HITACHI UPS Supports your Data Centre with Advanced Technologies Enhance capacity or achieve parallel architecture on the fly. Add as you need without taking a shutdown - multiple UPS units can be added to enhance the UPS rating or achieve a parallel configuration even while the base units are running. No shutdown - will not only ensure continuity of your data centre operations but will also ensure peace of mind with clean continuous power to all your sensitive equipment. Option to expand UPS units for future expansion marginal cost and smaller dimensions N+1 redundancy can be achieved without external system bypass switch Install additional units or maintain an existing unit without affecting the load Configure a highly robust and reliable system with dual input / output Units are available in ratings of 400 kva, 500 kva, 540 kva, 600 kva Up to 6 HITACHI UPS Systems can be configured as a parallel redundant system Select the functions & characteristics from eight standard system menus to meet your requirements Assured short lead time for delivery (typically three months) to match expansion plans www.hitachi-hirel.com 02
HITACHI UPS - The Perfect Match for Support to all your Critical Power Facilities Exceptional safeguard against power disruption Economy Nominal initial costs Low running expenses Scalable Expand on the fly No interruption of load Maintainability Colour LCD Panel On-line monitoring Innovative New Technologies Reliability Stable Power Supply Requirements Power saving feature Reduced footprint (suitable to be moved in an elevator) Lower maintenance costs Short lead-time delivery Reduce installation cost Enhance UPS Capacity as load increases User friendly UPS operations Remote monitoring Availability of clean continuous power Protection against full spectrum of power disturbances Reduced harmonics in the input power Reduced the effects on the back-up generator Reduced parts count Minimized common system control parts Back-up system availability HITACHI UPS Advanced Features High-efficiency (95%) Small footprint Light weight design Minimum replacement parts System menu setting Ready for on-floor installation Parallel ready on the fly Operational status, operational guidance, parameter monitoring, trend information etc... On-line trouble shooting and maintenance Sine-Wave output 200% overload capacity On-line double conversion Low input current harmonics High input power factor Suppression of the sub synchronous resonance Full Digital control True parallel redundant system Transformer less Inverter 415V input / output High performance battery bank Long life fans and capacitors Standard specifications engineered Utilization of floor wiring Configure parallel redundant system without external bypass switch Dual input / output system Touch panel color LCD Transmission of information to call centre via network IGBT inverter IGBT converter High performance SH micro computer Independent intelligent parallel control Hybrid automatic transfer / re-transfer switch N+1 redundancy Hitachi DATA Center UPS 03
Features of HITACHI UPS System Compact, Light-weight and High Efficiency Design A smaller foot-print means a larger space available for the customer's system. Lower power loss translates to lesser electricity costs and lower capacities required for the air-conditioning equipment. The 415 V UPS input / output allows for larger capacity feeding with low power losses. Advanced circuit technology and the high speed IGBT switching technology eliminate the need for an inverter transformer, directly saving valuable installation space as well as reducing substantial weight of the system. This enables the compact light weight system to be moved in an elevator for quick positioning on site. Comparison between conventional and new models (in terms of estimated electricity cost) Efficiency 92% Annual cost X $ Conventional Model Savings of 4.5% / Year Efficiency 95% Annual cost 0.95 x $ New Model Enhance Capacity or Achieve Parallel Architecture on the Fly The Hitachi UPS system provides the optimum return on investment with the facility to scale up Capacity or achieve parallel architecture without interruption of the running load. Each unit has an on-line double conversion topology with uninterruptible as well a maintenance bypass and battery. Standard Specifications Engineered Systems To ensure supply of electric power to a load operated on 24/7 for 365 days a year, it is essential that not only the UPS but also the peripheral devices should be maintainable and scalable during operation without taking a shutdown. Hitachi UPS offer four different options within the pre-engineered configurations enabling the customer to select the one that best meets their requirements. Deploying a standard specifications engineered system ensures shortened lead time for delivery and commissioning. www.hitachi-hirel.com 04
Long Life Components Exceptional safeguard against power disruption Frequent replacement of components is costly and recurring in terms of cost of the parts as well as charges payable to the personnel for the job. It will also call for a system shutdown leading to losses. Hitachi UPS systems are built with long life parts and by planning the replacements it is possible to reduce the running costs. The fan and capacitors are also long life parts that need replacement at very long intervals. The fuses need to be changed at the time of battery replacement. All these features contribute to substantial reduction in maintenance costs. UPS UPS serious fault UPS minor fault Battery low voltage Battery operation Pre-alarm of low battery shutdown Converter operation Load on inverter Load on bypass th 0 year On-floor Installation (Optional) The standard 50mm UPS base height can be increased to 200 mm to accommodate the wiring and provide free access on the floor around the UPS. This is very advantageous when setting up the data centre in an existing building and where it is difficult to prepare the pit for wiring. Floor Slab th 5 year Fuses High Base UPS th 10 year Fan / Capacitors Fuses On-line Maintenance Support (Optional) The UPS can be connected to a Local Area Network via the in-built SNMP card. A monitoring device on the customer's LAN makes it possible to constantly monitor the performance and parameters of the entire system. The remote monitoring feature offers automatic connection to the call centre and ensures speedy support in emergency situations. Standard Outgoing Signals (Dry Contacts, A-type ) Output panel Remote operation System load on inverter System load on bypass Synchronized with bypass Overcurrent Output ground fault Alarm of output panel th 15 year Expected life Free-Access Floor Hitachi DATA Center UPS 05
Technical Specification Main AC input DC Link Voltage AC Output Output Performance Ambient conditions Type 400 kva 500 kva 540 kva 600 kva Rated voltage 415 V Voltage range Within ±10% Rated frequency Frequency range Number of phases and wires Nominal volrage Voltage fluctuation range Number of battery cells Rated capacity Rated voltage Range of voltage regulation Rated frequency Number of phases and wires Rated load power factor Output power factor range Output voltage accuracy Transient voltage fluctuation Loss & rerun of AC input for 100% load step inverter bypass Parallel-on / Parallel-off Transient recovery time Voltage Linear load distortion Nonlinear load Frequency accuracy (free run) Frequency synchronization range Overload capacity Inverter Bypass circuit Voltage unbalance factor Overall efficiency Input power factor Ambient temperature Relative humidity Audible noise 50Hz / 60Hz Within ±5% 3-phase, 3-wire 492 V ~ 544 V 393 V ~ 607 V 246 to 272 400 kva 500 kva 540 kva 600 kva 800 kva 415 V Within ±5% Max. 65 db (A) 50Hz / 60Hz 3-phase, 3-wire / 3-phase, 4-wire 0.9 delay 0.7 delay ~ 1.0 Within ±1.0% Within ±2.0% Within ±5.0% Within ±5.0% Within 50ms 2.5% or less 5.0% or less Within ±0.1% Within ±1.0% 125% - 10 minutes 150% - 1 minute 200% peak 0.1 second* 1,000% - 1 cycle Within ±1.5% Up to 95% more than 0.95 0 C ~ 40 C 15% ~ 90% Max. 70 db (A) 800 kva Max. 75 db (A) 0.95 delay (option) with 100% imbalanced load at 100% load at 100% load non-condensing * 180% Peak 0.1 Second Single Line Diagram Maintenance Bypass Static Bypass Converter Inverter UPS www.hitachi-hirel.com 06
About Us Founded & established in 1983 as Hi-Rel Electronics Pvt. Ltd., we are now a Hitachi group company - Hitachi Hi-Rel Power Electronics Pvt. Ltd., recognized as a pioneer in power electronics. With 3 decades of experience, we have garnered a significant level of trust in our market segment and continue to offer world class power electronics products, value added services & customized solutions. Our product portfolio includes UPS (uninterruptible power supply) for industrial, commercial & enterprise applications, medium voltage & low voltage variable frequency drives, steel automation & engineered drives for customized applications, industrial automation & control products like PLC, SCADA & DCS, solar inverters, railway products and other customized products like UMPS, I-dip (dip ride through solutions). Leading manufacturer of UPS, drives & automation products and solar inverters State-of-the-art manufacturing facility at Gandhinagar & Sanand in Gujarat, India In-house R&D facility recognized by DSIR, Government of India ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007 certified company with export house status Approved by leading consultants and EPC vendors Pan India & global presence Serving entire gamut of industries Rich experience in mission critical applications Dedicated & decentralized 24x7 after-sales-service Offers products with greater energy efficiency & lower carbon footprint With expertise, experience and an efficient product line, we will always be your power electronics partner. When you choose to do business with us, you are partnering with a company who cares. Hitachi DATA Center UPS 07
Global & Pan India Presence USA Middle East Japan India South East Asia Africa Australia Jammu & Kashmir Jammu Amritsar Ludhiana Chandigarh Mandi Himachal Pradesh Punjab Jaipur Jodhpur Barmer Kanpur Gwalior Ajmer Udaipur Gandhinagar Ahmedabad Mehsana Sanand Mundra Jamnagar Rajkot Baroda Ankleshwar Surat Vapi Uttara khand Haryana Hisar Noida Lucknow Indore Bhopal Uttar Pradesh Rajasthan Maharashtra Nagpur Belgaum Siliguri Guwahati Gorakhpur Allahabad Muzzafarpur Gopalganj Arunachal Pradesh Ranchi Jorhat Sibsagar Meghalaya Bihar Sasan Korba Jharkhand Bokaro West Bengal Kolkata Jamshedpur Jajpur Angul Chattisgarh Bilaspur Cuttak Orisaa Bhubaneswar Raipur Bhilai Madhya Pradesh Gujarat Nashik Mumbai Pune Dehradun Moradabad Patna Agartala Hyderabad Vizag Rajahmundry Andhra Pradesh Bellary Kadapa Chennai Manufacturing Plant Mangalore Coimbatore Karaikal Palakkad Tamil Nadu Kerala Tiruneveli Corporate Office Branch Office Thiruvananthapuram Service Center Hitachi Hi-Rel Power Electronics Pvt. Ltd. Gandhinagar Works B - 14/1 & 171, GIDC Electronics Zone, Sector - 25, Gandhinagar - 382 044 Gujarat, India. Phone: +91-79-2328 7180/81, +91-79-6170 0500, Fax: +91-79-2328 7182 Email: contact@hitachi-hirel.com Web: www.hitachi-hirel.com HDCU / 01 / 16 / Ver.2 / Corp. Mktg. / India l Spotlight - 079 3002 2324 Karnataka Udipi Bangaluru