Photovoltaic System Overcurrent Protection



Similar documents
Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection

Your Sharp system will be supplied with one of the following sets of panels:

Safe, Simple & Complete Solutions for Renewable Energy

BB800 Off-Grid Solar System

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

YSmart Technology Co.,Ltd

PREMIUM CLASS PHOTOVOLTAICS

DC Combiner box and AC solutions. Leadership in circuit protection

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Application Note: String sizing Conext CL Series

British BS 88 Fuses. Introduction

High Speed Fuses. High Speed Fuses

Doe Residence kw DC Roof Mounted Photovoltaic System

Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ANALYSIS 2: Photovoltaic Glass Replacement

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Three-phase monitoring relay CM-PFE

Solar Solutions and Large PV Power Plants. Oscar Araujo Business Development Director - Americas

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

BETA Protecting SITOR Semiconductor Fuses

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

How To Plan Out An Array Of Solar Panels

Photovoltaic Solar Energy Unit EESFB

ABB Inc. April 19, 2011 Slide 1

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Stand Alone PV System Sizing Worksheet (example)

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Tmax MCCBs. Molded case circuit breakers. Tmax

Power Supplies 3. SDN-P DIN Rail Series

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Solar Water Heating and Photovoltaic Electrical Systems Installed on One or Two Family Dwellings

RELAYS Solar Energy Systems

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Free electricity for your home, offices or factory with solar PV panels

Solar Photovoltaic (PV) Systems

We're with you... solar. Call today FOR THE LIFE OF THE SYSTEM YEAR WARRANTY * YEAR OLD BACKED BY CSR BRADFORD CSR A AUSTRALIAN COMPANY

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

ST Series POWER SUPPLIES USER INSTRUCTIONS

Battery Backup for Grid-Tied PV Systems

NH DIN Dual Indication Fuse Links Class gg/gl, 690Vac, 2 to 800 Amps, Sizes 000 to 4 NH Series

ISO 9001 : 2000 certified Copyright 2008 All rights are reserved

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Safety and Installation Instructions for AC Modules

Additional Solar System Information and Resources

Actuator-Sensor-Interface

ABB central inverters PVS to 1000 kw

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Relés e Contatores de Estado Sólido SIRIUS

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SOLAR ChARge CONTROLLeRS

ADDENDUM #1(BID PACKAGE # 3)

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Design of a Photovoltaic Data Monitoring System and Performance Analysis of the 56 kw the Murdoch University Library Photovoltaic System

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April


PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

wietap wietap Overvoltage Protection Tensions running high

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

INSTALLATION MANUAL FOR KYOCERA PV MODULES

3-phase, bidirectional energy meter

Cable Plug acc. to DIN EN , Form A

Inverter / Charger Installation General Operations and AC and DC Connections

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

CompactLogix Power Supplies Specifications

is then retained absolutely without interruption.

Photovoltaic Systems II EE 446/646

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

ROOFER.CO.NZ SOLAR-RIB PHOTO-VOLTAIC LAMINATE

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Technical catalogue. Modular DIN rail components Installation contactors

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Safety technique. Emergency stop module BO 5988 safemaster

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Solar Energy Systems. Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University

Power Distribution & Terminal Blocks

IXOLAR TM High Efficiency SolarMD.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

Transcription:

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and adaptive technology. This technology is improving as solar cells increase in efficiency and modules attain better aesthetic appearance. As a result, solar power is gaining more acceptance and is becoming an increasingly cost-effective and clean alternative to conventional energy sources. A number of PV panels in series is termed a string A number of strings in parallel is termed an array Photovoltaic Protection System from Cooper Bussmann As the installations and demand for PV systems increases so does the need for effective electrical protection. PV systems, as with all electrical power systems, must have appropriate overcurrent protection for equipment and conductors. Cooper Bussmann (the world leader in overcurrent protection products) has developed a revolutionary new fuse link for protecting photovoltaic systems. This development was implemented through coordinated research and testing with leading Solar Panel/Solar System manufacturers. 2 2009 Cooper Bussmann

How Solar Power Systems work Solar Power generation systems are made of Photovoltaic cells and Power inverters. The photovoltaic cells utilise the power of sunlight to converters photons to clean DC (Direct Current) electricity. The Electricity generated by the Solar Cells is then fed into a Power Inverter (PV inverter) that converts and regulates the DC source into usable AC power. The AC power can then be used locally for specific remote equipment, residential homes or fed directly back into the power grid and used as environmentally clean energy. Energy content of sunlight: sunlight has an energy content of 1kW (1000 watts) per square meter. The typical Solar Panel achieves between 10% and 15% efficiency conversion. Solar Power Protection System from Cooper Bussmann Figure 1 V+ The voltage output of a Solar Panel/Array is defined by the number of individual cells in series. An individual panel (see Fig. 1) is made up of a series string of photovoltaic cells. Globally there is a push for utilizing higher voltages (trending to 1000Vdc and above). A number of PV panels in series is termed a string A number of strings in parallel is called an array The vast majority of large Solar Farms in North America are 600Vdc, but following the lead from Europe to increase voltages up to 1000Vdc to achieve more efficiency. 2009 Cooper Bussmann 3

Photovoltaic System Overcurrent Protection Variations of Solar Panel Output The most widely used Solar Panels for systems greater than 20kW are the 4, 5 and 6 Poly-crystalline silicon type. The Silicon type panel can achieve up to approx 7.5A maximum power current per panel. Again there is no specific preference as economics also play a role in the selection of Solar Cell type. A word of caution is do not assume all 4, 5 and 6 Solar panel designs are equal between different manufacturers. The maximum power output current of the panels can vary as much as 35% between manufacturers of equal solar cell dimension designs always select proper conductors/fuses based on the specific I sc * characteristics of the manufacturers specification. *I sc : Short circuit current Overcurrent Protection of PV Systems The National Electrical Code defines the maximum circuit current as 125% of the short-circuit current of the PV module (I sc ). The conductors and the overcurrent protective device are then sized at 125% of the maximum circuit current or 1.56 x I sc. Additionally, International standards such as BS EN7671 Sec 712 for Solar Photovoltaic (PV) Power Supply systems specify that conductors current carrying ability must be equal to or greater than 1.25 x I sc STC* at any location. The I sc is published by the PV module manufacturers on datasheets. The I sc is typically only 110-115% of the maximum power current (I pm ) of the PV module. This means that unlike typical grid connected AC systems, the available short circuit current is limited and the overcurrent protective devices will need to operate effectively on low levels of fault current. For this reason Cooper Bussmann has conducted extensive research and development of fuses that are specifically designed and tested to safely protect PV systems with high DC voltages and low fault currents. DCM - 600Vdc PV - 1000Vdc DCM - 600Vdc *I sc STC: The Electrical data applies under Standard Test Conditions (STC): Radiation 1000 W/m 2 with a spectrum of AM 1.5 and at cell temperature of 25 o C. PV Fuse - 1000Vdc 4 2009 Cooper Bussmann

Selecting Fuse Links for PV String Protection Depending on the desired capacity of the PV system, there may be several PV strings connected in parallel to achieve higher currents and subsequently more power. PV systems that have three or more strings connected in parallel need to have each string protected (systems that have less than three strings will not generate enough fault current to damage the conductors/equipment and therefore do not present a safety hazard as long as the conductor was sized properly based on local code requirements). Where three or more strings are connected in parallel a fuse on each string will protect the conductors from damage and help minimise any safety hazards. It will also isolate the faulted string so that the rest of the PV system can continue to generate electricity. Protection of Conductors Isolate damaged PV modules PV Fuse Selection Flow-Chart Define Solar Panel Spec I pm I sc Max System Voltage I pm : current at maximum power I sc : short-circuit current Define conductor/fuse size per string 1.56 x I sc = I conductor/fuse rating withstand @ 80 o C (Panel Back plane temperature influence, ambient temp influence) Define number of parallel solar panels/strings N = parallel panels/string PV String Fuse I n = 1.56 x I sc Select equal to or next higher std fuse rating PV String Fuse V n => Max System Voltage Yes Does array max I sc exceed continuous current rating of conductor selected? Max Array I sc = (N-1) *I sc No No Apply PV fuse to + and - Strings No PV String Fusing required 2009 Cooper Bussmann 5

Photovoltaic System Overcurrent Protection Fuse Rating for PV Applications Once it has been determined that maximum short-circuit current ([N-1]*I sc ) exceeds continuous current rating of conductor, follow the recommendations of selecting the proper PV string fuse. Example 1: Solar Panel String Fusing I sc = 5.37A I pm = 4.83A Max System Voltage = 1000Vdc (max value of series panels) Conductor Size Formula = 1.56 * I sc = 1.56 * 5.37 = 8.38A Conduct Size = 14AWG or 2.5mm 2 = 10.25A @ 80 o C Typical Solar Panel Specification Module Description Cell Type Polycrystalline Silicon Cell Size 125mm 2 (5") No of Cells and Connection 72 in Series Maximum System Voltage 1,000Vdc Electrical Data Maximum Power Voltage (Vpm) 34.6V Open Circuit Voltage (Voc) 43.1V Maximum Power Current (Ipm) 4.83A Short Circuit Current (Isc) 5.37A N = 4 (4 parallel Solar Panel Strings) Array Max I sc = (N-1) * I sc = (4-1) * 5.37 = 16.11A Array Max I sc is greater than conductor withstand, therefore string fuses are required I n = 1.56 x I sc (individual panel only) = 8.37A min fuse rating Select next higher std rating of 10A: PV-10A10F Fuse selected will protect selected conductor Min wire size: 14AWG or 2.5mm 2 = 10.25A @ 80 o C 6 2009 Cooper Bussmann

DCM Fuses Technical Data 1/10-30A/600Vdc Description Full range of DC Midget in 10x38mm AC Maximum Interrupting Rating of 100kA at 600Vac DC Maximum Interrupting Rating at 50kA at 600Vdc DC Minimum Interrupting Rating of 200% rated current at 600Vdc Catalogue Symbol DCM Type of Operation Fast-acting 1/10 to 30A Fuse holders Recommended fuse blocks/fuse holders for 10x38mm fuses: - Open fuse blocks: BM Series, 3743 - Finger-safe fuse holders: OPM-NG-SC3, OPM-NG-SM3, OPM- 1038, CHMD Series - Panel mount fuse holders: HPF Series, HPS Series, HPG & HPD, HPM Series, HPC-D, HPS2 Series Time-Current Curves Standards/Approvals UL Listed STD 248-14 (File E19180, Guide JDYX) CSA Certified C22.2 NO 248.14 (Class 1422-01, File 53787) Ratings Rated voltage: 600Vdc Amps: Breaking capacity: Packaging MOQ: 10 Packaging Dimensions - in 1/10 to 30A 100k at 600Vac 50k at 600Vdc 2009 Cooper Bussmann 7

Photovoltaic System Overcurrent Protection PV Fuse Link Technical Data 1-15A/1000Vdc Description A range of 10x38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string arrays (reverse current, multi-array fault). Catalogue Symbol/Fixing PV-(amp rating)a10f - Cylindrical PV-(amp rating)a10-t - Bolt PV-(amp rating)a10-1p - Printed Circuit Board PV-(amp rating)a10f-2p - Printed Circuit Board Class of Operation gr - (PV) Dimensions - mm Standards/Approvals Manufactured in accordance with IEC 60269 Ratings Volts: 1000Vdc Amps: 1 to 6A, 8A, 10A, 12A & 15A Breaking Capacity: 33kA dc Min Interrupting: 1.3 x I n PV Fuse Link Coordination with: 4, 5 & 6 solar cells Time constant (L/R): Under 1ms Packaging MOQ: 10 Packaging 100% recyclable Fuse Holders PCB clip: 1A3400-09 Modular fuse holder: CHM1D Time-Current Curves * Refers to fixing/mounting types, for example PV-15A10F 8 2009 Cooper Bussmann

Fuse Block For PV and DCM Fuse Links - BM Fuse Block Description Type M fuse block for use with any 10x38 fuses Dimensions - in Catalogue Symbol BM Series DIN Rail Adapters DRA-1 and DRA-2 2 and 3 poles also available Standards/Approvals UL Recognized, UL 512, Guide IZLT2, File E14853 CSA Certified C22.2 No 39, Class 6225-01, File 47235 BM603xPQ self certified for 1000Vdc Fuse Holders For PV and DCM Fuse Links - CHMD and CHM1D-PV-IEC Modular Fuse Holders Description The CHMD and CHM1D-PV-IEC modular fuse holders, accommodates 10x38mm fuse links Catalogue Symbol CHMD Series CHM1D-PV-IEC Dimensions - mm Ratings CHMD Series is rated at 690Vdc CHM1D-PV-IEC is rated at 1000Vdc Standards/Approvals CHMD Series UL Recognized UL512, Guide IZLT2, File E14853, CSA Certified C22.2 No 39, Class 6225-01 File 47235. Approvals at 600Vdc. CHM1D-PV-IEC, type test certificate of compliance with IEC 60269-1 for a rating of 1000Vdc. 4-pole unit shown by way of example Fuse Clips For PV and DCM - 1A3400 Series Description Fuse clip for 10mm diameter fuses with end stops and straight leads 20 Amps maximum Dimensions - in (mm) Catalogue Symbol: 1A3400 Footprint - in (mm) B A B A = 1.625 (41.28) B = 0.405 (10.29) C = (4 holes) = 0.091-0.095 (2.31-2.41) For board thickness up to 0.125 (3.18) C 2009 Cooper Bussmann 9

Cooper Bussmann Products and Technical Expertise Delivered Worldwide Customer Assistance Customer Satisfaction Team The Cooper Bussmann Customer Satisfaction Team is available to answer questions regarding Cooper Bussmann products. Calls can be made between: United States: Monday Friday, 8:00 a.m. 4:30 p.m. for all US time zones. The Customer Satisfaction Team can be reached via: Phone: 636-527-3877 Toll-free fax: 800-544-2570 E-mail: busscustsat@cooperindustries.com Emergency and After-Hours Orders To accommodate time-critical needs, Cooper Bussmann offers emergency and after-hours service for next flight out or will call. Customers pay only standard price for the circuit protection device, rush freight charges and a modest emergency fee for this service. Emergency and after-hours orders should be placed through the Customer Satisfaction Team. Call: Monday Friday, 8:00 a.m. 4:30 p.m. Central Time 636-527-3877 After hours 314-995-1342 Europe: Monday-Thursday 7.30 am - 5.30 pm GMT Friday 7.30 am - 5.00 pm GMT The Customer Satisfaction Team can be reached via: Phone: 00 44 (0) 1509 882 600 Fax: 00 44 (0) 1509 882 786 E-mail: bulesales@cooperindustries.com Application Engineering Application Engineering assistance is available to all customers. The Application Engineering team is staffed by university-qualified electrical engineers who are available by phone with technical and application support United States: Monday Friday, 8:00 a.m. 5:00 p.m. Central Time. Application Engineering can be reached via phone, fax or email: Phone: 636-527-1270 Fax: 636-527-1607 E-mail: fusetech@cooperindustries.com Europe: Monday Thursday 8.30 am 4.30 pm GMT Friday 8.30 am - 4.00 pm GMT Application Engineering can be reached via phone, fax or email: Phone: 00 44 (0) 1509 882 699 Fax: 00 44 (0) 1509 882 794 E-mail: buletechnical@cooperindustries.com Online Resources Visit www.cooperbussmann.com for the following resources: Product cross reference Product Data Sheets Product Profiles Online catalogues for the latest United States and European Catalogues 2009 Cooper Bussmann UK Ltd Melton Road, Burton-on-the-Wolds LE12 5TH, United Kingdom 00 44 (0) 1509 882 600 www.cooperbussmann.com Reorder # SOLARBROCH0909