Fossil fuel heating equipment



Similar documents


Test Code: 8297 / Version 1

Evaluate, Clean, and Tune Guidance

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Annual Service Agreement

Customized Assessment Blueprint

Diagnostics for Mobile Homes: HVAC

80UHG. Service Literature

Air Conditioning Sign-Off Sheet

G670 Intermittent Pilot Ignition Controls

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

HVAC Processes. Lecture 7

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

, User s Manual

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation and Air Conditioning

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

High School Graduation years 2013, 2014, Unit/Standard Number

SL280UHV SERIES GAS FURNACE WARNING

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Flame Conductivity VS Flame Rectification Systems

Factory owners must ensure the boiler is:

THE CARE AND FEEDING OF YOUR RV IIl

Cooling Capacity CFM in. w.c. (125 Pa)

Electronically Controlled Clutchless or Variable Drive Compressors

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Heating Basics Gas Valve Systems

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Installation Questions

SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN AGREEMENT. A. Silver Plan

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Commercial Gas Furnace Upflow

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

37E73A-903 & 906 INTELLI-VENT

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

A/C-HEATER SYSTEM - AUTOMATIC

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

Air conditioning, electrical testing

Cooling Capacity CFM in. w.c. (125 Pa)

Trouble Shooting. Pump

E-gas Instant Gas Water Heaters

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

Rinnai Tankless. Water Heater. Troubleshooting Manual

Glossary of Heating, Ventilation and Air Conditioning Terms

SERVICE DIAGNOSIS Modine heating & ventilating equipment

Residential Gas and Electric Water Heaters


Loop Calibration and Maintenance

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Boiler and Burner Cleaning and Servicing Specifications

Service Manual Models:

NAVIEN AMERICA INC FITCH AVENUE

Thermo Top - Troubleshooting Tree

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Service Handbook Commercial / Residential gas water heater

Commercial Gas Water Heater

Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU

E2 Series Electric Furnaces

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Boiler Preparation, Start-Up and Shutdown

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%


Service Manual Models: 502, 752, 1002, 1302,

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

HERZ-Thermal Actuators

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

i ChatterBox! Motorcycle Security

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

PRODUCT DESIGN. 5. Furnace awaits call from thermostat.

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Fault Finder. A Service Engineers. for Warm Air Heating. Publication No. ZZ April 2015

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Use your troubleshooting superpowers for good Application Note

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Air Conditioning System

Maintaining Conventional Residential Oil-Fired Heating Systems

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

CARING FOR YOUR WATER HEATER

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Transcription:

Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating systems and how to troubleshoot these systems using thermos, digital multis (s), s, pressure/ vacuum modules and other accessories. Heat pumps and forced air electric heat furnaces are discussed in other application notes available from Fluke. Heating systems principles Forced-air heat is generated at a central furnace and is then distributed and delivered to the conditioned space via a duct system. A properly designed heating system will generate quiet, filtered, and comfortable air into the conditioned zone. Modern systems have been recently designed that will also filter the air electronically, modulate airflow as zone temperatures change, and bring in fresh outside air based on occupied time. There are three types of fossil fuel heating systems predominantly available on the market today. These include natural gas, liquefied petroleum (LP) and fuel oil forced-air furnaces. Fossil fuel forced-air heating Forced-air fossil fuel furnaces are factory manufactured, packaged heating units that include: A combustion chamber designed for gas or oil A heat exchanger A flue gas exhaust chamber A forced air circulating fan and, A controller section. Newer units often include a secondary heat exchanger to increase efficiency and an auxiliary fan for combustion gases. Since the newer units substantially cool the combustion gases, removing water vapor from the combustion gases, they often are called condensing high-efficiency furnaces. Additionally, they will have plastic flue gas piping instead of older more traditional metal flue pipe since the gas temperatures are much lower than less efficient older units. Older standard gas furnaces were 65 % to 78 % efficient, with microamps capability testing the flame rectification circuit. while newer high efficiency furnaces are 78 % to 85 % efficient when used with induced draft fans. Modern condensing furnaces, however, are 90-95 % efficient. Modern fossil fuel furnaces also come equipped with electronic controls for ignition, fan speed control, electronic thermostats, and safety controls. The typical operating pressure of the natural gas furnaces at the burner is 3.5 inches of water column. Natural gas is predominantly used as the preferred fuel in larger cities and communities where main gas lines are available. Fuel oil and Liquid Petroleum (LP) heating furnaces are more popular in rural communities. F r o m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e. c o m / l i b r a r y

T1 TYPE K CANCEL MIN MAX C FK HOLD T1 T1- SETUP 52 THERMOMETER HOLD ENTER F Oil heat Air temperature difference Check the temperature difference across the furnace. (Similar to the gas furnace TD check.) Check list Primary line voltage Secondary voltage Flue gas Thermostat volts Heated air Oil pump volts Carbon monoxide Use a carbon monoxide to check for CO leaks around the heat exchanger, flue and other points within a building. Combustion pump & blower Combustion chamber Ignition Step up transformer Primary voltage Cad cell test Resistance is inversely proportional to light intensity. Bright light equals Ø ohms. Dark equals 100,000 ohms. Resistance must remain below 1600 ohms during burner operation, 200-800 ohms is typical. Oil tank (above ground) Fuses Fan amps Fan run capacitor Air temperature difference Flame detection CO level Pressure differential / IR thermo Clamp / Digital thermo / Carbon monoxide Pressure Transducer Cold air Fan amps Net BTU s = gross BTU s x efficiency rating Oil filter Figure 1. Key measurement points on an oil system. Fuel oil (diesel) furnaces are similar to gas furnaces except that the fuel must be pumped and atomized within the furnace combustion chamber, since it is provided to the customer in the liquid state. Plus, the atomized oil must be ignited with high voltage electrodes. The components within LP heating furnaces are almost identical to traditional natural gas furnaces, except the operating pressure of the gas at the burner is typically 9 to 11 inches of water column. The temperature of the zone is determined by controlling the combustion process as needed in order to transition heat into the conditioned space. This often requires a pre-purge, purge, ignition sequence, flame proof and verification, combustion cycle, and post-purge upon completion. Troubleshooting fossil fuel forced-air heating furnaces When troubleshooting the fossil fuel forced-air furnace, it is important to break the unit down into three basic components: The thermostat control system The ignition control sequence The fan control system Testing the thermostat control system The thermostat control system on any furnace follows a basic design. It is comprised of two wires; a red wire for 24 volt ac power, and a white wire for the main heat control signal back to the furnace. When cooling is controlled from the same thermostat, then a green wire for fan control and a yellow wire for condensing unit control will also be present. Heating and cooling switching is based on temperature changes. Independent fan operation between heating or cooling cycles is controlled by a manual switch. Some equipment has more than one stage of heating or cooling. In these cases, there will be a W1 output for first stage heat, a W2 output for second stage heat, a Y1 output for first stage cooling, a Y2 output for second stage cooling. Second stage outputs may alternately be controlled by electronic timers rather than a temperature sensitive switch. When troubleshooting the thermostat, it is important to first verify that 24 volt ac power is available at the transformer secondary and at the thermostat. Checking current with a. Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques

Once this is verified, then you should use a digital multi () or an HVAC to check for voltage at the white wire coming from the thermostat. If power is available at the transformer, but not at the outlet of the thermostat, then the problem is with the thermostat. If the power signal is available at the white wire at the outlet of the thermostat, but is not powering up the heating primary control, check for an open safety switch or loose connection at the primary control. The primary control may be a gas valve on a standing pilot furnace, an ignition control on a hot surface or spark ignition gas furnace, a sequencer on an electric furnace, or an oil burner primary control. Testing the fan control system Like the thermostat, the fan control system, which automatically turns on the fan, is simple and straightforward. Traditional furnace fan controls used a temperature reactant bimetal probe in the plenum to control a fan switch. These controls had a Fan-ON and a Fan-OFF temperature setting. Some even had a self contained heater to act as a Fan-ON timer by adding heat to the bimetal probe. This heater paralleled the burner control signal to start the timing. Most modern furnaces have migrated to electronic fan timers that start and stop the fan at pre-set or adjustable timings after the combustion process has begun or ended. Both methods of fan control rely on establishing and maintaining the combustion process before they will start the fan. To troubleshoot the fan plenum control system, first verify that the plenum combustion chamber is getting hot. If it is not hot, check the main gas valve and combustion controls. If it is hot and the fan is not running, check the condition of the fan motor. It is possible it has failed due to seized bearings. While the power is off, check to see if the fan spins easily. Check the combustion fan control to make sure it isn t stuck open and preventing the fan from running. This can be done with a or multifunction clamp. The combustion fan is called a Combustion Air Blower on a 90 percent (Category IV) furnace and is called a Combustion Air Inducer on an 80 percent (Category I) furnace. All furnaces that use a combustion fan must establish that a minimum air volume exists before an ignition sequence is allowed. This is normally accomplished with a pressure differential switch. Use a volt to determine if the pressure switch is closing after the combustion fan reaches full speed. If the switch does not close, use a pressure transducer to measure the pressure differential. If the pressure differential is greater than the listed make pressure, then the switch is faulty. If the pressure differential is less than the Make pressure, then there is a problem within the furnace or in the vent system. If the circulating fan is running and you want to determine if it is set at the proper speed, then you need to check the temperature difference across the combustion heat exchanger. This requires measuring the return air temperature and the discharge air temperature. These temperatures can be checked by using a digital recording thermo to log the temperatures. The normal temperature difference is about 40 F to 70 F. Note, this will vary depending upon the equipment manufacturer s design of the heat exchanger surface, so be sure to look at the manufacturer s specifications within the unit for acceptable temperature difference variations. Testing voltage with a multi-function. Testing the flame verification control system Checking the flame verification control system is required as part of the troubleshooting process when a flame will not stay lit on a gas or oil furnace. Fuel oil heating furnaces use several types of flame verification systems. Older gas furnaces use a thermocouple with a millivolt signal to verify flame presence. Newer, more efficient gas systems utilize various electronic flame verification systems. Oil furnaces use a cad cell with a resistance output to the controllers. Some manufacturers have also tried using a temperature actuated switch mechanism. This article will only address the most popular flame verification systems including the thermocouple, flame rod system, and cad cell system. 3 Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques

To test the unloaded condition of the thermocouple you simply measure the output signal of the thermocouple with a or. This is accomplished by unscrewing the thermocouple from the gas valve and attaching the leads from your or to the positive and negative polarities of the thermocouple. Normal unloaded output signals of the thermocouple when heat is applied to the tip is 20 millivolts to 30 millivolts. The thermocouple should be tested under load. For this test, a thermocouple adapter must be placed in series between the gas valve and the thermocouple. This allows the loaded millivolts to be tested. A good thermocouple in a good flame location should be at least 8-12 millivolts. The drop out point of the safety solenoid in the gas valve is usually about 4 millivolts. Testing the flame rod. (See Figures 2 and 3.) Most of today s light commercial and residential gas burner controls utilize a flame rod to confirm the presence of the flame. Here s how it works: The ignition control sends out a voltage to the flame rod. The flame itself serves as a partial diode rectifier between the flame rod and the ground. Without a flame, the circuit is open and there is no current. However, the presence of a flame will allow a few microamps of dc current to flow. The acceptable microamp reading varies from one manufacturer to another. Expected microamp values vary widely between controls. The drop out microamps may be as low as 0.16 microamps, or upwards of 18 microamps and higher. The test procedure itself is simple. 1. Shut off the furnace and locate the single wire between the controller and the flame rod. Typically, the wire is terminated at the control panel or the flame rod with standard spade connectors. Furnace Burner Flame Rod Spade Clip gripped by AC70 Alligator Clips on TL75 Test Leads 2. Break the spade connection and place the test leads from a or that measures microamps in series into the circuit. Having alligator clips for the test leads will make the connection much easier. 3. Turn on the and set it in the dc microamp (µa) mode. Restore power to the furnace (follow furnace manufacturer s instructions for safe operation) and set the furnace to call for heat. 4. Once the burner or pilot ignites, check your reading. Refer to the furnace troubleshooting instructions to determine how to proceed with this result. Typically, a low or zero microamp reading may indicate several potential problems including: a. The flame sensor is not close enough to the flame. b. Carbon build-up on the rod is limiting current flow (clean flame rod with steel wool). c. The flame rod is shorted to ground. d. Continuity is not present between the control module and the flame rod (use a or with continuity function to check). e. The control module is bad and needs to be replaced. Verify using the equipment manufacturer s manual. Gas Burner Controller Figure 2. With this setup, either an HVAC or an HVAC can be used. Checking the 24 V ac supply voltage. 4 Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques

T1 TYPE K CANCEL MIN MAX SETUP 52 THERMOMETER HOLD C FK T1 T1- HOLD ENTER F Gas heat Check list Loose electrical connections/ overloaded circuits IR thermo Carbon monoxide Use a carbon monoxide to check for CO leaks around the heat exchanger, flue and other points within a building. Control voltage Use a voltage detector or to test for energized 24 V ac contacts. Use an infrared (IR) thermo to check for loose connections or overloaded circuits. Belts and bearings Use an infrared thermo to check belts for alignment and bearings for excessive friction. 561 HVACPro IR THERMOMETER Flue gas Inducer fan Heated air Control module Primary voltage Flame rod µa test Verify proper operation of the flame rectification circuit with a or digital multi in the µa mode. Compare measured value against flame control module specifications. Typical values vary widely and can be as low as 0.16 to 18.0 µa or more. If the µa reading is below specification, the flame rod may need to be repositioned, cleaned, or replaced. Air temperature difference Check the temperature difference across the heat exchanger with a digital thermo, with the burner working. Expect a 40-75 F temperature difference (TD). If the TD is low, then the fan is running too fast. If the TD is high, then the fan is running too slow or there is restricted air flow. Thermostat verification Primary voltage Secondary voltage Thermostat volts Air temperature difference Fuses Fan relay volts Fan amps Fan run capacitor Flame detection (ua) CO level Thermo Digital thermo Clamp / / Carbon monoxide Cold air Figure 3. Key measurements on a gas system. Testing the cad cell. Most of today s light commercial and residential oil burner controls utilize a cad cell to confirm the presence of the flame. These systems work in the following manner: 1. On a call for heat, the primary control starts the pump motor and energizes a high voltage transformer to create an ignition spark. 2. The igniters start the combustion process. The flame light serves as the energy source which powers the cad cell. 3. As light increases, the resistance goes down. As the resistance goes down, the controller verifies the flame condition and continues to allow the oil pump to operate. If the oil pump fails or oil pressure is lost, the cad cell sends a much higher resistance to the control and the oil pump shuts off on a manual reset. Without a flame, the circuit opens up and there is no oil pump pressure delivered to the combustion chamber. To test the cad cell shut off the furnace and locate the two wires which run from the cad cell to the controller. Typically, the wires are terminated at the primary control F F terminals. Connect an ohm to the cad cell leads. After flame is established, the F F terminals must be jumpered to maintain ignition. This allows for an unhurried reading of the cad cell resistance. 1. Start the oil burner. 2. After ignition, jumper the F F terminals on the primary control. 3. Read the resistance across the cad cell. The resistance must be well below the drop-out resistance of 1600 ohms. This will typically be between 200-800 ohms. Dirt or soot on the face of the cad cell will block light from the burner and cause a higher than expected resistance. A higher than expected resistance will also occur if the cad cell is misaligned so it cannot properly see the flame. With the burner off, make sure the cad cell is clean and properly aligned so it can see the flame. Use a drop light to check the cad cell. With the light on, the resistance should drop toward zero. With the light off (and the ambient area dark), the resistance should increase toward 100,000 ohms. Make sure there is a good connection between the cad cell pins and the cad cell socket. If the burner is located in an area of bright ambient light, the cad cell may be getting a false light reading of 800 ohms or less. The oil primary control will not allow the burner to start if light is sensed when the burner should be off. Having alligator clips for the test leads will make the connection much easier. Turn on the and set the in the ohms mode. Read the resistance with the cad cell exposed to the light within the mechanical space. If the light is not bright enough, shine your flashlight into the surface of the cad cell. As the light is increased, the resistance goes down toward zero ohms. 5 Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques

Next cover the cad cell with a piece of black electrical tape. The resistance should go up to approximately 100,000 ohms. If the cad cell does not respond to a change in light intensity, it has gone bad and needs to be replaced. If the resistance does vary between zero and 100,000 ohms as light is added or removed, it is probably operating properly, and you need to look for other problems within the furnace control circuit. Test points on fossil fuel furnaces I. Low voltage Thermostat, continuity and low amps at heat anticipator (1 to.2) Gas valve 24 volts ac Safeties-limits, air pressure, temperature Flame proof thermocouple mv, flame rod microamps II. High voltage on oil furnaces 120 V ac, 5000 V dc to 12,000 V dc ignition III. Gas supply Natural gas: 7 inches w.c. supply pressure and 3.5 inches w.c. manifold pressure (typical) LP gas: 11 inches w.c. supply pressure and 8-10 inches w.c. manifold pressure (typical) IV. Combustion gases CO2 or O2 are a measure of excess air CO is a measure of the quality of combustion V. Temperature CO2 (or O2) along with vent temperature is a measure of combustion efficiency Standard older furnaces 450 F Mid efficiency furnaces 350 F High efficient furnaces 90 % and up, very cool, uses PVC piping Temperature difference across heat exchanger indication of proper air flow will be between 40 F to 70 F. Note: This will vary depending upon the equipment manufacturer s design of the heat exchanger surface. Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 6/2006 2434064 A-EN-N Rev B 6 Fluke Corporation Fossil fuel heating equipment-principles and troubleshooting techniques