TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012



Similar documents
Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Intelligent Cable Management Systems

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

Specifications for Communication Cabling Distribution Systems

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Building Telecommunications Infrastructure Requirements

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Element D Services Heating, Ventilating, and Air Conditioning

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

The Telecommunications Closet and Building Services

SECTION TELECOMMUNICATION ROOMS

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

UT Southwestern Medical Center Information Resources Cable Installation Standard

4 Installation Requirements

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

Telecommunications Infrastructure Standard for Data Centers Tutorial

TELECOMMUNICATIONS NETWORK STANDARDS AND GUIDELINES FOR THE NEW ADMINISTRATION BULDING

800 Communications Circuits

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

TIA-942 Data Centre Standards Overview WHITE PAPER

TIA-942: Data Center Standards

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Cabinets 101: Configuring A Network Or Server Cabinet

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Enclosure and Airflow Management Solution

Purpose of the ANSI/TIA/EIA-569-A Standard

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Structured and Point to Point Network Cabling for Industrial Automation

TCTC Cabling Specifications

Healthcare. Carol Everett Oliver, RCDD, ESS. Berk-Tek, a Nexans Company

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Network Design. Yiannos Mylonas

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ADC-APC Integrated Cisco Data Center Solutions

APC APPLICATION NOTE #112

University of St Andrews. Energy Efficient Data Centre Cooling

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Data Center Cabling Design Trends

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)

Organizing and Managing Equipment Rooms

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Specifying an IT Cabling System

BICSI NxtGEN & Global Data Center Standards Update

APC APPLICATION NOTE #92

Session 14 Cable Support Systems

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

Standards and Guidelines for Telecommunications Wiring Design and Installation Montana State University-Bozeman

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

Benefits of. Air Flow Management. Data Center

Errata NFPA 70. Proposed 2014 Edition

PUBLIC RESTROOMS, DESIGN INTENT

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

Small Data / Telecommunications Room on Slab Floor

Great Lakes Data Room Case Study

InstaPATCH Cu Cabling Solutions for Data Centers

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Healthcare Infrastructure. Planning. Standards Compliance & Best Practices. J M t Jose Mozota National Sales Manager Legrand Data Communications

What is a Datacenter?

with Component Rating A Simple Perspective

IT&T Infrastructure Standards

Electrical Code (NEC) Snake Tray Cable Management Solutions

Data Center Components Overview

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

3.0 DFCM REQUIREMENTS 3.6 ELECTRICAL. PART 2: Communications and Security Wiring Systems DFCM DESIGN MANUAL UNIVERSITY OF UTAH SUPPLEMENT

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

Structured Cabling Statement of Work

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Building Code Clarifications - 7. Fire Resistance

SECTION COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

Data center upgrade proposal. (phase one)

Transcription:

TIA 569 Standards Update Pathways & Spaces Ignacio Diaz, RCDD April 25, 2012

The purpose of this Standard is to standardize specific pathway and space design and construction practices in support of telecommunications media and equipment within buildings. Scope limited to telecommunications aspect of building design but influences design of other building services (i.e. HVAC, electrical power, etc) Define requirements for key spaces Building Spaces Access & Service Provider Spaces Multi tenant Building Spaces Building Pathways Cabling distribution should try to find a solution that will: Cabling distribution should try to find a solution that will: Accommodate cabling changes Minimize occupant disruption when horizontal pathways are accessed Allow for future growth

A standard established for rooms, pathways, and areas into and through which structured cabling, components, and equipment are installed. Appliesto: Conduits Under floor ducts and Floor Boxes Access floor (Raised Floors) Ceiling pathways (J Hooks & Rings) Cable tray systems Perimeter pathways Raceways Telecommunications Closet & Equipment Room Sizes & Provisions

Building Spaces: General Requirements General Requirements apply to Distributor Room Common Distributor Room Entrance Room Access Provider Space Service Provider Space Temperature & humidity guidelines per ASHRAE Thermal Guidelines for Data Processing Environments Temperature & humidity in telecommunications i space shall hllmeet requirements for ASHRAE Class 3 UPS larger than 100kVA located in separate room Bonding & grounding system shall be provided per ANSI/TIA 607 B

Building Spaces: General Requirements Plywood backboard ¾ in plywood (at least one wall) Painted with two coats fire retardant paint No longer required to be painted white Ceilings Ceiling height min, 8 ft clear space (10ft between finished floor and lowest point of ceiling) Recommend for max flexibility not to use suspended ceiling Floor loading Static & dynamic capacity shall be sufficient to bear both distributed & concentrated loads Shall consult structural engineer Lighting Min 500 lux in horizontal plane Min 200 lux in vertical plane Measured 1 m (3 ft) above finished floor Powered separately from telecommunications equipment Should not use dimmer switches Doors Minimum of 36 x 80 (optional 72 x 90 )

Building Spaces: Distributor Room Common access for cabling subsystems & building pathways Contains telecommunications equipment, cable terminations, & cross connect In a commercial building it is called an equipment room or telecommunications room depending on what isin in it Should follow general guidelines Multiple distributor rooms on same floor interconnected by minimum of one metric designator 78 (trade size 3) conduit or equivalent pathway

Building Spaces: Distributor Room Distributor B (i.e. intermediate cross connect (IC) in commercial building) min. of 10 m 2 (100 ft 2 ) Distributor C (i.e. MC in commercial building) min. 12 m 2 (120 ft 2 ) for building with gross area up to 50,000 m 2 (500,000 ft 2 ) Increase 1 m 2 (10 ft 2 ) per 10,000000 m 2 (100,000000 ft 2 ) increase in building size Minimum 1 distributor room per floor Minimum two dedicated 120 VAC /20A outlets 6 ft spacing; 6 in above floor

Building Spaces: Entrance Room / Space Entrance Room /Space Entrance for outside plant & pathways shall meet requirements of ANSI/TIA 758 B (Outside Plant ) standard In buildings up to 10,000 sq m (100,000 sq ft), wall mounting terminating hardware may be suitable Minimum of two dedicated 120 VAC /20 A outlets Distributor Enclosure Centrally located Lighting, measured in distributor enclosure, minimum 500 lux Minimum of one dedicated 120 VAC /20 A outlet

Access & Service Provider Spaces Used for the location of transmission, reception, and support equipment Minimum Access & Service Provider Space :1.5 m x 2 m (4ft x 6 ft) Should be close to Distributor C (i.e. MC) At least one dedicated 120 VAC/20 A, non switched duplex electrical receptacle for equipment

TIA 569 Pathways & Spaces Standard Building Spaces: Racks & Cabinets Minimum 3 ft front clearance; 4 ft is preferable Minimum Minimum 2 ft rear clearance; 3 ft is preferable 2 ft rear clearance; 3 ft is preferable Equipment may require additional clearance Suggest using cabinets 6 in deeper or wider than l largest equipment i Should have adjustable mounting rails Rails should have markings Rails should have markings

TIA 569 Pathways & Spaces Standard Building Spaces: Racks & Cabinets Cabinets shall be selected & configured to provide adequate cooling (some suggestions listed below) Forced airflow using fans g Natural airflow between hot & cold aisles Hot aisle/cold aisle cabinet arrangement Use of blanking panels and baffles Sealing air leaks around cable ingress points Sealing air leaks around cable ingress points Vertical cable manager shall be installed between racks and at both ends of every row (at least 3.25 in wide) Horizontal management sufficient to provide strategic growth of up to 100% but not impair cooling

Building Pathways Consider quantity, size & bend radius requirements of cable when determining size of pathway Allow for growth Not tlocated din elevator shafts hft Areas above ceilings may be used as pathway for telecommunications cables & for connecting hardware Co installation of telecommunications cable & typical branch circuit (120/240 VAC/ 20A) must meet requirements of NFPA 70

Building Pathways Zero pathway separation permitted when telecommunications cables & power cables both enclosed in metallic pathways (min wall thickness of 1 mm (0,04 in) of steel or 1.5 mm (0,06 in)aluminum) Provides table with guidelines for separation of telecommunications pathways for balanced twisted pair cabling from adjacent power wiring Balanced TP cabling separated from fluorescent lamps/fixtures by minimum of 125 mm (5 in)

Building Pathways Pathway separation from sources of electromagnetic energy: Condition <2KVA 2-5KVA >5KVA Unshielded Power Lines in proximity to open PVC Pathways 5 in 12 in 24 in Unshielded Power Lines 2.5 6 in 12 in in proximity to Grounded in Metallic Pathways Power Lines enclosed in Metal Grounded Pathways <1 in 3 in 6 in in proximity to Grounded Metallic Pathways

Building Pathways Minimum 75 mm (3 in) clear vertical space available above ceiling tiles if using as pathway Min. 300 mm (12 in) clearance above cable tray system or runway Trays may be divided with barrier for physical separation between power & TP cable Non continuous supports located at intervals not to pp exceed 1.5 m (5 ft)

Building Pathways Cable Trays Planned for initial max calculated fill ratio of 25% Note: A calculated fill ratio of 50% for 4 pair & similar cable will physically fill entire tray due to spaces between cables Cable Runway Stacked no higher than 150 mm (6 in) Pathways free from burrs, sharp edges or projections Trays and wireways may be divided with a barrier to allow for physical separation of different types of services. If nonmetallic trays and wireways are located in the plenum, they shall be plenum rated.

Building Pathways Ceiling Pathway (J Hooks & Bridle Rings) Spacing 48 to 60 off center (eliminate copper degradation) Maximum of Q(75) 4Pair UTP Over Q(75) add another J Hook or migrate to Cable Tray

Building Pathways Conduit Sections between pull points shall not exceed 30 m (100 ft) in runs that total more than 30m (100 ), insert pull boxes so that no segment between pull points exceeds the 30m (100 ) limit. No section shall contain more than two 90 degree bends Conduits with internal diameter of 50 mm (2 in) or less, inside bend radius of a bend in conduit shall be at least 6 times the internal diameter Conduits with an internal diameter of more than 50 mm (2 in), the inside radius of a bend in conduit shall be at least 10 times the internal diameter. Bonded to ground, in accordance to national or local requirements Has reference table for pull box sizes Maximum fllf fill for furniture pathways is 40%

Building Pathways Conduit (RIGID, EMT, ENT, PVC, HDPE) Must be a minimum of 3/4 40% Fill Ratio (NEC) applies Fire Codes apply and must be respected regarding the use of polymers

Pull Boxes and Splices Pull Box Installation Locate pull boxes in easily accessible locations. Horizontal cable boxes should be installed above suspended ceilings. Should be used when installing a pull string or cable, fishing the conduit s run, and pulling and looping the cable in the next length of conduit. Pull boxes should be used when: Conduits runs are more than 30m (100 ) Contain more than two 90º bends. Pull P boxes shall not be used for splicing cable. Splice boxes Intended to be used for splicing in addition to pulling cable. A slip sleeve is a conduit sleeve that is larger than the main conduit, and slipped over an opening in a conduit run after the cable is in place. A gutter is a square, sheet-metal housing, which is placed over an opening in a conduit. Slip sleeves or gutters cannot be used for splices, but can be used in place of a pull box, are more economical to install, and will provide more space for pulling.

Other Pathway Types Power pole specifications Power poles standard sizes accommodate 3m (10 ), 3.7m (12 ), and 4.6m (15 ) ceiling heights. Power pole installation Mount rigidly between the ceiling support channel grid and carpeted or tiled floor. Utility columns may be attached to the cross rails only if the rails are securely anchored to the main ceiling support channel. Poke thru specification Poke thru distribution is usually implemented by installing cable from the ceiling of the floor below, to a point where service is desired on that same floor, then poking thru the floor to allow the cable to be attached to telecommunications device. Poke thru installation Poke thru installation should be done in accordance to all local and national codes, in strict accordance with the Underwriters Laboratories procedures found in the Fire Resistance Directory, and the poke thru addendum 4 to ANSI/TIA/EIA 569 A.

Building Pathways The NEC and local codes take precedence when installing conduit, choices in conduit type shall be ofthe type permitted under the appropriate electrical codes.

Backbone Backbone pathways consist of: Interbuilding backbone pathways which extend between buildings Intrabuilding backbone pathwayswhichwhich are contained within a building

Backbone Intrabuilding pathways consist of: Ceiling pathways Conduits Sleeves Slots Trays

Backbone Slots Sleeves Trays

Backbone Sleeves An opening, usually circular, through the wall, ceiling, or floor to allow the passage of cables and wires. Slots An opening through a wall, floor, or ceiling, usually rectangular, to allow the passage of cables and wires.

Firestopping

New Version! New revision work has been going on for past year Reference for all premise standards No longer specific to commercial buildings New revision ii just approved for publication as ANSI/TIA 569 C Other Changes include Removed 60% fill max limit for furniture pathways for growth; only recommends initially designing to 40% fill Power & noise separation apply to all applications; no new recommendations dti for 10Gb/s applications

Accommodating New ASHRAE Guidelines TIA 569 C draft was almost complete when ASHRAE changed guidelines Two phase approach to including changes 1. Added new class names editoriallyto TIA 569 C No change to requirements for TIA 569 C 2. Working on addendum to harmonize Will be TIA 569 C C.1 May be complete by end of year 29

ASHRAE changes to Thermal Guidelines for Data Processing Environments Class 1 & 2 now A1 & A2 Two new classes, A3 & A4 A1, A2, A3 & A4 have allowable & recommended ranges No change with A1 & A2 Expanded dallowable range for A3 & A4 Class 3 & 4 replaced by Class B & C with no changes 30

TIA 569 Pathways & Spaces Standard ASHRAE changes to Thermal Guidelines for Data Processing Environments

Other Standards and TIA 569 Because ANSI/TIA-569-C is now a generic reference for pathways, specific requirements unique to an application will be specified in the application standard. For example, specific pathway and spaces requirements for commercial buildings will be specified in ANSI/TIA-568-C.1. Specific pathway and spaces requirements for healthcare facilities will be specified in ANSI/TIA-1179. Let s take a look! 32

TIA 1179 Healthcare Facilities Standard Healthcare vs. Premises Broader scope of application specific IP devices Sensitive installation environment Larger pathways Larger Telecom Rooms Greater Workstation densities

TIA 1179 Healthcare Facilities Standard Unique Cabling Challenges Redundant and high density pathways (conduits, cable tray) High levels of EMI, high temperature, chemicals and gasses maybe present Cable selection dependent on attributes to comply with atmospheric conditions Cable selection affects pathways Application specific, high termination work area densities Stringent codes and regulations

TIA 1179 Healthcare Facilities Standard Pathway Guidelines Pth Pathways should not compromise operation of the facility Enclosed pathway systems in air handling spaces to meet Infection Control lrequirements (ICR) Segregation of cables for different networks & applications (due to safety ft protocols)

TIA 1179 Healthcare Facilities Standard Et Entrance Facilities (EF) &E Equipment tr Rooms (ER) Route diversity two separate pathways from the entrance facility to the equipment room Demarcationpoint of outside access providersmaybe determined by federal or local regulations. Accommodation of other systems may increase size (BAS, nurse call, security, CATV, biomedical systems) Twice the size of a data/telecommunications closet (allowing for future double growth rate)

TIA 1179 Healthcare Facilities Standard Telecommunications Rooms (TR) andtelecom Enclosures (TE) Non telecommunications services (i.e. gasses, fluids) not allowed Larger TR than office building 12m 2 (130 ft 2 ) or larger TE serves smaller floor area or where TR is not allowed (be aware of exposure of magnetic fields, radiation, chemicals, etc)