Data Centre & Enterprise Solutions. RapidNet

Similar documents
Data Center Solutions

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center Solutions. Network Cabling Products

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

IT Cabling Solutions

Copper Pre-terminated Assemblies

AMP NETCONNECT Data Center Cabling Solutions

InstaPATCH ZERO Solution Guide

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

InstaPATCH Cu Cabling Solutions for Data Centers

Excel Pre-terminated Copper and Fibre Optic Systems

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Innovative Connectivity Solution for Maximum Performance and Security

Zone Distribution in the Data Center

Category 6 UTP - Cabling System

MPO. Fast Fibre Solution for Data Centres

Cable Assembly Solutions at the Speed of Light

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Network Design. Yiannos Mylonas

Accelerating Light. Copper Cabling Solutions. Category 6A

Reliable, Consistent, Quality

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Arista and Leviton Technology in the Data Center

Arista 40G Cabling and Transceivers: Q&A

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

How To Make A Data Center More Efficient

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

FriendlyNET FX Slot Modular Switch. User s Manual

Patch Cords for Data Center Applications

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

The High Cost of a Low-Cost Cable Certification Tester

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Data Center Architecture with Panduit, Intel, and Cisco

AMP NETCONNECT. EMEA Product Catalog

Structured and Point to Point Network Cabling for Industrial Automation

Corning Cable Systems Optical Cabling Solutions for Brocade

Pretium EDGE HD Solutions

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Overcoming OM3 Performance Challenges

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Data Center Network Infrastructure The Smart Choice For Your Data Center

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

hot products guide people. passion. expertise. gocsc.com

16-Port and 24-Port 10/100 Switches

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Panduit 28 AWG Patch Cords Installation Guideline

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Keyed LC Connector Solution

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

ADC-APC Integrated Cisco Data Center Solutions

DATA CENTRES POWERED BY EXCEL

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

Data Center Cabling Design Trends

SIEMON Data Center Solutions.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Fiber in the Data Center

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

SYSTIMAX Solutions. Intelligent Infrastructure (ipatch) Solutions Guide

MapIT G2 Infrastructure Management

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

INTELLIGENT INFRASTRUCTURE MANAGEMENT

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

Gigabit Switching Ethernet Media Converters - Product User Guide

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Connector and Cable Specifications

Copper Closet. Copper Closet

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Uniprise Solutions. Information Security Network Solutions

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Copper Cabling Infrastructure Offering

Pretium Connector Housings

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

How To Plan A Data Center Network

MTP Optical Fibre Configurations

ADC Structured Cabling Solutions

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Obsolete Fiber Technology? Not in my Data Center!

MapIT. G2 Infrastructure Management. Section Contents. MapIT G2 INFRASTRUCTURE MANAGEMENT 8.0

The Need for Low-Loss Multifiber Connectivity

Data Communications Competence Center

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Transcription:

H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet

data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect, manage and identify cable and components. Located in over 30 countries, HellermannTyton utilizes global resources channeled to local implementations to offer its customers an integrated approach to design, operation and delivery. Flexibility, agility and the ability to create value-added, marketdriven results are the hallmarks of every HellermannTyton company across the world. 2

H E L L E R M A N N T Y T O N Applications - Mission Critical Data Centres - Enterprise Data Centres - Disaster Recovery - Storage Area Networks - Redundancy Planning - Central Office and Workspace - Temporary Networks - Server Farms - Cloud Computing - Colocation Facilities - Call Centres - Modular Work Environments - Green Building Solutions RapidNet Network Cabling System RapidNet is HellermannTyton s patented pre-terminated connect and go system which offers high performance in copper and Fibre solutions within the same footprint. Our pre-terminated solutions do not require on-site termination or certification testing so installations are completed in record time while quality and performance are never compromised. Our RapidNet solutions address the critical issues for cabling installations such as minimizing network downtime and disruption to business, increased quality control, consistent repeatable terminations, enhanced security, dramatically reduced installation time and the human resource required on site to complete a successful project on time and within budget. Cut to customer specified lengths, each individual link is terminated, tested and labeled by HellermannTyton before being delivered to the site. Copper Cabling Solutions: CAT 6 UTP, CAT 6 ScTP, CAT 6A F/UTP Material Packaging Options Fibre Cabling Solutions: 62.5/125µm (OM1),50/125µm (OM2), 50/125µm (OM3), 50/125µm (OM4) and Single Mode Copper Fibre Box up to 75 ft* / Reel from 76-295 ft Box up to 200 ft* / Reel 201+ ft *Duplicate, shorter lengths packaged in multiples to condense materials on jobsite. Whether your copper or Fibre solution arrives on site in a box or on a reel, the integrity of the product is never compromised. For product information visit www.hellermann.tyton.com or call 800.661.2461 3

data centre & Enterprise solutions Product Features RNG Series RapidNet Cassette The cassette is the heart of the RapidNet system, allowing for fast installations and full protection of the terminations. Our new RNG Series RapidNet cassette provides the same protection as the classic style cassette but with product enhancements that include twice the density. - Updated Release Mechanism: a quick-release lever that makes the insertion and release of the cassette easier - Alignment Guides - ensure the cassette is properly inserted into the panel - Larger Cassette - allows the higher density options for Fibre in a 1U footprint; up to 96 Fibres/48 ports in 1U - Modular Panel - provides copper and Fibre solutions in the same footprint Copper Cassette Quick-Release Mechanism Integral earthing system in the cassette that connects to springs in the panel, applies to CAT 6A F/UTP solution only Alignment Guides Fibre Cassette Grommet provides additional strainrelief for direct connect solutions Up to 24 Fibres / 12 duplex ports MTP (12 Fibre connector) options Single-Release Lever 4

H E L L E R M A N N T Y T O N Product Features - New cassette design features single-release lever - Cassettes are manufactured from high-strength, light-weight thermoplastic material - Integral grounding system in the cassette connects to springs in the panel to ensure effective grounding of system - Exceeds ANSI/TIA-568-C Category 6A and ISO/IEC 11801:2002 / Amd 2, Class E A - Category 6A cassette loaded with HellermannTyton Category 6A modular jacks - Alignment guides located on the top of the cassette to ensure the correct orientation in the modular panel (RNGSPP1U) - Available in lengths from 10 ft - 295 ft - Permanent Link test results included with all looms/orders - Made in the USA RNG Series RapidNet Category 6A Copper F/UTP Solutions HellermannTyton s Deca 10 Series RapidNet is a Category 6A solution that offers uncompromised support for 10 Gigabit Ethernet. The shielded construction aids higher performance by eliminating the effect of alien crosstalk and external interference, making this an ideal solution for 10 Gigabit Ethernet applications. RapidNet utilizes a bundled cable with six high-performance Category 6A F/UTP cables bound together with a Kevlar binder. The Category 6A cassette is populated with six HellermannTyton Category 6A shielded modular jacks whose die-cast body fully encloses the PCB and cable terminations. The new cassette design offers an integral grounding system in the cassette that connects to springs in the modular panel. The cassette is equipped with a new single-lever release mechanism that makes the insertion and release of the cassette easier to use. FIXED VARIABLE Select the following Prefix Bundle Type Flame Rating Color Termination End 1 Termination End 2 Length RNGC 6 C CAT 6A F/UTP P R * B W * C Cassette C Cassette J Jack-Pair Stagger Right K Jack-Pair Stagger Left L Jack-Stagger Right M Jack-Stagger Left N Jack-Inline 10-295 Pair Stagger Right = 1/2 longest, 3/4 next, 5/6 last and shortest pair. *Options are available with longer lead times and minimum order requirements. Example Model Number: RNGF 6 C R W C C 65 Prefix Term. Term. Length Bundle Type Flame Color End 1 End 2 Rating For product information visit www.hellermann.tyton.com or call 800.661.2461 5

data centre & Enterprise solutions Product Features RNG Series RapidNet Category 6 Copper UTP Solutions RNG Series RapidNet Category 6 is an ideal solution for highperformance cabling requirements, such as Gigabit Ethernet. RapidNet utilizes a six bundled cable that has been specially designed to eliminate potential alien crosstalk issues and is bound together with a Kevlar binder, ensuring a high-quality, well managed installation. Cut to the customer-specified length at HellermannTyton, each 6 port loom is supplied terminated at both ends to at least one of the patented RapidNet cassettes. Lengths up to 75 feet are supplied in the RapidNet box; lengths from 76-295 feet are supplied on the RapidNet reel. - Positive PSCAR over 350 MHz and a typical worst-case margin or 15 db at 250 MHz - Exceeds ANSI/TIA-568-C specifications - Permanent Link test results included with all looms/orders - Cassettes are manufactured from highstrength, light-weight thermoplastic material - New cassette design features singlerelease mechanism - Alignment guides are located on the top of the cassette to ensure the correct orientation in the modular panel (RNGPP1U) - Available in lengths from 10 ft - 295 ft - Made in the USA FIXED VARIABLE Select the following Prefix Bundle Type Flame Rating Color Termination End 1 Termination End 2 Length RNGC 6 A CAT 6 UTP P R B W C Cassette C J K L M N P Q R S T D O Cassette Jack-Pair Stagger Right Jack-Pair Stagger Left Jack-Stagger Right Jack-Stagger Left Jack-Inline Plug-Pair Stagger Right Plug-Pair Stagger Left Plug-Stagger Right Plug-Stagger Left Plug-Inline Pod Open 10-295 Example Model Number: RNGC 6 A R W C C 65 Prefix Term. Term. Length Bundle Type Flame Color End 1 End 2 Rating 6

H E L L E R M A N N T Y T O N Consolidation Point Cabling Topology Consolidation point (CP) Ceiling Void Conduit or free air Fed through drywall, service pole or modular wall system Work stations or office space TR distribution patch panels J K L M N P Q R S T D For product information visit www.hellermann.tyton.com or call 800.661.2461 7

data centre & Enterprise solutions RNG Series RapidNet Fibre Solutions RNG Series RapidNet Fibre is an excellent solution for high bandwidth needs or extended distances. The new RNG Series cassette offers double the density of our classic version, up to 24 Fibre or 12 duplex ports. RapidNet Fibre utilizes a 12 Fibre (6 port), single unit plenum (OFNP) distribution cable for LC and SC connections or a 24 Fibre (12 port) zip cord loose tube plenum (OFNP) cable for LC connections. Cut to customer specified length at HellermannTyton, each 12 or 6 port loom is supplied terminated at both ends to at least one of the patented RapidNet cassettes. Lengths up to 200 feet are supplied in the RapidNet box; lengths of 201 feet or more are supplied on the RapidNet reel. Each pre-labeled 12 or 6 port Fibre cassette snaps easily into the modular panel. Product Features - Exceeds ANSI/TIA-568-C.2 and IEEE 802.3ae 10GbE standards - Certification test reports included with all Fibre looms/orders - Cassettes are manufactured from high-strength, light-weight thermoplastic material - New cassette design features single-release mechanism - Alignment guides located on the top of the cassette to ensure the correct orientation in the modular panel (RNGPP1U) - Modular panel accepts 4 RapidNet cassettes, allowing up to 96 Fibres / 48 ports in 1U FIXED VARIABLE Select the following Prefix Type Flame Rating Termination End 1 Termination End 2 Count No. of Pull Kits Length RNGF A B C H D = 50/125μm (OM3) Multimode = 50/125μm (OM2) Multimode = 62.5/125μm (OM1) Multimode = 50/125μm (OM4) Multimode = Single Mode P = L C S D = LC Cassette = LC APC Cassette = SC Cassette = SC APC Cassette L J K H C S T R Q D = LC Cassette (straight thru) = LC Cassette (REV) = LC 900μm fanout = LC 2.0mm fanout = LC APC Cassette = SC* Cassette (straight thru) = SC* Cassette (REV) = SC* 900μm fanout = SC* 2.0mm fanout = SC APC Cassette A = 12 B = 24 0 1 10-500 * SC versions only available in 12 Fibre cable count. Options are available with longer lead times and minimum order requirements. BIF options are available. Example Model Number: RNGF A P L C A 1 65 Prefix Term. Term. No. of Length Type Flame End. 1 End 2 Count Pull Kits Rating 8

H E L L E R M A N N T Y T O N LC Cassette L - J K H SC Cassette S - T Fibre Options - 62.5/125μm (OM1) Multimode Fibre - 50/125μm (OM2) Multimode Fibre - 50/125μm (OM3) Multimode Fibre - 50/125μm (OM4) Multimode Fibre - 8.3/125μm Single Mode Fibre R Q For product information visit www.hellermann.tyton.com or call 800.661.2461 9

data centre & Enterprise solutions Benefits of the RapidNet RapidNet 12 Port Copper Cassette 12 Port Copper Cassette: Factory termination and testing provides assurance of performance on site, ensures rapid installation, minimizes network Alignment guides The label sits between the two rows of the RJ45 connectors, so one label identifies two ports. To aid identification, the ID window has a built-in magnification lens. downtimes and business disruptions, and allows for retained control. The high-density solution that offers better cabling efficiencies and reduces installation time up to 85%. The pre-terminated solution that reduces personnel access thus minimizing security risks and the waste generated from field Quick-Release Mechanism terminations. RNGPP1UHD The front presentation is two rows of 6 RJ45 connectors mirroring each other. FIXED VARIABLE Select the following Prefix Bundle Type Flame Rating Color Termination End 1 Termination End 2 Length RNGC 12 A CAT 6 UTP P CMP R CMR Example Model Number: RNGC 12 A R W H H 20 Prefix Bundle Type Flame Rating Color Term. End 1 Term. End 2 Length B W H High-Density Cassette H Z J K L M N P Q R S T D High-Density Cassette Split Cassette Jack - Pair Stagger Right Jack - Pair Stagger Left Jack - Stagger Right Jack - Stagger Left Jack - Inline (no stagger) Plug - Pair Stagger Right Plug - Pair Stagger Left Plug - Stagger Right Plug - Stagger Left Plug - Inline (no stagger) Pod 20-140 Part No Description Accessory Pair Stagger Rgt = 1/2 longest, 3/4 next, 5/6 last and shortest pair RNGPP1UHD Modular Patch Panel, RNG Series HD Cassette only, 1U, Black 10

H E L L E R M A N N T Y T O N Product Features - Exceeds ANSI/TIA-568-C and IEEE 802.3ae 10GbE standards - Modular panel accepts 4 RapidNet cassettes, allowing up to 48 Fibres in 1U - Certification test reports included with all Fibre looms/orders Fibre Options - 62.5/125µm (OM1 Fibre) - 50/125µm (OM2 Fibre) - 50/125µm laser optimized 10G (OM3 Fibre) - Single Mode RapidNet Classic Fibre Solutions RapidNet Classic Solutions offer the same performance as the RNG Series, but utilize the first release of the cassette. The Classic cassette and system is for use in existing applications to achieve a consistent appearance. RapidNet Fibre utilizes the LC connector with a 12 Fibre single unit plenum (OFNP) cable. Cut to the customer specified length at HellermannTyton, each 12 Fibre (6 port) loom is supplied terminated at both ends to RapidNet cassettes. Each cassette snaps easily into the modular panel. Removal is just as easy - simply slide the latch forward and the cassette slides out of the rear of the panel. Part No. Description Type Color RNF62PXXX* RapidNet 62.5/125µm (OM1) MM LC assembly, 12 Fibre (6 port) Orange RNF50PXXX* RapidNet 50/125µm (OM2) MM LC assembly, 12 Fibre (6 port) Orange LC Connector Cassette to Cassette (panel to panel) RNF50P10GXXX* RNFSMPXXX* RapidNet 50/125µm (OM3) MM 10 Gig LC assembly, 12 Fibre (6 port) RapidNet 8.3/125µm SM LC assembly, 12 Fibre (6 port) Aqua Yellow * Note: To complete Part No., replace the X s with the length required in feet Additional Information: Standard part number is wired straight through (A-A). To order crossover (A-B), add REV to end of part number. RNFAAAXXXLC* RapidNet LC cassette to 12 LC connectors * Note: To complete Part No., replace the A s with the appropriate Fibre type: 62P, 50P, 50P10G, or SMP. Replace the X s with the length required in feet. Cassette to Connector (panel to enclosure) Example Model Number: RNF 62P 100 Part No. Fibre Type Length For product information visit www.hellermann.tyton.com or call 800.661.2461 11

data centre & Enterprise solutions Product Features RapidNet Classic Category 6 Copper UTP Solutions RapidNet Classic Solutions offer the same performance as the RNG Series, but utilize the first release of the cassette. The Classic cassette and system is for use in existing applications to achieve a consistent appearance. RapidNet utilizes a bundled cable with six high performance Category 6 UTP cables bound together with a Kevlar binder. Cut to the customer specified length at HellermannTyton, each 6 port loom is supplied terminated at both ends to RapidNet cassettes. Each cassette snaps easily into the modular panel. Removal is just as easy simply slide the latch forward and the cassette slides out of the rear of the panel. - Positive PSACR over 350 MHz and a typical worst-case margin of 15 db at 250 MHz - Bundled cable is UL Verified to Category 6, ANSI/TIA-568-C specifications - Permanent Link test reports included with all links - 1U modular panel accepts 4 RapidNet cassettes for 24 ports - 2U modular panel accepts 8 RapidNet cassettes for 48 ports - Available in lengths from 10 ft - 295 ft - Made in the USA Part No. Description Type Color Cassette to Cassette (Panel to Panel) RNC6CMPXXX* RapidNet CAT6 CMP cassette to cassette 6 port loom RNC6CMPWHTXXX* RapidNet CAT6 CMP cassette to cassette 6 port loom RNC6CMRXXX* RapidNet CAT6 CMR cassette to cassette 6 port loom Cassette to Cassette (panel to panel) RNC6CMRBLUXXX* RapidNet CAT6 CMR cassette to cassette 6 port loom Cassette to Jack (Panel to Modular Panel or Faceplate) RNC6JCMPXXX* RapidNet CAT6 CMP cassette to jack 6 port loom RNC6JCMPWHTXXX* RapidNet CAT6 CMP cassette to jack 6 port loom RNC6JCMRXXX* RapidNet CAT6 CMR cassette to jack 6 port loom RNC6JCMRBLUXXX* RapidNet CAT6 CMR cassette to jack 6 port loom * Note: To complete Part No., replace the X s with the length required in feet, 10 to 295 feet. Cassette to Jack (panel to modular panel or faceplate) 12

H E L L E R M A N N T Y T O N Part No. Description Type Color Cassette to Plug (Panel to Plug) RNC6PCMPXXX* to plug 6 port loom RNC6PCMPWHTXXX* to plug 6 port loom Cassette to Plug (panel to plug) RNC6PCMRXXX* to plug 6 port loom RNC6PCMRBLUXXX* to plug 6 port loom Cassette to Open End (Panel to Open End) RNC6OCMPXXX* to open end 6 port loom RNC6OCMPWHTXXX* to open end 6 port loom RNC6OCMRXXX* to open end 6 port loom RNC6OCMRBLUXXX* to open end 6 port loom Cassette to Open End (panel to open end) Cassette to Pod (Panel to Consolidation Point) RNC6PDCMPXXX* to pod 6 port loom RNC6PDCMPWHTXXX* to pod 6 port loom RNC6PDCMRXXX* to pod 6 port loom RNC6PDCMRBLUXXX* to pod 6 port loom * Note: To complete Part No., replace the X s with the length required in feet, 10 to 295 feet. Cassette to Pod (panel to consolidation point) Example Model Number: RNC6PDCMP 165 Part No. Length For product information visit www.hellermann.tyton.com or call 800.661.2461 13

data centre & Enterprise solutions RapidNet Classic Modular Panels and Accessories All RapidNet cassettes utilize our latch design to allow quick and easy installation into modular patch panels. The 1U RapidNet modular patch panel accepts four cassettes, and the 2U modular patch panel accepts eight cassettes. Panels fit standard 19 racks. Part No. Description Port Count RapidNet Modular Panel RNPP2U RNPP1U RapidNet Modular Panel - 1U 24 UTP copper ports 48 LC Fibres / 24 ports 24 SC Fibres / 12 ports RNPP1URS RapidNet Modular Panel - 1U* 24 UTP copper ports 48 LC Fibres / 24 ports 24 SC Fibres / 12 ports RNPP2U RapidNet Modular Panel - 2U 48 UTP copper ports 96 LC Fibres / 48 ports 48 SC Fibres / 24 ports RNPP2URS RapidNet Modular Panel - 2U* 48 UTP copper ports 96 LC Fibres / 48 ports 48 SC Fibres / 24 ports RNBLANK RapidNet Modular Panel Blank Insert N/A RapidNet Modular Panel RNPP1U * With Rack-Snap inserts pre-installed. Rack-Snap - snaps into standard square holes in most cabinets. Complete your installation with our copper and Fibre patch cords, identification solutions and wire management products. RNG Series Blank Insert RNGBLANK 14

H E L L E R M A N N T Y T O N SYSTEM WARRANTY HellermannTyton assures installation dependability and maximum performance with its 25 Year Network Sciences Warranty program. The Network Sciences Warranty guarantees the consistent quality and performance of HellermannTyton s structured cabling products and installed systems for 25 years. The 25 year warranty covers the copper and Fibre connectivity products and cable, ensuring system performance in accordance with the current TIA standards. The 25 Year Network Sciences Warranty is only offered through HellermannTyton Certified Installers. These Certified Installers have been trained and successfully passed the required exams to install a Network Sciences warranted system. HellermannTyton Certified Installers are the essential connection between HellermannTyton connectivity products and the design, installation, testing, and maintenance of a structured cabling system. CHANNEL WARRANTY* Use HellermannTyton connectivity products Use approved horizontal cable Permanent Link test required with approved tester Use only HellermannTyton CAT 5e/CAT 6A patch cords *The Channel is defined as all the horizontal cabling between the Telecommunications Room (TR) and Work Area with the addition of patch cords at each location. The maximum length of the equipment cord, patch cord, and work area cord shall not exceed 10 meters (33 ft.) PRODUCT WARRANTY In addition to a performance warranty, HellermannTyton also offers a lifetime warranty on its connectivity products. This guarantees that products are free of factory defects in material and workmanship. CORPORATE WARRANTY POLICY PROJECT CERTIFICATIONS LINK WARRANTY* Use HellermannTyton connectivity products Use approved horizontal cable Permanent Link test required with approved tester RAPIDNET LINK WARRANTY* Use HellermannTyton copper and/or Fibre RapidNet products Permanent Link test required with approved tester For project certification, one port per cassette must be tested to TIA-568B standards with an approved tester * The Permanent Link is defined as all the horizontal cabling between the Telecommunications Room (TR) and Work Area. This includes cable, modular jacks, patch panels, and an optional consolidation point. The maximum length that the horizontal cabling can be as defined in TIA/EIA-568-B.1 is 90 meters (295 ft.). HellermanTyton Products are warranted to be free from defects in material and workmanship at the time sold by us; but our obligation under this warranty and that of the seller is limited to the replacement of the product, and neither we nor the seller are bound by any other warranty, expressed, implied or statutory. Under no circumstances are we or the seller liable for any loss, damage, expenses or consequential damages of any kind arising out of the use or inability to use these products. All are sold with the understanding that the user will test them in actual use and determine their adaptability for the intended uses. The above warranties and remedies are exclusive and in lieu of all other warranties and remedies whatsoever, expressed or implied, including but not limited to, any implied warranties of merchantability or fitness for a particular purpose which HellermannTyton expressly disclaims. For more warranty information, go to: www.hellermann.tyton.com For product information visit www.hellermann.tyton.com or call 800.661.2461 15

HellermannTyton Canada 205 Industrial Parkway North, Unit #4 Aurora, Ontario L4G 4C4 Canada Phone: 1.800.661.2461 Fax: 1.800.390.3904 Email: sales@hellermanntyton.ca HellermannTyton North American Corporate Headquarters 7930 N Faulkner Rd. P.O. Box 245017 Milwaukee, WI 53224-9517 Phone: 414.355.1130, 1.800.537.1512 Fax: 414.355.7341, 1.800.848.9866 Email: corp@htamericas.com TS16949:2002, ISO 9001:2000 and ISO 14001 certified Network Sciences Partner - Western Canada Region pcc Group Limited Web: www.pccgroup.ca phone: 403-455-2050 LITPD247 HellermannTyton December 2011 Printed In USA www.hellermann.tyton.com I 800.661.2461