insulation over metal deck 8" min. " 5 DRAIN DETAIL 6 COUNTERFLASHING (compression fit) WALL DETAIL Modified Cap Flashing Modified Base Flashing NON - COMBUSTIBLE CANT Modified Cap Sheet Modified Base sheet " 1" LIGHT WEIGHT OVER METAL DECK Village Park Gymnasium Roof Details 11700 Pierson Road Wellingon, Florida Date: 5-26-15 Dynaweld 180 Cap FR Dynaweld 180 S 1" " 8" min. NON - COMBUSTIBLE CANT Dynaweld 180 Cap FR SLOTTED METAL DECK ZIC LIGHTWEIGHT INSULATING CONCRETE SYSTEM 7 HVAC CURB FLASHING DETAIL