Air Conditioning. Light Commercial, Commercial and Industrial

Similar documents
Cooling kw Heating kw

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

ECOCIAT. Domestic hot water heat recovery unit

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

york air-conditioning products Residential & VRF News 2015

CRAC Precision climate control units for data centres

Cool Design for Homes and Offices

AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION

LG Electronics AE Company, Commercial Air Conditioning

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Technical data. Danfoss DHP-A

State of the Art Energy Efficient Data Centre Air Conditioning

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

FULL DC INVERTER SYSTEMS

- White Paper - Data Centre Cooling. Best Practice

HVAC Systems: Overview

HP switch LP switch Discharge thermo Comp. Surface thermo

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

RPV - RP - RA air handling units

Combi Unit Genius. The energy efficient Building Service Centre

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

TWE+TTA TWE+TWA T.R.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Condensing unit type EPSILON-ECHOS LE Technical information manual

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Appendix - Controllers 179

YCAA-B AIR COOLED LIQUID CHILLER

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

MAC-120HE-01 Air-Cooled Chiller

Air-cooled Chillers with High Speed Centrifugal Compressors

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

Eurovent Certification

Direct Fresh Air Free Cooling of Data Centres

Test Report issued under the responsibility of:

Chilled Water Precision Air Conditioner For Critical Application

HEAVY DUTY STORAGE GAS

SustainE(Sustainable Energy)

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

FTQ. Daikin Inverter Ducted Heat Pump

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

UDSA - UDSBD unit heater

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

ARMSTRONG AIR HEAT PUMPS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Tim Sisson - Trane HVAC OVERVIEW

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Daikin Altherma hybrid heat pump. The natural combination

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Commercial Hot Water. Make a difference...

Split System Heat Pump Product Data

Local Dealer:

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Air-water systems for efficient air conditioning

We have been working in an ideal climate for thirty years.

Inverter Air Conditioning for Light Commercial Use

Topvex SX/C, Topvex TX/C. Air Handling Unit

marine/bespoke split applications

Samurai range. Screw Type Water Chillers Cooling Only & Heat Pump Versions

SECTION HEAT PUMPS

Under sill units. Type FSL-B-ZAS

Air cooled screw chillers

Split System Cooling Product Data

TurboChill & TurboChill FreeCool

Product Data. Split System Cooling F-EN. March 2015

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

COMMISSIONING OF HVAC SYSTEMS

Rotary screw compressors kw 5,5 7, , bar MODULO

News in Data Center Cooling

Natural geothermal energy.

Company Presentation

Elements of Energy Efficiency in Data Centre Cooling Architecture

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Screw Compressors ESM Fixed Speed & VS Variable Speed

catalog Single Package Vertical Air Conditioners and Heat Pumps

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Air Conditioners Technical Data

Versati Air to Water Heat Pump

type UTA Technical information manual

Mechanical Rooftop Custom Capabilities

MAROON kw. General information. Unique selling points

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Low Profile Unit Cooler

Transcription:

Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Conditioning Light Commercial, Commercial and Industrial

Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is a question of cooperation, quality, deliveries or documentation. This catalogue is of course a part of this work. With this catalogue, which features products of air conditioning, we want to give you as a customer a general overview of what Systemair can offer within this field. More detailed information are available in our Online catalogue at www.systemair.com and as downloadable software. Systemair s range of fans, air distribution products and accessories also appears in our printed main catalogue. Our product development leads the field - latest technologies in unitdesign, fans, motors, heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power consumption. Systemair has grown each year since the start and we aim to continue with this trend. Systemair strives to be a reliable supplier of quality products. We help our customers to focus on their own business. Reliable deliveries give the customer greater possibilities to quickly complete a job, and move on to the next project. At Systemair we call this Trust. Systemair 2015. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com

Content 1 Content Systemair 2 Product Range 6 Application 8 Air Cooled Chiller & Heat Pumps 10 Water Cooled Chiller, Heat Pumps and Condensing Unit 131 Free-Cooling 155 Condensing Unit 161 Residential Heat Pump 190 Water Terminals 200 Water Source Heat Pump 228 Roof Top 240 Close control 246 Direct Expansion 252 Hydrokit HPT 262

Systemair 2 Systemair worldwide Skinnskatteberg, Sweden: Systemair AB, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. Also located here is the company s most advanced test installation for measuring technical data. Klockgården, Sweden: Systemair s small air handling units are manufactured at Klockgården in Skinnskatteberg. Frico s central warehouse of approximately 8000 m 2 is also located here. Windischbuch, Germany: Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center. Langenfeld, Germany: Production of air curtains. Hässleholm, Sweden: VEAB is the leading European manufacturer of electric duct heaters. Production of heating and cooling coils, electric and water based. Ukmerge, Lithuania: Production of smaller air handling units with energy recovery systems. Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified. Hasselager, Denmark: Production of modular air handling units. Dal Eidsvoll, Norway: Production of air handling units.

Systemair 3 Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Save energy, lower running cost! Our label Green Ventilation features products with a high energy saving potential. All products labelled with Green Ventilation combine energy economy with energy efficiency. Kansas City, USA Bouctouche, Canada Dal, Eidsvoll, Norway Skinnskatteberg, Sweden Hasselager, Denmark Hässleholm, Sweden Ukmerge, Lithuania Waalwijk, Netherlands Langenfeld, Germany Windischbuch, Germany Tillières-sur-Avre, France Bratislava, Slovakia Maribor, Slovenia Barlassina, Italy Madrid, Spain Istanbul, Turkey New Delhi, India Hyderabad, India Kuala Lumpur, Malaysia Bratislava, Slovakia: The factory in Bratislava manufactures air distribution products and EN certified fire and smoke dampers. Kuala Lumpur, Malaysia: Production and marketing of products for Tunnel and garage ventilation. Madrid, Spain: Production of air handling units for the southern European market. Hyderabad, India: Production of air distribution products. New Delhi, India: The factories in New Delhi and Noida manufacture grilles and diffusers. Barlassina, Italy: Our factory in Italy, Systemair, develops and manufactures a wide range of chiller and heat pump in A class from 20 to 1.700kW. Bouctouche, Canada: Our main North American production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche. Kansas City, USA: Production of fans for the US market. Istanbul, Turkey: Systemair-HSK is Turkey s leading manufacturer of air handling units. Waalwijk, Netherlands: Holland Heating is Netherlands leading manufacturer of air handling units. Tillières-sur-Avre, France: Our factory in France, Systemair, develops and manufactures: Roof top, water source heat pump, hight temperature heat pump, water terminals.

4 Systemair worldwide Systemair (France) The Factory of Tillières-sur-Avre The company Systemair AC, French factory of Systemair group, Founded in 1947 by Paul Vallet, is one of the globally leading manufactures and distributors air conditioning systems. Over 60 years of experience in the design, development and production of residential, commercial and industrial applications make Systemair an indispensable actor on the european market. References are numerous in France and internationally and concern all sectors of activity including many hospitals (surgery rooms, white rooms...) industrial sites, energy-efficient office buildings, hotels, and also under naval board. Our sales department will be able to illustrate our references according to your requests. The factory benefit from ISO certifications 9001 freed delivered by the most recognized certification bodies. Besides, Systemair AC participates in the certification programme Eurovent insuring by independent laboratories the check of the technical specifications according to the international standards. Production The Factory in France, Extends over a total area of 36.000 sqm with 150 employees. The number of employees, including the organization of sales is more than 200 people. Range The factory develops and manufactures a wide range of air conditionning produts: Chillers & Heat Pumps Water Terminals Residential heat pump Water Source Heat Pump Close control Direct expansion. Brand Products of French factory, are sold under systemair brand.

Systemair (Italy) Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Systemair 5 Save energy, lower running Systemair cost! Our label Green Ventilation features products with a high energy saving potential. All products labelled with Green Ventilation combine energy economy with energy efficiency. The factory of Barlassina The company Systemair, Italian factory of Systemair Group, is important in equipment for HVAC s market from 20 to 1.700 kw suitable for a wide range of applications of air conditioning and industrial processes. Systemair has 70 years experience in the industrial production, of which 50 years in HVAC business. Systemair Italy is equipped with high tech equipment and has one of the most modern research centers in Europe for the devlopment and testing the of chillers and heat pumps. The range of product, that is Eurovent certified, consist of Air and Water cooled chillers and heat pumps as well as condensing and conderseless unit. Range The factory, develops and manufactures a wide range of air conditioning produts: Chillers & Heat Pumps Condensing Unit Close control. Brand Products of our Italian factory, are sold under systemair brand. Production The factory in Italy extend over a total area of 33.400 sqm and a manufacture area over of 19.400 sqm with around 200 employees.

6 Product range Product range Systemair has an extensive range of ventilation products: fans including smoke extractor, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc. Fans Systemair has the wider range of fans for use in different applications. Our range includes any type of fans, from circular ducts hystorical product boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. All products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. All our fans are designed to meet the strict requirements, easy to use, high quality and durability. Duct fans Duct fans for circular duct installation. Centrifugal fans Centrifugal supply single fans. Rectangular duct fans Duct fans with rectangular connection. Square duct fans For different applications, there are models for ambient with high temperature. Axial fans Axial fans for duct or wall application. Roof fans Roof fans with circular or square connection. Explosion proof fans Explosion proof fans in duct, roof or wall design. Jet Axial Fans Jet Axial Fans for car park, tunnels and air overpression. High temperature fans Systemair provides high fire resistance fans till 600 C/2 hours.

Product range 7 Air handling units Systemair produces a wide range of air handling units for several applications, from small office to large industrial building. All range is been developped to satisfy strict needs of low energy consumption. Fire and smoke dampers Smoke extract fans High efficient fans to extract the combustion smoke. Fire & smoke dampers Dampers that reduce the spread of smoke and fire. Residential ventilation Complete energy-efficient air handling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics. Residential units For homes with living areas of 60-320 m 2. Cooker hoods Ideal for capturing odours even at low airflows. Air distribution products The range also includes a wide selection of air distribution products and accessories. Supply, extract & transfer devices For mounting in ceilings or walls. Nozzle diffusers Optimum flexibility and comfort in air distribution for rooms.

Applications Schools In buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the required flexibility. Offices In buildings for tertiary application, the air conditioning and the ventilation are necessary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines. Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices.

Commercial buildings Normally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant monitoring of concentration of pollutants (VOC and CO 2 ). Systemair ACʼs products can easily meet the plantʼs requirement. Industry Industrial plants generate a large amount of heat that must be dissipated in the appropriate way. Systemair AC offers a wide range of products (chillers from 20 kw to 1.700 kw) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10 C). Hotels In the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact, required by this type of installations.

Air Cooled Chiller & Heat Pump Mini SysAqua DCI 5-16 5-14.5 kw 5.5-16 kw 410A Rotary Inverter Plate INVERTER SysAqua 45 to 125 L-H 46-122 kw 50-120 kw 410A Scroll Plate SyScroll 20-30 Air EVO HP 20-36 kw 20-34 kw 410A Scroll Inverter Plate SyScroll 85-135 Air CO-HP 84-132 kw 85-133 kw 410A Scroll Plate SyScroll 20-35 Air CO-HP 21-34 kw 21-35 kw 410A Scroll Plate AQVL/AQVH 85-140 85-137 kw 87-144 kw 410A Scroll Plate SysAqua 25-40 L-H 25-37 kw 27-40 kw 410A Scroll Plate SyScroll 140-360 Air EVO CO-HP 144-361 kw 145-361 kw 410A Scroll Plate SyScroll 40-75 Air CO-HP 41-77 kw 39-76 kw 410A Scroll Plate SyScroll 240-660 Air CO-HP 238-654 kw 256-679 kw 410A Scroll Plate INVERTER

VLS/VLH 604-1204 153-307 kw 170-337 kw 410A Scroll Plate AQWH 1404-2406 359-602 kw 420-702 kw 410A Scroll Plate SyScrew 360-1300 Air CO 365-1.316 kw 134a Screw Shell & Tube SyScrew 370-1100 Air EVO CO 364-1.118 kw 134a Screw Shell & Tube SLS HE 5204-8404 1.142-1.687 kw 134a Screw S&T evaporator

12 Air cooled Chiller & Heat Pump Selection guide Air Cooled Chiller Product Range Capacity EER Flow rate Acoustic Power SyScroll 20-35 Air CO SysAqua L SyScroll 40-75 Air CO SysAqua L SyScroll 85-135 Air CO AQVL 85-140 Size (LxHxP) SyScroll 20 Air CO 20,8 kw 3,12 0,97 l/s 73 1.477 x 1.615 x 539 SyScroll 25 Air CO 24,4 kw 3,29 1,14 l/s 74 1.477 x 1.615 x 539 SyScroll 30 Air CO 28,2 kw 3,14 1,32 l/s 74 1.477 x 1.615 x 539 SyScroll 35 Air CO 33,7 kw 2,93 1,59 l/s 75 1.477 x 1.615 x 539 SysAqua 25 L 26,6 kw 3,09 1,19 l/s 75 1.000 x 1.983 x 1.000 SysAqua 30 L 28,3 kw 3,03 1,27 l/s 75 1.000 x 1.983 x 1.000 SysAqua 35 L 37,6 kw 2,97 1,69 l/s 76 1.000 x 1.983 x 1.000 SysAqua 40 L 39,3 kw 2,88 1,75 l/s 76 1.000 x 1.983 x 1.000 SyScroll 40 Air CO SyScroll 45 Air CO SyScroll 50 Air CO SyScroll 60 Air CO SyScroll 65 Air CO SyScroll 75 Air CO 40,8 kw 2,91 1,9 l/s 80 44,8 kw 2,77 2,1 l/s 81 51,9 kw 2,79 2,4 l/s 81 60,9 kw 2,97 2,8 l/s 85 68,9 kw 2,93 3,2 l/s 86 76,7 kw 2,75 3,6 l/s 86 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 SysAqua 45 L 49,1 kw 2,91 2,22 l/s 79 2.180 x 1.986 x 1.160 SysAqua 55 L 56 kw 2,85 2,52 l/s 79 2.180 x 1.986 x 1.160 SysAqua 65 L 69,1 kw 3,13 3,13 l/s 79 2.180 x 1.986 x 1.160 SysAqua 75 L 75,1 kw 3,10 3,41 l/s 79 2.180 x 1.986 x 1.160 SysAqua 90 L 96,0 kw 2,79 4,36 l/s 82 2.180 x 1.986 x 1.160 SysAqua 105 L 111,5 kw 2,93 5,05 l/s 82 2.180 x 1.986 x 1.160 SysAqua 125 L 2,76 5,80 l/s 82 2.180 x 1.986 x 1.160 SyScroll 85 Air CO 84,2 kw 3,09 4,02 l/s 84 3.000 x 2.250 x 1.100 SyScroll 95 Air CO 93,2 kw 2,96 4,44 l/s 84 3.000 x 2.250 x 1.100 SyScroll 105 Air CO 104,6 kw 2,77 5 l/s 88 3.000 x 2.250 x 1.100 SyScroll 120 Air CO 118,6 kw 2,82 5,6 l/s 88 3.500 x 2.250 x 1.100 SyScroll 135 Air CO 128 kw 132,1 kw 2,78 6,3 l/s 88 AQVL 85 83,3 kw 3,08 3,9 l/s 85 AQVL 95 93,3 3,01 4,4 l/s 85 AQVL 105 102,6 kw 3,05 4,9 l/s 85 AQVL 115 110,5 kw 3,02 5,2 l/s 85 AQVL 125 121,6 kw 2,97 5,8 l/s 89 AQVL 140 136,5 kw 2,96 6,5 l/s 89 3.500 x 2.250 x 1.100 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 3.155 x 2.185 x 1.095 3.155 x 2.185 x 1.095

Air cooled Chiller & Heat Pump 13 Air Cooled Chiller & Heat Pump Product Range Capacity EER Flow rate Acoustic Power SyScroll 140-360 Air Evo CO VLS 604-1204 SyScroll 240-660 Air CO SyScroll 140 Air Evo CO SyScroll 170 Air Evo CO SyScroll 200 Air Evo CO SyScroll 230 Air Evo CO SyScroll 260 Air Evo CO SyScroll 280 Air Evo CO SyScroll 300 Air Evo CO SyScroll 330 Air Evo CO SyScroll 360 Air Evo CO 144 kw 3,22 6,9 l/s 90 168,6 kw 3,11 8,0 l/s 90 196,4 kw 3,17 9,4 l/s 92 229,9 kw 3,11 11,0 l/s 92 262,6 kw 3,15 12,5 l/s 93 283,5 kw 3,14 13,5 l/s 93 309,3 kw 3,14 14,8 l/s 94 330,3 kw 3,18 15,8 l/s 95 360,7 kw 3,11 17,2 l/s 95 VLS 604 153,4 kw 2,75 7,3 l/s 93 VLS 704 176,2 kw 2,67 8,4 l/s 93 VLS 804 198,1 kw 2,74 9,4 l/s 93 VLS 904 228,4 kw 2,75 10,9 l/s 94 VLS 1004 250,3 kw 2,88 11,9 l/s 94 VLS 1104 279,1 kw 2,79 13,3 l/s 95 VLS1204 306,9 kw 2,67 14,7 l/s 95 Size (LxHxP) 4.000 x 2.600 x 1.100 4.000 x 2.600 x 1.100 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 3.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 SyScroll 240 Air CO 238,1 kw 2,84 11,4 l/s 93 3.500 x 2.600 x 2.150 SyScroll 270 Air CO 267,4 kw 2,7 12,8 l/s 93 3.500 x 2.600 x 2.150 SyScroll 290 Air CO 287,4 kw 2,78 13,8 l/s 94 3.500 x 2.600 x 2.150 SyScroll 320 Air CO 316,1 kw 2,83 15,13 l/s 94 3.500 x 2.600 x 2.150 SyScroll 360 Air CO 362 kw 2,82 17,3 l/s 94 4.550 x 2.600 x 2.150 SyScroll 420 Air CO 414,2 kw 2,78 19,8 l/s 95 4.550 x 2.600 x 2.150 SyScroll 470 Air CO 469,6 kw 2,92 22,5 l/s 95 5.600 x 2.600 x 2.150 SyScroll 540 Air CO SyScroll 590 Air CO SyScroll 660 Air CO 533,7 kw 588,9 kw 654,2 kw 2,9 25,6 l/s 96 2,97 28,2 l/s 96 2,95 31,4 l/s 97 5.600 x 2.600 x 2.150 6.650 x 2.600 x 2.150 6.650 x 2.600 x 2.150

14 Air cooled Chiller & Heat Pump Selection guide Air Cooled Chiller Product Range Capacity EER Flow rate Acoustic Power SyScrew 370-1100 Air EVO CO SyScrew 360-1300 Air CO Size (LxHxP) SyScrew 370 Air EVO CO 364,1 kw 3,23 17,3 l/s 97 4.600 x 2.550 x 2.200 SyScrew 400 Air EVO CO 414,5 kw 3,18 19,8 l/s 98 5.700 x 2.550 x 2.200 SyScrew 450 Air EVO CO 445,5 kw 3,11 21,2 l/s 98 5.700 x 2.550 x 2.200 SyScrew 500 Air EVO CO 502,9 kw 3,15 24,0 l/s 98 5.700 x 2.550 x 2.200 SyScrew 570 Air EVO CO 562,1 kw 3,18 26,8 l/s 99 6.700 x 2.550 x 2.200 SyScrew 650 Air EVO CO 625,5 kw 3,16 29,8 l/s 99 6.700 x 2.550 x 2.200 SyScrew 700 Air EVO CO 712,9 kw 3,19 34,0 l/s 99 7.800 x 2.550 x 2.200 SyScrew 750 Air EVO CO 749,2 kw 3,16 35,7 l/s 100 7.800 x 2.550 x 2.200 SyScrew 850 Air EVO CO 839 kw 3,21 40,0 l/s 100 8.800 x 2.550 x 2.200 SyScrew 950 Air EVO CO 961,8 kw 3,33 45,9 l/s 101 9.900 x 2.550 x 2.200 SyScrew 1000 Air EVO CO 1.019 kw 3,26 48,6 l/s 101,00 10.900 x 2.550 x 2.200 SyScrew 1100 Air EVO CO 1.117,90 kw 3,29 53,4 l/s 102,00 12.000 x 2.550 x 2.200 SyScrew 360 Air CO 365 kw 2,71 17,4 l/s 96 4.600 x 2.550 x 2.200 SyScrew 410 Air CO 413 kw 2,73 19,7 l/s 97 4.600 x 2.550 x 2.200 SyScrew 450 Air CO 445 kw 2,65 21, l/s 97 4.600 x 2.550 x 2.200 SyScrew 480 Air CO 480 kw 2,72 22,9 l/s 97 4.600 x 2.550 x 2.200 SyScrew 500 Air CO 505 kw 2,74 24,1 l/s 97 4.600 x 2.550 x 2.200 SyScrew 540 Air CO 540 kw 2,72 25,8 l/s 98 5.700 x 2.550 x 2.200 SyScrew 580 Air CO 575 kw 2,7 27,4 l/s 98 6.700 x 2.550 x 2.200 SyScrew 650 Air CO 652 kw 2,75 31,1 l/s 99 6.700 x 2.550 x 2.200 SyScrew 720 Air CO 713 kw 2,81 34,1 l/s 99 6.700 x 2.550 x 2.200 SyScrew 800 Air CO 794 kw 2,88 37,9 l/s 99 6.700 x 2.550 x 2.200 SyScrew 850 Air CO 851 kw 2,85 40,6 l/s 100 8.800 x 2.550 x 2.200 SyScrew 910 Air CO 909 kw 2,84 43,4 l/s 100 8.800 x 2.550 x 2.200 SyScrew 970 Air CO 971 kw 2,85 46,3 l/s 100 8.800 x 2.550 x 2.200 SyScrew 1000 Air CO 1.008 kw 3 48,1 l/s 100 8.800 x 2.550 x 2.200 SyScrew 1070 Air CO 1.071 kw 2,88 51,1 l/s 100 9.900 x 2.550 x 2.200 SyScrew 1130 Air CO 1.132 kw 2,89 54,1 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1170 Air CO 1.172 kw 2,85 55,9 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1200 Air CO 1.218 kw 2,82 58,2 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1300 Air CO 1.316 kw 2,82 62,8 l/s 102 12.000 x 2.550 x 2.200

Air cooled Chiller & Heat Pump 15 Air Cooled Chiller & Heat Pump Product Range Capacity EER Flow rate Acoustic Power SLS 5204-8404 HE SLS 5204 HE 1.142 kw 3,50 54,5 l/s 102 SLS 5604 HE 1.208 kw 3,50 57,7 l/s 102 SLS 6004 HE 1.292,80 kw 3,40 61,7 l/s 103 SLS 6404 HE 1.406,40 kw 3,40 67,2 l/s 103 SLS 6804 HE 1.482,20 kw 3,20 70,8 l/s 103 SLS 7204 HE 1.557,90 kw 3,00 74,4 l/s 103 SLS 7804 HE 1.637,20 kw 3,00 78,2 l/s 103 SLS 8404 HE 1.686,90 kw 2,90 80,6 l/s 103 Size (LxHxP) 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 Selection guide Air Cooled Heat Pump Chiller Range Capacity COP Flow rate Acoustic Power Mini SysAqua DCI Size (LxHxP) Mini SysAqua DCI 5 5 kw 3,24 0,24 l/s 58 990 x 966 x 354 Mini SysAqua DCI 7 7 kw 3,20 0,33 l/s 58 990 x 966 x 354 Mini SysAqua DCI 10 10 kw 3,39 0,48 l/s 59 990 x 1327 x 354 Mini SysAqua DCI 12 11.2 kw 3,31 0,53 l/s 59 990 x 1327 x 354 Mini SysAqua DCI 14 12.5 kw 3,25 0,60 l/s 60 990 x 1327 x 354 Mini SysAqua DCI 16 14.5 kw 3,30 0,69 l/s 60 990 x 1327 x 354 SyScroll 20-30 Air EVO HP SyScroll 20 Air EVO HP SyScroll 30 Air EVO HP 20,4 kw 3,17 0,975 l/s 74 26,1 kw 3,1 1,247 l/s 75 1.477 x 1.615 x 539 1.477 x 1.615 x 539 SyScroll 20-35 Air HP SysAqua H SyScroll 20 Air HP 20,9 kw 3,12 0,99 l/s 73 1.477 x 1.615 x 539 SyScroll 25 Air HP 24,5 kw 3,19 1,17 l/s 74 1.477 x 1.615 x 539 SyScroll 30 Air HP 28,4 kw 3,26 1,35 l/s 74 1.477 x 1.615 x 539 SyScroll 35 Air HP 35 kw 3,24 1,67 l/s 75 1.477 x 1.615 x 539 SysAqua 25 H 26,9 kw 2,91 1,28 l/s 75 1.000 x 1.983 x 1.000 SysAqua 30 H 29,7 kw 3,02 1,41 l/s 75 1.000 x 1.983 x 1.000 SysAqua 35 H 37,3 kw 2,82 1,78 l/s 76 1.000 x 1.983 x 1.000 SysAqua 40 H 41,6 kw 3,04 1,98 l/s 76 1.000 x 1.983 x 1.000

16 Air cooled Chiller & Heat Pump Selection guide Air Cooled Heat Pump Product Range Capacity COP Flow rate Acoustic Power SyScroll 40-75 Air HP SysAqua H SyScroll 85-135 Air HP AQVH 85-140 SyScroll 140-360 Air Evo HP SyScroll 40 Air HP SyScroll 45 Air HP SyScroll 50 Air HP SyScroll 60 Air HP SyScroll 65 Air HP SyScroll 75 Air HP 39,2 kw 2,95 1,74 l/s 80 43,7 kw 3,01 1,95 l/s 81 51,7 kw 3,17 2,27 l/s 81 58 kw 2,72 2,67 l/s 85 69,1 kw 3 3,02 l/s 86 76,3 kw 2,84 3,37 l/s 86 Size (LxHxP) 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 SysAqua 45 H 50 kw 2,80 2,38 l/s 79 2.180 x 1.986 x 1.160 SysAqua 55 H 58,4 kw 2,86 2,79 l/s 79 2.180 x 1.986 x 1.160 SysAqua 65 H 69,6 kw 3,06 3,32 l/s 79 2.180 x 1.986 x 1.160 SysAqua 75 H 75,9 kw 3,12 3,62 l/s 79 2.180 x 1.986 x 1.160 SysAqua 90 H 88 kw 2,62 4,20 l/s 82 2.180 x 2.286 x 1.160 SysAqua 105 H 101 kw 2,63 4,82 l/s 82 2.180 x 2.286 x 1.160 SysAqua 125 H 119 kw 2,62 5,68 l/s 82 2.180 x 2.286 x 1.160 SyScroll 85 Air HP 85 kw 3,14 3,77 l/s 84 3.000 x 2.250 x 1.100 SyScroll 95 Air HP 96 kw 3,12 4,16 l/s 84 3.000 x 2.250 x 1.100 SyScroll 105 Air HP 107 kw 2,82 4,69 l/s 88 3.000 x 2.250 x 1.100 SyScroll 120 Air HP 120 kw 2,82 5,44 l/s 88 3.500 x 2.250 x 1.100 SyScroll 135 Air HP 132,6 kw 2,81 5,97 l/s 88 3.500 x 2.250 x 1.100 AQVH 85 87 kw 3,39 3,87 l/s 85 2.555 x 2.185 x 1.095 AQVH 95 100,4 kw 3,23 4,30 l/s 85 2.555 x 2.185 x 1.095 AQVH 105 108,3 kw 3,29 4,73 l/s 85 2.555 x 2.185 x 1.095 AQVH 115 116,4 kw 3,26 5,11 l/s 85 2.555 x 2.185 x 1.095 AQVH 125 131,5 kw 3,13 5,55 l/s 89 3.155 x 2.185 x 1.095 AQVH 140 143,6 kw 3,14 6,19 l/s 89 3.155 x 2.185 x 1.095 SyScroll 140 Air Evo HP SyScroll 170 Air Evo HP SyScroll 200 Air Evo HP SyScroll 230 Air Evo HP SyScroll 260 Air Evo HP SyScroll 280 Air Evo HP SyScroll 300 Air Evo HP SyScroll 330 Air Evo HP SyScroll 360 Air Evo HP 144,9 kw 3,23 6,8 l/s 90 165,7 kw 3,21 7,88 l/s 90 200,1 kw 3,22 9,52 l/s 92 229 kw 3,23 10,91 l/s 92 262,3 kw 3,21 12,50 l/s 93 279,6 kw 3,2 13,30 l/s 93 305,6 kw 3,22 14,55 l/s 94 327,2 kw 3,21 15,58 l/s 95 361,4 kw 3,21 17,22 l/s 95 4.000 x 2.600 x 1.100 4.000 x 2.600 x 1.100 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 132,1 kw

Air cooled Chiller & Heat Pump 17 Air Cooled Chiller & Heat Pump Product Range Capacity COP Flow rate Acoustic Power VLH 604-1204 SyScroll 240-660 Air HP AQWH 1404-2406 VLH 604 169,8 kw 2,93 8,11 l/s 93 VLH 704 200,1 kw 2,97 9,56 l/s 93 VLH 804 223,2 kw 3,17 10,66 l/s 93 VLH 904 254,7 kw 3,2 12,17 l/s 94 VLH 1004 270,8 kw 3,09 12,94 l/s 94 VLH 1104 302,1 kw 3,02 14,43 l/s 95 VLH 1204 337,4 kw 3,00 16,12 l/s 95 Size (LxHxP) 3.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 SyScroll 240 Air HP 255,9 kw 2,76 12,16 l/s 93 3.500 x 2.600 x 2.150 SyScroll 270 Air HP 289,1 kw 2,71 13,72 l/s 93 3.500 x 2.600 x 2.150 SyScroll 290 Air HP 313,3 kw 2,68 14,86 l/s 94 3.500 x 2.600 x 2.150 SyScroll 320 Air HP 333 kw 2,84 15,86 l/s 94 3.500 x 2.600 x 2.150 SyScroll 360 Air HP 382,4 kw 2,81 18,19 l/s 94 4.550 x 2.600 x 2.150 SyScroll 420 Air HP 444 kw 2,78 21,11 l/s 95 4.550 x 2.600 x 2.150 SyScroll 470 Air HP 491,5 kw 2,88 23,38 l/s 95 5.600 x 2.600 x 2.150 SyScroll 540 Air HP SyScroll 590 Air HP SyScroll 660 Air HP 556,4 kw 605 kw 679,1 kw 2,91 26,47 l/s 96 2,89 28,77 l/s 96 2,94 32,27 l/s 97 AQWH 1404 420 kw 3,17 20,06 l/s 97 AQWH 1604 470,1 kw 3,21 22,46 l/s 97 AQWH 1806 548,3 kw 3,18 26,19 l/s 98 AQWH 2106 627,2 kw 3,23 29,96 l/s 98 AQWH 2406 702 kw 3,18 33,54 l/s 98 5.600 x 2.600 x 2.150 6.650 x 2.600 x 2.150 6.650 x 2.600 x 2.150 4.000 x 2.550 x 2.200 4.000 x 2.550 x 2.200 5.000 x 2.550 x 2.200 6.000 x 2.550 x 2.200 6.000 x 2.550 x 2.200

18 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 20-35 Air CO 20-33 kw Plate 410A Air cooled Scroll Technical feature 4 sizes Cooling capacity from 20,8 to 33,7 kw One refrigerant circuit One scroll compressor New control Operating low water content in the plant Pump as standard Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coil grilles Coils treatment Desuperheater Electronic expansion valve Fan speed control (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water differential pressure switch (standard) Water filter (standard) Water flow switch SyScroll 20-35 Air CO - Cooling Operation OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Water+ Glycol+EEV Water -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) Operating limit (to be confirmed following selection software issue) SyScroll 20-35 Air CO 20 25 30 35 Min - Max Leaving water temperature * C from -8 to +18 T water K 3-7 Air temperature C Refer to below graphich * Below 5 C, glycol and electronic expansion valve is required. Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kw of cooling capacity.

Caratteristiche tecniche AQL 20 35 Technical feature Air cooled Chiller & Heat Pump 19 Air Cooled Chiller & Heat Pump SyScroll 20-35 Air CO 20 25 30 35 Cooling capacity 1 kw 20,8 24,4 28,2 33,7 Power input 1 kw 6,67 7,41 8,97 11,5 EER 100% 1 3,12 3,29 3,14 2,93 Energy Efficiency Class A A A B ESEER 3,56 3,77 3,70 3,44 Part load steps % 0-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 1 Scroll Crankcase heater W 70 90 90 90 Internal heat exchanger Qty 1 Plate exchanger AISI 316 Water flow l/s 0,97 1,14 1,32 1,59 Available Static Pressure kpa 169 152 144 114 Antifreeze heater W 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 1 1/4 Water drain connection inch ⅜ Fan Qty 2 Axial Air flow m 3 /h 10.957 10.425 10.425 9.919 Power input kw 0,54 0,54 0,54 0,55 Pump Qty 1 Power input kw 0,57 0,60 0,63 0,65 Weight Shipping kg 254 285 289 304 Operating kg 248 279 283 298 Dimensions Lenght mm 1.477 1.477 1.477 1.477 Width mm 539 539 539 539 Height mm 1.615 1.615 1.615 1.615 Acoustical data Sound power level 3 db(a) 73 74 74 75 Sound pressure level at 10 m 4 db(a) 41 42 42 43 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.

20 Air cooled Chiller & Heat Pump Air Cooled Chiller SysAqua 25-40 L 25-37 kw Plate 410A Air cooled Scroll Technical feature 4 sizes Cooling capacity from 26.6 to 39.3 kw Refrigerant R410A EER up to 3.09 ESSEER up to 4.07 Main function Available with one cooling circuit Tandem scroll per refrigerant circuit Extented operating limits STD operating up to +7 C external Available versions Low sound level Standard High temperature operation up to 50 C (STD) Return or leaving water temperature control With Hydraulic kit 1 pump STD Product Advantages Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 lt/kw Low footprint Easy maintenance Low water pressure drop Set point compensation (standard) Night mode (extra low sound level) (standard) ON OFF Remote Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Closed cabinet with inside the thermodynamic and hydraulic parts Main accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-10 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete hydraulic kit 1 pump medium pressure Standard Rubber antivibration pad Water level pressure switch Water tank 100 l High pressure fan Operating limit (to be confirmed following selection software issue) SysAqua 25-40 L Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External air temperature (Maximum) External air temperature (Minimum) +5 C / +18 C +2 C +50 C -10 C

Technical feature Air cooled Chiller & Heat Pump 21 Air Cooled Chiller & Heat Pump SysAqua 25-40 L 25 30 35 40 Cooling Capacity kw 26,6 28,3 37,6 39,3 Power input kw 8,6 9,34 13,49 13,6 Total EER 100% ** 3,09 3,03 2,97 2,88 ESEER ** 3,97 3,96 4,07 3,90 Energy Efficiency Class B B B C Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Nominal current A 15,1 16,3 24 24 Maximum operating current A 18,2 21 29,6 30 Inrush current A 61 75 115 118 Refrigerant HFC 410A Number refrigerant circuits 1 1 1 1 Compressor Quantity 2 2 2 2 Scroll Scroll Scroll Scroll N capactity steps % 0/50/100 0/50/100 0/50/100 0/50/100 Crankcase heater W 40 70 70 70 Evaporator Qty 1 1 1 1 Plate Plate Plate Plate Water flow rate m³/h 4,3 4,6 6,1 6,3 Water pressure drop kpa 37 22 37 37 Water volume l 1,78 2,55 2,55 2,55 Antifreeze heater W 30 30 30 30 Coil Qty 1 1 1 1 Total coil face area per coil m 2 2,4 2,4 2,8 2,8 Fan motors Qty 1 1 1 1 Air flow m³/h 13.000 13.000 16.000 16.000 Speed tr/mn 900 900 650 650 Power input (unitary) W 940 940 930 930 Pump Qty Option 1 or 2 Pumps Power input Option 1 or 2 Pumps Available static pressure Option 1 or 2 Pumps Hydraulic connexion Male Gas Threaded Inlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Outlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Dimensions Length mm 1.000 1.000 1.000 1.000 Width mm 1.000 1.000 1.000 1.000 Height mm 1.983 1.983 1.983 1.983 Weight Operating kg 300 330 340 340 Acoustical data Sound power level * db(a) 75 75 76 76 * 0 Following Eurovent standard. ** 0Following Eurovent 14511.

22 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 40-75 Air CO 41-77 kw Plate 410A Air cooled Scroll Technical feature 6 sizes Cooling capacity from 40,8 to 76,7 kw 3 versions: STD (standard version) HT ( High Temperature) HPF (High Pressure Fans) 2 Low Noise versions: Standard version (STD) Super Low Noise version (S) One refrigerant circuit 2 scroll compressors (one tandem) Operating low water content in the plant Brine version for process application Accessories and options Automatic circuit breaker Coils treatments Coils grilles (standard) Compressors jackets (standard S) Electronic expansion valves Overload protection for compressors Sequencer for up to 4 chillers installation Desuperheater Fan speed control ( down to -18 C) Hydrokit with 1 or 2 pumps with or without buffer tank Hydrometer (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter (standard) Water differential switch (standard) Water flow switch (standard)

Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 23 Air Cooled Chiller & Heat Pump SyScroll 40-75 Air CO 40 45 50 60 65 75 Min - Max Leaving water temperature * C from -8 to +18 Water T K 3-7 Air Temperature C Refers to following graphics * Below 5 C, glycol and electronic expansion valve are required. Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kw of output. BLN Version S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 - 10 Water + Glycol + EEV Water Water+ Glycol + EEV + FSC Water+ FSC -9-8 -7-6 -5-4 -3-2-1 0 1 2 3 4 5 6 7 8 9 1011121314151617181 920 LWT ( C) OAT ( C) 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 - 10 Water+ Glycol + EEV Water Water+ Glycol + EEV + FSC Water+ FSC -9-8 -7-6 -5-4 -3-2 -1 0 1 2 3 4 5 6 7 8 9 10 11121314151617181920 LWT ( C) HT Version 55 50 45 40 35 30 25 20 15 10 Water+ Glycol + EEV Water 5 0-5 -10-15 -20-25 - 10-9 -8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 1011 12131415161718192 0 T OAT ( C) 40-50 60-75 LWT ( C)

24 Air cooled Chiller & Heat Pump Technical feature SyScroll 40-75 Air CO (STD-HPF-HT) 40 45 50 60 65 75 Cooling capacity 1 kw 40,8 44,8 51,9 60,9 68,9 76,7 Power input 1 kw 14,0 16,2 18,6 20,5 23,5 27,9 EER 1 2,91 2,77 2,79 2,97 2,93 2,75 Energy Efficiency Class B C C B B C ESEER 4,08 3,87 3,89 4,01 4,07 3,73 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Diretto Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 2 2 2 2 2 2 Scroll Cranckcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.884 7.572 8.774 10.317 11.680 13.032 Antifreeze heater W 35 35 35 35 35 35 Connection type Male GAS threaded Inlet/outlet diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 14.000 14.000 13.200 21.100 21.100 21.100 Speed rpm/min 680 680 680 900 900 900 Power input kw 0,98 0,98 0,98 2,00 2,00 2,00 Power input * kw 2,67 2,67 2,67 2,67 2,67 2,67 Available static pressure * Pa from 0 to 120 Weight Shipping kg 403 411 436 476 483 488 Operating kg 413 421 446 489 496 502 Dimensions Lenght mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 78 79 79 83 84 84 Sound pressure level at 10 m 3 db(a) 47 47 47 52 52 52 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * HPF / HT versions with EC fan motor.

Caratteristiche Technical feature tecniche AQL 20 35 Air cooled Chiller & Heat Pump 25 Air Cooled Chiller & Heat Pump SyScroll 40-75 Air CO S 40 45 50 60 65 75 Cooling capacity 1 kw 39,4 43,1 49,6 59,0 64,0 73,7 Power input 1 kw 14,3 16,6 19,4 20,7 23,6 28,7 EER 1 2,76 2,60 2,56 2,85 2,71 2,57 Energy Efficiency Class C D D C C D ESEER 3,87 3,62 3,58 3,85 3,77 3,50 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 2 2 2 2 2 2 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.656 7.293 8.376 9.976 10.853 12.522 Antifreeze heater W 35 35 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 11.000 11.000 10.300 16.000 16.000 16.000 Speed rpm/min 530 530 530 720 720 720 Power input kw 0,57 0,57 0,57 1,27 1,27 1,27 Weight Shipping kg 403 411 436 476 483 488 Operating kg 413 421 446 489 496 502 Dimensions Lenght mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 74 75 75 78 79 79 Sound pressure level at 10 m 3 db(a) 42 44 44 46 47 47 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.

26 Air cooled Chiller & Heat Pump Air Cooled Chiller SysAqua 45-125 L 49.1-128 kw Plate 410A Air cooled Scroll Technical feature Cooling capacity from 49.1 to 128 kw 7 sizes Refrigerant: R410A EER up to 3.13 ESSEER up to 4.14 Main functions Available with one cooling circuit Tandem scroll per refrigerant circuit Extented operating limits STD operating up to +7 C external T Product Advantages Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 lt/kw Low footprint Easy maintenance Low water pressure drop Set point compensation (standard) Night mode (extra low sound level) std ON OFF Remote Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-10 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 2 pumps medium pressure Rubber antivibration pad Water level pressure switch Water tank 300lt High pressure fan Operating limit (to be confirmed following selection software issue) SysAqua 45-125 L Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External air temperature (Maximum) External air temperature (Minimum) +5 C / +18 C +2 C +50 C -10 C

Technical feature Air cooled Chiller & Heat Pump 27 Air Cooled Chiller & Heat Pump SysAqua 45-125 L 45 55 65 75 90 105 125 Cooling Capacity kw 49,1 56 69,1 75,1 96 111,5 128 Power input kw 16,9 19,67 22,1 24,3 34,36 38,06 46,4 Total EER 100% ** 2,91 2,85 3,13 3,1 2,79 2,93 2,76 ESEER ** 4,06 4,08 4,2 4,17 4,01 4,04 4,02 Energy Efficiency Class B C A A C B C Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Direct Direct Direct Nominal current A 30 35 42 47 62 69 84 Maximum operating current A 34 39 52 57 67 77 92 Inrush current A 126 134 195 201 250 300 330 Refrigerant HFC 410A Number refrigerant circuits 1 1 1 1 1 1 1 Compressor Quantity cooling cicuits 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll N capactity steps % 0/50/100 0/45/ 55/100 0/40/ 60/100 0/45/ 55/100 0/45/ 55/100 0/40/ 60/100 0/33/ 67/100 Crankcrase heater W 2 * 90 2 * 90 2 * 90 2 * 90 140 90/140 90/140 Evaporator Qty 1 1 1 1 1 1 1 Plate Plate Plate Plate Plate Plate Plate Water flow rate m 3 /h 8 9,1 11,3 12,3 15,7 18,2 20,9 Water pressure drop kpa 27 35 28 33 26 34 45 Water volume l 4,1 4,1 6,1 6,1 10,8 10,8 10,8 Antifreeze heater W 30 30 2 * 30 2 * 30 2 * 30 2 * 30 2 * 30 Coil Qty 1 1 2 2 2 2 2 Total coil face area per coil m 2 4,2 4,2 5,55 5,55 6,4 6,4 6,4 Fan motors Quantity 1 1 2 2 2 2 2 Air flow m 3 /h 22.500 22.500 30.000 30.000 42.000 42.000 42.000 Power input (unitary) W 2.100 2.100 930 930 2.100 2.100 2.100 Pumps Qty Option 1 ou 2 pumps Power input kw Option 1 ou 2 pumps Available static pressure Kpa Option 1 ou 2 pumps Hydraulic Connection Male GAS Threaded Inlet diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Outlet diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Dimensions Length mm 2.180 2.180 2.180 2.180 2.180 2.180 2.180 Width mm 1.160 1.160 1.160 1.160 1.160 1.160 1.160 Height mm 1.986 1.986 1.986 1.986 2.286 2.286 2.286 Weight Operating kg 490 490 560 560 870 980 1.000 Acoustical data Sound power level * db(a) 79 79 79 79 82 82 82 * Following Eurovent standard. ** Following Eurovent 14511.

28 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 85-135 Air CO 84-132 kw Plate 410A Air cooled Scroll Technical feature 5 sizes Cooling capacity from 84,2 to 132,1 kw 3 Versions: STD (Standard version) HT (High Temperature version) HPF (High Pressure Fans version) 2 acoustic versions: Standard version (STD) Super Low Noise version (S) One refrigerant circuit 2 Scroll compressors (Tandem) Microchannel coils Microprocessor control Electronic expansion valve as standard E-Coating coil treatment as standard Brine version for process application Accessories and options Hydrokit with 1 or 2 pumps with or without buffer tank Desuperheater Unit protection grilles Sofstart BMS interface Overload protection for compressors Automatic circuit breaker Water flow switch (standard) Mechanical gauges Fan speed control Water pressure switch Water filter Power factor corrector capacitors Compressors acoustic box (standard) Sequence phases control (standard) Compressors jackets

Operating Limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 29 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air CO Leaving water temperature Air temperature External static pressure Min 85-135 Water С +6 +18 Water with glycol + electonic expansion valve * С -8 +5 T Water К 3 7 BLN С +10 +45 S С -14 +42 HT С -16 +47 Standard fans Pa 0 High pressure fans (HPF) Pa < 120 Max * For operation below 0 C contact sales office. STD Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 1012 1416 18 LWT ( C) HT Version OAT ( C) 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C)

30 Air cooled Chiller & Heat Pump Technical feature SyScroll 85-135 Air CO 85 95 105 120 135 Cooling capacity 1 kw 84,2 93,2 104,6 118,6 132,1 Power input 1 kw 27,2 31,5 37,7 42,0 47,6 EER 1 3,09 2,96 2,77 2,82 2,78 Energy efficiency class B C C C C ESEER 3,94 4,35 4,00 4,01 4,03 Part load steps 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 14,5 16,0 18,0 20,4 22,7 Water pressure drop kpa 26 32 28 22 19 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil m 2 2,4 3,1 Fan Qty 2 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 2 db(a) 84 84 88 88 88 Sound pressure level 3 db(a) 52 52 56 56 56 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.

Technical feature Air cooled Chiller & Heat Pump 31 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air CO S 85 95 105 120 135 Cooling capacity 1 kw 81,1 89,3 101,4 113,5 126,0 Power input 1 kw 28,0 32,8 38,6 43,0 49,6 EER 1 2,90 2,72 2,63 2,64 2,54 Energy efficiency class C C D D D ESEER 3,91 4,32 3,98 4,03 4,00 Part load steps % 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 13,9 15,4 17,4 19,5 21,7 Water pressure drop kpa 23 28 25 20 17 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil m 2 2,4 3,1 Fans Qty 2 Air flow rate m 3 /h 25.000 34.000 36.000 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 2 db(a) 82 82 85 85 85 Sound pressure level 3 db(a) 50 50 53 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.

32 Air cooled Chiller & Heat Pump Air Cooled Chiller AQVL 85-140 83-137 kw Plate 410A Air cooled Scroll Technical feature 6 sizes Cooling capacity from 83,3 to 136,5 kw 4 versions: STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions: Standard version (STD), Extra Low Noise version (ELN) Two refrigerant circuits Scroll compressors Microprocessor control Low operating water content in the plant Electronic expansion valve as standard Brine version for process application E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets as standard on ELN Desuperheater & Totaly heat recovery Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Pressure switch Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure & Water flow switch (standard) Water filter Operating limit (to be confirmed following selection software issue) AQVL 85-140 Min Max Leaving water temperature Air temperature External static pressure 55 50 45 40 35 30 25 20 15 10 Water+ Glycol + EEV Water 5 0-5 -10-15 -20-25 - 10-9 -8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 1011 12131415161718192 0 OAT ( C) LWT ( C) 85-115 125-140 Water С +5 +18 Water with glycol С 0 +18 Water with glycol (Brine version) C -8 +18 BLN С +5 +47 ELN С -18 +44 HSE/HT С -18 Standard fans Pa 0 High Pressure Fans (HPF) Pa < 120 +50 (85-115) +47 (125-140)

Technical feature Air cooled Chiller & Heat Pump 33 Air Cooled Chiller & Heat Pump AQVL 85-140 BLN 85 95 105 115 125 140 Cooling capacity 1 kw 83,3 93,3 102,6 110,5 121,6 136,5 Power input 1 kw 27,1 31,0 33,6 36,6 40,9 46,1 EER 1 3,08 3,01 3,05 3,02 2,97 2,96 Energy Efficiency class B B B B B B ESEER 4,16 4,15 4,07 4,12 3,95 4,01 EER HSE 1 3,19 3,09 3,13 3,10 3,05 3,03 Energy Efficiency class A B A A B B ESEER HSE 4,06 4,12 4,23 4,19 3,96 4,08 Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow m 3 /h 14.377 16.116 17.681 19.023 21.033 23.588 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil mm 2,4 2,4 2,4 2,4 3,1 3,1 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 34.000 34.000 33.200 32.400 44.000 42.800 Speed rpm/min 690 690 690 690 900 900 Power input kw 2,1 2,1 2,1 2,1 3,4 3,4 Power input HSE kw 1,2 1,2 1,2 1,2 2,4 2,4 Power input HPF kw 3,6 3,6 3,6 3,6 4,6 4,6 Weight Shipping kg 1.033 1.047 1.084 1.116 1.151 1.230 Operating kg 1.058 1.072 1.111 1.143 1.183 1.262 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 84 84 84 84 88 88 Sound pressure level 3 db(a) 52 52 52 52 56 56 Sound power level HPF 2 db(a) 92 92 92 92 95 95 Sound pressure level HPF 3 db(a) 60 60 60 60 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.

34 Air cooled Chiller & Heat Pump Technical feature AQVL 85-140 ELN 85 95 105 115 125 140 Cooling capacity 1 kw 80,6 89,9 98,3 105,6 119,6 133,5 Power input 1 kw 26,1 30,2 32,8 35,7 39,9 45,1 EER 1 2,87 2,75 2,77 2,73 2,90 2,86 Energy efficiency class C C C C B C ESEER 3,91 3,78 3,81 3,67 3,92 3,93 EER HSE 1 3,00 2,87 2,87 2,81 2,96 2,91 Energy efficiency class B C C C B B ESEER HSE 3,91 3,87 3,87 3,79 3,99 3,94 Part load steps % 0-25-50-75-10 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 13.906 15.532 16.971 18.204 20.550 22.988 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 3,1 3,1 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 25.200 25.200 24.600 24.000 36.500 35.000 Speed rpm/min 500 500 500 500 690 690 Power input kw 1,8 1,8 1,8 1,8 2,1 2,1 Power input HSE kw 0,6 0,6 0,6 0,6 1,2 1,2 Weight Shipping kg 1.063 1.077 1.114 1.146 1.181 1.260 Operating kg 1.088 1.102 1.141 1.173 1.213 1.292 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 82 82 82 82 86 86 Sound pressure level 3 db(a) 50 50 50 50 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.