RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY



Similar documents
Thin Layer Chromatography.

Separation of Amino Acids by Paper Chromatography

Paper Chromatography: Separation and Identification of Five Metal Cations

For Chromatography, you must remember Polar Dissolves More, not like dissolves like.

PAPER CHROMATOGRAPHY

Thin Layer and Column Chromatography

Organic Lab 1 Make-up Experiment. Extraction of Caffeine from Beverages. Introduction

Planar Chromatography

Experiment 5: Column Chromatography

Lab 6: Paper Chromatography. Pages Pre-lab page 151 No Post lab Chromatogram must be turned in attached to lab report

EXPERIMENT 1 - Determination of the purity and identity of organic compounds by melting point and/or analytical thin layer chromatography

THIN LAYER CHROMATOGRAPHY AND MELTING POINT DETERMINATION: DETECTION OF CAFFEINE IN VARIOUS SAMPLES

Ink Analysis 2005, 2004, 2002, 1993 by David A. Katz. All rights reserved.

PHYSICAL SEPARATION TECHNIQUES. Introduction

ISOLATION OF CAFFEINE FROM TEA

EXPERIMENT Aspirin: Synthesis and NMR Analysis

Forensic science ( 科 學 鑑 證 ):

Separation of Dyes by Paper Chromatography

PURIFICATION TECHNIQUES

Fractional Distillation and Gas Chromatography

Hands-On Labs SM-1 Lab Manual

ASPARTAME The Study of a Peptide Bond

Polarity and Properties Lab PURPOSE: To investigate polar and non-polar molecules and the affect of polarity on molecular properties.

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

Separation by Solvent Extraction

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

Lab: Properties of Polar and Nonpolar Substances

Purification of reaction mixtures using flash chromatography.

Recrystallization II 23

Experiment 3: Extraction: Separation of an Acidic, a Basic and a Neutral Substance

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

8.9 - Flash Column Chromatography Guide

Stains for Developing TLC Plates

Target Mole Lab. Mole Relationships and the Balanced Equation. For each student group Hydrochloric acid solution, HCl, 3 M, 30 ml

Thin Lenses Drawing Ray Diagrams

Chromatography...Oh Yeah!

SUCRALOSE. White to off-white, practically odourless crystalline powder

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

The Water Race: Hydrophobic & Hydrophilic Surfaces

Examples of Math Applications in Forensic Investigations Anthony and Patricia Nolan Bertino Bertino Forensics

Multiple Choice For questions 1-10, circle only one answer.

Experiment 5 Preparation of Cyclohexene

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

EXPERIMENT 1 (Organic Chemistry I)

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Chemical Bonding: Polarity of Slime and Silly Putty

PREPARATION AND PROPERTIES OF A SOAP

oxidize 4-Cholesten-3-one

Chapter 5 Classification of Organic Compounds by Solubility

Measuring volume of gas produced Measuring precipitation (because sulphur is produced) e.g. look for X to disappear Measure mass lost

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Food Dye Chromatography Student Laboratory Kit

EXPERIMENT Oil of Wintergreen: Synthesis and NMR Analysis

Melting Point, Boiling Point, and Index of Refraction

1. The Determination of Boiling Point

Mixtures and Pure Substances

w w w. c a ro n fo re n s i c s. c o m Processes to Develop Latent Prints on Porous Surfaces August By: Bob dotterer, applications engineer

# 12 Condensation Polymerization: Preparation of Two Types of Polyesters

Recovery of Elemental Copper from Copper (II) Nitrate

CHM220 Addition lab. Experiment: Reactions of alkanes, alkenes, and cycloalkenes*

Chapter 14 Solutions

Chemical versus Physical Changes

MAKING A BETTER MARK WITH INK JET As substrates, industry regulations and customer demands change, fluids are also evolving

Experiment 14 Preparation of p-nitroaniline

Conservation of Momentum Greg Kifer

Tin Man Electrolysis

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Isolation of Caffeine from Tea

WORKSHEET: ph and Water 23 Lab Instructor: Lab Day & Time: Student name(s): drain cleaner flat soda pop window cleaner ammonia.

Experiment 2 Extraction of Chlorophyll and Carotenes from Spinach and Analysis by Thin Layer Chromatography

Determination of a Chemical Formula

Acid-Base Extraction.

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Background Information

Written By Kelly Lundstrom & Kennda Lynch January 31, 2012 Milk Dye ACTIVITY PLAN

Unit title: Chemical Laboratory Techniques

Experiment Notebook Format. Experiment Notebooks will be distributed during the first weeks of the second Quarter.

Extraction of Caffeine from Energy Drinks

Experiment #8 properties of Alcohols and Phenols

Organic Chemistry Lab Experiment 4 Preparation and Properties of Soap

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

H H H O. Pre-Lab Exercises Lab 6: Organic Chemistry. Lab 6: Organic Chemistry Chemistry Define the following: a.

IDENTIFICATION OF POLYMERS 1998 by David A. Katz. All rights reserved

Experiment 12- Classification of Matter Experiment

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

Extraction: Separation of Acidic Substances

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

LATENT FINGERPRINT ENHANCEMENT II: FUMIGATION TECHNIQUES

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

Fiber Analysis 2005, 2004, 2003, 2001, 1999 by David A. Katz. All rights reserved.

Lab Exercise 3: Media, incubation, and aseptic technique

7. Thin-Layer Chromatography

Taking Apart the Pieces

Diffusion and Fluid Flow

Transcription:

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY Have your lab textbook available for quick reference to specific pages, indicated in red. BASIC PRINCIPLES OF CHROMATOGRAPHY Chromatography is yet another technique for the analysis and separation of chemical mixtures. The technique is based on a polarity interplay between the sample and two other substances called the solid (or stationary) phase, and the mobile phase, which can be a liquid or a gas. As their names indicate, the stationary phase does not move, whereas the mobile phase flows across, or through the solid phase. In this love triangle, the sample to be separated first becomes adsorbed onto the surface of the solid phase through polar interactions. More polar samples adhere (or bind) more strongly than less polar ones. The mobile phase then comes in and sweeps across the stationary phase, competing for the sample. If the mobile phase is a solvent, it is called the eluting solvent. The more polar the solvent, the greater its capacity to carry the components of the mixture with it, yanking them away from the solid phase as it moves. Different components with different polarities will travel at different rates as the solvent moves, causing their separation. 1. 1. Initial state. state: Sample is adhered adsorbed onto on the solid the solid phasephase. sample mixture stationary phase, or solid support 2.Eluting 2. Eluting solvent solvent begins to flow flow through through the solid the phase. solid phase. eluting solvent 3. 3. As As the the solvent solvent moves, moves, the the c components of the mixture move moveat at different rates. the less polar component travels faster. the more polar component the travels more slower. polar component travels slower. Some of the most common solid adsorbents used as stationary phases in chromatography are listed in table 19.1, p. 760. In the organic chemistry lab the most commonly used are silica gel and alumina due to their versatile polarity range. Likewise, some common eluting solvents are listed in table 19.2, p. 761 by order of increasing polarity, and therefore increasing eluting power. Methylene chloride, ethyl acetate, and ethanol are among the most commonly used. Table 19.3, p. 762, lists some functional groups by order of elution, meaning how fast they move in a chromatographic separation. Again, the more polar ones (alcohols, amines, and acids) move slower, whereas the less polar ones (hydrocarbons and ethers) move faster. THIN LAYER CHROMATOGRAPHY (TLC) In thin layer chromatography the solid phase (silica gel or alumina) is applied as a thin coating on a plastic sheet or glass slide, called a TLC plate (fig. 20.4, p. 783). Using a capillary tube, a solution of the sample is applied on the solid support as a spot, a technique known as spotting. When the sample dries it becomes adsorbed onto the solid support. This process can be repeated several times to produce a more concentrated spot.

SPOTTING TECHNIQUE 1. Throughout these operations, keep in mind that the coating on the TLC plate is very fragile and easily chips. Plates must be handled with care. 2. Using a pencil, not ink, draw a horizontal line about 1 cm from the bottom of the TLC plate to mark the starting point of the sample for elution. Do not apply too much pressure, or you will break the coating. The sample spots are to be applied on this horizontal line. 3. Dip the tip of a capillary micropipette in a solution of the sample to be analyzed. Capillary action will cause the liquid to rise up the pipette. 4. Lightly touch the solid support with the tip of the micropipette as if using a fountain pen. A small amount of solution will transfer to the plate forming a spot. As with a real pen, the longer you leave the pipette in contact with the plate the bigger the spot. We don t want big spots, therefore just peck the coating and withdraw the pipette. 5. Wait until the spot dries before applying the next one, which should be done on exactly the same place. With most solutions, 3 or 4 applications of the same solution should suffice to produce a good spot. A spot that s too dense or too big can cause problems during the separation. 6. If you are applying several different samples on the same plate, make sure their spots do not touch each other. Adjacent spots must be separated by a minimum distance of 0.5 cm, or they ll run into each other during the separation. 7. Likewise, spots must not be too close to the edge of the plate, or they can run off the plate during separation. Again, spots should be separated from the edges by a minimum of 0.5 cm, except for the bottom of the plate, in which case they should be separated by a minimum of 1 cm. The reason is that the plate will be immersed in the eluting solvent to effect the separation, and the eluting solvent should not touch the spots when the separation begins. THE DEVELOPING CHAMBER While the spots are being applied and allowed to dry, prepare a developing chamber for the separation (that s a fancy name for a beaker or jar that s slightly taller than the TLC plate). Refer to fig. 20.5 on p. 784. To do this take a clear container and place a small amount of eluting solvent inside, just about enough to cover the bottom. You can also take a piece of filter paper whose diameter is about the height of the container and place it around the walls. Squirt some of the eluting solvent on the filter paper to make it wet so that it adheres to the walls better. This keeps the space inside the container saturated with solvent vapors to minimize loses by evaporation and improve the separation. Also have a lid or watch glass ready to cover the container during the separation. ELUTION TECHNIQUE Once the TLC plate has been spotted and ready to go, carefully place it inside the developing chamber, trying to avoid splashing. Remember, we don t want the solvent to touch the spots before we start the separation. If it does, it will cause the spots to smear and they ll become useless. The plate should be placed upright, slightly inclined against the wall of the container. The solvent should not touch the spots when the separation first begins, that s why its level should be below the spots by at least 0.5 cm. Cover the container and wait for elution to proceed. By capillary action, the solvent will immediately start rising up the TLC plate. As soon as it comes into contact with the spots, it will cause the less polar components of the mixture to start moving. The more polar components will also move, but at a less noticeable rate. The following diagram illustrates the process.

PART A Separating the components of a mixture using a given solvent. solvent front solvent front 1 cm I Initial TLC TLC plate plate with with spot spot pencil line initial spot TLC plate inside the developing chamber solvent level As the solvent moves up, it will cause the spot to move as well A good solvent causes causes good good s separation of the of the mixture components components of the mixture. When the plate is first placed inside the developing chamber, its bottom should be as parallel as possible with the solvent level. If the plate enters the solvent at an angle, it will cause a slanted solvent front line which may result in poor separation and uneven alignment of the spots. When the solvent front is about 0.5 to 1 cm from reaching the top, it s time to stop the elution. Do not allow the solvent front to reach the top of the plate. That may cause erroneous R f values and may cause spots that are close together to run into each other. Take the plate out with tweezers and mark the solvent front line with a pencil as soon as possible. If you wait too long, it will fade and you will miss a crucial part of information needed to calculate the R f values. If a poor separation is obtained with a certain solvent, the experiment needs to be repeated with a solvent of different polarity. As with crystallization, solvent mixtures can be used to achieve intermediate degrees of polarity. Low polarity solvents will cause the spots to move more slowly. High polarity solvents will do the opposite. Either extreme can cause poor separation. Only practice will enable you to gain a sense of how to reach a happy medium. PART B Finding the solvent that provides the best separation. A low polarity solvent may move the spots too slowly for a good separation A solvent of intermediate polarity produces the best results A solvent that s too polar may move the spots too fast for a good separation

VISUALIZATION TECHNIQUES After taking the TLC plate out of the developing chamber and marking the solvent front line, allow the plate to dry. Drying can be accelerated by placing the TLC plate on a lukewarm surface. Remember, the plate is made of plastic, if the plate is too hot the plastic will melt. Once the plate is dry, you need to be able to see the spots. Unless your sample is colored, this is not always possible with the naked eye. Visualization techniques are methods that enable you to see otherwise invisible spots. There are several methods available, but the two most commonly used in the organic lab are iodine staining, and use of a UV lamp. Iodine reacts with many organic substances to produce compounds which are brownish. Place the TLC plate inside an iodine chamber (again, a fancy name for a jar that contains a few iodine crystals). Close the jar, and within a few minutes spots will appear on the plate. This process can be accelerated by placing the chamber on a warm surface. Once you can see the spots, take the TLC plate out of the chamber with tweezers or wearing gloves (iodine is a toxic substance, and so are its vapors). Mark the spots with a pencil. Most commercial TLC plates contain not only the solid phase coating, but also a fluorescent substance that is sensitive to ultraviolet (UV) light. By shining UV light with a special lamp on the plate, the coating will appear greenish. If there are spots or other substances blocking the light, they will appear blackish. This will enable you to mark the places where the spots are with a pencil. Since iodine vapors are toxic, only the UV lamp will be used in the lab. CALCULATING R f VALUES The scientific measure of the chromatographic separation in TLC is the R f value, variously interpreted in different sources as retardation factor, ratio to the front, etc. (see p. 788). It is given by the expression R f = distance traveled by the spot distance traveled by the solvent front See fig. 20.8 on p. 788 for an example. Some spots are somewhat large, while others tail. Tailing tends to occur with ionic or highly polar substances that are reluctant to move because they bind too strongly to the solid phase. When this happens the center of mass of the spot is used to measure the distance traveled by the spot. The reaction with iodine as a visualization method is particularly good at revealing the densest part of the spot. center of mass distance traveled by the spot ] tailing By definition, R f values are always less than 1. An R f value of 1 or too close to it means that the spot and the solvent front travel close together and is therefore unreliable. This happens when the eluting solvent is too polar for the sample. Another run must be made using a less polar solvent to improve the separation. Likewise, if the spot hardly moves and its traveled distance is nearly zero, there has probably been no chance for separation. This happens when the eluting solvent is not polar enough for the sample. Another run must be made using a more polar solvent to improve the separation.

RELATIONSHIP BETWEEN R f VALUE AND POLARITY OF THE SAMPLE It was mentioned before that the polarity of the sample and its rate of movement are inversely related. The more polar spot travels slower, and the less polar spot travels faster. R f values, on the other hand, are directly related to the rate of movement. The fastest moving spot has the highest R f value. Therefore R f values and polarity are inversely related. The spot with the highest R f value is the least polar (fastest moving), and the spot with the lowest R f value is the most polar (slowest moving). USES OF R f VALUES IN TLC R f values are frequently used to compare a known and an unknown substance to determine if they are the same. As long as their spots are run simultaneously on the same plate, the argument can be made that if their R f values are the same, and if the general appearance of the spots is the same, then they are the same compound. R f values depend on: The polar nature of the solvent used Polar nature of the stationary phase Polar nature of the sample Conditions of the experiment R f values are therefore not exactly reproducible from one experiment to another, even if an effort is made to carry them under the exact same conditions. When comparing two or more substances, they must be run simultaneously on the same plate or the comparison is invalid.

EXPERIMENT 5: INSTRUCTIONS FOR PART B. Although the lab textbook proposes several compounds and solvents that you can use in part B, we will use only two substances and three solvents. The two substances are benzoin and benzil. The solvents are hexane (nonpolar), methylene chloride (moderate polarity), and acetone (polar). Therefore, you will spot three solutions onto each of three TLC plates: a. Benzoin only solution b. Benzil only solution c. Benzoin and benzil solution 1. PREPARE THREE TLC PLATES. Spot each plate with the above solutions, as follows: benzoin benzil benzoin + benzil 2. DEVELOP THE 3 PLATES AS FOLLOWS: Plate 1 in hexanes Plate 2 in methylene chloride Plate 3 in acetone. 3. CALCULATE R f VALUES for the spots in the three plates. 4. REPORT RESULTS explaining which solvent effected the best separation of the benzoin-benzil mixture (third spot), and why, based on polarity of the substances and the solvents used. The chemical structures of benzoin and benzil are given on p. 309 of the lab textbook, under Exp. 36B.