FREDERICK SHERRELL LTD



Similar documents
FACTUAL GROUND INVESTIGATION

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

JOHNSON STREET BRIDGE REPLACEMENT PROJECT

FINAL REPORT ON SOIL INVESTIGATION

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Merivale

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.

KWANG SING ENGINEERING PTE LTD

SYDNEY SANDSTONE AND SHALE PARAMETERS FOR TUNNEL DESIGN

23 Royal Avenue London. Geotechnical Assessment Report. Report No. LW September 2014

CIVL451. Soil Exploration and Characterization

Chittagong Hill Tract Development Facilities (CHTDF) United Nations Development Programme

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.

Geotechnical Investigation using Standard Penetration Test (SPT) in Rangamati, Bandarban and Khagrachari Towns

EARTHWORKS COMPLETION REPORT ELLEN STIRLING PARADE, ELLENBROOK. Ellenbrook, W.A. Georgiou Group Pty Ltd

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples

PAPAMOA EAST URBAN DEVELOPMENT PART 1 AREA LIQUEFACTION HAZARD REVIEW Technical Report

Report on Engineering Geological Investigation: Test pit logs in KwaMhlanga for RDP houses development.

Geotechnical Investigation Test Report

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils

HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT

How To Design A Foundation

APPENDIX F GEOTECHNICAL REPORT

Report. Geotechnical Investigation Proposed Easy Access Upgrade Marrickville Railway Station Station Street, Marrickville, NSW

1.0 INTRODUCTION SCOPE OF WORK EXECUTION OF FIELD WORK LABORATORY TESTS FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Council of the City of Gold Coast

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

TECHNICAL NOTE: SI 01 SPECIFIC REQUIREMENTS FOR THE ACCREDITATION OF INSPECTION BODIES FOR SITE INVESTIGATION

GUIDELINES FOR GEOTECHNICAL INVESTIGATION OF BRIDGE STRUCTURES. Materials Engineering Report No M (Supersedes Report No.

NUMERICAL ANALYSIS OF SEEPAGE THROUGH EMBANKMENT DAMS (CASE STUDY: KOCHARY DAM, GOLPAYEGAN)

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey

Anirudhan I.V. Geotechnical Solutions, Chennai

S OIL C ONSULTANTS LTD

FIELD DESCRIPTION OF SOIL AND ROCK GUIDELINE FOR THE FIELD CLASSIFICATION AND DESCRIPTION OF SOIL AND ROCK FOR ENGINEERING PURPOSES

Trench Rescue by Buddy Martinette

Assessment. Ian Uglow Technical Director, SLR Consulting 7 th October 2010

SERVICES 2015 ISO 18001

GEOTECHNICAL INVESTIGATION. Adelaide Street Pollution Control Plant Outlet Structure Replacement London, Ontario

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

Report on Ground Investigation Report No /RVX-6. The Yorkshire and Humber (CCS Cross Country Pipeline) Development Consent Order

Ground investigation and Eurocode 7: A Scottish perspective

Soil behaviour type from the CPT: an update

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

Moving Small Mountains Vesuvius Dam Rehab

QUESTION TO AUDIENCE

G-126 (Continued) MTA Westside Subway Extension Los Angeles, California. Figure: A-2.22c

ENCE 4610 Foundation Analysis and Design

Washington ,

The Manitoba Water Services Board SECTION Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

NOTES on the CONE PENETROMETER TEST

What is Soil Survey?

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

patersongroup Geotechnical Investigation Proposed Residential Development 590 Hazeldean Road - Ottawa Prepared For Ontario Inc.

EXPLAINING GROUNDWATER AND WATER WELLS

Chapter 9: Water, Hydrology and Drainage Land West of Uttoxeter

Treatment Practice for Controlling Water Damage in the Annular Space of Shaft Freezing Hole

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

King Saud University College of Engineering Civil Engineering Department DEFORMATION OF PARTIALLY SATURATED SAND. Sultan Musaed Al-Ghamdi

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

A CASE STUDY: DESIGN AND CONSTRUCTION OF FOUNDATION AND BRACED EXCAVATION AT A RECLAIMED SITE AT WATERFRONT

SNC-Lavalin Inc. Montcalm Wastewater Pumping Station Upgrades - Geotechnical Report. October 2011

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

WEATHERING, EROSION, AND DEPOSITION PRACTICE TEST. Which graph best shows the relative stream velocities across the stream from A to B?

hs2 Ground A non-technical guide

ANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY

Improvement in physical properties for ground treated with rapid impact compaction

Buildings Department Practice Note for Registered Contractors 38. Registration of General Building Contractors and Specialist Contractors

Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT

PILE FOUNDATIONS FM 5-134

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

Proceedings 2005 Rapid Excavation & Tunneling Conference, Seattle

COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2

Bedwyn Brail, Wiltshire: Geophysical and Earthworks Survey

WEST LONDON PIPELINE AND STORAGE LIMITED AND UNITED KINGDOM OIL PIPELINES LIMITED

A historic sea wall revealed; archaeological trial-trenching at the Proctor & Gamble London site, West Thurrock, Essex February 2013

How To Map A Lake In The North Of The Holland (Fiji)

WDC Whakatane Central Business District Geotechnical Investigation

Vulnerability Assessment

Use of a Reinforced Jet Grout Excavation Support System for a Major Sewer Line Repair

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

WILLOCHRA BASIN GROUNDWATER STATUS REPORT

Geotechnical Investigation Report London Street Generating Station Peterborough, Ontario. February 2012

UNDERPINNING OF NEW STUDENT HOUSING BUILDING USING MICROPILES, NORTH CAROLINA USA

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

Dip is the vertical angle perpendicular to strike between the imaginary horizontal plane and the inclined planar geological feature.

(

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

Pile test at the Shard London Bridge

Permafrost in Marine Deposits at Ilulissat Airport in Greenland, Revisited

Groundwater Flooding: a UK Perspective

Transcription:

FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS 66 WEST STREET TAVISTOCK DEVON PL19 8AJ Your Ref: Our Ref: 2962.NS.JR Telephone: 01822 612915 Facsimile: 01822 617394 info@fredericksherrell.co.uk www.fredericksherrell.co.uk Engineering Design Group, Devon County Council Matford Lane Offices, County Hall, EXETER. EX2 4QW 3 rd August 2007 For the attention of Mr. Rob Richards Dear Mr. Richards, Site Investigation for Sewer Pipe Crossing of the River Exe at Ashley, Tiverton In accordance with your instructions on 11 th 13 th June a borehole investigation was carried out of the site of a proposed replacement sewerage pipe beneath the River Exe at Ashley, Tiverton (see Figure 1). We understand that it is intended to install the pipe using directional drilling methods. The purpose of the investigation was to provide information regarding the nature and depth of the soils and bedrock to assist with the planning and design of the proposed directional drilling contract. Two boreholes were sunk on opposite banks of the River Exe by Geotechnical Engineering Ltd using a tracked Comacchio Pioneer drilling rig to obtain core samples of the soil and rock. The borehole locations are indicated in Figure 2 and illustrated in Photographs 1 and 3. The boreholes were logged by an Engineering Geologist from Frederick Sherrell Ltd and representative samples were taken for laboratory testing. Insitu Standard Penetration Tests were carried out during the course of the works and a standpipe was installed in Borehole B1 to allow falling head permeability tests to be undertaken. The borehole logs are appended to this report, together with the results of insitu and laboratory testing. The results of the investigation are summarised in the following paragraphs. 1. THE SITE 1 1. The site is located on the flood plain of the River Exe 2km south of Tiverton, as shown in Figure 1. On the eastern bank of the river is the South West Water Sewerage Treatment Works and on the western bank of the river is farm land and the A396. The flood plain is approximately 300m wide at this location. road and sewerage works lie between the steeply sloping valley sides of the Exe Directors: R.D.J. Gould, B.Sc., C.GeoI., F.G.S. J. Rickeard, B.Sc., A.R.S.M., C.GeoI., F.G.S. Registered Office : 66 West Street, Tavistock, Devon PL19 8AJ. Registered in England No. 2797097 V.A.T. Registration No. 591 3193 33

Valley. The Ordnance Survey map of the area indicates that ground level on the flood plain is approximately 53m above Ordnance Datum at the borehole locations. 1 2. Reference to the published British Geological Survey map of the area, Sheet 310, Tiverton, shows that the site is underlain by Sandstones and Shaley Mudstones of Upper Carboniferous geological age. The map indicates that the bedrock is mantled by alluvium. 2. RESULTS OF THE INVESTIGATION 2 1. Sequence of Soils and Bedrock 2 1.1. Detailed logs of the boreholes are appended to this report. The ground conditions revealed by the boreholes are summarised in the table below. Formation Recorded Thickness (m) West Bank (B2) East Bank (B1) Topsoil 0.1 0.2 Alluvial SILT, CLAY and fine SAND 1.3 2.2 Alluvial GRAVEL 2.2 1.6 MUDSTONE and SANDSTONE bedrock. Depth to Rockhead : 3.6 4.0 Depth to Groundwater (13.6.2007) : 3.1 2.47 The soils and bedrock are briefly described in the following paragraphs. 2 2. Overburden Soils 2 2.1. The boreholes encountered 0.1 0.2m thickness of agricultural topsoil. 2 2.2. The topsoil is underlain by alluvial soils comprising an upper layer of relatively finegrained soils and a basal layer of gravels. On the west bank the upper layer comprised soft to firm, locally very soft organic gravelly clay and sandy silt, whilst on the east bank loose to medium dense silty sand was recorded. The basal layer comprises medium dense to dense, becoming very dense, clayey sandy gravels with occasional rounded cobbles of sandstone. 2 2.3. An N value of 8 was recorded from a Standard Penetration Test in the alluvial clay in - 2 -

Borehole B1. Higher N values were recorded in the alluvial gravels, ranging from N = 15 in Borehole B2 at 1.2m depth, to N = 117 150 at depths greater than 2.5m. 2 3. Bedrock 2 3.1. Pinkish grey mudstone bedrock was encountered in the boreholes beneath the alluvial gravels at approximately 3.6m and 4.0m depth below ground level on the west and east side respectfully. At rockhead the bedrock is highly fractured with much clay infill recorded in Borehole B1. Below about 5.7m depth the bedrock is typically slightly weathered and very close to closely fractured with Rock Quality Designation values generally 0% and Solid Core Ratios in the range 0 44%. Bedding planes dip at approximately 15-20 to the horizontal (locally 45 ) and are rough and undulating. The rock cores are also broken by at least two sets of smooth, planar joints, which dip at 65-90 oblique to the bedding. 2 3.2. In BH2 (west bank) fine grained sandstone was encountered below 7.0m depth. Rock Quality Designation values of 0% and Solid Core Ratios in the range 25 90% were recorded in the sandstone. The sandstone is very thinly to thinly bedded with bedding planes dipping at 10-15 to the horizontal. 2 3.3. The intact mudstone and sandstone bedrock was described as moderately weak to moderately strong, locally strong in the borehole descriptions. Insitu SPT tests recorded N values typically in the range 428-600 (extrapolated from penetrations <300mm) in the slightly to moderately weathered bedrock. A lower N value of 60 was recorded in the highly fractured zone close to rockhead (Borehole B1). Low Is 50 values in the range 0.04-0.17MPa were recorded from Point Load Index Tests, indicating probable failure along incipient fractures within the bedrock samples. 2 4. Groundwater 2 4.1. Groundwater was recorded at 2.4m and 3.1m depth below ground level on the east and west sides respectively. A standpipe was installed in BH1 (east side) with the response zone in the slightly weathered mudstone at 6.50-10.00m below ground level. The results of falling head permeability tests in the standpipe are appended and indicate a moderate permeability of 1.5-1.8 x10-6 m/s. - 3 -

3. GEOTECHNICAL CONSIDERATIONS 3 1. Geotechnical Considerations Relating to Construction 3 1.1. We understand that the new sewer will be installed within the bedrock beneath the bed of the River Exe using directional drilling techniques. The rockhead profile is likely to dip beneath the river channel and the vertical alignment of the proposed sewer should take account of the need to maintain adequate cover of rock above the pipe crown. The information within the borehole logs and test results should be used by the contractor to determine the most appropriate drilling technique. 3 1.2. The results of permeability tests indicate a moderate permeability within the bedrock. Higher permeability values might be anticipated within the highly fractured rock near the rockhead and in the overlying alluvial gravel. Water flow within the bedrock is likely to be concentrated along natural fractures within the rockmass rather than through the material itself and there is a risk that drilling fluids could possibly migrate through fracture zones within the rock into the overlying alluvial gravels and thus into the river itself. Drilling operations and pipe installation will need to take account of the risk of migration of drilling fluids or grouts through the bedrock and the requirements of the Environment Agency with regard to protection of the River Exe. 3 2. Chemical Considerations 3 2.1. Six samples of soil and rock were tested at the laboratories of Geotechnical Engineering Ltd for the presence of water soluble sulphate and ph value. The test results are summarised in Table 1 and indicate low concentrations of water soluble sulphate (maximum 0.2 g/l SO 4 in 2:1 water : soil extract) and slightly acidic to slightly alkaline ph values in the range 5.7 8.3. 3 2.2. One sample of ground water was tested for Sulphate and ph at ALcontrol Laboratories, Chester. The test results are shown in Table 1 and demonstrate low concentrations of sulphate (0.061 g/l) and an alkaline ph value of 11.8. 3 2.3. The results indicate that the site falls within Design Sulphate Class DS 1 of Table C1 of BRE Special Digest 1, Concrete in Aggressive Ground, 2005. Table C1 indicates an ACEC class of AC 1 for mobile groundwater. - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 -

We trust that these notes are sufficient for your requirements. Please do not hesitate to contact us if you have any queries. Yours sincerely, for Frederick Sherrell Limited Nigel Singleton - 5 -

TABLES

Sample Depth Material Water Soluble Sulphate as SO3 2:1 Extract Water Soluble Sulphate as SO4 2:1 Extract Total Sulphate Total Sulphur ph Value m g/l g/l % % BH01 1.3 Alluvial Clay <0.1 <0.1 7.1 BH01 2.5 Alluvial Gravel 0.17 0.2 6.2 BH01 4.0 Mudstone <0.02 <0.024 <0.01 <0.03 8.1 BH01 3.0 Groundwater 0.061 11.83 BH02 1.3 Alluvial Sand <0.1 <0.1 5.7 BH02 2.7 Alluvial Gravel <0.1 <0.1 5.7 BH02 5.2 Mudstone <0.02 <0.024 <0.01 <0.03 8.3 RIVER EXE CROSSING, TIVERTON SUMMARY OF GEOCHEMICAL TEST RESULTS TABLE 1 Jul. 2007, Job No. 2962 FREDERICK SHERRELL LTD

FIGURES 1 2

PHOTOGRAPHS 1 4

BOREHOLE LOGS

SOIL DESCRIPTIONS Soil descriptions are generally in accordance with BS5930 (1999), with modifications based on Norbury et al (A Critical Review of Section 8, BS5930 Soil and rock description. Proc. 2 nd Regional Meeting, Engineering Group of the Geological Society (1984)). Descriptive System Principal constituent shown in capitals Secondary constituents (% of total soil) Slightly sandy GRAVEL 0 5 sandy GRAVEL > 5 20 very sandy GRAVEL >20 Soils with more than two constituents are described using the same convention, e.g. : slightly silty, very sandy GRAVEL (0 5% silt) (>20% sand) Silt and Clay Soils Mixed silt and clay soils are described as slightly silty/silty/very silty CLAY or slightly clayey/clayey/very clayey SILT, depending on the soil behaviour and index properties. Composite Soils Composite soils such as severely gap-graded deposits, interlayered soils or those with lenticular inclusions and soils containing cobbles and boulders are described using the terms set out in Clause 41.4.4.2, as follows : Principal soil type with a little (occasional) 0 5% Principal soil type with some > 5 20% Principal soil type with much >20 50% Principal soil type and approx. 50% e.g. silty SAND with occasional/some/much gravel Page 1 of 1 FSLS009 Amended December 2003 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

ROCK DESCRIPTIONS Terminology The description of rocks generally follows the recommendations given in Section 6 of BS5930 (1999), with the exception of the description of weathered state and fracture state. Classification of Weathering The rock weathering scheme used in this report is as defined in Quarterly Journal of Engineering Geology (1972) : TERM Residual Soil DEFINITION Rock is discoloured and completely changed to a soil in which original rock fabric is completely destroyed. Completely weathered Highly weathered Moderately weathered Slightly weathered Fresh Rock is discoloured and changed to a soil but original fabric is mainly preserved. There may be occasional small corestones. The properties of the soil depend in part on the nature of the parent rock. Rock is discoloured; discontinuities may be open and have discoloured surfaces, and the original fabric of the rock near to the discontinuities may be altered. Alteration penetrates deeply inwards, but corestones are still present. (The ratio of original rock to weathered rock is estimated where possible.) Rock is discoloured; discontinuities may be open and will have discoloured surfaces with alteration starting to penetrate inwards; intact rock is noticeably weaker, as determined in the field, than the fresh rock. (The ratio of original rock is estimated where possible.) Rock may be slightly discoloured, particularly adjacent to discontinuities, which may be open and will have slightly discoloured surfaces; the intact rock is not noticeably weaker than the fresh rock. Parent rock showing no discolouration, loss of strength or any other weathering effects. References : BS 5930 : 1999 : Code of practice for site investigations (Formerly CP 2001) (British Standards Institution) QJEG : 1972 : The preparation of maps and plans in terms of engineering geology (Quarterly Journal of Engineering Geology Vol. 5, No. 4) Page 1 of 1 FSLS010 Amended December 2003 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

DEFINITION OF FRACTURE STATE INDICES ROCK CORE SAMPLES The measurement of fracture state has been carried out in accordance with the principles outlined in BS 5930, as follows :- Total Core Recovery (TCR) The length of the total amount of core sample recovered, expressed as a percentage of the length of the core run. (BS 5930 : 1999 Site Investigations, p 136) Solid Core Recovery (SCR) The length of core recovered as solid cylinders (i.e. core with a full circumference) expressed as a percentage of the length of the core run. Length is measured along the core axis. (Modified from BS 5930 : 1999 Site Investigations, p 136) Rock Quality Designation (RQD) The length of core recovered as solid cylinders (i.e. core with a full circumference) each more than 100mm long, expressed as a percentage of the length of the core run. Length is measured along the core axis. (Modified from BS 5930 : 1999 Site Investigations, p 136) Fracture Index (FI) The total number of natural fractures per unit length of core recorded for each core run or for lithological units where appropriate and expressed as fractures per metre. NB : HF = Highly Fractured (>40 fractures/metre) NI = Non-Intact Core NR = No Recovery Length of core run = L (%) Total Core Recovery = T/L (%) L T S R Solid Core Recovery = S/L (%) Rock Quality Designation = R/L (%) (R >10cm) Page 1 of 1 FSLS011 Amended February 2004 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

Site/Project Name RIVER EXE CROSSING, TIVERTON Grid Ref. Ground Level m BOREHOLE BH1 Method Machine Sheet Window Sampling : Rotary Coring (water flush) : 0.00-3.50m 3.50-9.80m Comacchio Pioneer 305 1 of 2 Contractor GEOTECHNICAL ENGINEERING LTD Diameter Core : 89mm Date 11.6.07 12.6.07 Symbolic Log Description Depth (m) Level (m ) Sample, Test or Core Recovery % Depth (m) of Sample, Test or Core Run R.Q.D. % (S.C.R. %) Fracture Index (no. per metre) S.P.T. N Value Water Casing Date Brown gravelly sandy clayey TOPSOIL with roots Soft-firm, brown, slightly sandy, gravelly CLAY mottled grey and orange with organic material and occasional rounded cobbles of sandstone 0.20 11/6 N D 1.20 1.30 8 Very soft-soft, greyey brown, gravelly sandy SILT with fine rootlets. Dense, orangey brown, medium-coarse GRAVEL of sub angular-sub rounded sandstone with much orangey brown clay in upper levels and occasional rounded cobbles of sandstone in the lower levels. 2.20 2.40 N D 2.20 2.50 47 D 3.25 Highly to moderately weathered pinkish grey silty MUDSTONE. Moderately weak to moderately strong. Very close to extremely closely fractured with much clay infill in the upper levels. 4.00 N 43 N 66 3.50 4.20 0 (0) 0 (0) 49 for 125mm pen. 50 for 250mm pen. 4.80 5.70m : Becoming slightly weathered and very close to closely fractured. Bedding dips 20 o (locally 45 o ), very thinly - thinly bedded, rough-undulating. Joints dip vertically and 70 o oblique to bedding, smooth-planar 66 N 73 5.70 0 (0) 0 (0) HF 17 50 for 35mm pen. 11/6 12/6 N 100 6.80 0 (44) 19 50 for 25mm pen. 100 N 100 7.70 8.20 0 (26) 25 (35) 20 15 50 for 25mm pen. Comments & Notes Inspection pit dug to 1.20m. Standpipe installed in gravel cell, 6.30-9.80m. Water standing at 2.47m bgl on 13.6.2007. Client DEVON COUNTY COUNCIL FSLS001a - Amended January 2005 U Undisturbed Sample (U100) B Bulk Disturbed Sample D Disturbed Sample W Water Sample N Standard Penetration Test K Falling Head Permeability Test Logged by Checked by NS JR RQD SCR V Rock Quality Designation Solid Core Recovery Groundwater First Encountered Standing Water Level Depth of Casing Insitu Vane Shear Test Scale 1:50 Job Ref. 2962 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

Site/Project Name RIVER EXE CROSSING, TIVERTON Grid Ref. Ground Level m BOREHOLE BH1 Method Machine Sheet Window Sampling Rotary Coring (water flush) : : 0.00-3.50m 3.50-9.80m Comacchio Pioneer 305 2 of 2 Contractor GEOTECHNICAL ENGINEERING LTD Diameter Core : 89mm Date 11.6.07 12.6.07 Symbolic Log Description Depth (m) Level (m ) Sample, Test or Core Recovery % Depth (m) of Sample, Test or Core Run R.Q.D. % (S.C.R. %) Fracture Index (no. per metre) S.P.T. N Value Water Casing Date 9.80 75 N 9.20 9.80 0 (9) 20 50 for 25mm pen. 12/6 Comments & Notes Inspection pit dug to 1.20m. Standpipe installed in gravel cell, 6.30-9.80m. Water standing at 2.47m bgl on 13.6.2007. Client DEVON COUNTY COUNCIL FSLS001a - Amended January 2005 U B D W N K Undisturbed Sample (U100) Bulk Disturbed Sample Disturbed Sample Water Sample Standard Penetration Test Falling Head Permeability Test Logged by NS Checked by JR RQD Rock Quality Designation SCR Solid Core Recovery Groundwater First Encountered Standing Water Level Depth of Casing V Insitu Vane Shear Test Scale Job Ref. 1:50 2962 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

Site/Project Name RIVER EXE CROSSING, TIVERTON Grid Ref. Ground Level m BOREHOLE BH2 Method Machine Sheet Window Sampling : 0.00-2.70m Rotary Coring (water flush) : 2.70-10.00m Comacchio Pioneer 305 1 of 2 Contractor GEOTECHNICAL ENGINEERING LTD Diameter Core : 89mm Date 12.6.07 13.6.07 Symbolic Log Description Depth (m) Level (m ) Sample, Test or Core Recovery % Depth (m) of Sample, Test or Core Run R.Q.D. % (S.C.R. %) Fracture Index (no. per metre) S.P.T. N Value Water Casing Date Turf over brown, sandy, clayey TOPSOIL Loose to medium dense, brown, slightly gravelly, silty SAND with rootlets 0.10 12/6 Medium-dense - dense, orangey brown, clayey, sandy, sub angular - sub rounded, GRAVEL 1.40 N D 1.20 1.30 15 D 2.00 Becoming very clayey below 2.5m. Very dense, grey brown, sub-rounded GRAVEL with cobbles of sandstone and some sandy clay in lower levels 2.70 75 ND 100 2.50 2.70 3.00 0 (0) 0 (0) NI NI 50 for 100mm pen. Moderately to slightly weathered, pinkish grey MUDSTONE. Moderately weak - moderately strong. Bedding dips 15-20 o, very thinly to thinly bedded, stepped-smooth. Joints strike oblique to bedding, dip 65-85 o, closely spaced, planar-smooth with some clay infill 3.60 63 D 93 N 100 3.80 4.00 4.50 0 (0) 0 (0) 0 (15) NI HF 50 for 35mm pen. 12/6 13/6 N 100 5.80 0 (0) 50 for 25mm pen. 6.40 Slightly weathered, dark grey, fine grained SANDSTONE. Moderately strong, locally strong. Bedding dips 10-15 o, very thinly - thinly bedded, planar smooth, Joints dip 65-85 o, closely spaced, smooth-planar. 7.00 100 N 100 7.30 0 (17) 0 (90) 20 50 for 25mm pen. 20 Comments & Notes Inspection pit dug to 1.20m. Water standing at 3.10m depth at start of shift, 13.6.2007. Client DEVON COUNTY COUNCIL FSLS001a - Amended January 2005 U Undisturbed Sample (U100) B Bulk Disturbed Sample D Disturbed Sample W Water Sample N Standard Penetration Test K Falling Head Permeability Test N 8.80 50 for RQD Rock Quality Designation SCR Solid Core Recovery Groundwater First Encountered Standing Water Level Depth of Casing V Insitu Vane Shear Test Logged by Checked by Scale Job Ref. NS JR 1:50 2962 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

Site/Project Name RIVER EXE CROSSING, TIVERTON Grid Ref. Ground Level m BOREHOLE BH2 Method Machine Sheet Window Sampling Rotary Coring (water flush) : : 0.00-2.70m 2.70-10.00m Comacchio Pioneer 305 2 of 2 Contractor GEOTECHNICAL ENGINEERING LTD Diameter Core : 89mm Date 12.6.07 13.6.07 Symbolic Log Description Depth (m) Level (m ) Sample, Test or Core Recovery % Depth (m) of Sample, Test or Core Run R.Q.D. % (S.C.R. %) Fracture Index (no. per metre) S.P.T. N Value Water Casing Date 100 0 (25) 25mm pen. 10.00 N 10.00 50 for 25mm pen. 13/6 Comments & Notes Inspection pit dug to 1.20m. Water standing at 3.10m depth at start of shift, 13.6.2007. Client DEVON COUNTY COUNCIL FSLS001a - Amended January 2005 U Undisturbed Sample (U100) B Bulk Disturbed Sample D Disturbed Sample W Water Sample N Standard Penetration Test K Falling Head Permeability Test Logged by Checked by NS JR RQD SCR V Rock Quality Designation Solid Core Recovery Groundwater First Encountered Standing Water Level Depth of Casing Insitu Vane Shear Test Scale 1:50 Job Ref. 2962 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS

RESULTS OF INSITU PERMEABILITY TESTS

RESULTS OF LABORATORY TESTS

GENERAL NOTES

GENERAL NOTES 1. This report has been prepared for the exclusive use of the client named in the document. Copyright remains with Frederick Sherrell Limited. 2. This report, and interpretation or opinion has been prepared for the specific purpose stated in the document, and in respect of specific development proposals made available to Frederick Sherrell Limited by the client. This report should not be used for other schemes or adjacent sites without further reference to Frederick Sherrell Limited. 3. This report is based on ground conditions encountered in the exploratory holes and/or exposed to view at the site, together with the results of insitu and laboratory testing, as appropriate for the proposed development. There may be specific conditions hidden beneath the ground between exploratory hole locations or between existing exposures, which have not been taken into account in the report. 4. Opinions on the possible arrangement of strata between and beyond the locations of exploratory hole locations or existing exposures are for guidance only, and are subject to risk of undiscovered variations in the ground. Supplementary investigation should be implemented where accurate interpolation or extrapolation is critical. 5. Methods of construction and/or design proposals other than those discussed in the report should be assessed in respect of the available data, and supplementary investigation carried out if necessary. 6. Groundwater conditions recorded during the investigation may be affected by the method and speed of boring, drilling or excavation, and they may vary due to seasonal, tidal or other influences. Page 1 of 1 FSLS008 Amended May 2004 FREDERICK SHERRELL LTD CONSULTING ENGINEERING GEOLOGISTS AND GEOTECHNICAL ENGINEERS