Fire Protection Coffee Break Training August 2014



Similar documents
MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

Fire Alarm Submittal Requirements and Acceptance Testing

Building Permit Application

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

BUILDING PERMITS. Santa Rosa County Building Inspection

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Maintaining Fire Protection Systems

How To Get A Fire Alarm Permit In Vail

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

SECTION FIRE ALARM AND DETECTION SYSTEM

Winnipeg Fire Department Fire Prevention Branch

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

EXHIBIT A SCOPE OF WORK

2014 Limited Plan Submittal Checklist

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

C. Conform to requirements of Americans with Disabilities Act (ADA).

Bold items are particular to the City of Euless

Development Services Guidelines

Appendix B Forms for Inspection, Testing, and Maintenance

University Design Standard. Fire Alarm Systems

Important Ontario Fire Code Information for Building Owners in the City of Windsor

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Fire Prevention Coffee Break Training. November 2015

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

ESTABLISHMENT OF A NEW BUSINESS

CHAPTER 9 FIRE PROTECTION SYSTEMS

PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM

Division 21. Fire Suppression

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

ENVIRONMENTAL HEALTH AND SAFETY. Fire Protection System Impairment Procedure

Automatic Fire Sprinkler Submittal Requirements

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Fire Alarm Systems Requirements by Occupancy Type

Columbia University Medical Center. Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems

IR F-1 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS

BEDFORD FIRE DEPARTMENT FIRE PREVENTION BUREAU FIRE CODE HANDBOOK

FOR CERTIFICATION AS PRESCRIBED BY THE STATE FIRE PREVENTION COMMISSION ON NOVEMBER 11, 2009 IN ACCORDANCE WITH THE STATE FIRE PREVENTION REGULATIONS

HERNANDO COUNTY FIRE ALARM GUIDELINES

TOWN OF DAVIE BUSINESS TAX RECEIPT 6591 ORANGE DRIVE DAVIE, FLORIDA PHONE: FAX:

South Carolina DSS. "Records and Reports" 7-12

Development Services Guidelines

City of Bettendorf Fire Alarm System Requirements

FIRE ALARM SYSTEM PLAN SUBMITTAL CHECKLIST

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Name Of Occupancy Date. Yes No Describe

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Fire Department Fire Prevention Inspection Services. ASSEMBLY OCCUPANCY Fire Inspection Program

Minnesota State Department of Public Safety

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

National Archives and Records Administration (NARA) Facility Standards for Federal Records Storage Facilities

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Aurora Mall. Aurora (Denver), Colorado

Overview of Hotel Fire Safety Requirements

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

FIRE ALARM APPLICATION

Project Close Out Summary

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Design & Construction Standards, Revised January

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

City of Columbus Department of Building and Zoning Services

CERTIFICATE OF COMPLIANCE

Automatic Fire Sprinkler System Checklist

PROPOSED FIRE INSPECTION SYSTEM THIRD PARTY REPORTING

Smoke Detector/Carbon Monoxide Detector Inspections

Program No Section Heading

Smoke & Carbon Monoxide

Guide to Massachusetts Smoke & Carbon Monoxide Requirements

city of edmonds development information

C I T Y O F S E L M A F I R E D E P A R T M E N T

PART II: New Construction Inspections and Acceptance Testing Procedures

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Transformer Deluge Systems

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

Transcription:

Fire Protection Coffee Break Training August 2014

Agenda Opening from Chief TeKippe Introduction of Communication Strategy Fire Marshal Lund New Fee Schedule Fire Marshal Lund Submittals, Resubmittals, and Administrative Holds FPE Phelan Questions and Answers Open Forum

Communication Strategy Goal: Improve Communications Between contractors/design professionals and the fire department Fire Protection Newsletter 1 page quick-hitter Important Information Leads up to next presentation Fire Protection Coffee Break Training What we are doing today

Fee Schedule Changes Changes to all Fire Prevention Permit Fees Annual Permits, Temporary Permits, Construction Permits (fire protection systems) Based on Fee Consultant Study conducted by the City of Des Moines Adopted by City Council

Sprinkler System Permit Fees Fee Amount Description $ 150.00 Fire Sprinkler System (modifying 20 sprinklers or less) $ 300.00 Fire Sprinkler System 0-10,000 square feet $ 450.00 Fire Sprinkler System 10,001-25,000 square feet $ 600.00 Fire Sprinkler System 25,001-50,000 square feet $ 900.00 Fire Sprinkler System 50,001-100,000 square feet $ 1,350.00 Fire Sprinkler System 100,001-200,000 square feet $ 1,750.00 Fire Sprinkler System 200,001-300,000 square feet $ 2,150.00 Fire Sprinkler System 300,001-400,000 square feet $ 2,650.00 Fire Sprinkler System 400,001-500,000 square feet $ 3,350.00 Fire Sprinkler System >500,000 square feet $ 200.00 Addition of a Backflow Prevention Device to an existing sprinkler system $ 300.00 Standpipe system (not part of a sprinkler system) $ 200.00 Fire Pump & related equipment (per pump) 1/2 Fee Resubmittal of any fire protection system plans 2x Fee Failure to obtain a permit prior to installation (may also be subject to stop work order)

Fire Alarm System Permit Fees Fee Amount Description $ 300.00 Fire Alarm System 0-10,000 square feet $ 450.00 Fire Alarm System 10,001-25,000 square feet $ 600.00 Fire Alarm System 25,001-50,000 square feet $ 900.00 Fire Alarm System 50,001-100,000 square feet $ 1,350.00 Fire Alarm System 100,001-200,000 square feet $ 1,750.00 Fire Alarm System 200,001-300,000 square feet $ 2,150.00 Fire Alarm System 300,001-400,000 square feet $ 2,650.00 Fire Alarm System 400,001-500,000 square feet $ 3,350.00 Fire Alarm System >500,000 square feet $ 200.00 Fire Alarm Control Unit (replacement or addition) $ 200.00 Other protection systems tied into the fire alarm system (e.g. delayed egress) 1/2 Fee Resubmittal of any fire protection system plans 2x Fee Failure to obtain a permit prior to installation (may also be subject to stop work order)

Fire Protection System Permit Fees Fee Amount Description $ 150.00 Kitchen Hood Suppression System (per hood) $ 400.00 Clean Agent or Other Suppression System 0-2,500 square feet $ 550.00 Clean Agent or Other Suppression System 2,501-5,000 square feet $ 800.00 Clean Agent or Other Suppression System >5,000 square feet 1/2 Fee Resubmittal of any fire protection system plans 2x Fee Failure to obtain a permit prior to installation (may also be subject to stop work order)

What Requires a Resubmittal? aka what mistakes are going to cost me more money?

Overview of the Line in the Sand Resubmittal If it requires significant time to discover the omission or error and to review the corrected or additional materials that will require a re-submittal and the resubmittal fee will be charge. Administrative Hold If it requires minimal time to discover the omission or error or review the corrected or additional materials.

Overview of the Line in the Sand No Resubmittal Fee Forgot to include a required part of the submittal. Resubmittal Fee A submitted part of the submittal contained errors.

Specific Examples Sprinklers Not required Omitted flow test data including date. Omitted calc for quick response area reduction Used incorrect or omitted loss for backflow preventer, but margin of safety is sufficient to compensate. Omitted location of expansion loop for pvc pipe. Additional Spk required outside the hydraulically most remote area. Required Used wrong Hazard/Density in Calc s Used incorrect or omitted loss for backflow preventer, but margin of safety is not sufficient to compensate. Additional spk required in hydraulically most remote area.

Specific Examples Fire Alarm No Fee Omitted calculations Omitted technical specifications Omitted ceiling heights Calc d backup battery for voice system at 5 min not 15 min no additional battery required. Did not designate use of all spaces to verify notification requirements. No changes required. Fee Used incorrect wire resistance in calc s Calc d backup battery for voice system at 5 min not 15 min additional battery required. Did not denote acoustically distinguishable spaces and intelligibility test locations. Did not designate use of all spaces to verify notification requirements. Changes required.