Healthcare Solutions Room Pressure Monitors and Controls



Similar documents
COMBIMASS. Technical Data COMBIMASS eco-bio +

STERILIZERS, LABORATORY DRYING OVENS

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Hazardous Drug. Cleanroom. Standards

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Bring the fresh in. Dedicated Outside Air Systems

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

How To Control A Pressura Room Pressure Monitor

Fundamentals of Mass Flow Control

SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

PRODUCT PROFILE FEATURES

AMD-33 Air Measuring Station with VCD-33 Control Damper

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

CE6500 Energy Recovery Ventilator

Essam E. Khalil

HEALTH CARE GUIDELINES AND STANDARDS

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

CBD-233. Fire Alarm and Detection Systems

Variable Air Volume - VAV

Venturi Air Valve or Single-Blade Damper What s Right for You?

Element D Services Heating, Ventilating, and Air Conditioning

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

T5000 T000 LCD Digital Fan Coil Thermostat

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

CHAPTER 4 VENTILATION

Cooling Capacity CFM in. w.c. (125 Pa)

T7560A,B,C Digital Wall Module

Demand Based Static Pressure Reset Control for Laboratories

Tim Sisson - Trane HVAC OVERVIEW

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

MECHANICAL PRODUCTS VOLUME 1

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS


CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

API Marine. BMS Presentation. Ballast Measurement Systems

ENHANCED LABORATORY HVAC SYSTEM

Bill Mixon, RPh, MS Senior Associate Gates Healthcare Associates

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Lesson 36 Selection Of Air Conditioning Systems

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

F9MXE. Product Specifications

Fundamentals of HVAC Control Systems

Acoustical Design Guidelines for HVAC Systems in Schools

PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER W/LON/BACNET

HVAC Processes. Lecture 7

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Safety Requirements Specification Guideline

Intelligent Vibration Monitoring

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Designed for multi-injector endurance testing, the

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

How To Use A Ds340 (Dsp)

Cooling Capacity CFM in. w.c. (125 Pa)

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

ECOCIAT. Domestic hot water heat recovery unit

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

How To Control A Medical Device With A Pc System

HART HSSD High Sensitivity Smoke Detection

HVAC and Lighting Control Products for Open Building Automation Systems

FVA/A1 saturated-steam sterilizer

Element D Services Plumbing

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

All of the above software and firmware are included in the VAV-B Package. Contact Customer Service or Technical Support for this, or for cables.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

SMART SENSOR COLLECTION

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

LABORATORY DESIGN HANDBOOK

Environmental Monitoring

Ventilation Standard For Health Care Facilities

Digital inductive conductivity transmitter

INSIDE WDDCMON. User s Guide for the ENVIRO-TEC DDC Control System Windows Based Software

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SLIM LINE FUME HOOD MONITOR

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

MULTIZONE APPLICATION OF SOLUTION UNITS

APC APPLICATION NOTE #112

PNEUMATIC CONTROLS Selection and Description

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

Battery Powered Thermal Mass Flow Meters for Gases

Medical Air Systems: Scroll

Transcription:

Healthcare Solutions s and Controls

TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such as isolation rooms, operating rooms, and compounding pharmacies. The PMT meets both the ASHRAE 170 Healthcare Ventilation Standard and the USP 800 and USP 797 Hazardous Drugs - Handling in Healthcare Settings requirements. Using an innovative contamination resistant pressure sensor, the PMT can accurately measure room pressure without risk of degradation over time. The PMT utilizes native BACnet MS/ TP communication to seamlessly connect into your building management system. The PMT is BTL certified, providing simple yet dependable network integration. The PMT measures the differential room pressure through the low-profile room pressure sensor (RPS) assembly. The PMT s sleek, modern design and intuitive menu system ensures ease of set-up and use. APPLICATIONS SENSOR TECHNOLOGY Comparison of Price sensor to diaphragm sensor technology. Comparison of published accuracies. Room Pressure Reading 0.020 0.018 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 0.000 0 1 2 3 4 Time (Years) Comparison of Price sensor to thermal anemometer sensor technology. Effects of a lint and dust saturated environment. Pressure Reading 0.016 0.014 0.012 0.010 0.008 0.006 Price Sensor Error Range Reference Pressure Diaphragm Sensor Error Range Price Sensor Reference Diaphragm Sensor Thermal Anemometer Sensor PRODUCT FEATURES PMT Features Maintenance free pressure sensor Native BACnet MS/TP High resolution 480x800 touchscreen display Multi-stage surge protection against voltage spikes on 24 VAC input Audible and visual alarms LED side bars that offer 180 degree viewing of current room status Multi-level password protected menus Setup Wizard walk through setup of PMT when first powered up Fire retardant, antimicrobial ABS case PMT Options Door Switches can be combined with the PMT, creating allowances for the alarms to be disabled when doors are opened meeting the ASHRAE 170 requirement for preventing nuisance alarms Room Mode Key Switch enables rooms to be easily changed from isolation to setback mode in VAV systems Analog pressure output Alarm relay contact TOUCHSCREEN ROOM PRESSURE MONITOR (PMT) Airborne Infectious Isolation (AII) and Protective Environment (PE) rooms -- Meets ASHRAE 170 Healthcare Ventilation Standard monitoring requirements Operating rooms -- Meets ASHRAE 170 Healthcare Ventilation Standard monitoring requirements 0.004 0.002 0.000 0 50 100 150 200 250 Time (Days) RPS Features Maintenance free Simple connections using plug and play RJ-12 jack Stainless steel louvered wall plate Indicator LED shows proper connection Pharmacy: Harmful drug and compounding buffer rooms -- Meets USP 800 and USP 797 Hazardous Drugs - Handling in Healthcare Settings requirements ROOM MODE KEY SWITCH ROOM PRESSURE SENSOR (RPS) 1-Healthcare Solutions Healthcare Solutions-2

ISOLATION ROOM SOLUTIONS A dynamic offset room pressure control strategy is created by utilizing volumetric tracking control, with the added feature of adjusting the airflow offset based on actual room pressure as measured with the through-wall sensor. This ensures the desired pressure differential is maintained throughout the life of the room. Thermostat LCD or blank face options Full setup and balancing functions Humidity sensing option Room Pressure Controller Native BACnet MS/TP (BTL Listed) Controls differential pressure between spaces (up to 2) Control of up to 4 valves or terminals Temperature and humidity control Exhaust Venturi Valves Electronic airflow feedback prevents dust/lint contamination from degrading airflow reading Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation Characterized and calibrated using Analog operating pressure feedback GENERAL REQUIREMENTS ASHRAE 170 Section 7.1-7.2 Minimum differential pressure of 0.01 in.w.c. (2.5 Pa). Permanently installed device(s) to continuously monitor the differential pressure. Visual indication when differential pressure is not maintained. Switch of pressure relationships between spaces from positive to negative, and vice versa, shall not be permitted. Minimum of 12 air changes per hour. Air changes can be reduced when the space is unoccupied, provided that the required pressure relationship is maintained. ROOM TYPES Airborne Infectious Isolation (AII) rooms shall be at a negative pressure with respect to the corridor or common space. Protective Environment (PE) rooms shall be at a positive pressure with respect to the corridor or common space. Combination Airborne Infectious Isolation/Protective Environment (AII/PE) rooms shall maintain one of the following pressure relationships: 1. The anteroom shall be at a positive pressure with respect to both the AII/PE room and the corridor or common space. 2. The anteroom shall be at a negative pressure with respect to both the AII/PE room and the corridor or common space. 3-Healthcare Solutions Supply Terminal Unit Capacities ranging from 50 8,000 cfm in 11 sizes Performance certified in accordance with the AHRI 880 certification program SP300 multipoint flow sensor designed to maintain control accuracy independent of field installation conditions Room Pressure Sensor Maintenance and calibrationfree sensor technology Accurate to 3% of reading + 0.0008 in.w.c. (0.02 Pa) Designed to prevent buildup of airborne particulates Touchscreen Elegantly designed with the industry s highest resolution Innovative side-bar room status indicator BTL certified for reliable BACnet integration Available pressure alarm delays to help prevent nuisance alarms Healthcare Solutions-4

OPERATING ROOM SOLUTIONS Volumetric offset room pressure control is one of the most common and dependable approaches to controlling room pressure in operating rooms. Tracking pair VAV control is designed to maintain an offset between supply and exhaust valves to facilitate directional airflow control between adjacent spaces. Tracking Controller Native BACnet MS/TP (BTL Listed) Maintains offset during occupied and unoccupied periods Discharge air temperature control for spaces with high air change rates Exhaust Venturi Valves Electronic airflow feedback prevents dust/lint contamination from degrading airflow reading Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation Characterized and calibrated using Analog operating pressure feedback GENERAL REQUIREMENTS ASHRAE 170 Section 7.4 Room to maintain positive pressure with respect to all adjoining spaces at all times. Thermostat Minimum differential pressure of 0.01 in.w.c. (2.5 Pa). LCD or blank-face options Full setup and balancing functions Humidity sensing option Minimum of 20 air changes per hour. Air changes can be reduced when the space is unoccupied, provided that the required pressure relationship is maintained. If pressure-monitoring device alarms are installed, allowances shall be made to prevent nuisance alarms while doors are moving or temporarily open. Supply Terminal Unit Capacities ranging from 50 8,000 cfm in 11 sizes Performance certified in accordance with the AHRI 880 certification program SP300 multipoint flow sensor designed to maintain control accuracy independent of field installation conditions Room Pressure Sensor Maintenance and calibrationfree sensor technology Accurate to 3% of reading + 0.0008 in.w.c. (0.02 Pa) Designed to prevent buildup of airborne particulates 5-Healthcare Solutions Touchscreen Elegantly designed with the industry s highest resolution Innovative side-bar room status indicator BTL certified for reliable BACnet integration Available pressure alarm delays to help prevent nuisance alarms Healthcare Solutions-6

COMPOUNDING PHARMACY SOLUTIONS Maintenance and calibrationfree sensor technology Accurate to 3% of reading + 0.0008 in.w.c. (0.02 Pa) Designed to prevent buildup of airborne particulate Hazardous Drugs (HD) must be handled under conditions that promote worker safety and environmental protection. Volumetric offset is typically used to maintain room pressurization. Compounding pharmacies are constant volume spaces, operating at high air change rates 24/7. Exhaust airflow requirements can often be met with BSC exhaust in buffer isolation rooms, requiring a constant volume supply valve to provide offset control. Room Pressure Sensor Room Pressure Controller Exhaust Venturi Valves Electronic airflow feedback prevents dust/lint contamination from degrading airflow reading Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation Characterized and calibrated using Integrated silencer options Analog operating pressure feedback Native BACnet MS/TP (BTL Listed) Controls differential pressure between spaces (up to 2) Control of up to 4 valves or terminals Temperature and humidity controls GENERAL REQUIREMENTS USP 797/800 A continuously operated biological safety cabinet (BSC) or compounding aseptic containment isolator (CACI) is used in the preparation of hazardous drugs (HDs). The drug preparation area is an isolated space kept at a negative pressure with respect to adjacent spaces. Required pressure differential: 0.01-0.03 in.w.c. Supply Venturi Valves Thermostat Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation Characterized and calibrated using Analog operating pressure feedback LCD or blank-face options Full setup and balancing functions Humidity sensing option Required air change rate for nonsterile HD compounding: 12 ACPH. Required air change rate for sterile HD compounding: 30 ACPH. Room differential pressures to be continuously monitored and indicated. USP recommends separate rooms for sterile and nonsterile compounding. Constant Volume Venturi Valve Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation Characterized and calibrated using Analog operating pressure feedback Optional corrosion resistant coatings 7-Healthcare Solutions Touchscreen Elegantly designed with the industry s highest resolution Innovative side-bar room status indicator BTL certified for reliable BACnet integration Available pressure alarm delays to help prevent nuisance alarms Healthcare Solutions-8

APPLYING TERMINAL UNITS AND VENTURI VALVES Price Venturi Valves (VV) are mechanically pressure independent airflow control devices designed specifically for critical applications. The high concentrations of lint found in exhaust air streams (from frequent gowning/linen changes) in the healthcare environment typically require a rigorous cleaning/maintenance cycle to airflow-measuring terminal units. This makes the Price Venturi Valve s insensitivity to effects of dust/lint on airflow measurement an essential advantage in healthcare applications. Single duct terminal units (SDV) can often be successfully applied as the supply airflow devices in healthcare environments. These spaces typically do not require high turndown ratios or high speeds of response, and the filtered supply air stream is typically devoid of the levels of dust and lint required to degrade the reading of airflow sensors. Use the table below to determine which valve type best meets your requirements. PRODUCT FEATURE LIST FEATURE VV Venturi Valve (VV) SDV Single-Duct Terminal Unit (SDV) Minimum Operating Pressure Turndown Ratio Sound Level Airborne Particulate Insensitivity Inlet/Outlet Insensitivity Variable rate stainless steel conical spring Integral BTL listed native BACnet controls A hybrid solution using supply terminal units and exhaust venturi valves can offer the best performance in airflow accuracy, and sound power levels, as well as low initial purchase and operating costs. DETAILS Terminal units typically have a lower minimum operating pressure than venturi valves, contributing to energy and cost savings. Venturi valves have higher turndown ratios than conventional terminal units, facilitating energy savings during unoccupied hours. Terminal units typically have lower sound levels compared with venturi valves. Integral silencers are available for all airflow devices to improve acoustical performance. The accuracy of airflow sensors typically found in terminal units can be negatively impacted by the buildup of airborne lint. Venturi valves control flow based on factory calibration and characterization without the use of flow sensors, leaving them unaffected by particulates in the airstream. Terminal unit flow sensors typically require three duct diameters of straight duct leading into and out of the valve. Venturi valve performance is virtually unaffected by inlet or outlet duct configurations. Valve pressure measurement with analog pressure signal output Standard speed fail in place actuator for healthcare applications. Additional actuator options available. Price Venturi Valves offer advantages in: High turndown ratio High speed of response No inlet/discharge straight-duct requirements Low maintenance due to the absence of direct airflow measuring devices in the airstream MONITOR & CONTROL SELECTION Use the table below to determine which healthcare control or monitor solution best meets your requirements. PRODUCT SELECTION GUIDE FEATURE PM PMX Room Pressure Monitor Deluxe PMT Touchscreen Room Pressure Monitor PC Room Pressure Controller TC Tracking Controller VC Valve Controller Direct Pressure Control Dynamic Pressure Control Volumetric Offset Control Temperature Control Humidity Control Pressure Monitor Secondary Room Support BACnet Communication Analog Pressure Output Remote Station Interface Door Switch Input Key Switch Interface Touchscreen Display 9-Healthcare Solutions Healthcare Solutions-10

Please visit pricecriticalcontrols.com or contact a representative for additional product information.