Eaton 93PM UPS Efficient. Scalable. Innovative.

Similar documents
Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton 93PM UPS Where aesthetics meet intelligence.

Data Center Trend: Distributed Power in the White Space

Galaxy VM. Three-phase power protection. schneider-electric.com

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Bringing value to colocation data centers

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

4.0 UPS dedicated to ICT for unmatched energy savings

Product brochure. Eaton 9390 UPS kva

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

PX100 MBP with Configurable Distribution

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Product brochure Eaton 93PS UPS 8-40 kw. More advanced. power. protection

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Overview brochure. Power management solutions for network closets, server rooms and data center environments

MAJORSINE Power Inverter

DATA CENTER SOLUTIONS

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

How To Make A Data Center More Efficient

RIELLO ELETTRONICA. Master HP

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

Liebert NXC from 10 to 200 kva

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

PowerGem Pro Uninterruptible Power Supply

Microsoft Technology Center: Philadelphia

ABB PSPS Erich Steinmann; Generator control-2013

SG Series UPS kva three phase 400 Vac

Wireless Networks and Power Quality

StruxureWare TM Center Expert. Data

Power Xpert 9395 UPS kva

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

Power distribution in data centres

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Increase the efficiency of power distribution in your high-density data center

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Smart-UPS 3 Phase And MGE Galaxy 3500

Data Center Racks. Vantage S2. Enclosure System. Switch N to Eaton.

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Data Center Solutions - The Containerized Evolution

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Phase Modular Finally the benefits of Modular ups are for all

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Scalable. Affordable. Flexible. Fast.

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Specification Requirements DBL 700MX and 1000MX Series UPS

TLE Series UPS kw for best-in-class multi-mode operating efficiency

Power protection for data centers

Evaluating the Opportunity for DC Power in the Data Center

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

StruxureWare TM Data Center Expert

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

DTU-52 Series. High-Power Digital TV Transmitter. Features

Power & Environmental Monitoring

Smart-UPS On-Line 230 V

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

POD S in Data Centres. The Frame Group Pty Ltd

Data centre experts. Advanced power protection for data centres

Transmission System Total Cost of Ownership

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Technical Data. back-up time in minutes 100% load % load

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Choosing Close-Coupled IT Cooling Solutions

Energy Efficient High-tech Buildings

APC APPLICATION NOTE #92

Managing Data Centre Heat Issues

Product catalog ABB UPS products and solutions Power protection for critical infrastructures

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

HVAC DRIVE H300 HVAC Drive for Building Automation

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

The Mission Critical Data Center Understand Complexity Improve Performance

ADC-APC Integrated Cisco Data Center Solutions

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Intelligent power measurement in data centres

Small Data / Telecommunications Room on Slab Floor

Data Center Facility Basics

The New Data Center Cooling Paradigm The Tiered Approach

Transcription:

Product rochure 20-100 kw aton UPS fficient. Scalable. Innovative.

features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible device that s as easy to deploy as it is to manage, it s the perfect three-phase white or grey space solution for today s data center. 1. Lowest TCO (Total cost of ownership) Redundant 50 kw 50 kw Competitive system with UPS redundancy Conserves valuable data center floor space with its compact footprint and internal redundancy design Reduces cost and unexpected future growth risks with it s vertical scalability, enabling you to scale as you grow battery cabinet 50 kw redundant UPS maintenance bypass aton UPS with redundancy distribution cabinet Reduces power and cooling OPX through industry-leading energy- 99% with SS Up to 97% in double-conversion mode The s vertical scalability, internal redundancy and compact footprint design UPS (%) 100 90 80 SS Double-conversion mode Competitive UPS The SS energy cost savings pay for the UPS in less than 3 years. Calculate your savings with SS at aton.com/ss. Typical Operating Range 70 10 20 30 40 50 60 70 80 90 100 UPS load (%) aton in double conversion and SS annual savings vs. leading competitor Load % Leading competitor ** SS SS annual savings($)* doubleconversion double-conversion annual savings ($)* 25% 84.0% 98.4% $6,868 95.8% $5,780 50% 90.6% 98.9% $7,303 96.8% $5,574 The doubleconversion energy savings pay for the UPS in less than 4 years. 75% 92.5% 99.1% $8,515 97.0% $5,931 100% 93.0% 99.1% $10,436 96.8% $6,656 * Savings calculated using $0.10 kw/hr. and 80% cooling ratio (currency in US dollars) ** Leading competitor does not offer SS mode 2 aton UPS 800.672.7244 www.hmcragg.com 2 TON aton UPS

2. asy deployment Maximizes deployment flexibility by providing flexible configurability The supports front-to-top ventilation, ideal for against the wall configuration. Front-to-top ventilation feature also makes the a perfect fit for in-row configurations that support slim chimneys. The also supports front-to-back ventilation making it great for hot/ cold aisle configuration. 3 aton UPS 800.672.7244 www.hmcragg.com TON aton UPS 3

LD light bars Green light bars showing healthy UPS. 3. asy management Provides easier access to detailed status information through its large, user-friendly LCD touchscreen interface With the s graphical LCD interface you can track stats on energy savings, battery time, outage tracking, load profiling and much more. The green/yellow/red LD lightbars make system status visible from a distance in data centers. Red light bars showing alerts on system. Yellow light bars indicate battery and bypass status. Intelligent Power Manager seamlessly integrates into the major virtualization platforms, including VMware, Citrix, Red Hat and Microsoft Systems Center. Communication card Connectivity options: Power Xpert Gateway Mini-slot communication card Industrial relay card Integrates with the leading virtual platforms through its full suite of power management and connectivity software Designed for the most advanced IT environments, the supports optional communication cards that allow remote access via the HTTP(S), SNMP, MODUS TCP/IP, Modbus RTU and Cnet IP protocols. In addition, aton s Power Xpert software and Intelligent Power Software Suite give you all the tools you need to manage power devices in your physical or virtual environment. Learn more at aton.com/intelligentpower. Increases uptime through its 24x7 remote monitoring and reporting capabilities aton s enotify Remote Monitoring Service provides 24x7 real-time monitoring of the and alerts service technicians to take necessary measures when a problem is detected. Learn more at aton.com/enotify. 4 aton UPS 800.672.7244 www.hmcragg.com TON aton UPS 4

aton s comprehensive portfolio Integrated data center products and services C D F G H J I Overhead Cable Management Solutions Thermal Management Solutions C usway D epdus isle based Power Management Solutions (UPSs) 5 aton UPS 800.672.7244 www.hmcragg.com eaton.com/datacenters F G Rack Monitoring Solutions Rack-based Power Management Solutions (UPSs) H IT enclosures I Customized Service plans J Management Software TON aton UPS 5

The functional core of the UPS C Top cable entry comes with sidecar/maintenance bypass options (sidecar option is required for top cable entry) D Front View Communications and connectivity C uilt-in device and host US Five alarm inputs and dedicated PO larm relay output Four communication slots Color touchscreen LCD interface 74 H F D Serviceable redundant fan assembly Replaceable power modules (50 kw) with independent control and power G H F Soft start controls G H I Modular static switch assembly (independent power and control) Redundant bypass control Input/output connections 42 D I 99% SS 97% doubleconversion 22 W Open front view of the unit aton UPS technical specifications * Power modules for 100 kw frame Power offering (kw) 50, 50+1, 100, 100+1** (Derates available in 10 kw increments) General charaterstics fficiency in nergy Saver System (SS) 99% fficiency in double-conversion mode Up to 97% Parallel capability 4 distributed Input characterstics Voltage 480V Voltage range +10% / -15% Frequency range 40-72 Hz Power Factor >.99 Input current distortion < 3% @ 100% load capacity attery attery voltage Charging method 432V M or float technology Output Voltage Regulation Voltage THD Load power factor range 480V (208V with IC-D) ±1% steady state <1% (100% linear load); <5% (non-linear load).8 leading to.8 lagging without de-rating Certification Safety UL1778, cul MC FCC Part 15 subpart class Surge IC 61000-4-5 Optional accessories xternal slim maintenance bypass Integrated distribution cabinet (with output transformer options) Integrated parallel tie cabinets Integrated battery cabinet (small and large) *Due to continued improvements, specifications are subject to change. **+1 provides 50 kw of internal redundancy at full load. aton lectrical Sector 1000 aton oulevard Cleveland, OH 44122 US Contact Your HM Cragg aton.com Territory Sales Manager aton, M, Intelligent Power and 2013 aton Power Xpert are registered trademarks for more information aton s UPS ll Rights Reserved of aton Corporation. at Printed US R153026N ll other trademarks are property 800.672.7775, or email info@hmcragg.com September 2013 of their respective owners. www.hmcragg.com Learn more at aton.com/