Scanning Surface Inspection System with Defect-review SEM and Analysis System Solutions



Similar documents
Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc.

h e l p s y o u C O N T R O L

To meet the requirements of demanding new

Developments in Photoluminescence Characterisation for Silicon PV

It has long been a goal to achieve higher spatial resolution in optical imaging and

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Coating Thickness and Composition Analysis by Micro-EDXRF

Smart Card Security How Can We Be So Sure?

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

MACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society

DualBeam Solutions for Electrical Nanoprobing

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Usage of Carbon Nanotubes in Scanning Probe Microscopes as Probe. Keywords: Carbon Nanotube, Scanning Probe Microscope

View of ΣIGMA TM (Ref. 1)

STM and AFM Tutorial. Katie Mitchell January 20, 2010

Raman spectroscopy Lecture

Optimao. In control since Machine Vision: The key considerations for successful visual inspection

The Basics of Scanning Electron Microscopy

Encoders for Linear Motors in the Electronics Industry

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

2 Absorbing Solar Energy

Near-field scanning optical microscopy (SNOM)

3D Raman Imaging Nearfield-Raman TERS. Solutions for High-Resolution Confocal Raman Microscopy.

Keysight Technologies How to Choose your MAC Lever. Technical Overview

History

CREOL, College of Optics & Photonics, University of Central Florida

FTIR Measurement Data Storage and Control Thin Film Sample Measurement Methods and Precautions ---5 Question ---8

Preface Light Microscopy X-ray Diffraction Methods

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Flat-Field IR Mega-Pixel Lens

Raman Spectroscopy Basics

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

BD-R 25GB BD-R 50GB. Write-once Blu-ray Disc. Write-once Blu-ray Disc. BD-RE 25GB Blu-Ray BD-RE 50GB

Automated Optical Inspection is one of many manufacturing test methods common in the assembly of printed circuit boards. This list includes:

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

Atomic Force Microscope

LabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:

DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm

X-ray thin-film measurement techniques

European bespoke wafer processing & development solutions for : Grinding, CMP, Edge Treatment, Wafer Bonding, Dicing and Cleaning

PCB Component Placement Inspection

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

Lenses and Apertures of A TEM

Practice of M2M Connecting Real-World Things with Cloud Computing

nanovea.com MECHANICAL TESTERS Indentation Scratch Wear

Recent Technologies in Nuclear Power Plant Supervisory and Control Systems

FRT - setting the standard

Laser sintering of greens compacts of MoSi 2

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Application Report: Running µshape TM on a VF-20 Interferometer

DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Major LED manufacturing trends and challenges to support the general lighting application

Figure 1 Wafer with Notch

Zero Width Glass Cutting with CO 2 Laser

Plastic Film Texture Measurement With 3D Profilometry

Physics 441/2: Transmission Electron Microscope

Nanoscale Resolution Options for Optical Localization Techniques. C. Boit TU Berlin Chair of Semiconductor Devices

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Faszination Licht. Entwicklungstrends im LED Packaging. Dr. Rafael Jordan Business Development Team. Dr. Rafael Jordan, Business Development Team

Results Overview Wafer Edge Film Removal using Laser

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

Lecture 4 Scanning Probe Microscopy (SPM)

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Prototyping to Production

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

Integrated Plant Management System for Meeting Operational Changes in Drug-manufacturing Industry Due to Revision of Pharmaceutical Laws

pb tec solutions GmbH, Max-Planck-Str. 11, Alzenau (Germany) Tel.: Fax:

Sandia Agile MEMS Prototyping, Layout Tools, Education and Services Program

Bruker Stylus and 3D Microscope Systems Solutions for Semiconductor Applications

Total Hot Spot Management from Design Rule Definition to Silicon Fabrication

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

Chapter 4 COATINGS Full Reflective Coatings:

Sputtered AlN Thin Films on Si and Electrodes for MEMS Resonators: Relationship Between Surface Quality Microstructure and Film Properties

Metrology of silicon photovoltaic cells using coherence correlation interferometry

Optical Methods of Surface Measurement

Ultra-High Density Phase-Change Storage and Memory

MICRO DROPLET GENERATION TECHNOLOGY

Winbond W2E512/W27E257 EEPROM

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

Luminescence study of structural changes induced by laser cutting in diamond films

Non-Contact Vibration Measurement of Micro-Structures

Surface Profilometry as a tool to Measure Thin Film Stress, A Practical Approach. Gianni Franceschinis, RIT MicroE Graduate Student

Motion and Positioning

Lapping and Polishing Basics

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

LabRAM HR Evolution. Research Raman Made Easy!

Making Better Medical Devices with Multisensor Metrology

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Automotive Applications of 3D Laser Scanning Introduction

Microscopy: Principles and Advances

Transcription:

Scanning Surface Inspection System with -review SEM and Analysis System Solutions 78 Scanning Surface Inspection System with -review SEM and Analysis System Solutions Hideo Ota Masayuki Hachiya Yoji Ichiyasu Toru Kurenuma OVERVIEW: Data obtained from wafer-surface inspection tools are limited to defect maps, defect number, etc. In any case, in order to swiftly execute measures to decrease the amount of defects, it is very important to determine where the defects are being generated. Accordingly, more concrete information on defects, such as shape and constitution data, is becoming more necessary. Hitachi High-Technologies Corporation is therefore offering a line-up of wafer-surface defect inspection tools and review scanning electron microscopes, and Hitachi Kenki FineTech Co., Ltd. is offering a line-up of atomic-force microscopes. In the present work, a system of improving yields by providing surface-analysis information about unpatterned silicon wafers called smart root cause analysis was developed. From now onwards, although defect observation based on the output coordinates from surface inspection of unpatterned silicon wafers is extremely difficult owing to a lack of an alignment basis, the developed system can address this difficulty and make a key contribution to crucial defect countermeasures with high efficiency. INTRODUCTION APPLICATIONS of unpatterned silicon-wafer substrates have two broad classifications. The first (fundamental) application is the inspection for starting material before a circuit pattern is formed on the substrate surface, and a semiconductor device is processed. In the second, defects generated by semiconductor device-processsing equipment namely, film-deposition equipment, etching tools, CMP (chemical-mechanical polishing), and cleaning equipment are investigated. In the former case, the wafer is distinguished as a prime wafer, and in the Smart Root Cause Analysis From defect detection to cause pinpointing Work flow of measures for reducing surface defects Inspection review -generation cause pinpointing Measure SEM image (2D) EDS analysis Information on the countermeasure is provided. map Wafer-surface defect-detection tool SSIS: scanning surface inspection system SEM: scanning electron microscope -review SEM AFM image (3D) Wide-area AFM EDS: energy dispersive X-ray spectrometer AFM: atomic force microscope Cause process Cause tool Prompt analysis of defect mechanism Goal Fig. 1 Linkage of Surface Inspection System and -review SEM. By defect-review SEM based on defect-location coordinates obtained from SSIS and by observation, classification, and EDS elemental analysis or 3D observation with AFM, data that contributes to improving yields of customers production systems are provided.

Hitachi Review Vol. 55 (2006), No. 2 79 LINKAGE OF SSIS AND DEFECT-REVIEW TOOLS -review SEM Although information obtained from SSIS is restricted to defect maps, defect number, etc., in order to swiftly carry out measures for reducing defects, it is important to find out where the defects were generated. This location is thus determined by defect inspection. Based on the location coordinates obtained from this inspection, defect observation by highlatter case, the wafer is distinguished as a test wafer, a process monitor wafer or a dummy wafer. As regards the amount of test wafers consumed, defect measurement using test wafers is widely performed with about the same number of wafers as platform wafers used in processing semiconductors. In line with the trend of device scaling-down, the object size in required defect measurement is getting smaller year by year, and detection and analysis of defects are getting even tougher. Concerning the defect-analysis method used for test wafers, analyses of wafer-transport particle and process-generated particle are carried out. Analysis on wafer-transport particle PWP (particles per wafer pass) is the operation of investigating particle that becomes attached to a wafer when it is in actual processing equipment and when it is transferred between processes. Analysis on process-generated particle PIDs (process-induced defects) is the operation of investigating defects generated after wafer processing TABLE 1. Object of Surface-defect Analysis, and Object Unpatterned Wafer and User Surface-defect analysis requires many users involved in semiconductor production. Aim PWP measurement (wafer transportation dust) PID measurement (process generated dust) Surface-defect measurement of silicon wafer PWP: particle per wafer pass Object unpatterned wafer Coated wafer Device manufacturer Equipment and materials supplier Wafer manufacturer PIP: process-induced defect User such as moving wafers under actual process conditions such as film formation (i.e. dummy deposition) (see Table 1). In the rest of this paper, equipment for detecting wafer defects is described, and the above-mentioned analysis methods are explained (see Fig. 1). SSIS (SCANNING SURFACE INSPECTION SYSTEM) As regards defects on unpatterned silicon wafer substrates, the principle of laser scattering is applied in detecting the defects. The detection principle utilized in Hitachi High-Technologies s SSIS is shown schematically in Fig. 2. This defect-detection principle is as follows: a laser is illuminated onto the wafer surface from above, scattered light from a defect is collected by a receiving lens, and the scattered light is converted to an electrical signal by a detector. The wafer is set on the rotating stage, and by moving the stage in the radial direction while it rotates, the whole wafer surface can be inspected at high speed. And by fixing an encoder to the stage, positional data of the wafer defect can be obtained. The attainable sensitivity of our latest model of SSIS is 36 nm on a bare wafer surface. Inspection-results display (defect map) Fig. 2 Overview of Detection by SSIS. A laser is illuminated on the bare wafer, and defects are detected at high speed. Laser illumination Scattering Receiving lens Detector Wafer Wafer Revolution Shift from wafer center to perimeter Wafer position Radial-direction moving stage data Shift from wafer center to perimeter detected signal A/D converter Signal processing Data processing ( XY coordinates) A/D: analog-to-digital

Scanning Surface Inspection System with -review SEM and Analysis System Solutions 80 Y O : Alignment points Fig. 3 Example of Alignment of Bare Wafer. A total of five points (three points on the periphery and two at the mouth of a V- notch) are aligned. magnification tools, such as SEM (scanning electron microscope), is an extremely effective approach. Under these circumstances, Hitachi s latest defectreview SEMs were developed for reviewing at high efficiency in a short time the vast amounts of inspection results obtained from the improvedsensitivity defect-inspection tools in use over recent years. Problems Regarding Review of Unpatterned Wafers The four main methods used in SSIS and defect analysis are given as follows: (1) detection by SSIS, and output of defectlocation coordinates (2) Coordinate matching alignment of SSIS tool and review SEM (see Fig. 3) (3) search and observation by review SEM (4) analysis by EDS (energy dispersive X-ray spectrometer) (i.e. elemental analysis) While these methods are recognized as effective for defect analysis, in execution of defect observation, there is a barrier to reacquiring defects by the methods on the SEM side, i.e. (2) and (3) above. In the case of a patterned wafer, a chip die origin is used as an alignment point, and since the alignment can relatively easily come off, defects are easy to review. However, with an unpatterned silicon wafer, since a unique alignment method is used for fixing the profile of a wafer, it is difficult to get high-precision matching between the coordinate system on the inspection-tool side and that on the review SEM side. Wide-FOV Optical-microscope Function To address the above-described issues, Hitachi High-Technologies has fitted its defect-review SEMs with a function for wide-view optical microscope, thereby vastly improving the efficiency of observation of bare wafers with large alignment error (see X Inspection Incorporating a function for wide-fov optical microscope significantly shortens search time. FOV: field of view Fig. 4 Making Observation of Bare Wafer Surface More Efficient by Wide-view Optical Microscope. Observation efficiency is significantly improved (about 100 times). Fig. 5 FOV of Wide-FOV Optical Microscope. s can be searched for over a wide-fov. Image from wide-fov optical-microscope 200 µm Coordinate error during normal measurement mode of wide-fov optical-microscope Alignment/searching observation solutions SEM image (low magnification) Observation FOV of wide-fov optical microscope 600 µm FOV of standard SEM (low magnification) 10-µm level Required time in conventional observation Example of coordinate-output error from defect-detection device to review SEM SEM image (high magnification) 0.16 µm FOV: 600 µm FOV: 13.5 µm FOV: 2.25 µm Fig. 6 Example of Observed by Using Wide-FOV Optical-microscope Function. First, defects at the macro level are found by optical microscope, then micro observations are done by SEM. Figs. 4 and 5). It is currently possible to automatically pick up defects with a size of 70 nm in a 600-µm 2 FOV (field of view) on a wafer surface. This gives enough leeway for a condition where detection of total alignment error with standard defect-detection tools of less than 200 µm, and matching with each detection tool are possible (see Fig. 6). 200 µm

Hitachi Review Vol. 55 (2006), No. 2 81 EDS system Automataic Hitachi s own methods of displaying substance names identification Candidate substance names from the spectrum are shown in plural. Powerful assistance for specifying substances is realized. Acquired spectrum Comparison with spectral pattern stored in library 1. SUS316 2. SUS304 3. FeTiO 3 Substance-name display 4-way-splitting photodiode Optical microscope Depth probe XY stage Laser oscillator Material AFM mode Cantilever Atomic force Wide mode Z controller PC XY controller XYZ slow-motion mechanism Fig. 7 Principle of Pinpointing Material by EDS. The obtained spectral pattern is compared with one recorded in a library. Each material is then shown in order of high concordance ratio. Fig. 8 Block Diagram of Hitachi s AFM While detecting atomic force corresponding to the spring constant of a cantilever, the surface of the material is scanned. Fig. 9 Surface-defect Analysis by Hitachi s AFM (a), Example of 3D Surface Observation (b). The procedure for surface analysis of a bare wafer, the operation screen, and an example of voiddefect output are shown. FD: floppy disk AFM defect review: data link -data reading from FD Wafer alignment (wafer edge) -coordinate display Review defect designation Stage automatically moved to defect location confirmation and measurement-position fine adjustment by optical microscope AFM measurement review (a) Complete map Operation screen AFM image of a bare wafer clutch (b) Enlargedarea map Elemental Analysis by EDS In regards to Hitachi s defect-review SEM series, as an analysis function, where elements included in a defect are identified, EDS can be fitted optionally. An electron beam is irradiated onto the target defect, the generated X-ray energy is detected, and the elements in the defect are identified. In addition, by comparing the detected elemental composition with substances recorded in a library, the physical substance of the defect can be identified. This function is a powerful way of examining the generation of defects in conjunction with classifying them (see Fig. 7). SURFACE ANALYSIS BY AFM 3D Surface Shape Analysis Although surface defects can be conveniently reviewed by defect-review SEM, in the case of observation of 3D surface shape, use of AFM (atomic force microscope) can achieve resolution in the order of 0.1 nm in the vertical direction (see Fig. 8). As the objects of surface observation by AFM, micro-scratching formed during CMP, COP (crystaloriginated pit) formed during processing of silicon wafers, and typical void defects with openings of less than 100 nm are often mentioned. Linking Coordinates of SSIS and AFM By equipping a coordinate-link function with an AFM, it is possible to observe defects identified by SSIS by AFM. The analysis procedure is shown in Fig. 9 (a). Moreover, examples of the operation screen and the AFM output image are given in Fig. 9 (b). Haze Data and AFM In regards to SSIS, as well as detection of point defects on a surface, a function for mapping surface-

Scanning Surface Inspection System with -review SEM and Analysis System Solutions 82 dispersion data of parts without defects is available. Haze information the processed scattering signals that are lower than the minimum detection sensitivity is utilized through a linkage with highresolution AFM, so even more detailed analysis of a surface is possible. Further study on use of haze information is our future challenge. CONCLUSIONS This paper described defect detection of unpatterned wafers by integration of inspection and analysis tools and analysis methods. From now onwards, along with the continuing scaling down of devices, thorough investigation of the generation cause of defects which have an impact on device yields will become even more difficult. Along with improving the function of individual machines in our line-up of inspection and analysis tools, Hitachi Group will enhance its development of applications that combine these tools in order to meet the future needs of the information society. REFERENCES (1) H. Koyabu et al., In-line Atomic Force Microscope for Semiconductor Process Evaluation, Hitachi Hyoron 84, pp. 271-274 (Mar. 2002) in Japanese. (2) M. Nozoe et al., Inspection and Analysis Solutions for Highquality and High-efficiency Semiconductor Device Manufacturing, Hitachi Hyoron 86, pp. 465-470 (July 2004) in Japanese. ABOUT THE AUTHORS Hideo Ota Joined Hitachi Electronics Engineering Co., Ltd. in 1979, and now works at the Application Technology Department, the Semiconductor Process Control Systems Sales Division, Hitachi High-Technologies Corporation. He is currently engaged in the marketing of semiconductor inspection system. Mr. Ota is a member of The Japan Society of Applied Physics (JSAP), and can be reached by e-mail at: ohta-hideo@nst.hitachi-hitec.com Masayuki Hachiya Joined Hitachi Electronics Engineering Co., Ltd. in 1980, and now works at the Optical Inspection Systems Design Department, Naka Division, the Nanotechnology Products Business Group, Hitachi High-Technologies Corporation. He is currently engaged in the development of wafer inspection system, and can be reached by e-mail at: hachiya-masayuki@naka.hitachi-hitec.com Yoji Ichiyasu Joined Hitachi, Ltd. in 1984, and now works at the Application Technology Department, the Semiconductor Process Control Systems Sales Division, Hitachi High-Technologies Corporation. He is currently engaged in the marketing of semiconductor inspection system, and can be reached by e-mail at: ichiyasu-yoji@nst.hitachi-hitec.com Toru Kurenuma Joined Hitachi Construction Machinery Co., Ltd. in 1982, and now works at the Design Department II, the Development & Production Division of Hitachi Kenki FineTech Co., Ltd. He is currently engaged in the design and development of an AFM system. Mr. Kurenuma is a member of The Japan Society of Mechanical Engineers (JSME), and can be reached by e-mail at: kurenuma82@hitachi-kenki.co.jp