Product Showcase. A Division of Bionix Since 1993 TESTING MADE EASY. SAFETY MADE SIMPLE.



Similar documents
ACL 395 Resistivity Meter

Element D Services Plumbing

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Tablet Management Rack 16

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

PAT Tester Printers and Barcode Scanners

ACL 800 MEGOHMMETER OPERATION MANUAL

Acellus Natural 3D Tablet

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

KNC Model 3666 Automatic Pressure Calibration System

MOBILE WORKPLACE AND PORTABLE POWER SYSTEMS

OxySense Portable Series Instrument Quick Start Guide

ROOM SCHEDULING SYSTEM

How To Install A Power Supply (Uplast) With A Battery Pack

3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!

Lava. Precision Solutions. Site Planning and Installation Guide

Cabinets 101: Configuring A Network Or Server Cabinet

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Anthro Tablet Charging Cabinets

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Shunt lock function 3066

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

EKOS Cart. Instructions for Use

WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world

Using a Tablet with the AIM and VNA

QuickSpecs. HP 480/277 Volt Solutions. Overview

Mobile Data Power Model: MDP-25

CNC Tool Storage Solutions

Printers and Barcode Scanners

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

Rogers Smart Home Monitoring QUICK START GUIDE ROG_6093_QST_GDE_EN.indd 1 9/22/12 8:29 AM

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multi-Range Programmable DC Power Supplies 9115 Series

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Component Series Racks Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Model #: SMART2200CRMXL

StorTrends 3400 Hardware Guide for Onsite Support

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

STAY COMPLIANT. MAKE P-TOUCH AN ESSENTIAL PART OF YOUR KIT.

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

EMS Service Administrator s Guide for Activation and Troubleshooting

HP UPS R1500 Generation 3

Operating Instructions

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

CNC Tool Storage Solutions

Installer guide. Release 2.2

Machine Tool Inspection & Analyzer solutions

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Care ExchangeTM MIDMARK CARE EXCHANGE TM WORKSTATIONS. Care

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

T a b l e o f C o n t e n t s

46120-F0 Solar Energy Training System

Fitness Wristband Active TX 38

Zip40 Charging Cart. User's Guide. Components. Tools Needed ENGLISH. For the latest User Installation Guide please visit:

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

CRYPTOPAY QUICK START GUIDE

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

High Power Programmable DC Power Supplies PVS Series

UNIVERSAL BLUETOOTH KEYBOARD CASE FOR TABLETS 7-8 INCHES

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Product Specification instalert Rapid Messenger Variable Message Sign

Wireless Network Guide

Quick Start Guide For Vera Small Business Solution

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

The Fundamentals of Spring Testing

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SMART Board 8055i and 8055i-SMP

Technical Update TAA.TU Rev. 1

Thinix ipad Kiosk Hardware and Accessories

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Guide for wireless environments

White Paper Barcoding

SanDisk Connect Wireless Flash Drive QUICK START GUIDE

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Multi-Function Ground

MANUAL PC1000R

The Third Rail System User Manual

CNC Tool Storage Solutions

Full 1080p Network Video Recorder with 2TB HDD & 8 Night Vision 1080p HD IP Cameras

BlueGate. Your easy to use reference for getting the most out of your product USER GUIDE. Enjoy FREE REGISTRATION

Windows 10.1 Tablet (UB-15MS10 and UB-15MS10SA) FAQ December 2014

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Research-Grade Research-Grade. Capture

Toroidal Conductivity Sensor

Data Logging Solutions from Lascar Electronics

Philips PageWriter Touch ECG System

ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

Mirador. Features include: Applications:

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Automatic Phone-Out Home Monitoring Systems

Transcription:

The Smart Way to Manage Your Testing National Safety Technologies manufacturers and distributes testing and measurement devices for healthcare facilities that make required testing easy. A Division of Bionix Since 1993 Product Showcase NST knows you are committed to complying with The Joint Commission, NFPA and FDA requirements and guidelines for safety at your facility. NST is here to provide you with the tools to do so. NST products are faster, easier and more automated than any other product available today. You will achieve greater accuracy, increased reliability and the peace of mind knowing your facility will pass inspection for safety requirements. Utility Safety and Compliance Medical utility testing is an important fact of life for healthcare facilities like yours. The Joint Commission and the NFPA developed strict standards for utility operations within healthcare facilities. In addition, some manufacturers of utility components recommend testing as frequently as every six months. That is where National Safety Technologies (NST) comes in. Since 1988, NST has helped facilities like yours cut down on the time and resources it takes to do the required testing; by as much as 50 percent or more. And that means substantial cost savings for you. With NST analyzers, compliance has never been so easy. Bed System Entrapment Measurement For 20 years, the FDA has received reports in which vulnerable patients have become entrapped in hospital beds while undergoing care and treatment in healthcare facilities. In response to these reports, the FDA, along with the US Dept. of Veterans Affairs, The Joint Commission, ECRI Institute, NFPA and other patient advocacy groups and industry representatives formed the Hospital Bed Safety Workgroup. The HBSW worked to develop a system for ensuring patient safety in hospital bed systems, which was then published as a guidance document by the FDA in 2006. Along with the guidance document the HBSW developed the Bed System Measurement Device to test bed system for compliance with the guidance document. The HBSW then chose NST to be the sole manufacturer of this innovative device. Proven Technology Hundreds of healthcare providers across the country, large and small, are using NST analyzers and measurement devices as part of their internal testing programs. NST customers range from 30-bed to 1,300 bed facilities. TESTING MADE EASY. SAFETY MADE SIMPLE. This group of customers includes: Johns Hopkins Hospital The Cleveland Clinic UCLA Healthcare Duke University Hospital Mayo Clinic Children's Hospital of Philadelphia Kaiser Permanente Health System Hospital of the University of Pennsylvania The New York Hospital Brooke Army Medical Center Many VA and USAF Medical Centers

R7000 Electrical Receptacle Analyzer R7000 Electrical Receptacle Analyzer The New R7000 Electrical Receptacle Analyzer is an advanced device that will drastically simplify your electrical receptacle testing. The R7000 facilitates compliance and promotes safety while dramatically reducing the time spent testing and generating required reports. An electrical receptacle is tested in a matter of seconds. Test results are displayed with confirmation of whether the results comply with established safety standards. The new detachable reference cord offers two different test routines: (1) an expanded program with comparative testing (2) a simplified program for troubleshooting and quick checks. Your testing frustrations have been eliminated in this convenient package. It s easy to use, yet packed with power. A fast, labor saving way to meet NFPA Code 2012 Easily generates reports recognized by The Joint Commission Touchscreen allows trouble-free data entry. Large display shows multiple test results. Preloading capabilities eliminate repetitive typing. Time and date are automatically recorded. Optional reference cord allows either comparative or simplified test routines. Report Commander software creates fully formatted reports. Sizable memory stores test results for up to 10,000 outlets. Specifications: Mode of Operation - Automated testing and data collection Tests Performed - Standard OKX Test to Check Receptacle Wiring Polarity Isolated Power Wiring Line Voltage Phase Relationship Between Receptacles Neutral to Ground Voltage Neutral to Ground Resistance Ground to Ground Voltage Ground to Ground Resistance Contact Tension (Gripping Force) of Hot, Neutral and Ground Prongs Weight In Use: Analyzer and Test Probe Approx. 4 lbs. In Use: Analyzer, Test Probe and Reference Cord Simply plug the R7000 into a wall Approx. 5 lbs. receptacle & receive analysis in seconds. In Storage: Analyzer, Test Probe and Reference Cord Approx. 13 lbs. Size Analyzer: 9" W x 2 ¾" H x 7 ½" D Storage Case: 18" W x 5 ½" H x 14" D Power In Use with Reference Cord: Line Voltage 115VAC, Frequency 60Hz In Use without Reference Cord: Rechargeable Battery Approx. 10 hrs. of operation per charge Hardware Included: Analyzer with touchscreen display Test Probe for 115-volt electrical receptacles Optional reference cord for comparative testing Independent charging cable USB cable for uploading/downloading Shoulder/neck straps Software installation disc and user's guide Samsonite hard briefcase Software Included: Newly developed Report Commander data/template collection and reporting software. Warranty: With the purchase of the R7000 Electrical Receptacle Analyzer, NST offers a one-year warranty on all parts and labor. Key Benefits: Automated testing reduces likelihood of errors. Up to 12 tests per receptacle ensures safety compliance and facilitates troubleshooting. Automatically-generated or user-created templates eliminate tedious and redundant receptacle documentation. Easily generates NFPA compliant reports. Saves money compared to lengthy in-house test procedures or hiring outside specialists. Calibration: NST Analyzers are calibrated to NIST traceable standards before they leave the NST warehouse. Each NST analyzer comes with a 30-day limited money back guarantee. *Samsonite is a registered trademark of Samsonite Corporation. Scan here for demonstration video

G4000 Medical Gas Outlet Analyzer G4000 Medical Gas Outlet Analyzer The G4000 Medical Gas Analyzer completes multiple tests in seconds while simultaneously developing reports recognized by The Joint Commission. The G4000 is operated by Samsung Galaxy Tab 31 for Android using Bluetooth technology and calibrated according to NIST Standards. Key Benefits: Instantly create reports recognized by The Joint Commission Wi-Fi capable for wireless report printing and distribution Faster and more efficient than hand-held devices Light weight, compact design makes easy to use and carry Provides compliance to NFPA 99 Code for Gas and Vacuum Systems* *NFPA 99 codes 5.1.12.3.10-11, 5.1.14.4.1, 5.1.15, Annex 5.1.15 1 Tablet may vary based on manufacturer availability. Specifications: Mode of Operation: Samsung Galaxy Tab 31 for Android via Bluetooth Outlet Tested: Oxygen, Medical Air, Nitrous Oxide, Carbon Dioxide, Nitrogen, Vacuum, WAGD (Waste Anesthetic Gas Disposal) Tests Performed: Expected/Detected Gas, Static Pressure, Flow Test, Pressure Drop, Gas Concentration, Transient Flow Test for Critical Care Areas Pressure Flow: Maximum Static Pressure: 220 PSIG Maximum Flow Rate: 180 LPM Weight: In Use: 5 lbs In Storage: 14 lbs Size: Analyzer 9" W x 2 ¾" H x 7 ½" D Storage Case 18" W x 5 ½" H x 14" D Hardware Included: Samsung Galaxy Tab 3 1 for Android Gas Analyzer Interface Set of quick-disconnect adapters (mate with hospital medical gas outlets) Charging Cable Shoulder/Neck Straps User s Guide Storage Briefcase Software Included: MedGas Commander for Android Application Warranty: With the purchase of the G4000 Medical Gas Outlet Analyzer, NST offers a one-year warranty on all parts and labor. 2 Guarantee: Each NST analyzer comes with a 30-day limited money back guarantee. Tests Performed NEW Transient Flow for Critical Care Areas NEW Gas Concentration Expected Gas / Detected Gas Static Pressure Flow Test Pressure Drop Outlets Tested NEW Carbon Dioxide NEW Waste Anesthetic Gas Disposal (WAGD) Medical Air Nitrous Oxide Nitrogen Oxygen Vacuum Calibration: NST Analyzers are calibrated to NIST traceable standards before they leave the NST warehouse. Annual calibrations are required. 1 Tablet may vary based on manufacturer availability. 2 Parts and labor warranty limited to the analyzer unit. Tablet is warrantied based on manufacturer terms. Scan here for more information

B4000 Bed System Measurement Device B4000 Bed System Measurement Device In 2006 the FDA, with the help of the Hospital Bed Safety Workgroup issued a guidance document entitled, Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment. These guidelines aid in the design of new bed systems and assess entrapment risks associated with hospital bed systems. In response to these guidelines, National Safety Technologies offers the innovative Bed System Measurement Device. The Bed System Measurement Device offers you the following Complies features and benefits: with Health Canada Guidance Document The validated test tool for assessing a bed system s conformance to the FDA guidance. The only device specifically designed to test the four critical entrapment zones of a bed system. Allows a two-person team to test a complete bed system within 15 minutes. Easy to read Pass/Fail indicators located on the device. Safety strap designed to prevent the device from falling on your feet during testing. Product Offering: Cone and Cylinder Tool The Cone and Cylinder Tool are used together for testing Zone 4 or easily detach to allow use of the Cone only for testing Zones 1-3. Key Dimensions: The diameter of the large end of the cone is the width of a small adult head or 4 ¾ inches (120 mm). The diameter of the cylinder is the size of a small adult neck or 2 ⅓ inches (60 mm). The cone and cylinder together is the weight of a small adult head and neck or 15 lbs. Easy to read red and green zones on the cylinder section for measuring side rails Easy to read lines on the cone to measure mattress compression A safety strap to prevent the device from falling to the floor Attachment ring for spring scale Cone and Cylinder Tool 4 Critical Entrapment Test Zones (As determined by the Hospital Bed Safety Workgroup): There are 4 tests designed to measure gaps in the bed system where a patient can become entrapped. Zone 1 - Within the bed rail itself. Zone 2 - Between the bottom of the rail, the top of the mattress and between the rail supports. Zone 3 - Between the outside edge of the mattress and the inside of the side rail. Zone 4 - Between the top of the compressed mattress and the bottom of the rail, at the end of the rail. Scale The scale is used to apply 12 lbs. of force to the cone for testing Zones 1 and 2. Large, clearly marked scale A hook used to connect the scale to the Cone tool FDA Guidance Document available at: http://tinyurl.com/nst-bed-fda Health Canada Guidance Document available at: http://tinyurl.com/nst-bed-canada Scan here for demonstration video

NST Testing Cart NST Testing Cart The NST Testing Cart (Product #C1000) offers a sturdy, easily maneuverable work surface for your testing needs. It is small enough to fit into tight spaces yet provides a generous work surface to log testing information and carry any tools or accessories you might need. What it Includes: Cart with extenders to reach standing height of 35" Test probe holder (only applicable with G3000) Velcro to secure analyzer (and laptop if included) Bin for adapters and/or other tools or supplies Optional Accessories: Dimensions: 22" d x 17" w x 35" h 2 ³ ₈ inch casters CD Holder Drawer (3"h) Handle 12" Straight Handle Metal Tray Hooks Shelf Mouse Shelf (Clamp on) Shelf Wire Base Surge Protector (Black) Scan here for more information 996 Old Eagle School Road Suite 1118 Wayne, Pennsylvania 19087 Email: sales@nst-usa.com Phone: 1.800.678.7074 Fax: 1.800.539.9319 www.nst-usa.com 2014 National Safety Technologies Rev. 3/2/15