Educational solutions. MV/LV power grid design and operation laboratory



Similar documents
Off-grid solar and backup power installations

Seize the benefits of green energy and the smart grid

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

Delivering a world-class monitoring service for you and your customers. OptiM2M application for remote monitoring of machines

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

Virtual Power Plant solution for energy suppliers. Immediate, reliable access to distributed energy resources

UPS system for emergency lighting and smoke extraction

Solutions for Photovoltaic Systems. Large buildings and power plants

Management of electric vehicle fleet charging

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

StruxureWare Power Monitoring Expert Data Center Edition. Power system intelligence and reliability for your entire infrastructure

Technical Requirements for Renewable Energy Systems Connected to the Low Voltage (LV) Network via Inverters

An Alternative Approach to Improving SAIDI and SAIFI Indicators

StruxureWare Power Monitoring Expert 7.2

De Jaeger, Emmanuel ; Du Bois, Arnaud ; Martin, Benoît. Document type : Communication à un colloque (Conference Paper)

PowerGem Pro Uninterruptible Power Supply

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

7. Reactive energy compensation

Easily connect your switchboards to facility management solutions

IEC & 2 standard. The reference for safe and reliable LV switchboards

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

High-Megawatt Converter Technology Workshop for Coal-Gas Based Fuel Cell Power Plants January 24, 2007 at NIST

Magnus Callavik, ABB Power Systems, HVDC, Västerås, Sweden Phone: +46(0)

How To Understand The Electrical Power Supply Of A Power Supply System

Mics KERYS FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS KER/GB-2004/1

The Different Types of UPS Systems

The Different Types of UPS Systems

Educational solutions

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Current Cost TREC Current Cost ENVI Current Cost EnviR SmartNow Solar Monitoring Kit

Jemena Electricity Networks (VIC) Ltd - Network Tariffs For The 2015 Calendar Year (Exclusive of GST)

Power products and systems. Intelligent solutions for power distribution Zone concept

13. Electrical network design methodology and application example

Size template. Grid Connection Masterclass Energex John Lansley Senior Network Solutions Engineer

SoMove Setup software

MV vacuum circuit breaker Evolis. When trust guides your steps

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

40 Years of experience in EMC testing

Product Environmental Profile Step Down Transformers

Achieve your career potential. Discover the Acorn Emerging Leaders Programme at Schneider Electric

Electrical Network Management System

Rugged and open to your applications

Electricity Meter in the age of Photovoltaic

Delta Transportation Automation Solution.

PSS SINCAL - Overview -

Low Voltage Transformers Sealed, General Purpose, Dry Type

Numerical Differential Protection

PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY

Product Overview L offre Produits

Data Center Integrated solutions

Achieve energy efficiency without sacrificing performance. Solutions for water treatment plants and pumping stations

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

Grid Connected Storage Various Applications Realised with Proven Technologies. Wilhelm van Butselaar Clean Energy Week 2013, Brisbane July 2013

Committee on the Northern Territory s Energy Future. Electricity Pricing Options. Submission from Power and Water Corporation

Analysis of the Brazilian Data Center Power Supplies Market

Layman s Report Greencity

StruxureWare Power Monitoring 7.0.1

Backup Recovery User Manual

Energy Storage System Performance Testing

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

Modernize your Monitor Pro software with less risk, less cost and less effort

TX 2C/RX 2C TOY CAR REMOTE CONTROLLER WITH FIVE FUNCTIONS

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

North Street, Stoke-on-Trent, ST4 7SA. Tel: Fax: Web:

Electrical Systems. <Presenter>

Connecting to the network information pack Version 2

F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Clean and compact drive for energy savings. Altivar 1100 Medium-voltage variable speed drive 0.3 to 10 MW. DIA2ED EN.indd 1 22/07/09 11:36:14

SA Power Networks Network Tariffs - Residential APPLIES TO USAGE FROM 1 JULY 2015

Industrial Communication Whitepaper. Principles of EtherNet/IP Communication

Power Meter Series 700

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

Power factor correction. An introduction to technology and techniques

SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES

Investor Day. Group Strategy. Jean-Pascal Tricoire Chairman & CEO. February 20, 2014

Estimation of electrical losses in Network Rail Electrification Systems

For queries re. this dossier: Erny Huberty, Head of Corporate Marketing, Enovos Luxembourg S.A., (+352) ,

Release: 1. UEE62111 Advanced Diploma of Engineering Technology - Electrical

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

HIGH VOLTAGE SHORE CONNECTION

Transcription:

Educational solutions MV/LV power grid design and operation laboratory

Presentation Context A growing development of the power supply requires a staff competent in its engineering, operation and maintenance. To respond to this demand, Schneider Electric, a global energy management specialist, developed educational equipment entirely corresponding to the MV/LV power supply. Shared resources training centre - The concept of shared resources in electrical engineering is particularly fitted to respond to the needs of both initial and professional training for industrial workers. - Such a centre promotes the collaboration between Schools and Enterprises, giving priority to the following synergy points: - Enterprises need to maintain and develop their resources on specific materials. It is a great place to favour technological watch in the professional sector. - Schools need to introduce an educational method of facing a real situation in industrial projects. The opening towards enterprises makes schools progress in their double mission to train and integrate students in the professional life. Target skills - To identify and test the purpose of different equipments - To operate equipment under load respecting the safety rules - To adjust protective devices - To implement an uninterrupted power supply - To identify different diagrams of earthing system - To maintain and operate an installation - To define and draft the procedures of commissioning, operation and maintenance of a delivery station - To draft test and intervention reports - To diagnose a failure in a MV/LV delivery station - To receive or take courses of renewing the electrical accreditation in order to operate safely Institutions concerned The laboratory responds to the requirements of students of vocational technical schools and the Bachelor of Science in Electrical Engineering. In the professional training, the firms search for specialized trainers and specific equipments.

Presentation of our offer The laboratory of power supply that we propose has for a prototype the installation of a hospital. It represents an advantage of demonstrating the essential features of the power supply. Students will study on an installation of 500 KVA: The concept of supply loop on the power grid The point of operating different earthing systems for reasons of the power supply continuity The implementation of different systems of power backup The design of an installation on a remote site The importance of having an excellent level of maintenance The power in a hospital is supplied by a transforming station which distributes energy in two buildings situated at 300 m from each other: The first represents the building of reception and medical services with a high need for the energy continuity. The second corresponds to the administrative building with a low need for power supply continuity. Our laboratory offers studying the power backup station and the delivery stations of both administrative and medical services buildings. Other educational equipments complete this installation to explore all specificities of the profession. The power grid supply cell Distance between the buildings = 300 m The power-sensitive cell Operating rooms: sensible area: need for a clean signal and no power failure by means of an inverter. Computer rooms: priority area: in case of a power failure, this area is powered by a generating set. Sick rooms: non-priority area: in case of a power failure, this area is no longer powered. Building 1: medical services centre (operating, computer and sick rooms) Operating rooms Local computeur Rooms The ordinary power supply cell Offices: non-priority area: in case of a power failure, this area is no longer powered. Building 2 : administrative centre (offices) Office

Educational offers Presentation of our MV/LV offer The core of the MV/LV power supply offer is situated in the first two rooms. Students work there on a real low power installation. In addition to the basic equipments, we also offer a variety of subsystems and components to make some of these technologies more attractive and didactic. Building 1: medical services centre (high level of service required) High-voltage loops Switch cell Power supply HV counter cell Protection cell Hight voltage cells Inverter Operating rooms, a sensible area Transformer protection Transformer LV switchboard Computer rooms, a priority area HV starter Generating set Sick rooms, a non-priority area Distance between two buildings: 300 m Dry-type transformer IT neutral LV switchboard Building 2: administrative centre (low level of service required) HV sheath of flow Power supply Transformer protection Transformer Lv switchboard Offices (a non-priority area) HV cells Oil-immersed transformer TN neutral LV switchboard

Presentation of our complementary offer In the third room there is a complete range of training benches which enable to master the issues encountered in the power supply system and on an electrical installation. It covers the fields related to: Design Power quality and energy continuity Optimization of consumption Operation and maintenance Electrical safety (protection and electrical accreditation) The proposed educational equipments and measuring tools are designed to let students work in pairs. A detailed technical data sheet is provided as well as a manual with practical exercises drawn up by the professors of the French Ministry of Education. Earthing diagram (ED) benches Protection discrimination bench LV power accreditation system (Habilis) Residential and small service industry pack offer The training bench of management of public lighting (Didalub) Reactive energy compensation training bench Electrical network interference bench (Harmocem) Harmonics interference installation (Min-Harmotris) 3-phase network h a r m o n i c interference bench (Harmotris)

Laboratories for studying power supply

Laboratories for studying power supply

> Need more information? A website to inform you www.schneider-electric.com rubric «products and services» then«educational equipments» Contact : fr-didactic@schneider-electric.com Schneider Electric France Division Opérationnelle Enseignement Technique et Supérieur 35 rue Joseph Monier CS 30323 92506 Rueil-Malmaison Cedex