ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.



Similar documents
IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus RTU master

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX - LON

Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX LG Air Conditioning

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

KNX Panasonic Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox ASCII Server - LON

IntesisBox KNX Mitsubishi Heavy Industries AC

User manual Compact Web PLC WP240 series IEC-line

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

1 Serial RS232 to Ethernet Adapter Installation Guide

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

MODBUS TCP to RTU/ASCII Gateway. User s Manual

One Port Serial Server Users Manual Model ESP901, ESP901E

NetBiter webscada Modbus User Manual

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Application/Connection Examples

7.7 Ethernet Communication (AFPX-COM5)

Process Control and Automation using Modbus Protocol

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Inwall Room Temperature Unit

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

TX2123 RS485 TO ETHERNET ADAPTOR

Using IDENT M System T with Modbus/TCP

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

KNX IP Interface. Operating and installation manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IntesisBox. Making Building Automation go further. KNX EIB Products

PCS0100en Persy Control Services B.V. Netherlands

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Modbus Communications for PanelView Terminals

Industrial Bar Code Scanners

Optimize your simple machines... Modicon M218 Selection Guide

EMG Ethernet Modbus Gateway User Manual

APNT#1168 Modbus - Establishing Communications Hints

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

Using HyperTerminal with Agilent General Purpose Instruments

User Manual Revision English

Inwall 4 Input / 4 Output Module

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

DSA-1000 / PRT-1000 Device Server / Thermal Printer

Communication standards and Carel solutions

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

T3 Mux M13 Multiplexer

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Electronic Control Devices The European Product Catalogue 2007

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

iridium for Weinzierl KNX IP BAOS

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

LBNP RS-232/485/422 serial device server. User manual

Telephone- and leased line modem for industrial applications TD-36

Serial over Ethernet Device Server. User s Manual

Debugging Network Communications. 1 Check the Network Cabling

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

TSX ETY 110 Module 8

Table of Contents. Creating a VC1000 Network... 3

Follow these steps to prepare the module and evaluation board for testing.

TK800-Series Industrial GPRS / UMTS / LTE Router

Communication Controller with IP services for leased lines and wireless links Radio Activity S.r.l.

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Installation and operation manual

RS-232/422/485, Power over Ethernet

Modbus and ION Technology

Digital Marquee Series

Multi-Master DF1 Protocol User Guide

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

RAS-E. Industrial router & RAS server & firewall. User manual Document reference :

Z-TWS4. Multifunction Straton / LINUX Controller.

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Network Management Card

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Introduction: Implementation of the MVI56-MCM module for modbus communications:

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

ewon COSY 141 Installation Guide

SenseLink TM. End-Point Controller. Addendum

Technical Information POWER PLANT CONTROLLER

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

PBX DIGITAL TELEPHONE EXCHANGE MAINTENANCE GUIDE

Transcription:

IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master ModBus TCP Master ModBus RTU Modbus RTU RS232/RS485 Modbus TCP Ethernet IntesisBox Modbus Server KNX EIB Bus LinkBoxMB Configuration Software Only needed for configuration IntesisBox acts as one more device into the KNX system, maintaining always in memory an updated mirror of the KNX points declared in its configuration table, ready to be served to Modbus when requested. Points in KNX can be read and written from a Modbus master device. Modbus interface of IntesisBox supports Modbus TCP or Modbus RTU (RS232 or RS485), software configurable, and acts as a Modbus slave device. The IntesisBox's KNX TP-1 (EIB) interface connects directly to the EIB bus and is optoisolated from the rest of internal electronics. When starting-up or after an EIB bus reset, IntesisBox can read into KNX the current values for those points required (critical signals needed to be updated in every moment in Modbus). This is configurable per point. More than one EIB group address can actuate on the same IntesisBox's point. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxMB, a Demo project for integration of KNX systems is also installed, using this demo project makes the engineering needed for this integration easy and quick.

IntesisBox capacity Element Basic Extended Notes version version KNX (EIB) groups 500 3000 Maximum number of different KNX group addresses that can be defined. KNX (EIB) listening addresses 1000 1000 Maximum number of different KNX group addresses that can be defined as listening addresses, one or more of these listening addresses can be assigned to each point. With this, more than one KNX group address can actuate on the same IntesisBox's point. There are two different versions of IntesisBox Modbus Server - KNX with different capacity every one of them: Basic version with capacity of 500 points. Ref. IBOX-MBS-KNX-A. Extended version with capacity of 3000 points. Ref. IBOX-MBS-KNX-B.

Sample applications Integration of KNX and Modbus using IntesisBox Modbus Server - KNX gateway. Modbus TCP master Modbus TCP Ethernet KNX bus Modbus TCP master LAN TCP/IP IntesisBox Modbus control system Building Management Systems (BMS). SCADA packages. Human Machine Interfaces (HMI). Direct Digital s (DDC). Programmable Logic s (PLC). Typical KNX (EIB) devices Lighting/blind control systems Building Automation devices. Home Automation devices. MODBUS System monitoring / controlling Full monitoring and control KNX/EIB System under monitoring / control

Typical applications Integration of KNX based lighting control into Building Management Systems "talking" Modbus SCADA Ethernet Modbus TCP Main Main Switches Sensors Field Field IntesisBox Actuators Dimmers Field KNX based Lighting Control Modbus based Building Control MODBUS TCP / RTU IntesisBox full integration

Modbus interface of IntesisBox Functions supported Modbus functions 03 and 04 (read holding registers and read input registers) can be used to read Modbus registers. Modbus functions 06 and 16 (Single Multiple Holding Registers and Write Multiple Holding Registers) can be used to write Modbus registers. If poll records are used to read or write more than one register, it is necessary that the range of addresses requested contains valid addresses, if not the corresponding Modbus error code will be returned. Modbus error codes are fully supported, they will be sent whenever a non valid Modbus action or address is required. Data Formats The Modbus registers can be of 2 bytes (16 bits) or of 4 bytes (32 bits). For 2 bytes (16 bits) registers, its content is expressed always in MSB..LSB. For 4 bytes (32 bits) registers, its content (the way IntesisBox handles the byte order) can be one of 3 different options, configurable, this has been implemented to avoid problems reading 32 bits registers, because Modbus master systems handle differently byte order of 32 bits registers depending on manufacturer/device. Modbus data coding formats supported 16 bits unsigned 16 bits signed 16 bits signed * 10 32 bits unsigned 32 bits signed 32 bits float Modbus RTU Baud rate can be selected from 1200, 2400, 4800, 9600, 19200, 38400 and 56700. (Data Bits: 8, parity: none, Stop Bits: 1). Modbus slave number can be configured. Physical connection (RS232 or RS485) can also be selected. Only the lines RX, TX and GND of the RS232 connector are used (TX/RX+ and TX/RX- for RS485). Modbus TCP The TCP port to use can be configured (by default 502 is used). The IP address, subnet mask and default router address to use by IntesisBox can be also configured. Address Map The Modbus address map is fully configurable, any point in the IntesisBox can be freely configured with the desired Modbus register address.

KNX interface of IntesisBox IntesisBox connects directly to the EIB bus (KNX TP-1) thanks to its internal EIB bus coupling unit, and acts as one more device of the KNX system with the same behavior and configuration characteristics. Internally, the bus coupling circuitry is opto-isolated from the rest of the electronics of the device to prevent damage of all the system in case of electrical pulse or over-voltage coming from the EIB bus. IntesisBox manages all the communication with the EIB bus according to its configuration. On receiving read requests from KNX, if they are destined to the KNX groups associated to internal points, the gateway updates its point s values in memory, ready to be served to Modbus when requested. When a change in a configured Modbus point is received, the corresponding write request will be sent to KNX, to the associated KNX group of the point (only if the point is configured to do so, this means if the point is configured as T - Transmit). IntesisBox continuously checks the status of the KNX bus, if a bus loss is detected, due to a bus power failure for example, on restoration of the bus IntesisBox will re-transmit the status of all the groups configured as T (transmit) and also will perform the Updates for the groups configured as U or U2. Every point defined in IntesisBox has the following KNX features associated to it: Feature Description EIS (DataPoint) * KNX data type to encode the signal s value. It will depend on the Modbus type of signal associated to it in every case. Group * It's the EIB group address associated to the point. It is also the EIB group to which will be applied the reading(r), writing (W), transmit (T) and update (U or U2) features. It's the EIB sending group or main group. Listening addresses These are the EIB group addresses that will also actuate on the point, apart of the main EIB group address mentioned above. R Read. If this flag is activated means that this point accepts read requests from KNX. W Write. If this flag is activated means that this point accepts write requests from KNX. T Transmit. If this flag is activated means that when the value of this point changes in the gateway, a write request will be sent to KNX indicating the new value for this EIB group. U or U2 Update. If flag U is activated means that when the gateway starts up or after an EIB bus reset, a KNX read request will be sent to KNX (of the main EIB group), then the received value will update the point s value in the IntesisBox s memory as it would happen for a normal write of this EIB group from KNX. If flag U2 is activated means that when the gateway starts up or after an EIB bus reset, a KNX read request will be sent to KNX (of the first EIB group listening address defined), then the received value will update the point s value in the IntesisBox's memory as it would happen for a normal write of this EIB group (the first listening address defined) from KNX. * Configuration for this feature is mandatory. All the mentioned flags (R,W,T,U,U2) related to the KNX part are configurable per point in the IntesisBox. KNX EIS (Datapoints) supported Switching (1 bit). Dimming (4 bits). Float (16 bits). Scaling (8 bits). Drive control (1 bit). Priority (2 bits). Float IEEE (32 bits). Counter (8 bits). Counter (16 bits). Counter (32 bits). ASCII char (8 bits).

Configuration tool LinkBoxMB Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the gateway s parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox Modbus Server series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Modbus Server series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox Modbus Server series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ).

Technical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Color Light Grey. RAL 7035. Power 9 to 30Vdc +/-10% 1.4W. 24Vac +/-10% 1.4VA. Plug-in terminal block for power connection (2 poles). Mounting Surface. Wall. DIN rail EN60715 TH35. Modbus RTU ports 1 x Serial RS232 (DB9 male DTE). 1 x Serial RS485 (Plug-in screw terminal block 2 poles). Modbus TCP 1 x Ethernet 10BT RJ45. KNX port 1 x KNX TP1 (EIB) port opto-isolated. Plug-in terminal block (2 poles). LED indicators 1 x Power. 2 x Serial port (Modbus RTU) activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). 2 x KNX port activity (Tx, Rx). 1 x KNX programming/bus. 1 Push buttons 1 x KNX programming. 1 Console port RS232. DB9 female connector (DCE). Configuration Via console port. 2 Firmware Allows upgrades via console port. Operational -40 C to +70 C temperature range Operational humidity 5% to 95%, non condensing range Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 2 Not operational for the moment. Reserved for future use. Along with the device it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM port. The configuration software LinkBoxMB, compatible with MS Windows operating systems, is also supplied.

Dimensions Power + Ethernet port KNX port Modbus RTU RS232/485 58 mm Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm 115 mm 130 mm