Protecting data centers from seismic activity Understanding enclosure standards is critical to protecting equipment



Similar documents
Key Considerations for Selecting Server Cabinets for Seismic Areas

The Fundamentals of Seismic Compliance and Heating, Ventilation and Air-Conditioning Systems (HVAC)

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication

6 RETROFITTING POST & PIER HOUSES

SEISMIC TESTING OF NON-STRUCTURAL COMPONENTS AND ASSESSMENT OF THE PRESCRIBED RESPONSE SPECTRUM

SEISMIC EVALUATION OF HOSPITAL PIPING SYSTEMS

Critical Facility Round Table

Wisconsin Building Products Evaluation

Chapter 3 Pre-Installation, Foundations and Piers

FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS

Chapter 5 FLOOR LOADING AND WEIGHTS

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

ICC-ES Evaluation Report

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Herschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -

Earthquakes and Data Centers

Review of Code Provisions on Design Seismic Forces for Liquid Storage Tanks

MANUFACTURED HOUSING USED AS DWELLINGS

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Active Vibration Isolation of an Unbalanced Machine Spindle

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Cisco Nexus 7000 Series.

Field Application Note

CH. 2 LOADS ON BUILDINGS

Contractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

SPCC Plan - Calculation Guidance

Facilities Development Division. The Building Department for California s Hospitals

Untopped Precast Concrete Diaphragms in High-Seismic Applications. Ned M. Cleland, Ph.D., P.E. President Blue Ridge Design, Inc. Winchester, Virginia

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE

Vibration Isolation in Data Centers

Design for Nonstructural Components

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

What is Seismic Retrofitting?

Seismic Assessment of Engineering Systems in Hospitals A Challenge for Operational Continuity

SFI SPECIFICATION EFFECTIVE: FEBRUARY 26, 2014 *

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

Detailing of Reinforcment in Concrete Structures

Design Example 1 Design Spectral Response Acceleration Parameters 11.4

HAS SERIES Air Suspensions

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

AUTOMATIC SWINGING DOOR

How to Design Helical Piles per the 2009 International Building Code

AMF112 Instruction Manual

Specification for Structures to be Built in Disaster Areas

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Seismic Analysis and Design of Steel Liquid Storage Tanks

Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Guidelines for Earthquake Bracing Residential Water Heaters

QUANTITATIVE RISK ASSESSMENT FOR ACCIDENTS AT WORK IN THE CHEMICAL INDUSTRY AND THE SEVESO II DIRECTIVE

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

How To Build A T7 Rack For Information Technology

Cover. When to Specify Intermediate Precast Concrete Shear Walls Rev 4. White Paper WP004

data center rack Ordering & Installation Guide we simplify networksṭm

Seismic Risk Prioritization of RC Public Buildings

SITE SPECIFIC WIND TURBINE FOUNDATION CERTIFICATION

Submittal Information

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

Seismic Data Requirements for Eaton UPS Equipment Installation

Drum-Set Tuning Guide

SEISMIC APPROACH DESIGN COMPARISON BETWEEN

System Integration. System Integration. Global Manufacturing

Residential Deck Safety, Construction, and Repair

SEISMIC RETROFIT DESIGN CRITERIA

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

On Quality Enhancement in Seismic Testing Laboratories based on Efficient IT Infrastructure Deployment

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

AMF112 ( <00>) 13mm (1/2 in.)

A COMPUTER ANALYSIS OF THE VINCENT THOMAS SUSPENSION BRIDGE

Stability. Security. Integrity.

The Calculation of G rms

DESIGN DRIFT REQUIREMENTS FOR LONG-PERIOD STRUCTURES

Interim Staff Guidance on Implementation of a Probabilistic Risk Assessment-Based Seismic Margin Analysis for New Reactors DC/COL-ISG-020

Guide to adhesively mounting accelerometers

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

DEPARTMENT OF BUILDING INSPECTION City & County of San Francisco 1660 Mission Street, San Francisco, California

Page & Turnbull imagining change in historic environments through design, research, and technology

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 3. Sine Sweep Frequency and Octave Calculations

Magnetic / Gravity Loading Analysis

ATI Evaluation Service A Division of Architectural Testing Certification Services

Cooktop Low-Profile Ventilation Hoods

Transcription:

Protecting data centers from seismic activity Understanding enclosure standards is critical to protecting equipment Author: Joel Young, engineer at Crenlo Abstract In the event of an earthquake, the type of enclosures used to house data center equipment is often the deciding factor in whether or not the equipment will remain active, and selecting the proper enclosure could mean the difference between failure and continued functionality. Most manufacturers of data center racks and enclosures offer products that are marketed as offering seismic protection ; however, there can be significant differences in the standards used to achieve those labels, and thus, major disparities in the level of protection that those products provide. There are two standards by which enclosures are deemed seismic Telcordia Technologies GR-63-CORE Network Equipment Building Systems (NEBS) requirements and the International Building Code (IBC). While both serve an important purpose, many would argue that they are too different to apply the same label to a product. In order for a data center manager to select an enclosure that will offer the appropriate level of protection, he or she must have a firm grasp on NEBS and IBC requirements and understand how each corresponds to the level of protection offered by a particular enclosure. This white paper will discuss the history of each standard, explain the methods used to test and certify enclosures as compliant with each standard and outline how data center managers can select the best type of seismic enclosures for their applications. 1 P age

Protecting data centers from seismic activity When building a data center in a seismically active region, data center managers must select enclosures rated to protect their equipment in the event of an earthquake. With an abundance of options on the market, all being marketed as seismic enclosures, how does a buyer decide which product offers the right seismic solution for the application? Given the matching labels, the cost-conscious choice might seem prudent. However, before acquiring earthquake protection for critical data center equipment, data center managers should understand that all seismic-rated enclosures are not created equal. In fact, there can be significant disparities in the testing achievements behind manufacturers seismic labels and a corresponding variance in the caliber of earthquake protection provided to electronic equipment. There are two standards by which enclosures are deemed seismic Telcordia Technologies GR-63-CORE Network Equipment Building Systems (NEBS) requirements and the International Building Code (IBC). While both standards are often used to achieve the same label, one should not assume that all seismic enclosures offer the same level of protection, regardless of which standard was used for certification. In order for a data center manager to select an enclosure that will offer the appropriate level of protection, he or she must have a firm grasp on NEBS and IBC requirements and understand how each corresponds to the level of protection offered by a particular enclosure. To better understand the differences between the two standards, it is important to understand their origins. History In the years following AT&T s monopoly lawsuit, a flood of competitive local exchange carriers arose, bringing a set of new and varied network equipment to the once homogenous collection of AT&T equipment housed in central offices throughout the country. It quickly became apparent that there was a need for a standard to which network equipment had to adhere in order to ensure network compatibility and uptime. What came to be were the NEBS requirements, of which, section GR-63 applied specifically to protecting equipment in the event of seismic activity. Because of the essential nature of telephone communication service, GR- 63 requires that in the event of an earthquake, The equipment shall sustain operation without replacement of components, manual rebooting and human intervention. In other words, an enclosure must provide a level of protection such that the network remains active during an earthquake. 2 P age

Image: Bell Telephone Labs, using Emcor enclosures, circa the 1960s While GR-63 s history is based on preventing network downtime, IBC was formed as a broad collection of structural building requirements to prevent human injury and reduce equipment damage during an earthquake. Following the 1994 earthquakes in Los Angeles during which more than 40 percent of the $80 billion in damages were non-structural it became apparent there was a need to create guidelines for securing objects within buildings to the floors, walls or ceilings. In 2000, IBC was created as a guideline to which businesses must adhere in order to receive funding from the Federal Emergency Management Agency (FEMA) in the aftermath of an earthquake. In short, the IBC is a set of guidelines on how to mount objects, so that they do not tip over during an earthquake. With two very different origins, there are bound to be inconsistencies in what these standards measure, how they are measured and how they are applied. While GR-63 requirements and testing procedures are consistent across the board, IBC requirements are site-specific, and thus differ from city to city, state to state, building to building and floor to floor. So, not only are GR-63 and IBC inconsistent with each other, but there can be major inconsistencies from one IBC-compliant enclosure to the next. Many of these inconsistencies are related to the varying methods of calculation, testing and certification. 3 P age

Calculation, testing and certification To achieve GR-63 compliance, enclosure manufacturers turn to independent, thirdparty testing facilities. An enclosure is loaded to its capacity and mounted to a shaker table. The shaker table then simulates an earthquake, shaking in every potential direction at varying levels of intensity equivalent to an earthquake in a particular seismic zone Zone 1 is the least intense; Zone 4 is the most intense. Accelerometers are attached to the enclosure to measure its vibration and sway during the test. In order to pass the test and achieve the seismic rating, the enclosure must not sway more than 3 inches in any direction and all components must remain operable during and after the test. This test is the same for every manufacturer of an enclosure product, regardless of where that enclosure is going to be used or its intended purpose. The only difference between one GR-63- compliant enclosure and another would be the seismic zone to which it has been tested and deemed compliant. IBC compliance on the other hand, can be achieved through three different methods, each of which analyzes the enclosure and its contents as part of the entire building system, rather than analyzing the enclosure itself. The fact that there are three varying methods of arriving at the answer, however, is often confusing for a buyer. The most stringent of these three methods requires a shaker table test similar to the one used in GR-63 certification. In fact, in most cases, a GR-63-compliant enclosure would also be IBC-compliant for the simple fact that the acceleration used in a shaker table test for GR-63 is more intense than the waveform used in the ICC-ES AC156 shaker table test used to certify IBC compliance. The other two methods of calculating IBC compliance is where the confusion often lies one being a mathematical equation that compares potential seismic effects to objects mounted in a building and the other being the use of experience data. The latter would require the manufacturer to reference an enclosure s performance during a specific earthquake, and design the enclosure to the same specifications as the enclosure from the referenced event. The issue with this method is that there are a number of variables that are often difficult to account for with historical record, for instance, how the enclosure was mounted and loaded. The equation used to calculate IBC compliance utilizes the variables that are difficult to account for with experience data. These variables revolve around where and how the enclosure is being installed in order to arrive at the design horizontal seismic force (F p ) acting on the enclosure at its center of gravity. 4 P age

A value called the design spectral response (S DS ) is calculated based on site-specific variables, including the site soil classification factor (F a ), the maximum short-period ground accelerations (S S ) and the seismic design category, which ranges from Category A (the lowest risk of earthquake) to Category F (the highest risk of earthquake). S DS is calculated as the product of F a and S S multiplied by a factor of either 3 / 4 (for Category A) or 2 / 3 (for all other categories). The enclosure is also given a value called the component importance factor, which is either 1.0 or 1.5, depending on the type of building in which it will be mounted An enclosure mounted in an essential building such as a hospital, where uptime is critical is given the 1.5 value, whereas an enclosure mounted in a nonessential building is given the 1.0 value. The essential value would require that the electronics continue to function in the event of an earthquake whereas the nonessential value would simply require the enclosure to remain standing. The taller the building, the more flexible it becomes, which is why the amplification takes into account the height of the building and the height of the floor where the enclosure will be mounted. Lastly, the total weight of the loaded enclosure (W p ) is taken into account. The advantage to using this equation is that it accounts for all factors that could potentially affect an enclosure s ability to protect equipment from an earthquake, yet compliance using this method does not require physical testing, which can be costly, thus leading to a very affordable seismic-rated product. Crenlo s approach to seismic certification Crenlo offers two seismic products a line of Emcor seismic enclosures and the Emcor IBC kit. The Emcor seismic enclosures are GR-63-compliant enclosures meant for essential facilities, and the IBC kit is a hardware set that can be attached to existing enclosures for easy and affordable compliance with IBC in non-essential facilities. 5 P age

GR-63 testing Emcor seismic enclosures are available in three standard options the light-duty (400- pound capacity), the medium-duty (600-pound capacity) and the heavy-duty (800-pound capacity) each of which has been loaded to capacity and tested on a shaker table to meet seismic Zone 4 requirements. Seismic Zone 4 requirements are the most stringent of all, requiring that Crenlo s enclosures stay intact while experiencing the equivalent of an earthquake measuring up to 8.3 on the Richter scale. At Intertek a third-party test facility Crenlo s enclosures were tested to the standard GR-63 compliance test known as Waveform Test Procedure 5.4.1.5. The procedure tested side-to-side, front-to-back and vertical framework axes as follows: Crenlo s enclosures were subjected to low-level sine sweep to verify the resonance point was greater than 2 Hz, as outlined in requirement R4-48 of GR-63. The frequency was swept from 1 to 50 Hz at a sweep rate of 1.0 octave per minute, with an acceleration level of 0.2 g. Crenlo s enclosures were verified for functionality as outlined in requirement R4-50 and objective O4-49, and the physical condition was verified as described in requirements R4-46, R4-47, and R4-48 as well as objective O4-49. Crenlo s enclosures were subjected to the Zone 4 acceleration-time waveform, known as VERTEQII. A Test Response Spectra (TRS) was generated by analyzing the time domain acceleration data measured at the control accelerometer located on the shaker table. The TRS exceeded the Required Response Spectrum (RSS) for seismic Zone 4 in the range from 1.0 to 50 Hz. Crenlo s enclosures were thoroughly inspected, and all changes in physical condition were noted. The results show that Crenlo s enclosure is compliant with all requirements and objectives associated with the most stringent form of GR-63 for Zone 4 compliance. 6 P age

IBC calculation The Emcor IBC kit is available for mounting onto existing enclosures in order to achieve IBC compliance in non-essential facilities. The kit is mounted using four brackets attached to the floor to properly constrain the loads. The kit s compliance with IBC has been certified using the aforementioned equation as follows: The figure to the right shows the horizontal (H1, H2) and vertical (V) seismic forces acting at the center of gravity (COG). The resulting forces are shown in red and include the horizontal forces (R1, R2) and moments (M1, M2) at the base of the frame. These forces are transmitted to the support structure through the tie-down brackets and four Hilti KB-TZ concrete stud anchors which attach the four brackets to the floor. For nonstructural components, such as an enclosure, seismic design requirements stipulate that the force F p shall be applied independently independently in at least two orthogonal directions. Then, the maximum moment (either longitudinal or transverse) is used in the calculations. H1 and H2 are based on the seismic equation for F p. The vertical seismic force (V) is calculated as 0.2*S DS *W p. The moments are the horizontal seismic force F p * half the height of the frame. The shear load on the concrete anchors is calculated by the vector sum of the two horizontal loads. The tension load on the concrete anchors is calculated by combining the vertical force (V) with the couples, due to the two moments, M1 and M2. These calculations are used to help the structural engineer determine the appropriate length and tensile strength of the concrete anchors used to install the enclosure. Crenlo consults with the customer to make installation recommendations based on floor type, floor height, building height and weight of the loaded enclosure. 7 P age

Installation Regardless of which standard is used to certify a product and how stringently that standard is applied, an enclosure can only offer sufficient protection from seismic activity if properly mounted and loaded. IBC-compliant mounting is generally achieved through the certification of a building engineer. Crenlo works directly with customers and their engineers to recommend minimum requirements for bolt diameter and depth, as well as minimum compressive strength of the concrete floor. On the other hand, GR-63 requires that the bolts be a minimum of 3.5 inches long and 0.5 inches in diameter. These are the size of bolts used in testing procedures and thus, are meant to correspond to the real-world scenario. If a GR-63 enclosure also needs to be compliant with IBC, Crenlo can work with the customer and their engineer to determine installation requirements for compliance with both standards. When it comes to loading, IBC and GR-63 are actually quite similar. All the standard rules of physics still apply. It is important to remember that the lower the center of gravity, the more stable an enclosure will be. So, when loading to capacity, the heaviest items should be loaded toward the bottom and the lightest toward the top. Both standards account for weight, but it is the responsibility of the installer to ensure the weight be distributed as low as possible, as both standards assume. Conclusion Both standards serve an important purpose, but buyers often fail to recognize the differences between the two, which often leads to purchasing a product that isn t the best solution for the application. For buyers that require electronics to continue functioning throughout an earthquake, a GR-63 compliant enclosure will provide the best solution. For those buyers that need to be in compliance with IBC at a non-essential facility, but do not want to replace their existing enclosures (whether due to cost or convenience), an IBC kit that can easily be attached to existing enclosures is an easy and affordable solution. Regardless of the type of enclosure, it s important to consult with a structural or building engineer during installation in order to ensure the enclosure is properly installed in accordance with the standard being used. Furthermore, it s important for a buyer to select a manufacturer that has the knowledge and capabilities to determine which product is right for their application and has the knowledge to consult with a structural engineer regarding installation. Crenlo has the capabilities to consult with customers and deliver the product that best suits their needs, 8 P age

whether that means a standard, off-the-shelf product, a modification of a standard product or a completely custom solution. About Crenlo Crenlo, under their Emcor brand of enclosures, offers a versatile selection of consoles and enclosures, each of which can be modified and configured to meet the needs of almost any application. For those applications that fall outside of the standard lineup of Emcor products, Crenlo can design and build completely custom solutions to meet the needs of individual customers. For more than 60 years, top companies in the technology, aerospace, data communications, test and measurement, and defense industries have put trust in Crenlo and its Emcor brand of enclosures, to meet exact standards with highquality, dependable solutions for protecting electronic equipment. General inquiries Crenlo 1600 4 th Ave N.W. Rochester, MN 55901 507-287-3535 Media inquiries Two Rivers Marketing John Krantz jkrantz@2rm.com 515-557-2072 9 P age