ICON Server box installation manual Rev. 1.1



Similar documents
Product and functional description

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

SURGE PROTECTIVE DEVICES

Notes on Product Changeover

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ACS-30-EU-EMDR-10-MOD

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Product Information. HMC 6 Hybrid Motor Cable

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Remote Monitoring and REC 501 Control Unit Product Guide

HERZ-Thermal Actuators

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Universal control module for motorized devices

=============================== WARNING

KNX Panasonic Air Conditioners

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Introduction. Page 2 / 9

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus TCP master

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

How To Power A Schen

IntesisBox Modbus Server Fidelio IP

User Manual for CH-PFC76810

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

ZC-24DO CANopen I/O Module: 24 Digital Outputs

E-STOP relays, safety gate monitors

Safety Manual BT50(T) Safety relay / Expansion relay

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ASSEMBLED SOCKET-COMBINATIONS

400 Series - Mini USB Buccaneer

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

HARTING Ethernet Cabling 8-poles Overview

HM-W536 Install Guide

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Inductive Proximity Sensors

Electronic Control Devices The European Product Catalogue 2007

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

Power Commander Power Distribution Units from Wiremold/Legrand offer

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

DALI RC BASIC SO. Control unit Operating instructions

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

Application/Connection Examples

I STAR COMPUTER CO., LTD

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

IntesisBox Modbus Server SAMSUNG Air Conditioners

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Three-Phase Electric Power Distribution for Computer Data Centers

IntesisBox KNX - LON

Absolute Rotary Encoder E6CP

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Installation Instructions. ThermoCall TC4. Entry/Advanced

Rack mounted telephone- and leased line modem for industrial applications

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Chemical resistance Accidental

A good connection. International approvals.

Contents. Document information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

POWERBLOCK - POWER AMPLIFIER

TX OPEN RS232/485 module

How to read this guide

Intersection Preassembled 19-inch Rack

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Floodlight Range Installation Guide

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

EGSTON Standard E2xFxWx 12W

User's Guide. True RMS Industrial Multimeter

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

R60 USB to CAN interface Manual (1.5 EN)

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited


Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

LIEBERT VNSA Installation Sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ViZion Installation Guide

Electronic Control Devices The European Product Catalogue 2007

PROXIMITY CARD READERS C-10, C-20, C60, C70

Cross-beam scanning system to detect slim objects. 100 mm in

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

Universal MATE-N-LOK Connector System

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

DCS Input/Output Relay Card Series

Transcription:

ICON Server box installation manual Rev. 1.1

Contents 1.0 About this manual... 3 2.0 Intended use... 3 2.1 European WEEE directive... 3 3.0 Installation and service instructions... 4 Server box overview... 4 Installation of the 24V cables from the playground... 5 Setting the DIP switches:... 8 Installation of 110V/230V power cable... 9 Replacing fuses... 9 Server PCB overview... 10 4.0 Technical specifications... 12 4.1Certifications... 13 4.3 Maintenance instructions... 15 Appendix 1... 16 Assembly of old cable system:... 16 Appendix 2... 17 Replacing old server (rev 1.0) with the new server (rev 1.2)... 17-2 -

1.0 About this manual This manual describes the installation and maintenance of the Server box for ICON playgrounds. It also includes technical specifications and information about certifications. 2.0 Intended use The ICON Server box is a system designed for powering and controlling up to 6 structures on an ICON playground. The build in LINUX server controls the gaming; utilizing 6 CAN bus output ports. The 24V power supply utilizes 6 power outputs each fused by 4A. A build in day/week timer gives the option of powering the playground off at periods. The ICON Server box is specially designed and approved for use with ICON equipment only. Installation instructions described in this manual must be followed. If the installation, use and maintenance of the ICON Server box, described in this manual are violated, the protection provided by the Server box may be impaired! 2.1 European WEEE directive All electronic components of ICON are subject to the European WEEE directive and must at the lifecycle end be recycled according to the directive. The electronic components are marked with WEEE recycle mark. - 3 -

3.0 Installation and service instructions Server box overview Main 110/230V circuit breaker 16A Resettable Fuses Installation manual 24V power supply and LINUX server! Electrical specifications Test button / indicator lamp - 4 -

OBS! BEFORE ANY WORK WITHIN THE SERVER BOX IS DONE THE MAIN CIRCUITBREAKER MUST BE SWITCHED OFF!!! 16A resettable fuse Switch to the off position! Installation of the 24V cables from the playground Preparing the cables: 1) Dismantle the cable by app. 70mm 2) Cut off the filler cords 3) Cut off the white and yellow wires 4) Dismantle the inner cords by 5mm - 5 -

5) Mount the wire ferrules using a special plier 6) Final result See specification below! Wire Ferrules for CAN bus (blue & green wire): Kompan order no: A900648-99 Wire Ferrules for 24V (Orange & Black wire): Kompan order no: A900648-99 Crimping Pliers for End Sleeves (ferrules) Knipex: Kompan order no: A900638-99 Connecting the cables: 1) Put on the screw cap 2)Put cable through the fastener and fasten properly 3) Unscrew the cable fitting 4) Twist the shield cords around the cable jacket - 6 -

5) Put on the cable fitting 6) Fasten the cable to the copper rail 6) Mount the wires according to the colors in the 7) Cable mounted, mount the remaining cables in PCB-terminals, starting with orange at the left. The same way OBS! The special terminal opener tool from Wago MUST be used for mounting the wires! Wago order no:236-332 - 7 -

Setting the DIP switches: The tree DIP switches S4, S3, S2 must be set to either the ON or OFF position depending on how the cables are mounted in the cable connectors (see table below). The ON position is printed on the top of the switches. The OFF position is the opposite position. Note that there are two separate actuators on each switch. They must both be set to the same position. S4 S3 S2 0A 0B 1A 1B 2A 2B NO Cable S4= ON S3= ON S2= ON One Cable S4= ON S3= ON S2= ON Two Cables S4= OFF S3= OFF S2= OFF - 8 -

Installation of 110V/230V power cable Installation of the 110/230V power cable must be done in compliance to local rules and regulations for fixed installations. The installation must be done by an authorised electrician or an equal qualified person. Connect the power cable to the following terminals: Gray = Phase, Blue = Neutral Yellow/Green = Protective ground Power cable Replacing fuses 1) Remove and replace the 4A fuse by hand. OBS! Fuses must only be replaced by fuses of same types and ratings. Type : Little fuse, MINI Blade Fuse Rated 32V, no: 0297004_ 4 A 121 mv 23.48 mω 17 A²s - 9 -

Server PCB overview P1 24V Input from transformer P1.1= 0V P1.2= +24V P2 Test lamp / pushbutton connection P2.1= +24V P2.5= button input P2.6= lamp output P2.2-P2.4= lamp output CAN 0-2 Connectors for playground cables Orange= +24V Black= 0V Green= Blue= CAN-H CAN-L - 10 -

Details of the CAN connectors The following connectors J9-J19 is for debug or production use only. They are not in use after installation of a playground! J9 J12 J13 J14 J15 J16 J19 Fuses 1a-6a Modem debug interface Serial debug port FPGA debug port Aux 5V COM port, not used Aux COM, not used Aux USB, used Ethernet/USB connector for debugging Type: Little Fuse MINI Blade Fuse Rated 32V, no: 0297004_ 4 A 121 mv 23.48 mω 17 A²s - 11 -

4.0 Technical specifications Technical specification: Panel dimensions HxWxD : 865 x 611 x 336mm Manufacturer : Pro-Automatic A/S, Sønderrmarken 16, DK-6670 Holsted Pro no. : YYYWWNNN Standard : EN60439-1/-3 Type current and frequency: AC 50-60Hz Rate operations voltage : 100 240VAC Max short circuit current : 6kA Max fuse / I peak : 16A type gl Degree of protection : IP44 Current : 16A Internal separation : Form 1 Color : Grey Supply cable : 3x2,5mm² CU / 3xAWG10, type according to local System earthing : TT / TN-S Temperature range : -35...40 C Contact information to manufacturer of Server box: Electrical panel. : Pro- Automatic A/S Sønderrmarken 16 DK-6670 Holsted Tlf. +45 7539 1100 Web: www.pro-automatic.dk E-mail: pro@pro-automatic.dk Kompan contact : Korsvangen 11 DK-5750 Tlf. +45 6362 1250 Web: www.kompan.com E-mail: Equipment ratings: See electrical diagrams. - 12 -

4.1Certifications 3183264 Conforms to UL std. 61010-1 second edition Certified to CAN/CSA std. C22.2 No. 61010 second edition - 13 -

- 14 -

4.3 Maintenance instructions 0.0 Basic principles: 0.1 The purpose of the maintenance is to point out that the panel is in accordance with the regulations valid at the time of production or re-construction. 0.2 Special attention has to be paid to the examination and control of conditions and material regarding the safety of persons, domestic animals and property. 0.3 As the craftsmanship concerns the maintenance has to be done properly and well by qualified persons and by using suitable material and tools. 1.0 Periodic maintenance At least once a year a visual control of the outer capsulations of the panel has to be made to ensure that enclosure is intact. Open the door of the server box and check for damages inside the box. - 15 -

Appendix 1 Assembly of old cable system: Follow the instructions in section Preparing the Cables in this document and mount the cable as shown in the following picture: 1.5 sqr. Brown to the Orange connector 1.5 sqr. Blue to the Black connector Brown CAN wire to the Green connector Blue CAN connector to the Blue connector - 16 -

Appendix 2 Replacing old server (rev 1.0) with the new server (rev 1.2) 1. Mark carefully the wires on J1 and J17 according to the terminal numbers on the schematic below: Old Server - 17 -

2. Transfer the wires to the new server according to the table and the schematic of the new server below: Old server New server J1.1 P1.2 +24V in J1.2 P1.1 0V in J1.3 Remove this wire J1.5 P2.1 J1.6 Remove this wire J17.5 P2.5 J17.6 P2.6 J6.1,2,3,4,5,7,8 Remove all wires New server - 18 -

- 19 -