Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Conditioning Light Commercial, Commercial and Industrial
Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is a question of cooperation, quality, deliveries or documentation. This catalogue is of course a part of this work. With this catalogue, which features products of air conditioning, we want to give you as a customer a general overview of what Systemair can offer within this field. More detailed information are available in our Online catalogue at www.systemair.com and as downloadable software. Systemair s range of fans, air distribution products and accessories also appears in our printed main catalogue. Our product development leads the field - latest technologies in unitdesign, fans, motors, heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power consumption. Systemair has grown each year since the start and we aim to continue with this trend. Systemair strives to be a reliable supplier of quality products. We help our customers to focus on their own business. Reliable deliveries give the customer greater possibilities to quickly complete a job, and move on to the next project. At Systemair we call this Trust. Systemair 2015. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com
Content 1 Content Systemair 2 Product Range 6 Application 8 Air Cooled Chiller & Heat Pumps 10 Water Cooled Chiller, Heat Pumps and Condensing Unit 131 Free-Cooling 155 Condensing Unit 161 Residential Heat Pump 190 Water Terminals 200 Water Source Heat Pump 228 Roof Top 240 Close control 246 Direct Expansion 252 Hydrokit HPT 262
Systemair 2 Systemair worldwide Skinnskatteberg, Sweden: Systemair AB, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. Also located here is the company s most advanced test installation for measuring technical data. Klockgården, Sweden: Systemair s small air handling units are manufactured at Klockgården in Skinnskatteberg. Frico s central warehouse of approximately 8000 m 2 is also located here. Windischbuch, Germany: Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center. Langenfeld, Germany: Production of air curtains. Hässleholm, Sweden: VEAB is the leading European manufacturer of electric duct heaters. Production of heating and cooling coils, electric and water based. Ukmerge, Lithuania: Production of smaller air handling units with energy recovery systems. Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified. Hasselager, Denmark: Production of modular air handling units. Dal Eidsvoll, Norway: Production of air handling units.
Systemair 3 Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Save energy, lower running cost! Our label Green Ventilation features products with a high energy saving potential. All products labelled with Green Ventilation combine energy economy with energy efficiency. Kansas City, USA Bouctouche, Canada Dal, Eidsvoll, Norway Skinnskatteberg, Sweden Hasselager, Denmark Hässleholm, Sweden Ukmerge, Lithuania Waalwijk, Netherlands Langenfeld, Germany Windischbuch, Germany Tillières-sur-Avre, France Bratislava, Slovakia Maribor, Slovenia Barlassina, Italy Madrid, Spain Istanbul, Turkey New Delhi, India Hyderabad, India Kuala Lumpur, Malaysia Bratislava, Slovakia: The factory in Bratislava manufactures air distribution products and EN certified fire and smoke dampers. Kuala Lumpur, Malaysia: Production and marketing of products for Tunnel and garage ventilation. Madrid, Spain: Production of air handling units for the southern European market. Hyderabad, India: Production of air distribution products. New Delhi, India: The factories in New Delhi and Noida manufacture grilles and diffusers. Barlassina, Italy: Our factory in Italy, Systemair, develops and manufactures a wide range of chiller and heat pump in A class from 20 to 1.700kW. Bouctouche, Canada: Our main North American production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche. Kansas City, USA: Production of fans for the US market. Istanbul, Turkey: Systemair-HSK is Turkey s leading manufacturer of air handling units. Waalwijk, Netherlands: Holland Heating is Netherlands leading manufacturer of air handling units. Tillières-sur-Avre, France: Our factory in France, Systemair, develops and manufactures: Roof top, water source heat pump, hight temperature heat pump, water terminals.
4 Systemair worldwide Systemair (France) The Factory of Tillières-sur-Avre The company Systemair AC, French factory of Systemair group, Founded in 1947 by Paul Vallet, is one of the globally leading manufactures and distributors air conditioning systems. Over 60 years of experience in the design, development and production of residential, commercial and industrial applications make Systemair an indispensable actor on the european market. References are numerous in France and internationally and concern all sectors of activity including many hospitals (surgery rooms, white rooms...) industrial sites, energy-efficient office buildings, hotels, and also under naval board. Our sales department will be able to illustrate our references according to your requests. The factory benefit from ISO certifications 9001 freed delivered by the most recognized certification bodies. Besides, Systemair AC participates in the certification programme Eurovent insuring by independent laboratories the check of the technical specifications according to the international standards. Production The Factory in France, Extends over a total area of 36.000 sqm with 150 employees. The number of employees, including the organization of sales is more than 200 people. Range The factory develops and manufactures a wide range of air conditionning produts: Chillers & Heat Pumps Water Terminals Residential heat pump Water Source Heat Pump Close control Direct expansion. Brand Products of French factory, are sold under systemair brand.
Systemair (Italy) Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Systemair 5 Save energy, lower running Systemair cost! Our label Green Ventilation features products with a high energy saving potential. All products labelled with Green Ventilation combine energy economy with energy efficiency. The factory of Barlassina The company Systemair, Italian factory of Systemair Group, is important in equipment for HVAC s market from 20 to 1.700 kw suitable for a wide range of applications of air conditioning and industrial processes. Systemair has 70 years experience in the industrial production, of which 50 years in HVAC business. Systemair Italy is equipped with high tech equipment and has one of the most modern research centers in Europe for the devlopment and testing the of chillers and heat pumps. The range of product, that is Eurovent certified, consist of Air and Water cooled chillers and heat pumps as well as condensing and conderseless unit. Range The factory, develops and manufactures a wide range of air conditioning produts: Chillers & Heat Pumps Condensing Unit Close control. Brand Products of our Italian factory, are sold under systemair brand. Production The factory in Italy extend over a total area of 33.400 sqm and a manufacture area over of 19.400 sqm with around 200 employees.
6 Product range Product range Systemair has an extensive range of ventilation products: fans including smoke extractor, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc. Fans Systemair has the wider range of fans for use in different applications. Our range includes any type of fans, from circular ducts hystorical product boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. All products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. All our fans are designed to meet the strict requirements, easy to use, high quality and durability. Duct fans Duct fans for circular duct installation. Centrifugal fans Centrifugal supply single fans. Rectangular duct fans Duct fans with rectangular connection. Square duct fans For different applications, there are models for ambient with high temperature. Axial fans Axial fans for duct or wall application. Roof fans Roof fans with circular or square connection. Explosion proof fans Explosion proof fans in duct, roof or wall design. Jet Axial Fans Jet Axial Fans for car park, tunnels and air overpression. High temperature fans Systemair provides high fire resistance fans till 600 C/2 hours.
Product range 7 Air handling units Systemair produces a wide range of air handling units for several applications, from small office to large industrial building. All range is been developped to satisfy strict needs of low energy consumption. Fire and smoke dampers Smoke extract fans High efficient fans to extract the combustion smoke. Fire & smoke dampers Dampers that reduce the spread of smoke and fire. Residential ventilation Complete energy-efficient air handling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics. Residential units For homes with living areas of 60-320 m 2. Cooker hoods Ideal for capturing odours even at low airflows. Air distribution products The range also includes a wide selection of air distribution products and accessories. Supply, extract & transfer devices For mounting in ceilings or walls. Nozzle diffusers Optimum flexibility and comfort in air distribution for rooms.
Applications Schools In buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the required flexibility. Offices In buildings for tertiary application, the air conditioning and the ventilation are necessary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines. Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices.
Commercial buildings Normally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant monitoring of concentration of pollutants (VOC and CO 2 ). Systemair ACʼs products can easily meet the plantʼs requirement. Industry Industrial plants generate a large amount of heat that must be dissipated in the appropriate way. Systemair AC offers a wide range of products (chillers from 20 kw to 1.700 kw) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10 C). Hotels In the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact, required by this type of installations.
Air Cooled Chiller & Heat Pump Mini SysAqua DCI 5-16 5-14.5 kw 5.5-16 kw 410A Rotary Inverter Plate INVERTER SysAqua 45 to 125 L-H 46-122 kw 50-120 kw 410A Scroll Plate SyScroll 20-30 Air EVO HP 20-36 kw 20-34 kw 410A Scroll Inverter Plate SyScroll 85-135 Air CO-HP 84-132 kw 85-133 kw 410A Scroll Plate SyScroll 20-35 Air CO-HP 21-34 kw 21-35 kw 410A Scroll Plate AQVL/AQVH 85-140 85-137 kw 87-144 kw 410A Scroll Plate SysAqua 25-40 L-H 25-37 kw 27-40 kw 410A Scroll Plate SyScroll 140-360 Air EVO CO-HP 144-361 kw 145-361 kw 410A Scroll Plate SyScroll 40-75 Air CO-HP 41-77 kw 39-76 kw 410A Scroll Plate SyScroll 240-660 Air CO-HP 238-654 kw 256-679 kw 410A Scroll Plate INVERTER
VLS/VLH 604-1204 153-307 kw 170-337 kw 410A Scroll Plate AQWH 1404-2406 359-602 kw 420-702 kw 410A Scroll Plate SyScrew 360-1300 Air CO 365-1.316 kw 134a Screw Shell & Tube SyScrew 370-1100 Air EVO CO 364-1.118 kw 134a Screw Shell & Tube SLS HE 5204-8404 1.142-1.687 kw 134a Screw S&T evaporator
12 Air cooled Chiller & Heat Pump Selection guide Air Cooled Chiller Product Range Capacity EER Flow rate Acoustic Power SyScroll 20-35 Air CO SysAqua L SyScroll 40-75 Air CO SysAqua L SyScroll 85-135 Air CO AQVL 85-140 Size (LxHxP) SyScroll 20 Air CO 20,8 kw 3,12 0,97 l/s 73 1.477 x 1.615 x 539 SyScroll 25 Air CO 24,4 kw 3,29 1,14 l/s 74 1.477 x 1.615 x 539 SyScroll 30 Air CO 28,2 kw 3,14 1,32 l/s 74 1.477 x 1.615 x 539 SyScroll 35 Air CO 33,7 kw 2,93 1,59 l/s 75 1.477 x 1.615 x 539 SysAqua 25 L 26,6 kw 3,09 1,19 l/s 75 1.000 x 1.983 x 1.000 SysAqua 30 L 28,3 kw 3,03 1,27 l/s 75 1.000 x 1.983 x 1.000 SysAqua 35 L 37,6 kw 2,97 1,69 l/s 76 1.000 x 1.983 x 1.000 SysAqua 40 L 39,3 kw 2,88 1,75 l/s 76 1.000 x 1.983 x 1.000 SyScroll 40 Air CO SyScroll 45 Air CO SyScroll 50 Air CO SyScroll 60 Air CO SyScroll 65 Air CO SyScroll 75 Air CO 40,8 kw 2,91 1,9 l/s 80 44,8 kw 2,77 2,1 l/s 81 51,9 kw 2,79 2,4 l/s 81 60,9 kw 2,97 2,8 l/s 85 68,9 kw 2,93 3,2 l/s 86 76,7 kw 2,75 3,6 l/s 86 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 SysAqua 45 L 49,1 kw 2,91 2,22 l/s 79 2.180 x 1.986 x 1.160 SysAqua 55 L 56 kw 2,85 2,52 l/s 79 2.180 x 1.986 x 1.160 SysAqua 65 L 69,1 kw 3,13 3,13 l/s 79 2.180 x 1.986 x 1.160 SysAqua 75 L 75,1 kw 3,10 3,41 l/s 79 2.180 x 1.986 x 1.160 SysAqua 90 L 96,0 kw 2,79 4,36 l/s 82 2.180 x 1.986 x 1.160 SysAqua 105 L 111,5 kw 2,93 5,05 l/s 82 2.180 x 1.986 x 1.160 SysAqua 125 L 2,76 5,80 l/s 82 2.180 x 1.986 x 1.160 SyScroll 85 Air CO 84,2 kw 3,09 4,02 l/s 84 3.000 x 2.250 x 1.100 SyScroll 95 Air CO 93,2 kw 2,96 4,44 l/s 84 3.000 x 2.250 x 1.100 SyScroll 105 Air CO 104,6 kw 2,77 5 l/s 88 3.000 x 2.250 x 1.100 SyScroll 120 Air CO 118,6 kw 2,82 5,6 l/s 88 3.500 x 2.250 x 1.100 SyScroll 135 Air CO 128 kw 132,1 kw 2,78 6,3 l/s 88 AQVL 85 83,3 kw 3,08 3,9 l/s 85 AQVL 95 93,3 3,01 4,4 l/s 85 AQVL 105 102,6 kw 3,05 4,9 l/s 85 AQVL 115 110,5 kw 3,02 5,2 l/s 85 AQVL 125 121,6 kw 2,97 5,8 l/s 89 AQVL 140 136,5 kw 2,96 6,5 l/s 89 3.500 x 2.250 x 1.100 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 2.555 x 2.185 x 1.095 3.155 x 2.185 x 1.095 3.155 x 2.185 x 1.095
Air cooled Chiller & Heat Pump 13 Air Cooled Chiller & Heat Pump Product Range Capacity EER Flow rate Acoustic Power SyScroll 140-360 Air Evo CO VLS 604-1204 SyScroll 240-660 Air CO SyScroll 140 Air Evo CO SyScroll 170 Air Evo CO SyScroll 200 Air Evo CO SyScroll 230 Air Evo CO SyScroll 260 Air Evo CO SyScroll 280 Air Evo CO SyScroll 300 Air Evo CO SyScroll 330 Air Evo CO SyScroll 360 Air Evo CO 144 kw 3,22 6,9 l/s 90 168,6 kw 3,11 8,0 l/s 90 196,4 kw 3,17 9,4 l/s 92 229,9 kw 3,11 11,0 l/s 92 262,6 kw 3,15 12,5 l/s 93 283,5 kw 3,14 13,5 l/s 93 309,3 kw 3,14 14,8 l/s 94 330,3 kw 3,18 15,8 l/s 95 360,7 kw 3,11 17,2 l/s 95 VLS 604 153,4 kw 2,75 7,3 l/s 93 VLS 704 176,2 kw 2,67 8,4 l/s 93 VLS 804 198,1 kw 2,74 9,4 l/s 93 VLS 904 228,4 kw 2,75 10,9 l/s 94 VLS 1004 250,3 kw 2,88 11,9 l/s 94 VLS 1104 279,1 kw 2,79 13,3 l/s 95 VLS1204 306,9 kw 2,67 14,7 l/s 95 Size (LxHxP) 4.000 x 2.600 x 1.100 4.000 x 2.600 x 1.100 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 3.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 SyScroll 240 Air CO 238,1 kw 2,84 11,4 l/s 93 3.500 x 2.600 x 2.150 SyScroll 270 Air CO 267,4 kw 2,7 12,8 l/s 93 3.500 x 2.600 x 2.150 SyScroll 290 Air CO 287,4 kw 2,78 13,8 l/s 94 3.500 x 2.600 x 2.150 SyScroll 320 Air CO 316,1 kw 2,83 15,13 l/s 94 3.500 x 2.600 x 2.150 SyScroll 360 Air CO 362 kw 2,82 17,3 l/s 94 4.550 x 2.600 x 2.150 SyScroll 420 Air CO 414,2 kw 2,78 19,8 l/s 95 4.550 x 2.600 x 2.150 SyScroll 470 Air CO 469,6 kw 2,92 22,5 l/s 95 5.600 x 2.600 x 2.150 SyScroll 540 Air CO SyScroll 590 Air CO SyScroll 660 Air CO 533,7 kw 588,9 kw 654,2 kw 2,9 25,6 l/s 96 2,97 28,2 l/s 96 2,95 31,4 l/s 97 5.600 x 2.600 x 2.150 6.650 x 2.600 x 2.150 6.650 x 2.600 x 2.150
14 Air cooled Chiller & Heat Pump Selection guide Air Cooled Chiller Product Range Capacity EER Flow rate Acoustic Power SyScrew 370-1100 Air EVO CO SyScrew 360-1300 Air CO Size (LxHxP) SyScrew 370 Air EVO CO 364,1 kw 3,23 17,3 l/s 97 4.600 x 2.550 x 2.200 SyScrew 400 Air EVO CO 414,5 kw 3,18 19,8 l/s 98 5.700 x 2.550 x 2.200 SyScrew 450 Air EVO CO 445,5 kw 3,11 21,2 l/s 98 5.700 x 2.550 x 2.200 SyScrew 500 Air EVO CO 502,9 kw 3,15 24,0 l/s 98 5.700 x 2.550 x 2.200 SyScrew 570 Air EVO CO 562,1 kw 3,18 26,8 l/s 99 6.700 x 2.550 x 2.200 SyScrew 650 Air EVO CO 625,5 kw 3,16 29,8 l/s 99 6.700 x 2.550 x 2.200 SyScrew 700 Air EVO CO 712,9 kw 3,19 34,0 l/s 99 7.800 x 2.550 x 2.200 SyScrew 750 Air EVO CO 749,2 kw 3,16 35,7 l/s 100 7.800 x 2.550 x 2.200 SyScrew 850 Air EVO CO 839 kw 3,21 40,0 l/s 100 8.800 x 2.550 x 2.200 SyScrew 950 Air EVO CO 961,8 kw 3,33 45,9 l/s 101 9.900 x 2.550 x 2.200 SyScrew 1000 Air EVO CO 1.019 kw 3,26 48,6 l/s 101,00 10.900 x 2.550 x 2.200 SyScrew 1100 Air EVO CO 1.117,90 kw 3,29 53,4 l/s 102,00 12.000 x 2.550 x 2.200 SyScrew 360 Air CO 365 kw 2,71 17,4 l/s 96 4.600 x 2.550 x 2.200 SyScrew 410 Air CO 413 kw 2,73 19,7 l/s 97 4.600 x 2.550 x 2.200 SyScrew 450 Air CO 445 kw 2,65 21, l/s 97 4.600 x 2.550 x 2.200 SyScrew 480 Air CO 480 kw 2,72 22,9 l/s 97 4.600 x 2.550 x 2.200 SyScrew 500 Air CO 505 kw 2,74 24,1 l/s 97 4.600 x 2.550 x 2.200 SyScrew 540 Air CO 540 kw 2,72 25,8 l/s 98 5.700 x 2.550 x 2.200 SyScrew 580 Air CO 575 kw 2,7 27,4 l/s 98 6.700 x 2.550 x 2.200 SyScrew 650 Air CO 652 kw 2,75 31,1 l/s 99 6.700 x 2.550 x 2.200 SyScrew 720 Air CO 713 kw 2,81 34,1 l/s 99 6.700 x 2.550 x 2.200 SyScrew 800 Air CO 794 kw 2,88 37,9 l/s 99 6.700 x 2.550 x 2.200 SyScrew 850 Air CO 851 kw 2,85 40,6 l/s 100 8.800 x 2.550 x 2.200 SyScrew 910 Air CO 909 kw 2,84 43,4 l/s 100 8.800 x 2.550 x 2.200 SyScrew 970 Air CO 971 kw 2,85 46,3 l/s 100 8.800 x 2.550 x 2.200 SyScrew 1000 Air CO 1.008 kw 3 48,1 l/s 100 8.800 x 2.550 x 2.200 SyScrew 1070 Air CO 1.071 kw 2,88 51,1 l/s 100 9.900 x 2.550 x 2.200 SyScrew 1130 Air CO 1.132 kw 2,89 54,1 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1170 Air CO 1.172 kw 2,85 55,9 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1200 Air CO 1.218 kw 2,82 58,2 l/s 101 10.900 x 2.550 x 2.200 SyScrew 1300 Air CO 1.316 kw 2,82 62,8 l/s 102 12.000 x 2.550 x 2.200
Air cooled Chiller & Heat Pump 15 Air Cooled Chiller & Heat Pump Product Range Capacity EER Flow rate Acoustic Power SLS 5204-8404 HE SLS 5204 HE 1.142 kw 3,50 54,5 l/s 102 SLS 5604 HE 1.208 kw 3,50 57,7 l/s 102 SLS 6004 HE 1.292,80 kw 3,40 61,7 l/s 103 SLS 6404 HE 1.406,40 kw 3,40 67,2 l/s 103 SLS 6804 HE 1.482,20 kw 3,20 70,8 l/s 103 SLS 7204 HE 1.557,90 kw 3,00 74,4 l/s 103 SLS 7804 HE 1.637,20 kw 3,00 78,2 l/s 103 SLS 8404 HE 1.686,90 kw 2,90 80,6 l/s 103 Size (LxHxP) 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 12.000 x 2.550 x 2.200 Selection guide Air Cooled Heat Pump Chiller Range Capacity COP Flow rate Acoustic Power Mini SysAqua DCI Size (LxHxP) Mini SysAqua DCI 5 5 kw 3,24 0,24 l/s 58 990 x 966 x 354 Mini SysAqua DCI 7 7 kw 3,20 0,33 l/s 58 990 x 966 x 354 Mini SysAqua DCI 10 10 kw 3,39 0,48 l/s 59 990 x 1327 x 354 Mini SysAqua DCI 12 11.2 kw 3,31 0,53 l/s 59 990 x 1327 x 354 Mini SysAqua DCI 14 12.5 kw 3,25 0,60 l/s 60 990 x 1327 x 354 Mini SysAqua DCI 16 14.5 kw 3,30 0,69 l/s 60 990 x 1327 x 354 SyScroll 20-30 Air EVO HP SyScroll 20 Air EVO HP SyScroll 30 Air EVO HP 20,4 kw 3,17 0,975 l/s 74 26,1 kw 3,1 1,247 l/s 75 1.477 x 1.615 x 539 1.477 x 1.615 x 539 SyScroll 20-35 Air HP SysAqua H SyScroll 20 Air HP 20,9 kw 3,12 0,99 l/s 73 1.477 x 1.615 x 539 SyScroll 25 Air HP 24,5 kw 3,19 1,17 l/s 74 1.477 x 1.615 x 539 SyScroll 30 Air HP 28,4 kw 3,26 1,35 l/s 74 1.477 x 1.615 x 539 SyScroll 35 Air HP 35 kw 3,24 1,67 l/s 75 1.477 x 1.615 x 539 SysAqua 25 H 26,9 kw 2,91 1,28 l/s 75 1.000 x 1.983 x 1.000 SysAqua 30 H 29,7 kw 3,02 1,41 l/s 75 1.000 x 1.983 x 1.000 SysAqua 35 H 37,3 kw 2,82 1,78 l/s 76 1.000 x 1.983 x 1.000 SysAqua 40 H 41,6 kw 3,04 1,98 l/s 76 1.000 x 1.983 x 1.000
16 Air cooled Chiller & Heat Pump Selection guide Air Cooled Heat Pump Product Range Capacity COP Flow rate Acoustic Power SyScroll 40-75 Air HP SysAqua H SyScroll 85-135 Air HP AQVH 85-140 SyScroll 140-360 Air Evo HP SyScroll 40 Air HP SyScroll 45 Air HP SyScroll 50 Air HP SyScroll 60 Air HP SyScroll 65 Air HP SyScroll 75 Air HP 39,2 kw 2,95 1,74 l/s 80 43,7 kw 3,01 1,95 l/s 81 51,7 kw 3,17 2,27 l/s 81 58 kw 2,72 2,67 l/s 85 69,1 kw 3 3,02 l/s 86 76,3 kw 2,84 3,37 l/s 86 Size (LxHxP) 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 1.750 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 2.200 x 1.580 x 1.100 SysAqua 45 H 50 kw 2,80 2,38 l/s 79 2.180 x 1.986 x 1.160 SysAqua 55 H 58,4 kw 2,86 2,79 l/s 79 2.180 x 1.986 x 1.160 SysAqua 65 H 69,6 kw 3,06 3,32 l/s 79 2.180 x 1.986 x 1.160 SysAqua 75 H 75,9 kw 3,12 3,62 l/s 79 2.180 x 1.986 x 1.160 SysAqua 90 H 88 kw 2,62 4,20 l/s 82 2.180 x 2.286 x 1.160 SysAqua 105 H 101 kw 2,63 4,82 l/s 82 2.180 x 2.286 x 1.160 SysAqua 125 H 119 kw 2,62 5,68 l/s 82 2.180 x 2.286 x 1.160 SyScroll 85 Air HP 85 kw 3,14 3,77 l/s 84 3.000 x 2.250 x 1.100 SyScroll 95 Air HP 96 kw 3,12 4,16 l/s 84 3.000 x 2.250 x 1.100 SyScroll 105 Air HP 107 kw 2,82 4,69 l/s 88 3.000 x 2.250 x 1.100 SyScroll 120 Air HP 120 kw 2,82 5,44 l/s 88 3.500 x 2.250 x 1.100 SyScroll 135 Air HP 132,6 kw 2,81 5,97 l/s 88 3.500 x 2.250 x 1.100 AQVH 85 87 kw 3,39 3,87 l/s 85 2.555 x 2.185 x 1.095 AQVH 95 100,4 kw 3,23 4,30 l/s 85 2.555 x 2.185 x 1.095 AQVH 105 108,3 kw 3,29 4,73 l/s 85 2.555 x 2.185 x 1.095 AQVH 115 116,4 kw 3,26 5,11 l/s 85 2.555 x 2.185 x 1.095 AQVH 125 131,5 kw 3,13 5,55 l/s 89 3.155 x 2.185 x 1.095 AQVH 140 143,6 kw 3,14 6,19 l/s 89 3.155 x 2.185 x 1.095 SyScroll 140 Air Evo HP SyScroll 170 Air Evo HP SyScroll 200 Air Evo HP SyScroll 230 Air Evo HP SyScroll 260 Air Evo HP SyScroll 280 Air Evo HP SyScroll 300 Air Evo HP SyScroll 330 Air Evo HP SyScroll 360 Air Evo HP 144,9 kw 3,23 6,8 l/s 90 165,7 kw 3,21 7,88 l/s 90 200,1 kw 3,22 9,52 l/s 92 229 kw 3,23 10,91 l/s 92 262,3 kw 3,21 12,50 l/s 93 279,6 kw 3,2 13,30 l/s 93 305,6 kw 3,22 14,55 l/s 94 327,2 kw 3,21 15,58 l/s 95 361,4 kw 3,21 17,22 l/s 95 4.000 x 2.600 x 1.100 4.000 x 2.600 x 1.100 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 3.500 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 4.550 x 2.600 x 2.150 132,1 kw
Air cooled Chiller & Heat Pump 17 Air Cooled Chiller & Heat Pump Product Range Capacity COP Flow rate Acoustic Power VLH 604-1204 SyScroll 240-660 Air HP AQWH 1404-2406 VLH 604 169,8 kw 2,93 8,11 l/s 93 VLH 704 200,1 kw 2,97 9,56 l/s 93 VLH 804 223,2 kw 3,17 10,66 l/s 93 VLH 904 254,7 kw 3,2 12,17 l/s 94 VLH 1004 270,8 kw 3,09 12,94 l/s 94 VLH 1104 302,1 kw 3,02 14,43 l/s 95 VLH 1204 337,4 kw 3,00 16,12 l/s 95 Size (LxHxP) 3.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 4.300 x 2.300 x 1.100 SyScroll 240 Air HP 255,9 kw 2,76 12,16 l/s 93 3.500 x 2.600 x 2.150 SyScroll 270 Air HP 289,1 kw 2,71 13,72 l/s 93 3.500 x 2.600 x 2.150 SyScroll 290 Air HP 313,3 kw 2,68 14,86 l/s 94 3.500 x 2.600 x 2.150 SyScroll 320 Air HP 333 kw 2,84 15,86 l/s 94 3.500 x 2.600 x 2.150 SyScroll 360 Air HP 382,4 kw 2,81 18,19 l/s 94 4.550 x 2.600 x 2.150 SyScroll 420 Air HP 444 kw 2,78 21,11 l/s 95 4.550 x 2.600 x 2.150 SyScroll 470 Air HP 491,5 kw 2,88 23,38 l/s 95 5.600 x 2.600 x 2.150 SyScroll 540 Air HP SyScroll 590 Air HP SyScroll 660 Air HP 556,4 kw 605 kw 679,1 kw 2,91 26,47 l/s 96 2,89 28,77 l/s 96 2,94 32,27 l/s 97 AQWH 1404 420 kw 3,17 20,06 l/s 97 AQWH 1604 470,1 kw 3,21 22,46 l/s 97 AQWH 1806 548,3 kw 3,18 26,19 l/s 98 AQWH 2106 627,2 kw 3,23 29,96 l/s 98 AQWH 2406 702 kw 3,18 33,54 l/s 98 5.600 x 2.600 x 2.150 6.650 x 2.600 x 2.150 6.650 x 2.600 x 2.150 4.000 x 2.550 x 2.200 4.000 x 2.550 x 2.200 5.000 x 2.550 x 2.200 6.000 x 2.550 x 2.200 6.000 x 2.550 x 2.200
18 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 20-35 Air CO 20-33 kw Plate 410A Air cooled Scroll Technical feature 4 sizes Cooling capacity from 20,8 to 33,7 kw One refrigerant circuit One scroll compressor New control Operating low water content in the plant Pump as standard Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coil grilles Coils treatment Desuperheater Electronic expansion valve Fan speed control (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water differential pressure switch (standard) Water filter (standard) Water flow switch SyScroll 20-35 Air CO - Cooling Operation OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Water+ Glycol+EEV Water -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) Operating limit (to be confirmed following selection software issue) SyScroll 20-35 Air CO 20 25 30 35 Min - Max Leaving water temperature * C from -8 to +18 T water K 3-7 Air temperature C Refer to below graphich * Below 5 C, glycol and electronic expansion valve is required. Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kw of cooling capacity.
Caratteristiche tecniche AQL 20 35 Technical feature Air cooled Chiller & Heat Pump 19 Air Cooled Chiller & Heat Pump SyScroll 20-35 Air CO 20 25 30 35 Cooling capacity 1 kw 20,8 24,4 28,2 33,7 Power input 1 kw 6,67 7,41 8,97 11,5 EER 100% 1 3,12 3,29 3,14 2,93 Energy Efficiency Class A A A B ESEER 3,56 3,77 3,70 3,44 Part load steps % 0-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 1 Scroll Crankcase heater W 70 90 90 90 Internal heat exchanger Qty 1 Plate exchanger AISI 316 Water flow l/s 0,97 1,14 1,32 1,59 Available Static Pressure kpa 169 152 144 114 Antifreeze heater W 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 1 1/4 Water drain connection inch ⅜ Fan Qty 2 Axial Air flow m 3 /h 10.957 10.425 10.425 9.919 Power input kw 0,54 0,54 0,54 0,55 Pump Qty 1 Power input kw 0,57 0,60 0,63 0,65 Weight Shipping kg 254 285 289 304 Operating kg 248 279 283 298 Dimensions Lenght mm 1.477 1.477 1.477 1.477 Width mm 539 539 539 539 Height mm 1.615 1.615 1.615 1.615 Acoustical data Sound power level 3 db(a) 73 74 74 75 Sound pressure level at 10 m 4 db(a) 41 42 42 43 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
20 Air cooled Chiller & Heat Pump Air Cooled Chiller SysAqua 25-40 L 25-37 kw Plate 410A Air cooled Scroll Technical feature 4 sizes Cooling capacity from 26.6 to 39.3 kw Refrigerant R410A EER up to 3.09 ESSEER up to 4.07 Main function Available with one cooling circuit Tandem scroll per refrigerant circuit Extented operating limits STD operating up to +7 C external Available versions Low sound level Standard High temperature operation up to 50 C (STD) Return or leaving water temperature control With Hydraulic kit 1 pump STD Product Advantages Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 lt/kw Low footprint Easy maintenance Low water pressure drop Set point compensation (standard) Night mode (extra low sound level) (standard) ON OFF Remote Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Closed cabinet with inside the thermodynamic and hydraulic parts Main accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-10 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete hydraulic kit 1 pump medium pressure Standard Rubber antivibration pad Water level pressure switch Water tank 100 l High pressure fan Operating limit (to be confirmed following selection software issue) SysAqua 25-40 L Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External air temperature (Maximum) External air temperature (Minimum) +5 C / +18 C +2 C +50 C -10 C
Technical feature Air cooled Chiller & Heat Pump 21 Air Cooled Chiller & Heat Pump SysAqua 25-40 L 25 30 35 40 Cooling Capacity kw 26,6 28,3 37,6 39,3 Power input kw 8,6 9,34 13,49 13,6 Total EER 100% ** 3,09 3,03 2,97 2,88 ESEER ** 3,97 3,96 4,07 3,90 Energy Efficiency Class B B B C Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Nominal current A 15,1 16,3 24 24 Maximum operating current A 18,2 21 29,6 30 Inrush current A 61 75 115 118 Refrigerant HFC 410A Number refrigerant circuits 1 1 1 1 Compressor Quantity 2 2 2 2 Scroll Scroll Scroll Scroll N capactity steps % 0/50/100 0/50/100 0/50/100 0/50/100 Crankcase heater W 40 70 70 70 Evaporator Qty 1 1 1 1 Plate Plate Plate Plate Water flow rate m³/h 4,3 4,6 6,1 6,3 Water pressure drop kpa 37 22 37 37 Water volume l 1,78 2,55 2,55 2,55 Antifreeze heater W 30 30 30 30 Coil Qty 1 1 1 1 Total coil face area per coil m 2 2,4 2,4 2,8 2,8 Fan motors Qty 1 1 1 1 Air flow m³/h 13.000 13.000 16.000 16.000 Speed tr/mn 900 900 650 650 Power input (unitary) W 940 940 930 930 Pump Qty Option 1 or 2 Pumps Power input Option 1 or 2 Pumps Available static pressure Option 1 or 2 Pumps Hydraulic connexion Male Gas Threaded Inlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Outlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Dimensions Length mm 1.000 1.000 1.000 1.000 Width mm 1.000 1.000 1.000 1.000 Height mm 1.983 1.983 1.983 1.983 Weight Operating kg 300 330 340 340 Acoustical data Sound power level * db(a) 75 75 76 76 * 0 Following Eurovent standard. ** 0Following Eurovent 14511.
22 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 40-75 Air CO 41-77 kw Plate 410A Air cooled Scroll Technical feature 6 sizes Cooling capacity from 40,8 to 76,7 kw 3 versions: STD (standard version) HT ( High Temperature) HPF (High Pressure Fans) 2 Low Noise versions: Standard version (STD) Super Low Noise version (S) One refrigerant circuit 2 scroll compressors (one tandem) Operating low water content in the plant Brine version for process application Accessories and options Automatic circuit breaker Coils treatments Coils grilles (standard) Compressors jackets (standard S) Electronic expansion valves Overload protection for compressors Sequencer for up to 4 chillers installation Desuperheater Fan speed control ( down to -18 C) Hydrokit with 1 or 2 pumps with or without buffer tank Hydrometer (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter (standard) Water differential switch (standard) Water flow switch (standard)
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 23 Air Cooled Chiller & Heat Pump SyScroll 40-75 Air CO 40 45 50 60 65 75 Min - Max Leaving water temperature * C from -8 to +18 Water T K 3-7 Air Temperature C Refers to following graphics * Below 5 C, glycol and electronic expansion valve are required. Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kw of output. BLN Version S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 - 10 Water + Glycol + EEV Water Water+ Glycol + EEV + FSC Water+ FSC -9-8 -7-6 -5-4 -3-2-1 0 1 2 3 4 5 6 7 8 9 1011121314151617181 920 LWT ( C) OAT ( C) 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 - 10 Water+ Glycol + EEV Water Water+ Glycol + EEV + FSC Water+ FSC -9-8 -7-6 -5-4 -3-2 -1 0 1 2 3 4 5 6 7 8 9 10 11121314151617181920 LWT ( C) HT Version 55 50 45 40 35 30 25 20 15 10 Water+ Glycol + EEV Water 5 0-5 -10-15 -20-25 - 10-9 -8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 1011 12131415161718192 0 T OAT ( C) 40-50 60-75 LWT ( C)
24 Air cooled Chiller & Heat Pump Technical feature SyScroll 40-75 Air CO (STD-HPF-HT) 40 45 50 60 65 75 Cooling capacity 1 kw 40,8 44,8 51,9 60,9 68,9 76,7 Power input 1 kw 14,0 16,2 18,6 20,5 23,5 27,9 EER 1 2,91 2,77 2,79 2,97 2,93 2,75 Energy Efficiency Class B C C B B C ESEER 4,08 3,87 3,89 4,01 4,07 3,73 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Diretto Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 2 2 2 2 2 2 Scroll Cranckcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.884 7.572 8.774 10.317 11.680 13.032 Antifreeze heater W 35 35 35 35 35 35 Connection type Male GAS threaded Inlet/outlet diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 14.000 14.000 13.200 21.100 21.100 21.100 Speed rpm/min 680 680 680 900 900 900 Power input kw 0,98 0,98 0,98 2,00 2,00 2,00 Power input * kw 2,67 2,67 2,67 2,67 2,67 2,67 Available static pressure * Pa from 0 to 120 Weight Shipping kg 403 411 436 476 483 488 Operating kg 413 421 446 489 496 502 Dimensions Lenght mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 78 79 79 83 84 84 Sound pressure level at 10 m 3 db(a) 47 47 47 52 52 52 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * HPF / HT versions with EC fan motor.
Caratteristiche Technical feature tecniche AQL 20 35 Air cooled Chiller & Heat Pump 25 Air Cooled Chiller & Heat Pump SyScroll 40-75 Air CO S 40 45 50 60 65 75 Cooling capacity 1 kw 39,4 43,1 49,6 59,0 64,0 73,7 Power input 1 kw 14,3 16,6 19,4 20,7 23,6 28,7 EER 1 2,76 2,60 2,56 2,85 2,71 2,57 Energy Efficiency Class C D D C C D ESEER 3,87 3,62 3,58 3,85 3,77 3,50 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 2 2 2 2 2 2 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.656 7.293 8.376 9.976 10.853 12.522 Antifreeze heater W 35 35 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 11.000 11.000 10.300 16.000 16.000 16.000 Speed rpm/min 530 530 530 720 720 720 Power input kw 0,57 0,57 0,57 1,27 1,27 1,27 Weight Shipping kg 403 411 436 476 483 488 Operating kg 413 421 446 489 496 502 Dimensions Lenght mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 74 75 75 78 79 79 Sound pressure level at 10 m 3 db(a) 42 44 44 46 47 47 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
26 Air cooled Chiller & Heat Pump Air Cooled Chiller SysAqua 45-125 L 49.1-128 kw Plate 410A Air cooled Scroll Technical feature Cooling capacity from 49.1 to 128 kw 7 sizes Refrigerant: R410A EER up to 3.13 ESSEER up to 4.14 Main functions Available with one cooling circuit Tandem scroll per refrigerant circuit Extented operating limits STD operating up to +7 C external T Product Advantages Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 lt/kw Low footprint Easy maintenance Low water pressure drop Set point compensation (standard) Night mode (extra low sound level) std ON OFF Remote Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-10 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 2 pumps medium pressure Rubber antivibration pad Water level pressure switch Water tank 300lt High pressure fan Operating limit (to be confirmed following selection software issue) SysAqua 45-125 L Leaving water temperature (without glycol) Leaving water temperature (with glycol max 40%) External air temperature (Maximum) External air temperature (Minimum) +5 C / +18 C +2 C +50 C -10 C
Technical feature Air cooled Chiller & Heat Pump 27 Air Cooled Chiller & Heat Pump SysAqua 45-125 L 45 55 65 75 90 105 125 Cooling Capacity kw 49,1 56 69,1 75,1 96 111,5 128 Power input kw 16,9 19,67 22,1 24,3 34,36 38,06 46,4 Total EER 100% ** 2,91 2,85 3,13 3,1 2,79 2,93 2,76 ESEER ** 4,06 4,08 4,2 4,17 4,01 4,04 4,02 Energy Efficiency Class B C A A C B C Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Direct Direct Direct Nominal current A 30 35 42 47 62 69 84 Maximum operating current A 34 39 52 57 67 77 92 Inrush current A 126 134 195 201 250 300 330 Refrigerant HFC 410A Number refrigerant circuits 1 1 1 1 1 1 1 Compressor Quantity cooling cicuits 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll N capactity steps % 0/50/100 0/45/ 55/100 0/40/ 60/100 0/45/ 55/100 0/45/ 55/100 0/40/ 60/100 0/33/ 67/100 Crankcrase heater W 2 * 90 2 * 90 2 * 90 2 * 90 140 90/140 90/140 Evaporator Qty 1 1 1 1 1 1 1 Plate Plate Plate Plate Plate Plate Plate Water flow rate m 3 /h 8 9,1 11,3 12,3 15,7 18,2 20,9 Water pressure drop kpa 27 35 28 33 26 34 45 Water volume l 4,1 4,1 6,1 6,1 10,8 10,8 10,8 Antifreeze heater W 30 30 2 * 30 2 * 30 2 * 30 2 * 30 2 * 30 Coil Qty 1 1 2 2 2 2 2 Total coil face area per coil m 2 4,2 4,2 5,55 5,55 6,4 6,4 6,4 Fan motors Quantity 1 1 2 2 2 2 2 Air flow m 3 /h 22.500 22.500 30.000 30.000 42.000 42.000 42.000 Power input (unitary) W 2.100 2.100 930 930 2.100 2.100 2.100 Pumps Qty Option 1 ou 2 pumps Power input kw Option 1 ou 2 pumps Available static pressure Kpa Option 1 ou 2 pumps Hydraulic Connection Male GAS Threaded Inlet diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Outlet diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Dimensions Length mm 2.180 2.180 2.180 2.180 2.180 2.180 2.180 Width mm 1.160 1.160 1.160 1.160 1.160 1.160 1.160 Height mm 1.986 1.986 1.986 1.986 2.286 2.286 2.286 Weight Operating kg 490 490 560 560 870 980 1.000 Acoustical data Sound power level * db(a) 79 79 79 79 82 82 82 * Following Eurovent standard. ** Following Eurovent 14511.
28 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 85-135 Air CO 84-132 kw Plate 410A Air cooled Scroll Technical feature 5 sizes Cooling capacity from 84,2 to 132,1 kw 3 Versions: STD (Standard version) HT (High Temperature version) HPF (High Pressure Fans version) 2 acoustic versions: Standard version (STD) Super Low Noise version (S) One refrigerant circuit 2 Scroll compressors (Tandem) Microchannel coils Microprocessor control Electronic expansion valve as standard E-Coating coil treatment as standard Brine version for process application Accessories and options Hydrokit with 1 or 2 pumps with or without buffer tank Desuperheater Unit protection grilles Sofstart BMS interface Overload protection for compressors Automatic circuit breaker Water flow switch (standard) Mechanical gauges Fan speed control Water pressure switch Water filter Power factor corrector capacitors Compressors acoustic box (standard) Sequence phases control (standard) Compressors jackets
Operating Limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 29 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air CO Leaving water temperature Air temperature External static pressure Min 85-135 Water С +6 +18 Water with glycol + electonic expansion valve * С -8 +5 T Water К 3 7 BLN С +10 +45 S С -14 +42 HT С -16 +47 Standard fans Pa 0 High pressure fans (HPF) Pa < 120 Max * For operation below 0 C contact sales office. STD Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 1012 1416 18 LWT ( C) HT Version OAT ( C) 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C)
30 Air cooled Chiller & Heat Pump Technical feature SyScroll 85-135 Air CO 85 95 105 120 135 Cooling capacity 1 kw 84,2 93,2 104,6 118,6 132,1 Power input 1 kw 27,2 31,5 37,7 42,0 47,6 EER 1 3,09 2,96 2,77 2,82 2,78 Energy efficiency class B C C C C ESEER 3,94 4,35 4,00 4,01 4,03 Part load steps 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 14,5 16,0 18,0 20,4 22,7 Water pressure drop kpa 26 32 28 22 19 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil m 2 2,4 3,1 Fan Qty 2 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 2 db(a) 84 84 88 88 88 Sound pressure level 3 db(a) 52 52 56 56 56 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 31 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air CO S 85 95 105 120 135 Cooling capacity 1 kw 81,1 89,3 101,4 113,5 126,0 Power input 1 kw 28,0 32,8 38,6 43,0 49,6 EER 1 2,90 2,72 2,63 2,64 2,54 Energy efficiency class C C D D D ESEER 3,91 4,32 3,98 4,03 4,00 Part load steps % 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 13,9 15,4 17,4 19,5 21,7 Water pressure drop kpa 23 28 25 20 17 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil m 2 2,4 3,1 Fans Qty 2 Air flow rate m 3 /h 25.000 34.000 36.000 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 2 db(a) 82 82 85 85 85 Sound pressure level 3 db(a) 50 50 53 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
32 Air cooled Chiller & Heat Pump Air Cooled Chiller AQVL 85-140 83-137 kw Plate 410A Air cooled Scroll Technical feature 6 sizes Cooling capacity from 83,3 to 136,5 kw 4 versions: STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions: Standard version (STD), Extra Low Noise version (ELN) Two refrigerant circuits Scroll compressors Microprocessor control Low operating water content in the plant Electronic expansion valve as standard Brine version for process application E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets as standard on ELN Desuperheater & Totaly heat recovery Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Pressure switch Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure & Water flow switch (standard) Water filter Operating limit (to be confirmed following selection software issue) AQVL 85-140 Min Max Leaving water temperature Air temperature External static pressure 55 50 45 40 35 30 25 20 15 10 Water+ Glycol + EEV Water 5 0-5 -10-15 -20-25 - 10-9 -8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 1011 12131415161718192 0 OAT ( C) LWT ( C) 85-115 125-140 Water С +5 +18 Water with glycol С 0 +18 Water with glycol (Brine version) C -8 +18 BLN С +5 +47 ELN С -18 +44 HSE/HT С -18 Standard fans Pa 0 High Pressure Fans (HPF) Pa < 120 +50 (85-115) +47 (125-140)
Technical feature Air cooled Chiller & Heat Pump 33 Air Cooled Chiller & Heat Pump AQVL 85-140 BLN 85 95 105 115 125 140 Cooling capacity 1 kw 83,3 93,3 102,6 110,5 121,6 136,5 Power input 1 kw 27,1 31,0 33,6 36,6 40,9 46,1 EER 1 3,08 3,01 3,05 3,02 2,97 2,96 Energy Efficiency class B B B B B B ESEER 4,16 4,15 4,07 4,12 3,95 4,01 EER HSE 1 3,19 3,09 3,13 3,10 3,05 3,03 Energy Efficiency class A B A A B B ESEER HSE 4,06 4,12 4,23 4,19 3,96 4,08 Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow m 3 /h 14.377 16.116 17.681 19.023 21.033 23.588 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil mm 2,4 2,4 2,4 2,4 3,1 3,1 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 34.000 34.000 33.200 32.400 44.000 42.800 Speed rpm/min 690 690 690 690 900 900 Power input kw 2,1 2,1 2,1 2,1 3,4 3,4 Power input HSE kw 1,2 1,2 1,2 1,2 2,4 2,4 Power input HPF kw 3,6 3,6 3,6 3,6 4,6 4,6 Weight Shipping kg 1.033 1.047 1.084 1.116 1.151 1.230 Operating kg 1.058 1.072 1.111 1.143 1.183 1.262 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 84 84 84 84 88 88 Sound pressure level 3 db(a) 52 52 52 52 56 56 Sound power level HPF 2 db(a) 92 92 92 92 95 95 Sound pressure level HPF 3 db(a) 60 60 60 60 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
34 Air cooled Chiller & Heat Pump Technical feature AQVL 85-140 ELN 85 95 105 115 125 140 Cooling capacity 1 kw 80,6 89,9 98,3 105,6 119,6 133,5 Power input 1 kw 26,1 30,2 32,8 35,7 39,9 45,1 EER 1 2,87 2,75 2,77 2,73 2,90 2,86 Energy efficiency class C C C C B C ESEER 3,91 3,78 3,81 3,67 3,92 3,93 EER HSE 1 3,00 2,87 2,87 2,81 2,96 2,91 Energy efficiency class B C C C B B ESEER HSE 3,91 3,87 3,87 3,79 3,99 3,94 Part load steps % 0-25-50-75-10 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 13.906 15.532 16.971 18.204 20.550 22.988 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 3,1 3,1 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 25.200 25.200 24.600 24.000 36.500 35.000 Speed rpm/min 500 500 500 500 690 690 Power input kw 1,8 1,8 1,8 1,8 2,1 2,1 Power input HSE kw 0,6 0,6 0,6 0,6 1,2 1,2 Weight Shipping kg 1.063 1.077 1.114 1.146 1.181 1.260 Operating kg 1.088 1.102 1.141 1.173 1.213 1.292 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 82 82 82 82 86 86 Sound pressure level 3 db(a) 50 50 50 50 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 35 Air Cooled Chiller & Heat Pump AQVL 85-140 HT 85 95 105 115 125 140 Cooling capacity 1 kw 86,2 97,0 106,9 115,3 124,6 139,6 Power input 2 kw 23,2 26,6 28,9 31,4 36,1 40,9 EER 3,10 3,10 3,19 3,21 3,06 3,07 ESEER 4,34 4,34 4,46 4,49 4,29 4,30 Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 14.835 16.680 18.381 19.838 21.427 24.014 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 3,1 3,1 Fans Qty 2 2 2 2 2 2 Air flow m 3 /h 49.700 49.700 48.950 48.200 52.200 50.700 Speed rpm/min 1.130 1.130 1.130 1.130 1.130 1.130 Power input kw 4,6 4,6 4,6 4,6 4,6 4,6 Weight Shipping kg 1.033 1.047 1.084 1.116 1.151 1.230 Operating kg 1.058 1.072 1.111 1.143 1.183 1.262 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 3 db(a) 95 95 95 95 95 95 Sound pressure level 4 db(a) 63 63 63 63 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
36 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 140-360 Air EVO CO 144-360 kw Plate Air cooled Scroll 410A ENERGY EFFICIENCY COOLING MODE 2014 Technical feature 9 sizes Cooling capacity from 144 to 360,7 kw Fans versions: STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans) Acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Brine version: Cooling only for process application LWT -10 C Two refrigerant circuits 4 Scroll compressors Electronic expansion valve Microchannel coils E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater and totaly heat recovery (TR version) Fan speed control (-14 C in cooling mode standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch Report to performance data
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 37 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air EVO CO 140 170 200 230 Min Max Min Max Min Max Min Max Water C +5 to +18 Liquid outlet Chilled Water with glycol temperature C -10 to +5 liquid Temperature spread K 3 to 7 Maximum operating pressure bar 6 - C +5 to +48 Air entering L C +0 to +46 temperature Ambient cooling S C -14 to +44 air EC-HT C -18 to +50 External Temperature spread Pa 0 static pressure High pressure fans Pa <120 Recommended system chilled water volume 1 l 420 510 600 690 Minimum capacity step % 25 25 21 19 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) SyScroll 140-360 Air EVO CO 260 280 300 330 360 Min Max Min Max Min Max Min Max Min Max Water C +5 to +18 High Liquid outlet Water with glycol pressure temperature C -10 to +5 fans Temperature spread K 3 to 7 Maximum operating pressure bar 6 - C +5 to +48 Air entering L C +0 to +46 temperature Ambient cooling S C -14 to +44 air EC-HT C -18 to +50 External Standard fans Pa 0 static pressure High pressure fans Pa <120 Recommended system chilled water volume 1 l 780 840 900 990 1080 Minimum capacity step % 17 16 24 23 25 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) * For Liquid outlet temperature <0 C provide Brine Version (available for CO; on request for HP). 1 Table shows minimum water / brine volume of system (about 3 lt/kw). 2 Voltage 400V +/- 10%. - version OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) S version OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) L version OAT ( C) OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol Water + Glycol Acqua + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) EC-HT version Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C)
38 Air cooled Chiller & Heat Pump Technical feature SyScroll 140-360 Air Evo CO (STD-EC-HPF) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 144,0 168,6 196,4 229,9 262,6 283,5 309,3 330,3 360,7 Input power 1 kw 44,7 54,2 62,0 73,9 83,4 90,3 98,5 103,9 116,0 EER 1 3,22 3,11 3,17 3,11 3,15 3,14 3,14 3,18 3,11 Energy efficiency class A A A A A A A A A ESEER 3,96 3,81 4,00 4,00 4,05 4,02 4,01 4,10 4,00 EER * 3,26 3,14 3,22 3,16 3,19 3,18 3,19 3,23 3,16 ESEER * 4,16 4,00 4,20 4,22 4,27 4,24 4,21 4,26 4,20 EER ** 3,03 2,96 2,95 2,93 2,96 2,96 2,95 2,98 2, 93 ESEER ** 3,81 3,63 3,84 3,84 3,93 3,86 3,85 4,02 3,84 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37-68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 24,9 29,1 33,9 39,7 45,3 48,9 53,4 57,0 62,2 Pressure drop kpa 27 37 40 35 35 41 30 34 41 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fans Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 900 900 900 900 900 900 900 900 900 Total airflow m 3 /h 68.400 68.400 112.500 112.500 135.000 135.000 157.500 180.000 180.000 Total input power kw 5,1 5,1 8,5 8,5 10,2 10,2 11,9 13,6 13,6 Total input power * kw 4,5 4,5 7,5 7,5 9,0 9,0 10,5 12,0 12,0 Total input power ** kw 7,8 7,8 13,0 13,0 15,6 15,6 18,2 20,8 20,8 External static pressure Pa 0 or 120 Pa ** Water Connections (Evaporator) Male GAS Threaded Inlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet Diameter / Outlet Diameter inch 1 /1 Weight Shipping kg 1.139 1.183 1.477 1.592 1.738 1.738 2.237 2.264 2.274 Operating kg 1.157 1.200 1.492 1.617 1.765 1.705 2.286 2.303 2.313 Additional weight EC-HPF versions kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 90 90 92 92 93 93 94 95 95 Sound pressure level 10 m 3 db(a) 58 58 60 60 61 61 62 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans. ** HPF Units with high static pressure fans.
Technical feature Air cooled Chiller & Heat Pump 39 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air Evo CO L (STD-EC) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 139,9 162,9 191,5 222,9 255,1 275,0 300,1 321,3 349,5 Input power 1 kw 45,0 54,9 61,4 74,3 83,6 91,1 99,0 103,7 116,5 EER 1 3,11 2,97 3,12 3,00 3,05 3,02 3,03 3,10 3,00 Energy efficiency class A B A B B B B A B ESEER 4,04 3,91 4,08 4,08 4,11 4,10 4,09 4,14 4,08 EER * 3,15 3,01 3,17 3,04 3,10 3,06 3,07 3,15 3,04 ESEER * 4,24 4,10 4,28 4,30 4,34 4,33 4,29 4,31 4,28 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37- 68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Number 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 24,1 28,1 33,1 38,5 44,0 47,5 51,8 55,4 60,3 Pressure drop kpa 26 35 38 33 33 38 28 32 38 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fans Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 700 700 700 700 700 700 700 700 700 Total airflow m 3 /h 55.000 55.000 92.500 92.500 111.000 111.000 129.500 148.000 148.000 Total input power kw 3,6 3,6 6,0 6,0 7,2 7,2 8,4 9,6 9,6 Water Connections (Evaporator) Male GAS Threaded Inlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet Diameter inch 1 1 1 1 1 1 1 1 1 Outlet Diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.139 1.183 1.477 1.592 1.738 1.738 2.237 2.264 2.274 Operating kg 1.157 1.200 1.492 1.617 1.765 1.765 2.286 2.303 2.313 Additional weight EC versions kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 85 85 87 87 88 88 89 90 90 Sound pressure level 10 m 3 db(a) 53 53 55 55 56 56 57 58 58 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans.
40 Air cooled Chiller & Heat Pump Technical feature SyScroll 140-360 Air Evo CO S (STD-EC) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 132,5 152,9 182,3 209,4 241,0 258,7 282,5 304,3 328,5 Input power 1 kw 47,0 57,5 63,3 78,7 88,0 96,2 104,6 108,7 123,5 EER 1 2,82 2,66 2,88 2,66 2,74 2,69 2,70 2,80 2,66 Energy efficiency class C D C C C D C C C ESEER 4,12 4,00 4,16 4,16 4,17 4,18 4,17 4,18 4,16 EER * 2,86 2,69 2,92 2,70 2,78 2,72 2,74 2,84 2,70 ESEER * 4,33 4,20 4,37 4,39 4,40 4,41 4,38 4,35 4,37 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37- 68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 22,9 26,4 31,5 36,1 41,6 44,6 48,7 52,5 56,7 Pressure drop kpa 23 31 35 29 29 34 25 29 34 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fans Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 550 550 550 550 550 550 550 550 550 Total airflow m 3 /h 44.000 44.000 72.500 72.500 87.000 87.000 101.500 116.000 116.000 Total input power kw 2,7 2,7 4,5 4,5 5,4 5,4 6,3 7,2 7,2 Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter inch 1 1 1 1 1 1 1 1 1 Outlet diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.144 1.188 1.482 1.597 1.743 1.743 2.242 2.269 2.279 Operating kg 1.162 1.205 1.497 1.622 1.770 1.770 2.291 2.308 2.318 Additional weight EC version kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 79 79 82 82 83 83 85 86 86 Sound pressure level 10 m 3 db(a) 47 47 50 50 51 51 53 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans.
Technical feature Air cooled Chiller & Heat Pump 41 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air Evo CO HT 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 145,3 170,2 197,9 232,0 264,7 286,0 312,0 332,9 363,8 Input power 2 kw 38,7 47,9 52,2 63,7 71,4 78,2 84,5 88,1 99,7 EER 3,09 3,02 3,00 2,99 3,01 3,02 3,01 3,03 2,99 Energy efficiency class B B B B B B B B B ESEER 3,88 3,72 3,92 3,92 3,99 3,94 3,93 4,06 3,92 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37- 68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 25,1 29,4 34,2 40,0 45,7 49,4 53,8 57,4 62,8 Pressure drop kpa 28 38 41 36 36 42 31 35 42 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fans Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Total airflow m 3 /h 80.500 80.500 132.500 132.500 159.000 159.000 185.500 212.000 212.000 Total input power kw 7,8 7,8 13,0 13,0 15,6 15,6 18,2 20,8 20,8 Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter inch 1 1 1 1 1 1 1 1 1 Outlet diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.169 1.213 1.527 1.642 1.798 1.798 2.307 2.344 2.354 Operating kg 1.187 1.230 1.542 1.667 1.825 1.825 2.356 2.383 2.393 Additional weight With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 3 db(a) 92 92 94 94 96 96 97 98 98 Sound pressure level 10 m 4 db(a) 60 60 62 62 64 64 65 66 66 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
42 Air cooled Chiller & Heat Pump Technical feature SyScroll 140-360 Air Evo TR 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 141,8 169,7 189,2 230,5 260,5 283,7 308,1 324,1 359,8 Input power 2 kw 39,9 47,9 55,3 64,0 73,2 78,9 86,0 91,6 101,1 EER 3,43 3,40 3,29 3,47 3,44 3,46 3,48 3,43 3,43 Heat recovery capacity 1 183,2 219,7 246,7 296,9 336,2 365,7 396,7 418,6 464,7 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37- 68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 24,5 29,3 32,7 39,8 45,0 49,0 53,2 55,9 62,1 Pressure drop kpa 26 38 37 35 34 41 30 33 41 Water volume 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Inlet/outlet water connection inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Recovery Condenser Qty 1 1 1 2 2 2 1 1 1 Plate Water flow m 3 /h 31,3 37,6 42,2 50,8 57,5 62,5 67,9 71,7 79,5 Pressure drop kpa 43 62 62 57 56 67 49 54 67 Water volume 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Inlet/outlet water connection inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Weight Shipping kg 1.331 1.375 1.875 2.008 2.227 2.227 2.844 2.937 2.937 Operating kg 1.342 1.386 1.885 2.028 2.250 2.250 2.876 2.969 2.969 Additional weight EC version kg 30 30 50 50 60 60 70 80 80 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 1 Data refers to 7 C leaving chilled water temperature and 45 C leaving condenser water temperature. 2 Input power (only compressors).
Air cooled Chiller & Heat Pump 43 Air Cooled Chiller & Heat Pump Keep it cool. With Systemair Air Conditioning system.
44 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScroll 240-660 Air CO 238-654 kw Plate 410A Air cooled Scroll Technical feature 10 sizes Cooling capacity from 238,1 to 654,2 kw 3 versions: STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Brine version: Cooling only for process application LWT -10 C Two refrigerant circuits 3/4/5/6 Scroll compressors Electronic expansion valve Microchannel coils E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard for S version) Desuperheater and totaly heat recovery (TR version) Hydrokit with 1 or 2 pumps with or without buffer tank Overload protection for compressors Mechanical gauges Pressostatic fan speed control (standard for S version) Power factor corrector capacitors Sequence phases control (standard) Softstart Unit protection grilles Water flow switch Water differential pressure switch (standard) Water filter
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 45 Air Cooled Chiller & Heat Pump SyScroll 240-360 Air CO 240 270 290 320 360 Min Max Min Max Min Max Min Max Min Max Water C +6 to +18 Liquid outlet Chilled Water with glycol temperature C -10 to +6 liquid Temperature spread K 3 to 7 Maximum operating pressure bar 6 - C +10 to +45 +10 to +45 +10 to +45 +10 to +45 +10 to +45 Air entering L C +7 to +43 +7 to +43 +7 to +43 +7 to +43 +7 to +43 temperature Ambient cooling S C -14 to +43-14 to +43-14 to +43-14 to +43-14 to +43 air HT-HPF C -18 to +47-18 to +47-18 to +47-18 to +47-18 to +47 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 960 1.080 1.160 1.280 1.080 Minimum capacity step % 31 33 30 27 23 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) SyScroll 420-660 Air CO 420 470 540 590 660 Min Max Min Max Min Max Min Max Min Max Water C +6 to +18 Liquid outlet Chilled Water with glycol temperature C -10 to +6 liquid Temperature spread K 3 to 7 Maximum operating pressure bar 6 - C +10 to +45 +10 to +45 +10 to +45 +10 to +45 +10 to +45 Air entering L C +7 to +43 +7 to +43 +7 to +43 +7 to +43 +7 to +43 temperature Ambient cooling S C -14 to +43-14 to +43-14 to +43-14 to +43-14 to +43 air HT-HPF C -18 to +47-18 to +47-18 to +47-18 to +47-18 to +47 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 1.260 1.128 1.296 1.180 1.320 Minimum capacity step % 25 24 20 14 17 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) * For Liquid outlet temperature <0 C provide Brine Version (available for CO; on request for HP). 1 Table shows minimum water / brine volume of system (about 3 lt/kw). 2 Voltage 400V +/- 10%. - version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) S version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) L version OAT ( C) OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 1416 18 LWT ( C) HT-HPF version Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C)
46 Air cooled Chiller & Heat Pump Technical feature SyScroll 240-660 Air CO (STD-EC-HPF) 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 238,1 267,4 287,4 316,1 362,0 414,2 469,6 533,7 588,9 654,2 Input power 1 kw 83,8 99,0 103,4 111,6 128,3 148,7 160,9 183,9 198,1 221,6 EER 1 2,84 2,70 2,78 2,83 2,82 2,78 2,92 2,90 2,97 2,95 Energy efficiency class C C C C C C B B B B ESEER 3,75 3,62 3,80 3,89 3,93 3,95 4,01 3,87 4,01 3,98 EER * 2,87 2,73 2,81 2,86 2,85 2,82 2,95 2,93 3,01 2,99 ESEER * 3,84 3,69 3,89 3,98 4,02 4,04 4,10 3,95 4,09 4,06 EER ** 2,70 2,58 2,64 2,70 2,69 2,66 2,78 2,77 2,83 2,82 ESEER ** 3,40 3,33 3,44 3,53 3,55 3,57 3,64 3,54 3,66 3,73 Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 Plate Water flow m 3 /h 41,1 46,2 49,7 54,5 62,5 71,6 81,1 92,2 101,7 113,1 Pressure drop kpa 50 62 72 35 45 58 44 57 54 66 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze Heater W 130 130 130 130 130 130 130 130 130 130 Air cooled condenser Qty of coils 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty of fans 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 900 900 900 900 900 900 900 900 900 900 Total airflow m 3 /h 112.500 112.500 135.000 135.000 157.500 180.000 202.500 225.000 247.500 270.000 Total input power kw 8,5 8,5 10,2 10,2 11,9 13,6 15,3 17,0 18,7 20,4 Total input power * kw 7,5 7,5 9,0 9,0 10,5 12,0 13,5 15,0 16,5 18,0 Total input power ** kw 13,0 13,0 15,6 15,6 18,2 20,8 23,4 26,0 28,6 31,2 External static pressure Pa 0 or 120 Pa ** Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.772 1.773 1.865 1.921 2.306 2.417 2.897 3.009 3.412 3.509 Operating kg 1.786 1.787 1.879 1.945 2.330 2.441 2.934 3.047 3.456 3.553 Additional weight HT-HPF versions kg 50 50 60 60 70 80 90 100 110 120 With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 93 93 94 94 94 95 95 96 96 97 Sound pressure level 10 m 3 db(a) 61 61 62 62 62 63 63 64 64 64 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * Unità alta temperatura (HT) con ventilatori inverter. ** HPF Units with high static pressure fans.
Technical feature Air cooled Chiller & Heat Pump 47 Air Cooled Chiller & Heat Pump SyScroll 240-660 Air CO L 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 230,0 256,9 277,6 303,8 348,5 398,6 451,7 513,1 566,5 628,8 Input power 1 kw 85,1 101,5 104,9 113,9 131,1 151,6 164,2 187,5 202,2 225,9 EER 1 2,70 2,53 2,65 2,67 2,66 2,63 2,75 2,74 2,80 2,78 Energy efficiency class C D D D D D C C C C ESEER 3,83 3,60 3,73 3,82 3,99 4,03 4,07 3,89 4,01 3,99 Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 Plate Water flow m 3 /h 39,7 44,4 48,0 52,4 60,2 68,9 78,0 88,6 97,8 108,6 Water pressure drop kpa 47 58 67 32 42 54 41 52 50 61 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze heater W 130 130 130 130 130 130 130 130 130 130 Air cooled condenser Qty 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 700 700 700 700 700 700 700 700 700 700 Total airflow m 3 /h 92.500 92.500 111.000 111.000 129.500 148.000 166.500 185.000 203.500 222.000 Total input power kw 6,0 6,0 7,2 7,2 8,4 9,6 10,8 12,0 13,2 14,4 Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.772 1.773 1.865 1.921 2.306 2.417 2.897 3.009 3.412 3.509 Operating kg 1.786 1.787 1.879 1.945 2.330 2.441 2.934 3.047 3.456 3.553 Additional weight With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 88 88 89 89 90 91 91 91 92 92 Sound pressure level 10 m 3 db(a) 56 56 57 57 58 59 59 59 59 59 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
48 Air cooled Chiller & Heat Pump Technical feature SyScroll 240-660 Air CO S 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 214,4 236,9 259,0 280,6 323,0 368,9 418,3 474,2 524,1 580,9 Input power 1 kw 91,0 109,9 112,0 122,6 141,3 162,9 176,6 201,5 217,3 242,5 EER 1 2,36 2,16 2,31 2,29 2,29 2,26 2,37 2,35 2,41 2,40 Energy efficiency class E F E F F F E E E E ESEER 3,61 3,42 3,57 3,59 3,82 3,88 3,90 3,68 3,99 3,99 Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 Plate Water flow m 3 /h 37,0 40,9 44,8 48,4 55,7 63,7 72,2 81,9 90,5 100,3 Water pressure drop kpa 41 49 59 28 36 47 35 45 43 53 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze heater W 130 130 130 130 130 130 130,0 130 130 130 Air cooled condenser Qty 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 550 550 550 550 550 550 550 550 550 550 Total airflow m 3 /h 72.500 72.500 87.000 87.000 101.500 116.000 130.500 145.000 159.500 174.000 Total input power kw 4,5 4,5 5,4 5,4 6,3 7,2 8,1 9,0 9,9 10,8 Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.772 1.773 1.865 1.921 2.306 2.417 2.897 3.009 3.412 3.509 Operating kg 1.786 1.787 1.879 1.945 2.330 2.441 2.934 3.047 3.456 3.553 Additional weight With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 2 db(a) 85 86 87 87 88 88 89 89 90 90 Sound pressure level 10 m 3 db(a) 53 54 55 55 56 56 57 57 57 57 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 49 Air Cooled Chiller & Heat Pump SyScroll 240-660 Air TR 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 233,7 266,1 280,1 321,2 365,4 413,9 474,9 535,1 596,3 659,2 Input power 1 kw 85,5 100,5 105,2 113,9 131,3 151,7 169,1 189,9 207,3 228,3 EER 1 2,93 2,83 2,74 3,17 3,10 2,97 3,23 3,12 3,29 3,21 Total heat rejection 1 313,4 360,3 382,5 422,6 483,2 553,3 622,0 706,5 777,7 864,9 Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 Plate Water flow m 3 /h 40,4 46,0 48,5 55,4 63,1 71,5 82,0 92,4 103,0 113,9 Water pressure drop kpa 48 62 68 36 46 58 45 57 55 67 Water volume l 14 14 14 24 24 24 32 32 39 39 Inlet/outlet water connection inch 3 3 3 3 4 4 4 4 5 5 Recovery condenser Qty 1 Plate Water flow m 3 /h 53,5 61,4 65,2 72,3 82,6 94,5 106,4 120,7 132,9 147,6 Water pressure drop kpa 83 108 121 59 77 99 74 95 91 111 Water volume 14 14 14 24 24 24 32 32 39 39 Inlet/outlet water connection inch 3 3 3 3 4 4 4 4 5 5 Weight Shipping kg 1.918 1.919 2.011 2.111 2.506 2.616 3.143 3.256 3.705 9.801 Operating kg 1.946 1.947 2.039 2.160 2.554 2.665 3.218 3.331 3.793 9.889 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard.
50 Air cooled Chiller & Heat Pump Air Cooled Chiller VLS 604-1204 153-307 kw Plate 410A Air cooled Scroll Technical feature 7 sizes Cooling capacity from 153,4 to 306,9 kw 3 versions: STD (Standard); HT (High Temperature); HPF (High Pressure Fans) 3 acoustic versions: BLN (Basic Low Noise), LN (Low Noise) and ELN (Extra Low Noise) Two refrigerant circuits Scroll compressors Microprocessor control Microchannel coils (CO only version) Electronic expansion valve Inverter fans and HT Brine versione for process application (on request) E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater and totaly heat recovery VLR Fan speed control (-18 C) Hydrokit with 1 or 2 pumps with or without buffer tank (500 lt) ( +1mt of lenght) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch Operating limit (to be confirmed following selection software issue) VLS 604-1204 Leaving water temperature Air temperature External static pressure 604 704 804 904 1004 1004 1204 Min Max Min Max Min Max Min Max Min Max Min Max Min Max Water C +6 to +15 Water with glycol C 0 to +15 Water with Glycol (Brine version) C -8 to +15 T K 3 to 8 BLN C -5 to +47 2-5 to +47 2 0 to +46 3 0 to +47 3 0 to +46 3 0 to +45 3 0 to +45 3 LN/ELN 1 C -5 to +45 2-5 to +45 2 0 to +44 3 0 to +45 3 0 to +44 3 0 to +42 3 0 to +42 3 HT C -18 to +49 2-18 to +49 2-18 to +48 3-18 to +49 3-18 to +48 3-18 to +47 3-18 to +47 3 Standard fans Pa 0 Inverter fans HPF Pa <120 1 Minimum air temperature -18 C with Fan speed control (standard ELN). 2 High Pressure at 40.5 ba. Chillers suitable for operation without buffer tank for water content greater than 3 liters of water per kw of output.
Technical feature Air cooled Chiller & Heat Pump 51 Air Cooled Chiller & Heat Pump VLS std/hpf 604-1204 BLN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 153,4 176,2 198,1 228,4 250,3 279,1 306,9 Power input 1 kw 55,8 66,0 72,3 83,1 86,9 100,0 114,9 EER 1 2,75 2,67 2,74 2,75 2,88 2,79 2,67 Energy efficiency class C D C C C C D ESEER 3,50 3,47 3,44 3,43 3,59 3,52 3,45 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 26.540 30.427 34.194 39.371 43.155 48.091 52.924 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 900 900 900 900 900 900 900 Air flow m 3 /h 63.000 68.300 68.300 85.000 80.000 75.500 75.500 Power input kw 5,7 5,7 5,7 7,6 7,6 7,6 7,6 Power input * kw 4,0 4,0 4,0 5,3 5,3 5,3 5,3 Static head pressure Pa from 0 to 120 Pa * Weight Shipping kg 1.303 1.478 1.611 1.745 1.795 1.810 1.815 Operating kg 1.315 1.490 1.625 1.770 1.820 1.835 1.840 Additional weights Versions HPF kg 30 30 30 40 40 40 40 With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Lenght mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 2 db(a) 91 91 91 92 92 93 93 Sound pressure level 3 db(a) 59 59 59 60 60 61 61 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * For version with High Pressure Fans (HPF).
52 Air cooled Chiller & Heat Pump Technical feature VLS std 604-1204 LN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 149,4 171,2 192,1 222,4 241,3 266,2 292,0 Power input 1 kw 56,4 66,4 73,3 83,6 88,7 104,0 120,2 EER 1 2,65 2,58 2,62 2,66 2,72 2,56 2,43 Energy efficiency class D D D D C D E ESEER 3,72 3,63 3,65 3,58 3,75 3,66 3,57 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 25.765 29.618 33.213 38.321 41.555 45.958 50.361 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 2 2 2 2 2 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 700 700 700 700 700 700 700 Air flow m 3 /h 47.300 52.200 52.200 63.700 58.800 54.900 54.900 Power input kw 3,6 3,6 3,6 4,8 4,8 4,8 4,8 Static head pressure Pa 0 Weight Shipping kg 1.303 1.478 1.611 1.745 1.795 1.810 1.815 Operating kg 1.315 1.490 1.625 1.770 1.820 1.835 1.840 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 2 db(a) 87 87 87 88 88 89 89 Sound pressure level 3 db(a) 55 55 55 56 56 57 57 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 53 Air Cooled Chiller & Heat Pump VLS std 604-1204 eln 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 145,4 166,3 186,2 216,5 234,4 258,2 282,1 Power input 1 kw 57,9 68,7 76,3 86,3 91,2 106,7 124,8 EER 1 2,51 2,42 2,44 2,51 2,57 2,42 2,26 Energy efficiency class D E E D D E F ESEER 3,62 3,52 3,53 3,59 3,68 3,58 3,47 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 25.112 28.758 32.129 37.272 40.368 44.513 48.658 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 2 2 2 2 2 2 Frontal surface mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed gir/min 550 550 550 550 550 550 550 Air flow m 3 /h 38.500 41.800 41.800 52.000 48.900 46.200 46.200 Power input kw 3 3 3 4 4 4 4 Static head pressure Pa 0 Weight Shipping kg 1.338 1.513 1.646 1.780 1.835 1.850 1.855 Operating kg 1.350 1.525 1.660 1.805 1.860 1.875 1.880 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 2 db(a) 83 83 83 84 84 85 85 Sound pressure level 3 db(a) 51 51 51 52 52 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
54 Air cooled Chiller & Heat Pump Technical feature VLS 604-1204 HT 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 156,1 178,6 200,9 231,7 254,2 282,4 313,3 Power input 2 kw 48,7 58,4 64,4 73,2 76,8 89,9 103,1 EER 2,79 2,74 2,82 2,80 2,93 2,83 2,77 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 26.849 30.719 34.554 39.852 43.722 48.572 53.887 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 2 2 2 2 2 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 1.110 1.110 1.110 1.110 1.110 1.110 1.110 Air flow m 3 /h 71.800 76.200 76.200 95.800 91.200 87.600 87.600 Power input kw 7,2 6,9 6,9 9,6 9,9 10 10 Static head pressure Pa 0 Weight Shipping kg 1.333 1.508 1.641 1.785 1.835 1.850 1.855 Operating kg 1.345 1.520 1.655 1.810 1.860 1.875 1.880 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 3 db(a) 99 99 99 100 100 100 100 Sound pressure level 4 db(a) 67 67 67 68 68 68 68 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 55 Air Cooled Chiller & Heat Pump VLR 604-1204 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 152,0 176,0 200,0 230,0 250,0 277,0 306,0 Power input 2 kw 49,0 58,5 64,5 73,5 77,0 90,0 103,0 Total heat rejection 3 kw 191,0 222,8 251,3 288,3 310,7 348,7 388,6 EER 3,10 3,01 3,10 3,13 3,25 3,08 2,97 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 26.144 30.272 34.400 39.560 43.000 47.644 52.632 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Heat recovery Qty 1 Plate exchanger AISI 316 Water volume l 11,5 11,5 13,3 25,2 25,2 25,2 25,2 Connection type Male GAS threaded Inlet/outlet connection diameter inch 2½ 2½ 2½ 3 3 3 3 Weight Shipping kg 1.513 1.702 1.853 2.051 2.180 2.270 2.279 Operating kg 1.536 1.725 1.880 2.101 2.230 2.320 2.329 Additional weights Version ELN kg 35 35 35 35 40 40 40 Versions HPF/HT kg 30 30 30 40 40 40 40 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 1 Data based on 7 C leaving chilled water temperature and 35 C ambient air temperature. 2 Input power (only compressors). 3 Data based on 7 C leaving chilled water temperature and 45 C condenser warm water temperature.
56 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScrew 370-1100 Air EVO CO 364-1.118 kw Shell & Tube Air cooled Screw 134a ENERGY EFFICIENCY COOLING MODE 2014 Technical features 12 sizes Cooling capacity from 364,1 to 1.117,9 kw 3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits Screw compressors Electronic expansion valve Brine version for process application LWT -8 C Polar Version for air temperature -18 C E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressor stepless control Desuperheater and total heat recovery (TR) Hydrokit with 1 or 2 pumps Mechanical gauges Pressostatic fan speed control Power factor corrector capacitors Sequence phases control (standard) Softstart Unit protection grilles Water filter Water flow switch Report to performance data
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 57 Air Cooled Chiller & Heat Pump SyScrew 370-1100 Air EVO CO Мin from 370 to 1100 Max Water С from +5 to +15 Leaving water temperature Water + glycol С from 0 to +15 Water + glycol (Brine Version) С from -8 to +15 T K from 3 to 8 - С da 0 a +49 Air temperature L/S С da 0 a +47 HT С da -10 a +51 Minimum Air temperature Polar Version C -18 External static pressure Standard fans Pа 0 Inverter fans Pа < 120 STD version 50 40 30 L/S version 50 40 30 T Air ( C) 20 10 14 2 1 T Air ( C) 20 10 14 2 1 0 4 3-10 16 15-20 -10-5 0 5 LWT ( C) 10 15 0 4 3-10 16 15-20 -10-5 0 5 LWT ( C) 10 15 1 Water. 2 Water + Glycol. 3 Water + FSC. 4 Water + Glycol + FSC. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit. 1 Water. 2 Water + Glycol. 3 Water + FSC. 4 Water + Glycol + FSC. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit. HT version 50 40 30 T Air ( C) 20 10 0 14 2 1-10 16 15-20 -10-5 0 5 LWT ( C) 10 15 1 Water. 2 Water + Glycol. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit.
58 Air cooled Chiller & Heat Pump Technical feature SyScrew 370-700 Air EVO CO (STD) 370 400 450 500 570 650 700 Cooling capacity 1 kw 364,1 414,5 445,5 502,9 562,1 625,5 712,9 Power input 1 kw 112,7 130,4 143,5 159,9 176,5 197,7 223,5 EER 1 3,23 3,18 3,11 3,15 3,18 3,16 3,19 Energy efficiency class A A A A A A A ESEER 3,75 3,69 3,60 3,65 3,69 3,67 3,70 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 62,7 71,4 76,8 86,7 96,9 107,8 123,0 Water pressure drop kpa 17,0 21,1 24,4 18,7 23,3 29,3 37,6 Inlet/outlet diameter inch 6 6 6 8 8 8 8 Condenser Qty 8 10 10 10 12 12 14 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 51,1 63,9 63,9 63,9 76,7 76,7 89,4 Power input kw 16,8 21,0 21,0 21,0 25,2 25,2 29,4 Weight Shipping kg 3.500 3.840 3.870 4.720 5.050 5.100 5.550 Operating kg 3.650 3.980 4.010 4.970 5.300 5.340 5.780 Dimensions Length mm 4.600 5.700 5.700 5.700 6.700 6.700 7.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 97 98 98 98 99 99 99 Sound pressure level at 10 m 3 db(a) 65 66 66 66 67 67 67 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 59 Air Cooled Chiller & Heat Pump SyScrew 750-1100 Air EVO CO (STD) 750 850 950 1000 1100 Cooling capacity 1 kw 749,2 839,0 961,8 1.019,0 1.117,9 Power input 1 kw 237,4 261,2 288,6 312,8 340,0 EER 1 3,16 3,21 3,33 3,26 3,29 Energy efficiency class A A A A A ESEER 3,66 3,73 3,87 3,78 3,81 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 129,0 144,5 165,7 175,6 192,7 Water pressure drop kpa 15,4 19,4 24,2 25,6 31,4 Inlet/outlet diameter inch 8 8 8 10 10 Condenser Qty 14 16 18 20 22 MCHX - Al/Alloy Fan Qty 14 16 18 20 22 Air flow m 3 /s 89,4 102,2 115,0 127,8 140,6 Power input kw 29,4 33,6 37,8 42,0 46,2 Weight Shipping kg 6.730 7.030 7.460 7.840 8.260 Operating kg 7.120 7.420 7.840 8.210 8.660 Dimensions Length mm 7.800 8.800 9.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 100 100 101 101 102 Sound pressure level at 10 m 3 db(a) 67 67 68 68 69 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
60 Air cooled Chiller & Heat Pump Technical feature SyScrew 370-700 Air EVO CO L 370 400 450 500 570 650 700 Cooling capacity 1 kw 354,6 401,7 438,5 478,8 547,5 610,5 702,3 Power input 1 kw 111,8 126,4 142,5 159,0 176,4 199,6 224,3 EER 1 3,17 3,18 3,08 3,01 3,10 3,06 3,13 Energy efficiency class A A B B A B A ESEER 4,07 4,19 4,07 4,00 4,11 4,05 4,14 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 61,1 69,2 75,6 82,5 94,3 105,3 121,1 Water pressure drop kpa 16 20 24 17 22 28 37 Inlet/outlet diameter inch 6 6 6 8 8 8 8 Condenser Qty 8 10 10 10 12 12 14 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 42,4 53,1 53,1 53,1 63,7 63,7 74,3 Power input kw 9,2 11,5 11,5 11,5 13,8 13,8 16,1 Weight Shipping kg 3.500 3.840 3.870 4.720 5.050 5.100 5.550 Operating kg 3.650 3.980 4.010 4.970 5.300 5.340 5.780 Dimensions Length mm 4.600 5.700 5.700 5.700 6.700 6.700 7.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 91 92 92 92 93 93 94 Sound pressure level at 10 m 3 db(a) 59 60 60 60 61 61 61 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 61 Air Cooled Chiller & Heat Pump SyScrew 750-1100 Air EVO CO L 750 850 950 1000 1100 Cooling capacity 1 kw 722,2 814,4 922,4 981,4 1.086,0 Power input 1 kw 237,7 264,2 288,3 309,8 339,3 EER 1 3,04 3,08 3,20 3,17 3,20 Energy efficiency class B B A A A ESEER 4,04 4,08 4,23 4,21 4,24 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 124,5 140,5 158,9 169,1 187,2 Water pressure drop kpa 31 39 22 24 30 Inlet/outlet diameter inch 8 8 8 10 10 Condenser Qty 14 16 18 20 22 MCHX - Al/Alloy Fan Qty 14 16 18 20 22 Air flow m 3 /s 74,3 84,9 95,5 106,1 116,7 Power input kw 16,1 18,4 20,7 23,0 25,3 Weight Shipping kg 6.730 7.030 7.460 7.840 8.260 Operating kg 7.120 7.420 7.840 8.210 8.660 Dimensions Length mm 7.800 8.800 9.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 94 94 95 95 96 Sound pressure level at 10 m 3 db(a) 61 61 62 62 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
62 Air cooled Chiller & Heat Pump Technical feature SyScrew 370-700 Air EVO CO S 370 400 450 500 570 650 700 Cooling capacity 1 kw 354,6 401,7 438,5 478,8 547,5 610,5 702,3 Power input 1 kw 111,8 126,4 142,5 159,0 176,4 199,6 224,3 EER 1 3,17 3,18 3,08 3,01 3,10 3,06 3,13 Energy efficiency class A A B B A B A ESEER 4,07 4,19 4,07 4,00 4,11 4,05 4,14 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 61,1 69,2 75,6 82,5 94,3 105,3 61,1 Water pressure drop kpa 16 20 24 17 22 28 16 Inlet/outlet diameter inch 6 6 6 8 8 8 8 Condenser Qty 8 10 10 10 12 12 14 MCHX - Al/Alloy Fan Qty 8 10 10 10 12 12 14 Air flow m 3 /s 42,4 53,1 53,1 53,1 63,7 63,7 74,3 Power input kw 9,2 11,5 11,5 11,5 13,8 13,8 16,1 Weight Shipping kg 3.590 3.930 3.950 4.810 5.140 5.200 5.650 Operating kg 3.740 4.070 4.100 5.060 5.390 5.430 5.880 Dimensions Length mm 4.600 5.700 5.700 5.700 6.700 6.700 7.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 87 88 88 88 89 89 90 Sound pressure level at 10 m 3 db(a) 55 56 56 56 57 57 58 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 63 Air Cooled Chiller & Heat Pump SyScrew 750-1100 Air EVO CO S 750 850 950 1000 1100 Cooling capacity 1 kw 722,2 814,4 922,4 981,4 1086,0 Power input 1 kw 237,7 264,2 288,3 309,8 339,3 EER 1 3,04 3,08 3,20 3,17 3,20 Energy efficiency class B B A A A ESEER 4,04 4,08 4,23 4,21 4,24 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 69,2 75,6 82,5 94,3 105,3 Water pressure drop kpa 20 24 17 22 28 Inlet/outlet diameter inch 8 8 8 10 10 Condenser Qty 14 16 18 20 22 MCHX - Al/Alloy Fan Qty 14 16 18 20 22 Air flow m 3 /s 74,3 84,9 95,5 106,1 116,7 Power input kw 16,1 18,4 20,7 23,0 25,3 Weight Shipping kg 6.830 7.130 7.570 7.940 8.360 Operating kg 7.220 7.520 7.940 8.310 8.760 Dimensions Length mm 7.800 8.800 9.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 90 90 91 91 92 Sound pressure level at 10 m 3 db(a) 57 57 58 58 59 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
64 Air cooled Chiller & Heat Pump Air Cooled Chiller SyScrew 360-1300 Air CO 366-1.320 kw Shell & Tube 134a Air cooled Screw Technical features 19 sizes Cooling capacity from 366 to 1.320 kw 3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits Screw compressors Valvola di espansione elettronica Brine version for process application LWT-8 C Polar Version for air temperature -18 C E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors stepless control Desuperheater and totaly heat recovery Fan speed control Hydrokit with 1 or 2 pumps with ot without buffer tank Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 65 Air Cooled Chiller & Heat Pump SyScrew 360-1300 Air CO Мin from 360 to 1300 Max Water С from +5 to +15 Leaving water temperature Water + glycol С from 0 to +15 Water + glycol (Brine Version) С from -8 to +15 T K from 3 to 8 - С from 0 to +48 L С from 0 to +46 Air temperature S С from -10 to +42 HT С from -10 to +50 Minimum Air temperature Polar Version C -18 External static pressure Standard fans Pа 0 Inverter fans Pа < 120 STD version 50 L version 50 40 30 40 30 T Air ( C) 20 10 14 2 1 T Air ( C) 20 10 14 2 1 0-10 4 3 16 15-20 -10-5 0 5 10 15 LWT ( C) 1 Water. 2 Water + Glycol. 3 Water + FSC. 4 Water + Glycol + FSC. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit. 0-10 4 3 16 15-20 -10-5 0 5 10 15 LWT ( C) 1 Water. 2 Water + Glycol. 3 Water + FSC. 4 Water + Glycol + FSC. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit. S version 50 HT version 50 40 30 40 30 T Air ( C) 20 10 14 2 1 T Air ( C) 20 10 14 2 1 0 0-10 16 15-20 -10-5 0 5 10 15 LWT ( C) 1 Water. 2 Water + Glycol. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit. -10 16 15-20 -10-5 0 5 10 15 LWT ( C) 1 Water. 2 Water + Glycol. 14 Brine Version. 15 Polar Version. 16 Polar + Glycol. 1 + 2 Standard unit.
66 Air cooled Chiller & Heat Pump Technical feature SyScrew 360-580 Air CO (STD) 360 410 450 480 500 540 580 Cooling capacity 1 kw 365 413 445 480 505 540 575 Power input 1 kw 134,4 151,5 167,7 176,3 184,1 198,6 212,5 EER 1 2,71 2,73 2,65 2,72 2,74 2,72 2,70 Energy efficiency class C C D C C C C ESEER 3,15 3,16 3,18 3,27 3,18 3,26 3,14 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 63,0 71,3 76,8 82,9 87,0 93,1 99,1 Water pressure drop kpa 57,3 39,0 45,3 52,4 31,8 36,3 40,4 Inlet/outlet diameter inch 5 6 6 6 6 6 6 Condenser Qty 6 8 8 8 8 9 10 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 38,3 51,1 51,1 51,1 51,1 57,5 63,9 Power input kw 12,6 16,8 16,8 16,8 16,8 18,9 21,0 Weight Shipping kg 3.200 3.520 3.830 4.140 4.170 4.400 4.660 Operating kg 3.300 3.670 3.990 4.290 4.320 4.550 4.800 Dimensions Length mm 4.600 4.600 4.600 4.600 4.600 5.700 6.700 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 96 97 97 97 97 98 98 Sound pressure level at 10 m 3 db(a) 64 65 65 65 65 66 65 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 67 Air Cooled Chiller & Heat Pump SyScrew 650-1000 Air CO (STD) 650 720 800 850 910 970 1000 Cooling capacity 1 kw 652 713 794 851 909 971 1.008 Power input 1 kw 236,8 253,4 275,7 298,9 320,2 340,5 350,7 EER 1 2,75 2,81 2,88 2,85 2,84 2,85 2,87 Energy efficiency class C C C C C C C ESEER 3,19 3,38 3,45 3,42 3,29 3,42 3,33 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 112,4 123,0 137,0 147,0 157,0 167,6 174,1 Water pressure drop kpa 30,4 36,2 46,5 53,4 60,2 55,4 60,2 Inlet/outlet diameter inch 6 6 8 8 8 8 8 Condenser Qty 12 12 12 14 14 15 16 MCHX - Al/Alloy Fan Qty 12 12 12 14 14 15 16 Air flow m 3 /s 76,7 76,7 76,7 89,4 89,4 95,8 102,2 Power input kw 25,2 25,2 25,2 29,4 29,4 31,5 33,6 Weight Shipping kg 5.080 5.500 5.990 6.510 6.600 6.810 6.900 Operating kg 5.330 5.760 6.220 6.750 6.830 7.090 7.180 Dimensions Length mm 6.700 6.700 6.700 8.800 8.800 8.800 8.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 99 99 99 100 100 100 100 Sound pressure level at 10 m 3 db(a) 66 66 66 67 67 67 67 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
68 Air cooled Chiller & Heat Pump Technical feature SyScrew 1070-1300 Air CO (STD) 1070 1130 1170 1200 1300 Cooling capacity 1 kw 1.071 1.132 1.172 1.218 1.316 Power input 1 kw 371,8 391,8 410,5 431,2 465,9 EER 1 2,88 2,89 2,85 2,82 2,82 Energy efficiency class C C C C C ESEER 3,46 3,35 3,43 3,28 3,28 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 1 1 1 1 Shell & Tube Water flow rate m 3 /h 184,7 195,3 202,1 210,0 227,0 Water pressure drop kpa 30,7 34,3 35,1 37,9 43,9 Inlet/outlet diameter inch 8 8 8 8 10 Condenser Qty 17 18 19 20 22 MCHX - Al/Alloy Fan Qty 17 18 19 20 22 Air flow m 3 /s 108,6 115,0 121,4 127,8 140,6 Power input kw 35,7 37,8 39,9 42,0 46,2 Weight Shipping kg 7.490 7.760 7.970 8.180 8.570 Operating kg 7.880 8.150 8.350 8.560 8.940 Dimensions Length mm 9.900 10.900 10.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 100 101 101 101 102 Sound pressure level at 10 m 3 db(a) 67 68 68 68 69 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 69 Air Cooled Chiller & Heat Pump SyScrew 360-580 Air CO L 360 410 450 480 500 540 580 Cooling capacity 1 kw 357 405 436 470 495 529 563 Power input 1 kw 133,4 149,2 166,0 174,9 183,0 197,1 210,5 EER 1 2,68 2,72 2,63 2,69 2,70 2,68 2,68 Energy efficiency class D C D D C D D ESEER 3,32 3,37 3,37 3,45 3,35 3,45 3,32 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 61,7 69,9 75,3 81,2 85,3 91,2 97,2 Water pressure drop kpa 55,1 37,5 43,5 50,4 30,5 34,8 38,8 Inlet/outlet diameter inch 5 6 6 6 6 6 6 Condenser Qty 6 8 8 8 8 9 10 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 31,8 42,4 42,4 42,4 42,4 47,8 53,1 Power input kw 6,9 9,2 9,2 9,2 9,2 10,4 11,5 Weight Shipping kg 3.200 3.520 3.830 4.140 4.170 4.400 4.660 Operating kg 3.300 3.670 3.990 4.290 4.320 4.550 4.800 Dimensions Length mm 4.600 4.600 4.600 4.600 4.600 5.700 6.700 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 90 91 91 91 91 92 92 Sound pressure level at 10 m 3 db(a) 58 59 59 59 59 60 59 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
70 Air cooled Chiller & Heat Pump Technical feature SyScrew 650-1000 Air CO L 650 720 800 850 910 970 1000 Cooling capacity 1 kw 639 699 778 835 891 952 988 Power input 1 kw 233,7 250,9 272,0 296,0 318,2 338,2 347,8 EER 1 2,73 2,78 2,86 2,82 2,80 2,81 2,84 Energy efficiency class C C C C C C C ESEER 3,39 3,58 3,67 3,62 3,48 3,61 3,52 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Tipo Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 110,1 120,5 134,2 144,1 153,9 164,3 170,6 Water pressure drop kpa 29,2 34,8 44,7 51,3 57,8 53,2 57,8 Inlet/outlet diameter inch 6 6 8 8 8 8 8 Condenser Qty 12 12 12 14 14 15 16 MCHX - Al/Alloy Fan Qty 12 12 12 14 14 15 16 Air flow m 3 /s 63,7 63,7 63,7 74,3 74,3 79,6 84,9 Power input kw 13,8 13,8 13,8 16,1 16,1 17,3 18,4 Weight Shipping kg 5.080 5.500 5.990 6.510 6.600 6.810 6.900 Operating kg 5.330 5.760 6.220 6.750 6.830 7.090 7.180 Dimensions Length mm 6.700 6.700 6.700 8.800 8.800 8.800 8.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 93 93 93 94 94 94 94 Sound pressure level at 10 m 3 db(a) 60 60 60 61 61 61 61 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 71 Air Cooled Chiller & Heat Pump SyScrew 1070-1300 Air CO L 1070 1130 1170 1200 1300 Cooling capacity 1 kw 1.050 1.110 1.148 1.193 1.290 Power input 1 kw 368,8 388,6 407,0 427,4 461,4 EER 1 2,85 2,86 2,82 2,79 2,80 Energy efficiency class C C C C C ESEER 3,65 3,54 3,62 3,46 3,47 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 181,0 191,3 198,0 205,8 222,5 Water pressure drop kpa 29,5 32,9 33,7 36,4 42,2 Inlet/outlet diameter inch 8 8 8 8 10 Condenser Qty 17 18 19 20 22 MCHX - Al/Alloy Fan Qty 17 18 19 20 22 Air flow m 3 /s 90,2 95,5 100,8 106,1 116,7 Power input kw 19,6 20,7 21,9 23,0 25,3 Weight Shipping kg 7.490 7.760 7.970 8.180 8.570 Operating kg 7.880 8.150 8.350 8.560 8.940 Dimensions Length mm 9.900 10.900 10.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 94 95 95 95 96 Sound pressure level at 10 m 3 db(a) 61 62 62 62 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
72 Air cooled Chiller & Heat Pump Technical feature SyScrew 360-580 Air CO S 360 410 450 480 500 540 580 Cooling capacity 1 kw 339 385 414 446 469 502 535 Power input 1 kw 140,4 157,0 174,7 184,1 192,8 207,6 221,6 EER 1 2,42 2,45 2,37 2,43 2,43 2,42 2,41 Energy efficiency class E E E E E E E ESEER 3,14 3,18 3,18 3,26 3,16 3,25 3,13 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 58,6 66,3 71,4 77,1 80,9 86,6 92,2 Water pressure drop kpa 49,6 33,8 39,2 45,4 27,5 31,4 35,0 Inlet/outlet diameter inch 5 6 6 6 6 6 6 Condenser Qty 6 8 8 8 8 9 10 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 25,8 34,4 34,4 34,4 34,4 38,6 43,1 Power input kw 6,9 9,2 9,2 9,2 9,2 10,4 11,5 Weight Shipping kg 3.280 3.600 3.920 4.230 4.260 4.490 4.760 Operating kg 3.380 3.760 4.080 4.390 4.410 4.640 4.900 Dimensions Length mm 4.600 4.600 4.600 4.600 4.600 5.700 6.700 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 86 87 87 87 87 88 88 Sound pressure level at 10 m 3 db(a) 54 55 55 55 55 56 55 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 73 Air Cooled Chiller & Heat Pump SyScrew 650-1000 Air CO S 650 720 800 850 910 970 1000 Cooling capacity 1 kw 606 663 738 792 846 903 938 Power input 1 kw 246,1 264,3 286,3 311,6 335,0 356,1 366,0 EER 1 2,46 2,51 2,58 2,54 2,53 2,54 2,56 Energy efficiency class E D D D D D D ESEER 3,20 3,37 3,47 3,42 3,28 3,41 3,33 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 104,5 114,4 127,4 136,7 146,0 155,9 161,9 Water pressure drop kpa 26,3 31,3 40,2 46,2 52,0 47,9 52,0 Inlet/outlet diameter inch 6 6 8 8 8 8 8 Condenser Qty 12 12 12 14 14 15 16 MCHX - Al/Alloy Fan Qty 12 12 12 14 14 15 16 Air flow m 3 /s 51,7 51,7 51,7 60,3 60,3 64,6 68,9 Power input kw 13,8 13,8 13,8 16,1 16,1 17,3 18,4 Weight Shipping kg 5.180 5.600 6.090 6.620 6.700 6.920 7.010 Operating kg 5.430 5.860 6.320 6.850 6.930 7.190 7.280 Dimensions Length mm 6.700 6.700 6.700 8.800 8.800 8.800 8.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 89 89 89 89 90 90 90 Sound pressure level at 10 m 3 db(a) 56 56 56 56 57 57 57 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
74 Air cooled Chiller & Heat Pump Technical feature SyScrew Air 1070-1300 Air CO S 1070 1130 1170 1200 1300 Cooling capacity 1 kw 996 1.053 1.090 1.133 1.224 Power input 1 kw 388,5 409,3 428,7 450,2 485,8 EER 1 2,56 2,57 2,54 2,52 2,52 Energy efficiency class D D D D D ESEER 3,45 3,34 3,42 3,27 3,27 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 171,7 181,6 187,9 195,3 211,1 Water pressure drop kpa 26,6 29,6 30,3 32,8 38,0 Inlet/outlet diameter inch 8 8 8 8 10 Condenser Qty 17 18 19 20 22 MCHX - Al/Alloy Fan Qty 17 18 19 20 22 Air flow m 3 /s 73,2 77,5 81,8 86,1 94,7 Power input kw 19,6 20,7 21,9 23,0 25,3 Weight Shipping kg 7.590 7.860 8.070 8.280 8.670 Operating kg 7.980 8.250 8.450 8.660 9.040 Dimensions Length mm 9.900 10.900 10.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 90 91 91 91 92 Sound pressure level at 10 m 3 db(a) 57 58 58 58 59 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 75 Air Cooled Chiller & Heat Pump SyScrew 360-580 Air CO HT 360 410 450 480 500 540 580 Cooling capacity 1 kw 372 422 454 489 515 550 586 Power input 1 kw 138,1 156,9 172,8 181,2 188,8 204,1 218,8 EER 1 2,69 2,69 2,63 2,70 2,73 2,70 2,68 Energy efficiency class D D D C C D D ESEER 3,12 3,12 3,15 3,24 3,16 3,24 3,11 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Part Winding Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 64,3 72,8 78,4 84,5 88,8 94,9 101,1 Water pressure drop kpa 59,7 40,6 47,2 54,6 33,1 37,7 42,0 Inlet/outlet diameter inch 5 6 6 6 6 6 6 Condenser Qty 6 8 8 8 8 9 10 MCHX - Al/Alloy Fan Qty 6 8 8 8 8 9 10 Air flow m 3 /s 46,8 62,4 62,4 62,4 62,4 70,3 78,1 Power input kw 18,6 24,8 24,8 24,8 24,8 27,9 31,0 Weight Shipping kg 3.200 3.520 3.830 4.140 4.170 4.400 4.660 Operating kg 3.300 3.670 3.990 4.290 4.320 4.550 4.800 Dimensions Length mm 4.600 4.600 4.600 4600 4.600 5.700 6700 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 102 103 103 103 103 104 104 Sound pressure level at 10 m 3 db(a) 70 71 71 71 71 72 71 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
76 Air cooled Chiller & Heat Pump Technical feature SyScrew 650-1000 Air CO HT 650 720 800 850 910 970 1000 Cooling capacity 1 kw 665 727 809 868 927 990 1.028 Power input 1 kw 244,7 261,0 285,0 307,7 328,7 349,6 360,6 EER 1 2,72 2,79 2,84 2,82 2,82 2,83 2,85 Energy efficiency class C C C C C C C ESEER 3,15 3,34 3,41 3,39 3,27 3,40 3,31 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 114,6 125,4 139,7 149,9 160,2 171,0 177,5 Water pressure drop kpa 31,6 37,7 48,4 55,5 62,6 57,7 62,6 Inlet/outlet diameter inch 6 6 8 8 8 8 8 Condenser Qty 12 12 12 14 14 15 16 MCHX - Al/Alloy Fan Qty 12 12 12 14 14 15 16 Air flow m 3 /s 93,7 93,7 93,7 109,3 109,3 117,1 124,9 Power input kw 37,2 37,2 37,2 43,4 43,4 46,5 49,6 Weight Shipping kg 5.080 5.500 5.990 6.510 6.600 6.810 6.900 Operating kg 5.330 5.760 6.220 6.750 6.830 7.090 7.180 Dimensions Length mm 6.700 6.700 6.700 8.800 8.800 8.800 8.800 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 105 105 105 106 106 106 106 Sound pressure level at 10 m 3 db(a) 72 72 72 73 73 73 73 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 77 Air Cooled Chiller & Heat Pump SyScrew 1070-1300 Air CO HT 1070 1130 1170 1200 1300 Cooling capacity 1 kw 1092 1155 1195 1242 1342 Power input 1 kw 382,2 402,9 422,3 443,6 479,8 EER 1 2,86 2,87 2,83 2,80 2,80 Energy efficiency class C C C C C ESEER 1 3,43 3,33 3,40 3,25 3,25 Refrigerant HFC 134a Number of refrigerant circuits 2 2 2 2 2 Compressor Qty 2 Screw Part load steps % 25-50-62-75-87-100 Power supply 400V/3/50Hz Start-up type Y/Δ Evaporator Qty 1 Shell & Tube Water flow rate m 3 /h 188,4 199,2 206,1 214,2 231,6 Water pressure drop kpa 32,0 35,6 36,5 39,5 45,7 Inlet/outlet diameter inch 8 8 8 8 10 Condenser Qty 17 18 19 20 22 MCHX - Al/Alloy Fan Qty 17 18 19 20 22 Air flow m 3 /s 132,7 140,5 148,3 156,1 171,7 Power input kw 52,7 55,8 58,9 62,0 68,2 Weight Shipping kg 7.490 7.760 7.970 8.180 8.570 Operating kg 7.880 8.150 8.350 8.560 8.940 Dimensions Length mm 9.900 10.900 10.900 10.900 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 106 107 107 107 108 Sound pressure level at 10 m 3 db(a) 73 74 74 74 75 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
78 Air cooled Chiller & Heat Pump Air Cooled Chiller SLS HE 5204-8404 1.142-1.687 kw Shell & Tube 134a Air cooled Screw Technical feature 8 sizes Cooling capacity from 1142 to 1.687 kw 3 acoustic versions: BLN (Basic Low Noise) LN (Low Noise) ELN (Extra Low Noise) Four indipendent refrigerant circuit 4 Screw compressors Electronic expansion valve Accessories and options BMS interface Coils treatments Compressors acoustic box (standard) Compressors stepless control Desuperheater and totaly heat recovery Fan speed control (-15 C) Hydrokit with 1 or 2 pumps with ot without buffer tank Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 79 Air Cooled Chiller & Heat Pump SLS HE 5204-6404 Leaving water temperature 5204 5604 6004 6404 Min Max Min Max Min Max Min Max Water C from +5 to +15 T K from 3 to 8 BLN C from -5 2 to 48 from -5 2 to 48 from -5 2 to 47 from -5 2 to 47 Air temperature LN C from -5 2 to 45 from -5 2 to 45 from -5 2 to 44 from -5 2 to 44 ELN C from -15 to 45 from -15 to 45 from -15 to 44 from -15 to 44 External static pressure Standard fans Pа 0 High pressure fans (HPF) Pа 100 2 Minimum Air Temperature -15 C with fan speed control (option). SLS HE 6804-8404 Leaving water temperature 6804 7204 7804 8404 Min Max Min Max Min Max Min Max Water C from +5 to +15 T K from 3 to 8 BLN C from -5 2 to 47 da -5 2 a 44 from -5 2 to 44 from -5 2 to 44 Air temperature LN C from -5 2 to 41 from -5 2 to 41 from -5 2 to 41 from -5 2 to 41 ELN C from -15 to 41 from -15 to 41 from -15 to 41 from -15 to 41 External static pressure Standard fans Pа 0 High pressure fans (HPF) Pа 100 2 Minimum Air Temperature -15 C with fan speed control (option).
80 Air cooled Chiller & Heat Pump Technical feature SLS 5204-8404 HE BLN 5204 5604 6004 6404 6804 7204 7804 8404 Cooling capacity 1 kw 1.142,0 1.208,0 1.292,8 1.406,4 1.482,2 1.557,9 1.637,2 1.686,9 Power input 1 kw 326,2 342,4 377,8 419,8 467 514,2 543,3 575,0 EER 1 3,50 3,50 3,40 3,40 3,20 3,00 3,00 2,90 Part load steps % 9 Refrigerant HFC 134a Number of refrigerant circuits 4 Compressor Qty 4 Screw Evaporator Qty 2 Shell & Tube Water flow l/h 196.424 207.776 222.361 241.900 254.938 267.958 281.598 290.146 Diametro ingresso/uscita inch 6 6 6 8 8 8 8 8 Condenser Qty 8 Total coil face area per coil mm 2 12 Fan Qty 20 20 24 24 24 24 24 24 Air flow m 3 /h 420.000 408.000 440.000 440.000 440.000 440.000 440.000 440.000 Speed rpm 900 900 900 900 900 900 900 900 Power input kw 36 36 43,2 43,2 43,2 43,2 43,2 43,2 Weight Shipping kg 11.344 12.089 12.936 13.679 13.756 13.944 14.050 14.167 Operating kg 11.580 12.561 13.388 14.085 14.135 14.421 14.542 14.659 Dimensions Length mm 12.000 12.000 12.000 12.000 12.000 12.000 12.000 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 102 102 103 103 103 103 103 103 Sound pressure level at 10 m 3 db(a) 69 69 70 70 70 70 70 70 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 81 Air Cooled Chiller & Heat Pump SLS HE 5204-8404 LN 5204 5604 6004 6404 6804 7204 7804 8404 Cooling capacity 1 kw 1.096,3 1.159,7 1.241,1 1.350,1 1.422,9 1.495,6 1.571,7 1.619,4 Power input 1 kw 345,8 362,9 400,5 445,0 495,0 545,1 575,9 609,5 EER 1 3,20 3,20 3,10 3,00 2,90 2,70 2,70 2,70 Part load steps % 9 Refrigerant HFC 134a Number of refrigerant circuits 4 Compressor Qty 4 Screw Evaporator Qty 2 Shell & Tube Water flow l/h 188.563 199.468 213.469 232.217 244.738 257.243 270.332 278.536 Inlet/outlet diameter inch 6 6 6 8 8 8 8 8 Condenser Qty 8 Total coil face area per coil mm 2 12 Fan Qty 20 20 24 24 24 24 24 24 Air flow m 3 /h 285.600 277.440 299.200 299.200 299.200 299.200 299.200 299.200 Speed rpm 700 700 700 700 700 700 700 700 Power input kw 25 25 30 30 30 30 30 30 Weight Shipping kg 11.560 12.305 13.152 13.895 13.972 14.160 14.266 14.383 Operating kg 11.796 12.777 13.604 14.301 14.351 14.637 14.758 14.875 Dimensions Length mm 12.000 12.000 12.000 12.000 12.000 12.000 12.000 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 96 96 97 97 97 97 97 97 Sound pressure level at 10 m 3 db(a) 63 63 64 64 64 64 64 64 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
82 Air cooled Chiller & Heat Pump Technical feature SLS HE 5204-8404 ELN 5204 5604 6004 6404 6804 7204 7804 8404 Cooling capacity 1 kw 1.096,3 1.159,7 1.241,1 1.350,1 1.422,9 1.495,6 1.571,7 1.619,4 Power input 1 kw 345,8 362,9 400,5 445,0 495,0 545,1 575,9 609,5 EER 1 3,20 3,20 3,10 3,00 2,90 2,70 2,70 2,70 Part load steps % 9 Refrigerant HFC 134a Number of refrigerant circuits 4 Compressors Qty 4 Screw Evaporator Qty 2 Shell & Tube Water flow l/h 188.563 199.468 213.469 232.217 244.738 257.243 270.332 278.536 Inlet/outlet diameter inch 6 6 6 8 8 8 8 8 Condenser Qty 8 Total coil face area per coil mm 2 12 Fan Qty 20 20 24 24 24 24 24 24 Air flow m 3 /h 285.600 277.440 299.200 299.200 299.200 299.200 299.200 299.200 Speed rpm 700 700 700 700 700 700 700 700 Power input kw 25 25 30 30 30 30 30 30 Weight Shipping kg 11.560 12.305 13.152 13.895 13.972 14.160 14.266 14.383 Operating kg 11.796 12.777 13.604 14.301 14.351 14.637 14.758 14.875 Dimensions Length mm 12.000 12.000 12.000 12.000 12.000 12.000 12.000 12.000 Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 2 db(a) 90 90 91 91 93 93 93 93 Sound pressure level at 10 m 3 db(a) 57 57 58 58 60 60 60 60 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Air Cooled Chiller & Heat Pump
84 Air cooled Chiller & Heat Pump Inverter Air Cooled Heat Pump Mini SysAqua DCI 5-16 NEW Q1 2016 5-14.5kW Air cooled Scroll 410A 5.5-16 kw Plate INVERTER Inverter Technical feature 6 sizes Cooling capacity from 5,0 to 14,5 kw Heating capacity from 5,5 to 16,0 kw Operating Range: from -5 to 46 C cooling and from -15 to 27 C heating DC Inverter technology: Compressor and outdoor fan motor One refrigerant circuit with DC compressor Blue fin coil LWT up to +55 C in heating mode, outdoor temperature down to -15 C. Bi-flow electronic expansion valve as standard Stainless steel plate heat exchanger with antifreeze protection Centrifugal pump as standard Operating low water content in the plant Accessories and options Automatic circuit breaker (standard) Coil grilles (standard) Fan speed control (standard) Remote on/off Sequence phases control (standard) Softstart (standard) Water differential pressure switch (standard from 10 to 16) Water flow switch ( standard from 5 to 7 ) Operating limit (to be confirmed following selection software issue) Cooling mode Mini SysAqua DCI 5-16 Min Max Leaving water temperature* C 4 20 Air temperature C -5 46 Heating mode Mini SysAqua DCI 5-16 Min Max Leaving water temperature* C 30 55 Air temperature C -15 27
Technical feature Air cooled Chiller & Heat Pump 85 Air Cooled Chiller & Heat Pump Mini SysAqua DCI 5 7 10 12 14 16 Cooling Capacity 4 kw 5.0 7.0 10.0 11.2 12.5 14.5 Power input 4 kw 1.55 2.25 2.95 3.38 3.9 4.53 EER 4 3.23 3.11 3.39 3.31 3.2 3.2 Energy Efficiency Class A A A A A A Cooling Capacity 2 kw 6.57 7.88 10.9 14.5 15.17 16.70 Power input 2 kw 1.27 1.84 2.95 2.8 3.13 3.73 EER 2 5.16 4.28 4.39 5.17 4.84 4.48 Heating Capacity 3 kw 5.5 8.0 11.0 12.3 13.8 16.0 Power input 3 kw 1.7 2.5 3.14 3.72 4.25 4.85 COP 3 3.24 3.2 3.50 3.31 3.25 3.3 Energy Efficiency Class A A A A A A Heating Capacity 1 kw 6.32 8.29 10.96 13.75 15.30 16.97 Power input 1 kw 1.52 2.13 2.51 2.85 3.15 3.86 Part load steps % Stepless Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50 400/3/50 400/3/50 400/3/50 Startup type Soft-start (inverter) Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Number / 1 / Rotary Evaporator Qty 1 Plate exchanger Water flow rate l/h 860 1200 1720 1920 2150 2490 Pressure drop kpa 15 15 18 18 18 19 Fan Qty 1 1 1 2 2 2 Air flow m 3 /h 5.100 5.100 7.000 7.000 7.000 7.000 Power input W 170 170 100 100 100 100 Pump Qty 1 1 1 1 1 1 Power input (H/M/L) W 93/67/46 93/67/46 210/175/120 210/175/120 210/175/120 210/175/120 Available static pressure m 5.5 5.5 8 8 8 8 Water Connections Inlet/Outlet Diameter inch 1" 1" 1 1/4 1 1/4 1 1/4 1 1/4 Weight Shipping kg 91 91 121 121 122 122 Operating kg 81 81 110 110 111 111 Dimensions Lenght mm 990 990 970 970 970 970 Width mm 354 354 400 400 400 400 Height mm 966 966 1327 1327 1327 1327 Acoustical data Sound pressure level 5 db(a) 58 58 59 59 60 60 1 Data refers to chilled water inlet/outlet temperature: 12/7 C,outdoor ambient temperature 35 C DB.. 2 Data refers to chilled water inlet/outlet temperature: 23/18 C,outdoor ambient temperature 35 C DB. 3 Data refers to warm water inlet/outlet temperature: 40/45 C,outdoor ambient temperature 7 C DB/6 C WB. 4 Data refers to warm water inlet/outlet temperature: 30/35 C,outdoor ambient temperature 7 C DB/6 C WB. 5 Sound pressure levels is tested 1m away in front of the unit in a semi-anechoic room(sound pressure).
86 Air cooled Chiller & Heat Pump Inverter Air Cooled Heat Pump SyScroll 20-30 Air EVO HP 20-36 kw Air cooled Scroll 410A 20-34 kw Plate INVERTER Inverter Technical feature 2 sizes Cooling capacity from 20,0 to 35,9 kw Heating capacity from 20,4 to 34,0 kw Operating Range: from -10 to 45 C cooling and from -15 to 20 C heating Inverter driven compressor A single inverter driven 3-phase scroll compressor equipped with brushless motor with variable frequency (20-120 Hz) One refrigerant circuit Bi-flow electronic expansion valve Multistage centrifugal pump as standard Bluefin coil Operating low water content in the plant ENERGY EFFICIENCY COOLING MODE 2014 Report to performance data Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coils treatments Coil grilles (standard) Fan speed control (standard) In/Out Valve kit Power factor corrector capacitors (standard) Remote on/off Sequence phases control (standard) Softstart (standard) Water differential pressure switch (standard) Water filter (standard) & Water flow switch Operating limit (to be confirmed following selection software issue) Cooling mode 20 30 SyScroll 20-30 Air EVO HP Min Max Min Max Leaving water temperature* C -8 18-8 18 T water K 3 7 3 7 Air temperature C -10 45-10 45 Heating mode 20 30 SyScroll 20-30 Air EVO HP Min Max Min Max Leaving water temperature* C 25 55 25 55 T water K 3 7 3 7 Air temperature C -15 20-15 20 * Below 5 C, glycol is required. For operation below 0 C contact sales office. Chillers suitable for operation without buffer tank for water content greater than 2,5 liters of water per kw of output.
Technical feature Air cooled Chiller & Heat Pump 87 Air Cooled Chiller & Heat Pump SyScroll 20-30 Air EVO HP 20 30 Heating Capacity (min/nom/max) 1 kw 9,94 20,4 29,4 11,5 26,1 34,0 Power input 1 kw 2,98 5,02 8,37 3,01 6,45 9,80 COP 1 kw/kw 3,34 4,06 3,51 3,82 4,05 3,47 Eurovent class A A Cooling Capacity (min/nom/max) 2 kw 9,33 20,0 28,0 13,9 29,0 35,9 Power input 2 kw 2,38 4,15 6,61 3,51 7,24 13,0 EER 2 kw/kw 3,92 4,82 4,24 3,96 4,01 2,76 Energy Efficiency Class A A Heating Capacity (min/nom/max) 3 kw 8,90 20,4 27,4 10,2 26,1 33,5 Power input 3 kw 3,34 6,44 9,64 3,97 8,42 11,6 COP 3 kw/kw 2,66 3,17 2,84 2,57 3,10 2,89 Energy Efficiency Class B B Cooling Capacity (min/nom/max) 4 kw 6,60 20,0 25,2 9,43 29,0 31,1 Power input 4 kw 2,52 6,65 10,3 3,14 10,7 12,4 EER 4 kw/kw 2,62 3,01 2,45 3,00 2,71 2,51 Energy Efficiency Class B C EER 75% kw/kw 3,83 3,65 EER 50% kw/kw 4,53 4,48 EER 25% kw/kw 3,80 4,79 ESEER kw/kw 4,08 4,23 Part load steps % Stepless Power supply V/ph/Hz 400/3+N/50 Startup type Soft-start (inverter) Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Number / 1 / Scroll (BLDC Motor) Crankcase heater W 40 Evaporator Qty 1 Plate exchanger AISI 316 Water flow rate / pressure drop l/h / kpa Refer to hydraulic circuit data Antifreeze heater W 35 Fan Qty 2 2 Air flow m 3 /h 10.848 10.425 Power input kw 0,54 0,54 Pump Qty 1 1 Power input kw 0,56 0,63 Water flow rate / available static pressure l/h/kpa Refer to hydraulic circuit data Water Connections Male GAS Threaded Inlet/Outlet Diameter inch 1 1/4 Weight Shipping kg 266 281 Operating kg 260 275 Dimensions Lenght mm 1.477 1.477 Width mm 539 539 Height mm 1.615 1.615 Acoustical data Sound power level 5 db(a) 74 75 Sound pressure level 6 db(a) 43 44 1 Data refers to 35 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 2 Data refers to 18 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 3 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 4 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
88 Air cooled Chiller & Heat Pump Air Cooled Chiller & Heat Pump SyScroll 20-35 Air HP 20-33 kw 21-35 kw Air cooled Plate Scroll 410A Technical feature 4 sizes Cooling capacity from 20,2 to 33,4 kw Heating capacity from 20,9 to 35 kw One scroll compressor New control Operating low water content in the plant Pump as standard Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coils treatments Coil grilles Desuperheater Fan speed control (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water flow switch Water differential pressure switch (standard) Water filter (standard) SyScroll 20-35 Air HP - Cooling operation SyScroll 20-35 Air HP - Heating operation OAT ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Water + Glycol + EEV Water -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) OAT ( C) 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 LWT ( C) Operating limit (to be confirmed following selection software issue) SyScroll Air HP 20 25 30 35 Min - Max Leaving water temperature (cooling) * C from -8 to 18 T water (cooling mode) K 3-7 Leaving water temperature (heating) C +25 to +55 T water (heating mode) K 3-15 Air temperature C Refer to below graphichs * Below 5 C, glycol and electronic expansion valve is required. Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kw of output.
Technical feature Air cooled Chiller & Heat Pump 89 Air Cooled Chiller & Heat Pump SyScroll 20-35 Air HP 20 25 30 35 Cooling capacity 1 kw 20,2 23,9 27,4 33,4 Power input 1 kw 6,91 7,65 9,27 11,5 EER 100% 1 2,92 3,12 2,96 2,90 Energy Efficiency Class B A B B ESEER 3,34 3,61 3,50 3,40 Heating capacity 2 kw 20,9 24,5 28,4 35,0 Power input 2 kw 6,70 7,69 8,70 10,8 COP 2 3,12 3,19 3,26 3,24 Energy Efficiency Class B B A A Part load steps % 0-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty / 1 / Scroll Crankcase heater W 70 90 90 90 Internal heat exchanger Qty / 1 / Plate exchanger AISI 316 Summer operation Water flow l/s 0,95 1,12 1,29 1,57 Available Static Pressure kpa 172 154 148 116 Winter operation Water flow l/s 1,02 1,19 1,38 1,70 Available Static Pressure kpa 164 146 138 101 Antifreeze heater W 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 1 1/4 Water drain connection inch ⅜ Fan Qty / 2 / Axial Air flow m 3 /h 11.289 10.848 10.848 10.425 Power input kw 0,53 0,54 0,54 0,54 Pump Qty 1 1 1 1 Input Power (Summer / Winter) kw 0,57/0,58 0,60/0,61 0,62/0,63 0,65/0,66 Weight Shipping kg 256 287 291 305 Operating kg 250 281 286 299 Dimensions Lenght mm 1.477 1.477 1.477 1.477 Width mm 539 539 539 539 Height mm 1.615 1.615 1.615 1.615 Acoustical data Sound power level 3 db(a) 73 74 74 75 Sound pressure level at 10 m 4 db(a) 41 42 42 43 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
90 Air cooled Chiller & Heat Pump Air cooled heat pump SysAqua 25-40 H 25-37 kw Air cooled Scroll 27-40 kw Plate 410A Technical feature 4 sizes Cooling capacity from 25 to 37 kw Heating capacity from 27 to 40 kw EER up to 2,97 ESSEER up to 4 COP up to 3,04 SCOP up to 3,19 Refrigerant R410A Main functions Available with one cooling circuit Tandem scroll per refrigerant circuit Extented working limit Heat Pump operating function Leaving hot water up to 55 C Available versions Low sound level standard High temperature operation up to 50 C Return or leaving water temperature control With Hydraulic kit as STD Product Advantages Operating heating mode up to -15 C Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 l/kw Low footprint Easy maintenance Low water pressure drop Set point compensation as (standard) Night mode (extra low sound level) std ON OFF Remote Remote heat cool mode Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Main accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-15 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure as standard Rubber antivibration pad Water level pressure switch External water tank Operating limit (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) 5/18 C Leaving water temperature (with glycol max 40%) 2/18 C External Max air temperature 50 C External Min air temperature -10 C Heating mode Leaving water temperature max 55 C External Max air temperature +20 C External Min air temperature -15 C
Technical feature Air cooled Chiller & Heat Pump 91 Air Cooled Chiller & Heat Pump SysAqua 25-40 H 25 30 35 40 Cooling Capacity kw 25,3 26,9 35,8 37,4 Power input kw 8,6 9,3 13,5 13,6 Total EER 100% ** 2,94 2,88 2,71 2,70 ESEER ** 3,78 3,77 3,88 3,71 Heating Capacity kw 26,9 29,7 37,3 41,6 Power input kw 9,27 9,93 13,21 13,49 SCOP 3.19 3.16 3.03 3.17 SCOP Energy Efficiency Class A+ A+ A A+ Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Nominal current A 15,1 16,3 24 24 Maximum operating current A 22,5 24,5 32 34 Inrush current A 64 77.5 118.5 119.5 Refrigerant HFC 410A Number of refrigerant circuit 1 1 1 1 Compressor Qty 2 2 2 2 Scroll Scroll Scroll Scroll N capactity steps % 0/50/100 0/50/100 0/50/100 0/50/100 Cranckcrease heater W 2 X 40 2 X 70 2 X 70 2 X 70 Evaporator Qty 1 1 1 1 Plate Plate Plate Plate Water flow rate m³/h 4,3 4,6 6,1 6,3 Water pressure drop kpa 37 22 37 37 Water volume l 1,78 2,55 2,55 2,55 Antifreeze heater W 30 30 30 30 Coil Qty 1 1 1 1 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 Fan motors Qty 1 1 1 1 Air flow m³/h 13.000 13.000 16.000 16.000 Rotation speed tr/mn 900 900 650 650 Power input (unitary) W 940 940 930 930 Pumps Qty Option 2 pumps Power input kw Option 2 pumps Available static pressure Kpa Options 2 pumps Hydraulic Connection Male gas threaded Inlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Outlet diameter inch 1 1/2 1 1/2 1 1/2 1 1/2 Dimensions Length mm 1.000 1.000 1.000 1.000 Width mm 1.000 1.000 1.000 1.000 Height mm 1.983 1.983 1.983 1.983 Weight Operating kg 300 330 340 340 Acoustic data Sound power level * db(a) 75 75 76 76 * Following Eurovent standard. ** Following Eurovent 14511.
92 Air cooled Chiller & Heat Pump Air Cooled Heat Pump SyScroll 40-75 Air HP 37-72 kw Air cooled Scroll 39-76 kw Plate 410A Technical feature 6 sizes Cooling capacity from 36,8 to 71,6 kw Heating capacity from 39,2 to 76,3 kw 3 versions: STD (Standard version) HT (High Temperature) HPF (High Pressure Fans) 2 Low Noise versions: Standard version (STD) Super Low Noise (S) One refrigerant circuit 2 scroll compressors (one tandem) Low operating water content in the plant Polar version for extreme conditions Accessories and options Automatic circuit breaker Coils treatments Coil grilles (standard) Compressors acoustic box (standard on S) Compressors jackets (standard S) Desuperheater Electric heater inside buffer tank for additional heating Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter (standard) Water pressure switch (standard) Water flow switch (standard) Operating limit (to be confirmed following selection software issue) SyScroll 40-75 Air HP 40 45 50 60 65 75 Min - Max Leaving water temperature (cooling) * C from -8 to +18 Water T (cooling) K 3-7 Leaving water temperature (heating) C from +25 to +55 Water T (heating) K 3-15 Air temperature C Refers to following graphics * Below 5 C, glycol and electronic expansion valve are required. Chillers suitable for operation without buffer tank for water content greater than 2,5 liters of water per kw of output.
BLN Version Cooling Heating Air cooled Chiller & Heat Pump 93 Air Cooled Chiller & Heat Pump OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 Water + Glycol + EEV Water Water + Glycol + EEV + FSC Water + FSC -10-9-8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 10111213141516171819 20 LWT ( C) OAT ( C) 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 LWT ( C) S Version Cooling Heating OAT ( C) 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 Water + Glycol + EEV Water Water + Glycol + EEV + FSC Water + FSC -10-9 -8-7 -6-5 -4-3 -2-1 0 1 2 3 4 5 6 7 8 9 10 11121314151617181920 LWT ( C) OAT ( C) 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 LWT ( C) HT Version Cooling OAT ( C) OAT ( C) 55 50 55 45 50 40 45 35 40 30 35 25 30 20 25 15 20 10 Water + Glycol + EEV Water 155 100 Water + Glycol + EEV Water -55-100 -15-5 -10-20 -15-25 -20-10-9-8-7-6-5-4 -3-2-1 0 1 2 3 4 5 6 7 8 9 10111213141516171819 20-25 LWT ( C) -10-9 -8-7-6-5-4-3-2-1 0 1 2 3 4 5 6 7 8 9 10111213141516171819 20 40-50 60-75 40-50 60-75 LWT ( C) Heating OAT ( C) 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 LWT ( C)
94 Air cooled Chiller & Heat Pump Technical feature SyScroll 40-75 Air HP (STD-HPF-HT) 40 45 50 60 65 75 Cooling capacity 1 kw 36,8 41,7 48,4 56,8 64,3 71,6 Power input 1 kw 13,6 15,6 18,1 19,9 22,8 27,1 EER 1 2,71 2,67 2,67 2,85 2,82 2,64 Energy Efficiency Class C D D C C D ESEER 3,81 3,74 3,72 3,82 3,75 3,57 Heating capacity 2 kw 39,2 43,7 51,7 58,0 69,1 76,3 Power input 2 kw 13,3 14,5 16,3 21,3 23,0 26,9 COP 2 2,95 3,01 3,17 2,72 3,00 2,84 Energy Efficiency Class C B B C B C Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 2 2 2 2 2 2 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.209 7.052 8.170 9.615 10.888 12.160 Antifreeze heater W 35 35 35 35 35 35 Connection type Male gas threaded Inlet/outlet diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 14.800 14.800 14.800 22.250 22.250 22.250 Speed rpm/min 680 680 680 900 900 900 Power Input kw 0,98 0,98 0,98 2,00 2,00 2,00 Power Input * kw 2,67 2,67 2,67 2,67 2,67 2,67 Available static pressure * Pa from 0 to 120 Weight Shipping kg 422 430 457 504 511 517 Operating kg 431 440 467 517 524 530 Dimensions Length mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 3 db(a) 78 79 79 83 84 84 Sound pressure level 4 db(a) 47 47 47 52 52 52 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * HPF / HT versions with EC fan motor.
Technical feature Air cooled Chiller & Heat Pump 95 Air Cooled Chiller & Heat Pump SyScroll 40-75 Air HP S 40 45 50 60 65 75 Cooling capacity 1 kw 36,8 40,2 46,3 55,0 59,8 68,9 Power input 1 kw 13,9 16,1 18,9 20,1 22,9 28,0 EER 1 2,65 2,50 2,45 2,74 2,61 2,46 Energy Efficiency Class D D E C D E ESEER 3,61 3,50 3,42 3,67 3,47 3,35 Heating capacity 2 kw 38,2 42,5 50,4 56,6 67,3 74,4 Power input 2 kw 13,0 14,2 16,1 20,8 22,5 26,4 COP 2 2,94 2,99 3,13 2,72 2,99 2,82 Energy Efficiency Class C C B C C C Number of refrigerant circuits 1 1 1 1 1 1 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct Refrigerant HFC 410A Compressor Qty 2 2 2 2 2 2 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 6.209 6.794 7.809 9.305 10.114 11.679 Antifreeze heater W 35 35 35 35 35 35 Connection type Male gas threaded Inlet/outlet Diameter inch 2 2 2 2 2 2 Water drain connection inch ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Condenser Qty 1 1 1 1 1 1 Total coil face area per coil mm 2,6 2,6 2,6 3,2 3,2 3,2 Fan Qty 1 1 1 1 1 1 Air flow m 3 /h 11.500 11.500 10.800 17.000 17.000 17.000 Speed rpm/min 530 530 530 720 720 720 Power Input kw 0,57 0,57 0,57 1,27 1,27 1,27 Weight Shipping kg 422 430 457 504 511 517 Operating kg 431 440 467 517 524 530 Dimensions Length mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 3 db(a) 74 75 75 78 79 79 Sound pressure level 4 db(a) 42 44 44 46 47 47 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
96 Air cooled Chiller & Heat Pump Air Cooled Heat Pump SysAqua 45-125 Air H 46.8-121.9 kw Air cooled Scroll 50-120 kw Plate 410A Technical feature 7 sizes Cooling capacity from 46 to 12 kw Heating capacity from 50 to 120 kw Refrigerant R410A EER up to 3 ESSEER up to 4 COP up to 3.12 SCOP up to 3,31 Main functions Available with one cooling circuit Tandem scroll for refrigerant circuit Extented operating limits Heat Pump operating function Leaving hot water up to 55 C Available versions Low sound level standard High temperature operation up to 50 C Return or leaving water temperature control With or without Hydraulic kit Product Advantages Operating heating mode up to -15 C Tandem scroll compressors per circuit for a highest efficiency at partial load High ESEER ILTC II Controller that allows to reduce the use of an external water tank 3,5 l/kw Low footprint Easy maintenance Low water pressure drop Set point compensation as (standard) Night mode (extra low sound level) std ON-OFF Remote Remote heat cool mode Water flow switch factory mounted (standard) Water filter (standard) (not mounted) Phase monitor (standard) Few options, maximum features as (standard) Main accessories and options HP/BP Manometers Kit interface modbus Low temperature kit (-15 C) Compressor softstarter Power supply without neutral Aluminium fins with epoxy coating Condenser coil guards Complete Hydraulic kit 1 pump medium pressure Rubber antivibration pad Water level pressure switch Water tank 300lt Complete Hydraulik kit 2 pumps medium pressure High pressure Fan Operating limit (to be confirmed following selection software issue) Cooling mode Leaving water temperature (without glycol) 5/18 C Leaving water temperature (with glycol max 40%) 2/18 C External Max air temperature 50 C External Min air temperature -10 C Heating mode Leaving water temperature max 55 C External Max air temperature +20 C External Min air temperature -15 C
Technical feature Air cooled Chiller & Heat Pump 97 Air Cooled Chiller & Heat Pump SysAqua 45-125 Air H 45 55 65 75 90 105 125 Cooling Capacity kw 46,8 53,3 65,8 71,6 91,4 106,0 122 Power input kw 16,89 19,66 22,1 23,8 34,36 38,0 46,4 Total EER 100% ** 2,77 2,71 2,97 3 2,66 2,79 2,63 ESEER ** 3,87 3,89 4 3,97 3,82 3,85 3,83 Heating Capacity kw 50 58,4 69,6 75,9 88 101,0 119 Power input kw 17,85 20,42 22,7 24,3 33,72 38,4 45,4 SCOP 2.99 3.07 3.30 3.23 3.24 3.26 3.31 SCOP Energy Efficiency Class A A A+ A+ A+ A+ A+ Power supply 400V/3~+N/50Hz Start up type Direct Direct Direct Direct Direct Direct Direct Nominal current A 30 35 42 47 62 69 84 Maximum operating current A 41 45 59.5 64.5 79.5 87.5 103.5 Inrush current A 134 141 205.5 206.5 266.5 313.5 351.5 Refrigerant R410A Number of refrigerant circuit 1 1 1 1 1 1 1 Compressors Qty 2 2 2 2 2 2 2 Scroll Scroll Scroll Scroll Scroll Scroll Scroll N capactity steps % 0/45/ 55/100 0/40/ 60/100 0/40/ 60/100 0/45/ 55/100 0/45/ 55/100 0/40/ 60/100 0/33/ 67/100 Cranckcrease heater W 2 * 90 2 * 90 2 * 90 2 * 90 90/120 90/140 90/140 Evaporator Qty 1 1 1 1 1 1 1 Plates Plates Plates Plates Plates Plates Plates Water flow rate m³/h 8 9,1 11,3 12,3 15,7 18,2 20,9 Water pressure drop kpa 27 35 28 33 26 34 45 Water volume l 4,1 4,1 6,1 6,1 10,8 10,8 10,8 Antifreeze heater W 30 30 2 * 30 2 * 30 2,30 2 * 30 2 * 30 Coil Qty 1 1 2 2 2 2 2 Total coil face area per coil m 2 4,2 4,2 5,55 5,55 6,4 6,4 6,4 Fan motors Qty 1 1 2 2 2 2 2 Air flow m³/h 23.500 23.500 30.000 30.000 42.000 42.000 42.000 Power input (unitary) W 1.800 1.800 800 800 1.800 1.800 1.800 Pumps Qty Option 1 or 2 Pumps Power input kw Option 1 or 2 Pumps Available static pressure Kpa Option 1 or 2 Pumps Hydraulic Connection Male GAS Threaded Inlet Diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Outlet diameter inch 2 2 2 2 2 1/2 2 1/2 2 1/2 Dimensions Length mm 2.180 2.180 2.180 2.180 2.180 2.180 2.180 Width mm 1.160 1.160 1.160 1.160 1.160 1.160 1.160 Height mm 1.986 1.986 1.986 1.986 2.286 2.286 2.286 Weight Operating kg 510 510 580 580 890 1.000 1.020 Acoustical data Sound power level * db(a) 79 79 79 79 82 82 82 * Following Eurovent standard. ** Following Eurovent 14511.
98 Air cooled Chiller & Heat Pump Air Cooled Heat Pump SyScroll 85-135 Air HP 79-152 kw Air cooled Scroll 85-133 kw Plate 410A Technical feature 5 sizes Cooling capacity from 79,0 to 125,0 kw Heating capacity from 85,0 to 132,6 kw 3 versions: STD (Standard versions) HT (High Temperature version) HPF (High Pressure Fans version) 2 acoustic versions: Standard version (STD) Extra Low Noise version (S) One refrigerant circuit 2 Scroll compressors ( tandem) Microprocessor control Electronic expansion valve as standard Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard) Compressors jackets Coils treatments Desuperheater Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water flow switch (standard) Water pressure switch Water filter
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 99 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air HP Leaving water temperature (cooling) Leaving water temperature (heating) Air temperature (cooling) Air temperature (heating) External static pressure 85-135 Min Max Water С +6 +18 Water with glycol + electonic expansion valve* С -8 +6 T К 3 7 Water С +20 +52 T К 3 7 BLN С +5 +42 S С -14 +40 HT С -18 +44 BLN С -10 +20 S С -10 +20 HT С -12 +20 Standard Fans Pa 0 High Pressure Fans (HPF) Pa < 120 Std Version - Cooling S Version - Cooling OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 1012141618 LWT ( C) OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 1012 1416 18 LWT ( C) HT Version - Cooling OAT ( C) 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) Heating OAT ( C) 25 20 15 10 5 0-5 -10 HT Version -15-20 15 20 25 30 35 40 45 50 55 60 LWT ( C)
100 Air cooled Chiller & Heat Pump Technical feature SyScroll 85-135 Air HP 85 95 105 120 135 Cooling capacity 1 kw 79,0 87,0 98,0 113,8 125,0 Power input 1 kw 27,6 32,0 39,0 42,0 47,0 EER 1 2,86 2,72 2,51 2,71 2,66 Energy efficiency class C C D C D ESEER 3,84 4,22 3,75 3,98 4,00 Heating capacity 2 kw 85,0 96,0 107,0 120,0 132,6 Power input 2 kw 27,1 30,8 38,0 42,5 47,2 COP 2 3,14 3,12 2,82 2,82 2,81 Energy efficiency class B B C C C Part load steps % 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 13,6 15,0 16,9 19,6 21,5 Water pressure drop kpa 24 29 25 21 17 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil mm 2,4 3,1 Fan Qty 2 Air flow rate m 3 /h 34.700 42.000 43.200 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 3 db(a) 84 84 88 88 88 Sound pressure level 4 db(a) 52 52 56 56 56 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 101 Air Cooled Chiller & Heat Pump SyScroll 85-135 Air HP S 85 95 105 120 135 Cooling capacity 1 kw 76,0 83,3 95,0 111,4 121,8 Power input 1 kw 28,3 33,3 40,0 42,6 48,0 EER 1 2,68 2,50 2,37 2,62 2,54 Energy efficiency class D E E D D ESEER 3,73 4,10 3,68 3,74 3,88 Heating capacity 2 kw 82,6 93,1 105,1 117,8 129,4 Power input 2 kw 26,4 30,1 37,0 41,5 46,2 COP 2 3,13 3,09 2,84 2,84 2,80 Energy efficiency class B B C C C Part load steps % 0-50-100 0-43-100 0-50-100 0-44-100 0-50-100 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Internal heat exchanger Qty 1 Plate Water flow rate m 3 /h 13,1 14,3 16,3 19,2 20,9 Water pressure drop kpa 22 26 24 20 17 Antifreeze heater W 130 External heat exchanger Qty 2 Total coil face area per coil mm 2,4 3,1 Fan Qty 2 Air flow rate m 3 /h 26.200 34.700 35.800 Water connections Male GAS Threaded Inlet diameter inch 2 1/2 Outlet diameter inch 2 1/2 Dimensions Lenght mm 3.000 3.500 Width mm 1.100 1.100 Height mm 2.250 2.250 Acoustic data Sound power level 3 db(a) 82 82 85 85 85 Sound pressure level 4 db(a) 50 50 53 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
102 Air cooled Chiller & Heat Pump Air Cooled Heat Pump AQVH 85-140 81-130 kw Air cooled Scroll 87-144 kw Plate 410A Technical feature 6 sizes Cooling capacity from 81,0 to 129,6 kw Heating capacity from 87,0 to 143,6 kw 4 versions: STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions: BLN (Basic Low Noise) ELN (Extra Low Noise) Two refrigerant circuit Scroll compressors Microprocessor control Low operating water content in the plant Electronic expansion valve as standard Polar version for extreme conditions Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater Double set point Electric heater inside buffer tank for additional heating Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Pressure switch Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch (standard) Operating limit (to be confirmed following selection software issue) AQVH 85-140 Min Max Leaving water temperature (cooling) Water С +5 +18 Water with glycol С -8 +18 Leaving water temperature (heating) С +20 +55 Air temperature (heating) С -10 +20 Air temperature (heating) Polar Version C -15 +20 Air temperature (cooling) External static pressure BLN С +5 +47 ELN С -18 +44 HT С -18 Standard fans Pa 0 High Pressure Fans (HPF) Pa < 120 +50 ( 85-115) +47 (125-140)
Technical feature Air cooled Chiller & Heat Pump 103 Air Cooled Chiller & Heat Pump AQVH 85-140 BLN 85 95 105 115 125 140 Cooling capacity 1 kw 81,0 89,9 98,9 106,7 115,6 129,6 Power input 1 kw 27,5 31,5 34,2 36,8 41,6 46,6 EER 1 2,95 2,85 2,89 2,90 2,78 2,78 Energy efficiency class B C B C C C ESEER 3,78 3,81 3,86 3,96 3,69 3,77 EER HSE 1 3,05 2,94 2,97 2,96 2,84 2,84 Energy efficiency class B B B B C C ESEER HSE 1 4,21 4,14 4,27 4,28 3,96 4,03 Heating capacity 2 kw 87,0 100,4 108,3 116,4 131,5 143,6 Power input 2 kw 25,7 31,1 32,9 35,7 42,0 45,7 COP 2 3,39 3,23 3,29 3,26 3,13 3,14 Energy efficiency class A A A A B B COP HSE 2 3,54 3,47 3,52 3,47 3,36 3,36 Energy efficiency class A A A A A A Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 13.967 15.508 17.060 18.431 19.987 22.288 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Total coil face area per coil mm 2,4 2,4 2,4 2,4 3,1 3,1 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 34.700 34.700 34.050 33.400 44.500 43.200 Speed rpm/min 690 690 690 690 900 900 Power input kw 2,1 2,1 2,1 2,1 3,4 3,4 Weight Shipping kg 1.065 1.080 1.122 1.153 1.196 1.270 Operating kg 1.090 1.105 1.149 1.180 1.227 1.301 Dimension Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 3 db(a) 84 84 84 84 88 88 Sound pressure level 4 db(a) 52 52 52 52 56 56 Sound power level HPF 3 db(a) 92 92 92 92 95 95 Sound pressure level HPF 4 db(a) 60 60 60 60 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
104 Air cooled Chiller & Heat Pump Technical feature AQVH 85-140 ELN 85 95 105 115 125 140 Cooling capacity 1 kw 78,3 86,5 94,8 102,7 112,7 124,6 Power input 1 kw 28,7 33,3 36,2 39,4 43,5 47,6 EER 1 2,73 2,60 2,62 2,61 2,59 2,62 Energy Efficiency class C D D D D D ESEER 3,57 3,57 3,61 3,52 3,50 3,59 EER HSE 1 2,84 2,70 2,71 2,69 2,65 2,67 Energy Efficiency class C C C D D D ESEER HSE 1 4,07 3,94 3,94 3,97 3,72 3,85 Heating capacity 2 kw 85,2 97,8 105,3 113,4 127,4 139,5 Power input 2 kw 25,3 30,6 32,5 35,4 40,1 44,0 COP 2 3,37 3,20 3,24 3,20 3,18 3,17 Energy Efficiency class A A A A B B COP HSE 2 3,55 3,46 3,50 3,45 3,38 3,38 Energy Efficiency class A A A A A A Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 13.496 14.924 16.355 17.632 19.349 21.508 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 25.800 25.800 25.300 24.800 36.900 35.800 Speed rpm/min 500 500 500 500 690 690 Power input kw 1,8 1,8 1,8 1,8 2,1 2,1 Weight Shipping kg 1.095 1.110 1.152 1.183 1.226 1.300 Operating kg 1.120 1.135 1.179 1.210 1.257 1.331 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 3 db(a) 82 82 82 82 86 86 Sound pressure level 4 db(a) 50 50 50 50 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 105 Air Cooled Chiller & Heat Pump AQVH 85-140 HT 85 95 105 115 125 140 Cooling capacity 1 kw 83,6 93,4 103,8 111,7 118,0 132,1 Power input 2 kw 23,6 27,2 29,5 32,0 37,0 41,2 EER 2,96 2,94 3,04 3,05 2,83 2,88 ESEER 4,14 4,12 4,25 4,27 3,97 4,03 Heating capacity 3 kw 93,5 104,9 113,7 121,9 135,6 148,3 Power input 2 kw 24,5 28,1 30,1 32,8 37,2 40,9 COP 3,22 3,21 3,28 3,26 3,25 3,26 Part load steps % 0-25-50-75-100 0-25-50-75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50-75-100 0-22-43-72-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 Scroll Crankcase heater W 90 90 90 90 90 90 Evaporator Qty 1 1 1 1 1 1 Plate exchanger AISI 316 Water flow l/h 14.371 16.073 17.847 19.219 20.291 22.718 Antifreeze heater W 130 130 130 130 130 130 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ Condenser Qty 2 2 2 2 2 2 Fan Qty 2 2 2 2 2 2 Air flow m 3 /h 50.700 50.700 49.700 48.700 52.700 51.700 Speed rpm/min 1.130 1.130 1.130 1.130 1.130 1.130 Power input kw 4,6 4,6 4,6 4,6 4,6 4,6 Weight Shipping kg 1.065 1.080 1.122 1.153 1.196 1.270 Operating kg 1.090 1.105 1.149 1.180 1.227 1.301 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 4 db(a) 95 95 95 95 95 95 Sound pressure level 5 db(a) 63 63 63 63 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
106 Air cooled Chiller & Heat Pump Air Cooled Heat Pump SyScroll 140-360 Air EVO HP 137-340 kw Air cooled Scroll 145-361 kw Plate 410A ENERGY EFFICIENCY COOLING MODE 2014 Technical feature 9 sizes Cooling capacity from 136,7 to 340,5 kw Heating capacity from 144,9 to 361,4 kw Fans versions: STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans) Acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Polar version: Heat Pump for extreme conditions Two refrigerant circuits 4 Scroll compressors Electronic expansion valve Report to performance data Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater Fan speed control (standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank (350lt 140-170, 500lt 200-360) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 107 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air EVO HP 140 170 200 230 Min Max Min Max Min Max Min Max Water C +5 to +18 Temperatura Chilled Water with glycol uscita liquido C -10 to +5 liquid Temperature spread K 3 to 7 Maximum operating pressure bar 6 Liquid outlet Acqua C +20 to +55 Warmed temperature ΔT K 3 to 7 Liquid Maximum operating pressure bar 6 - / L / S / EC C -10 to +20 Ambient Air entering air temp. Heating Versione Polar C -13 to +20 HT C -13 to +20 Air entering - / L / S C +5 to +48 / +0 to +46 / -14 to +44 Ambient temp. Cooling EC-HT C -18 to +50 air External Standard fans Pa 0 static pressure High pressure fans Pa <120 Recommended system chilled water volume 1 l 420 510 600 690 Minimum capacity step % 25 25 21 19 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) SyScroll 140-360 Air EVO HP 260 280 300 330 360 Min Max Min Max Min Max Min Max Min Max Water C +5 to +18 Temperatura Chilled Water with glycol uscita liquido C -10 to +5 liquid Temperature spread K 3 to 7 Maximum operating pressure bar 6 Liquid outlet Acqua C +20 to +55 Warmed temperature ΔT K 3 to 7 Liquid Maximum operating pressure bar 6 - / L / S / EC C -10 to +20 Ambient Air entering air temp. Heating Versione Polar C -13 to +20 HT C -13 to +20 Air entering - / L / S C +5 to +48 / +0 to +46 / -14 to +44 Ambient temp. Cooling EC-HT C -18 to +50 air External Standard fans Pa 0 static pressure High pressure fans Pa <120 Recommended system chilled water volume 1 l 780 840 900 990 1080 Minimum capacity step % 17 16 24 23 25 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) * For Liquid outlet temperature <0 C provide Brine Version (on request for HP). 1 Table shows minimum water / brine volume of system (about 3 lt/kw). 2 Voltage 400V +/- 10%. Heating mode (Cooling mode see page 35) 25 20 15 10 OAT ( C) 5 0-5 -10-15 HT-Polar Version -20 15 20 25 30 35 40 45 50 55 60 LWT ( C)
108 Air cooled Chiller & Heat Pump Technical feature SyScroll 140-360 Air Evo HP (STD-EC-HPF) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 136,7 154,5 181,3 213,6 243,7 261,1 287,8 307,4 340,5 Input power 1 kw 45,1 54,6 61,9 73,2 83,8 90,7 98,5 103,5 117,0 EER 1 3,03 2,83 2,93 2,92 2,91 2,88 2,92 2,97 2,91 Energy efficiency class B C B B B C B B B ESEER 3,52 3,47 3,60 3,71 3,71 3,65 3,60 3,64 3,65 EER * 3,08 2,86 2,97 2,96 2,95 2,91 2,96 3,02 2,95 ESEER * 3,62 3,57 3,71 3,83 3,83 3,78 3,71 3,71 3,76 EER ** 2,86 2,69 2,73 2,75 2,73 2,71 2,75 2,78 2,74 ESEER ** 3,38 3,30 3,46 3,56 3,60 3,51 3,46 3,57 3,51 Nominal heating capacity 2 kw 144,9 165,7 200,1 229,0 262,3 279,6 305,6 327,2 361,4 Input power 2 kw 44,9 51,6 62,1 70,9 81,7 87,4 94,9 101,9 112,6 COP 2 3,23 3,21 3,22 3,23 3,21 3,20 3,22 3,21 3,21 Energy efficiency class A A A A A A A A A COP * 3,28 3,25 3,28 3,27 3,26 3,25 3,27 3,26 3,26 COP ** 3,05 3,05 3,01 3,03 3,01 3,02 3,02 2,99 3,02 Nominal heating capacity 3 kw 148,6 170,0 207,0 233,8 268,4 285,6 311,0 333,9 367,9 Input power 3 kw 37,2 43,6 52,7 58,7 67,8 72,3 77,8 83,7 92,7 COP 3 4,00 3,90 3,93 3,98 3,96 3,95 4,00 3,99 3,97 Total capacity steps % 25-50- 25-50- 21-43- 19-38- 17-39- 16-37- 24-48- 23-50- 25-50- 75-100 75-100 71-100 69-100 67-100 68-100 71-100 73-100 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow cooling m 3 /h 23,6 26,7 31,3 36,9 42,1 45,1 49,6 53,0 58,8 Water pressure drop cooling kpa 25 31 34 30 30 35 26 30 37 Water flow heating 2 m 3 /h 24,8 28,4 34,3 39,3 45,0 47,9 52,4 56,1 62,0 Water pressure drop heating 2 kpa 27 36 41 34 34 39 29 33 41 Water flow heating 3 m 3 /h 25,5 29,1 35,5 40,1 46,0 48,9 53,3 57,3 63,1 Water pressure drop heating 3 kpa 29 37 44 36 36 41 30 35 42 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze Heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 900 900 900 900 900 900 900 900 900 Total airflow m 3 /h 68.400 68.400 112.500 112.500 135.000 135.000 157.500 180.000 180.000 Total input power kw 5,1 5,1 8,5 8,5 10,2 10,2 11,9 13,6 13,6 Total input power * kw 4,5 4,5 7,5 7,5 9,0 9,0 10,5 12,0 12,0 Total input power ** kw 7,8 7,8 13,0 13,0 15,6 15,6 18,2 20,8 20,8 External static pressure Pa 0 or 120 Pa ** Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.294 1.337 1.843 1.967 2.188 2.198 2.767 2.860 2.870 Operating kg 1.312 1.355 1.858 1.993 2.216 2.226 2.806 2.899 2.909 Additional weight EC-HPF versions kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 4 db(a) 90 90 92 92 93 93 94 95 95 Sound pressure level 10 m 5 db(a) 47 47 50 50 51 51 53 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans. ** HPF Units with high static pressure fans.
Technical feature Air cooled Chiller & Heat Pump 109 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air Evo HP L (STD-EC) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 132,9 149,3 176,9 207,2 236,9 253,3 279,4 299,1 330,1 Input power 1 kw 45,2 55,3 61,2 73,7 83,7 91,4 99,1 103,1 117,5 EER 1 2,94 2,70 2,89 2,81 2,83 2,77 2,82 2,90 2,81 Energy efficiency class B C C C C C C C C ESEER 3,59 3,55 3,67 3,78 3,76 3,72 3,67 3,67 3,72 EER * 2,98 2,73 2,93 2,85 2,87 2,81 2,86 2,94 2,84 Energy efficiency class * B C B C C C C B C ESEER * 3,69 3,66 3,78 3,91 3,89 3,85 3,78 3,75 3,83 Nominal heating capacity 2 kw 141,0 162,1 193,7 223,7 255,6 272,3 299,4 320,8 353,9 Input power 2 kw 43,5 50,3 60,0 69,0 79,4 84,8 92,7 99,6 109,9 COP 2 3,24 3,22 3,23 3,24 3,22 3,21 3,23 3,22 3,22 Energy efficiency class A A A A A A A A A Nominal heating capacity 3 kw 144,2 165,8 199,8 227,8 260,8 277,3 303,8 326,4 359,2 Input power 3 kw 35,8 42,2 50,5 56,5 65,2 69,8 75,2 81,0 89,8 COP 3 4,03 3,93 3,96 4,03 4,00 3,97 4,04 4,03 4,00 COP * 3,32 3,30 3,32 3,32 3,31 3,29 3,31 3,31 3,30 Total capacity steps % 25-50- 25-50- 21-43- 19-38- 17-39- 16-37- 24-48- 23-50- 25-50- 75-100 75-100 71-100 69-100 67-100 68-100 71-100 73-100 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow cooling m 3 /h 22,9 25,8 30,5 35,7 40,9 43,7 48,2 51,6 57,0 Water pressure drop cooling kpa 23 29 33 28 28 33 25 28 34 Water flow heating 2 m 3 /h 24,2 27,8 33,2 38,4 43,8 46,7 51,4 55,0 60,7 Water pressure drop heating 2 kpa 26 34 39 33 33 37 28 32 39 Water flow heating 3 m 3 /h 24,7 28,4 34,2 39,0 44,7 47,5 52,1 56,0 61,6 Water pressure drop heating 3 kpa 27 36 41 34 34 39 29 33 40 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 700 700 700 700 700 700 700 700 700 Total airflow m 3 /h 55.000 55.000 92.500 92.500 111.000 111.000 129.500 148.000 148.000 Total input power kw 3,6 3,6 6,0 6,0 7,2 7,2 8,4 9,6 9,6 Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter inch 1 1 1 1 1 1 1 1 1 Outlet diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.294 1.337 1.843 1.967 2.188 2.198 2.767 2.860 2.870 Operating kg 1.312 1.355 1.858 1.993 2.216 2.226 2.806 2.899 2.909 Additional weight EC version kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 4 db(a) 85 85 87 87 88 88 89 90 90 Sound pressure level 10 m 5 db(a) 58 58 60 60 61 61 62 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans.
110 Air cooled Chiller & Heat Pump Technical feature SyScroll 140-360 Air Evo HP S (STD-EC) 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 125,9 140,3 168,5 194,7 224,0 238,5 263,3 283,5 310,5 Input power 1 kw 47,2 57,7 63,4 77,6 88,2 96,6 104,5 108,2 124,2 EER 1 2,67 2,43 2,66 2,51 2,54 2,47 2,52 2,62 2,50 Energy efficiency class D D D D D D D D D ESEER 3,66 3,64 3,75 3,85 3,82 3,80 3,75 3,71 3,80 EER * 2,71 2,45 2,70 2,54 2,58 2,50 2,55 2,66 2,53 Energy efficiency class * C D C D D D D D D ESEER * 3,77 3,75 3,86 3,99 3,95 3,93 3,86 3,79 3,91 Nominal heating capacity 2 kw 138,5 159,5 189,8 219,8 250,8 267,1 294,7 315,0 348,9 Input power 2 kw 42,4 48,9 58,0 67,2 77,2 82,4 90,4 96,9 107,4 COP 2 3,27 3,26 3,27 3,27 3,25 3,24 3,26 3,25 3,25 Energy efficiency class A A A A A A A A A Nominal heating capacity 3 kw 141,3 162,7 195,3 223,3 255,3 271,3 298,3 319,7 353,2 Input power 3 kw 34,9 41,1 49,1 55,1 63,5 67,8 73,5 78,9 87,6 COP 3 4,05 3,96 3,98 4,05 4,02 4,00 4,06 4,05 4,03 Total capacity steps % 25-50- 75-100 25-50- 75-100 21-43- 71-100 19-38- 69-100 17-39- 67-100 16-37- 68-100 24-48- 71-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow cooling m 3 /h 21,7 24,2 29,1 33,6 38,6 41,1 45,4 48,9 53,6 Water pressure drop cooling kpa 21 26 30 25 25 29 22 25 30,3 Water flow heating 2 m 3 /h 23,8 27,3 32,5 37,7 43,0 45,8 50,6 54,0 59,8 Water pressure drop heating 2 kpa 25 33 37 32 32 36 27 31 38 Water flow heating 3 m 3 /h 24,2 27,9 33,5 38,3 43,8 46,5 51,2 54,8 60,5 Water pressure drop heating 3 kpa 26 34 39 33 33 37 28 32 39 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 2 2 5 5 6 6 7 8 8 Total coil face area per coil m 2 4,6 4,6 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 550 550 550 550 550 550 550 550 550 Total airflow m 3 /h 44.000 44.000 72.500 72.500 87.000 87.000 101.500 116.000 116.000 Total input power kw 2,7 2,7 4,5 4,5 5,4 5,4 6,3 7,2 7,2 Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter inch 1 1 1 1 1 1 1 1 1 Outlet diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.299 1.342 1.848 1.972 2.193 2.203 2.772 2.865 2.875 Operating kg 1.317 1.360 1.863 1.998 2.221 2.231 2.811 2.904 2.914 Additional weight EC version kg 30 30 50 50 60 60 70 80 80 With desuperheater kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 4 db(a) 79 79 82 82 83 83 85 86 86 Sound pressure level 10 m 5 db(a) 53 53 55 55 56 56 57 58 58 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans.
Technical feature Air cooled Chiller & Heat Pump 111 Air Cooled Chiller & Heat Pump SyScroll 140-360 Air Evo HP HT 140 170 200 230 260 280 300 330 360 Nominal cooling capacity 1 kw 137,9 156,0 182,5 215,5 245,8 263,4 290,3 309,8 343,4 Input power 3 kw 39,0 48,4 52,3 63,2 71,9 78,6 84,9 88,0 101,0 EER 2,92 2,75 2,77 2,80 2,78 2,77 2,80 2,82 2,79 Energy efficiency class B C C C C C C C C ESEER 3,45 3,38 3,53 3,63 3,65 3,58 3,53 3,60 3,58 Nominal heating capacity 2 kw 147,0 168,5 202,8 232,3 266,0 283,7 309,8 331,5 366,5 Input power 3 kw 39,2 46,0 52,8 61,8 70,7 76,1 82,3 87,1 97,8 COP 3,11 3,12 3,07 3,10 3,07 3,08 3,08 3,06 3,08 Energy efficiency class B B B B B B B B B Total capacity steps % 25-50- 25-50- 21-43- 19-38- 17-39- 16-37- 24-48- 23-50- 25-50- 75-100 75-100 71-100 69-100 67-100 68-100 71-100 73-100 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 Compressor Qty 4 4 4 4 4 4 4 4 4 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 Plate Water flow cooling m 3 /h 23,8 26,9 31,5 37,2 42,4 45,5 50,1 53,4 59,3 Water pressure drop cooling kpa 25 32 35 31 31 35 26 30 37 Water flow heating 2 m 3 /h 25,2 28,9 34,7 39,8 45,6 48,6 53,1 56,8 62,8 Water pressure drop heating 2 kpa 28 37 42 35 35 40 30 34 42 Water flow heating 6 m 3 /h 25,9 29,7 36,0 40,8 46,8 49,8 54,2 58,1 64,1 Water pressure drop heating 6 kpa 30 39 45 37 37 42 31 36 43 Water volume l 11,4 11,4 13 21,1 23,4 23,4 32,4 32,4 32,4 Antifreeze Heater W 130 130 130 130+130 130+130 130+130 130 130 130 Air cooled condenser Qty 5 5 5 6 6 6 7 8 8 Total coil face area per coil m 2 12 12 12 14,4 14,4 14,4 16,8 19,2 19,2 Fan Qty 3 3 5 5 6 6 7 8 8 Nominal speed rpm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Total airflow m 3 /h 80.500 80.500 132.500 132.500 159.000 159.000 185.500 212.000 212.000 Total input power * kw 7,8 7,8 13,0 13,0 15,6 15,6 18,2 20,8 20,8 Water Connections (Evaporator) Male GAS Threaded Inlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Outlet diameter inch 2 1/2 2 1/2 2 1/2 3 3 3 3 3 3 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter inch 1 1 1 1 1 1 1 1 1 Outlet diameter inch 1 1 1 1 1 1 1 1 1 Weight Shipping kg 1.324 1.367 1.893 2.017 2.248 2.258 2.837 2.940 2.950 Operating kg 1.342 1.385 1.908 2.043 2.276 2.286 2.876 2.979 2.989 Additional weight Desuperheater versions kg 8,5 8,5 17 17 19 19 23 23 23 With one pump kg 45 45 45 55 55 55 65 65 65 With two pumps kg 95 95 95 115 115 115 140 140 140 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 4 db(a) 92 92 94 94 96 96 97 98 98 Sound pressure level 10 m 5 db(a) 60 60 62 62 64 64 65 66 66 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Input power (only compressors). 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * High Efficiency Units (EC) with inverter fans.
112 Air cooled Chiller & Heat Pump Air Cooled Heat Pump SyScroll 240-660 Air HP 217-581 kw Air cooled Scroll 256-679 kw Plate 410A Technical feature 10 sizes Cooling capacity from 216,5 to 580,6 kw Heating capacity from 255,9 to 679,1 kw Fans versions: STD (Standard) HT (High Temperature) HPF (High Pressure Fans) Acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits 3/4/5/6 Scroll compressors Electronic expansion valve Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater Fan speed control (standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 113 Air Cooled Chiller & Heat Pump SyScroll 240-360 Air HP 240 270 290 320 360 Min Max Min Max Min Max Min Max Min Max Water C +6 to +18 Liquid outlet Chilled Water with glycol temperature C -10 to +6 liquid ΔT K 3 to 7 Maximum operating pressure bar 6 - C +5 to +42 +5 to +42 +5 to +42 +5 to +42 +5 to +42 Air entering L C +5 to +40 +5 to +40 +5 to +40 +5 to +40 +5 to +40 temperature Ambient Cooling S C -14 to +40-14 to +40-14 to +40-14 to +40-14 to +40 air HT-HPF C -18 to +44-18 to +44-18 to +44-18 to +44-18 to +44 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 960 1.080 1.160 1.280 1.080 Minimum capacity step % 31 33 30 27 23 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) SyScroll 420-660 Air HP 420 470 540 590 660 Min Max Min Max Min Max Min Max Min Max Water C +6 to +18 Liquid outlet Chilled Water with glycol temperature C -10 to +6 liquid ΔT K 3 to 7 Maximum operating pressure bar 6 - C +5 to +42 +5 to +42 +5 to +42 +5 to +42 +5 to +42 Air entering L C +5 to +40 +5 to +40 +5 to +40 +5 to +40 +5 to +40 temperature Ambient Cooling S C -14 to +40-14 to +40-14 to +40-14 to +40-14 to +40 air HT-HPF C -18 to +44-18 to +44-18 to +44-18 to +44-18 to +44 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 1.260 1.128 1.296 1.180 1.320 Minimum capacity step % 25 24 20 14 17 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) * For Liquid outlet temperature <0 C provide Brine Version (available for CO; on request for HP). 1 Table shows minimum water / brine volume of system (about 3 lt/kw). 2 Voltage 400V +/- 10%. - Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol + FSC Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) L Version OAT ( C) OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Brine Version * + Water + Glycol Brine Version * + Water + Glycol Water + Glycol Water + Glycol + FSC Water Water + FSC -12-10 -8-6 -4-2 0 2 4 6 8 10 12 14 16 18 LWT ( C) HT-HPF Version Brine Version * + Water + Glycol Water + Glycol Water -12-10 -8-6 -4-2 0 2 4 6 8 1012141618 LWT ( C)
114 Air cooled Chiller & Heat Pump Operating limit - Heating (to be confirmed following selection software issue) 240 270 290 320 360 SyScroll 240-360 Air HP Min Max Min Max Min Max Min Max Min Max Liquid outlet Water C +20 to +52 Warmed temperature Temperature spread K 3 to 7 liquid Maximum operating pressure bar 6 Ambient air Air entering temperature heating - / L / S C -10 to +20-10 to +20-10 to +20-10 to +20-10 to +20 HT C -12 to +20-12 to +20-12 to +20-12 to +20-12 to +20 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 720 810 870 960 1.080 Minimum capacity step % 31 33 30 27 23 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) 420 470 540 590 660 SyScroll 420-660 Air HP Min Max Min Max Min Max Min Max Min Max Liquid outlet Water C +20 to +52 Warmed temperature Temperature spread K 3 to 7 liquid Maximum operating pressure bar 6 Ambient air Air entering temperature heating - / L / S C 10 to +20-10 to +20-10 to +20-10 to +20-10 to +20 HT C -12 to +20-12 to +20-12 to +20-12 to +20-12 to +20 External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Recommended system chilled water volume 1 l 1.260 1.410 1.620 1.770 1.980 Minimum capacity step % 25 24 20 14 17 Power supply voltage 2 V 400 V / 3 Ø / 50 Hz (nominal) 1 Table shows minimum water / brine volume of system (about 3 lt/kw). 2 Voltage 400V +/- 10%. Heating mode (Cooling mode see page 43) OAT ( C) 25 20 15 10 5 0-5 -10 HT Version -15-20 15 20 25 30 35 40 45 50 55 60 LWT ( C)
Technical feature Air cooled Chiller & Heat Pump 115 Air Cooled Chiller & Heat Pump SyScroll 240-660 Air HP (STD-EC-HPF) 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 216,5 251,6 263,8 287,1 330,0 380,7 435,1 481,9 530,7 580,6 Input power 1 kw 85,5 100,5 105,2 113,9 131,3 151,7 169,1 189,9 207,3 228,3 EER 1 2,53 2,50 2,51 2,52 2,51 2,51 2,57 2,54 2,56 2,54 Energy efficiency class D D D D D D D D D D ESEER 3,55 3,43 3,52 3,66 3,66 3,79 3,80 3,66 3,74 3,82 EER * 2,56 2,53 2,54 2,55 2,54 2,54 2,60 2,56 2,59 2,57 ESEER * 3,63 3,50 3,60 3,74 3,74 3,88 3,89 3,74 3,81 3,90 EER ** 2,41 2,40 2,38 2,41 2,40 2,40 2,46 2,42 2,44 2,43 ESEER ** 3,21 3,16 3,19 3,32 3,31 3,43 3,45 3,35 3,41 3,58 Nominal heating capacity 2 kw 255,9 289,1 313,3 333,0 382,4 444,0 491,5 556,4 605,0 679,1 Input power 2 kw 92,7 106,8 117 117,4 136,2 159,7 170,5 191,2 209,2 231,1 COP 2 2,76 2,71 2,68 2,84 2,81 2,78 2,88 2,91 2,89 2,94 Energy efficiency class D D D C C D C C C C COP * 2,79 2,73 2,71 2,87 2,84 2,81 2,91 2,94 2,92 2,97 COP ** 2,63 2,60 2,56 2,71 2,68 2,66 2,75 2,78 2,76 2,81 Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 1 Plate Water flow cooling m 3 /h 37,4 43,5 45,6 49,5 57,0 65,8 75,1 83,2 91,6 100,3 Water pressure drop cooling kpa 42 55 61 29 38 50 38 46 44 53 Water flow heating 2 m 3 /h 43,8 49,4 53,5 57,1 65,5 76,0 84,2 95,3 103,6 116,2 Water pressure drop heating 2 kpa 56 71 83 38 49 65 48 60 56 70 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze heater W 130 130 130 130 130 130 130,0 130 130 130 Air cooled condenser Qty 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 900 900 900 900 900 900 900 900 900 900 Total airflow m 3 /h 107.500 107.500 129.000 129.000 150.500 172.000 193.500 215.000 236.500 258.000 Total input power kw 8,5 8,5 10,2 10,2 11,9 13,6 15,3 17,0 18,7 20,4 Total input power * kw 7,5 7,5 9,0 9,0 10,5 12,0 13,5 15,0 16,5 18,0 Total input power ** kw 13,0 13,0 15,6 15,6 18,2 20,8 23,4 26,0 28,6 31,2 External static pressure Pa 0 or 120 Pa ** Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.934 1.935 2.041 2.098 2.509 2.634 3.151 3.278 3.718 3.829 Operating kg 1.948 1.949 2.055 2.122 2.534 2.659 3.189 3.316 3.762 3.873 Additional weight HT/HPF versions kg 50 50 60 60 70 80 90 100 110 120 With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 3 db(a) 93 93 94 94 94 95 95 96 96 97 Sound pressure level 10 m 4 db(a) 61 61 62 62 62 63 63 64 63 64 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * Unità alta temperatura (HT) con ventilatori inverter. ** HPF Units with high static pressure fans.
116 Air cooled Chiller & Heat Pump Technical feature SyScroll 240-660 Air HP L 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 204,9 236,3 249,9 269,8 311,1 358,4 409,7 453,2 499,5 545,9 Input power 1 kw 88,6 105,2 109,0 118,7 137,0 158,0 176,3 197,8 216,1 237,8 EER 1 2,31 2,24 2,29 2,27 2,27 2,27 2,32 2,29 2,31 2,30 Energy efficiency class E F F F F F E F E F ESEER 3,50 3,29 3,51 3,56 3,66 3,80 3,77 3,60 3,82 3,79 Nominal heating capacity 2 kw 253,0 285,5 309,7 328,9 377,7 438,6 485,4 539,8 597,5 670,7 Input power 2 kw 90,1 104,1 113,6 114,1 132,3 155,1 165,7 188 202,7 224 COP 2 2,81 2,74 2,72 2,88 2,86 2,83 2,93 2,87 2,95 2,99 Energy efficiency class C D D C C C C C C C Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 1 Plate Water flow cooling m 3 /h 35,4 40,8 43,2 46,5 53,7 61,9 70,7 78,2 86,2 94,2 Water pressure drop cooling kpa 37 49 55 26 34 44 34 41 39 47 Water flow heating m 3 /h 43,3 48,8 52,9 56,4 64,7 75,1 83,2 92,4 102,4 114,8 Water pressure drop heating kpa 55 69 81 37 48 64 46 57 55 68 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze heater W 130 130 130 130 130 130 130 130 130 130 Air cooled condenser Qty 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 700 700 700 700 700 700 700 700 700 700 Total airflow m 3 /h 85.000 85.000 102.000 102.000 119.000 136.000 153.000 170.000 187.000 204.000 Total input power kw 6,0 6,0 7,2 7,2 8,4 9,6 10,8 12,0 13,2 14,4 Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.934 1.935 2.041 2.098 2.509 2.634 3.151 3.278 3.718 3.829 Operating kg 1.948 1.949 2.055 2.122 2.534 2.659 3.189 3.316 3.762 3.873 Additional weight With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 3 db(a) 88 88 89 89 90 91 91 91 92 92 Sound pressure level 10 m 4 db(a) 56 56 57 57 58 59 59 59 59 59 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 117 Air Cooled Chiller & Heat Pump SyScroll 240-660 Air HP S 240 270 290 320 360 420 470 540 590 660 Nominal cooling capacity 1 kw 186,8 212,3 228,4 243,4 281,5 324,0 370,5 409,0 451,5 492,5 Input power 1 kw 96,3 115,5 117,9 129,4 149,7 172,0 192,4 215,4 235,6 258,9 EER 1 1,94 1,84 1,94 1,88 1,88 1,88 1,93 1,90 1,92 1,90 Energy efficiency class G G G G G G G G G G ESEER 3,28 3,12 3,30 3,38 3,62 3,60 3,61 3,70 3,76 3,64 Nominal heating capacity 2 kw 249,0 280,7 304,8 323,3 371,4 431,3 477,3 540,4 587,5 659,5 Input power 2 kw 87,5 101 110 111,1 128,8 150,6 161,4 179,9 197,4 219,8 COP 2 2,85 2,78 2,77 2,91 2,88 2,86 2,96 3,00 2,98 3,00 Classe energetica C D D C C C C B C B Total capacity steps % 31-62- 100 33-67- 100 30-60- 100 27-64- 100 23-46- 69-100 25-50- 75-100 24-47- 65-82- 100 20-40- 60-800- 100 14-29- 43-62- 81-100 17-33- 50-67- 83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 2 2 Compressor Qty 3 3 3 3 4 4 5 5 6 6 Scroll Evaporator Qty 1 1 1 2 2 2 1 1 1 1 Plate Water flow cooling m 3 /h 32,2 36,7 39,5 42,0 48,6 55,9 63,9 70,6 77,9 85,0 Water pressure drop cooling kpa 31 40 46 21 28 36 28 34 32 38 Water flow heating m 3 /h 42,6 48,0 52,1 55,4 63,6 73,8 81,8 92,6 100,6 112,9 Water pressure drop heating kpa 53 67 79 36 47 62 45 57 53 66 Water volume l 14 14 14 24 24 24 32 32 39 39 Antifreeze heater W 130 130 130 130 130 130 130 130 130 130 Air cooled condenser Qty 5 5 6 6 7 8 9 10 11 12 Total coil face area per coil m 2 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 2,4 Fan Qty 5 5 6 6 7 8 9 10 11 12 Nominal speed rpm 550 550 550 550 550 550 550 550 550 550 Total airflow m 3 /h 67.500 67.500 81.000 81.000 94.500 108.000 121.500 135.000 148.500 162.000 Total input power kw 4,5 4,5 5,4 5,4 6,3 7,2 8,1 9,0 9,9 10,8 Water Connections (Evaporator) Male GAS Threaded Victaulic Inlet diameter inch 3 3 3 3 4 4 4 4 5 5 Outlet diameter inch 3 3 3 3 4 4 4 4 5 5 Water Connections (Desuperheater) Male GAS Threaded Inlet diameter/outlet diameter inch 1 /1 Weight Shipping kg 1.934 1.935 2.041 2.098 2.509 2.634 3.151 3.278 3.718 3.829 Operating kg 1.948 1.949 2.055 2.122 2.534 2.659 3.189 3.316 3.762 3.873 Additional weight With desuperheater kg 49 49 49 49 62 62 73 73 83 83 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 Acoustical data Sound power level 3 db(a) 85 86 87 87 88 88 89 89 90 90 Sound pressure level 10 m 4 db(a) 53 54 55 55 56 56 57 57 57 57 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
118 Air cooled Chiller & Heat Pump Air Cooled Heat Pump VLH 604-1204 149-300 kw Air cooled Scroll 170-337 kw Plate 410A Technical feature 7 sizes Cooling capacity from 149,4 to 299,9 kw Heating capacity from 169,8 to 337,4 kw 3 versions: STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions: BLN (Base Low Noise) LN (Low Noise) ELN (Extra Low Noise) Two refrigerant circuits Scroll compressors Microprocessor control Electronic expansion valve Inverter fans (Standard on HT) Polar version for extreme conditions (on request) Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater Fan speed control (-18 C) Hydrokit with 1 or 2 pumps with ot without buffer tank (500 lt) ( +1mt of lenght) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
Operating limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 119 Air Cooled Chiller & Heat Pump VLH 604-804 604 704 804 Min Max Min Max Min Max Water C from +6 to +15 Leaving water temperature Water + glycol C from 0 to +15 Water with Glycol (Brine version) C from -8 to +15 T K from 3 to 8 BLN C from -5 to +47 from -5 to +47 from 0 to +46 Cooling LN C from -5 to +45 from -5 to +45 from 0 to +44 Air temperature Cooling ELN C from -18 to +41 from -18 to +41 from -18 to +40 Cooling HT/HSE C from -18 to +49 from -18 to +49 from -18 to +48 Heating C from -10 (-4 LN/ELN) to + 20 High pressure fans Standard fans Pa 0 Invert fans HPF Pa <120 VLH 904-1204 904 1004 1104 1204 Min Max Min Max Min Max Min Max Water C from +6 to +15 Leaving water temperature Water + glycol C from 0 to +15 Water + Glycol (Brine version) C from -8 to +15 T K from 3 to 8 BLN C from 0 to +47 from 0 to +46 from 0 to +45 from 0 to +45 Cooling LN C from 0 to +45 from 0 to +44 from 0 to +42 from 0 to +42 Air temperature Cooling ELN C from -18 to +41 from -18 to +40 from -18 to +38 from -18 to +38 Cooling HT/HSE C from -18 to +49 from -18 to +48 from -18 a +47 from -18 to +47 Heating C from -10 (-4 LN/ELN) to + 20 External static pressure Standard fans Pa 0 Invert fans HPF Pa <120
120 Air cooled Chiller & Heat Pump Technical feature VLH STD/HPF 604-1204 BLN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 149,4 173,2 197,1 226,4 246,3 273,1 299,9 Power input 1 kw 56,4 66,1 72,2 82,6 86,7 99,7 114,0 EER 1 2,65 2,62 2,73 2,74 2,84 2,74 2,63 Energy efficiency class D D C C C C D ESEER 3,38 3,41 3,43 3,45 3,57 3,46 3,41 Heating capacity 2 kw 169,8 200,1 223,2 254,7 270,8 302,1 337,4 Power input 2 kw 58,0 67,4 70,4 79,6 87,6 100,0 112,5 COP 2 2,93 2,97 3,17 3,20 3,09 3,02 3,00 Energy efficiency class B B B A B B B Part load steps % 28-57-78-100 20-50-70-100 25-50-75-100 28-50-78-100 25-50-75-100 23-50-73-100 25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 25.817 29.928 33.987 38.992 42.449 47.110 51.686 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 900 900 900 900 900 900 900 Air flow m 3 /h 63.000 68.300 68.300 85.000 80.000 75.500 75.500 Power input kw 5,7 5,7 5,7 7,6 7,6 7,6 7,6 Static head pressure Pa from 0 to120 * Weight Shipping kg 1.473 1.663 1.806 1.955 2.100 2.190 2.200 Operating kg 1.485 1.675 1.820 1.980 2.125 2.215 2.225 Additional weights Versions HPF kg 30 30 30 40 40 40 40 With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 3 db(a) 91 91 91 92 92 93 93 Sound pressure level 4 db(a) 59 59 59 60 60 61 61 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * For version with High Pressure Fans (HPF).
Technical feature Air cooled Chiller & Heat Pump 121 Air Cooled Chiller & Heat Pump VLH STD 604-1204 LN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 145,4 168,2 191,2 220,4 237,3 261,2 285,1 Power input 1 kw 56,8 66,2 73,3 83,8 88,5 102,8 119,8 EER 1 2,56 2,54 2,61 2,63 2,68 2,54 2,38 Energy efficiency class D D D D D D E ESEER 3,60 3,58 3,64 3,59 3,70 3,63 3,49 Heating capacity 2 kw 165,7 195,0 217,1 247,7 261,8 288,9 322,2 Power input 2 kw 56,0 65,2 68,3 76,9 84,7 97,0 109,2 COP 2 2,96 2,99 3,18 3,22 3,09 2,98 2,95 Energy efficiency class C C B A B C C Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 25.094 29.102 32.955 38.046 40.901 45.081 49.226 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed gir/min 700 700 700 700 700 700 700 Air flow m 3 /h 47.300 52.200 52.200 63.700 58.800 54.900 54.900 Power input kw 3,6 3,6 3,6 4,8 4,8 4,8 4,8 Static head pressure Pa 0 Weight Shipping kg 1.473 1.663 1.806 1.955 2.100 2.190 2.200 Operating kg 1.485 1.675 1.820 1.980 2.125 2.215 2.225 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 3 db(a) 87 87 87 88 88 89 89 Sound pressure level 4 db(a) 55 55 55 56 56 57 57 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
122 Air cooled Chiller & Heat Pump Technical feature VLH STD 604-1204 eln 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 141,5 164,3 185,2 214,5 230,4 253,3 276,1 Power input 1 kw 58,0 69,0 76,2 86,1 90,7 106,9 124,9 EER 1 2,44 2,38 2,43 2,49 2,54 2,37 2,21 Energy efficiency class E E E E D E F ESEER 3,49 3,46 3,51 3,60 3,67 3,51 3,40 Heating capacity 2 kw 156,6 184,9 202,9 232,6 245,7 266,8 297,0 Power input 2 kw 55,0 64,9 67,0 75,8 83,9 95,0 108,0 COP 2 2,85 2,85 3,03 3,07 2,93 2,81 2,75 Energy efficiency class C C B B B C C COP HSE 2,95 2,95 3,13 3,19 3,04 2,90 2,83 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 24.458 28.311 31.940 36.945 39.732 43.705 47.592 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 550 550 550 550 550 550 550 Air flow m 3 /h 38.500 41.800 41.800 52.000 48.900 46.200 46.200 Power input kw 3 3 3 4 4 4 4 Static head pressure Pa 0 Weight Shipping kg 1.508 1.698 1.841 1.990 2.140 2.230 2.240 Operating kg 1.520 1.710 1.855 2.015 2.165 2.255 2.265 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 3 db(a) 83 83 83 84 84 85 85 Sound pressure level 4 db(a) 51 51 51 52 52 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 123 Air Cooled Chiller & Heat Pump VLH 604-1204 ht 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 151,7 175,6 199,7 229,5 250,1 276,5 305,6 Power input 3 kw 49,2 58,4 64,4 73,2 76,8 89,9 102,8 EER 2,69 2,69 2,80 2,77 2,88 2,77 2,71 Energy efficiency class D D D D D D E Heating capacity 2 kw 170,5 200,7 224,0 256,6 273,7 305,5 341,5 Power input 3 kw 51,3 60,6 63,5 71,4 79,3 91,4 103,5 COP 2,91 2,97 3,18 3,17 3,07 3,01 3,01 Energy efficiency class C C B A B C C Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 26.092 30.203 34.348 39.474 43.017 47.558 52.563 Connection type Male GAS threaded Inlet/outlet diameter inch 2½ 2½ 2½ 3 3 3 3 Condenser Qty 2 Total coil face area per coil mm 2 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 1.110 1.110 1.110 1.110 1.110 1.110 1.110 Air flow m 3 /h 71.800 76.200 76.200 95.800 91.200 87.600 87.600 Power input kw 7,2 6,9 6,9 9,6 9,9 10 10 Static head pressure Pa 0 Weight Shipping kg 1.503 1.693 1.836 1.995 2.140 2.230 2.240 Operating kg 1.515 1.705 1.850 2.020 2.165 2.255 2.265 Additional weights With desuperheater kg 20 20 30 30 30 30 30 With one pump kg 50 85 85 90 90 95 95 With two pumps kg 140 200 200 205 205 215 215 With copper/copper coils kg 380 520 520 520 700 880 880 Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Acoustical data Sound power level 4 db(a) 99 99 99 100 100 100 100 Sound pressure level 5 db(a) 67 67 67 68 68 68 68 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Input power (only compressors). 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
124 Air cooled Chiller & Heat Pump Air Cooled Heat Pump AQWH 1404-2406 359-602 kw Air cooled Scroll 420-702 kw Plate 410A Technical feature 5 sizes Cooling capacity from 358,8 to 601,9 kw Heating capacity 420,0 to702,0 kw 4 versions: STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions: BLN (Basic Low Noise) LN (Low Noise) ELN (Extra Low Noise) Two refrigerant circuits Scroll compressors Electronic expansion valve Inverter fans (Standard HSE and HT) Polar version for extreme conditions (on request) Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard ELN) Desuperheater Fan speed control (-18 C) Hydrokit with 1 or 2 pumps with or without buffer tank (750 or 1.000 liters size 2106-2406) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
Opearting limit (to be confirmed following selection software issue) Air cooled Chiller & Heat Pump 125 Air Cooled Chiller & Heat Pump AQWH 1404-2406 1404 1604 1806 2106 2406 Min Max Min Max Min Max Min Max Min Max Acqua C from +6 to +15 Leaving water temperature Water + glicol C from -8 to +15 T К from 3 to 8 Leaving water temperature (heating) C from 30 to 50 BLN C from -5 to +44 from 0 to +44 from 0 to +44 from 0 to +44 from 0 to +44 LN C from -5 to +42 from 0 to +42 from 0 to +42 from 0 to +42 from 0 to +42 Air temperature ELN C from -18 to +40 from -18 to +40 from -18 to +40 from -18 to +40 from -18 to +40 HT C from -18 to +45 from -18 to +45 from -18 to +45 from -18 to +45 from -18 to +45 Heating C from -10 (-4 LN/ELN) to +20 Heating (Polar Version) C from -15 to +20 External static pressure Standard fans Pa 0 Inverter fans SIF Pa < 120
126 Air cooled Chiller & Heat Pump Technical feature AQWH STD/HSE/HPF 1404-2406 BLN 1404 1604 1806 2106 2406 Cooling capacity 1 kw 358,8 400,6 470,4 534,8 601,9 Power input 1 kw 134,9 150,0 175,5 199,6 224,6 EER 1 2,66 2,67 2,68 2,68 2,68 Energy Efficiency class D D D D D ESEER 3,47 3,54 3,55 3,59 3,59 EER HSE 1 2,69 2,70 2,71 2,71 2,71 Energy Efficiency class D C C C C ESEER HSE 1 3,57 3,69 3,73 3,79 3.73 Heating capacity 2 kw 420,0 470,1 548,3 627,2 702,0 Power input 2 kw 132,5 146,5 172,4 194,2 220,8 Energy Efficiency class B A B A B COP 2 3,17 3,21 3,18 3,23 3,18 Energy Efficiency class A A A A A COP HSE 2 3,21 3,24 3,22 3,26 3,22 Part load steps % 21-50- 71-100 25-50- 75-100 17-33-50-67-83-100 15-29-43-62-81-100 17-33-50-67-83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 4 6 6 6 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 61.950 69.092 81.210 92.371 103.532 Connection type Victaulic Inlet/outlet diameter inch 4 4 4 4 4 Condenser Qty 4 4 4 4 4 Total coil face area per coil mm 2 4,4 4,4 5,6 6,7 6,7 Fan Qty 8 8 10 10 12 Speed rpm/min 880 880 880 880 880 Air flow m 3 /h 181.000 181.000 200.000 214.500 242.000 Power input kw 14,4 14,4 18,0 18,0 21,6 Power input HSE kw 13,0 13,0 16,3 16,3 19,6 Static head pressure Pa from 0 to 120 ** Weight Shipping kg 2.896 3.018 3.967 4.083 4.465 Operating kg 2.931 3.056 4.007 4.123 4.507 Dimensions Length mm 4.000 4.000 5.000 6.000 6.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 3 db(a) 97 97 98 98 99 Sound pressure level 4 db(a) 65 65 66 66 67 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. ** HPF Units with high static pressure fans.
Technical feature Air cooled Chiller & Heat Pump 127 Air Cooled Chiller & Heat Pump AQWH STD/HSE 1404-2406 LN 1404 1604 1806 2106 2406 Cooling capacity 1 kw 346,8 386,7 455,5 518,0 582,0 Power input 1 kw 134,9 149,9 176,6 200,0 223,0 EER 1 2,57 2,58 2,58 2,59 2,61 Energy Efficiency class D D D D D ESEER 3,57 3,63 3,68 3,70 3,73 EER HSE 1 2,63 2,63 2,64 2,64 2,56 Energy Efficiency class D D D D D ESEER HSE 1 3,74 3,85 3,94 3,95 3,84 Heating capacity 2 kw 397,7 445,8 519,0 593,8 665,4 Power input 2 kw 126,3 141,5 165,8 187,9 212,6 COP 2 3,15 3,15 3,13 3,16 3,13 Energy Efficiency class B B B B B COP HSE 2 3,22 3,22 3,20 3,23 3,22 Energy Efficiency class A A A A A Part load steps % 21-50- 71-100 25-50- 75-100 17-33-50-67-83-100 15-29-43-62-81-100 17-33-50-67-83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 4 6 6 6 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 59.821 66.787 78.655 89.474 100.104 Connection type Victaulic Inlet/outlet diameter inch 4 4 4 4 4 Condenser Qty 4 Total coil face area per coil mm 2 4,4 4,4 5,6 6,7 6,7 Fan Qty 8 8 10 10 12 Speed rpm/min 700 700 700 700 700 Air flow m 3 /h 142.000 142.000 153.000 165.000 183.000 Power input kw 9,6 9,6 12,0 12,0 14,4 Power input HSE kw 6,6 6,6 8,2 8,2 9,8 Static head pressure Pa 0 Weight Shipping kg 2.896 3.018 3.967 4.083 4.465 Operating kg 2.931 3.056 4.007 4.123 4.507 Dimensions Length mm 4.000 4.000 5.000 6.000 6.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 4 db(a) 91 91 92 92 93 Sound pressure level 5 db(a) 59 59 60 60 61 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
128 Air cooled Chiller & Heat Pump Technical feature AQWH STD/HSE 1404-2406 ELN 1404 1604 1806 2106 2406 Cooling capacity 1 kw 328,9 366,9 432,7 490,2 551,1 Power input 1 kw 143,0 158,8 187,3 211,3 237,5 EER 1 2,30 2,31 2,31 2,32 2,32 Energy Efficiency class E E E E E ESEER 3,28 3,38 3,48 3,49 3,49 EER HSE 1 2,42 2,42 2,42 2,42 2,42 Energy Efficiency class E E E E E ESEER HSE 1 3,51 3,61 3,69 3,67 3,67 Heating capacity 2 kw 381,6 427,6 498,4 570,5 639,0 Power input 2 kw 126,36 140,2 165,58 187,66 200,3 COP 2 3,02 3,05 3,01 3,04 3,19 Energy Efficiency class B B B B B COP HSE 2 3,20 3,21 3,17 3,19 3,03 Energy Efficiency class A A B B B Part load steps % 21-50- 71-100 25-50- 75-100 17-33-50-67-83-100 15-29-43-62-81-100 17-33-50-67-83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 4 6 6 6 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 56.794 63.244 74.579 84.675 94.789 Connection type Victaulic Inlet/outlet diameter inch 4 4 4 4 4 Condenser Qty 4 Total coil face area per coil mm 2 4,4 4,4 5,6 6,7 6,7 Fan Qty 8 8 10 10 12 Speed rpm/min 550 550 550 550 550 Air flow m 3 /h 112.000 112.000 120.000 130.000 144.000 Power input kw 9,6 9,6 12,0 12,0 14,4 Power input HSE kw 2,6 2,6 3,2 3,2 3,8 Static head pressure Pa 0 Weight Shipping kg 2.896 3.018 3.967 4.083 4.465 Operating kg 2.931 3.056 4.007 4.123 4.507 Dimensions Length mm 4.000 4.000 5.000 6.000 6.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 3 db(a) 88 88 89 89 90 Sound pressure level 4 db(a) 56 56 57 57 58 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical feature Air cooled Chiller & Heat Pump 129 Air Cooled Chiller & Heat Pump AQWH 1404-2406 HT 1404 1604 1806 2106 2406 Cooling capacity 1 kw 363,8 405,7 477,0 542,3 608,0 Power input 3 kw 117,8 132,7 154,4 176,7 199,0 EER 2,73 2,64 2,72 2,64 2,64 Heating capacity 2 kw 422,0 473,0 551,0 630,0 709,0 Power input 3 kw 114,8 128,7 150,3 171,7 193,0 COP 3,11 3,16 3,13 3,19 3,16 Part load steps % 21-50- 71-100 25-50- 75-100 17-33-50-67-83-100 15-29-43-62-81-100 17-33-50-67-83-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 4 6 6 6 Scroll Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/h 62.573 69.780 82.044 93.275 104576 Connection type Victaulic Inlet/outlet diameter inch 4 4 4 4 4 Condenser Qty 4 Total coil face area per coil mm 2 4,4 4,4 5,6 6,7 6,7 Fan Qty 8 8 10 10 12 Speed rpm/min 1.100 1.100 1.100 1.100 1.100 Air flow m 3 /h 220.000 220.000 244.000 278.000 295.000 Power input kw 20,8 20,8 26,0 26,0 31,2 Static head pressure HSE Pa 0 Weight Shipping kg 2.896 3.018 3.967 4.083 4.465 Operating kg 2.931 3.056 4.007 4.123 4.507 Dimensions Length mm 4.000 4.000 5.000 6.000 6.000 Width mm 2.200 2.200 2.200 2.200 2.200 Height mm 2.550 2.550 2.550 2.550 2.550 Acoustical data Sound power level 4 db(a) 103 103 104 104 105 Sound pressure level 5 db(a) 71 71 72 72 73 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard.. 4 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 5 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water Cooled Chiller, Heat Pump and Condensing unit Water Cooled Chiller & Heat Pump WQL/WQH/WQRC 20-190 21-193 kw 24-212 kw 410A Scroll Plate WQL/WQH/WQRC 524-1204 154-379 kw 170-419 kw 410A Scroll Plate SyScrew 440-1550 Water EVO CO/HP/RC 444-1.567 kw 134a Screw Shell & Tube
132 Water cooled Chiller & Heat Pump Selection guide Water Cooled Chiller WQL 20-190 Product Range Cooling Capacity EER Flow rate Acoustic Power WQL 524-1204 WQL 20 21,2 kw 4,58 1,02 l/s 65 db(a) WQL 25 26,2 kw 4,54 1,26 l/s 67 db(a) WQL 30 31,1 kw 4,46 1,5 l/s 67 db(a) WQL 35 34,8 kw 4,53 1,68 l/s 68 db(a) WQL 40 39,2 kw 4,48 1,89 l/s 68 db(a) WQL 45 46,6 kw 4,57 2,24 l/s 70 db(a) WQL 50 50,9 kw 4,29 2,44 l/s 70 db(a) WQL 60 61,1 kw 4,48 2,93 l/s 70 db(a) WQL 75 77,3 kw 4,48 3,71 l/s 72 db(a) WQL 90 91,1 kw 4,38 4,37 l/s 73 db(a) WQL 120 118,4 kw 4,46 5,68 l/s 78 db(a) WQL 150 147,1 kw 4,46 7,05 l/s 81 db(a) WQL 170 170 kw 4,5 8,15 l/s 81 db(a) WQL 190 192,7 kw 4,51 9,24 l/s 81 db(a) WQL 524 154,3 kw 4,51 7,4 l/s 81 db(a) WQL 604 181,8 kw 4,37 8,71 l/s 82 db(a) WQL 704 208,9 kw 4,4 10,01 l/s 85 db(a) WQL 804 232,6 kw 4,36 11,2 l/s 87 db(a) WQL 904 265,8 kw 4,48 12,7 l/s 89 db(a) WQL 1004 295,6 kw 4,51 14,1 l/s 90 db(a) WQL 1104 338 kw 4,51 16,2 l/s 90 db(a) WQL 1204 379,2 kw 4,55 18,2 l/s 90 db(a) Size (LxHxP) mm 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 136,5 kw
Water cooled Chiller & Heat Pump 133 SyScrew 440-1550Water EVO CO Product Range Capacity EER Flow rate Acoustic Power SyScrew 440 Water EVO CO SyScrew 490 Water EVO CO SyScrew 570 Water EVO CO SyScrew 630 Water EVO CO SyScrew 700 Water EVO CO SyScrew 770 Water EVO CO SyScrew 860 Water EVO CO SyScrew 920 Water EVO CO SyScrew 990 Water EVO CO SyScrew 1070 Water EVO CO SyScrew 1130 Water EVO CO SyScrew 1220 Water EVO CO SyScrew 1280 Water EVO CO SyScrew 1400 Water EVO CO SyScrew 1550 Water EVO CO 444,3 kw 5,06 21,3 l/s 95 db(a) 494,4 kw 5,05 23,6 l/s 95 db(a) 570,4 kw 5,07 27,3 l/s 95 db(a) 636,2 kw 5,07 30,5 l/s 95 db(a) 708,5 kw 5,05 33,9 l/s 95 db(a) 787,1 kw 5,06 37,7 l/s 95 db(a) 875,5 kw 5,06 41,94 l/s 98 db(a) 936 kw 5,05 44,86 l/s 98 db(a) 998,6 kw 5,05 47,86 l/s 98 db(a) 1.071,4 kw 5,06 51,36 l/s 98 db(a) 1.132,9 kw 5,06 54,33 l/s 98 db(a) 1.224,1 kw 5,08 58,61 l/s 98 db(a) 1.285,2 kw 5,06 61,56 l/s 98 db(a) 1.567 kw 1.428,5 kw 5,06 68,53 l/s 98 db(a) 5,06 75,22 l/s 98 db(a) Size (LxHxP) mm 3.620 x 1.750 x 1.350 3.620 x 1.750 x 1.350 4.210 x 1.750 x 1.350 4.210 x 1.750 x 1.350 4.180 x 1.750 x 1.350 4.180 x 1.750 x 1.350 4.400 x 1.710 x 1.520 4.400 x 1.710 x 1.520 4.600 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 5350 x 1.710 x 1.520 5350 x 1.710 x 1.520 Water Cooled Chiller & Heat Pump
134 Water cooled Chiller & Heat Pump Selection guide Water Heat Pump WQH 20-190 Product Range Heating Capacity COP Flow rate Acoustic Power WQH 524-1204 WQH 20 23,7 kw 3,88 1,13 l/s 65 db(a) WQH 25 28,9 kw 3,85 1,38 l/s 67 db(a) WQH 30 33,6 kw 3,73 1,61 l/s 67 db(a) WQH 35 38,5 kw 3,79 1,84 l/s 68 db(a) WQH 40 42,9 kw 3,77 2,05 l/s 68 db(a) WQH 45 51,2 kw 3,85 2,45 l/s 70 db(a) WQH 50 57,7 kw 3,83 2,73 l/s 70 db(a) WQH 60 68,2 kw 3,81 3,23 l/s 70 db(a) WQH 75 86,3 kw 3,92 4,09 l/s 72 db(a) WQH 90 102,2 kw 3,89 4,84 l/s 73 db(a) WQH 120 132 kw 3,92 6,24 l/s 78 db(a) WQH 150 164,2 kw 3,95 7,78 l/s 81 db(a) WQH 170 190,1 kw 3,93 9 l/s 81 db(a) WQH 190 212,3 kw 3,93 10,05 l/s 81 db(a) WQH 524 170,2 kw 3,85 8,1 l/s 81 db(a) WQH 604 201,1 kw 3,75 9,57 l/s 82 db(a) WQH 704 231,8 kw 3,85 11 l/s 85 db(a) WQH 804 256,5 kw 3,75 12,2 l/s 87 db(a) WQH 904 295,6 kw 3,82 14,1 l/s 89 db(a) WQH 1004 331 kw 3,94 15,8 l/s 90 db(a) WQH 1104 376,6 kw 3,94 18 l/s 90 db(a) WQH 1204 418,5 kw 3,94 20 l/s 90 db(a) Size (LxHxP) mm 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 821 x 1.350 x 455 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 1.210 x 1.500 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850 2.250 x 1.845 x 850
Water cooled Chiller & Heat Pump 135 SyScrew 440-1550Water EVO HP Product Range Capacity COP Flow rate Acoustic Power SyScrew 440 Water EVO HP SyScrew 490 Water EVO HP SyScrew 570 Water EVO HP SyScrew 630 Water EVO HP SyScrew 700 Water EVO HP SyScrew 770 Water EVO HP SyScrew 860 Water EVO HP SyScrew 920 Water EVO HP SyScrew 990 Water EVO HP SyScrew 1070 Water EVO HP SyScrew 1130 Water EVO HP SyScrew 1220 Water EVO HP SyScrew 1280 Water EVO HP SyScrew 1400 Water EVO HP SyScrew 1550 Water EVO HP 487,7 kw 4,68 27,08 l/s 95 db(a) 549,1 kw 4,75 30,64 l/s 95 db(a) 634,6 kw 4,65 35,22 l/s 95 db(a) 707,9 kw 4,61 39,19 l/s 95 db(a) 791,9 kw 4,58 43,72 l/s 95 db(a) 862,1 kw 4,65 47,81 l/s 95 db(a) 960,2 kw 4,7 53,39 l/s 98 db(a) 1.033,2 kw 4,71 57,50 l/s 98 db(a) 1.109,2 kw 4,73 61,78 l/s 98 db(a) 1.189,3 kw 4,67 66,03 l/s 98 db(a) 1.257 kw 4,63 69,61 l/s 98 db(a) 1.359,9 kw 4,68 75,50 l/s 98 db(a) 1.593,1 kw 1.426,9 kw 4,68 79,22 l/s 98 db(a) 1.714,6 kw 4,53 87,72 l/s 98 db(a) 4,60 94,83 l/s 98 db(a) Size (LxHxP) mm 3.620 x 1.750 x 1.350 3.620 x 1.750 x 1.350 4.210 x 1.750 x 1.350 4.210 x 1.750 x 1.350 4.180 x 1.750 x 1.350 4.180 x 1.750 x 1.350 4.400 x 1.710 x 1.520 4.400 x 1.710 x 1.520 4.600 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 4.650 x 1.710 x 1.520 5350 x 1.710 x 1.520 5350 x 1.710 x 1.520 Water Cooled Chiller & Heat Pump
136 Water cooled Chiller & Heat Pump Water Cooled Chiller, Heat Pump and Condensing WQL/WQH/WQRC 20-190 21-193 kw Water cooled Scroll 24-212 kw Plate 410A Technical features 14 sizes Cooling capacity from 21,2 to 192,7 kw Heating capacity from 23,7 to 212,3 kw 3 versions: WQL (Cooling only) WQH (Heat pump) WQRC (Condenserless) 2 acoustic versions: BLN (Basic Low Noise) ELN (Extra Low Noise) 2 frames: F1 (size from 20 to 45) F2 (size from 50 to 190) One refrigerant circuit Scroll compressors Accessories and options BMS interface Compressors acoustic box (standard on ELN) Compressors jackets Desuperheater available for frame 2 Differential pressure switch (standard) Electronic expansion valve (standard WQRC 170-190) Hydrokit with 1 or 2 pumps for evaporator and condenser Mechanical gauges kit Power factor corrector capacitors Sequence phases control (standard) Sofstart Water filter Water flow switch
Water cooled Chiller & Heat Pump 137 Operating limit (to be confirmed following selection software issue) WQL-WQH 20-190 Leaving water temperature (cooling) Water C from +5 to +18 Water + glycol C -8 / +5 (with glycol + electronic expansion valve); +5/+18 (standard) Water Cooled Chiller & Heat Pump T K from 3 to 8 Leaving water temperature (heating) Water C from +25 to +55 T C from 3 to 15 Note: maximum % glycol (ethylenic or propilenic): 40%. WQRC 20-190 Water C from +5 to +18 Leaving water temperature (cooling) Water + glycol C -8 / +5 (with glycol + electronic expansion valve); +5/+18 (standard) T K from 3 to 8 Note: maximum % glycol (ethylenic or propilenic): 40%.
138 Water cooled Chiller & Heat Pump Technical feature WQL 20-45 20 25 30 35 40 45 Cooling capacity 1 kw 21,2 26,2 31,1 34,8 39,2 46,6 Input power 1 kw 4,63 5,77 6,97 7,68 8,75 10,2 EER 1 4,58 4,54 4,46 4,53 4,48 4,57 Energy Efficiency class C C C C C C ESEER 5,16 5,09 4,93 4,95 4,81 5,08 Part load steps % 0-100 0-100 0-100 0-100 0-100 0-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 1 Scroll Crankcase heater W 70 90 90 90 90 90 Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/s 1,02 1,26 1,5 1,68 1,89 2,24 Water pressure drop kpa 17,7 26,2 35,6 43,9 40,5 39,7 Connection type Victaulic Inlet/outlet diameter inch 1½ 1½ 1½ 1½ 1½ 1½ Evaporator pump Power input kw 1,06 1,06 1,06 1,32 1,32 1,32 Available static pressure kpa 251 222 189 198 187 159 Condenser Qty 1 Plate exchanger AISI 316 Water flow l/s 1,23 1,52 1,80 2,02 2,28 2,70 Water pressure drop kpa 14,5 21,4 57,4 35,8 44,8 26,5 Connection type Victaulic Inlet/outlet diameter inch 1½ 1½ 1½ 1½ 1½ 1½ Condenser pump Power input kw 1,06 1,06 1,32 1,32 1,32 1,32 Available static pressure kpa 236 199 161 183 155 132 Weight Shipping kg 156 176 174 179 185 203 Operating kg 162 182 179 185 191 214 Dimensions Length mm 821 821 821 821 821 821 Width mm 455 455 455 455 455 455 Height mm 1.350 1.350 1.350 1.350 1.350 1.350 Acoustical data Sound power level 2 / 3* db(a) 65/62 67/64 67/64 68/65 68/66 70/67 Sound pressure level at 10 m 2 / 3** db(a) 34/31 36/33 36/33 37/34 38/35 39/36 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 BLN version. 3 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water cooled Chiller & Heat Pump 139 Technical feature WQH 20-45 20 25 30 35 40 45 Cooling capacity 1 kw 20,8 26,0 30,1 34,0 38,2 45,5 Power input 1 kw 4,67 5,82 7,03 7,82 8,80 10,4 EER 1 4,45 4,47 4,28 4,35 4,34 4,39 Energy Efficiency class C C C C C C ESEER 4,95 5,03 4,80 4,86 4,67 4,86 Heating capacity 2 23,7 28,9 33,6 38,5 42,9 51,2 Power input 2 6,11 7,51 9,01 10,2 11,4 13,3 COP 2 3,88 3,85 3,73 3,79 3,77 3,85 Energy Efficiency class C C D D D C Part load steps % 0-100 0-100 0-100 0-100 0-100 0-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 1 Scroll Crankcase heater W 70 90 90 90 90 90 Internal heat exchanger Qty 1 Plate exchanger AISI 316 Water flow rate - cooling l/s 1,00 1,25 1,45 1,63 1,83 2,19 Pressure drop - cooling kpa 17,0 25,6 33,4 41,7 38,3 38,2 Water flow rate - heating l/s 1,13 1,38 1,61 1,84 2,05 2,45 Pressure drop - heating kpa 21,8 31,4 41,1 52,8 47,8 47,7 Connection type Victaulic Inlet/outlet diameter inch 1½ 1½ 1½ 1½ 1½ 1½ Internal heat exchanger pump Power input kw 1,06 1,06 1,06 1,32 1,32 1,32 Available static pressure - cooling kpa 253 224 196 203 193 165 Available static pressure - heating kpa 239 208 172 181 171 139 External heat exchanger Qty 1 Plate exchanger AISI 316 Water flow l/s 1,21 1,51 1,76 1,98 2,23 2,66 Water pressure drop kpa 13,6 20,5 54,8 33,8 42,2 25,5 Connection type Victaulic Inlet/outlet diameter inch 1½ 1½ 1½ 1½ 1½ 1½ Internal heat exchanger pump Power input kw 1,06 1,06 1,32 1,32 1,32 1,32 Available static pressure - heating kpa 238 201 167 187 161 137 Weight Shipping kg 159 181 179 184 190 208 Operating kg 165 187 184 190 195 219 Dimensions Length mm 821 821 821 821 821 821 Width mm 455 455 455 455 455 455 Height mm 1.350 1.350 1.350 1.350 1.350 1.350 Acoustical data Sound power level 3 / 4* db(a) 65/62 67/64 67/64 68/65 68/66 70/67 Sound pressure level at 10 m 3 / 4** db(a) 34/31 36/33 36/33 37/34 38/35 39/36 Water Cooled Chiller & Heat Pump 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 BLN version. 4 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
140 Water cooled Chiller & Heat Pump Technical feature WQRC 20-45 20 25 30 35 40 45 Cooling capacity 1 kw 20,9 26,0 31,3 34,8 39,3 46,2 Power input 2 kw 4,54 5,61 6,37 7,24 8,15 9,89 Part load steps % 0-100 0-100 0-100 0-100 0-100 0-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 Compressor Qty 1 Scroll Crankcase heater W 70 90 90 90 90 90 Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/s 1,00 1,24 1,50 1,66 1,88 2,21 Water pressure drop kpa 17,1 25,4 35,6 43,7 34,3 38,9 Connection type Victaulic Inlet/outlet diameter inch 1½ 1½ 1½ 1½ 1½ 1½ Evaporator pump Qty 1 1 1 1 1 1 Power input kw 1,06 1,06 1,06 1,32 1,32 1,32 Available static pressure kpa 253 225 188 200 188 163 Remore condenser refrigerant connections Connection type To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅝ ⅝ ⅝ Outlet diameter inch ⅝ ⅞ ⅞ ⅞ ⅞ ⅞ Weight Shipping kg 142 161 163 163 169 168 Operating kg 144 164 166 166 172 172 Dimensions Length mm 821 821 821 821 821 821 Width mm 455 455 455 455 455 455 Height mm 1.350 1.350 1.350 1.350 1.350 1.350 Acoustical data Sound power level 3 / 4* db(a) 65/62 67/64 67/64 68/65 68/66 70/67 Sound pressure level at 10 m 3 / 4** db(a) 34/31 36/33 36/33 37/34 38/35 39/36 1 Data refered to evaporator water temperature 12/7 C and condenser water temperature 40 C. 2 Input power (only compressors). 3 BLN version. 4 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water cooled Chiller & Heat Pump 141 Technical feature WQL 50-190 50 60 75 90 120 150 170 190 Cooling capacity 1 kw 50,9 61,1 77,3 91,1 118,4 147,1 170,0 192,7 Power input 1 kw 11,9 13,6 17,3 20,8 26,6 33,0 37,8 42,7 EER 1 4,29 4,48 4,48 4,38 4,46 4,46 4,50 4,51 Energy Efficiency class C C C C C C C C ESEER 5,68 5,95 5,53 5,92 5,58 5,38 5,38 5,41 Part load steps % 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 1 1 Compressor Qty 2 Scroll Crankcase heater W 90+90 90+90 90+90 90+90 120+120 150+150 150+150 150+150 Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/s 2,44 2,93 3,71 4,37 5,68 7,05 8,15 9,24 Water pressure drop kpa 25,1 20,2 21,4 20,7 21,2 22,6 24,4 25,0 Connection type Victaulic Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ Evaporator pump Power input (SP version) kw 1,10 1,10 1,99 1,99 2,45 2,45 3,00 3,00 Available static pressure (SP version) kpa 127 124 154 145 157 121 180 152 Power input (HP version) kw 2,20 2,20 3,26 3,26 3,00 3,00 4,00 4,00 Available static pressure (HP version) kpa 244 241 246 235 241 214 248 221 Condenser Qty 1 Plate exchanger AISI 316 Water flow l/s 2,98 3,55 4,50 5,33 6,90 8,57 9,89 11,21 Water pressure drop kpa 35,0 27,0 29,0 28,0 29,0 32,0 34,0 35,0 Connection type Victaulic Inlet/outlet diameter pollici 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ Condenser pump Power input (SP version) kw 1,10 1,10 1,99 1,99 2,45 3,00 3,00 4,00 Available static pressure (SP version) kpa 107 100 134 116 114 165 115 145 Power input (HP version) kw 2,20 2,20 3,26 3,26 3,00 4,00 5,50 5,50 Available static pressure (HP version) kpa 226 221 224 211 206 234 247 200 Desuperheater Qty 1 Plate exchanger AISI 316 Heat recovery kw 11,0 14,2 18,1 21,0 25,2 34,1 39,1 41,0 Water flow l/s 0,53 0,68 0,86 1,00 1,20 1,63 1,87 1,96 Water pressure drop kpa 8,3 4,5 5,1 5,7 5,0 8,7 10,3 7,5 Weight Shipping kg 433 481 528 577 818 942 1.013 1.113 Operating kg 440 491 540 591 837 966 1.041 1.145 Dimensions Length mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210 Width mm 850 850 850 850 850 850 850 850 Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 Acoustical data Sound power level 2 / 3* db(a) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79 Sound pressure level at 10 m 2 / 3** db(a) 39/37 39/37 40/39 42/40 47/45 50/48 50/48 50/48 Water Cooled Chiller & Heat Pump 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 BLN version. 3 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. SP version: low pressure pump. HP version: high pressure pump.
142 Water cooled Chiller & Heat Pump Technical feature WQH 50-190 50 60 75 90 120 150 170 190 Cooling capacity 1 kw 49,9 58,9 76,1 88,6 114,9 144,3 165,7 185,4 Power input 1 kw 12,0 13,9 17,5 21,1 27,0 33,3 38,2 43,3 EER 1 4,15 4,24 4,36 4,20 4,26 4,34 4,34 4,28 Energy Efficiency class D D C D C C C C ESEER 5,48 5,62 5,43 5,60 5,25 5,22 5,31 5,09 Heating capacity 2 kw 57,7 68,2 86,3 102,2 132,0 164,2 190,1 212,3 Power input 2 kw 15,1 17,9 22,0 26,3 33,7 41,6 48,4 54,0 COP 2 3,83 3,81 3,92 3,89 3,92 3,95 3,93 3,93 Energy Efficiency class D D C C C C C C Part load steps % 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 1 1 Compressor Qty 2 Scroll Crankcase heater W 90+90 90+90 90+90 90+90 120+120 150+150 150+150 150+150 Internal heat exchanger Qty 1 Plate exchanger AISI 316 Water flow rate - cooling l/s 2,40 2,83 3,65 4,25 5,51 6,92 7,95 8,89 Pressure drop - cooling kpa 24,1 18,8 20,7 19,7 20,0 21,8 23,2 23,3 Water flow rate - heating l/s 2,73 3,23 4,09 4,84 6,24 7,78 9,00 10,05 Pressure drop - heating kpa 31,3 24,4 26,0 25,5 25,7 27,6 29,8 29,7 Connection type Victaulic Inlet/outlet diameter pollici 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ Internal heat pump Operation Cooling Available static pressure (SP version) kpa 129 127 156 148 162 126 187 164 Available static pressure (HP version) kpa 245 244 247 238 245 218 254 233 Operating Heating Available static pressure (SP version) kpa 115 113 144 132 139 93 150 121 Available static pressure (HP version) kpa 233 231 236 223 225 192 219 192 External heat exchanger Qty 1 Plate exchanger AISI 316 Water flow l/s 2,94 3,46 4,45 5,22 6,75 8,45 9,7 10,9 Water pressure drop kpa 37,3 28,7 31,2 29,2 29,5 32,1 34,8 34,1 Connection type Victaulic Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ Internal heat pump Available static pressure (SP version) kpa 108 104 135 120 120 170 123 158 Available static pressure (HP version) kpa 227 224 226 214 210 238 255 215 Weight Shipping kg 441 489 539 588 831 959 1.031 1.130 Operating kg 448 499 551 602 850 983 1.058 1.162 Dimensions Length mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210 Width mm 850 850 850 850 850 850 850 850 Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 Acoustical data Sound power level 3 / 4* db(a) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79 Sound pressure level at 10 m 3 / 4** db(a) 39/37 39/37 40/39 42/40 47/45 50/48 50/48 50/48 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 BLN version. 4 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. SP version: low pressure pump. HP version: high pressure pump.
Water cooled Chiller & Heat Pump 143 Technical feature WQRC 50-190 50 60 75 90 120 150 170 190 Cooling capacity 1 kw 51,2 61,7 77,8 91,4 118,7 147,6 169,4 193,2 Power input 1 kw 11,2 12,9 16,5 20,0 25,7 31,8 36,9 41,4 Part load steps % 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 1 1 1 1 1 1 1 1 Compressor Qty 2 Scroll Crankcase heater W 90+90 90+90 90+90 90+90 120+120 150+150 150+150 150+150 Evaporator Qty 1 Plate exchanger AISI 316 Water flow l/s 2,45 2,95 3,72 4,37 5,67 7,05 8,09 9,23 Water pressure drop kpa 25,2 20,5 21,5 20,7 21,2 22,6 24,1 24,9 Connection type Victaulic Inlet/outlet diameter inch 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ Evaporator pump Qty 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Power Input (SP version) kw 1,10 1,10 1,99 1,99 2,45 2,45 3,00 3,00 Available static pressure (SP version) kpa 127 123 154 145 157 121 182 152 Power Input (HP version) kw 2,20 2,20 3,26 3,26 3,00 3,00 4,00 4,00 Available static pressure (HP version) kpa 244 240 245 235 241 214 250 221 Remote condenser refrigerant connections Connection type To be brazed Inlet diameter inch ⅝ ⅝ ⅞ ⅞ ⅞ ⅞ 1⅛ 1⅛ Outlet diameter inch ⅞ ⅞ 1⅛ 1⅛ 1⅜ 1⅝ 1⅝ 1⅝ Weight Shipping kg 373 399 433 459 668 750 799 858 Operating kg 376 404 439 466 678 762 813 874 Dimensions Length mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210 Width mm 850 850 850 850 850 850 850 850 Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 Acoustical data Sound power level 2 / 3* db(a) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79 Sound pressure level at 10 m 2 / 3** db(a) 39/37 39/37 41/39 42/40 47/45 50/48 50/48 50/48 Water Cooled Chiller & Heat Pump 1 Data refered to evaporator water temperature 12/7 C and condenser temperature 40 C. 2 Input power (only compressors). 3 BLN version. 4 ELN version. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. SP version: low pressure pump. HP version: high pressure pump.
144 Water cooled Chiller & Heat Pump Water Cooled Chiller & Heat Pump WQL/WQH/WQRC 524-1204 154-379 kw Water cooled Scroll 170-419 kw Plate 410A Technical features 8 sizes Cooling capacity from 154,3 to 379,2 kw Heating capacity from 170,2 to 418,5 kw 3 versions: WQL (Cooling only) WQH (Heat pump) WQRC (Condenserless) 2 acoustic option: BLN (Basic Low Noise) ELN (Extra Low Noise) Two refrigerant circuits Scroll compressors Accessories and options Desuperheater Differential pressure switch (standard) Electronic expansion valve (standard WQRC 1104-1204) Hydrokit with 1 or 2 pumps for evaporator and condenser Mechanical gauges Sequence phases control (standard) Softstart Water filter Water flow switch Operating limit (to be confirmed following selection software issue) WQL-WQH 524-1204 Leaving water temperature (cooling) Leaving water temperature (heating) Water C from +5 to +18 Water + glycol C -8 / +5 (with glycol and eletronic expansion valve); +5/+18 (standard) T K from 3 to 8 Water C from +25 to +55 T C from 3 to 15 Note: maximum % glycol (ethylenic or propilenic): 40%. WQRC 524-1204 Leaving water temperature (cooling) Water C from +5 to +18 Water + glycol C -8 / +5 (with glycol and eletronic expansion valve); +5/+18 (standard) T K from 3 to 8 Note: maximum % glycol (ethylenic or propilenic): 40%.
Water cooled Chiller & Heat Pump 145 Technical feature WQL/WQH 524-1204 524 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 154,3 181,8 208,9 232,6 265,8 295,6 338,0 379,2 Input power 1 kw 34,2 41,6 47,5 53,3 59,3 65,5 74,9 83,3 EER 1 kw/kw 4,51 4,37 4,40 4,36 4,48 4,51 4,51 4,55 Energy Efficiency class C C C C C C C C ESEER kw/kw 5,40 5,68 5,81 5,29 5,74 5,52 5,70 5,67 Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty/ 5 4 / Scroll Crankcase heater 5 W 90-90 90-90 90-120 140-140 140-140 140-140 140-140 140-140 Evaporator Qty/ 1 / Plate Water flow rate l/s 7,40 8,71 10,01 11,2 12,7 14,1 16,2 18,2 Water pressure drop kpa 26,7 26,6 31,5 36,3 18,7 22,8 17,8 18,4 Evaporator water connections Qty Victaulic Inlet/outlet diameter inch 2 1/2 2 1/2 2 1/2 2 1/2 4 4 4 4 Evaporator pump Qty 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Input power (SP version) kw 2,20 2,20 2,20 3,00 3,00 3,00 4,00 4,00 Available static pressure (SP version) kpa Refer to EDM graphics Input power (HP version) kw 3,00 3,00 4,00 4,00 5,50 5,50 5,50 7,50 Available static pressure (HP version) kpa Refer to EDM graphics Condenser Qty/ 1 / Plate Water flow rate l/s 8,97 10,6 12,2 13,6 15,5 17,2 19,7 22,0 Water pressure drop kpa 38.1 38,6 45,8 53,0 23,6 18,6 21,5 21,5 Condenser water connections Qty Victaulic Inlet/outlet diameter inch 2 1/2 2 1/2 2 1/2 2 1/2 4 4 4 4 Condenser pump Qty 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Input power (SP version) kw 2,20 3,00 3,00 4,00 4,00 5,50 5,50 5,50 Available static pressure (SP version) kpa Refer to EDM graphics Input power (HP version) kw 3,00 4,00 5,50 5,50 5,50 5,50 7,50 7,50 Available static pressure (HP version) kpa Refer to EDM graphics Desuperheater Qty/ 2 / Plate Heat recovery kw 22,1 28,4 36,1 42,0 50,4 68,3 78,1 81,9 Water flow rate l/s 1,05 1,35 1,73 2,01 2,41 3,26 3,73 3,91 Water pressure drop kpa 8,3 4,5 5,1 5,7 5,0 8,7 10,3 7,5 Weight Shipping 2 / 3 kg 858/961 929/1.032 1.110/1.213 1.279/1.382 1.266/1.369 1.363/1.466 1.449/1.552 1.541/1.644 Operating 2 / 3 kg 890/993 971/1.074 1.156/1.259 1.329/1.432 1.340/1.443 1.453/1.556 1.552/1.655 1.660/1.763 Dimensions Length mm 2.250 Width mm 850 2 /854 3 / 885 2 / 4-1.005 3 / 4 Height mm 1.845 2 / 1850 3 Acoustic data Sound power level 2 / 3* db(a) 81/75 82/76 85/79 87/81 89/83 90/84 90/84 90/84 Sound pressure level 2* / 3** db(a) 49/43 50/44 53/47 55/49 57/51 58/52 58/52 58/52 Water Cooled Chiller & Heat Pump 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 BLN version. 3 ELN version. 4 Only for movimentation. 5 Data for each refrigerant circuit. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
146 Water cooled Chiller & Heat Pump Technical feature WQH 524-1204 524 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 150,7 176,2 204,5 225,4 263,1 291,3 332,0 370,5 Input power 1 kw 34,9 42,7 48,3 54,3 59,8 66,4 76,2 85,2 EER 1 kw/kw 4,32 4,13 4,23 4,15 4,40 4,39 4,36 4,35 Energy Efficiency class C D D D C C C C ESEER kw/kw 5,35 5,59 5,71 5,25 5,66 5,46 5,63 5,59 Heating capacity 2 kw 170,2 201,1 231,8 256,5 295,6 331,0 376,6 418,5 Input power 2 kw 44,2 53,6 60,2 68,4 77,4 84,0 95,6 106,2 COP 2 kw/kw 3,85 3,75 3,85 3,75 3,82 3,94 3,94 3,94 Energy Efficiency class C D C D C C C C Power supply V/Ph/Hz 400/3/50 Refrigerant HFC 410A Number of refrigerant circuits 2 2 2 2 2 2 2 2 Compressor Qty / 6 4 / Scroll Crankcase heater 6 W 90-90 90-90 90-120 140-140 140-140 140-140 140-140 140-140 Internal heat exchanger Qty/ 1 / Plate Water flow rate - Cooling operation l/s 7,22 8,44 9,80 10,8 12,6 14,0 15,9 17,7 Water pressure drop - Cooling operation kpa 25,5 25,0 30,3 34,2 18,3 22,2 17,2 17,7 Water flow rate - Heating operation l/s 8,10 9,57 11,0 12,2 14,1 15,8 18,0 20,0 Water pressure drop - Heating operation kpa 31,6 31,7 37,9 43,2 22,6 28,0 21,6 22,1 Internal heat exchanger water connections Victaulic Inlet/outlet diameter inch 2 1/2 2 1/2 2 1/2 2 1/2 4 4 4 4 Internal heat exchanger pump Qty 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Input power (SP version) kw 2,20 2,20 2,20 3,00 3,00 3,00 4,00 4,00 Available static pressure (SP version) kpa Refer to EDM graphics Input power (HP version) kw 3,00 3,00 4,00 4,00 5,50 5,50 5,50 7,50 Available static pressure (HP version) kpa Refer to EDM graphics External heat exchanger Qty / 1 / Plate Water Flow Rate - Cooling operation l/s 8,83 10,4 12,0 13,3 15,4 17,1 19,5 21,7 Water Pressure Drop - Cooling operation kpa 37,1 37,2 44,6 50,9 23,3 18,3 21,0 20,9 Water Flow Rate - Heating operation l/s 10,3 12,0 13,9 15,3 17,8 20,0 22,7 25,2 Water Pressure Drop - Heating operation kpa 48,9 48,5 58,8 66,5 30,7 24,6 28,1 27,6 Desuperheater Qty / 2 / Plate Heat recovery kw 22,1 28,4 36,1 42,0 50,4 68,3 78,1 81,9 Water flow rate l/s 1,05 1,35 1,73 2,01 2,41 3,26 3,73 3,91 Water pressure drop kpa 8,3 4,5 5,1 5,7 5,0 8,7 10,3 7,5 Weight Shipping 3 / 4 kg 876/979 947/1.050 1.141/1.244 1.311/1.414 1.302/1.405 1.410/1.513 1.494/1.597 1.585/1.688 Operating 3 / 4 kg 909/1.012 989/1.092 1.187/1.290 1.360/1.463 1.376/1.479 1.500/1.603 1.598/1.701 1.704/1.807 Dimensions Length mm 2.250 Width mm 850 3 /854 4 / 885 3 / 5-1.005 4 / 5 Height mm 1.845 3 /1.850 4 Acoustic data Sound power level 3 / 4* db(a) 81/75 82/76 85/79 87/81 89/83 90/84 90/84 90/84 Sound pressure level 3* / 4** db(a) 49/43 50/44 53/47 55/49 57/51 58/52 58/52 58/52 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Data refers to 45 C leaving warm water temperature and 7 C ambient coil air temperature with 87% R.H., according EN14511 standard. 3 BLN version. 4 ELN version. 5 Only for movimentation. 6 Data for each refrigerant circuit. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water cooled Chiller & Heat Pump 147 Technical feature WQRC 524-1204 524 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 130,0 155,3 177,6 196,5 224,2 247,2 285,9 316,1 Input power 1 kw 42,9 51,1 59,0 65,8 74,4 82,5 94,6 105,8 Part load steps % 0-25-50-75-100 0-25-50-75-100 0-21-50-71-100 0-25-50-75-100 Power supply V/Ph/Hz 400/3/50 0-22-50-72-100 0-25-50-75-100 0-23-50-73-100 0-25-50-75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressore Qty / 5 4 / Scroll Crankcase heater 5 W 90-90 90-90 90-120 140-140 140-140 140-140 140-140 140-140 Internal heat exchanger Qty / 1 / Plate Water flow rate l/s 6,21 7,42 8,49 9,39 10,7 11,8 13,7 15,1 Water pressure drop kpa 19,3 19,6 23,0 26,2 13,5 16,2 12,9 13,0 Internal heat exchanger water connections Victaulic Inlet diameter inch 2 1/2 2 1/2 2 1/2 2 1/2 4 4 4 4 Internal heat exchanger pump Qty 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Input power (SP version) kw 2.20 2,20 2,20 3,00 3,00 3,00 4,00 4,00 Available static pressure (SP version) kpa Refer to EDM graphics Input power (HP version) kw 3.00 Available static pressure (HP version) kpa Refer to EDM graphics Remote condenser refrigerant connections To be brazed Inlet diameter inch 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 Outlet diameter inch 1 1/8 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 Weight Shipping 2 / 3 kg 754/857 791/894 965/1.068 1.138/1.241 1.153/1.256 1.203/1.306 1.279/1.382 1.333/1.436 Operating 2 / 3 kg 770/873 812/915 988/1.091 1.163/1.266 1.188/1.291 1.241/1.344 1.328/1.431 1.388/1.491 Dimensions Length mm 2.250 Width mm 850 2 /854 3 /885 2 / 4-1.005 3 / 4 Height mm 1.845 2 /1.850 3 Acoustic data Sound power level 2* db(a) 81 82 85 87 89 90 90 90 Sound pressure level 2** db(a) 49 50 53 55 57 58 58 58 Sound power level 3* db(a) 75 76 79 81 83 84 84 84 Sound pressure level 3** db(a) 43 44 47 49 51 52 52 52 Water Cooled Chiller & Heat Pump 1 Evaporator EWT/LWT 12 C/7 C, condensing temperature 50 C. 2 BLN version. 3 ELN version. 4 Only for movimentation. 5 Data for each refrigerant circuit. * Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. ** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
148 Water cooled Chiller & Heat Pump Water Cooled Chiller SyScrew 440-1550 Water EVO CO/HP/RC ENERGY EFFICIENCY COOLING MODE 2014 444-1.567 kw Shell & Tube 134a Report to performance data Water cooled Screw Technical features 15 sizes Cooling capacity from 444 to 1.567 kw 3 versions: CO (chiller) HP (heat pump) water side RC (condenserless) 2 acoustic versions: STD (Standard) S (Super Low Noise) 1/2 refrigerant circuit Screw compressors Shell & Tube evaporator and condenser Electronic expansion valve Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard for S version) Compressor stepless control Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter Water flow switch Operating limit (to be confirmed following selection software issue) Models SyScrew Water EVO CO SyScrew Water EVO HP SyScrew Water EVO RC Water C from 5 to 15 Evaporator Leaving water temperature Water + glycol C from -8 to 5 T K from 3 to 7 Leaving water temperature C from 25 a 45 from 25 to 60 - Condenser Condensing Temperature C - - da 30 a 63 Leaving water + glycol temperature K from +3 to +8 with tower water 15 with well water -
Water cooled Chiller & Heat Pump 149 Technical feature SyScrew 440-770 Water EVO CO 440 490 570 630 700 770 Cooling capacity 1 kw 444,3 494,4 570,4 636,2 708,5 787,1 Power input 1 kw 87,9 97,8 112,4 125,4 140,2 155,7 EER 1 5,06 5,05 5,07 5,07 5,05 5,06 Energy efficiency class A A A A A A ESEER 6,27 6,27 6,29 6,29 6,27 6,27 Part load steps % 50-75-100 Refrigerant HFC 134a Number of refrigerant circuits 1 Compressor Screw Qty 1 Startup type S/Δ Evaporator Shell & Tube (Pure counterflow) Qty 1 Water flow m 3 /h 76,7 85,3 98,5 109,9 122,2 135,8 Water pressure drop kpa 42,9 30,2 52,0 64,7 30,2 37,2 Connection type Victaulic Inlet/outlet diameter inch 6 6 6 6 8 8 Condenser Shell & Tube (Pure counterflow) Qty 1 Water flow m 3 /h 91,2 101,5 117,0 130,6 145,5 161,6 Water pressure drop kpa 52,5 50,7 54,7 34,3 42,5 51,1 Connection type Female gas threaded Inlet/outlet diameter inch 4 4 5 5 5 5 Weight / STD version Shipping kg 2.502 2.531 2.694 2.800 3.178 3.245 Operating kg 2.683 2.718 2.911 3.033 3.516 3.590 Dimensions / STD version Length mm 3.620 4.210 4.180 Width mm 1.350 Height mm 1.650 Acoustic data / STD version Sound power level 2 db(a) 95 95 95 95 95 95 Sound pressure level 3 db(a) 76 76 76 76 76 76 Weight / S version Shipping kg 2.682 2.711 2.874 2.980 3.358 3.425 Operating kg 2.863 2.898 3.091 3.213 3.696 3.770 Dimensions / S version Length mm 3.620 4.210 4.180 Width mm 1.350 Height mm 1.750 Acoustic data / S version Sound power level 2 db(a) 85 85 85 85 85 85 Sound pressure level 3 db(a) 66 66 66 66 66 66 Water Cooled Chiller & Heat Pump 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
150 Water cooled Chiller & Heat Pump Technical feature SyScrew 860-1550 Water EVO CO 860 920 990 1070 1130 1220 1280 1400 1550 Cooling capacity 1 kw 875,5 936,0 998,6 1.071,4 1.132,9 1.224,1 1.285,2 1.428,5 1.567,0 Power input 1 kw 173,1 185,2 197,6 211,7 223,8 241,0 253,9 282,4 309,9 EER 1 5,06 5,05 5,05 5,06 5,06 5,08 5,06 5,06 5,06 Energy efficiency class A C A A A A A A A ESEER 6,37 6,37 6,39 6,42 6,42 6,43 6,37 6,38 6,38 Part load steps % 25-50-62-75-87-100 Refrigerant HFC 134a Number of refrigerant circuits 2 Compressor Screw Qty 2 Startup type S/Δ Evaporator Shell & Tube (Pure counterflow) Qty 1 Water flow m 3 /h 151,0 161,5 172,3 184,9 195,6 211,0 221,6 246,7 270,8 Water pressure drop kpa 41,6 47,6 42,6 47,6 53,2 32,3 35,6 62,1 74,8 Connection type Victaulic Inlet/outlet diameter inch 8 8 8 8 8 8 8 10 10 Condenser Shell & Tube Qty 2 Water flow m 3 /h 179,7 192,2 205,0 219,9 232,5 251,1 263,8 293,4 321,8 Water pressure drop 1 circuit kpa 51,0 51,8 51,8 52,9 54,0 56,0 54,6 42,2 50,7 Water pressure drop 2 circuit 51,0 50,9 51,8 54,0 54,0 55,3 54,6 42,2 50,7 Connection type Female gas threaded Inlet/outlet diameter inch 4 4 4 4 / 5 5 5 5 5 5 Weight / STD version Shipping kg 5.085 5.115 5.227 5.361 5.466 5.557 5.599 6.093 6.188 Operating kg 5.540 5.576 5.787 5.909 6.016 6.087 6.136 6.754 6.849 Dimensions / STD version Length mm 4.400 4.600 4.650 5.350 Width mm 1.520 Height mm 1.710 Acoustic data / STD version Sound power level 2 db(a) 98 98 98 98 98 98 98 98 98 Sound pressure level 3 db(a) 79 79 79 79 79 79 79 79 79 Weight / S version Shipping kg 5.445 5.475 5.587 5.721 5.826 5.917 5.959 6.453 6.548 Operating kg 5.900 5.936 6.147 6.269 6.376 6.447 6.496 7.114 7.209 Dimensions / S version Length mm 4.400 4.600 4.650 5.350 Width mm 1.520 Height mm 1.710 Acoustic data / S version Sound power level 2 db(a) 89 89 89 89 89 89 89 89 89 Sound pressure level 3 db(a) 70 70 70 70 70 70 70 70 70 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water cooled Chiller & Heat Pump 151 Technical feature SyScrew 440-770 Water EVO HP 440 490 570 630 700 770 Cooling Capacity 1 3 kw 383,4 433,6 498,1 554,5 619,1 676,8 Power input 1 3 kw 104,3 115,6 136,4 153,4 172,8 185,2 Heating Capacity 1 3 kw 487,7 549,1 634,6 707,9 791,9 862,1 COP 1 3 4,68 4,75 4,65 4,61 4,58 4,65 Energy Efficiency Class A A A A A A Cooling Capacity 2 3 kw 339,5 383,8 441,3 491,4 548,0 599,1 Total Input Power 2 3 kw 117,1 130,3 152,2 172,0 195,5 208,9 Heating Capacity 2 3 kw 456,6 514,1 593,5 663,4 743,5 808,0 COP 2 3 3,90 3,95 3,90 3,86 3,80 3,87 Part Load Steps % 50-75-100 Start-up SD SD SD SD SD SD Refrigerant HFC 134a Number of Refrigerant Circuits 1 1 1 1 1 1 Compressor Qty / 1 / Screw Internal heat exchanger (Evaporator) Qty / 1 / Shell & tube (Pure counterflow) Connection type Victaulic Inlet/outlet diameter inch 6 6 6 6 8 8 Water flow rate 1 m 3 /h 110,4 124,8 143,5 159,4 178,1 194,8 Water pressure drop 1 kpa 89 65 110 136 64 77 Water flow rate 2 m 3 /h 97,5 110,3 126,8 141,1 157,4 172,1 Water pressure drop 2 kpa 69 50 86 107 50 60 External heat exchanger (Condenser) Qty / 1 / Shell & tube Connection type Victaulic Inlet/outlet diameter inch 4 4 5 5 5 5 Water flow rate (total) 1 m 3 /h 83,4 94,0 108,4 120,7 135,6 147,5 Water pressure drop cond 1 1 kpa 44 44 47 29 37 43 Water pressure drop cond 2 1 kpa - - - - - - Water flow rate (total) 2 m 3 /h 48,8 55,0 63,4 70,8 79,6 86,5 Water pressure drop cond 1 2 kpa 15 15 16 10 13 15 Water pressure drop cond 2 2 kpa - - - - - - Acoustic Data / STD version Sound power level 4 db(a) 95 95 95 95 95 95 Sound pressure level 5 db(a) 76 76 76 76 76 76 Acoustic Data / S version Sound Power Level 4 db(a) 85 85 85 85 85 85 Sound Pressure Level 5 db(a) 66 66 66 66 66 66 Dimensions / STD version Lenght mm 3.620 3.620 4.210 4.210 4.180 4.180 Width mm 1.350 1.350 1.350 1.350 1.350 1.350 Height mm 1.650 1.650 1.650 1.650 1.650 1.650 Dimensions / S version Lenght mm 3.620 3.620 4.210 4.210 4.180 4.180 Width mm 1.350 1.350 1.350 1.350 1.350 1.350 Height mm 1.750 1.750 1.750 1.750 1.750 1.750 Weight / STD version Shipping kg 2.509 2.538 2.701 2.807 3.185 3.252 Operating kg 2.690 2.725 2.918 3.040 3.523 3.597 Weight / S version Shipping kg 2.703 2.732 2.895 3.001 3.379 3.446 Operating kg 2.884 2.919 3.112 3.234 3.717 3.791 Water Cooled Chiller & Heat Pump 1 Heating mode conditions: evaporator EWT/LWT 10 C/7 C, condenser EWT/LWT 40 C/45 C. 2 Heating mode conditions: evaporator EWT/LWT 10 C/7 C, condenser EWT/LWT 47 C/55 C. 3 NET value. According to standard EN 14511-3:2011. 4 Sound power levels refers to standard ISO 3744 and Eurovent 8/1 for units certified. Units at fully loaded conditions. 5 Sound pressure levels refers to unit in free field on refletive surface at 1m. Values derived from sound power levels (standard ISO 3744 with parallepiped shape).
152 Water cooled Chiller & Heat Pump Technical feature SyScrew 860-1550 Water EVO HP 860 920 990 1070 1130 1220 1280 1400 1550 Cooling Capacity 1 3 kw 755,9 813,8 874,6 934,6 985,3 1.069,6 1.122,1 1.241,5 1.341,5 Power Input 1 3 kw 204,3 219,4 234,6 254,7 271,7 290,3 304,8 351,6 373,1 Heating Capacity 1 3 kw 960,2 1.033,2 1.109,2 1.189,3 1.257,0 1.359,9 1.426,9 1.593,1 1.714,6 COP 1 3 4,70 4,71 4,73 4,67 4,63 4,68 4,68 4,53 4,60 Energy Efficiency Class A A A A A A A A A Cooling Capacity 2 3 kw 669,3 720,7 774,4 827,8 872,7 946,6 993,3 1.100,0 1.189,1 Total Input Power 2 3 kw 230,2 246,6 264,0 286,2 305,1 327,7 343,8 395,2 417,5 Heating Capacity 2 3 kw 899,5 967,3 1.038,4 1.114,0 1.177,8 1.274,3 1.337,1 1.495,2 1.606,6 COP 2 3 3,91 3,92 3,93 3,89 3,86 3,89 3,89 3,78 3,85 Part Load Steps % 25-50-62-75-87-100 Start-up SD SD SD SD SD SD SD SD SD Refrigerant HFC 134a Number of Refrigerant Circuits 2 2 2 2 2 2 2 2 2 Compressor Qty / 2 / Screw Internal heat exchanger (Evaporator) Qty / 1 / Shell & tube (Pure counterflow) Connection type Victaulic Inlet/outlet diameter inch 8 8 8 8 8 8 8 10 10 Water flow rate 1 m 3 /h 217,6 234,2 251,7 269,0 283,6 307,9 323,0 357,0 386,0 Water pressure drop 1 kpa 86 100 91 101 112 69 76 130 152 Water flow rate 2 m 3 /h 192,2 207,0 222,4 237,7 250,6 271,8 285,2 315,8 341,4 Water pressure drop 2 kpa 67 78 71 79 87 54 59 102 119 External heat exchanger (Condenser) Qty / 2 / Shell & tube Connection type Victaulic Inlet/outlet diameter inch 4 4 4 4 / 5 5 5 5 5 5 Water flow rate (total) 1 m 3 /h 164,2 176,6 189,7 203,3 214,7 232,9 244,3 271,9 292,3 Water pressure drop cond 1 1 kpa 43 44 44 45 46 48 47 36 42 Water pressure drop cond 2 1 kpa 43 43 44 46 46 48 47 36 42 Water flow rate (total) 2 m 3 /h 96,3 103,4 111,1 119,1 125,9 136,5 143,2 159,7 171,5 Water pressure drop cond 1 2 kpa 15 15 15 15 16 16 16 12 14 Water pressure drop cond 2 2 kpa 15 15 15 16 16 16 16 12 14 Acoustic Data / STD version Sound power level 4 db(a) 98 98 98 98 98 98 98 98 98 Sound pressure level 5 db(a) 79 79 79 79 79 79 79 79 79 Acoustic Data / S version Sound power level 4 db(a) 89 89 89 89 89 89 89 89 89 Sound pressure level 5 db(a) 70 70 70 70 70 70 70 70 70 Dimensions / STD version Lenght mm 4.400 4.400 4.600 4.650 4.650 4.650 4.650 5.350 5.350 Width mm 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 Height mm 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710 Dimensions / S version Lenght mm 4.650 4.650 4.650 4.650 4.650 4.650 4.650 5.350 5.350 Width mm 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 Height mm 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770 Weight / STD version Shipping kg 5.124 5.154 5.266 5.400 5.505 5.596 5.638 6.132 6.227 Operating kg 5.579 5.615 5.826 5.948 6.055 6.126 6.175 6.793 6.888 Weight / S version Shipping kg 5.511 5.541 5.653 5.787 5.892 5.983 6.025 6.519 6.614 Operating kg 5.966 6.002 6.213 6.335 6.442 6.513 6.562 7.180 7.275 1 Heating mode conditions: evaporator EWT/LWT 10 C/7 C, condenser EWT/LWT 40 C/45 C. 2 Heating mode conditions: evaporator EWT/LWT 10 C/7 C, condenser EWT/LWT 47 C/55 C. 3 NET value. According to standard EN 14511-3:2011. 4 Sound power levels refers to standard ISO 3744 and Eurovent 8/1 for units certified. Units at fully loaded conditions. 5 Sound pressure levels refers to unit in free field on refletive surface at 1m. Values derived from sound power levels (standard ISO 3744 with parallepiped shape).
Water cooled Chiller & Heat Pump 153 Technical feature SyScrew 440-770 Water EVO RC 440 490 570 630 700 770 Cooling capacity 1 kw 386,3 435,7 502,8 561,0 621,9 680,6 Power input 1 kw 101,2 113,3 131,4 147,4 170,4 181,5 EER 1 3,82 3,85 3,83 3,81 3,65 3,75 Part load steps % 50-75-100 Refrigerant HFC 134a Number of refrigerant circuits 1 Compressor Screw Qty 1 Startup type S/Δ Evaporator Shell & Tube (Pure counterflow) Qty 1 Water flow m 3 /h 66,4 74,9 86,5 96,5 107,0 117,1 Water pressure drop kpa 32,2 23,3 40,0 49,9 23,1 27,7 Connection type Victaulic Inlet/outlet diameter inch 6 6 6 6 8 8 Weight / STD version Shipping kg 2.152 2.162 2.278 2.298 2.669 2.709 Operating kg 2.295 2.305 2.449 2.469 2.945 2.985 Dimensions / STD version Length mm 3.620 4.210 4.180 Width mm 1.350 Height mm 1.620 Acoustic data / STD version Sound power level 2 db(a) 95 95 95 95 95 95 Sound pressure level 3 db(a) 76 76 76 76 76 76 Weight / S version Shipping kg 2.332 2.342 2.458 2.478 2.849 2.889 Operating kg 2.475 2.485 2.629 2.649 3.125 3.165 Dimensions / S version Length mm 3.620 4.210 4.180 Width mm 1.350 Height mm 1.620 Acoustic data / S version Sound power level 2 db(a) 85 85 85 85 85 85 Sound pressure level 3 db(a) 66 66 66 66 66 66 Water Cooled Chiller & Heat Pump 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
154 Water cooled Chiller & Heat Pump Technical feature SyScrew 860-1550 Water EVO RC 860 920 990 1070 1130 1220 1280 1400 1550 Cooling capacity 1 kw 760,8 820,0 880,4 941,7 993,6 1.074,2 1.127,6 1.253,8 1.357,3 Power input 1 kw 199,5 213,2 228,7 247,5 263,2 285,5 299,1 340,5 357,8 EER 1 3,81 3,85 3,85 3,80 3,77 3,76 3,77 3,68 3,79 Part load steps % 25-50-62-75-87-100 Refrigerant HFC 134a Number of refrigerant circuits 2 Compressor Screw Qty 2 Startup type S/Δ Evaporator Shell & Tube Qty 1 Water flow m 3 /h 130,9 141,0 151,4 162,0 170,9 184,8 194,0 215,6 233,5 Water pressure drop kpa 31,2 36,3 32,9 36,5 40,6 24,7 27,3 47,4 55,6 Connection type Victaulic Inlet/outlet diameter inch 8 8 8 8 8 8 8 10 10 Weight STD version Shipping kg 4.386 4.396 4.487 4.574 4.634 4.700 4.720 5.034 5.114 Operating kg 4.765 4.775 4.959 5.032 5.092 5.131 5.151 5.557 5.637 Dimensions STD version Length mm 4.400 4.600 4.650 5.350 Width mm 1.520 Height mm 1.710 Acoustic data STD version Sound power level 2 db(a) 98 98 98 98 98 98 98 98 98 Sound pressure level 3 db(a) 79 79 79 79 79 79 79 79 79 Weight S version Shipping kg 4.746 4.756 4.847 4.934 4.994 5.060 5.080 5.394 5.474 Operating kg 5.125 5.135 5.319 5.392 5.452 5.491 5.511 5.917 5.997 Dimensions S version Length mm 4.400 4.600 4.650 5.350 Width mm 1.520 Height mm 1.710 Acoustic data S version Sound power level 2 db(a) 89 89 89 89 89 89 89 89 89 Sound pressure level 3 db(a) 70 70 70 70 70 70 70 70 70 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Free-cooling module SysFreeCool 100-550 kw Free-cooling Free-cooling
156 Free-cooling Free-cooling module SysFreeCool 100-550 kw Free-cooling Technical feature 10 sizes Cooling capacity from 100 to 550 kw Freecooling option is developed in two versions: Slave Stand-alone 2 acoustic versions: - (Basic Low Noise) L (Low Noise) 2 fans versions: EC Version (Inverter Fans) HPF Version (High Pressure Fans Accessories and options Set point timer/clock card as standard Fan speed control as standard Sequence phase control as standard Power supply without neutral Hour meter as standard Main switch ModBus protocol kit Automatic circuit breaker E-coating for AL/CU fins Coils with cooper fins Coil grilles Free-cooling grilles High static pressure fan motors (HPF Version) Brushless fan motors (EC Version) Remote ON/OFF control Remote keyboard panel Water filter Operating limit (to be confirmed following selection software issue) SysFreeCool 12 14 22 23 24 32 33 34 43 44 Brine Minimum temperature 1 C -10 Maximum operating pressure bar 6 Min./Max. Outdoor air temperature C -20 to +50 Ambient External Standard fans Pa 0 static pressure High pressure fans Pa < 120 Power supply voltage 2 V 400 V, 3 Ø, 50 Hz (nominal) * Operating limits refer to free-cooling module. Concerning chiller to be matched to free-cooling module, operating limit can be found inside chiller correspondent chapter 1 Liquid with appropriate % of glycol. 2 Voltage 400V +/- 10%.
Free-cooling 157 Configuration Following modules are available in order to cover a wide capacity range: 1V: equipped with two coils and two fan motors 2V: equipped with four coils and four fan motors 3V: equipped with six coils and six fan motors 4V: equipped with eight coils and eight fan motors Each module is be available in further versions, according coil row number, sound level emission Following table is summarizing allowed combination between free-cooling modules and SyScroll Air range. The table is valid for Slave version SyScroll Air CO Free-cooling module SyScroll Air FC Assembly view Size Assembly view Size Assembly view 240 270 290 320 23 24 32 Free-cooling 360 420 470 540 33 34 + = 33 34 590 660 43 44 SyScroll Air EVO CO Free-cooling module SyScroll Air EVO FC Assembly view Size Assembly view Size Assembly view 200 22 230 260 280 + = 23 24 32 300 330 360 23 24 Following picture is showing cooling capacity field where it is possible to have stand-alone, slave or both configuration V VV VVV VVVV Stand-alone Slave / Stand-alone 85 200 300 400 550 Cooling Capacity (kw)
158 Free-cooling Technical feature SysFreeCool_ - (STD -HPF) 12 14 22 23 24 Nominal capacity 1 kw 101 156 206 245 275 Nominal Water Flow m 3 /h 19,0 29,4 38,7 46,0 51,7 Total pressure drop 1 kpa 44 83 74 43 49 Fans Number of fans 2 2 4 4 4 Nominal speed rpm 900 900 900 900 900 Total airflow m 3 /h 45.400 41.000 90.000 85.200 80.400 Total input power kw 4,2 4,2 8,4 8,4 8,4 Total input power * kw 6,2 6,2 12,4 12,4 12,4 Water Connections Male GAS Threaded Inlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 Outlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 Water Flow Range Min water flow m 3 /h 11,1 12,5 17,4 27,2 28,7 Max water flow m 3 /h 30,0 33,8 47,2 73,6 77,8 Weight Shipping kg 624 664 912 965 1.005 Operating kg 669 733 1.002 1.075 1.139 Dimensions Length mm 2.146 2.124 Width mm 1.097 2.146 Height mm 2.519 2.519 Acoustical data Sound power level 2 db(a) 88 88 91 91 91 Sound pressure level at 10 m 3 db(a) 56 56 59 59 59 SysFreeCool_ - (STD -HPF) 32 33 34 43 44 Nominal capacity 1 kw 309 367 413 490 550 Nominal Water Flow m 3 /h 58,0 69,0 77,5 92,0 103,4 Total pressure drop 1 kpa 70 51 57 43 49 Fans Number of fans 6 6 6 8 8 Nominal speed rpm 900 900 900 900 900 Total airflow m 3 /h 135.000 127.800 120.600 170.400 160.800 Total input power kw 12,6 12,6 12,6 16,8 16,8 Total input power * kw 18,6 18,6 18,6 24,8 24,8 Water Connections Male GAS Threaded Victaulic Inlet Diameter inch 3 4 4 5 5 Outlet Diameter inch 3 4 4 5 5 Water Flow Range Min water flow m 3 /h 26,8 37,5 39,7 54,3 57,5 Max water flow m 3 /h 72,6 101,6 107,4 147,2 155,6 Weight Shipping kg 1.336 1.404 1.464 1.800 1.880 Operating kg 1.466 1.574 1.670 2.070 2.198 Dimensions Length mm 3.176 4.228 Width mm 2.146 2.146 Height mm 2.519 2.519 Acoustical data Sound power level 2 db(a) 93 93 93 94 94 Sound pressure level at 10 m 3 db(a) 61 61 61 62 62 1 Data refers to 15 ( C) return brine temperature, 10 ( C) leaving brine temperature, 0 ( C) outdoor air temperature; 30% EG. 2 Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744. 3 Sound pressure levels refer to ISO Standard 3744, parallelepiped shape.
Free-cooling 159 Technical feature SysFreeCool_ L- (STD -HPF) 12 14 22 23 24 Nominal capacity 1 kw 84,4 123,5 170,3 197,0 215,9 Nominal Water Flow m 3 /h 15,9 23,2 32,0 37,0 40,6 Total pressure drop 1 kpa 31 52 50 28 30 Fans Number of fans 2 2 4 4 4 Nominal speed rpm 700 700 700 700 700 Total airflow m 3 /h 34.000 30.000 66.400 62.000 58.000 Total input power kw 2,3 2,3 4,6 4,6 4,6 Water Connections Male GAS Threaded Inlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 Outlet Diameter inch 2 1/2 2 1/2 2 1/2 3 3 Water Flow Range Min water flow m 3 /h 11,1 12,5 17,4 27,2 28,7 Max water flow m 3 /h 30,0 33,8 47,2 73,6 77,8 Weight Shipping kg 624 664 912 965 1.005 Operating kg 669 733 1.002 1.075 1.139 Dimensions Length mm 2.146 2.124 Width mm 1.097 2.146 Height mm 2.519 2.519 Acoustical data Sound power level 2 db(a) 79 79 82 82 82 Sound pressure level at 10 m 3 db(a) 47 47 50 50 50 Free-cooling 1 Data refers to 15 ( C) return brine temperature, 10 ( C) leaving brine temperature, 0 ( C) outdoor air temperature; 30% EG. 2 Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744. 3 Sound pressure levels refer to ISO Standard 3744, parallelepiped shape.
160 Free-cooling Technical feature SysFreeCool_ L- (STD -HPF) 32 33 34 43 44 Nominal capacity 1 kw 255,4 295,5 323,8 394,0 431,8 Nominal Water Flow m 3 /h 48,0 55,5 60,8 74,0 81,1 Total pressure drop 1 kpa 48 33 35 28 30 Fans Number of fans 6 6 6 8 8 Nominal speed rpm 700 700 700 700 700 Total airflow m 3 /h 99.600 93.000 87.000 124.000 116.000 Total input power kw 6,9 6,9 6,9 9,2 9,2 Water Connections Male GAS Threaded Victaulic Inlet Diameter inch 3 4 4 5 5 Outlet Diameter inch 3 4 4 5 5 Water Flow Range Min water flow m 3 /h 26,8 37,5 39,7 54,3 57,5 Max water flow m 3 /h 72,6 101,6 107,4 147,2 155,6 Weight Shipping kg 1.336 1.404 1.464 1.800 1.880 Operating kg 1.466 1.574 1.670 2.070 2.198 Dimensions Length mm 3.176 4.228 Width mm 2.146 2.146 Height mm 2.519 2.519 Acoustical data Sound power level 2 db(a) 84 84 84 85 85 Sound pressure level at 10 m 3 db(a) 52 52 52 53 53 1 Data refers to 15 ( C) return brine temperature, 10 ( C) leaving brine temperature, 0 ( C) outdoor air temperature; 30% EG. 2 Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744. 3 Sound pressure levels refer to ISO Standard 3744, parallelepiped shape.
Condensing unit SyScroll 20-35 Air RE 22-36 kw 410A Scroll SyScroll 140-360 Air RE 165-395 kw 410A Scroll 43-85 kw 410A Scroll SysAqua 25-125 C 32-136 kw 410A Scroll 94-142 kw 410A Scroll AQVC 85-140 VLC 604-1204 174-347 kw 410A Scroll SyScroll 240-660 Air RE 92-151 kw 410A Scroll 266-727 kw 410A Scroll SyScroll 85-135 Air RE Condensing unit SyScroll 40-75 Air RE
162 Condensing unit Condensing unit SyScroll 20-35 Air RE 22-36 kw Air cooled Scroll 410A Technical features 4 sizes Cooling capacity from 22,1 to 36,2 kw One scroll compressor New control Scroll compressors Accessories and options Automatic circuit breaker (standard) Coil grilles Coils treatment Desuperheater Fan speed control (standard) Power factor corrector capacitors Sequence phases control (standard) Softstart SyScroll 20-35 Air RE - Cooling Operation Air Temperature ( C) 60 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-12 -10-8 -6-4 -2 0 2 4 6 8 10 12 14 Evaporating Temperature ( C) Operating limit (to be confirmed following selection software issue) SyScroll 20-35 Air RE Evaporating temperature 2 C from -12 to +14 Ambient Air temperature - 1 C refer to graphic
Condensing unit 163 Technical feature SyScroll 20-35 Air RE 20 25 30 35 Cooling Capacity (1) kw 22,1 26,4 29,9 36,2 Input Power (1) kw 7,23 7,96 9,56 12,3 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Crankcase heater W 70 90 90 90 Condenser Qty 1 Fan Number 2 Axial Air Flow Rate mc/h 10.957 10.425 10.425 9.919 Total Input Power kw 0,54 0,54 0,54 0,55 Refrigerant connection To be brazed Liquid diameter inch 1 1/2 Gas diameter inch 7/8" 1" 1/8 Weight Shipping kg 228 259 263 278 Dimensions Length mm 1.477 1.477 1.477 1.477 Width mm 539 539 539 539 Height mm 1.615 1.615 1.615 1.615 Acoustical data Sound Power Level db(a) 73 74 74 75 Sound Pressure Level* db(a) 41 42 42 43 Condensing unit (1) Data refers to 7 C evaporating temperature and 35 C condenser inlet air temperature (*) Sound pressure level at 10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
164 Condensing unit Condensing unit SyScroll 40-75 Air RE 25-37 kw Air cooled Scroll 410A Technical features 6 sizes Cooling capacity from 43,2 to 84,5 kw 2 versions: STD (Standard) HPF (High Pressure Fans) 2 acoustic versions: - (Basic Low Noise) S (Extra Low Noise) One refrigerant circuit Scroll compressors Accessories and options Automatic circuit breaker Coils treatments Compressors acoustic box as standard Compressors jackets (standard on S) Desuperheater Fan speed control (standard) Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles (standard) SyScroll 40-75 Air RE - Air Temperature ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 -14-13-12-11-10-9 -8-7 -6-5 -4-3 -2-1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Evaporating Temperature ( C) SyScroll 40-75 Air RE S version 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 -14-13-12-11-10-9 -8-7 -6-5 -4-3 -2-1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Air Temperature ( C) Evaporating Temperature( C) SyScroll 40-75 Air RE HPF version Air Temperature ( C) 55 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 -14-13-12-11-10-9 -8-7 -6-5 -4-3 -2-1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Evaporating Temperature ( C) Operating limit (to be confirmed following selection software issue) 40-50 60-75 SyScroll 40-75 Air RE Evaporating limit 1 C from -13 to +14-2 C from -18 to +44 Ambient Air temperature S 2 C from -18 to +40 HPF C refer to graphic 1 Till to air temperature -12, between -3 C to +40 C with fan speed control. 2 Till to air temperature -18 C with fan speed control.
Condensing unit 165 Technical feature SyScroll 40-75 Air RE 40 45 50 60 65 75 Cooling capacity 1 kw 43,2 48,8 56,9 67,4 73,8 84,5 Power input 1 kw 13,0 15,3 17,8 18,7 21,6 26,3 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Crankcase heater W 90 Condenser Qty 1 Frontal surface mm 2.160x1.200 2.160x1.200 2.160x1.200 2.650x1.200 2.650x1.200 2.650x1.200 Number of rows 2 2 3 3 3 3 Fan Qty 1 Air flow m 3 /h 14.000 14.000 13.200 21.100 21.100 21.100 Speed rpm/min 680 680 680 900 900 900 Power input kw 0,98 0,98 0,98 2,00 2,00 2,00 Refrigerant connection To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅞ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Weight Shipping kg 391 399 422 456 466 469 Dimensions Length mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 80,5 81,0 81,0 85,5 85,6 85,8 Sound pressure level 3 db(a) 48,9 49,4 49,4 53,8 53,9 54,1 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
166 Condensing unit Technical feature SyScroll 40-75 Air RE S 40 45 50 60 65 75 Cooling capacity 1 kw 41,6 46,7 54,0 64,9 70,7 80,6 Power input 1 kw 13,7 16,3 19,1 19,7 22,8 28,1 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Crankcase heater W 90 Condenser Qty 1 Frontal surface mm 2.160x1.200 2.160x1.200 2.160x1.200 2.650x1.200 2.650x1.200 2.650x1.200 Number of rows 2 2 3 3 3 3 Fan Qty 1 Air flow m 3 /h 11.000 11.000 10.300 16.000 16.000 16.000 Speed rpm/min 530 530 530 720 720 720 Power input kw 0.57 0.57 0.57 1.27 1.27 1.27 Refrigerant connection To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅞ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Weight Shipping kg 391 399 422 456 466 469 Dimensions Length mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.580 1.580 1.580 1.580 1.580 1.580 Acoustical data Sound power level 2 db(a) 74,0 75,3 75,3 78,0 78,5 79,0 Sound pressure level 3 db(a) 42,4 43,7 43,7 46,3 46,8 47,3 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Condensing unit 167 Technical feature SyScroll 40-75 Air RE HPF 40 45 50 60 65 75 Cooling capacity 1 kw 45,8 52,1 61,3 68,4 75,2 85,9 Power input 1 kw 11,9 13,9 16,0 18,3 21,1 25,6 Part load steps % 0-50-100 0-50-100 0-50-100 0-44-56-100 0-50-100 0-50-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct Refrigerant HFC 410A Number of refrigerant circuits 1 Compressor Qty 2 Scroll Crankcase heater W 90 Condenser Qty 1 Frontal surface mm 2.160x1.200 2.160x1.200 2.160x1.200 2.650x1.200 2.650x1.200 2.650x1.200 Number of rows 2 2 3 3 3 3 Fan Qty 1 Air flow m 3 /h 25.284 25.284 24.300 25.284 25.284 25.284 Speed rpm/min 1.110 1.110 1.110 1.110 1.110 1.110 Power input kw 2.67 2.67 2.67 2.67 2.67 2.67 Refrigerant connection To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅞ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Weight Shipping kg 391 399 422 456 466 469 Dimensions Length mm 1.750 1.750 1.750 2.200 2.200 2.200 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 1.685 1.685 1.685 1.685 1.685 1.685 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard.
168 Condensing unit Condensing unit SysAqua 25-125 C 32-136 kw Air cooled Scroll 410A Technical features Coolling only 32 to 136 kw R410A refrigerant Units are optimized for partial load operation High ESEER 2 compressors fitted in tandem for all the range with two capacity steps Sizes 25 to 125, three capacity steps with an immediate return on investment versus the inverter units Low noise version supplied as standard, extra low noise version for the XLS units (AQUAC 45-125 only) Refrigerant circuit is completely closed in a separate compartment in order to reduce noise level (sizes 25 to 40) Great accessibility to internal components for service mantenance Wide operating limits Fan speed control for low ambient operation in cooling mode down to -10 C as STD Phase sequence monitor supplied as standard Small footprint, allowing shipping and handling costs to be saved, units find easily a place to be installed Suction and liquid line shut-off valve as STD, Ideal to be connected with air handling unit Accessories and options Condenser protective grid Reinforced acoustic insulation (XLS version) Coil with epoxy treatment LP/HP gauges Power supply without neutral kit Soft starter Anti-vibration rubber pads Operating limit (to be confirmed following selection software issue) Condenser inlet temperature ( C) 55 50 45 40 35 30 25 20 15 10 5 0 Running with fan speed control STD -5-10 -15-14 -13-12 -11-10 -9-8 -7-6 -5-4 -3-2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Evaporating temperature ( C)
Condensing unit 169 Technical feature SysAqua 25-125 C 25 30 35 40 45 Cooling capacity kw 32,5 33,7 43,1 44,8 57,3 Power input kw 9,1 9,8 13,9 14,1 17,4 Total EER 100% 1 3,57 3,44 3,10 3,18 3,29 Power supply 400V/3~N/50Hz Startup type Direct Maximum operating current A 22,5 24,5 32 34 41 Startup current A 64 77,5 118,5 119,5 134 Refrigerant (units are delivered with a neutral charge of Nitrogen) HFC 410A Number of refrigerant circuits 1 Compressors Qty 2 2 2 2 2 Scroll Part load steps % 0/50/100 0/50/100 0/50/100 0/50/100 0/50/100 Crankcase heater W 2 x 40 2 x 70 2 x 70 2 x 70 2 x 90 Coil Qty 1 1 1 1 1 Total coil face area per coil m 2 2,4 2,4 2,8 2,8 4,2 Fan Qty 1 1 1 1 1 Air flow m³/h 13.000 13.000 16.000 16.000 22.500 Speed rpm 930 930 650 650 900 Power input each fan W 900 900 930 930 2.100 Refrigerant Connections Liquid line inch 5/8 5/8 5/8 5/8 5/8 Suction line inch 1 1/8 1 1/8 1 1/8 1 1/8 1 5/8 Dimensions Length mm 1.000 1.000 1.000 1.000 2.180 Width mm 1.000 1.000 1.000 1.000 1.160 Height mm 1.983 1.983 1.983 1.983 1.986 Weight Operating kg 260 270 280 280 490 Acoustical data Sound power level db(a) 75 75 76 76 80 Condensing unit 1 Air: 35 C. Evaporating temperature: +7 C.
170 Condensing unit Technical feature SysAqua 25-125 C 55 65 75 90 105 125 Cooling capacity kw 64,5 72,3 79,3 103,9 119,6 136,4 Power input kw 20,2 22,5 25,3 35 38,8 47,1 Total EER 100% 1 3,19 3,21 3,13 2,97 3,08 2,89 Power supply 400V/3~N/50Hz Startup type Direct Maximum operating current A 45 59,5 64,5 79,5 87,5 103,5 Startup current A 141 201,5 206,5 266,5 313,5 351,5 Refrigerant (units are delivered with a neutral charge of Nitrogen) HFC 410A Number of refrigerant circuits 1 Compressors Qty 2 2 2 2 2 2 Scroll Part load steps % 0/45/55/100 0/40/60/100 0/45/55/100 0/45/55/100 0/40/60/100 0/33/67/100 Crankcase heater W 2 x 90 2 x 90 2 x 90 90/140 90/140 90/140 Coil(s) Qty 1 2 2 2 2 2 Total coil face area per coil 4,2 5,55 5,55 6,4 6,4 6,4 Fan(s) Qty 1 2 2 2 2 2 Air flow m³/h 22.500 30.000 30.000 42.000 42.000 42.000 Speed rpm 900 650 650 860 860 860 Power input each fan W 2.100 930 930 2.100 2.100 2.100 Refrigerant connections Liquid line inch 5/8 5/8 5/8 7/8 7/8 7/8 Suction line inch 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 Dimensions Length mm 2.180 2.180 2.180 2.180 2.180 2.180 Width mm 1.160 1.160 1.160 1.160 1.160 1.160 Height mm 1.986 1.986 1.986 2.286 2.286 2.286 Weight Operating kg 490 560 560 740 850 870 Acoustical data Sound power level db(a) 79 79 79 82 82 82 1 Air: 35 C. Evaporating temperature: +7 C.
Condensing unit
172 Condensing unit Condensing unit SyScroll 85-135 Air RE 94-142 kw Air cooled Scroll 410A Technical feature 5 sizes Cooling capacity from 94,3 to 142,4 kw Fans version: STD (standard) HT (high temperature) HPF (high pressure fans) 2 acoustic versions: - version (Basic Low Noise) S version (Super Low Noise) One refrigerant circuit 2 scroll compressors (1 tandem) Microchannel coils E-Coating coil treatment as standard Accessories and options Coils treatments Unit protection grilles Softstart BMS interface Overload protection for compressors Automatic circuit breaker Fan speed control (standard) Power factor corrector capacitors Sequence phases control (standard) Compressors box (standard) Compressors jackets (standard on Super Low Noise) Operating limit (to be confirmed following selection software issue) SyScroll 85-135 Air RE Ambient Air Air entering temperature (cooling) External static pressure 85 95 105 120 135 Min Max Min Max Min Max Min Max Min Max - C from +10 to +45 S C from -10 to +43 HT-HPF C from -12 to +47 Standard fans Pa 0 High pressure fans (HPF) Pa <120 Minimum capacity step % 50 43 50 44 50 Power supply voltage 1 V 400 V / 3 Ø / 50 Hz (nominal) 1 Voltage 400V +/- 10%.
Condensing unit 173 Technical feature Model 85 95 105 120 135 SyScroll 85-135 Air RE - (STD) Nominal cooling capacity 1 kw 94,3 105,0 116,4 130,5 142,4 Power Input 2 kw 24,8 29,2 34,6 39,8 45,1 Refrigerant In connections inch 1 5/8 1 5/8 2 1/8 2 1/8 2 1/8 Refrigerant Out connections inch 7/8 7/8 1 1/8 1 1/8 1 1/8 SyScroll 85-135 Air RE_ - (S) Nominal cooling capacity 1 kw 90,2 99,8 112,4 125,2 135,7 Power Input 2 kw 26,3 31,3 36,7 42,5 48,4 Refrigerant In connections inch 1 5/8 1 5/8 2 1/8 2 1/8 2 1/8 Refrigerant Out connections inch 7/8 7/8 1 1/8 1 1/8 1 1/8 Weight Shipping kg 625 697 765 817 840 Additional weight HT/HPF Versions kg 20 20 20 20 20 Dimensions Length mm 3.000 3.500 Width mm 1.100 Height mm 2.250 1 Data refers to 7 C evaporating temperature and 35 C condenser air temperature. 2 Input power (only compressors). N.B. For additional technical data regarding compressors, fan motors and noise, please refer to correspondant CO unit. Condensing unit - Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0 FSC -5-10 -15-20 -17-12 -7-2 3 8 13 SST ( C) S Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-17 -12-7 -2 3 8 13 SST ( C) HT-HPF Version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-17 -12-7 -2 3 8 13 SST ( C)
174 Condensing unit Condensing unit AQVC 85-140 94-151 kw Air cooled Scroll 410A Technical features 6 sizes Cooling capacity from 92,1 to 151 kw 2 versions: STD (Standard) SIF (Special Inverter Fans) 2 acoustic versions: BLN (Basic Low Noise) ELN (Extra Low Noise) Two refrigerant circuits 4 Scroll compressors (tandem) E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box as standard Compressors jackets Fan speed control Overload protection for compressors Power factor corrector capacitors Sequence phases control as standard Sofstart Unit protection grilles Operating limit (to be confirmed following selection software issue) AQVC 85-140 85 95 105 115 125 140 Min Max Min Max Min Max Min Max Min Max Min Max Evaporating limit C from +1 to +15 Air temperature BLN C from 0 to +48 from 0 to +48 from 0 to +48 from 0 to +48 from 0 to +48 from 0 to +48 ELN C from -18 to +45 from -18 to +45 from -18 to +45 from -18 to +45 from -18 to +45 from -18 to +45 HT C from 0 to +50 from 0 to +50 from 0 to +50 from 0 to +50 from 0 to +50 from 0 to +50
Condensing unit 175 Technical feature AQVC STD/HSE/HPF 85-140 BLN 85 95 105 115 125 140 Cooling capacity 1 kw 92,1 103,2 113,2 121,8 134,7 151,0 Power input 1 kw 25,3 29,3 32,0 34,9 38,3 43,4 Part load steps % 0-25-50 75-100 0-25-50 75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3/50 Startup type Direct 0-25-50 75-100 0-22-43-72-100 0-25-50 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Quantità 4 Scroll Crankcase heater W 90 90 90 90 90 90 Condenser Qty 2 Frontal surface mm 2.000х1.200 2.000х1.200 2.000х1.200 2.000х1.200 2.600х1.200 2.600х1.200 Connection type To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅝ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Fan Qty 2 Air flow m 3 /h 34.000 34.000 33.200 32.400 44.000 42.800 Speed rpm/min 690 690 690 690 900 900 Power input kw 2,1 2,1 2,1 2,1 3,4 3,4 Weight Shipping kg 971 983 1.013 1.043 1.066 1.142 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 85 85 85 85 89 89 Sound pressure level at 10 m 3 db(a) 53 53 53 53 57 57 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
176 Condensing unit Technical feature AQVC STD/HSE 85-140 ELN 85 95 105 115 125 140 Cooling capacity 1 kw 89 99,4 108,7 116,6 131,6 147,2 Power input 1 kw 26,8 31,3 34,3 37,5 39,8 45,2 Part load steps % 0-25-50 75-100 0-25-50 75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct 0-25-50 75-100 0-22-43-72-100 0-25-50 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Crankcase heater W 90 90 90 90 90 90 Condenser Qty 2 Frontal surface mm 2.000х1.200 2.000х1.200 2.000х1.200 2.000х1.200 2.600х1.200 2.600х1.200 Connection type To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅝ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Fan Qty 2 Air flow m 3 /h 25.200 25.200 24.600 24.000 36.500 35.000 Speed rpm/min 500 500 500 500 690 690 Power input kw 1,8 1,8 1,8 1,8 2,1 2,1 Weight Shipping kg 1.001 1.013 1.043 1.073 1.096 1.172 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 2 db(a) 82 82 82 82 86 86 Sound pressure level at 10 m 3 db(a) 50 50 50 50 54 54 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Condensing unit 177 Technical feature AQVC HT 85-140 85 95 105 115 125 140 Cooling capacity 1 kw 95 106,8 117,7 127 137,2 153,8 Power input 2 kw 23,9 27,4 29,8 32,3 37,1 42,1 Part load steps % 0-25-50 75-100 0-25-50 75-100 0-24-47-74-100 Power supply V/Ph/Hz 400/3+N/50 Startup type Direct 0-25-50 75-100 0-22-43-72-100 0-25-50 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Qty 4 Scroll Crankcase heater W 90 90 90 90 90 90 Condenser Qty 2 Frontal surface mm 2.000х1.200 2.000х1.200 2.000х1.200 2.000х1.200 2.600х1.200 2.600х1.200 Connection type To be brazed Inlet diameter inch ⅝ ⅝ ⅝ ⅝ ⅞ ⅞ Outlet diameter inch 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ 1⅜ Fan Qty 2 Air flow m 3 /h 49.700 49.700 48.950 48.200 52.200 50.700 Speed rpm/min 1.130 1.130 1.130 1.130 1.130 1.130 Power input kw 4,6 4,6 4,6 4,6 4,6 4,6 Weight Shipping kg 971 983 1.013 1.043 1.066 1.142 Dimensions Length mm 2.555 2.555 2.555 2.555 3.155 3.155 Width mm 1.095 1.095 1.095 1.095 1.095 1.095 Height mm 2.185 2.185 2.185 2.185 2.185 2.185 Acoustical data Sound power level 3 db(a) 95 95 95 95 95 95 Sound pressure level at 10 m 4 db(a) 63 63 63 63 63 63 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors). 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
178 Condensing unit Condensing unit SyScroll 140-360 Air EVO RE 165-395 kw Air cooled Scroll 410A Technical feature 9 sizes Cooling capacity from 165 to 394,5 kw Fans versions: STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans) Acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits 4 Scroll compressors E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box as standard Compressors jackets (standard as Super Low Noise) Fan speed control standard Overload protection for compressors Power factor corrector capacitors Sequence phases control as standard Softstarter Unit protection grilles Operating limit (to be confirmed following selection software issue) 140-360 SyScroll 140-360 Air EVO RE Min Evaporating temperature C from +3 to +15 - C from +5 to +48 L C from +0 to +46 Ambient S C from -14 to +44 EC-HT C from -18 to +50 Max
Condensing unit 179 Technical feature Model 140 170 200 230 260 280 300 330 360 SyScroll 140-360 Air EVO RE (STD/EC) Nominal cooling capacity 1 kw 165,0 193,4 216,3 250,3 288,4 312,7 337,2 361,2 394,5 Input power 2 kw 40,6 50,4 54,1 66,1 74,2 81,4 87,5 91,1 103,4 Refrigerant In connections inch 1 5/8 1 5/8 Refrigerant Out connections inch 7/8 7/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 2 1/8 2 1/8 2 1/8 1 1/8 1 1/8 1 1/8 SyScroll 140-360 Air EVO RE L (STD/EC) Nominal cooling capacity 1 kw 165,0 193,4 216,3 250,3 288,4 312,7 337,2 361,2 394,5 Input power 2 kw 42,5 52,8 56,2 69,3 77,6 85,3 91,9 95,3 108,6 Refrigerant In connections inch 1 5/8 1 5/8 1 5/8-2 1/8 1 5/8-2 1/8 1 5/8-2 1/8 1 5/8-2 1/8 2 1/8 2 1/8 2 1/8 Refrigerant Out connections inch 7/8 7/8 7/8-1 1/8 7/8-1 1/8 7/8-1 1/8 7/8-1 1/8 1 1/8 1 1/8 1 1/8 SyScroll 140-360 Air EVO RE S (STD/EC) Nominal cooling capacity 1 kw 149,2 172,1 198,5 225,0 261,4 281,2 305,2 329,9 355,8 Input power 2 kw 45,7 56,7 60,0 75,6 84,2 93,0 100,4 103,5 118,6 Refrigerant In connections inch 1 5/8 1 5/8 1 5/8-2 1/8 1 5/8-2 1/8 1 5/8-2 1/8 1 5/8-2 1/8 2 1/8 2 1/8 2 1/8 Condensing unit Refrigerant Out connections inch 7/8 7/8 7/8-1 1/8 7/8-1 1/8 7/8-1 1/8 7/8-1 1/8 1 1/8 1 1/8 1 1/8 SyScroll 140-360 Air EVO RE HT Nominal cooling capacity 1 kw 166,6 195,6 218,2 252,8 291,2 315,9 340,5 364,4 398,4 Input power 2 kw 40,1 49,8 53,6 65,2 73,3 80,2 86,3 89,9 101,9 Refrigerant In connections inch 1 5/8 1 5/8 Refrigerant Out connections inch 7/8 7/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 2 1/8 2 1/8 2 1/8 1 1/8 1 1/8 1 1/8 Weight Shipping kg 1.107 1.150 1.598 1.695 1.875 1.875 2.364 2.433 2.445 Additional weight EC/HT/HPF versions kg 30 30 50 50 60 60 70 80 80 Dimensions Length mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550 Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors).
180 Condensing unit Condensing unit VLC 604-1204 174-347 kw Air cooled Scroll 410A Technical features 7 sizes Cooling capacity from 174 to 347 kw 4 versions: STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions: BLN (Basic Low Noise) LN (Low Noise) ELN (Extra Low Noise) Two refrigerant circuits Scroll compressors E-Coating coil treatment as standard Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard) Compressors jackets (standard on ELN) Fan speed control (-18 C) Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles
Condensing unit 181 Operating limit (to be confirmed following selection software issue) VLC 604-804 604 704 804 Min Max Min Max Min Max Temperatura di evaporazione C from +3 to +15 BLN C from -5 to +47 1 from -5 to +47 1 from 0 to +46 1 Temperatura aria LN/ELN C from -5 to +45 1 from -5 to +45 1 from 0 to +44 1 HT C from -18 to +49 1 from -18 to +49 1 from -18 to +48 1 1 At high pressure 40,5 bar. VLC 904-1204 904 1004 1104 1204 Min Max Min Max Min Max Min Max Evaporating temperature C from +3 to +15 BLN C from 0 to +46 1 from 0 to +46 1 from 0 to +45 1 from 0 to +45 1 Air temperture LN/ELN C from 0 to +45 1 from 0 to +44 1 from 0 to +42 1 from 0 to +42 1 Condensing unit HT C from -18 to +49 1 from -18 to +48 1 from -18 to +47 1 from -18 to +47 1 1 At high pressure 40,5 bar.
182 Condensing unit Technical feature VLC STD/HPF 604-1204 BLN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 174,0 199,0 224,0 258,0 283,0 315,0 347,0 Power input 1 kw 52,5 63,0 69,0 79,0 83,0 98,0 112,0 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Scroll Qty 4 Condenser Qty 2 Total coil face area per coil m 3 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 900 900 900 900 900 900 900 Air flow m 3 /h 63.000 68.300 68.300 85.000 80.000 75.500 75.500 Power input kw 5,7 5,7 5,7 7,6 7,6 7,6 7,6 Power input * kw 4,0 4,0 4,0 5,3 5,3 5,3 5,3 Available static pressure Pa from 0 to 120 Pa * Refrigerant connection Inlet diameter inch ⅞ ⅞ ⅞ 1⅛ 1⅛ 1⅛ 1⅛ Outlet diameter inch 1⅝ 1⅝ 1⅝ 2⅛ 2⅛ 2⅛ 2⅛ Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Weight Shipping kg 1.300 1.490 1.615 1.700 1.825 1.910 1.920 Additional weights Version HPF kg 10 10 10 15 15 15 15 Acoustical data Sound power level 2 db(a) 93 93 93 94 94 95 95 Sound pressure level at 10 m 3 db(a) 61 61 61 62 62 63 63 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape. * For HPF version with Special Inverter Fans.
Condensing unit 183 Technical feature VLC STD 604-1204 LN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 169,0 194,0 218,0 251,0 272,5 301,0 330,0 Power input 1 kw 55,0 66,0 73,0 83,0 88,0 104,0 121,0 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Scroll Qty 4 Condenser Qty 2 Total coil face per coil m 3 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 700 700 700 700 700 700 700 Air flow m 3 /h 47.300 52.200 52.200 63.700 58.800 54.900 54.900 Power input kw 3,6 3,6 3,6 4,8 4,8 4,8 4,8 Available static pressure Pa 0 Refrigerant connection Liquid diameter inch ⅞ ⅞ ⅞ 1⅛ 1⅛ 1⅛ 1⅛ Gas diameter inch 1⅝ 1⅝ 1⅝ 2⅛ 2⅛ 2⅛ 2⅛ Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Weight Shipping kg 1.300 1.490 1.615 1.700 1.825 1.910 1.920 Acoustical data Sound power level 2 db(a) 87 87 87 88 88 89 89 Sound pressure level at 10 m 3 db(a) 55 55 55 56 56 57 57 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
184 Condensing unit Technical feature VLC STD 604-1204 ELN 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 164,5 188,5 211,0 244,0 264,5 292,0 319,0 Power input 1 kw 57,0 69,0 76,5 86,5 91,5 108,0 127,0 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Scroll Qty 4 Condenser Qty 2 Total coil face per coil m 3 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 550 550 550 550 550 550 550 Air flow m 3 /h 38.500 41.800 41.800 52.000 48.900 46.200 46.200 Power input kw 3 3 3 4 4 4 4 Available static pressure Pa 0 Refrigerant connection Liquid diameter inch ⅞ ⅞ ⅞ 1⅛ 1⅛ 1⅛ 1⅛ Gas diameter inch 1⅝ 1⅝ 1⅝ 2⅛ 2⅛ 2⅛ 2⅛ Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Weight Shipping kg 1.335 1.525 1.650 1.735 1.865 1.950 1.960 Acoustical data Sound power level 2 db(a) 83 83 83 84 84 85 85 Sound pressure level at 10 m 3 db(a) 51 51 51 52 52 53 53 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Condensing unit 185 Technical feature VLC HT 604-1204 604 704 804 904 1004 1104 1204 Cooling capacity 1 kw 176,0 201,0 226,5 261,0 286,5 318,0 353,0 Power input 1 kw 51,5 62,0 68,0 77,5 81,0 95,0 109,0 Part load steps % 28-57- 78-100 20-50- 70-100 25-50- 75-100 28-50- 78-100 25-50- 75-100 23-50- 73-100 25-50- 75-100 Refrigerant HFC 410A Number of refrigerant circuits 2 Compressor Scroll Qty 4 Condenser Qty 2 Total coil face per coil m 3 3,5 4,8 4,8 4,8 4,8 4,8 4,8 Fan Qty 3 3 3 4 4 4 4 Speed rpm/min 1.110 1.110 1.110 1.110 1.110 1.110 1.110 Air flow m 3 /h 71.800 76.200 76.200 95.800 91.200 87.600 87.600 Power input kw 7,2 6,9 6,9 9,6 9,9 10,0 10,0 Available static pressure Pa 0 Refrigerant connection Liquid diameter inch ⅞ ⅞ ⅞ 1⅛ 1⅛ 1⅛ 1⅛ Gas diameter inch 1⅝ 1⅝ 1⅝ 2⅛ 2⅛ 2⅛ 2⅛ Dimensions Length mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300 Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100 Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300 Weight Shipping kg 1.330 1.520 1.645 1.740 1.865 1.950 1960 Acoustical data Sound power level 2 db(a) 99 99 99 100 100 100 100 Sound pressure level at 10 m 3 db(a) 67 67 67 68 68 68 68 Condensing unit 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
186 Condensing unit Condensing unit SyScroll 240-660 Air RE 267-727 kw Air cooled Scroll 410A Technical features 10 sizes Cooling capacity from 267,5 to 726,7 kw 3 versions: STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits 3/4/5/6 Scroll compressors Microchannel coils E-Coating coil treatment as standard Accessories and options Coils treatments Unit protection grilles Softstart BMS interface Overload protection for compressors Automatic circuit breaker Pressostatic fan speed control (standard) Power factor corrector capacitors Sequence phases control (standard) Compressors acoustic box (standard) Compressors jackets (standard )
Condensing unit 187 Operating limit (to be confirmed following selection software issue) SyScroll 240-360 Air RE 240 270 290 320 360 Min Max Min Max Min Max Min Max Min Max - C from +10 to +45 from +10 to +45 from +10 to +45 from +10 to +45 from +10 to +45 Air temp. L C from +7 to +43 from +7 to +43 from +7 to +43 from +7 to +43 from +7 to +43 cooling S C from -14 to +43 from -14 to +43 from -14 to +43 from -14 to +43 from -14 to +43 Ambient temp. HT-HPF C from -18 to +47 from -18 to +47 from -18 to +47 from -18 to +47 from -18 to +47 External Standard fans Pa 0 static High pressure pressure fans Pa <120 Minimum capacity step % 31 33 30 27 23 Power supply voltage 1 V 400 V, 3 Ø, 50 Hz (nominal) 1 Voltage 400V +/- 10%. SyScroll 420-660 Air RE 420 470 540 590 660 Min Max Min Max Min Max Min Max Min Max - C from +10 to +45 from +10 to +45 from +10 to +45 from +10 to +45 from +10 to +45 Air temp. L C from +7 to +43 from +7 to +43 from +7 to +43 from +7 to +43 from +7 to +43 cooling S C from -14 to +43 from -14 to +43 from -14 to +43 from -14 to +43 from -14 to +43 Ambient temp. HT-HPF C from -18 to +47 from -18 to +47 from -18 to +47 from -18 to +47 from -18 to +47 External Standard fans Pa 0 static High pressure pressure fans Pa <120 Minimum capacity step % 31 33 30 27 23 Power supply voltage 1 V 400 V, 3 Ø, 50 Hz (nominal) Condensing unit 1 Voltage 400V +/- 10%. - version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 SFC -10-15 -20-17 -12-7 -2 3 8 13 LWT ( C) L version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 SFC -10-15 -20-17 -12-7 -2 3 8 13 LWT ( C) S version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-17 -12-7 -2 3 8 13 LWT ( C) HT-HPF version OAT ( C) 50 45 40 35 30 25 20 15 10 5 0-5 -10-15 -20-17 -12-7 -2 3 8 13 LWT ( C)
188 Condensing unit Technical feature Model 240 270 290 320 360 SyScroll 240-360 Air RE - Nominal cooling capacity 1 kw 267,5 303,1 330,7 349,9 403,2 Input power 2 kw 76,8 92,8 95,4 103,8 119,0 Refrigerant In connections Refrigerant Out connections inch inch 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 3/8 1 5/8-2 1/8 7/8-1 3/8 2 1/8 1 1/8-1 3/8 SyScroll 240-360 Air RE L Nominal cooling capacity 1 kw 256,7 288,7 316,7 333,9 385,4 Input power 2 kw 80,9 98,4 100,6 109,6 125,8 Refrigerant In connections Refrigerant Out connections inch inch 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 3/8 1 5/8-2 1/8 7/8-1 3/8 2 1/8 1 1/8-1 3/8 SyScroll 240-360 Air RE S Nominal cooling capacity 1 kw 236,4 262,0 262,0 304,4 352,6 Input power 2 kw 89,2 109,2 109,2 120,7 139,2 Refrigerant In connections Refrigerant Out connections inch inch 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 1/8 1 5/8-2 1/8 7/8-1 3/8 2 1/8 1 1/8-1 3/8 Weight Shipping kg 1.670 1.671 1.790 1.802 2.185 Additional weight HT/HPF versions kg 50 50 60 60 70 Dimensions Length mm 3.500 3.500 3.500 3.500 4.550 Width mm 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors).
Condensing unit 189 Technical feature Model 420 470 540 590 660 SyScroll 420-660 Air RE - Nominal cooling capacity 1 kw 466,2 518,8 594,9 650,4 726,7 Input power 2 kw 138,4 148,6 170,6 182,7 204,9 Refrigerant In connections inch 2 1/8 2 1/8-2 5/8 2 1/8-2 5/8 2 5/8 2 5/8 Refrigerant Out connections inch 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 SyScroll 420-660 Air RE L Nominal cooling capacity 1 kw 444,8 495,9 567,7 621,5 693,4 Input power 2 kw 146,1 157,0 180,1 193,1 216,4 Refrigerant In connections inch 2 1/8 2 1/8-2 5/8 2 1/8-2 5/8 2 5/8 2 5/8 Refrigerant Out connections inch 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 SyScroll 420-660 Air RE S Nominal cooling capacity 1 kw 405,5 453,6 517,5 568,1 632,2 Input power 2 kw 161,0 173,5 198,4 213,1 238,3 Refrigerant In connections inch 2 1/8 2 1/8-2 5/8 2 1/8-2 5/8 2 5/8 2 5/8 Condensing unit Refrigerant Out connections inch 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Weight Shipping kg 2.296 2.747 2.860 3.237 3.333 Additional weight HT/HPF versions kg 80 90 100 110 120 Dimensions Length mm 4.550 5.600 5.600 6.650 6.650 Width mm 2.150 2.150 2.150 2.150 2.150 Height mm 2.600 2.600 2.600 2.600 2.600 1 Data refers to 7 C leaving chilled water temperature and 35 C condenser air temperature. 2 Input power (only compressors).
Residential Heat Pump Aquascop HT V2 6-18 kw 407C Aquascop HT split 6-18 kw 407C
Residential Heat Pump 191 Selection guide High Temperature Residential Heat Pump Product Range Capacity COP Flow Rate Acoustic Power Sound Size (LxHxP) mm Aqu@scop HT V2 Aqu@scop HT V2 12.6 Aqu@scop HT V2 14.7 Aqu@scop HT V2 18.9 12.5 kw (A7 C/W35 C) 4.02 1.030 l/h 67dB(A) 1.458 x 516 x 1.308 8.2 kw (A-7 C/W35 C) 2.95 1.030 l/h 67dB(A) 1.458 x 516 x 1.308 15.4 kw (A7 C/W35 C) 4.18 1.370 l/h 1.458 x 516 x 1.308 10.9 kw (A-7 C/W35 C) 3.03 1.370 l/h 67dB(A) 1.458 x 516 x 1.308 18.4 kw (A7 C/W35 C) 4.02 1.580 l/h 67dB(A) 1.458 x 516 x 1.308 12.5 kw (A-7 C/W35 C) 3.08 1.580 l/h 67dB(A) 1.458 x 516 x 1.308 Aqu@scop HT SPLIT Aqu@scop HT SPLIT 12.6 Aqu@scop HT SPLIT 14.7 Aqu@scop HT SPLIT 18.9 12.3 kw (A7 C/W35 C) 3.95 1.030 l/h 8.1 kw (A-7 C/W35 C) 2.90 1.030 l/h 15.15 kw (A7 C/W35 C) 3.84 1.230 l/h 10.7 kw (A-7 C/W35 C) 2.97 1.230 l/h 18.7 kw (A7 C/W35 C) 3.95 1.480 l/h 12.2 kw (A-7 C/W35 C) 3.02 1.480 l/h outdoor unit indoor unit outdoor unit indoor unit outdoor unit indoor unit 65 db(a) 41 db(a) 65 db(a) 41 db(a) 65 db(a) 41 db(a) 1.458 x 516 x 1.308 400 x 260 x 720 1.458 x 516 x 1.308 400 x 260 x 720 400 x 260 x 720 1.458 x 516 x 1.308 Residential Heat Pump
192 Residential Heat Pump Split monobloc-unit high-temperature heat pump Aquascop HT V2 6-18 kw 407C Technical features Ideal for renovations as well as for new construction Water outlet temperature up to 65 C without external backup Ideal for boiler replacement Constant operation at +65 C with -20 C outdoors 6 to 18 kw of heating over 3 models Systemair patented dual-stage cascading compressors A single refrigerant fluid (preloaded up to 20 m) Electronic expansion valve and flow meter Low noise level Three-speed circulator pump Dual-zone management Product Advantages Very high performance, COP up to 4,5 SCOP class A++ Very low noise level No refrigerant links to be made Information screen with eight lines of text in French with diagnosis assistance New antifreeze evaporator, 2 hours without defrosting (no 4-mm fins) Inverter fans Easy maintenance Possibility of installing several heat pumps in cascade (on request) HEATING/ COOLIN G FLOOR heating/ cooling floor LO W TEMPERATURE HEATER lowtemperature radiator - Reversible R407C fluid Outdoor operating limits in heating mode C boiler replacement High temperature up to 65 C boiler backup Product developed and manufactured in France CE standard Operating limit (to be confirmed following selection software issue) bi-zone domestic hot water water programme Patented Water flow setpoint ( C) 70 65 60 55 50 45 DOUBLE STAGE 40 35 30 25 20 15 MONO ÉTAGE SINGLE STAGE Double stage étage - water mini retour return d'eau min. Double stage étage - water maxi départ starting d'eau max. Single Mono stage étage - maxi water départ starting d'eau max. 10-25 -20-15- 10-5 05 10 15 20 25 Outside temperature C [ ] systemair Patented
Residential Heat Pump 193 Accessories and options Wired ambient thermostat - Adjustment of ambient temperature - Daily or weekly programming - Holiday programming, no-frost mode Wireless thermostat with radio communication Sends the measured ambient temperature. 7ACEL1592 7ACEL1593 7ACFH0662 300-litre domestic hot water tank (and 2.5 kw of electrical resistance heaters) optimised with the operation of the Aqu@Scop HT - Three authorisation modes - Holiday mode - Programmable anti-legionella function - Management of the three-way valve / circulator pump couple - 3.1 m 2 exchange surface 7ACFH0663 140-litre buffer tank / mixing tank Necessary when the volume of water in the installation is insufficient. It protects the heat pump against short cycles that can reduce the useful life of the compressors and improves operation during defrosting phases. 7ACFH0543 ON/OFF three-way valve Required for optional production of domestic hot water. Directs the produced hot water either towards the heating circuit or towards the domestic hot water tank. A second three-way valve is recommended for boiler-backup installation. 7ACFH0789 (top outlet) 7ACEL1801 (bottom outlet) Domestic hot water kit Required when replacing existing installations. This kit, made up of a plate exchanger and a circulator pump, enables the production of domestic hot water using existing tanks (electric cumulus). 7ACFH0491 (alone) 7ACFH0490 (kit) Hydraulic kit For connecting to the boiler, available alone or in a complete kit with the three-way valve. Made up of a set of assembled pipes and valves, a set of connectors with spherical-conical seat. 7ACFH0665 On-line electric heater Installation inside the building, offers two power stages (2 and 4 kw, or 6 kw in total). Provides extra heating when the heating demand is greater than the capacity of the heat pump. The Aqu@Scop HT is adjusted to manage the electric heater, or a boiler backup. Residential Heat Pump 7ACFH0666 Decanting pot (sludge pot) Effectively separates the impurities from the heating circuit and collects them in a decanting chamber, where they can be bled off, even while the installation is operational. 7ACTL0472 Shock-absorbing support feet Raise the heat pump by 10cm, allow the evacuation of condensates and defrosting water. Their rubber design provides excellent shock absorption against the transmission of vibrations through solids.
194 Residential Heat Pump Technical feature aquascop ht HT 12-6 HT 14-7 HT 18-9 Dual compressor heating power / water regime 30/35 C kw 12,26 15,15 18,07 COP * 3,95 3,84 3,95 Single compressor heating power / water outlet 30/35 C kw 6,3 8,35 9,71 Outdoor air COP * 4,12 4,35 4,52 regime 7 C Single compressor heating power / water outlet 45 C kw 5,74 7,77 9,27 COP * 3,09 3,31 3,47 Dual compressor heating power / water outlet 55 C kw 5,25 7,08 8,58 COP * 2,28 2,48 2,62 Outdoor air Single compressor heating power / water outlet 35 C kw 10,31 13 15,32 regime 2 C COP * 3,45 3,4 3,49 Single compressor heating power / water outlet 35 C kw 8,05 10,68 12,21 COP * 2,9 2,97 3,02 Outdoor air Dual compressor heating power / water outlet 55 C kw 8,40 10,71 12,44 regime -7 C COP * 2,25 2,31 2,35 Dual compressor heating power / water outlet 65 C kw 8,33 10,69 12,01 COP * 1,87 2,02 2,03 Dual compressor heating power / water outlet 35 C kw 7,79 10,24 11,71 Outdoor air COP * 2,80 2,86 2,9 regime -15 C Dual compressor heating power / water outlet 65 C kw 8 10,27 11,5 COP * 1,81 1,96 1,96 Sound power at 5 m in free field db(a) Sound power db(a) 65 65 65 Compressor type (R407C) 2 scroll compressors in cascade Dimensions (WxDxH) mm 47 47 47 Outdoor unit Weight kg 184 209 213 Refrigerant connections (gas/liquid) (0 to 25 metres) 5/8-3/8 Refrigerant connections (gas/liquid) (0 to 45 metres) 3/4-1/2 Maximum length m 45 45 45 Maximum height difference m 15 15 15 Outdoor temperature operating limits ** C -20-20 -20 Power supply Power cable mm 2 3x6 3x6 N/D 1~230V-50Hz Protection rating A 32 32 N/D Power supply Power cable mm 2 5x2,5 5x2,5 5x2,5 3~400V-50Hz Protection rating A 16 16 20 Sound power at 5 m in free field db(a) Sound power db(a) 41 41 41 Dimensions (WxDxH) mm 400x260x720 Weight kg 28 28 30 Indoor unit Finish Brushed aluminium Exchanger type Plates Water intake/outlet connections inches 1 Female Nominal water flow m 3 /h 1,03 1,23 1,48 Water outlet temperatures (mini/maxi) C 25 C/65 C Available hydraulic pressure kpa 57 49 56 Power supply Power cable mm 2 3x1,5 3x1,5 3x1,5 1~230V-50Hz Protection rating A 4 4 4 * COP values with defrosting. ** According to application conditions.
Residential Heat Pump
196 Residential Heat Pump Split high temperature heat pump Aquascop HT split 6-18 kw 407C Technical features Ideal for renovations as well as for new construction Water outlet temperature up to 65 C without external backup Ideal for boiler replacement Constant operation at +65 C with -20 C outdoors 6 to 18 kw of heating over 3 models Systemair patented dual-stage cascading compressors A single refrigerant fluid (preloaded up to 20 m) Electronic expansion valve and flow meter Low noise level Three-speed circulator pump Dual-zone management Product Advantages Very high performance, COP up to 4.5 Aesthetics and aluminium finish Very low noise level Compact wall unit (700x400x260) Weight of 30 kg only for the indoor unit, can be installed by one person working alone Fluid connections on the bottom surface Cover removable by a quarter turn for immediate access Information screen with eight lines of text in French with diagnosis assistance New antifreeze evaporator, 2 hours without defrosting (no 4-mm fins) Inverter fans No risk of frost for the water, and no need to add glycol to the installation Easy maintenance Possibility of installing several heat pumps in cascade Reversible R407C fluid Outdoor operating limits in heating mode HEATING/ COOLIN G FLOOR heating/ cooling floor bi-zone LO W TEMPERATURE HEATER lowtemperature radiator domestic hot water - C boiler replacement water programme High temperature up to 65 C boiler backup Patented Product developed and manufactured in France CE standard Advantages of the Systemair high-temperature [ ] systemair Patented Each compressor works with a low compression rate, ensuring longer service life and reduced electricity consumption. Heating power of the heat pump maintained even at low temperatures. Remarkable adaptability of power supplied / requirements thanks to the option of using the compressors separately. Optimised domestic hot water production, staging of the compressors adapted according to the exchange capacity of the tank, while taking into account the outside temperature.
Residential Heat Pump 197 Accessories and options Wired ambient thermostat - Adjustment of ambient temperature - Daily or weekly programming - Holiday programming, no-frost mode Wireless thermostat with radio communication Sends the measured ambient temperature. 7ACEL1592 7ACEL1593 7ACFH0662 300-litre domestic hot water tank (and 2.5 kw of electrical resistance heaters) optimised with the operation of the Aqu@Scop HT - Three authorisation modes - Holiday mode - Programmable anti-legionella function - Management of the three-way valve / circulator pump couple - 3.1 m 2 exchange surface 7ACFH0663 140-litre buffer tank / mixing tank Necessary when the volume of water in the installation is insufficient. It protects the heat pump against short cycles that can reduce the useful life of the compressors and improves operation during defrosting phases. 7ACFH0543 ON/OFF three-way valve Required for optional production of domestic hot water. Directs the produced hot water either towards the heating circuit or towards the domestic hot water tank. A second three-way valve is recommended for boiler-backup installation. 7ACFH0789 (top outlet) 7ACEL1801 (bottom outlet) Domestic hot water kit Required when replacing existing installations. This kit, made up of a plate exchanger and a circulator pump, enables the production of domestic hot water using existing tanks (electric cumulus). 7ACFH0491 (alone) 7ACFH0490 (kit) Hydraulic kit For connecting to the boiler, available alone or in a complete kit with the three-way valve. Made up of a set of assembled pipes and valves, a set of connectors with spherical-conical seat. 7ACFH0665 On-line electric heater Installation inside the building, offers two power stages (2 and 4 kw, or 6 kw in total). Provides extra heating when the heating demand is greater than the capacity of the heat pump. The Aqu@Scop HT is adjusted to manage the electric heater, or a boiler backup. Residential Heat Pump 7ACFH0666 Decanting pot (sludge pot) Effectively separates the impurities from the heating circuit and collects them in a decanting chamber, where they can be bled off, even while the installation is operational. 7ACTL0472 Shock-absorbing support feet Raise the heat pump by 10cm, allow the evacuation of condensates and defrosting water. Their rubber design provides excellent shock absorption against the transmission of vibrations through solids.
198 Residential Heat Pump Technical feature AQUASCOP HT SPLIT HT 12-6 HT 14-7 HT 18-9 Dual compressor heating power / water regime 30/35 C kw 12,26 15,15 18,07 COP * 3,95 3,84 3,95 Single compressor heating power / water outlet 30/35 C kw 6,3 8,35 9,71 Outdoor air COP * 4,12 4,35 4,52 regime 7 C Single compressor heating power / water outlet 45 C kw 5,74 7,77 9,27 COP * 3,09 3,31 3,47 Dual compressor heating power / water outlet 55 C kw 5,25 7,08 8,58 COP * 2,28 2,48 2,62 Outdoor air Single compressor heating power / water outlet 35 C kw 10,31 13 15,32 regime 2 C COP * 3,45 3,4 3,49 Single compressor heating power / water outlet 35 C kw 8,05 10,68 12,21 COP * 2,9 2,97 3,02 Outdoor air Dual compressor heating power / water outlet 55 C kw 8,40 10,71 12,44 regime -7 C COP * 2,25 2,31 2,35 Dual compressor heating power / water outlet 65 C kw 8,33 10,69 12,01 COP * 1,87 2,02 2,03 Dual compressor heating power / water outlet 35 C kw 7,79 10,24 11,71 Outdoor air COP * 2,80 2,86 2,9 regime -15 C Dual compressor heating power / water outlet 65 C kw 8 10,27 11,5 COP * 1,81 1,96 1,96 Sound power at 5 m in free field db(a) Sound power db(a) 65 65 65 Compressor type (R407C) 2 scroll compressors in cascade Dimensions (WxDxH) mm 47 47 47 Outdoor unit Weight kg 184 209 213 Refrigerant connections (gas/liquid) (0 to 25 metres) 5/8-3/8 Refrigerant connections (gas/liquid) (0 to 45 metres) 3/4-1/2 Maximum length m 45 45 45 Maximum height difference m 15 15 15 Outdoor temperature operating limits ** C -20-20 -20 Power supply Power cable mm 2 3x6 3x6 N/D 1~230V-50Hz Protection rating A 32 32 N/D Power supply Power cable mm 2 5x2,5 5x2,5 5x2,5 3~400V-50Hz Protection rating A 16 16 20 Sound power at 5 m in free field db(a) Sound power db(a) 41 41 41 Dimensions (WxDxH) mm 400x260x720 Weight kg 28 28 30 Indoor unit Finish Brushed aluminium Exchanger type Plates Water intake/outlet connections inches 1 Female Nominal water flow m 3 /h 1,03 1,23 1,48 Water outlet temperatures (mini/maxi) C 25 C/65 C Available hydraulic pressure kpa 57 49 56 Power supply Power cable mm 2 3x1,5 3x1,5 3x1,5 1~230V-50Hz Protection rating A 4 4 4 * COP values with defrosting. ** According to application conditions.
Residential Heat Pump
Water Terminals SysCoil 2 NEW 0.48-10.0 kw 0.79-12.7 kw Motor EC Hawair 4-4 kw 5.2-33.9 kw KOG LN (Cassette) 1.6-9.3 kw 2.1-11.7 kw Motor EC Ductys 0.6-6.8 kw 0.7-8.8 kw Motor EC KOG LN (cassette) 1.6-9.3 kw 2.1-11.7 kw Motor EC VH 1-9 kw 1.2-11.3 kw KCO2 1-9 kw 1.2-11.3 kw Motor EC Selection guide water terminals units Fan Coil units SysCoil 2 Product Range Capacity Acoustic Flow rate Pressure Fan Size (LxHxP) SC10 1.8 kw NR 24 at MS 108-417 m³/h 0-30 Pa EC 766 x 477 x 225 SC20 2.1 kw NR 26 at MS 98-413 m³/h 0-30 Pa EC 766 x 477 x 225 SC30 2.4 kw NR 28 at MS 185-570m³/h 0-30 Pa EC 951 x 477 x 225 SC40 3.7 kw NR 20 at MS 163-667 m³/h 0-30 Pa EC 1.136 x 477 x 225 NR 28 at MS 203-816 m³/h 0-40 Pa EC 1.321 x 477 x 225 NR 30 at MS 245-912 m³/h 0-40 Pa EC 1.506 x 477 x 225 NR 28 at MS 416-1.028 m³/h 0-40 Pa EC 1.321 x 577 x 225 NR 31 at MS 685-1.398 m³/h 0-40 Pa EC 1.508 x 578 x 225 SC50 SC60 SC70 AQUAFAN TTE SC80 20 TTE 40 TTE 60 TTE 4.4 kw 5.4 kw 6.5 kw 9.1 kw 2.3 kw 4.5 kw 7.2 kw NR 29 at MS 137-358 m³/h 0 Pa 768 x 478 x 231 NR 30 at MS 312-672 m³/h 0 Pa 1.138 x 478 x 231 0 Pa 1.508 x 478 x 231 NR 42 at MS 492-1.018 m³/h
Water Terminals 201 Selection guide water terminals units Water cassette Product Range KOG 09 LN KOG LN KOG 12 LN KOG 18 LN KOG 30 LN IRYS 2.3 kw 3.5 kw 4.6 kw 6.4 kw KOG 45 LN KCO2 60 KCO 2 Capacity KCO2 90 KCO2 120 10.2 kw 1.6 kw 3.2 kw 4.1 kw Acoustic Flow rate Pressure Fan Size (LxHxP) NR 27 at MS 330-720 m³/h 0 Pa EC 625 x 625 x 287 NR 27 at MS 330-720 m³/h 0 Pa EC 625 x 625 x 287 NR 28 at MS 290-830 m³/h 0 Pa EC 625 x 625 x 287 NR 37 at MS 1.100-1.550 m³/h 0 Pa EC 1.225 x 625 x 287 NR 40 at MS 1.000-1.630 m³/h 0 Pa EC 1.225 x 625 x 287 NR 28 at MS 140-305 m³/h 0 Pa EC 492 x 492 x 309 NR 27 at MS 200-560 m³/h 0 Pa EC 970 x 492 x 309 NR 30 at MS 290-680 m³/h 0 Pa EC 1.192 x 492 x 309 Acoustic Flow rate Pressure Fan Size (LxHxP) Highwall HAWAIR Product Range Capacity 2.2 kw NR 27 at MS 320-450 m³/h 0 Pa - 845 x 275 x 180 HAWAIR 09 2.9 kw NR 29 at MS 400-600 m³/h 0 Pa - 845 x 275 x 180 HAWAIR 18 3.6 kw NR 35 at MS 550-750 m³/h 0 Pa - 940 x 298 x 200 NR 41 at MS 650-900 m³/h 0 Pa - 940 x 298 x 200 Capacity Acoustic Flow rate Pressure Fan Size (LxHxP) DT 1000 1.4 kw NR 30 at MS 90-370 m³/h 0-80 Pa EC 581 x 540 x 223 DT 1500 2 kw NR 30 at MS 270-505 m³/h 0-80 Pa EC 581 x 640 x 223 DT 2000 2.5 kw NR 31 at MS 370-600 m³/h 0-80 Pa EC 581 x 740 x 223 NR 31 at MS 440-640 m³/h 0-80 Pa EC 581 x 840 x 223 HAWAIR 22 4.7 kw Ducted DUCTYS Product Range DT 2500 3.3 kw DT 4000 6 kw NR 35 at MS 316-1190 m³/h 0-80 Pa EC 581 x 1.140 x 223 VH07 6.2 kw NR 34 at MS 648-1251 m³/h 0-150 Pa EC 698 x 1.200 x 250 NR 40 at MS 671-3176 m³/h 0-150 Pa EC 798 x 1.380 x 375 NR 40 at MS 671-3176 m³/h 0-150 Pa EC 798 x 1.380 x 375 NR 40 at MS 671-3176 m³/h 0-150 Pa EC 798 x 1.380 x 375 NR 44 at MS 1938-3882 m³/h 0-150 Pa EC 798 x 1.500 x 450 NR 44 at MS 1938-3882 m³/h 0-150 Pa EC 798 x 1.500 x 450 VH15 18.9 kw VH VH18 14.8 kw VH21 VH24 VH27 21.9 kw 23.9 kw 28.4 kw Water Terminals HAWAIR 07
202 Water Terminals A Large Range... with lowercase Innovation and easy installation Fin coils for efficient and hygienic solution. Cost-optimized 3-speed setting for EC fan. Control ready-to-install. Wide range of control.
Water Terminals 203 A large range of terminal units dedicated to energy saving and comfort: Low consumption solution with: High efficiency fan motor available on fan coil, ducted fan coil and cassette range High level of energy performance with mainly Energy class A or B Same thermal performance as with AC fan motor Silence Optimized fan speed staging for new low noise versions Reinforced acoustical insulation Profiled air diffuser Factory facilities dedicated to flexibility and quality Many factory-mounted options or accessories: Control Valve Air diffuser Condensate drain pump Products fully customized to satisfy your requirements: Choice of service side for hydraulic and electric connection Version with or without cabinet On-board control 100% units are tested electrically and acoustically. Water Terminals All Terminals Units are according to Eurovent standard.
204 Water Terminals Fan coils units Cooling and heating SysCoil 2 VC/HC 0.49-9.14 kw 0.81-12.58 kw HOTEL OFFICES Technical features Cooling Capacity from 0.49 to 9.14 kw Heating Capacity from 0.81 to 12.58 kw 8 sizes Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration VC Vertical console units with cabinet HC Ceiling exposed units with cabinet Product Advantages Ease of installation Harmonuous and aesthetic RAL 9003 painted cabinet design Streamlined design and elaborate finish enabling harmonious integration 5-speed AC fan motor Very low operating acoustical levels Airflow rate between 89 and 1.397 m³/h Extended monobloc condensate drain pan Main accessories and options Selection of 3 speed Electrical heater On-board electronic control or terminal block for wallmounted control Modbus communication interface board 2-way or 3-way ON/OFF valve Condensate drain pump G3 filter Fuse holder Selection of service side Large choice of controls : Electro-mechanic, electronic, on-board or wall-mounted Suspension kit Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 5 bars 5 C/15% RH 32 C/70% RH
Water Terminals 205 Technical feature SysCoil 2 VC/HC SC10 SC20 SC30 SC40 SC50 SC60 SC70 SC80 Capacities - 2 Pipe V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 Cooling 1 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating Heating 2 capacity Capacities - 4 Pipe Cooling 1 Heating 3 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating capacity Water flow Water pressure drop Sound Levels - 2 Pipes W W l/h kpa W W W l/h 590 / 930 / 1.290 470/ 750 / 1.050 102 / 161 / 222 2.9 / 6.6 / 11.9 810 / 1.300 / 1.810 490 / 800 / 1.110 390 / 640 / 900 85 / 137 / 192 700 / 1.100 / 1.490 520 / 830 / 1.170 120 / 189 / 257 1.7 / 3.3 / 5.3 860 / 1.380 / 1.950 580 / 950 / 1.310 430 / 720 / 1.020 99 / 163 / 226 kpa 2.1 / 4.9 / 9.1 1.3 / 2.6 / 4.3 W l/h 830 / 960 / 1.240 / 1.650 1.380 / 1.730 71 / 107 / 142 kpa 1/ 1.9 / 3.3 82 / 118 / 149 1.1 / 2.1 / 3.3 1.210 / 1.950 / 2.400 1100 / 1.710 / 2.100 208 / 335 / 413 4.4 / 9.9 / 14.3 1.350 / 2.360 / 2.970 1.080 / 1.760 / 2.130 990 / 1.550 / 1.840 186 / 303 / 368 3.7 / 8.3 / 11.7 1.560 / 2.220 / 2.550 135 / 192 / 220 3.8/ 6.6 / 8.2 970 / 2.140 /2.810 670 / 1.620 / 2.070 167 / 368 / 484 3.9 / 14 / 22.5 1.370 / 2.710 / 3.670 1.620 /3.070 / 4.090 1.260 / 2.160 / 3.000 279 / 528 / 705 4.1 / 13 / 22.4 2.050 / 3.940 / 5.400 2.630 / 4.180 / 5.460 1.790 / 2.960 / 4.030 452 / 721 / 941 10.4 / 25.2 / 42.2 2.360 / 3.970 / 5.270 860 / 1.470 / 2.410 / 1.900 / 2.520 2.790 / 3.690 3.830 / 4.980 590 / 1.150 / 1.640 / 1.440 / 1.880 1.970 / 2.690 2.700 / 3.660 148 / 327 / 435 3.3 / 11.5 / 18.7 1.580 / 2.660 / 3.340 136 / 229 / 288 4.1 / 10.1 / 15.3 254 / 480 / 635 3.5 / 10.9 / 18.4 2.370 / 3.760 / 4.810 204 / 324 / 414 7.5 / 16.8 / 26.1 414 / 660 / 857 8.8 / 21.3 / 35.2 2.340 / 3.580 / 4.530 201 / 308 / 391 9.1 / 18.5 / 27.9 3.100 / 5.840 / 6.620 2.170 / 4.280 / 5.030 533 / 1006 / 1140 4 / 13.9 / 17.9 4.140 / 7.370 / 8.720 2.840 / 5.260 / 5.980 1.980 / 3.840 / 4.490 490 / 906 / 1030 3.4 / 11.3 / 14.6 4.240 / 5.900 / 7.050 365 / 508 / 607 23.1 / 41.1 / 56.5 4.710 / 6.650 / 9.140 3.490 / 4.930 / 6.990 811 / 1146 / 1575 12.3 / 22.6 / 40.3 6.520 / 9.250 / 12.580 4.560 / 6.490 / 9.030 3.360 / 4.790 / 6.880 785 / 1.117 / 1.555 11.6 / 21.7 / 39.6 6.660 / 9.440 / 11.790 573 / 813 / 1.016 17 / 31.9 / 48.1 Sound power level db(a) 33 / 41 / 47 32 / 44 / 51 40 / 53 / 59 29 / 46 / 53 36 / 48 / 57 40 / 52 / 58 46 / 59 / 63 52 / 57 / 66 Sound pressure level 4 db(a) 19 / 24 / 31 16 / 28 / 35 24 / 37 / 43 14 / 30 / 37 20 / 33 / 41 24 / 36 / 42 30 / 43 / 47 34 / 41 / 49 NR 4 db(a) 10 / 15 / 22 5 / 20 / 26 14 / 28 / 34 5 / 22 / 27 9 / 22 / 31 14 / 28 / 34 21 / 33 / 36 26 / 34 / 48 Sound Levels - 4 Pipes Sound power level db(a) 33 / 41 / 47 32 / 44 / 51 40 / 53 / 59 29 / 46 / 53 36 / 48 / 57 40 / 52 / 58 46 / 59 / 63 52 / 57 / 66 Sound pressure level 4 db(a) 19 / 24 / 31 16 / 28 / 35 24 / 37 / 43 14 / 30 / 37 20 / 33 / 41 24 / 36 / 42 30 / 43 / 47 34 / 41 / 49 NR 4 db(a) 10 / 15 / 22 5 / 20 / 26 14 / 28 / 34 5 / 22 / 27 9 / 22 / 31 14 / 28 / 34 21 / 33 / 36 26 / 34 / 48 Fans Number 1 1 1 2 2 2 2 3 Airflow - 2 Pipes Airflow - 4 Pipes m³/h m³/h 111 / 190 / 283 95 / 168 / 253 105 / 179 / 265 89 / 161 / 241 229 / 388 / 483 214 / 366 / 450 172 / 356 / 493 162 / 333 / 461 253 / 486 / 716 242 / 466 / 671 350 / 640 / 933 334 / 614 / 885 480 / 893 / 1064 470 / 859 / 1012 660 / 936 / 1397 634 / 905 / 1370 Electrical Data Power supply V/Ph/ Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz Fan consumption - 2 pipes W 14 / 24 / 36 14 / 23 / 35 24 / 50 / 81 18 / 39 / 59 33 / 57 / 80 39 / 76 / 111 60 / 114 / 161 90 / 112 / 188 Fan consumption - 4 pipes W 14 / 24 / 36 14 / 23 / 34 24 / 50 / 80 18 / 39 / 58 33 / 56 / 78 39 / 75 / 110 60 / 113 / 159 90 / 112 / 188 Electrical heater (max) W 500 500 5.00/1.000 1.250/2.500 1.250/2.500 1.250/2.500 1.000/2.000 1.500/3.000 Water Connections Gas female threaded Cooling coil inches 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Heating coil inches 1/2 Dimensions LxWxH SVC LxWxH SHC mm mm 766 x 225 x 477 766 x 477 x 225 766 x 225 x 477 766 x 477 x 225 951 x 225 x 477 951 x 477 x 225 1.136 x 225 x 477 1.136 x 477 x 225 1.321 x 225 x 477 1.321 x 477 x 225 1.506 x 225 x 477 1.506 x 477 x 225 1.321 x 225 x 577 1.321 x 577 x 225 1.508 x 225 x 578 1.508 x 578 x 225 Weight Unit weight SVC kg 18 18 21.5 27 30 35 35 50 Unit weight SHC kg 19 19 22.5 29 32 37 37 52 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 According to Eurovent standard. Air: 20 C, Water in: 70 C/60 C. 4 Informative data, considering a sound attenuation of the room and installation of 16dBA.
206 Water Terminals Fan coils units Cooling and heating SysCoil 2 VC/HC EC 0.48-10.0 kw EC Motor 0.79-12.7 kw HOTEL OFFICES Technical features Cooling Capacity from 0.48 to 10.0 kw Heating Capacity from 0.79 to 12.7 kw 8 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration VC Vertical console units with cabinet HC Ceiling exposed units with cabinet Product Advantages Ease of installation Harmonuous and aesthetic RAL9003 painted cabinet design Streamlined design and elaborate finish enabling harmonious integration Very low operating acoustical levels Airflow rate between 84 and 1.548 m³/h Extended monobloc condensate drain pan Main accessories and options EC motor Selection of 3 speed Electrical heater On-board electronic control or terminal block for wall-mounted control Modbus communication interface board 2-way or 3-way ON/OFF valve Condensate drain pump G3 filter Fuse holder Selection of service side Large choice of controls : Electro-mechanic, electronic, onboard or wall-mounted Suspension kit Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 5 bars 5 C/15% RH 32 C/70% RH
Water Terminals 207 Technical feature SysCoil 2 VC/HC EC SC10 SC20 SC30 SC40 SC50 SC60 SC70 SC80 Capacities - 2 Pipe V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 Cooling 1 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating Heating 2 capacity Capacities - 4 Pipe Cooling 1 Heating 3 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating capacity Water flow Water pressure drop Sound levels - 2 Pipes W W l/h kpa W W W l/h 580 / 1.080 / 1.790 460 / 870 / 1.490 100 / 186 / 309 2.7 / 8.5 / 22.1 790 / 1.510 / 2.570 480 / 920 / 1.560 370 / 740 / 1.280 82 / 159 / 268 660 / 1.350 / 2.160 490 / 1.050 / 1.770 114 / 232 / 373 1.6 / 4.5 / 9.6 810 / 1.750 / 2.940 550 / 1.130 / 1.930 410 / 870 / 1.550 95 / 195 / 333 kpa 1.9 / 6.4 / 17 1.2 / 3.4 / 8 W l/h 810 / 1.410 / 2.220 69 / 121 / 191 930 / 1.560 / 2.280 80 / 135 / 197 kpa 1 / 2.4 / 6 1 / 2.7 / 5.7 670 / 1.610 / 2.430 560 / 1.360 / 2.040 115 / 277 / 418 1.7 / 7.1 / 14.6 980 / 2.150 / 3.310 500 / 1.370 / 2.130 410 / 1.150 / 1.790 87 / 235 / 366 1.1 / 5.4 / 11.5 1.680 / 2.420 / 2.890 145 / 209 / 249 4.2/ 7.6 / 10.1 1.270 / 2.660 / 3.720 940 / 1.760 / 2.670 218 / 457 / 642 5.9 / 20.4 / 37.4 1.310 / 2.850 / 4.900 1.090 / 2.320 / 3.370 830 / 1.560 / 2.390 189 / 400 / 580 4.7 / 16.1 / 31 2.030 / 3.440 / 4.470 175 / 296 / 385 6.3 / 16.1 / 28.5 1.260 / 3.810 / 4.400 1.060 / 2.740 / 3.350 217 / 657 / 759 2.6 / 19.6 / 25.8 1.580 / 4.910 / 5.800 1.090 / 3.300 / 3.970 930 / 2.390 / 2.970 188 / 568 / 685 2.1 / 14.9 / 21.2 2.570 / 3.980 / 4.980 221 / 342 / 429 8.6 / 18.5 / 27.9 2.060 / 4.610 / 5.370 1.370 / 3.320 / 3.960 355 / 794 / 925 6.6 / 30.4 / 40.8 1.780 / 4.420 / 5.170 1.750 / 4.080 / 4.810 1.150 / 2.990 / 3.520 301 / 703 / 829 4.9 / 24.1 / 33 1.770 / 3.790 / 4.400 152 / 326 / 379 5.8 / 20.3 / 26.4 2.590 / 5.520 / 6.510 1.810 / 3.970 / 4.870 446 / 951 / 1.122 2.8 / 12.5 / 17.3 4.880 / 6.590 / 9.150 3.620 / 4.890 / 6.990 841 / 1.135 / 1.575 13.1 / 22.2 / 40.3 6.740 / 3.640 / 6.870 / 8.460 9.170 / 12.580 2.190 / 4.740 / 4.730 / 5.710 6.340 / 10.000 1.530 / 3.400 / 4.220 377 / 816 / 983 2 / 9.2 / 13.3 4.040 / 5.640 / 6.830 348 / 486 / 588 21.3 / 38 / 53.3 3.500 / 4.680 / 7.690 817 / 1092 / 1722 12.5 / 20.8 / 47.8 6.920 / 9.220 / 12.700 596 / 794 / 1093 18.2 / 30.5 / 55.2 Sound power level db(a) 40 / 49 / 61 36 / 50 / 62 33 / 54 / 62 31 / 45 / 57 34 / 52 / 58 34 / 55 / 59 40 / 54 / 59 53 / 58 / 66 Sound pressure level 4 db(a) 25 / 33 / 45 20 / 34 / 46 17 / 37 / 46 15 / 29 / 41 19 / 36 / 42 18 / 39 / 43 24 / 38 / 43 33 / 39 / 49 NR 4 db(a) 16 / 24 / 35 10 / 26 / 35 10 / 28 / 37 5 / 20 / 32 8 / 28 / 33 6 / 30 / 33 14 / 28 / 33 23 / 31 / 42 Sound levels - 4 Pipes Sound power level db(a) 40 / 49 / 61 36 / 50 / 62 33 / 54 / 62 31 / 45 / 57 34 / 52 / 58 30 / 55 / 59 40 / 54 / 59 53 / 58 / 66 Sound pressure level 4 db(a) 25 / 33 / 45 20 / 34 / 46 17 / 37 / 46 15 / 29 / 41 19 / 36 / 42 15 / 39 / 43 24 / 38 / 43 33 / 39 / 49 NR 4 db(a) 16 / 24 / 35 10 / 26 / 35 10 / 28 / 37 5 / 20 / 32 8 / 28 / 33 6 / 30 / 33 14 / 28 / 33 23 / 31 / 42 Fans Number 1 1 1 2 2 2 2 3 Airflow - 2Pipes m³/h Airflow - 2Pipes m³/h 108 / 228 / 417 98 / 234 / 413 185 / 384 / 570 91 / 199 / 379 84 /200 / 380 155 / 346 / 526 163 / 385 / 667 144 / 349 / 615 203 / 645 / 816 185 / 587 / 754 245 / 737 / 912 205 / 668 / 845 417 / 827 / 1028 390 / 777 / 969 685 / 927 / 1398 660 / 884 / 1548 Electrical Data Power supply V/Ph/ Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz Fan consumption-2pipes W 8 / 14 / 41 8 / 15 / 41 6 / 19 / 46 2 / 13 / 43 2 / 24 / 46 2 / 30 / 54 12 / 45 / 77 23 / 42 / 108 Fan consumption-4pipes W 8 / 14 / 39 8 / 15 / 40 6 / 18 / 45 2 / 12 / 41 2 / 23 / 44 2 / 28 / 52 12 / 44 / 74 22 / 41 / 116 Set voltage V 2 / 5 / 10 2 / 5 / 10 2 / 6 / 10 2 / 5 / 10 2 / 7 / 10 2 / 7 / 10 4 / 8 / 10 3 / 4.1 / 6 Electrical heater (max) W 500 500 500/1.000 1.250/2.500 1.250/2.500 1.250/2.500 1.000/2.000 1.500/3.000 Water Connections Gas female threaded Cooling coil inches 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Heating coil inches 1/2 Dimensions LxWxH SVC mm 766 x 766 x 951 x 1.136 x 1.321 x 1.506 x 1.321 x 1.508 x 225 x 477 225 x 477 225 x 477 225 x 477 225 x 477 225 x 477 225 x 577 225 x 578 LxWxH SHC mm 766 x 766 x 951 x 1.136 x 1.321 x 1.506 x 1.321 x 1.508 x 477 x 225 477 x 225 477 x 225 477 x 225 477 x 225 477 x 225 577 x 225 578 x 225 Weight Unit weight SVC kg 18 18 21.5 27 30 35 35 50 Unit weight SHC kg 19 19 22.5 29 32 37 37 52 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 According to Eurovent standard. Air: 20 C, Water in: 70 C/60 C. 4 Informative data, considering a sound attenuation of the room and installation of 16dBA.
208 Water Terminals Fan coils units Cooling and heating SysCoil 2 VN/HN 0.49-9.14 kw 0.81-12.58 kw HOTEL OFFICES Technical features Cooling Capacity from 0.49 to 9.14 kw Heating Capacity from 0.81 to 12.58 kw 8 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration VN Vertical concealed units without cabinet HN Ceiling concealed units without cabinet Product Advantages Ease of installation Streamlined design and elaborate finish enabling harmonious integration 5-speed AC fan motor Very low operating acoustical levels Airflow rate between 89 and 1.397 m³/h Extended monobloc condensate drain pan Main accessories and options EC motor Selection of 3 speed Electrical heater On-board electronic control or terminal block for wall-mounted control Modbus communication interface board 2-way or 3-way ON/OFF valve Condensate drain pump G3 filter Fuse holder Selection of service side Large choice of controls : Electro-mechanic, electronic, onboard or wall-mounted Suspension kit Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 5 bars 5 C/15% RH 32 C/70% RH
Water Terminals 209 Technical feature SysCoil 2 VN/HN STD SC10 SC20 SC30 SC40 SC50 SC60 SC70 SC80 Capacities - 2 Pipe V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 Cooling 1 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating Heating 2 capacity Capacities - 4 Pipe Cooling 1 Heating 3 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating capacity Water flow Water pressure drop Sound Levels - 2 Pipes W W l/h kpa W W W l/h 590 / 930 / 1.290 470 / 750 / 1.050 102 / 161 / 222 2.9 / 6.6 / 11.9 810 / 1.300 / 1.810 490 / 800 / 1.110 390 / 640 / 900 85 / 137 / 192 700 / 1.100 / 1.490 520 / 830 / 1.170 120 / 189 / 257 1.7 / 3.3 / 5.3 860 / 1.390 / 1.950 580 / 950 / 1.310 430 / 720 / 1.020 99 / 163 / 226 kpa 2.1 / 4.9 / 9.1 1.3 / 2.6 / 4.3 W l/h 830 / 1.240 / 1.650 71 / 107 / 142 kpa 1 / 1.9 / 3.3 960 / 1.380 / 1.730 82 / 118 / 149 1.1 / 2.1 / 3.3 1.210 / 1.950 / 2.400 1.100 / 1.710 / 2.100 208 / 335 / 413 4.4 / 9.9 / 14.3 1.350 / 2.360 / 2.970 1.080 / 1.760 / 2.130 990 / 1.550 / 1.870 186 / 303 / 368 3.7 / 8.3 / 11.7 1.560 / 2.220 / 2.550 135 / 192 / 220 3.8/ 6.6 / 8.2 970 / 2.140 / 2.810 670 / 1.620 / 2.070 167 / 368 / 484 3.9 / 14 / 22.5 1.370 / 2.710 / 3.670 860 / 1.900 / 2.520 590 / 1.440 / 1.880 148 / 327 / 435 3.3 / 11.5 / 18.7 1.580 / 2.660 / 3.340 136 / 229 / 288 4.1 / 10.1 / 15.3 1.620 / 3.070 / 4.090 1.260 / 2.160 / 3.000 279 / 528 / 705 4.1 / 13 / 22.4 2.050 / 3.940 / 5.400 1.470 / 2.790 / 3.690 1.150 / 1.970 / 2.690 254 / 480 / 635 3.5 / 10.9 / 18.4 2.370 / 3.760 / 4.810 204 / 324 / 414 7.5 / 16.8 / 26.1 2.630 / 4.180 / 5.460 1.790 / 2.960 / 4.030 452 / 721 / 941 10.4 / 25.2 / 42.2 2.360 / 3.970 / 5.270 2.410 / 3.830 / 4.980 1.640 / 2.700 / 3.660 414 / 660 / 857 8.8 / 21.3 / 35.2 2.340 / 3.580 / 4.530 201 / 308 / 391 9.1 / 18.5 / 27.9 3.100 / 5.840 / 6.620 2.170 / 4.280 / 5.030 533 / 1006 / 1140 4 / 13.9 / 17.9.8 4.140 / 7.370 / 8.720 2.840 / 5.260 / 5.980 1.980 / 3.840 / 4.490 490 / 906 / 1030 3.4 / 11.3 / 14.6 4.240 / 5.900 / 7.050 365 / 508 / 607 23.1 / 41.1 / 56.5 4.710 / 6.650 / 9.140 3.480 / 4.930 / 6.990 811 / 1146 / 1.575 12.3 / 22.6 / 40.3 6.520 / 9.250 / 12.580 4.560 / 6.490 / 9.030 3.360 / 4.790 / 6.880 785 / 1117 / 1555 11.6 / 21.7 / 39.6 6.660 / 9.440 / 11.790 573 / 813 / 1016 17 / 31.9 / 48.1 Sound power level db(a) 33 / 41 / 47 32 / 44 / 51 40 / 53 / 59 29 / 46 / 53 36 / 48 / 57 40 / 52 / 58 46 / 59 / 63 52 / 57 / 66 Sound pressure level 4 db(a) 19 / 24 / 31 16 / 28 / 35 24 / 37 / 43 14 / 30 / 37 20 / 33 / 41 24 / 36 / 42 30 / 43 / 47 34 / 41 / 49 NR 4 db(a) 10 / 15 / 22 5 / 20 / 26 14 / 28 / 34 5 / 22/ 27 9 / 22 / 31 14 / 28 / 34 21 / 33 / 36 26 / 34 / 48 Sound Levels - 4 Pipes Sound power level db(a) 33 / 41 / 47 32 / 44 / 51 40 / 53 / 59 29 / 46 / 53 36 / 48 / 57 40 / 52 / 58 46 / 59 / 63 52 / 57 / 66 Sound pressure level 4 db(a) 19 / 24 / 31 16 / 28 / 35 24 / 37 / 43 14 / 30 / 37 20 / 33 / 41 24 / 36 / 42 30 / 43 / 47 34 / 41 / 49 NR 4 db(a) 10 / 15 / 22 5 / 20 / 26 14 / 28 / 34 5 / 22/ 27 9 / 22 / 31 14 / 28 / 34 21 / 33 / 36 26 / 34 / 48 Fans Number 1 1 1 2 2 2 2 3 Airflow - 2 Pipes Airflow - 4 Pipes m³/h m³/h 111 / 190 / 283 95 / 168 / 253 105 / 179 / 265 89 / 161 / 241 229 / 388 / 483 214 / 366 / 450 172 / 356 / 493 162 / 333 / 461 253 / 486 / 716 242 / 466 / 671 350 / 640 / 933 334 / 614 / 885 480 / 893 / 1064 470 / 859 / 1012 660 / 936 / 1397 634 / 905 / 1370 Electrical Data Power supply V/Ph/ Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz Fan consumption-2 Pipes W 14 / 24 / 36 14 / 23 / 35 24 / 50 / 81 18 / 39 / 59 33 / 57 / 80 39 / 76 / 111 60 / 114 / 161 90 / 112 / 188 Fan consumption-4 Pipes W 14 / 24 / 36 14 / 23 / 34 24 / 50 / 80 18 / 39 / 58 33 / 56 / 78 39 / 75 / 110 60 / 113 / 159 90 / 112 / 188 Electrical heater (max) W 500 500 500/1.000 1.250/2.500 1.250/2.500 1.250/2.500 1.000/2.000 1.500/3.000 Water Connections Gas female threaded Cooling coil inches 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Heating coil inches 1/2 Dimensions LxWxH SVN LxWxH SHN mm mm 677 x 220 x 430 677 x 430 x 220 677 x 220 x 430 677 x 430 x 220 862 x 220 x 430 862 x 430 x 220 1.047 x 220 x 430 1.047 x 430 x 220 1.232 x 220 x 430 1.232 x 430 x 220 1.417 x 220 x 430 1.417 x 430 x 220 1.232 x 220 x 530 1.232 x 530 x 220 1.425 x 220 x 530 1.425 x 530 x 220 Weight Unit weight SVN kg 12 12 14.5 20 22 26 27 41 Unit weight SHN kg 13 13 15.5 22 24 28 29 43 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 According to Eurovent standard. Air: 20 C, Water in: 70 C/60 C. 4 Informative data, considering a sound attenuation of the room and installation of 16dBA. on stock! Configuration: 2 or 4-pipes, terminal block, without valve, left service side without brand. Accessories for customization on site also available on stock. Please consult us to get the last updated information on leadtime.
210 Water Terminals Fan coils units Cooling and heating SysCoil 2 VN/HN EC 0.48-10.0 kw EC Motor 0.79-12.7 kw HOTEL OFFICES Technical features Cooling Capacity from 0.48 to 10.0 kw Heating Capacity from 0.79 to 12.7 kw 7 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration VN Vertical concealed units without cabinet HN Ceiling concealed units without cabinet Product Advantages Ease of installation Streamlined design and elaborate finish enabling harmonious integration 5-speed AC fan motor Very low operating acoustical levels Airflow rate between 84 and 1.548 m³/h Extended monobloc condensate drain pan Main accessories and options EC motor Selection of 3 speed Electrical heater On-board electronic control or terminal block for wall-mounted control Modbus communication interface board 2-way or 3-way ON/OFF valve Condensate drain pump G3 filter Fuse holder Selection of service side Large choice of controls : Electro-mechanic, electronic, onboard or wall-mounted Suspension kit Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 5 bars 5 C/15% RH 32 C/70% RH
Water Terminals 211 Technical feature Syscoil 2 VN/HN EC SC10 SC20 SC30 SC40 SC50 SC60 SC70 SC80 Capacities - 2 Pipes V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 V1 / V3 / V5 Cooling 1 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating Heating 2 capacity Capacities - 4 Pipes Cooling 1 Heating 2 Total cooling capacity Sensible capacity Water flow Water pressure drop Heating capacity Water flow Water pressure drop Sound Levels - 2 Pipes W W l/h kpa W W W l/h kpa W l/h kpa 580 / 1.080/ 1.790 460 / 870 / 1.490 100 / 186 / 309 2.7 / 8.5 / 22.1 790 / 1.510 / 2.570 480 / 920 / 1.560 370 / 740 / 1280 82/ 159 / 268 1.9 / 6.4 / 17 810 / 1.410 / 2.220 69 / 121 / 191 1 / 2.4 / 6 660 / 1.350 / 2.160 490 / 1.050 / 1.770 114 / 232 / 373 1.6 / 4.5 / 9.6 810 / 1.750 / 2.940 550 / 1.130 / 1.930 410 / 870 / 1.550 95 / 195 / 333 1.2 / 3.4 / 8 930 / 1.560 / 2.280 80 / 135 / 197 1 / 2.7 / 5.7 670 / 1.610 / 2.430 560 / 1.360 / 2.040 115 / 277 / 418 1.7 / 7.1 / 14.6 980 / 2.150 / 3.310 500 / 1.370 / 2.130 410 / 1.150 / 1.790 87 / 235 / 366 1.1 / 5.4 / 11.5 1.680 / 2.420 / 2.890 145 / 209 / 249 4.2/ 7.6 / 10.1 1.270 / 2.660 / 3.720 940 / 1.760 / 2.670 218 / 457 / 642 5.9 / 20.4 / 37.4 1.310 / 2.850 / 4.900 1.090 / 2.320 / 3.370 830 / 1.560 / 2.390 189 / 400 / 580 4.7 / 16.1 / 31 2.030 / 3.440 / 4.470 175 / 296 / 385 6.3 / 16.1 / 26.3 1.260 / 3.810 / 4.400 1.060 / 2.740 / 3.350 217 / 657 / 759 2.6 / 19.6 / 25.8 1.580 / 4.910 / 5.800 1.090 / 3.300 / 3.970 930 / 2.390 / 2.970 188 / 568 / 685 2.1 / 14.9 / 21.2 2.570 / 3.980 / 4.980 221 / 342 / 429 8.6 / 18.5 / 27.9 2.060 / 4.610 / 5.370 1.370 / 3.320 / 3.960 355 / 794 / 925 6.6 / 30.4 / 40.8 1.780 / 4.420 / 5.170 1.750 / 4.080 / 4.810 1.150 / 2.990 / 3.520 301 / 703 / 829 4.9/ 24.1/ 33 1.770 / 3.790 / 4.400 152 / 326 / 379 5.8 / 20.3 / 26.4 2.590 / 5.520 / 6.510 1.810 / 3.970 / 4.870 446 / 951 / 1122 2.8 / 12.5 / 17.3 3.640 / 6.870 / 8.460 2.190 / 4.730 / 5.710 1.530 / 3.400 / 4.220 377 / 816 / 983 2/ 9.2 / 13.3 4.040 / 5.640 / 6.830 348 / 486 / 588 21.3 / 38 / 53.3 4.880 / 6.590 / 9.150 3.620 / 4.890 / 6.990 841 / 1135 / 1575 13.1 / 22.2 / 40.3 6.740 / 9.170 / 12.580 4.740 / 6.340 / 10.000 3.500 / 4.680 / 7.690 817 / 1092 / 1722 12.5 / 20.8 / 47.8 6.920 / 9.220 / 12.700 596 / 794 / 1093 18.2 / 30.5 / 55.2 Sound power level db(a) 40 / 49 / 61 36 / 50 / 62 33 / 54 / 62 31 / 45 / 57 34 / 52 / 58 34/ 55 / 59 40 / 54 / 59 53 / 58 / 66 Sound pressure level 4 db(a) 25 / 33 / 45 20 / 34 / 46 17 / 37 / 46 15 / 29 / 41 19 / 36 / 42 18 / 39 / 43 24 / 38 / 43 33 / 39 / 49 NR 4 db(a) 16 / 24 / 35 10 / 26 / 35 10 / 28 / 37 5 / 20 / 32 5 / 28 / 33 6 / 30 / 33 14 / 28 /33 23 / 31 /42 Sound Levels - 4 Pipes Sound power level db(a) 40 / 49 / 61 36 / 50 / 62 33 / 54 / 62 30 / 45 / 57 34 / 52 / 58 34 / 55 / 59 40 / 54 / 59 53 / 58 / 66 Sound pressure level 4 db(a) 25 / 33 / 45 20 / 34 / 46 17 / 37 / 46 15 / 29 / 41 19 / 36 / 42 18 / 39 / 43 24 / 38 / 43 33 / 39 / 49 NR 4 db(a) 16 / 24 / 35 10 / 26 / 35 10 / 28 / 37 5 / 20 / 32 5 / 28 / 33 6 / 30 / 33 14 / 28 /33 23 / 31 /42 Fans (LS/MS/HS) Number 1 1 1 2 2 2 2 3 Airflow - 2 Pipes Airflow - 4 Pipes m³/h m³/h 108 / 228 / 417 91 / 199 / 379 98 / 234 / 413 84 / 200 / 380 185 / 384 / 570 155 / 346 / 526 163 / 385 / 667 144 / 349 / 615 203 / 645 / 816 185 / 587 / 755 245 / 737 / 912 205 / 668 / 845 417 / 827 / 1028 390 / 777 / 969 685 / 927 / 1398 660 / 884 / 1548 Electrical Data (LS/MS/HS) Power supply V/Ph/ Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz Fan consumption-2pipes W 8 / 14 / 41 8 / 15 / 41 6 / 19 / 46 2 / 12 / 43 2 / 24 / 46 2 / 30 / 54 12 / 45 / 77 23 / 42 / 108 Fan consumption-4pipes W 8 / 14 / 39 8 / 15 / 40 6 / 18 / 45 2 / 12 / 41 2 / 23 / 44 2 / 28 / 52 12 / 44 / 74 22 / 41 / 116 Set voltage V 2 / 5 / 10 2 / 5 / 10 2 / 6 / 10 2 / 5 / 10 2 / 7 / 10 2 / 7 / 10 4 / 8 / 10 3 / 4.1 / 6 Electrical heater (max) W 500 500 500/1.000 1.250/2.500 1.250/2.500 1.250/2.500 1.000/2.000 1.500/3.000 Water Connections Gas female threaded Cooling coil inches 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 Heating coil inches 1/2 Dimensions LxWxH SVN LxWxH SHN mm mm 677 x 220 x 430 677 x 430 x 220 677 x 220 x 430 677 x 430 x 220 862 x 220 x 430 862 x 430 x 220 1.047 x 220 x 430 1.047 x 430 x 220 1.232 x 220 x 430 1.232 x 430 x 220 1.417 x 220 x 430 1.417 x 430 x 220 1.232 x 220 x 530 1.232 x 530 x 220 1.425 x 220 x 530 1.425 x 530 x 220 Weight Unit weight SVN kg 12 12 14.5 20 22 26 27 41 Unit weight SHN kg 13 13 15.5 22 24 28 29 43 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 According to Eurovent standard. Air: 20 C, Water in: 70 C/60 C. 4 Informative data, considering a sound attenuation of the room and installation of 16dBA.
212 Water Terminals 4-way chilled water cassette Cooling and heating KOG LN 3.3-9.9 kw 2.2-11.6 kw HOTEL OFFICES Technical features Cooling Capacity from 3.3 to 9.9 kw Heating Capacity from 2.2 to 11.6 kw 5 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration Cassette Product Advantages Design for suspended celing integration 600x600 (9, 12 and 18 models) and 600x1.200 formats, (30 and 45 models) Low built-in height: 287 mm Direct access to electrical connection on sliding chassis Integrated valve and electrical connections 3-speed AC fan motor Very low operating acoustical levels with new low noise LN versions Fresh air intake Air distribution in adjacent room Integrated condensate drain lift pump up to 600 mm, (3-top for 9, 12 and 18 models) Infra-red remote control version with valve and change-over Galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation Possibility to close one or two discharge flaps Cleanable synthetic-type air filter Main accessories and options 3-row coil for optimized cooling performances Electrical heater with inserted heating rod 2-stage heater available with Aquanet control AC motor Large choice of control: Aquanet control or wall-mounted thermostat 2-way or 3-way ON/OFF valve Relay Fuse holder ModBus Communication interface board Design metallic panel with 192 colours and Coanda air diffusion (9-12-18 models) Valve Aquanet control Solid ceiling frame Condensate drain pump Auxiliary condensate drain pan Master and slaves control, up to 4 units max Selection software Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature +5 C Maximum water temperature +70 C (size 09-12-18) +60 C (size 30/45) Maximum operating pressure 15 bars Heating mode Minimum indoor air temperature (room/intake/around unit) 13 C/15% RH Maximum indoor air temperature (room/intake/around unit) 32 C/70% RH
Water Terminals 213 Technical feature KOG LN Size 09 LN 12 LN 18 LN 30 LN 45 LN Capacities - 2 PIPE Nominal V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Cooling 1 Total cooling capacity Sensible capacity Water flow W W l/h 1.600 / 1.900 / 2.300 1.250 / 1.500 / 1.800 280 / 330 / 400 2.300 / 2.600 / 3.500 1.700 / 2.050 / 2.900 400 / 450 / 600 2.800 / 3.700 / 4.600 2.150 / 2.950 / 3.850 480 / 640 / 790 4.150 / 5.611 / 6.840 3.350 / 4.591 / 5.660 715 / 966 / 1.178 5.414 / 7.039 / 9.298 4.329 / 5.728 / 7.650 933 / 1.212 / 1.602 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16 8 /14 / 21 4/ 12,5 / 20 Heating 2 Heating capacity W CapacitIEs - 4 PIPE Cooling 1 Heating 3 Nominal Total cooling capacity Sensible capacity Water flow W W l/h 2.100 / 2.500 / 3.100 1.600 / 1.900 / 2.300 1.250 / 1.500 / 1.800 280 / 330 / 400 2.700 / 3.200 / 4.500 2.300 / 2.600 / 3.500 1.700 / 2.050 / 2.900 400 / 450 / 600 3.300 / 4.600 / 5.700 2.800 / 3.700 / 4.600 2.150 / 2.950 / 3.850 480 / 640 / 790 5.300 / 7.500 / 9.400 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16 - Heating capacity Water flow W l/h 1.700 / 1.900 / 2.200 160 / 180 / 210 2.200 / 2.500 / 3.335 200 / 220 / 290 3.300 / 3.950 / 4.470 290 / 340 / 380 Water pressure drop kpa 5 13 28 - - - - - - 4.600 / 7.400 / 10.000 5.716 / 7.925 / 9.887 4.324 / 6.185 / 7.655 985 / 1.365 / 1.703 10,5 / 18,5 / 28 6.586 / 7.506 / 8.980 577 / 658 / 788 Sound Levels (LS/MS/HS) Sound power level db(a) 34 / 40 / 50 34 / 40 / 50 41 / 49 / 57 44 / 52 / 58 39 / 50 / 57 Sound pressure level 4 db(a) 26 / 32 / 42 26 / 32 / 42 33 / 41 / 49 31,9 / 40,6 / 49,3 46 / 54 / 62 NR 4 db(a) 20 / 27 / 37 20 / 27 / 37 28 / 35 / 43 29 / 36 / 44 35 / 42 / 50 Fans (LS/MS/HS) Number 1 1 1 2 2 Airflow m³/h 330 / 450 / 720 330 / 450 / 720 410 / 580 / 830 Electrical Data (LS/MS/HS) Power supply V/Ph/Hz 230V / 1~ / 50Hz 469 / 668 / 902 5 / 6/ 8 547 / 707 / 907 Water Terminals Fan consumption - STD W 20 / 30 / 50 20 / 30 / 50 21 / 30 / 46 / 71 38 / 66 / 100 58/90/136 (2pipes) 63/91/140 (4pipes) Electrical heater W 1.500 1.800 2.400 2.800 2.800 Water Connections Gas male threaded Cooling coil (2 tubes cooling or heating/ 4 tubes cooling) inches 1/2 2 1/2 3/4 1 1 Heating coil (4 tubes heating) inches 1/2 1/2 1/2-1/2 Dimensions Casing (LxWxH) mm 571 x 571 x 287 1.171 x 571 x 287 Plastic Grille (LxWxH) mm 625 x 625 x 40 1.225 x 625 x 40 Weight Unit weight kg 26 28 29 49 55 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 Air: 20 C, Water in: 70 C/60 C. 4 Sound pressure considering a local of 100 m 3, a reverberation time of 0,5 sec and a distance of 1 m.
214 Water Terminals 4-way chilled water cassette Cooling and heating KOG LN EC 2.2-8.6 kw Motor EC 2.0-8.3 kw HOTEL OFFICES Technical features Cooling Capacity from 2.2 to 8.6 kw Heating Capacity from 2.0 to 8.3 kw 5 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration Cassette Product Advantages Designed for suspended ceiling integration Design for suspended celing integration 600x600 (9, 12 and 18 models) and 600x1.200 formats, (30 and 45 models) Low built-in height: 287 mm Direct access to electrical connection on sliding chassis Integrated valve and electrical connections Low consumption EC fan motor Very low operating acoustical levels with new low noise LN versions Fresh air intake Air distribution in adjacent room Integrated condensate drain lift pump up to 600 mm, (3-top for 9, 12 and 18 models) Infra-red remote control version with valve and change-over Galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation Possibility to close one or two discharge flaps Cleanable synthetic-type air filter Main accessories and options 3-row coil for optimized cooling performances Electrical heater with inserted heating rod 2-stage heater available with Aquanet control EC motor Selection of 3 speed with ECoSpeed3 board Large choice of control: Aquanet control or wall-mounted thermostat 2-way or 3-way ON/OFF valve G1 filter Condensate drain pump Relay Fuse holder ModBus Communication interface board Design metallic panel with 192 colours and Coanda air diffusion (9-12-18 models) Valve Aquanet control Solid ceiling frame Condensate drain pump Auxiliary condensate drain pan Select it Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature +5 C Maximum water temperature +70 C (size 09-12-18) +60 C (size 30/45) Maximum operating pressure 15 bars Heating mode Minimum indoor air temperature (room/intake/around unit) 13 C/15% RH Maximum indoor air temperature (room/intake/around unit) 32 C/70% RH
Water Terminals 215 Technical feature KOG LN EC 09 LN 12 LN 18 LN 30 LN 45 LN Capacities - 2 PIPE NOMINAL Cooling 1 Total cooling capacity Sensible capacity Air flow W W l/h 1.600 / 1.900 / 2.300 1.250 / 1.500 / 1.800 280 / 330 / 400 2.300 / 2.600 / 3.500 1.700 / 2.050 / 2.900 400 / 450 / 600 2.800 / 3.700 / 4.600 2.150 / 2.950 / 3.850 480 / 640 / 790 4.215 / 5.700 / 6.800 3.400 / 4.600 / 5.700 725 / 982 / 1.171 3.730 / 5.900 / 7.980 2.920 / 4.700 / 6.500 642 / 1.016 / 1.375 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16 8 / 13 / 18 4 / 9 / 15 Heating 2 Heating capacity W Capacities - 4 PIPE NOMINAL Total cooling capacity W 2.100 / 2.500 / 3.100 1.600 / 1.900 / 2.300 2.700 / 3.200 / 4.500 2.300 / 2.600 / 3.500 3.300 / 4.600 / 5.700 2.800 / 3.700 / 4.600 5.300 / 7.500 / 9.400-4.600 / 7.400 / 10.000 4.000 / 6.490 / 8.600 Cooling 1 Sensible capacity Air flow W l/h 1.250 / 1.500 / 1.800 280 / 330 / 400 1.700 / 2.050 / 2.900 400 / 450 / 600 2.150 / 2.950 / 3.850 480 / 640 / 790 - - 3.050 / 5.000 / 6.700 689 / 1.118 / 1.481 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16-6 / 13 / 22 Heating 3 Heating capacity Air flow W l/h 1.700 / 1.900 / 2.200 160 / 180 / 210 2.200 / 2.500 / 3.335 200 / 220 / 290 3.300 / 3.950 / 4.470 290 / 340 / 380 - - 4.700 / 6.790 / 8.300 405 / 585 / 715 Water pressure drop kpa 3 / 4 / 5 7 / 9 / 13 17 / 24 / 28-3 / 5 / 7 Sound Levels (LS/MS/HS) Sound power level db(a) 34 / 40 / 50 34 / 40 / 50 41 / 49 / 57 44 / 52 / 58 39 / 50 / 57 Sound pressure level 4 db(a) 26 / 32 / 42 26 / 32 / 42 33 / 41 / 49 36 / 44 / 50 31 / 42 / 49 NR 4 db(a) 20 / 27 / 37 20 / 27 / 37 28 / 35 / 43 33 / 40 / 44 25 / 36 / 43 Fans (LS/MS/HS) Number 1 1 1 2 2 Airflow m³/h 330 / 450 / 720 330 / 450 / 720 410 / 580 / 830 597 / 928 / 1.313 521 / 877 / 1.268 Electrical Data (LS/MS/HS) Power supply V/Ph/Hz 230V / 1~ / 50Hz Fan consumption - STD W 8 / 11 / 26 8 / 11 / 26 9 / 23 / 41 9 / 17 / 39 9 / 17 / 23 Set Voltage V 3.77/4.39/6.17 3.77/4.39/6.17 4.45/6.03/7.53 3.09/1.44/5.48 3.09/4.11/5.48 Electrical heater (max) W 1.500 1.800 2.400 2.800 2.800 Water Connections Gas male threaded Cooling coil (2 tubes cooling or heating / 4 tubes cooling) inches 1/2 1/2 3/4 1 1 Heating coil (4 tubes heating) inches 1/2 1/2 1/2-1/2 Dimensions Casing (LxWxH) mm 571 x 571 x 287 571 x 571 x 287 571 x 571 x 287 1.171 x 571 x 287 1.171 x 571 x 287 IRYS Diffuser (LxWxH) mm 595 x 595 x 40 595 x 595 x 40 595 x 595 x 40 1.195 x 595 x 40 1.195 x 595 x 40 Weight Unit weight kg 26 28 29 49 55 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 Air: 20 C, Water in: 70 C/60 C. 4 Sound pressure considering a local of 100 m 3, a reverberation time of 0,5 sec and a distance of 1 m.
216 Water Terminals 1-way chilled water cassette Coanda effect KCO2 1.1-3.3 kw Motor EC 1.3-3.4 kw HOSPITAL Technical features Cooling Capacity from 1.1 to 8.6 kw Heating Capacity from 1.3 to 3.4 kw 3 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration Cassette Product Advantages Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspended ceiling installation Possible gravity condensate evacuation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers with high induction 5 speed AC fan motor Very low acoustic levels Galvanized steel sheet with acoustical insulation Air filtration Main options 3-row coil for optimized cooling performances Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Selection softwar: select KCO2 False ceiling integration Orientable diffusor with Coanda effect Operating limit (to be confirmed following selection software issue) KCO2 Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars
Water Terminals 217 Technical feature KCO2 60 90 120 Capacities - 2 PIPE (LS/MS/HS) Cooling 1 Total cooling capacity W 880 / 1.060 / 1.500 1.370 / 1.620 / 2.370 1.970 / 2.840 / 3.340 Sensible capacity W 660 / 810 / 1.180 1.000 / 1.190 / 1.770 1.440 / 2.110 / 2.510 Water flow l/h 163 / 196 / 279 253 / 299 / 437 363 / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating (2) Heating capacity W 1.080 / 1.330 / 1.930 1.600 / 1.910 / 2.860 2.300 / 3.370 / 4.020 Capacities - 4 PIPE (LS/MS/HS) Cooling 1 Total cooling capacity W 880 / 1.060 / 1.500 1.370 / 1.620 / 2.370 1.970 / 2.840 / 3.340 Sensible capacity W 660 / 810 / 1.180 1.000 / 1.190 / 1.770 1.440 / 2.110 / 2.510 Water flow l/h 163 / 196 / 279 253 / 299 / 437 363 / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating 3 Water flow l/h 79 / 93 / 126 128 / 147 / 202 182 / 247 / 284 Heating capacity W 920 / 1.080 / 1.470 1.490 / 1.710 / 2.350 2.120 / 2.870 / 3.300 Water pressure drop kpa 1,6 / 2,1 / 3,6 0,9 / 1,2 / 2,0 2,0 / 3,4 / 4,3 Sound Levels (LS/MS/HS) Sound power level db(a) 35 / 41 / 52 33 / 36 / 48 35 / 46 / 52 Sound pressure level 4 db(a) 26 / 32 / 43 24 / 27 / 39 26 / 37 / 43 NR 4 db(a) 22 / 28 / 39 20 / 23 / 35 22 / 33 / 39 Fans (LS/MS/HS) Airflow m³/h 140 / 180 / 280 200 / 240 / 380 290 / 440 / 540 Electrical Data (LS/MS/HS) Power supply V / Ph / Hz 230V / 1~ / 50Hz Fan consumption - STD W 16 / 22 / 49 24 / 27 / 44 27 / 42 / 59 Electrical heater W 550 1.100 1.400 Water Connections Gas male threaded Cooling coil inches 1/2 1/2 1/2 Heating coil inches 1/2 1/2 1/2 Dimensions Casing (LxWxH) mm 592 x 592 x 309 592 x 970 x 309 592 x 1.192 x 309 Water Terminals 1 According to Eurovent standard. Air: 27 C BS / 19 C BH, Eau: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water: 70 C/60 C. 3 Sound pressure considering a local attenuation of 9 db for a volume of 100 m 3 with a reverberation time of 0,5 sec.
218 Water Terminals 1-way chilled water cassette Coanda effect KCO2 EC 0.8-3.8 kw Motor EC 1.0-4.5 kw HOSPITAL Technical features Cooling Capacity from 0.8 to 3.8 kw Heating Capacity from 1.0 to 4.5 kw 3 sizes Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes Configuration Cassette Product Advantages EC motor with very long consumption Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspensed ceilling installation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers High including diffusion grille Main options EC motor Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Select KCO2 False ceiling integration Orientable diffusor with Coanda effect Operating limit (to be confirmed following selection software issue) KCO2 EC Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars
Water Terminals 219 Technical feature KCO2 EC 60 90 120 Capacities - 2 PIPE (LS/MS/HS) Cooling 1 Total cooling capacity W 890 / 1.180 / 1.560 1.460 / 2.310 / 3.160 1.870 / 2.780 / 3.750 Sensible capacity W 620 / 910 / 1.240 1.070 / 1.730 / 2.410 1.370 / 2.060 / 2.830 Water flow l/h 153 / 218 / 291 240 / 428 / 585 346 / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating 2 Heating capacity W 1.020 / 1.500 / 2.020 1.720 / 2.790 / 3.850 2.190 / 3.300 / 4.540 Capacities - 4 PIPE (LS/MS/HS) Cooling 1 Total cooling capacity W 8.920 / 1.180 / 1.560 1.460 / 2.310 / 3.160 1.870 / 2.780 / 3.750 Sensible capacity W 620 / 910 / 1.240 1.070 / 1.730 / 2.410 1.370 / 2.060 / 2.830 Water flow l/h 153 / 218 / 291 240 / 428 / 585 346 / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating 3 Water flow l/h 75 / 101 / 131 136 / 199 / 259 175 / 243 / 313 Heating capacity W 870 / 1.180 / 1.520 1.580 / 2.310 / 3.010 2.040 / 2.820 / 3.640 Water pressure drop kpa 1,4 / 2,5 / 3,8 1,0 / 2,0 / 3,1 1,8 / 3,3 / 5,1 Sound Levels (LS/MS/HS) Sound power level db(a) 35 / 46 / 55 34 / 46 / 56 36 / 48 / 58 Sound pressure level 4 db(a) 26 / 37 / 46 25 / 37 / 47 27 / 39 / 49 NR 4 db(a) 22 / 33 / 42 21 / 33 / 43 23 / 35 / 45 Fans (LS/MS/HS) Airflow m³/h 130 / 205 / 295 215 / 370 / 540 275 / 430 / 620 Electrical Data (LS/MS/HS) Power supply V / Ph / Hz 230V / 1~ / 50Hz Absorbed power W 8 / 14 / 29 34 / 46 / 56 36 / 48 / 58 Electrical heater W 550 1.100 1.400 Water Connections Gas male threaded Cooling coil inches 1/2 1/2 1/2 Heating coil inches 1/2 1/2 1/2 Dimensions Casing (LxWxH) mm 592 x 592 x 309 592 x 970 x 309 592 x 1.192 x 309 Water Terminals 1 According to Eurovent standard. Air: 27 C BS / 19 C BH, Eau: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water: 70 C/60 C. 3 Sound pressure considering a local attenuation of 9 db for a volume of 100 m 3 with a reverberation time of 0,5 sec.
220 Water Terminals High wall chilled water unit cooling and heating HAWAIR 2.2-4.7 kw 2.0-5.9 kw HOTEL Technical features Cooling Capacity from 2.2 to 4.7 kw Heating Capacity from 2.0 to 5.9 kw 4 sizes Versions 2-Pipes Configuration High Wall Product Advantages Aesthetic design suitable for home and hotel applications Silent unit for optimum customer comfort Version with Integrated 3-way valve and IR control Choice between IR or wall-mounted thermostat Coil with hydrophilic fins to improve the condensate flow Light unit for easy installation Very easy servicing through removable front plate Cleanable synthetic-type air filter Indoor unit compatible with all Systemair Airwell chilled water production units Main options and accessories RC-08A IR control Terminal block for wall-mounted thermostat Version with 3-way ON/OFF valve 3-speed tangential fan motor Motorized flap Electro-static anti-bacteria filter Pipe connectors Drilling template Valve Aquanet control Wall-mounted thermostat Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +60 C 15 bars 6 C/15% RH 32 C/70% RH
Water Terminals 221 Technical feature HAWAIR HWA007 HWA009 HWA018 HWA022 Capacities Nominal Total cooling capacity W 1.650 / 1.900 / 2.200 1.700 / 2.000 / 2.900 2.900 / 3.300 / 3.600 3.400 / 4.000 / 4.700 Sensible capacity W 1.400 / 1.640 / 1.870 1.500 / 1.700 / 2.400 2.400 / 2.650 / 3.000 2.800 / 3.300 / 3.700 Cooling 1 Water flow l/h 290 / 320 / 400 310 / 360 / 500 490 / 560 / 620 590 / 690 / 810 Water pressure drop kpa 3 / 6 / 10 5 / 10 / 16 20 / 27 / 35 27 / 36 / 50 Heating 2 Heating capacity W 2.000 / 2.300 / 2.900 2.050 / 2.350 / 3.700 3.800 / 4.300 / 4.800 4.250 / 4.900 / 5.850 Sound Levels (LS/MS/HS) Sound power level db(a) 36 / 40 / 44 38 / 42 / 48 45 / 48 / 52 50 / 54 / 58 Sound pressure lesvel 4 db(a) 24 / 32 / 36 30 / 34 / 40 37 / 40 / 44 42 / 46 / 50 NR 4 db(a) 19 / 27 / 31 25 / 29 / 35 32 / 35 / 39 37 / 41 / 45 Fans (LS/MS/HS) Number 1 1 1 1 Airflow m³/h 320 / 380 / 450 400 / 500 / 600 550 / 650 / 750 650 / 750 / 900 Electrical Data (LS/MS/HS) Power supply V/Ph/Hz 230V / 1~ / 50Hz Fan consumption W 22 / 26 / 28 22 / 26 / 28 25 / 28 / 31 43 / 47 / 58 Water Connections Gas female threaded Coil inches 1/2 1/2 1/2 1/2 Dimensions Weight Casing (LxWxH) mm 845 x 275 x 180 845 x 275 x 180 940 x 298 x 200 940 x 298 x 200 Unit weight 11 11 13 13 Water Terminals 1 According to Eurovent standard. Air: 27 C DB/19 C WB, Water in: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, Water in: 50 C, same water flow as in cooling. 3 Sound pressure considering a local of 100 m 3, a reverberation time of 0,5 sec and a distance of 1 m.
222 Water Terminals Pressure ductable fan coil unit cooling and heating DUCTYS 0.5-6.8 kw Motor EC 0.6-8.8 kw OFFICES Technical features Cooling Capacity from 0.5 to 6.8 kw Heating Capacity: from 0.6 to 8.8 kw 5 sizes Versions 2-Pipes 2 pipes/2-wires 4-pipes Configuration Ceiling concealed Product Advantages EC fan motor with very low consumption Very low height (223 mm) Ease of installation and maintenance In-line or same side (U-type) airflow diffusion Static pressure available up to 100 Pa Very low operating acoustical levels Selection of hydraulic and electric service side Configuration flexibility thanks to modular conception Various air intake and discharge configuration: rectangular or duct connections Main options and accessories EC motor Electrical heater with inserted heating rod On-board electronic control or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Ducted or rectangular plenum for air intake or dischage Fresh air intake Condensate drain pump G2 filter Many aeraulic configurations Fuse holder 2-way or 3-way ON/OFF valve Large choice of controls: Electro-mechanic, electronic, on-board or wall-mounted IR control Suspension kit and Selection software Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 10 bars 5 C/15% RH 32 C/70% RH
Water Terminals 223 Technical feature DUCTYS DT10 DT15 DT20 DT25 DT40 Capacities - 2 tubes Cooling 1 Total cooling capacity Sensible capacity W W 597 / 1.567 / 1.890 497 / 1.323 / 1.608 1.230 / 1.700 / 1.970 1.130 / 1.540 / 1.820 1.720 / 2.230 / 2.460 1.460 / 1.950 / 2.250 2.450 / 2.810 / 3.260 1.990 / 2.280 / 2.690 2.190 / 4.680 / 5.490 1.720 / 3.730 / 4.400 Available static pressure Pa 5 / 28 / 48 19 / 50 / 80 26 / 50 / 66 32 / 50 / 66 7 / 50 / 72 Water flow l/h 103 / 270 / 325 210 / 290 / 340 305 / 380 / 430 420 / 480 / 565 400 / 854 / 1.002 Water pressure drop kpa 1 / 3 / 5 4 / 7 / 9 8 / 13 / 15 16 / 21 / 28 7 / 27 / 36 Heating 2 Total heating capacity W Capacities - 4 tubes Cooling 1 Total cooling capacity Sensible capacity W W 672 / 1.884 / 2.359 591 / 1.522 / 1.826 492 / 1.283 / 1.551 1.600 / 2.260 / 2.790 1.190 / 1.610 / 1.920 1.080 / 1.470 / 1.750 2.410 / 2.930 / 3.100 1.670 / 2.190 / 2.390 1.420 / 1.930 / 2.150 3.070 / 3.600 / 4.020 2.220 / 2.730 / 3.010 1.760 / 2.200 / 2.460 2.570 / 5.430 / 6.340 1.790 / 3.760 / 4.450 1.931 / 4.049 / 4.799 Available static pressure Pa 5 / 28 / 48 18 / 50 / 72 25 / 50 / 64 31 / 50 / 55 6 / 50 / 77 Water flow l/h 102 / 262 / 314 205 / 280 / 330 290 / 380 / 410 380 / 470 / 520 388 / 804 / 948 Water pressure drop kpa 1 / 3 / 5 4 / 7 / 9 8 / 13 / 15 13 / 20 / 23 7 / 24 / 31 655 / 2.230 / 3.170 / 3.580 / 3.235 / Total heating capacity W 1.806 / 2.250 2.850 / 3.220 3.460 / 3.540 4.220 / 4.540 5.946 / 6.559 Heating 3 Water flow l/h 56 / 156 / 194 190 / 250 / 280 270 / 300 / 310 310 / 365 / 390 279 / 512 / 565 Water pressure drop kpa 1 / 4 / 7 6 / 9 / 12 12 / 16 / 17 15 / 21 / 24 2 / 16 / 18 Sound Level (PV/MV/GV) Sound power Inlet + Rad db(a) 27 / 47 / 53 44 / 52 / 60 50 / 57 / 61 50 / 55 / 61 45 / 58 / 63 Sound power Outlet db(a) 27 / 46 / 52 45 / 56 / 62 48 / 57 / 61 50 / 56 / 61 38 / 59 / 64 Sound pressure 4 db(a) 20 / 36 / 41 26 / 35 / 42 28 / 36 / 40 32 / 36 / 43 34 / 44 / 50 NR 4 <15 / 23 / 30 21 / 30 / 37 23 / 31 / 35 27 / 31 / 38 21 / 35 / 40 Ventilation Air flow 2-tubes m 3 /h 90 / 280 / 370 270 / 400 / 505 370 / 520 / 600 440 / 550 / 640 299 / 741 / 915 Air flow 4-tubes m 3 /h 89 / 269 / 350 265 / 380 / 480 360 / 510 / 575 410 / 525 / 595 350 / 812 / 1.008 Electrical Data (PV/MV/GV) Alimentation V/Ph/Hz 230V / 1~ / 50Hz-60Hz Power consumption W 9 / 14 / 38 8 / 30 / 60 18 / 47 / 72 26 / 41 / 64 10 / 65 / 114 Voltage V 2,0 / 7,1 / 9,6 3,8 / 6,0 / 8,2 4,8 / 7,1 / 8,9 3,1 / 3,9 / 4,9 2,1 / 5,5 / 7,1 Electric heater W 1.000 600 / 1.000 600 / 1.000 1.000 / 2.000 1.250 / 2.500 Energetic Class 2-pipes 5 FCEER B B B B A FCCOP A A A A A 4-pipes 5 FCCOP A A A A A FCEER B B B B A Hydraulic Gas Female threaded Cooling inch 1/2 1/2 1/2 1/2 1/2 Heating inch 1/2 1/2 1/2 1/2 1/2 Dimensions L x P x H (hors bac) mm 581 x 540 x 223 581 x 640 x 223 581 x 740 x 223 581 x 840 x 223 603 x 1.140 x 223 Weight kg 14 16 18 20 31 Water Terminals Performances based on: 1 According to Eurovent standard. Air: 27 C DB / 19 C WB, Water: 7 C/12 C. 2 According to Eurovent standard. Air: 20 C, same water flow as in cooling. 3 According to Eurovent standard. Air: 20 C, Water: 70 C/60 C. 4 Sound pressure considering an hypothetical installation and local attenuation of 21 db. 5 Energy class according to Eurovent. According to Eurovent standard 6/9 (thermal), 6/10 (airflow) and 8/12 (acoustics).
224 Water Terminals High static pressure ductable fan coil unit cooling and heating VH 3.5-33.9 kw 2.1-28.4 kw FActory Technical features Cooling Capacity from 2.1 to 28.4 kw Heating Capacity from 3.5 to 33.9 kw 6 sizes Versions 2-Pipes 2 pipes/2-wires 4-pipes Configuration Ceiling concealed Product Advantages Ease of installation and maintenance High static pressure avaiable up to 200 Pa Airflow rate up to 4.650 m³/h Very low operating acoustical levels in low speeds Selection of hydraulic and electric service side Configuration flexibility thanks to modular conception Various air intake configuration: rectangular or duct connections G3 filter as standard Compliant with ERP directive Main options and accessories Electrical heater with inserted heating rod 2-stage heater available with Aquanet control Selection of 3 speed Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted Large choice of control: Electro-mechanic, ModBus Communication interface board 2-way or 3-way ON/OFF valve G4 filter in option Ducted or rectangular plenum for air intake or dischage Fresh air intake Double skin insulation for ERP applications Auxiliary condensate drain pan Condensate drain pump Relay Fuse holder Individual packaging Valve Control IR control Drain pan Condensate drain pump Choice of ducted plenum for air intake or dischage Selection software Operating limit (to be confirmed following selection software issue) Cooling mode Minimum water temperature Maximum water temperature Maximum operating pressure Heating mode Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +60 C 15 bars 5 C/15% RH 32 C/70% RH
Water Terminals 225 Technical feature VH 07 15 18 21 24 27 Capacities - 2 PIPE - Nominal at 50 Pa Cooling 1 Total cooling capacity Sensible capacity Water flow W W l/h 4.560 / 5.500 / 5.810 3.270 / 4.150 / 4.470 785 / 950 / 1.000 7.080 / 11.930 / 13.990 5.220 / 9.610 / 11.890 1.220 / 2.055 / 2.410 7.860 / 14.430 / 17.560 5.590 / 10.840 / 13.660 1.354 / 2.486 / 3.025 8.290 / 16.130 / 20.180 5.780 / 11.690 / 14.940 1.430 / 2.778 / 3.476 15.170 / 17.240 / 19.720 11.110 / 12.790 / 14.890 2.613 / 2.970 / 3.400 16.780 / 19.400 / 22.640 11.830 / 13.780 / 16.240 2.890 / 3.342 / 3.900 Water pressure drop kpa 27 / 39 / 45 8 / 20 / 26 7 / 20 / 28 8 / 29 / 43 13 / 17 / 21 14 / 18 / 23 Heating 2 Heating capacity W Capacities - 2 PIPE - Nominal at 50 Pa Total cooling capacity W Sensible capacity W Cooling 1 Water flow l/h 5.370 / 7.060 / 7.630 4.180 / 5.020 / 5.300 2.990 / 3.740 / 4.020 720 / 865 / 913 8.010 / 14.870 / 18.370 6.560 / 10.460 / 11.990 4.940 / 8.840 / 10.810 1.130 / 1.800 / 2.065 8.730 / 17.050 / 21.620 6.950 / 11.570 / 13.500 5.190 / 9.540 / 11.810 1.200 / 1.993 / 2.325 9.010 / 18.110 / 23.110 7.930 / 14.760 / 18.100 5.630 / 10.970 / 13.860 1.366 / 2.540 / 3.118 18.590 / 21.620 / 25.310 14.050 / 15.790 / 17.810 10.630 / 12.160 / 14.040 2.420 / 2.720 / 3.068 19.070 / 22.290 / 26.370 15.220 / 17.300 / 19.790 11.110 / 12.800 / 14.910 2.622 / 2.980 / 3.410 Water pressure drop kpa 20 / 27 / 30 6 / 13 / 17 7 / 17 / 23 11 / 35 / 51 15 / 19 / 23 13 / 17 / 21 Heating capacity W 5.890 / 7.470 / 8.050 10.800 / 19.190 / 23.380 10.890 / 19.190 / 23.370 10.890 / 19.190 / 23.370 20.880 / 23.600 / 26.950 20.860 / 23.590 / 26.920 Heating 3 Water flow l/h 725 / 920 / 990 1.330 / 2.360 / 2.880 1.340 / 2.360 / 2.875 1.340 / 2.360 / 2.875 2.570 / 2.900 / 3.320 2.560 / 2.900 / 3.310 Water pressure drop kpa 9 / 14 / 16 39 / 109 / 156 24 / 66 / 95 24 / 66 / 95 74 / 93 / 118 46 / 58 / 75 Sound Levels (LS/MS/HS) Sound power level 4 db(a) 54 / 60 / 63 52 / 65 / 72 52 / 65 / 72 52 / 65 / 72 65 / 69 / 72 65 / 69 / 72 Sound pressure level 5 db(a) 53 / 59 / 61 52 / 64 / 71 52 / 64 / 71 52 / 64 / 71 63 / 67 / 71 63 / 67 / 71 Sound pressure level 5 db(a) 33 / 39 / 42 31 / 44 / 51 31 / 44 / 51 31 / 44 / 51 44 / 48 / 54 44 / 48 / 54 NR 5 db(a) 27 / 34 / 37 27 / 40 / 47 27 / 40 / 47 27 / 40 / 47 40 / 44 / 51 40 / 44 / 51 Fans (LS/MS/HS) Number 2 2 2 2 2 2 Static pressure kpa 30 / 50 / 70 15 / 50 / 90 15 / 50 / 90 15 / 50 / 90 35 / 50 / 75 35 / 50 / 75 Airflow at 50 Pa m³/h 703 / 977 / 1.125 960 / 2.112 / 2.830 960 / 2.112 / 2.830 960 / 2.112 / 2.830 2.040 / 2.413 / 2.925 2.040 / 2.413 / 2.925 Electrical Data (LS/MS/HS) Power supply V/Ph/Hz 230V / 1~ / 50Hz-60Hz Fan consumption STD W 132 / 182 / 222 180 / 421 / 675 180 / 421 / 675 180 / 421 / 675 420 / 530 / 870 420 / 530 / 870 Electrical heater (max) W 2.000 3.000 3.000 3.000 3.000 3.000 Water connections Gas Female threaded Gas male threaded Cooling coil 2-Pipes inches 1/2 1 1 1/4 1 1/4 1 1/4 1 1/4 Cooling coil 4-Pipes inches 1/2 1 1 1 1 1/4 1 1/4 Heating coil inches 1/2 3/4 3/4 3/4 3/4 3/4 Dimensions Rect-rect (LxWxH) Circ-Circ (LxWxH) mm mm 698 x 1.200 x 250 1.014 x 1.200 x 250 798 x 1.380 x 375 798 x 1.380 x 375 798 x 1.380 x 375 798 x 1.500 x 450 798 x 1.500 x 450 - - - - - Weight Rect-rect (Unit weight) kg 42 63 65 67 76 80 Circ-circ (Unit weight) kg 48 - - - - - Water Terminals 1 Air: 27 C DB/19 C WB, Water in: 7 C/12 C, 50 Pa external static pressure. 2 Air: 20 C, Water in: 50 C, same water flow as in cooling, 50 Pa external static pressure. 3 Air: 20 C, Water in: 70 C/60 C, 50 Pa external static pressure. 4 According Eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed. 5 Sound pressure considering an hypothetical installation and local attenuation of 21 db.
226 Water Terminals Water Terminal Control A full range dedicated to your needs Electro-Mechanical Control CMV TBMV TRM-VP TRM-FA System CMV TBMV TRM-VP TRM-FA 2 Pipes Reversible + valves > > > 2 Pipes / 2 Wires + valves > > 2 Pipes / 2 Wires reversible + valves 4 Pipes + valves > > > No valves > (Not recommended) > Action Change over Manual Manual Manual Fan speed selection Manual Manual Manual Fan action Continuous Fan 1 Cycling fan 2 Continuous fan 1 Cycling fan 2 Master/slaves 1 Continuous Fan: Fan runs continuously in cooling or heating mode. 2 Cycling Fan: Fan stops and starts with temperature demand.
Water Terminals 227 Electronic Control TAE 20 AQUASIMP AQUANET RCL Wired remote control Advanced Control Performance Temperature sensor included Display of temperature Selection of the speed LED - On/Off & Default or RC7 Infra remote control Advanced Control Performance Temperature sensor included Display of temperature Selection of the speed LED - On/Off & Default Water Terminals µbms Carte NIU TAE 20 AQUASiMP AQUANET > > > > > > > > > > > > > Automatic Manual or automatic Manual or automatic Manual Manual Manual or automatic Continuous 1 or cycling fan 2 Continuous 1 or cycling fan 2 Up to 10 slaves with no additional interface Continuous or cycling fan 2 Up to 15 slaves with only one control device Managing up to 15 different zone, with a maximum of 80 units. Programming and control of the temperature indivdualized by zone Weekly programmation 2 daily ranges configurable by area Carte e-niu - MODBUS This card allow the connection to a Modbus communication protocol. The NIU card gives an individual adress to each fan coil inside the communication bus system. Manual programmation with DIP Switch
Water Source Heat Pump SYSEFTYS 2.1-2.7 kw 2.7-3.2 kw 407C SYSCWar 1.9-2.7 kw 2.4-3.2 kw 407C Scroll SYSHRW 5.3-30 kw 5.8-38 kw 407C
Water Source Heat Pump 229 Selection guide Water Source Heat Pump Product Range Capacity Acoustic Flow rate Pressure Fan Size (LxHxP) mm SYSEFTYS EFTYS 2000 2 kw EFTYS 2500 2.4 kw EFTYS 3000 3 kw NR 32 at MS NR 34 at MS NR 37 at MS 452 m³/h at HS 503 m³/h at HS 605 m³/h at HS 50Pa at HS EC 900x530x239 900x530x239 900x530x239 SYSCWAR CWAR 07 CWAR09 CWAR12 1.9 kw 2.1 kw 2.7 kw NR 37 at MS NR 38 at MS NR 40 at MS 400 m³/h at HS 460 m³/h at HS 510 m³/h at HS 0 Pa EC * 1.138x251x821 1.138x251x821 1.138x251x821 HRW019 5.3 kw NR 42 at MS 1.250 m³/h at HS >50 Pa at HS 900x600x439 HRW027 7.4 kw NR 44 at MS 1.185 m³/h at HS >50 Pa at HS 1.050x660x460 HRW030 8.7 kw NR 43 at MS 1.490 m³/h at HS >100 Pa at HS 1.050x660x460 HRW036 10.1 kw NR 44 at MS 1.580 m³/h at HS >100 Pa at HS 1.250x705x513 SYSHRW HRW042 HRW048 11.4 kw 12.9 kw NR 44 at MS NR 47 at MS 2.040 m³/h at HS 2.750 m³/h at HS >100 Pa at HS >100 Pa at HS 1.250x705x513 1.250x705x513 HRW060 14.3 kw NR 47 at MS 2.840 m³/h at HS >100 Pa at HS 1.250x705x513 HRW072 17.1 kw NR 48 at MS 3.570 m³/h at HS >100 Pa at HS 1.250x705x513 HRW096 21.7 kw NR 56 at HS 4.700 m³/h at HS >100 Pa at HS 1.680x955x770 HRW120 30 kw NR 57 at HS 5.600 m³/h at HS >200 Pa at HS 1.680x955x770 Ideal solution for refurbishment, and R22 units replacement, as well as for new applications. TECHNOLOGY AND RELIABILITY Stantard protective devices: Flow switch/pressostat on hydraulic circuit LP pressure switch Fuse holder Water Source Heat Pump Advance scroll technology CLOSE CONTROL REFRIGERANT OZONE FRIENDLY Rotary or scroll springs compressor
230 Water Source Heat Pump STORM 2 Electronic control system Product Avantages Measurement of the room air temperature Anti-short cycle to protect the compressor Variable sequential start-up function avoiding a power surge Emergency shut-down / stand-by / night setback Automatic HP reset pressure and/or lack of water flowrate Automatic BP reset pressure Défaut ipsotherme moteur ventilateur Anti-freeze safety function Low temperature limit in cooling/heating mode High temperature limit in cooling/heating mode Antifreeze default in cooling mode Managing of motorized water valves Chaining Modbus Main functions Digital display On/Off Selection of the working mode Display of the room temperature Display of the room temperature Selection of the speed of the fan A keypad lock function is also available Display LED which shows the operating status of the water source heat pump Master/slaves control up to 10 units with only one remote control Remote control RCL
Water Source Heat Pump 231 Advanced functianilities modbus communication as a standard 0-10 V output to control EC motor, 100% modulated Fault reports of eight different possible machine faults Four different operating modes for water source heat pumps by selecting the following systems: Thermodynamic cooling and heating operation (RC). Thermodynamic cooling and heating operation or heating operation with an additional electric heater (SH). Thermodynamic cooling operation and electrical heating operation (RH). Thermodynamic cooling operation only (ST). Main functions Display LED which shows the operating Advanced Control Performances Temperature sensor included Display of temperature Selection of the speed LED - On/Off & Default Infrared remote control RC07 Water Source Heat Pump Main functions Managing up to 15 different zone, with a maximum of 80 units Programming and control of the temperature indivdualized by zone Weekly programmation 2 daily ranges configurable by area CLOSE CONTROL Mini central supervisor µbms
232 Water Source Heat Pump Water source heat pump SYSEFTYS 1.9-3.0 kw 407C 2.7-3.6 kw HOTEL OFFICES Technical features Cooling Capacity from 1.9 to 3.0 kw Heating Capacity from 2.7 to 3.6 kw Sizes: 3 models, 1 casings Versions RC: cooling and heating ST: cooling only SH: cooling and heating or electrical heating RH: cooling and electrical heating Configuration Horizontal concealed installation Product Advantages A coaxial heat exchanger robust in presence of loaded water An extended working range +9 to +48 High energetical performances, with EC motor and high COP/ EER Coil at the oultet to avoid the installation of a siphon Stand-alone STORM2 electronic control with ModBus Communication Easy access to components through wide removable panels Many aeraulic and hydraulic configuration to easily replace the unit alread on site Extended working range through coaxial heat exchanger Acoustical insulation and compressor isolated and mounted on spring to an optimal acoustical comfort Anti-corrosion treated drain pan Low height < 250 mm Main options and accessories G2/ M1 filter Electrical heater Quick connector General alarm dry contact Circuit breaker Front or lateral ducted plenum for air discharge Fresh air intake Individual packaging Room sensor Flow switch for low waterflow protection Motorized water valve µbms mini-supervision station RCL remote control Operating limit (to be confirmed following selection software issue) SYSEFTYS Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 18 C Max 45 C Min 9 C Max 32 C Min 21 C db / 15 C wb Max 32 C db / 23 C wb Min 15 C Max 25 C 31 bars
Water Source Heat Pump 233 Technical feature SYSEFTYS FT20 FT25 FT30 Total cooling capacity 1 W 2.057 2.405 2.983 Sensible cooling capacity 1 W 1.686 1.983 2.346 Heating capacity 1 W 2.706 2.997 3.558 Performances COP 1 4,12 4,17 4,3 EER 1 3,88 4,13 3,85 Fans Nominal Airflow m³/h 452 503 605 Air filter Number / Efficiency 1 / G2 1 / G2 1 / G2 Air filter Dimensions / Thickness mm 225 x 365 / 20 225 x 365 / 20 225 x 365 / 20 Water Connections Nominal water flow l/h 418 457 623 Cutoff water flow vs nominal water flow 2 % 43 39 29 WPD at nominal water flow kpa 11 13 23 WPD at nominal water flow with valve kpa 27 30 44 Hydraulic connections inches Male type ISO G 1/2 INT Condensate outlet - external ø mm 16 16 16 Electical Data Power supply V / Ph / Hz 230V / 1~ / 50Hz 230V / 1~ / 50Hz 230V / 1~ / 50Hz Power input - cooling mode 3 W 595 648 879 Power input - heating mode 3 W 722 785 932 Electrical heater 4 W 1.200 1.600 2.000 Fan maximum current (ESP=0Pa) A 0,85 0,85 1,4 Compressor nominal current A 2,8 3,0 4,0 Compressor starting current A 16 16 18,9 Sound levels Sound power level intake+rad 5 db(a) 55/57/59 56/58/60 56/58/62 Sound power level Discharge 5 db(a) 53/55/56 54/56/58 58/61/65 Sound pressure level 6 db(a) 34/36/38 35/37/39 37/40/44 NR 5 db(a) 30/32/34 31/34/36 34/37/42 Dimensions L x W x H mm 900x530x 240 900x530x240 900x530x240 Weight Unit weight kg 48 48 48 Water Source Heat Pump CLOSE CONTROL 1 Performances given at nominal conditions. Cooling mode: Tair=27 C, Twater=30 C & Heating mode: Tair=20 C, Twater=20 C. 2 Protection by flow switch (accessory). 3 Absorbed power (compressor + fan) at nominal conditions. 4 Electric heating coil is an optional feature available on SH & RH versions. 5 Sound power level considering 50Pa available static pressure in high speed, in-line unit configuration with filter. 6 Sound pressure considering an hypothetical installation and local attenuation of 21 db.
234 Water Source Heat Pump Water source heat pump SYSHRW 5.3-3.0 kw 407C 5.8-38.1 kw Scroll SHOPPING Technical features Cooling Capacity from 5.8 to 38.1 kw Heating Capacity from 5.3 to 3.0 kw Refregirant: R407C Sizes: 10 models, 4 casings Versions RC: cooling and heating ST: cooling only SH: cooling and heating or elctrical heating RH: cooling and electric heating Configuration Horizontal concealed installation Product Advantages A coaxial heat exchanger robust in presence of loaded water High efficiency horizontal units with high COP 5 optimized compact casing Easy access to components through wide removable panels In-line or perpenducular air blowing Brazed stainless steelplate heat exchanger for improved efficiency Flow switch for antifreeze protection as standard Bi-flow thermostatic expansion valve as standard Anti-corrosion treated drain pan Float-type safety system to protect agains condensate overflow Stand-alone STORM electronic control with RCL remote control Main options and accessories G2/ M1 filter µbms-2 mini-supervision station ModBus Communication interface board 3-speed direct drive fan motor (up to 17 kw) or belt-driven fan with variable pitch pulley (above 17 kw) G2 filter as standard, G3 in option * 15 mm thick thermal and acoustical insulation M1-class fire insulation Electrical heater Motorized water valve General alarm dry contact Disconnect switch * Front or lateral ducted plenum for air intake * Fresh air intake Individual packaging * Room sensor * Available on some models. Operating limit (to be confirmed following selection software issue) SYSHRW 19-72 96-120 Water inlet temperature Cooling Min 18 C 20 C Max 44 C 48 C Heating Min 13 C Max 34 C Return Air temperature Cooling Min 21 C BS/15 C BH Max 38 C BS/28 C BH 38 C BS/28 C BH Heating Min 15 C Max 27 C 25 C Maximum operating pressure 31 bars
Water Source Heat Pump 235 Technical feature SYSHRW 019 027 030 036 042 048 060 072 Total cooling capacity W 5.278 7.419 8.691 10.138 11.366 12.965 14.344 17.174 Sensible cooling capacity W 4.257 5.824 6.315 7.278 8.849 10.051 10.988 13.536 Heating capacity W 5.826 8.342 9.759 11.036 14.422 14.904 16.147 21.500 Fans Nominal Airflow m³/h 1.250 1.185 1.490 1.580 2.040 2.750 2.840 3.570 Motor power W 145 145 210 245 320 550 550 550 Fan speeds Nbr 3 3 3 3 3 3 3 3 Air filter Number/Efficiency 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 Air filter Dimensions/Thickness mm 365x 300/25 365x 300/25 385x 350/25 385x 350/25 450x 440/25 450x 440/25 450x 440/25 450x 440/25 Water Connections Plate heat exchanger Nbr 1 1 1 1 1 1 1 1 Nominal water flow 1 l/h 920 1.540 1.764 2.030 2.592 2.822 3.348 3.924 Cutoff water flow vs nominal water flow % 50 50 47 45 39 38 35 41 WPD at nominal water flow 1 kpa 13 17 23 25 33 34 40 61 WPD at nominal water flow with valve 6 kpa 16 23 33 39 55 60 77 112 Hydraulic connections inches ISO G 3/4 INT Condensate outlet (external ø) mm 19 19 19 19 19 19 19 19 Refrigerant circuit Number of circuit 1 1 1 1 1 1 1 1 Compressor type Rotatif Scroll Scroll Scroll Scroll Scroll Scroll Scroll Electical Data Power supply V/Ph/Hz 230V / 1~ / 50Hz 400V / 3~N / 50Hz Power input (cooling mode) 4 W 1.557 2.118 2.658 3.044 3.584 4.200 4.989 6.280 Power input (heating mode) 4 W 1.611 2.332 2.983 3.460 3.920 4.300 5.150 7.347 Electrical heater W 2.250 3.750 3.750 4.500 5.500 6.500 7.500 9.000 Fan maximum current (ESP=0Pa) 7 A 1,5 1,5 2,6 2,4 3,55 4,7 4,7 6,9 Compressor nominal current A 6,6 3,7 4,5 5,4 5,7 7 7,5 10,6 Compressor starting current A 33 32 40 46 51,5 54 65,5 101 Sound levels Sound power level 8 db(a) 51/54/58 54/56/57 53/54/57 53/56/58 54/56/58 55/59/63 55/59/63 57/60/63 Sound pressure level 9 db(a) 44/47/51 47/49/50 46/47/50 46/49/51 47/49/51 48/52/56 48/52/56 50/53/56 NR 9 db(a) 39/42/46 42/44/45 41/43/45 41/44/46 42/44/46 43/47/49 43/47/49 45/48/51 Dimensions LxWxH mm 900 x 600 x 439 1.050 x 660 x 460 1.050 x 660 x 460 1.050 x 660 x 460 1.250 x 705 x 513 1.250 x 705 x 513 1.250 x 705 x 513 1.250 x 705 x 513 Weight Unit weight kg 80 100 100 112 133 140 144 149 Water Source Heat Pump CLOSE CONTROL 1 Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. 2 Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. 3 Protection by differential pressure switch on units HRW 019 to 120. 4 Absorbed power (compressor + fan) at nominal conditions. 5 Electric heating coil is an optional feature available on SH & RH versions. 6 Total water pressure drop with optional water valve fitted. 7 fan power supply: 230V/1Ph for HRW 072, 400V/3Ph for HRW 096 & 120. 8 Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. 9 Sound pressure considering an hypothetical installation and local attenuation of 7 db. * Only with return air plenum. ** one RCL is delivery with unit as standard with size 19 to 120.
236 Water Source Heat Pump Technical features SYSHRW 096 120 Total cooling capacity W 21.743 29.951 Sensible cooling capacity W 17.986 24.413 Heating capacity W 26.637 38.109 Fans Nominal Airflow m³/h 4.700 5.600 Motor power W 1.100 1.500 Fan speeds Nbr - - Air filter Number/Efficiency 2/G2 2/G2 Air filter Dimensions/Thickness mm 620x650/25 620x650/25 Water Connections Plate heat exchanger Nbr 1 1 Nominal water flow 1 l/h 4.860 6.408 Cutoff water flow vs nominal water flow % 44 30 WPD at nominal water flow 1 kpa 55 80,5 WPD at nominal water flow with valve 6 kpa 133 250 Hydraulic connections inches ISO G 1 1/4 Condensate outlet (external ø) mm 22 22 Refrigerant Circuit Number of circuit 1 1 Compressor type Scroll Scroll Electrical Data Power supply V/Ph/Hz 400V / 3~N / 50Hz 400V / 3~N / 50Hz Power input (cooling mode) 4 W 6.317 8.547 Power input (heating mode) 4 W 7.895 10.224 Electrical heater W 13.000 16.000 Fan maximum current (ESP=0Pa) 7 A 2,5 4,1 Compressor nominal current A 11,4 14,8 Compressor starting current A 111 118 Sound Levels Sound power level 8 db(a) 68 69 Sound pressure level 9 db(a) 61 62 NR 9 db(a) 56 57 Dimensions LxWxH mm 1.680 x 955 x 770 1.680 x 955 x 770 Weight Unit weight kg 253 262 1 Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. 2 Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. 3 Protection by differential pressure switch on units HRW 019 to 120. 4 Absorbed power (compressor + fan) at nominal conditions. 5 Electric heating coil is an optional feature available on SH & RH versions. 6 Total water pressure drop with optional water valve fitted. 7 Fan power supply: 230V/1Ph for HRW 019 to 072, 400V/3Ph for HRW 096 & 120. 8 Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. 9 Sound pressure considering an hypothetical installation and local attenuation of 7 db.
Water Source Heat Pump CLOSE CONTROL
238 Water Source Heat Pump Water source heat pump cooling and heating SYSCWAR 1.9-2.7 kw 407C 2.4-3.2 kw Scroll HOTEL OFFICES Technical features Cooling Capacity from 1.9 to 2.7 kw Heating Capacity from 2.4 to 3.2 kw Refregirant: R407C Sizes: 3 models Versions RC: cooling and heating CAR: standard with cabinet CARB: low height with cabinet nu: standard without cabinet NUB: low height without cabinet Configuration Vertical console cabinet Vertical concealed without cabinet Product Advantages A coaxial heat exchanger robust in presence of loaded water control High efficiency vertical units with high COP Harmonuous and aesthetic RAL9010 painted cabinet design Design and elaborate finish enabling harmonious integration Low consumption EC fan motor or 3-speed AC fan motor Stand-alone STORM electronic control with RCL remote control Brazed stainless steelplate heat exchanger for improved efficiency Easy access to components through front panel Ease of installation through selection of service side Direct access to Schrader valves (HP & BP) Flow switch for antifreeze protection as standard Anti-corrosion treated drain pan Main options G2/ M1 filter µbms mini-supervision station ModBus Communication interface board L/R Lateral, back or bottom hydrualic connections L/R lateral electrical connection G2 filter 15 mm thick thermal and acoustical insulation LONWorks control Bottom return air with feet or front air intake HP & BP pressure switches General alarm dry contact Disconnect switch Thermostat Operating limit (to be confirmed following selection software issue) SYSCWAR Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 23 C Max 42 C Min 12 C Max 34 C Min 21 C BS/15 C BH Max 32 C BS/23 C BH Min 15 C Max 27 C 3 bars
Water Source Heat Pump 239 Technical feature SYSCWAR 07 09 12 Total cooling capacity W 1.942 2.136 2.743 Sensible cooling capacity W 1.526 1.775 2.340 Heating capacity W 2.431 2.542 3.156 Ventilation Nominal Airflow m³/h 400 460 616 Motor power W 75 75 75 Fan speeds Nbr 3 3 3 Air filter Number/Efficiency 1/G2 Air filter (Front) Dimensions/Thickness mm 660x205/6 Air filter (Bottom) Dimensions/Thickness mm 595x187/6 Water Connections Plate heat exchanger Nbr 1 Nominal water flow 1 l/h 428 479 0,171 Cutoff water flow vs nominal water flow % 44 40 31 WPD at nominal water flow 1 kpa 5 3,4 12 Hydraulic connections inches ISO G 1/2 INT Condensate outlet (external ø) mm 15x20 Refrigerant Circuit Number of circuit 1 Compressor type Rotatif Electrical Data Power supply V/Ph/Hz 230V / 1~ / 50Hz Power input (cooling mode) 4 W 598 647 892 Power input (heating mode) 4 W 710 720 954 Fan maximum current A 0,2 0,25 0,3 Compressor nominal current A 2,8 3 4 Compressor starting current A 16 16 18,9 Sound Levels (LS/MS/HS) Sound power level db(a) 49/50/51 50/51/53 51/53/54 Sound pressure level 5 db(a) 41/42/43 42/43/45 43/45/46 NR 5 db(a) 36/37/38 37/38/40 38/40/41 Dimensions (LxWxH) Console (STD) 6 mm 1.138 x 251 x 821 Concealed (STD) 6 mm 1.086 x 229 x 769 Weight Console (STD) kg 70 73 75 Concealed (STD) kg 55 58 60 Water Source Heat Pump CLOSE CONTROL 1 Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. 2 Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. 3 Protection by flow switch on units CW-AR 007, 009 & 012. 4 Absorbed power (compressor + fan) at nominal conditions. 5 Sound pressure considering a local of 100 m 3, a reverberation time of 0,5 sec and a distance of 1 m. 6 Feet included.
Roof Top HAN 9.8-31 kw 9.6-30.5 kw 410A Scroll Rooftair 30-108 kw 33-108 kw 410A Scroll
Rooftop 241 Selection guide Rooftop Product Range Capacity Flow rate Pressure Acoustic Power HAN RoofT@ir HAN 13 HAN 15 HAN 17 HAN 19 HAN 25 HAN 31 RTL/RTH 30 RTL/RTH 40 RTL/RTH 50 RTL/RTH 60 RTL/RTH 70 RTL/RTH 80 13.0 kw 14.5 kw 16.8 kw 18.9 kw 25.4 kw 31.0 kw 32.5 kw 41.5 kw 50.9 kw 59.8 kw 67.7 kw 84.9 kw 2.640 m 3 /h 2.940 m 3 /h 3.190 m 3 /h 3.860 m 3 /h 4.780 m 3 /h 5.530 m 3 /h 5.500 m 3 /h 7.650 m 3 /h 9.200 m 3 /h 11.500 m 3 /h 12.500 m 3 /h 16.500 m 3 /h RTL/RTH 100 96.6 kw 18.650 m 3 /h RTL/RTH 110 108.4 kw 20.000 m 3 /h 100 Pa 170 Pa 160 Pa 210 Pa 240 Pa 250Pa 400 Pa 400 Pa 400 Pa 450 Pa 450 Pa 500 Pa 500 Pa 500 Pa 75 db(a) 75 db(a) 75 db(a) 82 db(a) 82,7 db(a) 82,7 db(a) 84,5 db(a) 84,5 db(a) 88,3 db(a) 82,6 db(a) 83,3 db(a) 83,8 db(a) 85,8 db(a) 87,1 db(a) Size (LxHxP) mm 1.345 x 95 x 1.320 1.345 x 95 x 1.320 1.345 x 95 x 1.320 1.345 x 95 x 1.320 1.420 x 1.320 x 1.445 1.420 x 1.320 x 1.445 2.484 x 1.450 x 1.877 2.484 x 1.450 x 1.877 2.484 x 1.450 x 1.877 3.400 x 1.771 x 2.227 3.400 x 1.771 x 2.227 3.400 x 1.771 x 2.227 3.400 x 1.813 x 2.227 3.400 x 1.813 x 2.227 Roof Top
242 Rooftop Rooftop unit cooling and heating HAN 9.8-31.0 kw 410A 9.6-30.5 kw Scroll Technical features Cooling Capacity from 9.8 to 31 kw Heating Capacity from 9.6 to 30.5 kw Refrigerant: R410A Sizes: 6 Product Advantages A coaxial heat exchanger robust in presence of loade Weather resistant casing with external panels and drain pan coated with powder-based epoxy paint colour RAL 7040 Base rail with forklift slots to facilitate transportation and handling. Technical compartment independent from airstreams allowing service works to be performed without disturbing the unit operation High EER and environmentally freindly refrigerant R410A with zero ODP (Ozone Depleting Potentila) High efficiency scroll compressor with crankcase heater Condenser coils with hydrophilic coated fins to improve removal of water droplets during defrost cycles Standard microprocessor-based control by CAC controller Main options and accessories G2/ M1 filter Factory-fitted low ambient temperature control to ensure cooling operation down to -10 C outdoor temperature (All-season) Synthetic air filter Electric heater Programmable controlller RCW2 to control up to 15 units with independent set points and programming Operating limit (for standard unit) (to be confirmed following selection software issue) Cooling mode Minimum indoor air temperature 21 C DB/15 C WB Maximum indoor air temperature 32 C DB/23 C WB Minimum outdoor air temperature/with all-season kit 15 C DB/-10 C Maximum outdoor air temperature 50 C DB Heating mode Maximum indoor air temperature 27 C DB Minimum outdoor air temperature -10 C Maximum outdoor air temperature 24 C (16 C for HAN 25)
Rooftop 243 Technical feature HAN HAN 13 HAN 15 HAN 17 HAN 19 HAN 25 HAN 31 Cooling capacity kw 13,0 14,5 16,8 18,9 25,4 31,0 Cooling Power input kw 4,5 4,9 6,0 6,5 8,3 10,0 EER 2,88 2,95 2,8 2,9 2,95 3,1 Heating capacity kw 12,1 14,2 15,8 19,0 24,2 30,5 Heating Power input kw 4,3 4,5 5,7 6,0 8,8 9,5 COP 2,8 3,1 2,7 3,1 2,75 3,2 Compressors Scroll Scroll Scroll Scroll Scroll Scroll Number 1 1 1 1 1 1 Ventilation Available static pressure Pa 100 170 160 210 240 250 Airflow Indoor fan m³/h 2,640 2,940 3,190 3,860 4,780 5,530 Outdoor fan m³/h 9,000 9,000 9,000 9,000 12,000 12,000 Sound Levels * Lw Outdoor (Configuration A) db(a) 80,7 79,3 79,3 83,1 84,9 86,4 Sound pressure Lp calculated at 1 m db(a) 76,9 75,5 75,5 79,3 81,1 82,6 Sound pressure Lp calculated at 5 m db(a) 74,8 73,4 73,4 77,2 79,0 80,5 Lw Indoor (Configuration B) db(a) 77,1 75,0 75,0 72,7 78,2 82,7 Sound pressure Lp calculated at 1 m db(a) 73,3 71,2 71,2 68,9 74,4 78,9 Sound pressure Lp calculated at 5 m db(a) 71,2 69,1 69,1 66,8 72,3 76,8 Power Supply Power supply 400V/3N-/50Hz Fuse rating am A 16 20 20 25 32 32 Dimensions LxWxH mm 1,320 x 1,345 x 905 1,420 x 1,445 x 1,320 Weight Unit weight kg 219 223 223 243 320 343 Roof Top * Pressure sound level calculated according the following: Q 4 Lp = Lw + 10 Log ( + ) 4πD ² A Factor Q 2 2 = free field, 4 = against wall, 8 = on corner V 100 Room volume in m 3 (on example, V = 100 m 3 ) Lg = 10 T 1 Reverberation time in s lg = 10 A 16 A = 0,16 x (V/T) Ht = 2,5 D Distance in m
244 Rooftop Rooftair Rooftop unit cooling and heating RTL/RTH 30-110 32.5-108 kw 410A 33.3-108 kw Scroll Technical features Cooling Capacity from 32.5 to 108 kw Heating Capacity from 33.3 to 108 kw Refrigerant: R410A Airflow range: from 5.500 to 20.000 m³/h 8 sizes Insulation: 25 mm Glasswool Product Advantages Technical compartments for RTL/RTH 100-110 Weatherproof technical compartment independent from the airflow with a natural ventilation of the electrical board to stop overheating in summer. All electric cables and wires are protected Refrigeration system: R410A benefits: best heat transfer and environmental friendly refrigerant with zero ODP (Ozone Depleting Potential). Stable composition compared to R407C (2 refrigerant mixture instead of 3 with R407C). Temperature glide less than 0,2 K during evaporation, smaller liquid line pipe and lower refrigerant charge. Refrigeration circuit: cooling only or heat pump version designed to satisfy comfort and commercial applications with scroll compressors for higher efficiency with better resistance to liquid return and less vibration. Crankcase heater on each compressor to eliminate refrigerant migration and improve start up in winter. Tandem compressors on 1-circuit and single compressor on dualcircuits provide 2-stage cooling/ heating capacity. Refrigerant brazing, fittings, and indoor coil headers are assembled in one technical compartment to ease service without disturbing unit operation Main options and accessories Filters: Universal cells dimensions mounted on sliding rail for easy service 2 options of flat filters: G4 filter & High efficiency filter G4+F6 compliant with EN 779 Factory fitted clogged filter switch wired to the IATC (option) F-damper economizer (R1 and R2 configurations): economizer allows using the greatest obtainable quantity of outdoor air energy to minimize compressor consumption Economizer is equipped with 2 counteracting dampers linked together to one proportional actuator wired to IATC Adjustable minimum position of outdoor air damper to control hygienic ventilation. The economizer is equipped with sensors wired to the IATC According to control type, 3 combinations of sensors are available: Sensible, Enthalpy, or, Air quality contro. Additional options: Standard or ERP conform Roof Curb Antivibration mounts, Smoke detector & Double skin Bi-flow devices (expansion device, filter-dryer, sight glass) are used on each circuit Outdoor coils designed for low air resistance to reduce axial fan power consumption and noise level Hydrophilic blue fins provided on outdoor coils (heat pump version only) for better removal of water droplets on defrost cycle Holes in the unit floor under the outdoor coils to drain defrost and rain water beyond the roof curb to the roof Indoor coil (blue fins) allows for commercial or industrial applications with higher dehumidification rate Extractible drain pan under indoor coil, to allow for hygienic cleaning Optional low ambient operation kit ensures cooling operation down to -10 C outdoor temperature Optional electric heater CH1 & CH2, and, hot water coil Operating limit (for standard unit) (to be confirmed following selection software issue) Cooling mode Maximum outdoor air temperature 46 C Minimum outdoor air temperature 6 20 C Heating mode Maximum outdoor air temperature 21 C Minimum outdoor air temperature -10 C
Rooftop 245 Technical feature RTL/RTH 30 40 50 60 70 80 100 110 Cooling capacity 1 kw 32,5 41,5 50,9 59,8 67,7 84,9 96,6 108,4 Power input kw 10,4 12,8 16 18,4 20,9 26 30,9 36,5 EER 2 3,12 3,3 3,2 3,3 3,2 3,3 3,1 3 Power supply 400V - 3ph + N - 50Hz Heat Pump Version Cooling capacity 1 kw 32 41 48,6 59 66 83,4 94,8 106,1 Power input kw 10,4 12,8 16 18,4 20,9 26 30,9 36,5 EER (Cooling mode) 2 3,1 3,2 3 3,2 3,2 3,2 3,1 2,9 Heating capacity 3 kw 33,3 42,9 50,2 58,2 66,5 84 96 108 Power input kw 9,5 12,2 15,1 17,8 20,3 24,1 28,5 33,7 COP (Heating mode) 4 3,5 3,5 3,3 3,3 3,3 3,5 3,4 3,2 Refrigerant HFC 410A Number of circuits 1 1 1 2 2 2 2 2 Compressors Number of compressors 2 2 2 2 2 2 2 2 Assembly type Tandem Tandem Tandem Single Single Single Single Single Capacity step % 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 Indoor coil Copper tubes & aluminium fins Number of rows 3 3 3 3 3 3 4 4 Indoor fan (standard) Forward curved centrifugal Quantity/Model 1 1/AT 15-15S 1/AT 15-15S 1/ADH 450 1/ADH 450 1/ADH 500 1/ADH 500 1/ADH 500 Air flow m³/h 5.500 7.650 9.200 11.500 12.500 16.500 18.650 20.000 Nominal static pressure Pa 250 250 250 300 300 350 350 350 Motor power kw 1,5 1,5 2,5 5,5 5,5 7,5 7,5 7,5 (optional) Back curved Forward curved centrifugal Backward curved centrifugal Quantity/Model 1 1/AT 15-15S 1/AT 15-15S 1/RDH 450 1/RDH 450 1/RDH 500 1/RDH 500 1/RDH 500 Air flow m³/h 5.500 7.650 9.200 11.500 12.500 16.500 18.650 20.000 Nominal static pressure Pa 400 400 400 450 450 500 500 500 Motor power kw 2,2 4 5,5 5,5 5,5 7,5 7,5 7,5 Outdoor coil / Number of rows Copper tubes & aluminium fins / 2 Outdoor fans Propeller Diameter mm 610 610 610 610 610 610 800 800 Quantity 2 2 2 4 4 4 2 2 Fan rotational speed rpm 850 850 850 850 850 850 670 670 Nominal air flow m³/h 16.000 16.000 16.000 32.000 32.000 32.000 34.000 34.000 Total motor power kw 1,14 1,14 1,14 2,28 2,28 2,28 2 2 Synthetic Flat Filters (Optional) Number of filters 4 4 4 9 9 9 9 9 Efficiency/Filter class > 90%/G4 Universal cells Synthetic Flat Filters (Optional) Number of filters 4 4 4 9 9 9 9 9 Efficiency/Filter class > 90%/F6 Universal cells Casing Min, casing thickness mm 1 1 1 1 1 1 1 1 Painting type / RAL Powder coating / 9001 Fire resistance class M0 Dimensions & Weight Length mm 2.484 2.484 2.484 3.400 3.400 3.400 3.400 3.400 Width mm 1.877 1.877 1.877 2.227 2.227 2.227 2.227 2.227 Height mm 1.450 1.450 1.450 1.771 1.771 1.771 1.813 1.813 Weight 5 kg 600 650 700 1.100 1.150 1.200 1.300 1.350 Roof Top 1 Cooling capacity with Eurovent conditions: 35 C dry bulb outdoor, 27 C dry bulb/19 C wet bulb entering indoor. 2 EER = Cooling capacity/effective power input. 3 Heating capacity with Eurovent conditions: 7 C dry bulb/6 C wet bulb outdoor, 20 C entering indoor. 4 COP = Heating capacity/power input. 5 Without option. 6 For lower outdoor air temperature (-10 C), in cooling mode, use low ambient kit (optional).
Close control CW 21-152 5-150 kw Chiller water CD 031-71 10-22.1 kw 407C Scroll MD 061-202 18.3-64.1 kw 407C Scroll CG 010-055 9.4-65 kw 407C
Close Control 247 Chilled Water Close control CW 5-152 5.0-153.0 kw Chilled water Technical features UNDER version down air flow OVER version air up flow EC fans, backward curved blade Advanced microprocessor control interface user and semi-graphic LCD display EU4 filters Frontal access for maintenance Accessories and options Adjustable base frame Air delivery plenum Centrifugal fans, backward curved blades Double pannels (sandwich) Electric post-heating coil EU5 or EU7 filters Humidification/dehumidification option LAN connection or remote monitoring systems Rear return air (only for up flow version) Technical feature CW 5-41 5 8 10 21 31 41 Total cooling capacity kw 5,7 7,7 9,8 15,1 25,8 35,5 Sensibile cooling capacity kw 4,7 6,2 8 13,8 22,6 30,2 Nominal air flow m 3 /s 0,35 0,55 0,54 1,11 1,45 1,81 Sound pressure level * (up/down flow) db(a) 55.5/51.5 55.9/51.9 55.9/51.9 54.5/50.5 56/52 58.5/54.5 Dimensions Lenght mm 650 650 650 650 840 1.238 Width mm 450 450 450 650 650 650 Height mm 1.970 1.970 1.970 1.970 1.970 1.970 CW 51-152 51 61 82 102 112 152 Total cooling capacity kw 49,8 57,8 83 94,8 110,8 152,8 Sensibile cooling capacity kw 42,7 51,1 67,9 78 95,8 128,9 Nominal air flow m 3 /s 2,78 3,33 4,86 5,56 6,94 10 Sound pressure level * (up/down flow) db(a) 59/55 61.1/57.5 65/61 63/59 64/60 67/63 Dimensions Lenght mm 1.428 1.618 1.885 1.885 2.265 2.853 Width mm 650 650 860 860 860 860 Height mm 1.970 1.970 1.980 1.980 1.980 1.980 Close control * Sound pressure level measured at 2 m from the machine and at 1 m from the ground in free field conditions.
248 Close Control Close control with remote condenser CD 031-071 10-22.1 kw 407C Scroll Technical features UNDER version air down flow OVER version air up flow Centrifugal fan double inlet directely coupled Scroll compressors Advanced microprocessor control interface user and semi-graphic LCD display EU4 filters Frontal access for maintenance Accessories and options Adjustable base frame Air delivery plenum Double pannels (sandwich) Electric post-heating coil EU5 or EU7 filters Humidification/dehumidification option LAN connection or remote monitoring systems Rear return air (only for up flow version) Technical feature CD 031-071 031 041 051 061 071 Total cooling capacity kw 10 12,8 15,3 20,5 22,1 Sensibile cooling capacity kw 9,3 12 13,9 19,3 20,5 Nominal air flow m 3 /s 0,75 1,11 1,11 1,67 1,67 Sound pressure level * (up/down flow) db(a) 52/48 55/51 55/51 55/51 56/52 Dimensions Lenght mm 650 840 840 1.238 1.238 Width mm 650 650 650 650 650 Height mm 1.970 1.970 1.970 1.970 1.970 * Sound pressure level measured at 2 m from the machine and at 1 m from the ground in free field conditions.
Close Control 249 Close control with remote condenser MD 061-202 18.3-64.1 kw 407C Scroll Technical features UNDER version down air flow OVER version air up flow EC centrifugal fans, backward curved blades Advanced microprocessor control interface user and semi-graphic LCD display EU4 filters Frontal access for maintenance Accessories and options Adjustable base frame Air delivery plenum Double pannels (sandwich) Electric post-heating coil EU5 or EU7 filters Humidification/dehumidification option LAN connection or remote monitoring systems Rear return air (only for up flow version) Technical feature MD 061-101 061 071 091 101 Total cooling capacity kw 18,3 24,3 28,4 32,9 Sensibile cooling capacity kw 17,4 23 26,3 30,5 Nominal air flow m 3 /s 1,39 2,08 2,08 2,5 Sound pressure level * (up/down Flow) db(a) 55/51 61.5/57.5 61.5/57.5 60.5/56.5 Dimensions Lenght mm 860 1.258 1.258 1.448 Width mm 860 860 860 860 Height mm 1.980 1.980 1.980 1.980 MD 102-202 102 132 152 182 202 Total cooling capacity kw 32,3 42,6 48 57,6 64,1 Sensibile cooling capacity kw 29,7 39,5 45 54,5 59,2 Nominal air flow m 3 /s 2,5 3,61 3,89 4,44 4,44 Sound pressure level * (up/down Flow) db(a) 60.5/56.5 64/60 65/61 67/63 67/63 Dimensions Lenght mm 1.448 1.885 2.265 2.265 2.265 Width mm 860 860 860 860 860 Height mm 1.980 1.980 1.980 1.980 1.980 Close control * Sound pressure level measured at 2 m from the machine and at 1 m from the ground in free field conditions.
250 Close Control Remote condenser for Close control CG 010-065 9.4-65 kw 407C Technical features 7 sizes Versions: BLN and LN Air flow: Horizontal and vertical Accessories and options Head pressure control Technical feature CG 010-065 BLN 010 015 020 025 035 045 055 065 Capacity kw 9,4 12,1 18,4 24,4 30,0 41,8 56,2 65,0 Air flow kw 0,9 0,8 1,8 1,7 1,9 4,2 4,0 3,9 Lenght mm 780 780 1.380 1.380 1.105 2.005 2.005 2.005 Width mm 555 555 555 555 828 828 828 828 Height mm 362 362 362 362 428 428 428 428 Weight kg 18,0 19,4 34,0 38,8 46,6 76,0 85,3 93,2 Sound power level db(a) 75 75 78 79 75 78 78 78 Fans Qty 1 1 2 2 1 2 2 2 Diameter mm 400 400 400 400 500 500 500 500 Fans speed rpm 1.430 1.430 1.430 1.430 1.300 1.300 1.300 1.300 Power input W 200 200 400 400 680 1.360 1.360 1.360 CG 010-065 LN 010 015 020 025 035 045 055 065 Capacity kw 7,7 9,7 15,0 18,7 24,2 35,9 43,2 48,7 Air flow kw 0,7 0,6 1,4 1,3 1,3 2,9 2,7 2,6 Lenght mm 780 780 1.380 1.380 1.105 2.005 2.005 2.005 Width mm 555 555 555 555 828 828 828 828 Height mm 362 362 362 362 428 428 428 428 Weight kg 18,0 19,4 34,0 38,8 46,6 76,0 85,3 93,2 Sound power level db(a) 65 65 68 68 67 70 70 70 Fans Qty 1 1 2 2 1 2 2 2 Diameter mm 400 400 400 400 500 500 500 500 Fans speed rpm 940 940 940 940 915 915 915 915 Power input W 160 160 320 320 270 540 540 540 Air temperature= 32 C. Condensing temperature dew= 52 C. S.H.= 25 K. - S.C.= 3 K. * Refer to UNI EN 13487.
Close Control 251 Combination - Close Control remote condenser unit CG BLN Models CG LN Models Size Size Size 031 015 020 041 020 025 CLOSE CONTROL - CD 051 020 025 061 035 035 071 035 045 091 045 045 101 045 055 072 2 x 015 2 x 020 082 2 x 020 2 x 025 102 2 x 020 2 x 025 Size Size Size 061 025 035 071 035 045 091 045 045 101 045 055 CLOSE CONTROL - MD 131 055 065 151 065 085 082 2 x 020 2 x 025 102 2 x 025 2 x 035 132 2 x 035 2 x 035 152 2 x 035 2 x 045 182 2 x 045 2 x 045 202 2 x 045 2 x 055 262 2 x 055 2 x 065 302 2 x 065 2 x 085 Close control
Direct Expansion DK/DN 14.5-83 kw 15.7-83.8 kw 407C XAR + UC 12-55 kw 407C XAO 8-48.7 kw 407C
Direct Expansion 253 Selection guide Direct Expansion Product Range Capacity Flow rate Acoustic Power Size (LxHxP) mm Packaged Air Conditioners Vertical Units Air Cooled Models Packaged Air Conditioners Vertical Units Water Cooled Models Ductable Split- System Air Conditioners X 1200 / UC 34 12 kw 2.000 m 3 /h X 1900 / UC 54 16.2 kw 3.200 m 3 /h X 2450 / UC 74 19.8 kw 4.500 m 3 /h X 3250 / UC 104 29.0 kw 5.800 m 3 /h X 4650 / UC 74 38.9 kw 9.000 m 3 /h X 6450 / UC 104 55 kw 12.000 m 3 /h CX 25 8 kw 1.500 m 3 /h X 1200 AO 15 kw 2.000 m 3 /h X 1900 AO 18.0 kw 3.200 m 3 /h X 2450 AO 23.0 kw 4.500 m 3 /h X 3250 AO 32.4 kw 5.800 m 3 /h X 4650 AO 45.7 kw 9.000 m 3 /h DK / DN 155 14.5 kw 2.850 m 3 /h DK / DN 205 19.1 kw 4.500 m 3 /h DK / DN 255 21 kw 4.680 m 3 /h DK / DN 305 28.5 kw 5.760 m 3 /h DK / DN 405M 36 kw 7.560 m 3 /h DK / DN 405 37.5 kw 7.560 m 3 /h DK / DN 505 44 kw 9.360 m 3 /h DK / DN 605 56 kw 9.720 m 3 /h DK / DN 755 69.1 kw 12.000 m 3 /h DK / DN 905 83 kw 14.300 m 3 /h I.U. 51dB(A) 890 x 1.540 x 430 O.U. 52 db(a) 885 x 840 x 825 I.U. 56 db(a) 1.000 x 1.735 x 500 O.U. 53 db(a) 885 x 840 x 825 I.U. 59 db(a) 1.300 x 1.840 x 600 O.U. 56 db(a) 1.141 x 840 x 885 I.U. 65 db(a) 1.530 x 1.830 x 600 O.U. 56 db(a) 1.546 x 840 x 885 I.U. 61 db(a) 1.715 x 1.970 x 790 O.U. 56 db(a) 1.141 x 840 x 885 I.U. 69 db(a) 1.980 x 1.970 x 790 O.U. 56 db(a) 1.546 x 840 x 885 52 db(a) 800 x 1.280 x 407 52 db(a) 890 x 1.540 x 430 55 db(a) 1.000 x 1.735 x 500 58 db(a) 1.300 x 1.840 x 600 64 db(a) 1.530 x 1.830 x 600 60 db(a) 1.715 x 1.970 x 790 I.U. 72 db(a) 1.410 x 340 x 745 O.U. 82 db(a) 900 x 1.060 x 800 I.U. 84 db(a) 135 x 400 x 1.000 O.U. 78 db(a) 900 x 1.060 x 800 I.U. 84 db(a) 1.692 x 400 x 1.060 O.U. 78 db(a) 900 x 1.060 x 800 I.U. 78 db(a) 1.690 x 676 x 1.005 O.U. 86 db(a) 1.003 x 1.094 x 1.003 I.U. 83 db(a) 1.690 x 676 x 1.005 O.U. 83 db(a) 1.004 x 1.257 x 1.004 I.U. 83 db(a) 1.690 x 676 x 1.005 O.U. 87 db(a) 1.708 x 972 x 1.123 I.U. 84 db(a) 2.100 x 703 x 1.078 O.U. 86 db(a) 1.708 x 1.171 x 1.123 I.U. 85 db(a) 2.100 x 703 x 1.078 O.U. 86 db(a) 1.708 x 1.171 x 1.123 I.U. 87 db(a) 2.270 x 795 x 910 O.U. 87 db(a) 2.213 x 1.303 x 1.345 I.U. 87 db(a) 2.270 x 945 x 910 O.U. 87 db(a) 2.213 x 1.459 x 1.345 Direct Expansion direct expansion
254 Direct Expansion Air-air split system Cooling and heating DK/DN 14.5-83 kw 407C 15.7-83.8 kw Technical features UNDER version air down flow Cooling Capacity from 14,5 to 83 kw Heating Capacity from 15,7 to 83,8 kw Refrigerant: R407C 12 sizes Configurations Packaged Split system Product Advantages Adjustable base frame Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL 7040 Indoor centrifugal fan units for duct netwrok connection High static pressure available Multi-position architecture for horizontal or vertical mounting (acc. to models) Compact, top discharge outdoor fan units Low noise axial fan Scroll compressor with crankcase heater Electrical, refrigeration and thermal protection devices Phase controller External HP and LP pressure taps Frame and air filter supplied Accessories and options Factory-fitted low ambient temperature control to ensure cooling operation down to -10 C outdoor temperature (All-season) Electric heater Programmable controlller RCW2 to control up to 15 units with independent set points and programming Operating limit (for standard unit) (to be confirmed following selection software issue) Cooling mode Minimum indoor air temperature Maximum indoor air temperature Minimum outdoor air temperature/with all-season kit Maximum outdoor air temperature Heating mode Maximum indoor air temperature Minimum outdoor air temperature Maximum outdoor air temperature 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS 27 C BS -10 C 24 C BS/18 C BH
Direct Expansion 255 Technical feature DK-DN DK 155 DK-V 155 DK 205 DK 255 Indoor unit Cool only DN 155 DN 155 DN 205 DN 255 Reversible DN 155RC DN 155RC DN 205RC DN 255RC Capacities Cooling capacity kw 14,5 14,5 19,1 21,0 Cooling Power input kw 5,8 5,8 7,3 8,6 EER 2,5 2,5 2,6 2,4 Heating capacity kw 15,7 15,7 18,3 21 Heating Power input kw 5,8 5,8 6,7 7 COP 2,7 2,8 3 2,9 Indoor unit Available static pressure Pa 130 110 210 210 Fan Nominal Airflow m 3 /h 2.850 2.850 4.500 4.680 Airflow range (min/max) m 3 /h 2.300/3.100 2.300/3.100 3.600/5.000 3.800/5.100 Sound Levels Sound power level db(a) 73 72 84 84 Dimensions LxWxH mm 1.350 x 745 x 340 1.254 x 972 x 350 1.352 x 1.060 x 400 1.692 x 1.060 x 400 Mounting H/V H H/V H H Weight Unit weight kg 65 77 98 100 Outdoor unit Fan Number of fan 1 1 1 1 Nominal Airflow m 3 /h 9.000 9.000 9.000 9.000 Sound Levels Sound power level db(a) 82 82 78 78 Dimensions LxWxH mm 900 x 800 x 1.060 900 x 800 x 1.060 900 x 800 x 1.060 900 x 800 x 1.060 Weight Unit weight kg 150 150 164 164 Power supply Power supply V/P/Hz 400V/3~N/50Hz Power supply side Outdoor Pipe Line Suction pipe diameter < 20m inches 7/8 7/8 1-1/8 1-1/8 Suction pipe diameter > 20m inches 3/4 3/4 1-1/8 1-1/8 Liquid pipe diameter < 20m inches 1/2 1/2 1/2 1/2 Liquid pipe diameter > 20m inches 1/2 1/2 5/8 5/8 Max lenght m 50 50 30 30 Max height m 50 50 15 15 Direct Expansion direct expansion
256 Direct Expansion Technical feature DK-DN DK 305 DK 405 M DK 405 Indoor unit Cool only DN 305 DN 405 M DN 405 Reversible DN 305RC DN 405 mrc DN 405RC Capacities Cooling capacity kw 28,5 36,0 37,5 Cooling Power input kw 11,5 13,9 14,4 EER 2,5 2,6 2,6 Heating capacity kw 27,3 36,0 36,5 Heating Power input kw 9,3 13,3 11,9 COP 2,7 3 2,9 Indoor unit Available static pressure Pa 190 180 180 Fan Nominal Airflow m 3 /h 5.760 7.560 7.560 Airflow range (min/max) m 3 /h 4.600/6.300 6.000/8.200 6.000/8.200 Sound Levels Sound power level db(a) 78 83 83 Dimensions LxWxH mm 1.690 x 1.005 x 676 1.690 x 1.005 x 676 1.690 x 1.078 x 676 Mounting H/V H H H Weight Unit weight kg 150 160 160 Outdoor unit Fan Number of fan 1 1 1 Nominal Airflow m 3 /h 9.000 16.000 2x9.000 Sound Levels Sound power level db(a) 86 83 87 Dimensions LxWxH mm 1.003 x 1.003 x 1.094 1.004 x 1.004 x 1.257 1.708 x 1.123 x 972 Weight Unit weight kg 187 247 317 Power supply Power supply V/N/Hz 400V / 3~N / 50Hz Power supply side Outdoor Pipe line Suction pipe diameter < 20m inches 7/8 1-3/8 7/8 Suction pipe diameter > 20m inches 1-1/8 1-3/8 7/8 Liquid pipe diameter < 20m inches 5/8 5/8 1/2 Liquid pipe diameter > 20m inches 5/8 5/8 5/8 Max lenght m 30 30 30 Max height m 15 10 15
Direct Expansion 257 Technical feature DK-DN DK 505 DK 605 DK 755 DK 905 Indoor unit Capacities Cooling Heating Indoor unit Fan Cool only DN 505 DN 605 DN 755 DN 905 Reversible DN 505RC DN 605RC DN 755RC DN 905RC Cooling capacity kw 44,0 56,0 69,1 83,0 Power input kw 16,7 22,5 26,9 33,0 EER 2,6 2,5 2,6 2,5 Heating capacity kw 42,0 57,5 71,0 83,8 Power input kw 14,4 22,9 26,4 32,4 COP 2,5 2,7 2,6 2,5 Available static pressure Pa 520 320 330 460 Nominal Airflow m 3 /h 9.360 9.720 12.000 14.300 Airflow range (min/max) m 3 /h 7.500/10.300 7.780/11.000 9.600/13.200 11.440/15.730 Sound Levels Sound power level db(a) 84 85 87 87 2.100 x 1.078 x 703 2.100 x 1.078 x 703 2.208 x 949 x 795 2.208 x 949 x 945 Dimensions LxWxH mm Mounting H/V H H H H Weight Unit weight kg 205 209 266 282 Outdoor unit Fan Number of fan 2 2 2 2 Nominal Airflow m 3 /h 2x9.000 2x9.000 2x16.000 2x16.000 Sound Levels Sound power level db(a) 86 86 87 87 Dimensions LxWxH mm 1.708 x 1.123 x 1.171 1.708 x 1.123 x 1.171 2.213 x 1.345 x 1.309 2.213 x 1.345 x 1.459 Weight Unit weight kg 378 405 559 592 Power supply Power supply 400V / 3~N / 50Hz Power supply side Outdoor Pipe line Suction pipe diameter < 20m inches 7/8 1-1/8 1-1/8 1-3/8 Suction pipe diameter > 20m inches 7/8 1-1/8 1-3/8 1-3/8 Liquid pipe diameter < 20m inches 1/2 1/2 5/8 5/8 Liquid pipe diameter > 20m inches 5/8 5/8 5/8 5/8 Max lenght m 30 30 30 30 Max height m 15 15 15 15 Direct Expansion direct expansion
258 Direct Expansion Vertical air cabinet Cooling only XAR+UC 12-55 kw 407C FActory Technical features Cooling Capacity: from 12 to 55 kw Refrigerant: R407C Size: 6 Configurations Split system Product Advantages Adjustable base frame Easy installation and maintenance Split system with outdoor condenser fan unit Treated air distribution to premise by plenum or duct network Adjustable available static pressure Temperature control by thermostat Electrical, refrigeration and thermal protection devices Accessories and options Room thermostat Electric heater Hot water heating coil All season system (Cooling mode operation) down to outdoor temperature of -10 C) Remote fault reporting Plenum Duct flange Valves Pipe link Operating limit (for standard unit) (to be confirmed following selection software issue) Indoor unit Minimum air temperature (room/intake/around unit) Maximum air temperature (room/intake/around unit) Outdoor unit Minimum air temperature/with all-season kit Maximum air temperature 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS
Direct Expansion 259 Technical feature X AR X 1200 AR X 1900 AR X 2450 AR X 3250 AR X 4650 AR X 6450 AR Cooling Cooling capacity kw 12,3 16,2 19,8 29,0 38,9 55,0 Power input kw 4,1 6,8 8,9 12,6 16,9 24,0 EER 3,00 2,38 2,22 2,3 2,3 2,3 Cooling circuit 1 1 1 1 2 2 Fans Available static pressure Pa 200 300 200 200 250 290 Nominal Airflow m³/h 2.000 3.200 4.500 5.800 9.000 12.000 Airflow range (min/max) m³/h 1.500/2.500 2.500/3.800 3.600/5.400 4.600/7.000 7.200/10.800 9.500/14.500 Sound levels Sound power level db(a) 62 68 75 81 77 85 Dimensions LxWxH mm 890 x 430 x 1.540 1.000 x 500 x 1.735 1.300 x 600 x 1.840 1.530 x 600 x 1.840 1.715 x 790 x 1.970 1.980 x 790 x 1.970 Plenum height mm 220 260 350 350 400 400 Weight Unit weight kg 136 182 265 350 525 600 Outdoor Unit UC 34 UC 54 UC 74 UC 104 UC 74 UC104 Condenser unit 1 1 1 1 2 2 Fans Nominal Airflow m 3 /h 260 260 350 350 400 400 Sound levels Sound power level db(a) 53 58 61 73 64 76 Dimensions LxWxH mm 885 x 825 x 831 885 x 825 x 831 1.141 x 885 x 831 1.546 x 885 x 893 1.141 x 885 x 831 1.546 x 885 x 893 Weight Unit weight kg 59 68 93 130 93 130 Power supply Power supply 400V / 3~N / 50Hz Power supply side Inside Pipe line Suction pipe diameter inches 1/2 1/2 5/8 3/4 5/8 3/4 Liquid pipe diameter inches 3/8 3/8 1/2 5/8 1/2 5/8 Max lenght m 45 45 45 45 45 45 Direct Expansion direct expansion
260 Direct Expansion Vertical water cabinet cooling only XAO 8.0-45.7 kw 407C FActory Technical features Cooling Capacity: from 8 to 45,7 kw Refrigerant: R407C Size: 6 Configurations Monobloc system Product Advantages Easy installation and maintenance Monobloc system Public or recycled water operation Treated air distribution to premise by plenum or duct network Adjustable available static pressure Temperature control by thermostat Electrical, refrigeration and thermal protection devices Accessories and options Room thermostat Electric heater Hot water heating coil Remote fault reporting Plenum Duct flange Operating limit (for standard unit) (to be confirmed following selection software issue) Indoor unit Minimum air temperature Maximum air temperature Minimum water temperature Maximum water temperature 21 C BS/15 C BH 32 C BS/23 C BH +10 C +30 C
Direct Expansion 261 Technical feature X AO CX 25 X 1200 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO Cooling Cooling capacity kw 8,0 15,0 18,0 23,0 32,4 45,7 Power input kw 2,6 4,2 5,3 7,1 9,8 13,9 EER 3,14 3,57 3,4 3,24 3,31 3,29 Cooling circuit 1 1 1 1 1 2 Fans Available static pressure Pa 80 200 250 200 250 250 Nominal Airflow m³/h 1.500 2.000 3.200 4.500 5.800 9.000 Airflow range (min/max) m³/h 1.160/ 1.750 1.500/ 2.500 Water Connections Wasted water Water flow m 3 /h 0,34 0,91 0,95 1,45 2 2,8 Pressure drop kpa 20 37 30 42 40 18 Recycled water Water flow m 3 /h 1,17 3,2 3,05 4,3 5,8 8,3 Pressure drop kpa 21 80 65 60 40 56 Sound levels Sound power level db(a) 64 65 67 74 80 76 Power supply Power supply V/N/Hz 230V/1~/50Hz 400V/3~N/50Hz 400V / 3~N / 50Hz Dimensions LxWxH mm 800 x 407 x 1.280 890 x 430 x 1.540 2.500/ 3.800 1.000 x 500 x 1.735 3.600/ 5.400 1.300 x 600 x 1.840 4.600/ 7.000 1.530 x 600 x 1.840 7.200/ 10.800 1.715 x 790 x 1.970 Weight Plenum height mm 300 220 260 350 350 400 Unit weight kg 125 151 199 305 380 565 Direct Expansion direct expansion
262 HPT Hydrokit HPT Hydrokit Technical features 48 sizes Structurally equipped of tank, expansion tank, pump, filter, control valves, electrical box 6 volumes of the storage tank from 300 to 2.500 liters 14 different pumps models Two versions: with one or two water pumps Anti freezer protection 6 8 3 1 1 Tank 2 Circulating pump 11 3 Expansion tank 4 Pressure gauge 5 On/Off valves 6 Safety valve 5 2 7 Automatic air vent valve 8 Air vent valve 9 Make-up valve 10 Automatic make-up unit 11 Electrical board 12 Non-return valve (only on version with 2 pumps) 13 Water storage drain 12 7 10 4 13 9
HPT Hydrokit 263 Technical feature Pump model A В С D E F G H I L M О P Q Tank volume Wsb1 Wsb2 F.L.I. F.L.A. F.L.A. (400/3/50) (230/3/50) Q MIn H Max Q Max H Min Ve lt kg kg kw A A m 3 /h кpа m 3 /h кpа lt 300 186 216 1,1 2,5 4,3 6 188 24 83 25 500 208 238 1,1 2,5 4,3 6 188 24 83 25 300 188 220 1,5 3,2 5,5 6 220 24 122 25 500 210 242 1,5 3,2 5,5 6 220 24 122 25 300 188 220 1,5 3,4 5,9 10 170 45 61 25 500 210 242 1,5 3,4 5,9 10 170 45 61 25 300 191 225 2,2 4,8 8,3 10 230 45 112 25 500 213 247 2,2 4,8 8,3 10 230 45 112 25 300 194 231 3 5,6 9,7 10 230 45 112 25 500 215 253 3 5,6 9,7 10 248 45 137 25 750 341 428 3 6,2 10,8 30 191 72 103 25 1000 364 455 3 6,2 10,8 30 191 72 103 25 1500 513 586 3 6,2 10,8 30 191 72 103 2 x 25 2500 565 638 3 6,2 10,8 30 191 72 103 3 x 25 750 370 485 5,5 11 30 308 84 145 25 1000 392 512 5,5 11 30 308 84 145 25 1500 565 696 5,5 11 30 308 84 145 2 x 25 2500 613 732 5,5 11 30 308 84 145 3 x 25 750 373 493 5,5 11 48 210 108 137 25 1000 396 520 5,5 11 48 210 108 137 25 1500 569 696 5,5 11 48 210 108 137 2 x 25 2500 617 740 5,5 11 48 210 108 137 3 x 25 750 377 501 7,5 14,6 48 260 120 180 25 1000 400 528 7,5 14,6 48 260 120 180 25 1500 569 696 7,5 14,6 48 260 120 180 2 x 25 2500 617 740 7,5 14,6 48 260 120 180 3 x 25 750 377 501 11 21,2 48 342 120 249 25 1000 400 528 11 21,2 48 342 120 249 25 1500 569 696 11 21,2 48 342 120 249 2 x 25 2500 617 740 11 21,2 48 342 120 249 3 x 25 1500 628 814 15 28,6 48 405 138 288 2 x 25 2500 680 866 15 28,6 48 405 138 288 3 x 25 1500 634 826 15 28,6 84 330 180 220 2 x 25 2500 686 878 15 28,6 84 330 180 220 3 x 25 1500 646 850 18,5 34,2 84 385 216 220 2 x 25 2500 698 902 18,5 34,2 84 385 216 220 3 x 25 1500 660 878 22 40,3 84 475 180 325 2 x 25 2500 712 930 22 40,3 84 475 180 325 3 x 25 PVe Ps T Min bar bar C 1,5 3-10 Legend: F.L.I. - Full load power. F.L.A. - Full load current. Q Min - Minimum flow. Q Max - Maximum flow. H Min - Minimum pressure. H Max - Maximum pressure. Wsb1 - Shipping weight with pump. Wsb2 - Shipping weight with two pumps. Ve - Expansion tank capacity. Pve - Tank pressure. Ps - Maximum operating pressure. T Min - Minimum water temperature. HPT Hydrokit
Notes
Notes
Systemair srl Via XXV Aprile, 29 20825 Barlassina (MB) Italy Tel. +39 0362 680 1 Fax +39 0362 680 693 www.systemair.com Systemair AC SAS Route de Verneuil 27570 Tillières-sur-Avre France Tel. +33 02 32 60 61 00 Fax +33 02 32 32 55 13 www.systemair.fr Systemair December 2015 AIR CONDITIONING CATALOGUE GB E34015 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos.