The centrepiece of a complete anaesthesia workstation



Similar documents
Boaray 700 Anesthesia Machine

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

GE Healthcare. Aespire Essential performance Compact design

Anesthesia Solutions. Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

A ANESTHESIA SYSTEMS. intuitive effortless precise

Operator s Instruction Manual

DATA SHEET. Capnography option. November 2013 V2.2

Your personal anesthesia assistant DRÄGER PRIMUS

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

FLOW-i ANESTHESIA DELIVERY SYSTEM

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Impact Uni-Vent 754 Portable Ventilator

Aliseo Anesthesia system

Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care

Expand your view. IntelliVue MX600, MX700, and MX800 bedside patient monitors

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

The Anesthesia Ventilator

Vivo 50/60 PC Software Help (english), version Introduction. 3. Dialogs. 7. Year data view. 8. Alarm view. 2. User interface. 9.

IntelliVue to go. IntelliVue MX40 wearable patient monitor

Aestiva Anesthesia Machine. Technical Reference Manual

A COMPARISON OF THE COST OF INHALATIONAL ANAESTHESIA USING VARIOUS BREATHING SYSTEMS: IMPLICATIONS FOR THE DEVELOPNG WORLD

The Anesthesia Ventilator

Impact Uni-Vent 750 Portable Ventilator

Ventilators/Transport*

Artificial Ventilation Theory into practice

Trilogy accessory guide

Aespire View. User s Reference Manual. Software Revision 6.X

GE Healthcare. Welcome to the future of anesthesia Aisys * Carestation *

«The compact and mobile testing device for ventilators.»

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 60 Ventilator. Operator's Manual

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

The intelligent solution for the mobile ICU

The Puritan Bennett 980 Ventilator

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

D A cost effective monitor that meets your clinical needs VISTA 120

Built for peace of mind. IntelliVue MX550 patient monitor

Oxylog 3000 plus Emergency & Transport Ventilation

Carina Pocket Guide Software version 3.n. The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use.

Keeping pace with the point of care

When the point of care is on the move

Welcome to the future of anaesthesia.

Puritan Bennett 840 Ventilator User s Pocket Guide. Puritan Bennett 840 Ventilator Pocket Guide

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

MEDUMAT Easy CPR The Guiding Emergency Ventilator

For over 40 years, the leader in. nitrous oxide. equipment technology.

The column to efficient care DRÄGER GEMINA DUO

Networked versatility. IntelliVue MP60 and MP70 patient monitors

SimplyGo Quick-start guide

Agila Ceiling Supply Unit Medical Supply Units

Prima SP2 Anaesthetic Machine Range. Service Manual. Partnership for Life

Two Steps forward in Ventilation. Ernst Bahns. Because you care

AUSTRALIAN AND NEW ZEALAND COLLEGE OF ANAESTHETISTS ABN RECOMMENDATIONS FOR THE POST-ANAESTHESIA RECOVERY ROOM

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

STARKSTROM. clinical pendants. Excellence & Innovation in Medical Engineering

Battery Powered Digital Mass Flow Meters for Gases

High-intensity performance. IntelliVue MP90 patient monitor

Oxygen simplified EverFlo concentrators reduce the cost of oxygen therapy

Connected Care. Philips HeartStart connectivity and data management for EMS professionals

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

Veterinary Clinics and Hospitals

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Natural geothermal energy.

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 50 Ventilator. Service Manual. DOC-0004 Rev B. Sep 2012

Integrated Custom Systems

The bridge to more efficient care PONTA SUPPLY BEAMS

Mechanical Ventilation for Dummies Keep It Simple Stupid

Battery Powered Thermal Mass Flow Meters for Gases

Movita Ceiling Supply Unit Medical Supply Units

A passion for patients. Philips Patient Monitoring Services

S/5 Anesthesia Monitor. The clinician s choice

API Marine. BMS Presentation. Ballast Measurement Systems

Battery Powered Thermal Mass Flow Meters for Gases

Sleep Therapy I Ventilation I Patient Interface. Sleep Therapy. Sleep therapy solutions for every patient

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Titration protocol reference guide

MECHINICAL VENTILATION S. Kache, MD

PORTABLE, SELF-CONTAINED VENTILATION SYSTEM

Workspace and storage furnishings

GETINGE CLEAN MANAGEMENT SYSTEM

Mitos P-Pump. product datasheet

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

The Axial Flow Valve. Class 300/ SERIES

TRANSPORT OF CRITICALLY ILL PATIENTS

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

Aisys* CS 2 Advanced and Sustainable Anaesthesia Care NOT FOR USE IN THE UNITED STATES

Volume Guarantee New Approaches in Volume Controlled Ventilation for Neonates. Jag Ahluwalia, Colin Morley, Hans Georg Wahle

Dräger Globe-Trotter GT5400 Neonatal Transport

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

Managing workflow your way

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

Density/Specific Gravity/ Concentration Meter DMA 500

m a n u a l t é c n i c o

Thermal Mass Flow Meters and Controllers for Gases

ServoCare PRODUCTS AND ACCESSORIES CATALOG ISSUED OCTOBER 2004 CRITICAL CARE

Airway Pressure Release Ventilation

Transcription:

The centrepiece of a complete anaesthesia workstation IntelliSave AX700 anaesthesia machine

A slim design with rich functionality To develop the first Philips-branded anaesthesia machine, we listened to hospital staff from around the world, and added the broad expertise in anaesthesia delivery we have among our research and development, design, and clinical application specialists. The result is the IntelliSave AX700, an anaesthesia machine that is the centrepiece of a complete anaesthesia workstation solution from Philips, with an impressive number of high-end features. This includes support for low-flow and minimal-flow anaesthesia, and extensive ventilation capabilities, all packed in a slim and ergonomic, modern design. You can also opt for additional capabilities, such as advanced ventilation modes like Pressure Regulated Volume Target (PRVT), or special support for neonatal or heart-lung machine (HLM) scenarios. We can offer the option of a built-in Multigas Module to provide the feedback you need, unless you choose to make anaesthesia gas measurements with your patient monitor. Key advantages A platform ready to grow with your personal needs and advances in anaesthesia practice A compact, vertically integrated breathing system (IBS) that is easy to disassemble and reassemble for cleaning Space-saving design and ergonomic layout Touch screen-based user interface for an intuitive and easy operation Electronic gas mixer for exact control and display of gas mixtures Optional Multigas Module to monitor O2, N2O, CO2, RR, and an anaesthesia agent (with automatic agent identification) A high standard of built-in features to support patient safety 2 AX700

Safety first The IntelliSave AX700 is designed with safety in mind. The built-in battery backup has separate batteries for the user interface, gas mixer and ventilator. This enhances battery use and allows you to continue your anaesthetic delivery for up to 90 minutes, without interruption, even if external power fails. Even without any mains power or batteries, the critical functions are mechanically and pneumatically operated. This means you can manually anaesthetise and ventilate the patient using the vaporisers and an emergency oxygen flow from a pressurised supply. The electronic gas mixer, with a fresh gas flow of up to 20 litres per minute, has a rotameter-like display presenting the flow of O2 and the air or N2O mixture. The hypoxic guard function ensures the O2 / N2O mix always contains at least 25% oxygen, and cuts off N2O and sounds an alarm if the oxygen supply fails. Other safety features include: An adjustable, emergency fresh gas flow A fresh gas switch to redirect the fresh gas flow to the auxiliary fresh gas outlet for rapid switching between the IBS and an external breathing system An external, auxiliary O2 flow meter for quick availability of supplementary oxygen An integrated patient suction unit for immediate access A fast, semi-automatic self-test at start-up, to ensure the machine is working correctly Ventilation capabilities A wide variety of ventilation modes lets you match the ventilation requirements of patients from neonatal to the elderly. This includes the advanced PRVT ventilation mode, which combines the advantages of pressure-controlled and volume-controlled ventilation, by adjusting the ventilation parameters to protect the patient s lungs from barotrauma while trying to provide the desired tidal volume. Even for your smallest patients The optional Neonatal mode combined with PRVT can achieve tidal volumes down to 10 ml and lets you control even these tiny flows in steps of down to 1 ml. Ventilation modes: Volume-controlled ventilation (VCV) Volume-supported ventilation (VSV) Synchronised intermittent mandatory ventilation (SIMV) Pressure-controlled ventilation (PCV) Pressure-supported ventilation (PSV) Pressure-regulated volume target (PRVT) optional AX700 3

Convenience by design The ease of use starts well before you turn the machine on. The compact size and convenient mobility of the IntelliSave AX700 help it fit even in operating theatres where space is limited. It also helps you keep your workspace tidy with two drawers for user manuals, accessories and other items, and tabletop with integrated side rails and enough space for the anaesthesia record or syringes, and so on. It even has its own LED light you can adjust to illuminate the writing surface or other points of interest without distracting the surgeon. Despite its slim design, the IntelliSave AX700 includes several key functions as standard, such as the AGSS for gas evacuation. These remove the need to have separate systems beside or behind the machine. The IntelliSave AX700 anaesthesia machine can be delivered with a back bar for either Selectatec- or Draeger-style vaporisers, so you can reuse your existing vaporisers. It also has mounting interfaces for patient monitors and a second display (for example, for a second monitoring display or an anaesthesia information management system display), to add flexibility without adding unnecessary bulk. Applying extensive know-how on anaesthesia workflows and the layout of anaesthesia workspaces, we have grouped the controls and indicators for intuitive and fast access. Similarly, the 15 colour touch screen used to set the anaesthesia machine functions, and to display the settings and measured data (including waveforms, loops, trends, and system messages and alarms) is structured for easy usability and understanding. The screen also integrates measurements from the optional Multigas Module, which monitors O2, N2O, CO2, respiratory rate, and primary/secondary anaesthetic agents (with automatic agent identification). Getting to work Set up is simple too. Forget about time consuming, multiple-tube connections between the anaesthesia machine, breathing system, and patient. Our vertically-integrated breathing system (IBS) combines an ascending bellows, breathing system, and CO2 absorber in one compact unit. That means no tubing between the IBS and the machine, and only two hoses for inspiration and expiration between the IBS and the patient. The ascending bellows acts as a fast sign of leakage since, rather than drawing in air as hanging bellows do, it gradually collapses if there is leakage. The filling volume of up to 1500 ml provides suitable tidal volumes for adults, paediatrics, and neonates. The vertical design of the IBS makes it moisture-tolerant. As does the construction of the flow sensor which is insensitive to condensation. Available in reusable or disposable versions, the i-sorb CO2 absorber canister lessens the waste of unused soda lime thanks to its flow-optimised design. It even lets you replace the absorber canister while the machine is running, to minimise disruption to anaesthesia delivery. The volume sensor measures the inspiratory and expiratory flows. It connects to the input at the left of the machine. The placement of the sensor and connection near the patient contribute to an accurate reading, for better patient control. Once turned on, the ventilator makes control easy by compensating automatically for the fresh gas flow and compliance in the breathing system. The yellow inspiratory and expiratory valves let you quickly check the correct function. The Adjustable Pressure Limiting (APL) valve located immediately above the manual bag connection limits the maximum airway pressure in manual ventilation (MAN) and spontaneous breathing (SP). 4 AX700

Easy to own Smooth surfaces on the IntelliSave AX700 support easy cleaning and are designed to help you get ready for the next patient. The integrated breathing system, with only 13 components, can be taken apart for cleaning in under 60 seconds. The unambiguous design also prevents reassembly errors. The ease of maintenance is further enhanced by long intervals for preventive maintenance (once a year) which is possible through the reliability of the system. AX700 5

Your Anaesthesia Partner While we continue to support open systems that let you tailor solutions to your needs, with the new IntelliSave AX700 anaesthesia machine, you can now get your complete anaesthesia solution straight from Philips. That is, you can trust your anaesthesia equipment needs to a company renowned for quality, advanced technology, reliability and safety. This not only includes anaesthesia patient monitors, anaesthesia information management systems, and, of course, the anaesthesia machine, but now also offers a single point of contact for sales, training, support, and service. Philips provides a wide range of anaesthesia-specific IntelliVue patient monitors with anaesthesia-specific features and configurations, and measurement parameters relevant for anaesthesia, like EEG, Bispectral Index (BIS), or Neuromuscular Transmission (NMT). You can mount these monitors to the left of the IntelliSave AX700, to keep cables short, and make it easy to view when attending to the patient. There are also alternatives for mounting a second display to the right. This could be a second monitoring display. Or it could be our IntelliSpace anaesthesia information management system for decision and documentation support. This can run on a separate PC, or on the integrated PC (ipc) of an IntelliVue MX-series patient monitor. Of course, all our products integrate closely to become part of a single anaesthesia workplace. A data communication interface (available through the optional SmartLog communication port) lets you include data from the anaesthesia machine with other relevant patient information on the patient monitor display, or to communicate data to other hospital IT systems. 6 AX700

IntelliSave AX700 Dimensions (H W D) 1550 810 790 mm Weight 150 kg Fresh gas flow Electronic flow meters and flow control Total flow range: 0 20 L/min Vaporisers Back bar for two Selectatec- or Dräger-style vaporisers with interlock safety mechanism Integrated breathing system (IBS) Condensation insensitive, vertical design Fresh gas introduced after the inspiratory valve Absorber capacity Volume 1420 ml. Capacity approx. 880g soda lime Tidal volume 10 to 1500 ml (PRVT and Neonatal mode) 20 to 1500 ml (VCV) Respiration rate 4 to 80 bpm I:E ratio 3:1 to 1:9,9 Electronic PEEP 4 to 20 hpa (cmh 2 O) Inspiratory pressure PCV mode: 4 to 67 hpa (cmh 2 O) PSV mode: 4 to 50 hpa (cmh 2 O) AGSS 30 to 40 L/min Ventilation measurements Peak, Plateau, PEEP and Mean Pressure, Patient compliance, Tidal and Minute volume, Spirometry loop Integrated Multigas Module Up to 2 agents (with automatic agent identification), CO 2, O 2, N 2 O, Respiration rate Philips is committed to continuous innovation and will extend the IntelliSave platform to grow with your needs. Solid back up Philips also has a service portfolio that encompasses a range of customizable service contracts to ensure your equipment continues to meet its performance potential, and with as few interruptions as possible. We also offer value-added services such as training from our clinical application or technical specialists. For more information, please contact your Philips representative. AX700 7

Philips Healthcare is part of Royal Philips How to reach us www.philips.co.uk/anaesthesia anaesthesia@philips.com UK +44 (0) 1483 864766 Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 Not available in the US Please visit www.philips.com/anaesthesia 2012 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in the UK. 4522 962 8835