Energy from Waste Combined Heat and Power Facility, North Yard, Devonport. Community Ambient Air Quality Monitoring Programme Report Quarter 4, 2015



Similar documents
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

SUBCHAPTER 2D - AIR POLLUTION CONTROL REQUIREMENTS SECTION 2D DEFINITIONS AND REFERENCES

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Analysis One Code Desc. Transaction Amount. Fiscal Period

Case 2:08-cv ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8

Air Quality Monitoring at Dublin Airport: Annual Report HSSE Department

Enhanced Vessel Traffic Management System Booking Slots Available and Vessels Booked per Day From 12-JAN-2016 To 30-JUN-2017

Air Quality: Public Health Impacts and Local Actions

Iowa Fine Particulate Monitoring Network Design Values Iowa DNR Ambient Air Monitoring Group

EMISSIONS OF AIR POLLUTANTS IN THE UK, 1970 TO 2014

BCOE Payroll Calendar. Monday Tuesday Wednesday Thursday Friday Jun Jul Full Force Calc

Pollutant Exposure on Upper Floors: Implications for AQMAs

P/T 2B: 2 nd Half of Term (8 weeks) Start: 25-AUG-2014 End: 19-OCT-2014 Start: 20-OCT-2014 End: 14-DEC-2014

P/T 2B: 2 nd Half of Term (8 weeks) Start: 26-AUG-2013 End: 20-OCT-2013 Start: 21-OCT-2013 End: 15-DEC-2013

P/T 2B: 2 nd Half of Term (8 weeks) Start: 24-AUG-2015 End: 18-OCT-2015 Start: 19-OCT-2015 End: 13-DEC-2015

2) Relevance for environmental policy ) Data sources and reporting ) References at the international level... 6

C E R C. Cambridge Environmental Research Consultants. Air Quality Modelling for the London Borough of Islington. Final Report. 14 th January 2015

2014 Aamjiwnaang Air Monitoring Station Results. Ministry of the Environment and Climate Change April 19, 2016

Human Resources Management System Pay Entry Calendar

Effectiveness of air quality measures in Stockholm

CARBON THROUGH THE SEASONS

Ashley Institute of Training Schedule of VET Tuition Fees 2015

Direct Fresh Air Free Cooling of Data Centres

Coordination and air quality monitoring during emergencies. Colin Powlesland Environment Agency

BS EN Energy Management Systems VICTORIA BARRON, PRODUCT MARKETING MANAGER, BSI

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

CENTERPOINT ENERGY TEXARKANA SERVICE AREA GAS SUPPLY RATE (GSR) JULY Small Commercial Service (SCS-1) GSR

Source Apportionment Strategies for Atmospheric Particulate Matter in Mega-Cities

What are the causes of air Pollution

Pearl River Delta Regional Air Quality Monitoring Network

Detailed guidance for employers

BMBF China-Germany Workshop Garmisch Partenkirchen, 20 th -21 fst September 2009

Accident & Emergency Department Clinical Quality Indicators

Adjusted Estimates of Texas Natural Gas Production

Coffee prices fall to 18-month low as supply concerns fade

Clear the Air. What s in the air? Mix & match. Make a pie chart. The shape of the land. Exploring our winter weather. How PM 10.

Electricity Supply. Monthly Energy Output by Fuel Type (MWh)

ACCESS Nursing Programs Session 1 Center Valley Campus Only 8 Weeks Academic Calendar 8 Weeks

ACCESS Nursing Programs Session 1 Center Valley Campus Only 8 Weeks Academic Calendar 8 Weeks

Example of a diesel fuel hedge using recent historical prices

Implementing Carbon Reduction Without Impacting Working Capital. Presented by Dylan Crompton

Computing & Telecommunications Services Monthly Report March 2015

Resource Management Spreadsheet Capabilities. Stuart Dixon Resource Manager

University-Wide Academic Calendar

Comparison of PM10 and SO 2 Concentrations in the Cities Located at the Mediterranean Coast of Turkey

Pearl River Delta Regional Air Quality Monitoring Network

UK Air Quality Monitoring Networks

2.1 The Committee note and comment on the report. 3 DIRECTORATE OF DEVELOPMENT AND ENVIRONMENT PERFORMANCE

ITD Help Desk Traffic Report May 2002

Climatography of the United States No

Emission report Honda accord/cu1

Waste Management. Sunny Mistry. Rensselaer Polytechnic Institute. Solid and Hazardous Waste Prevention and Control Engineering. Spring 2014 MANE-6960

Q Environmental Emissions Data for Pickering Nuclear ONTARIO POWER GENERATION ONT

CAFIS REPORT

Experimental study on atmospheric pollutant emissions from heating systems, in Italy

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

REGIONAL DISTRICT OF NORTH OKANAGAN REQUEST FOR QUOTATION NO E

36.0 EMERGENCY REGULATIONS

Climatography of the United States No

Consumer ID Theft Total Costs

Electric Market National Overview

NASDAQ DUBAI TRADING AND SETTLEMENT CALENDAR On US Federal Reserve Holidays, no settlements will take place for USD.

Lower Hunter Ambient Air Quality Review of Available Data

Detailed Assessment of Air Quality on the A420 in Warmley for South Gloucestershire Council

Academic Calendars. Term I (20081) Term II (20082) Term III (20083) Weekend College. International Student Admission Deadlines

Natural Gas Wholesale Prices at PG&E Citygate as of November 7, 2006

Performance Measures. First Quarter 2012

Met Office. Observations Supply. Marine Networks

Air Quality in San Diego 2013 Annual Report

University-Wide Academic Calendar

University-Wide Academic Calendar

PM10 modeling for the city of Klagenfurt, Austria

2016 Dry Cleaning Compliance Calendar

Air quality and biomass installations. A briefing for local authorities

Managing Cattle Price Risk With Futures and Options Contracts

Monitoring of air pollution spread on the car-free day in the city of Veszprém

Sage ERP MAS 90, 200, 200 SQL, and Sage ERP MAS 500. Supported Versions

Grid Operations and Planning

Impacts of air pollution on human health, ecosystems and cultural heritage

Industries Association. ERCOT Successes and Challenges

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX

Cambridge Environmental Research Consultants Ltd

End of Life Content Report November Produced By The NHS Choices Reporting Team

Coffee Year Futures Trading Analysis

Start Your. Business Business Plan

Departures to the south from Runways 16L and 16R.

CSP. Feranova Reflect Technology. klimaneutral natureoffice.com DE gedruckt

Proposal to Reduce Opening Hours at the Revenues & Benefits Coventry Call Centre

Report on Progress Towards Meeting the Canada-wide Standards for Particulate Matter and Ozone in Alberta

Boston Traffic Management Center Activity Report for FY 2013 Real-time Traffic Signal Adjustments

New York dairy manure management greenhouse gas emissions and mitigation costs ( ) Jenifer L. Wightman and Peter B.

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

BOUNDARY DAM CCS CROSSES THE FINISH LINE. October 2014

Your guide to electricity pricing in Ontario

2015 Annual Network Plan and Assessment For Ambient Air Monitoring

Applying ICT and IoT to Multifamily Buildings. U.S. Department of Energy Buildings Interoperability Vision Meeting March 12, 2015 Jeff Hendler, ETS

AIR QUALITY IN GUERNSEY SCREENING AND ASSESSMENT DOCUMENT

Abstract. 1 Introduction. 2 Sampling locations

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Transcription:

Energy from Waste Combined Heat and Power Facility, North Yard, Devonport Community Ambient Air Quality Monitoring Programme Report Quarter 4, 2015

Overview of Monitoring Programme MVV started ambient air quality monitoring in the vicinity of the EfW CHP Facility in August 2014. Two pollutants are measured in the on-going survey, Nitrogen Dioxide (NO2) and particulate matter (as PM10). Monitoring of NO2 is carried out at ten locations in the area, while a PM10 real time monitoring station has been installed in the vicinity of Camels Head junction and began monitoring in October 2014. Nitrogen Dioxide Oxides of nitrogen (NOX) are formed at the high temperatures and pressures found within vehicle engines and other combustion processes. Some of the nitrogen in the air and the fuel, mainly in the form of nitric oxide (NO), is oxidised to form NO2 in the atmosphere. NO2 is associated with adverse effects on human health and it is this pollutant for which air quality standards have been set in the UK and elsewhere within the EU. Diffusion tubes are used to measure levels of NO2 within an area. These are small plastic tubes containing a chemical absorbent which reacts with NO2 present in the air. The tubes are changed each month and then sent away to a laboratory for analysis. The results give a NO2 level for each calendar month and these are used to derive an annual average which can be compared against the National Standards annual average air quality objective. Particulate Matter Particulates, alternatively referred to as particulate matter (PM), are tiny solid particles or liquid droplets suspended in a gas. Sources of particulate matter can be man-made or natural. Concentrations of particulate matter within the air can be expressed in terms of their size, for example PM10 represents particles of 10 µm diameter or less. PM10 occurs naturally, originating from volcanoes, dust storms, forest and grassland fires, living vegetation and sea spray. Human activities also generate PM10, from sources such as road transport, power plants, agriculture, various industrial processes and local domestic heating. A specialised air quality monitoring unit measures small particles of matter as they as drawn into the machine. The dust particles pass through a light, from a long life LED source, and as they do so generate a scattered light impulse. Measuring the deflection and intensity of this light impulse allows the size and number of particles to be detected. Measurement is continuous and a result is generated every five minutes. These results allow a daily average to be generated from which an annual average can be determined, both of these figures can then be compared to the National Standards. Locations The NO2 monitoring sites have been divided between the area around the Camels Head junction (which could potentially be affected by emissions from site-related road traffic) and other locations representative of the urban background in St Budeaux and King s Tamerton (which could be affected by emissions of NO2 from the main chimney of the EfW CHP Facility). The PM10 real time monitor is located in the vicinity of Camels Head junction. 2 P a g e

National Standards The national air quality objective values, against which the monitoring results are compared, are shown in the Table below: AIR QUALITY OBJECTIVES SET IN UK REGULATIONS Pollutant Averaging Period Objective Value ( g/m 3 ) Maximum Permitted Exceedances Nitrogen dioxide(no2) Annual average 40 None Hourly average 200 18 hours per year Particulate matter(pm10) Annual average 40 None Daily average 50 35 days per year 3 P a g e

2015 Quarter 4 This quarterly update presents the results of monitoring carried out during October, November and December 2015. 1. Operational or Other Activity During this time, the EfW CHP facility was operational. 2. NO2 Diffusion Tubes Oct: 10 tubes deployed 02/10/2015, 10 recovered 11/11/2015, date of report 25/11/2015 Nov: 10 tubes deployed 11/11/2015, 10 recovered 07/12/2015, date of report 16/12/2015 Dec: 10 tubes deployed 07/12/2015, 10 recovered 06/01/2016, date of report 25/01/2016 3. PM10 Monitor maintenance, service or down time Monitor fully operational, except during service. No service or down time during this reporting period. 4 P a g e

Concentration (µg/m 3 ) 4. NO2 Diffusion Tube Monitoring Note: Results shown include an adjustment for laboratory blank but are provisional until bias adjustment has taken place. Three Monthly Monitoring. The results of the monitoring for the three-month period October to December 2015 are shown in the graph below. Monthly NO 2 concentration 60 50 Oct-15 Nov-15 Dec-15 40 30 20 10 0 Camels Head Junction (T1) Carlton Terrace (T2) Weston Weston Mill School Mill School (T3) (T4) Erith Avenue (T5) York Road (T6) Cardinal Avenue (T7) Ferrers Road (T8) Roman Way (T9) Kelly Close (T10) Summary of Results A summary of results to date are shown in the Table below where the rolling 12-month average can be directly compared with the Annual Air Quality mean objective. The mean concentrations of all results to date are seen to be within the air quality objective of 40 µg/m 3 at all the monitoring sites. 5 P a g e

NO 2 MONITORING Monthly NO 2 Concentration ( g/m 3 ) 2015 Location Description Jan-15 Feb-15 Mar-15 Apr-15 May-15 Jun-15 Jul-15 Aug-15 Sep-15 Oct-15 Nov-15 Dec-15 2015 Average Average to date T1 Camels Head Junction 30.03 29.93 27.57 28.5 23.97 23.32 24.97 21.91 25.10 29.93 24.89 27.04 26.43 26.70 T2 Junction of Weston Mill Drive & Carlton Terrace 21.88-22.49 21.73 15.24 15.52 16.28 15.59 22.67 24.06 16.44 16.81 18.97 20.70 T3 Weston Mill School 24.40 24.23 20.04 17.5 15.87 15.5 17.54 16.50 18.94 22.12 17.29 15.99 18.83 19.94 T4 Weston Mill School 24.38 24.44 22.37 20.86 16.85 14.74 17.03 15.35 19.71 23.11 18.12 15.35 19.36 20.19 T5 Erith Avenue 37.30 38.07 29.73 28.54 28.43 27.88 28.43 27.35 34.26 33.15 29.15 22.47 30.40 31.22 T6 York Road 16.62 15.93 14.25 15.06 10.18 10.52 9.27 10.95 14.36 18.05 11.97 11.1 13.19 13.98 T7 Cardinal Avenue 16.97 20.09 17.52 15.63 9.74 11.11 10.77 10.24 13.51 19.44 12.87 10.9 14.07 15.36 T8 Ferrers Road, St Budeaux 16.28 17.28 15.46 16 9.16 10.44 8.89 11.07 14.81 17.15 12.14 13.33 13.50 14.36 T9 Roman Way, adjacent to Plaistow Hill Infant and Nursery School 28.14 28.42 28.17 28.29 20.02 23.91 21.76 23.35 28.32 30.43 21.51 21.75 25.34 25.73 T10 Kelly Close, Barne Barton 12.27 15.6-14.23 7.98 9.64 10.19 10.09 12.61 18.05 8 9.17 11.62 12.32 Key Air quality standard not exceeded Air quality standard exceeded Annual rolling averages 01/07/2015 01/08/2015 01/09/2015 01/10/2015 01/11/2015 01/12/2015 T1 Camels Head Junction 27.71 27.49 26.97 26.54 26.10 26.43 T2 Junction of Weston Mill Drive & Carlton Terrace 21.22 21.16 20.84 21.03 19.95 18.97 T3 Weston Mill School 20.38 20.31 20.14 20.05 19.37 18.83 T4 Weston Mill School 20.76 20.44 20.41 20.31 19.83 19.36 T5 Erith Avenue 32.26 32.01 32.15 31.96 31.21 30.40 T6 York Road 13.78 13.93 14.04 14.37 13.62 13.19 T7 Cardinal Avenue 15.72 15.61 15.45 15.57 14.65 14.07 T8 Ferrers Road, St Budeaux 14.39 14.58 14.53 14.56 13.77 13.50 T9 Roman Way, adjacent to Plaistow Hill Infant and Nursery School 25.54 26.02 25.93 26.31 25.43 25.34 T10 Kelly Close, Barne Barton 12.41 12.59 12.52 12.91 11.81 11.62 6 P a g e

µg/m3 µg/m3 5. PM10 Monitoring Hourly PM10 Concentrations Hourly averages PM 10 at Wolseley Road / Weston Mill Drive Junction 2015 Q4 140 120 100 80 60 40 20 0 24-hour PM10 Concentrations Daily averages PM 10 at Wolseley Road / Weston Mill Drive Junction 2015 Q4 90 80 70 60 50 40 30 20 10 0 PM 10 24-hour average AQS annual average AQS daily average Summary of Results A summary of results to date are shown in the table below. The mean concentrations to date are seen, with one exception, to be within the AQS annual air quality mean objective of 40 g/m 3. The highest individual value was recorded in December, when the daily average for Sunday 27 th December exceeded the AQS 24-hour average of 50 g/m 3. This coincides with poor air quality across the whole of southern Britain, as verified by DEFRA: https://uk-air.defra.gov.uk/data/daqi-regional-data 7 P a g e

Once on their website, it is possible to select dates of interest to check local and national data. A description of the colours is given in their air pollution index. Actual chimney emission data for our Facility is published weekly on our website: http://www.mvvenvironment.co.uk/en/swdwp_devonport/links_and_downloads/links_and_downloads.jsp Data capture for October, November and December 2015 was 100%. PM10 MONITORING AT THE CAMELS HEAD JUNCTION Results October - December 2015 Minimum recorded value (µg/m 3 ) 0.906 Maximum recorded value (µg/m 3 ) 121.5 Average (µg/m 3 ) 15.527 Standard deviation (µg/m 3 ) 11.322 Data Capture (%) 100 Number of 24-hour periods with average above 50 (µg/m 3 ) 1 Summary Rolling average (all months) (µg/m 3 ) 12.485 Rolling average (last 12 months) (µg/m 3 ) n/a Average 15.23 2014* Number of 24-hour periods with average >50 (µg/m 3 ) 0 Average 12.615 2015 Number of 24-hour periods with average >50 (µg/m 3 ) 1 2016 Average Number of 24-hour periods with average >50 (µg/m 3 ) 2017 Average Number of 24-hour periods with average >50 (µg/m 3 ) Key: Air quality standard not exceeded Air quality standard exceeded * 14 th October - 31 st December 2014 only 8 P a g e