Precision Mass Flow Metering For CVD Applications.



Similar documents
A precision thermal mass flow sensor for (very) small liquid flows.

In semiconductor applications, the required mass flows

Fundamentals of Mass Flow Control

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Typical Aluminum GFM Mass Flow Meter

Precision Mass Flow Meters / Controllers for Liquids and Gases

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

COMBIMASS. Technical Data COMBIMASS eco-bio +

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Instruction manual. Mass Flow / Pressure meters and controllers for gases and liquids. Doc. no.: O Date:

Airflow Sensors Line Guide

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Model 111 Mass Flow Instruments

Thermal Flow Sensor Die

OEM-EP Pressure Controllers

T U R B I N E G A S M E T E R

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Sensor Integration on a W-CVD Cluster Tool for Real-Time Process Monitoring and Control

The Fundamentals of Gas Flow Calibration

Instruction manual. General instructions digital Mass Flow / Pressure instruments laboratory style / IN-FLOW. Doc. no.: U Date:

Gas Custody Transfer Calibration

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Micro Motion 3098 Gas Specific Gravity Meter

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Trace Gas Exchange Measurements with Standard Infrared Analyzers

BB-18 Black Body High Vacuum System Technical Description

OPTIMASS 6000 Technical Datasheet

Instruction manual. Mass Flow / Pressure instruments laboratory style / IN-FLOW ATTENTION. Doc. no.: N Date:

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Sanitary Type Electronic Flow Switches

Experiment # 3: Pipe Flow

VSO MAX HP High Flow Proportional Valve

Testing methods applicable to refrigeration components and systems

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

User s Manual Laminar Flow Elements

Battery Powered Thermal Mass Flow Meters for Gases

How To Use A Ds340 (Dsp)

Online Infrared Flue Gas Analyzer Gasboard 3000

THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INSTRUMENTS

Energy and Flow Measurement for Hydronic Systems

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

THE STRAIN GAGE PRESSURE TRANSDUCER

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

API Marine. BMS Presentation. Ballast Measurement Systems

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

How to measure absolute pressure using piezoresistive sensing elements

Stack Sampling Stack sampling or source sampling

FLUID FLOW Introduction General Description

Thermal Mass Flow Meters and Controllers for Gases

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Flow System Calibration in Medical and Bio-medical Production Processes.

RITTER Multiple Sonic Nozzle Calibration System

Thermostatic valve Type AVTA

Flow Measurement Options for Pipeline and Open Channel Flow

OPTIMASS 1400 Technical Datasheet

Battery Powered Thermal Mass Flow Meters for Gases

MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver Copyright(C) 2011 Tsukasa Sokken Co., Ltd.

E - THEORY/OPERATION

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Solenoid valves 2/2-way direct-operated Type EV210A

Digital inductive conductivity transmitter

Fiscal Measurement Natural Gas

COUNTERBALANCE VALVES

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Thermal Flow Sensors. Anemometers. Calorimeters. Ensemble of both

Material test chamber with mechanical convection

Overview. Inficon s Product

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

T0118 T2118 T3118. Instruction Manual

The Do s and Don ts of Pressure Transducers

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

For Multi-Parameter Meters see mvx

Designed for multi-injector endurance testing, the

Subminiature Load Cell Model 8417

Marine after-treatment from STT Emtec AB

Tube Liquid Sensor OPB350 / OCB350 Series

Laminar Flow Elements

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

In-Line Electronic Flow Switches

Incubator with mechanical convection

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermal Dispersion Mass Flow

Electronic Flow Switches

Overview of the state of the art heat measurement technologies for larger solar thermal systems

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology

Transcription:

Precision Mass Flow Metering For CVD Applications. Ir. H.J. Boer Research Department of Bronkhorst High-Tech B.V. Nijverheidsstraat 1A, 7261 AK Ruurlo The Netherlands. Tel: +31 (0)573 458800 Fax: +31 (0)573 458808 E-Mail: hjboer@bronkhorst.com Abstract Mass flow instruments play an important role in every CVD application. This paper will describe the basic characteristics of thermal mass flow metering and controlling of gases and liquids. The essential theoretical background will be given as well as information provided by the leading manufacturer in Europe. Also some practical uses of the instruments in CVD applications will be highlighted. With high accuracy and very good reproducibility the instruments are very well suited for the key role of controlling the fluids (gases and liquids) in CVD applications. 1. INTRODUCTION In almost every application involving Chemical Vapor Deposition, mass flow metering and control plays an important role in the experimental or production setup (see figure 1). Gas flow is needed as a carrier gas, as the reaction gas, and also for purging or throttling in a vacuum pump. Liquid flow instruments are used for DLI, Direct Liquid Injection, a rather new technique for controlling liquid precursors or water vapor. Almost every flow instrument used in CVD is based on the thermal measuring principle. In figure 2, a schematic cutaway of a typical mass flow controller (MFC) for gases can be seen. The components shown here; the capillary type sensor, the bypass (laminar flow element), the control valve and the electronic circuitry will be discussed in detail in this article. Special attention will be given to liquid flow control and DLI in CVD applications. Reaction gas Purging Carrier gas Vapor P.C.board Connector DLI Flow sensor Valve Throthling Dilluting Scrubbing Flow Laminar flow element Figure 1. A schematic setup for a CVD-System and the functions of Mass flow controllers therein. Figure 2. A schematic cross-view of a typical thermal mass flow controller.

2. THE CAPILLARY TYPE THERMAL MASS FLOW SENSOR The measuring principle of the thermal mass flow sensor is depicted in figure 3. The flow Φ is forced through a capillary tube, with thermal components mounted on the outside of the tube. When no fluid is flowing through the tube, the temperature profile is symmetric. When the flow>0, the temperature profile is shifted to the right. This shift is detected by the two temperature sensitive components (wire-wound resistors) T up and T down. For relatively small flows, the temperature difference T down - T up is proportional to mass flow. See the characteristic of the flow sensor in figure 4. Only the bottom (linear) portion of the sensor characteristic is used. The sensor is very stable. This leads to a very accurate and reproducible signal. The signal ( T) in the linear part of the characteristic can be given by: Signal = k ρ n c p Φ vn = k c p Φ m [1] Where: k is a configuration constant. ρ n = normal density c p is heat capacity at constant pressure Φ vn is normal volume flow Φ m is mass flow Φ m x Tup Heater Tdown sensor tube Φm =0 temperature of the sensor tube T=T down- T up Φ m >0 Signal working point 10 mln/min. Flow ambient emperature position x at the sensor tube Figure 3. A capillary Position tube based x at thermal sensortube mass flow sensor. Figure 4. A typical flow characteristic of a thermal flow meter. The subscript n is for normal conditions, 0 C and 1 atmosphere. In part two of formula 1, it can be seen that the thermal mass flow meter will be sensitive to mass flow. So the instrument is insensitive to changes in the pressure or temperature of the fluid. The use of volumetric flow units therefore is misleading and a bit confusing, but it is very common in day to day use (see also Flow Units). Typical dimensions of this type of flow sensor are inner diameter = 0.2 mm, outer diameter = 0.3 mm, length = 50 mm. The working point of a typical capillary type flow sensor is around 10 ml n /min (Air). Typical pressure drop (for Air at atmospheric conditions) across the sensor is 30 to 50 mbar. (See also Laminar Flow Elements). The signal ( T = T down - T up ) of the sensor is

measured by temperature sensitive resistors. The resulting R is converted to voltage by a Wheatstone bridge. (See also ch. 5: Electronic Circuitry). It is not uncommon for sensors to have only two thermal components. In that case the power is dissipated in the temperature sensitive resistors T down and T up. Flow units In thermal mass flow instruments, the most commonly used unit of (mass) flow is normalized volumetric flow. As an example, 1 l n /min (normal liter per minute) Argon means, the amount of Argon that will be present in a liter of Argon at normal conditions after a period of 1 minute. So 1 l n /min of Argon means 1.78 g/min of Argon (for the normal density of Argon ρ n = 1.78 g/liter). In this way, a normal volume flow is correlated to a mass flow. With this in mind, one can easily understand that these units are independent of temperature and pressure. The subscript s is also used. This stands for standard conditions of 20 C and 1 atmosphere. See table 1, for some most frequently used units of gas mass flow. NB: The above mentioned definitions are used in Europe. In the US, standard conditions usually mean 0 C and 1 atmosphere. Table 1. Most frequently used units of mass flow for gases. Unit Description l n /min Normal liters per minute l s /min Standard liter per minute m 3 s/h Standard cubic meters per hour sccm (USA) Standard cubic centimeter per minute SLPM (USA) Standard liter per minute Conversion Factors The conversion factor is an important consideration in thermal mass flow measurement. When an instrument is used for different fluids (gases) than originally calibrated for, the conversion factor is used to calculate the correct flow. For example, a flow controller is calibrated for 10 l n /min N 2. The instrument will be used for different gases. Table 2 shows the conversion factors to be applied for the gases. The flow rate of this instrument with Helium will be 14 l n /min at maximum output signal. Table 2. Conversion factors for thermal mass flow instruments. Gas type Conversion factor compared to N 2 Air 1.0 He 1.4 Ar 1.4 O 2 1.0 H 2 1.0 CO 2 0.76

The formula for the Conversion factor is given by: Conversion factor = ρ n1 cp1 / ρ n2 cp The indices 1 and 2 are for gas 1 and gas 2. 2 [2] Remark: Formula 2 is an approximation, it is derived from formula 1. For higher accuracy, non-linear terms have to be taken into account. 3. LAMINAR FLOW ELEMENT The standard thermal gas mass flow meter is of a bypass construction. The sensor is on the bypass leg as seen in Figure 2: Schematic cross view of thermal gas flow meter. The laminar flow device is a shunt. The flow sensor is made of a long, thin capillary tube, see chapter 1, therefore, the flow through this sensor will be laminar. If the flow through the laminar flow element is also laminar, then the ratio between the two flows can be considered constant for all flow rates. Therefore, the flow measured by the flow sensor is a ratio of the flow through the flow meter. Changing the capacity of the flow element will change the capacity of a flow meter. An example of such a flow element is given in figure 5. The flow is forced through numerous tiny channels, which have a typical capacity of 10 ml n /min (of Air) at 35 mbar. The capacity of the flow element (and consequently of the flow meter) can be set by choosing the number of flow elements, each containing a specified number of channels. In this way, flow instruments can be manufactured from 10 ml n /min up to 1000 l n /min and even higher using a single type of sensor. 1 3 2 5 4 Figure 5. The assembly of a laminar flow element. 1. Cross-section of a laminar flow disk. 2. Front view of a laminar flow disk. 3. End plate. 4. Assembly of a stack of disks. 5. Cross section of the stack and flow path. A different type of flow element is used for very low P applications. In figure 6, such an insertion type flow element is shown. The fluid is forced through an orbital channel. The typical pressure drop of this type of flow element is smaller than 1 mbar. The dimensions h and D can be varied for different flow rates. The main cause for malfunction of thermal mass flow instruments is pollution. The instruments contain very tiny channels, so they are very sensitive for dirt. Therefore, filters are recommended for any application other than clean, dry gases.

h L D Flow Figure 6. Low- P type flow element. 4. FLOW CONTROL VALVE The most frequently used control valves on mass flow controllers are the electromagnetic type. In figure 7, a cross section of a typical example of such a valve is shown. A plunger on top of an orifice controls the flow. The plunger can be controlled at a certain distance above the orifice. The size of the orifice can be determined (calculated) from; mass flow, fluid, fore and back pressure and temperature. This can be calculated by the Kv-factor. Where: Φ vn = flow [m 3 n /h] p 1 = supply pressure [bara] p 2 = downstream pressure [bara] p = pressure difference (p 1 - p 2 ) [bara] T = temperature [K] ρ n = density [kg/m 3 n ] K v Φvn ρ n T = 514 p p 2 [3] The orifice diameter can be determined by: d = 7.6 K [ mm] Typical orifice diameters used in gas flow controllers are d= 0.05 mm to d= 2 mm. v [4] Coil Spring Plunger Orifice In Out Figure 7. Cross-section of a flow control valve.

5. ELECTRONIC CIRCUITRY In figure 8, a schematic layout of the most important functions of the electronic circuitry is shown. The main functions are: Power supply and readout of the sensor bridge, Linearization of the sensor signal, Amplification of the sensor signal, Signal conditioning for various output signals, Temperature compensation., Flow control by means of the control valve. Vsupply Rup Rdown Gain Display Linearization Setpoint - + Valve Controller Sensor bridge Figure 8. Schematic layout of the main functions of the electronic circuitry of a thermal mass flow controller. Digital Electronics Gas mass flow controllers with digital circuitry are becoming more common. The digital electronic pcboard has a microprocessor on board and has an extra connector for (seral) communication. Although a number of the functions are still analog, this circuitry has interesting new features. A flow meter/controller can be provided with a number of pre-calculated conversion factors, including nonlinearity, so that the flow controller can be used for different gases. Remark: Beware that a thermal flow controller is optimized for the gas that it was built for; using a different gas in the instrument can reduce the performance. Other features of the digital flow controller are; identification, self check, easy communication via the computer, higher accuracy from polynomial calibration and optimization of the dynamic response of the controller. Some practical specifications: Commonly applied power supply: +/- 15 V, single rail power supply 15 V or 24 V. Output signal options: 0-5 V, 0 10 V, 4 20 ma and 0 20 ma.

6. LIQUID FLOW METERING About 10 years ago, the first version of the liquid flow meter based on the thermal measuring principle was developed. This measuring principle is very well suited for small and very small liquid flows (2 to 100 g/h). Only a few of the manufacturers of thermal gas mass flow instruments have a liquid mass flow meter in their product line. In figure 9, Cross-view of Liquid Flow meter a typical instrument is shown. In this construction, all the flow goes through the sensor; there is no bypass. The bypass metering method is not suited for liquids. The method of measuring is basically the same as in the gas sensor, except the dimensions are totally different. Heaters Thermopile Pt-100 temperature sensors Flow Casted aluminium housing Stainless steel flowtube Figure 9. A schematic cross-section of the thermal liquid flow meter LIQUI-FLOW. The top of the U-shaped sensor tube is held at a constant temperature. The temperature difference between up- and down stream ( T) is proportional to the mass flow. This T signal is measured by a thermopile sensor with numerous (over 5000) thermocouples and amplified to 5 Volt output. The typical flow rates that can be measured and controlled with this design are 2-100 g/h, or 20-1000 g/h. A very special design has been developed for extreme low flows, 5-250 mg/h. This metering method can be combined with a flow control valve as a mass flow controller. Some practical aspects: The hot spot temperature is held only a few C above room temperature to avoid boiling of the fluid in the sensor. This sensor design is very robust allowing for pressure ratings up to 400 bar. All wetted materials are Stainless Steel. See also [1].

Direct Liquid Injection, DLI. The development of the Liquid flow controller for low flow rates has been stimulated a.o. by DLI. DLI is a method for measuring and vaporizing liquids without the use of a bubbler. A DLI-system has many advantages compared to bubbler systems [2]. A DLI-system consists of a way to control the liquid precursor and a device to evaporate the liquid. An example of such a system is displayed in figure 10: The Controlled Evaporation and Mixing system (CEM). Variations of DLI. In some systems, a pump, instead of a mass flow controller controls the liquid. MFC CONTROLLED EVAPORATOR MIXER Figure 10. CEM; Controlled, Evaporation and Mixing system. 7. CONCLUSION Thermal mass flow meters and controllers for gases and liquids play a key role in modern CVD processes. The technology is well proven and accepted by industry, with hundreds of thousands of instruments in use world wide on a wide variety of processes. They are highly accurate, stable and offer virtual immunity to temperature and pressure changes in the fluid. Mechanically, they are compact, reliable and simple to install and operate. New and novel advances in design and applications viz. DLI, mean that the installed user base is increasing rapidly. References: [1] Ir. H.J. Boer, Ing. W. Derks. A precision thermal mass flow sensor for (very) small liquid flows, proceedings Volume IV, CE-Expo, Houston Texas 3 & 4 june 1998. [2] H.J. Boer. Mass Flow Controlled Evaporation System, Journal De Physique IV, Colloque C5, supplement au Journal de Physique II, Volume 5, juin 1995. pp C5-961 - C5-966.