OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter



Similar documents
The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o l / m i n. s. p. a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

GREAT BRITAIN CANADA MP FILTRI U.K.

Return line filters. Return line filters

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

15/40/80CN Series Medium Pressure Filters

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

HFS and HFD Series. High Flow Single and Duplex Filters Max l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

OLI. Oil level indicator

Turbine Flow Sensor Series VTR

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Duplex Filters 40 FLDK 0008(C)-0120(C)

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Hydraulic Control Solutions

Filter Elements E /05.06

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

Hydraulic Flow Control Valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

SQUARE D INDUSTRIAL CONTROL PRODUCTS

PUMP AND MOTOR DIVISION

3/2- and 2/2-way cartridge valve type BVE

Variable Displacement Pump AA10VSO

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

2/2 and 3/2 Way Size 6 Seat Valves

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

15/40/80CN Series Coreless Medium Pressure Filters

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

MEMBRANE VACUUM MINI PUMPS

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05


2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3/2-way Solenoid Valve, direct-acting, NC or NO

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Solenoid valves 2/2-way direct-operated Type EV210A

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Series TMM Axial Piston Motor. Technical Information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Safety at a high level!

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)


3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

How To Use A Flowmeter

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Radial piston pumps type R and RG

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Pressure transmitter For general industrial applications Model A-10

300 Series PA Pump and Cooler Assemblies

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

4 Posiflow Proportional Solenoid Valves

MANTA Piston Distributor for Oil and Fluid Grease

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

3/2 Solenoid Cartridge Valve, Size 6

Chapter 6: Check Valves

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

SOLENOID VALVES 3-4 WAY

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Working Pressure up to 630 bar / 9135 PSI

Pressure reducing valve, direct operated, Type ZDR 6 D

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Pressure regulating valve with modulating kit, type DRV

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Fixed displacement vane pumps

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Pressure relief valves Size 6

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Oil - kerosene burners

Plastic tube flowmeters Series PT/PS

Thermostatic valve Type AVTA

Series description: Wilo-Yonos MAXO-D

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Transcription:

D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from the reservoir. The SF2 250 filter uses a vacuum gauge or electrical vacuum switch for filter element indication. element to be replaced without having to drain the These filters are supplied complete with bypass valve. oil from the reservoir. These filters are particularly suitable for power pack, mobile, Unscrewing the filter cover operates a closing valve construction, and industrial machinery applications. COVER INDICATOR OPTIONS HEAD ELECTRICAL OUT FILTER ELEMENT. VISUAL BYPASS VALVE UNI EN ISO 9001 N 037/98 CUT OFF VALVE IN OPTIONAL MAGNET COLUMN ON REQUEST SF2 250 01040/5.99/UK. 2

MP Filtri - Filtration Technology Filter element: Materials End caps: Nylon Support tube: Steel Support frames: Expanded metal Element material Nominal filtration MSeries Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size). Filtering area Filter elements Type SF2 250 M25 M60 M90 M250 1980 1980 1980 1980 Values in cm 2 Filter body: Materials Head Pressure die cast aluminium Cover Nylon Seals A Series: Nitrile (Buna-N) V Series: Viton Indicator Brass Working temperature From -25 to +110 C For temperature outside this range, please consult our Sales Network Organization Bypass valve Setting pressure Bypass valve, differential opening pressure: 30 kpa ± 10% 3

MP Filtri - Specification Compatibility with fluids Filter head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO water-based emulsions (types HFAE-HFAS as per ISO synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO water-glycol (types HFC as per ISO Ask for anodised version Filter elements As per ISO 2943; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO For water-based emulsions (type HFAE-HFAS as per ISO and fluids other than those mentioned, please consult our Sales Network Organization. Seals A Series Nitrile (Buna-N) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO water - based emulsions (types HFAE-HFAS as per ISO V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO Types of indicator Visual indicator Description: SF2 250 series filters are fitted with visual and electrical indicators. V Series (radial) V0 Series (axial) vacuumeter: scale 0 76 cmhg vacuumeter: scale 0 76 cmhg Electrical indicator E1 Series: vacuum switch with change-over contacts (setting std. 20kPa ± 10%) (adjustable setting: 15 to 90 kpa) Operational information: Max voltage: 250 V 50 60 Hz Max current: 5 A resistive, 2 A inductive. Protection degree IP65 V0 V E1 ø 50 59 A/F 17 ø 40 65 30x30 Revolving 34 1/4 BSP 32 A/F 14 PG11 Cable entry gland 1/4 BSP 9 1/4 BSP A/F 19 4

Selection & installation information Filter elment types M Series Metal mesh media, available in 25, 60, 90, 250 micron Example - M25, M60, M90 and M250 Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 30 mm 2 /s (cst) with a maximum total filter assembly (housing and filter element) pressure drop of 8 kpa (0,08 bar). SF2 SERIES 250 SIZE 122 1/4 BSP 82 43 350 OUT 35.71 ± 0.2 SF2 250 Filter element M25 M60 M90 M250 Flow rate l/min option 1 * 100 100 100 100 Flow rate l/min option 1 1/4 * 140 145 150 150 Flow rate l/min option 1 1/2 140 150 160 160 ** Flow rates are based using a mineral oil fluid at 30 mm 2 /s. ** Weight including filter element Weight kg ** 2.7 D1 9 69.85 ± 0.2 380 ø 114 Thread connections Type A Type A G1 1 1/2 BSP G6 SAE 20 G2 1 1/2 NPT G7 1 BSP G3 SAE 24 G8 1 NPT G4 1 1/4 BSP G9 SAE 16 IN G5 1 1/4 NPT Flange connections 140 90 Type F1 A 1 1/2 SAE D1 M12 R 5,5 3000PSI/M F2 1 1/2 SAE 1/2 UNC 140 11 A A 3000PSI/UNC ø 150 ± 0.2 ø 165 ± 0.2 HOLES ON THE TANK 90 20,0 Filter housing pressure drop 1 SF2 250 1 1/4 45 15,0 1 1/2 IN p kpa 10,0 5,0 Ø 115 0,0 No. 4 Holes M10 0 25 50 75 100 125 150 175 200 Flow rate I/min Ø 150 min Ø 165 max 5

Pressure drop information General Pressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968 Filter assembly pressure drop - p Total = p Housing + p Filter element Housing pressure drop - The housing pressure drop is proportional to the fluid density Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check the fluid operating temperature and fluid type to obtain the working viscosity according to the following formula: p1 Filter element = (working viscosity/brochure viscosity) x p filter element Brochure viscosity = 30 mm 2 /s cst 1 bar = 100 kpa Filter assembly sizing example Selection Customer requires a 140 l/min filter assembly 1 1/2 port size Mineral oil fluid: ISO VG 46 (46 mm 2 /s (cst) at 40 C) M90-90 micron filtration Housing pressure drop - SF2 250 (1 1/2 port size) with 140 l/min p = SkPa (see curve on page 5) Filter element pressure drop (brochure viscosity) - SF2 250 M90 N with 140 l/min p = 1.4 kpa (see curve on page 6) Filter element pressure drop (working viscosity) - With 46 mm 2 /s (cst) p 1 = 0.6 x ( 46/30 ) = 1.1 kpa Filter assembly pressure drop p Total = p Housing + p 1 Filter element = S + 1.10 = 6.1 kpa* { * Acceptable pressure drop as per our recommendations Filter element pressure drop 2,0 1,5 SF 250 M25 M60 p kpa 1,0 0,5 M90 M250 0,0 0 25 50 75 100 125 150 175 200 Flow rate l/min p kpa 50,0 40,0 30,0 20,0 10,0 Bypass valve pressure drop SF2 250 0,0 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min 6

SF2 Ordering code example 250 A G1 H M25 V This example shows how order a filter assembly with features based on the customer request. 250 Nominal size Filter condition indicator S With threaded hole only T1 With hole + plug V0 Visual (axial vacuumeter) V Visual (radial vacuumeter) E1 Electrical (change-over contacts vacuumeter) Seals Filter elements A V Nitrile (Buna-N) Viton M25 M60 M90 M250 Square wire mesh Type G1 G2 Port option SF2 250 1 1/2 BSP 1 1/2 NPT H R S Q Options Without By-pass, without magnet With By-pass and magnet With By-pass, without magnet Without By-pass and magnet G3 SAE 4 G4 G5 G6 G7 G8 G9 F1 F2 1 1/4 BSP 1 1/4 NPT SAE 20 1 BSP 1 NPT SAE 16 1 1/2 SAE 3000 PSI/M 1 1/2 SAE 3000 PSI/UNC Seals (only for filter elements) N Buna N V Viton SF 250 M25 N This example shows how order a filter element with features based on the customer request Replacement element MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement elements and spares are used Data held in this publication is given only for indicative purposes. MP Filtri reserves to introduce modifications to described items for technical or commercial reasons. Copyright reserved. 7

Head Quarter : MP FILTRI S.p.A. Italy Via Matteotti, 2 20060 Pessano con Bornago (Milano) Italy Tel. ++39.02/95703.1 Fax ++39.02/95741497-95740188 email: sales@mpfiltri.com http://www.mpfiltri.com GREAT BRITAIN MP FILTRI U.K. Ltd. Bourton Industrial Park Bourton on the Water Gloucestershire GL54 2HQ UK Phone: 01451-822522 Fax: 01451-822282 email: sales@mpfiltri.co.uk http://www.mpfiltri.co.uk GERMANY MP FILTRI D GmbH Am Wasserturm 5 D-66265 Heusweiler/Holz Phone: 06806/85022-0 Fax: 06806/85022-18 email: mpfiltrink@aol.com FRANCE MP FILTRI FRANCE B.P. 325 01603 Trevoux Cedex Tel: 04.74.08.84.78 Telefax: 04.74.08.80.45 email: mpfiltrifrance@wanadoo.fr USA MP FILTRI USA Inc. 2055 Quaker Pointe Drive Quakertown, PA 18951 Phone: 215-529-1300 Fax: 215-529-1902 email: mpusasales@aol.com http://www.mpfiltriusa.com CANADA MP FILTRI CANADA Inc. 210 Jacob Keffer Parkway Concord, Ontario Canada L4K 4W3 Phone: 905-303-1369 Fax: 905-303-7256 email: mail@mpfiltricanada.com http://www.mpfiltricanada.com