DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver



Similar documents
155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

155Mbps DFB SFP Optical Transceiver, 120km Reach

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

4.25Gbps SFP Optical Transceiver, 30km Reach

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

1.25Gbps GBIC Optical Transceiver, 20km Reach

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

Product Specification 10Gb/s BIDI SFP+ Transceiver

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

LONGLINE 2km XFP Optical Transceiver

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

10/100/1000BASE-T SFP Transceiver

DWDM SFP Series. Power budget* (note2) Laser

XFP Optical Receiver, 80km Reach

DWDM SFP Series. Power budget* (note2) Laser

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Dual Fiber SFP Series

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

LONGLINE 40km XFP Optical Transceiver

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

GPON OLT Optical Transceiver SFP Module RTXM Features

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

X2 LR Optical Transponder, 10Km Reach

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

10GBASE -LRM, 220m Reach GX LRMC

EPON ONU Optical Transceiver SFF Module

10GBASE-SR XFP Optical Transceiver AXM751

10GBASE-LR XFP Optical Transceiver AXM752

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

Part No. Data Rate Wavelength Interface Temp. DDMI

Intel Ethernet SFP+ Optics

1000BASE-BX-OLT Transceiver

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel AGM731F

GBIC CWDM 40km Part no:

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

SFP Copper Transceiver 10/100/1000Base-T

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

155Mbps ATM-Single Mode Transceiver

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

Cisco SFP Optics for Gigabit Ethernet Applications

Enabling the Business Continuity & Change the way business communicates

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat

Dispersion penalty test 1550 Serial

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Un-cooled Multimode Pump Laser Module for Telecom Applications

Wideband Driver Amplifiers

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter

Specification. For. LCD Module CCM1620CSL

Photolink- Fiber Optic Receiver PLR135/T1

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

DS1307ZN. 64 x 8 Serial Real-Time Clock

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

User manual Rev. 1.2 (17/04/2015)

Golden test for dispersion penalty 1550 Serial

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

VS-500 Voltage Controlled SAW Oscillator

LOW POWER SPREAD SPECTRUM OSCILLATOR

DS Wire Digital Thermometer and Thermostat

Features. Dimensions

HARTING mcon 1000 Introduction and features

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

RLG842WVGPON ONU SPEC. RLG842WV GPON ONU Specifications

HARTING econ 3000 Introduction and features

Features. Dimensions

Signal Types and Terminations

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

Features. Dimensions

Application Note 5016

Y.LIN ELECTRONICS CO.,LTD.

RTS5401. USB 3.0 Super-Speed HUB Controller DATASHEET. Doc Rev th Apr i Rev 0.90

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

SP490/491 Full Duplex RS-485 Transceivers

+5 V Powered RS-232/RS-422 Transceiver AD7306

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

IPS511/IPS511S FULLY PROTECTED HIGH SIDE POWER MOSFET SWITCH. Load

Fiber Optics and Liquid Level Sensors Line Guide

4N25 Phototransistor Optocoupler General Purpose Type

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

Transcription:

产 品 规 格 书 Product Specification Sheet DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

PRODUCT FEATURES Up to 1.25Gb/s data links FP laser transmitter for DTSB35(53)12L-CD20 DFB laser transmitter for DTSB53(35)12L-CD20 PIN photo-detector Up to 20km on 9/125μm SMF Hot-pluggable SFP footprint BIDI LC/UPC type pluggable optical interface Low power dissipation Metal enclosure, for lower EMI RoHS compliant and lead-free Single +3.3V power supply Support Digital Diagnostic Monitoring interface Compliant with SFF-8472 Case operating temperature Commercial: 0 C to +70 C Extended: -10 C to +80 C Industrial: -40 C to +85 C APPLICATIONS Switch to Switch Interface Fast Ethernet Switched Backplane Applications Router/Server Interface Other Optical Links STANDARD SFP+ MSA Compliant SFF-8472 reversion 9.5 compliant IEEE802.3-2005 compliant Telcordia GR-468-CORE compliant FCC 47 CFR Part 15,Class B compliant FDA 21 CFR 1040.10 and 1040.11,class1 compliant RoHS compliant

PRODUCT DESCRIPTIONS Datocom DTSB35(53)12L-CD20 optical transceivers are designed optical interfaces for data communications with single mode fiber (SMF). The transceiver designs are optimized for high performance and cost effective to supply customers the best solutions for telecom applications. for FUNCTIONAL DIAGRAM Ordering information Product part Number Data Rate (Gbps) Media Wavelength (nm) Transmission Distance(km) Temperature Range (Tcase)( ) DTSB35(53)12L-CD20 1.25 DTSB35(53)12L-ED20 1.25 DTSB35(53)12L-ID20 1.25 Single mode fiber 1310/1550(1550/1310) 20 0~70 commercial Single mode fiber 1310/1550(1550/1310) 20-10~80 extended Single mode fiber 1310/1550(1550/1310) 20-45~85 industrial

ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min. Max. Unit Note Supply Voltage Vcc -0.5 4.0 V Storage Temperature -40 85 C Relative Humidity 5 95 % Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the module GERERAL OPERATING CHARACTERISTICS Parameter Symbol Min. Typ Max. Unit Note Data Rate 1.25 Gb/s Supply Voltage Vcc 3.13 3.3 3.47 V Supply Current Icc5 280 ma 0 70 C DTSB35(53)12L-CD20 Operating Case Temp. Tc -10 80 C DTSB35(53)12L-ED20-40 85 C DTSB35(53)12L-ID20 ELECTRICAL INPUT/OUTPUT CHARACTERISTICS Transmitter Parameter Symbol Min. Typ Max. Unit Note Diff. input voltage swing 120 820 mvpp 1 Tx Disable input Tx Fault output H VIH 2.0 Vcc+0.3 L VIL 0 0.8 H VOH 2.0 Vcc+0.3 L VOL 0 0.8 Input Diff. Impedance Zin 100 Ω V V 2 Receiver Parameter Symbol Min. Typ Max. Unit Note Diff. output voltage swing 340 650 800 mvpp 3 H VOH 2.0 Vcc+0.3 V Rx LOS Output L VOL 0 0.8 Note 1) TD+/- are internally AC coupled with 100Ω differential termination inside the module. 2

Note 2) Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V. Note 3) RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES. OPTICAL CHARACTERISTICS Transmitter arameter Symbol Min. Typ Max. Unit Note 1270 1310 1360 Operating Wavelength λc nm 1500 1550 1570 Ave. output power (Enabled) Po -8-4 dbm 1 Extinction Ratio ER 9 db 1 RMS spectral width Δλ 3.5 nm Rise/Fall time (20%~80%) Tr/Tf 0.26 ps 2 Output Eye Mask Telcordia GR-253-CORE and ITU-T G.957 compatible Note (1): Measure at 2^7-1 NRZ PRBS pattern Note (2): Transmitter eye mask definition Receiver Parameter Symbol Min. Typ Max. Unit Note 1530 1550 1570 1270 1310 1360 nm Sensitivity Psen -25 dbm 3 Operating Wavelength Min. overload Pimax -3 dbm LOS Assert Pa -35 dbm LOS De-assert Pd -26 dbm LOS Hysteresis Pd-Pa 0.5 6 db Note 1) Measured at 10.3125b/s with PRBS 2 31 1 NRZ test pattern. Note 2) 20%~80% Note 3) Under the ER worst case, measured at 10.3125 Gb/s with PRBS 2 31-1 NRZ test pattern for BER < 1x10-12 Digital Diagnostic Functions Datocom DTSB35(53)12L-CD20 transceivers support the 2-wire serial communication protocol as defined in the SFP MSA. It is very closely related to the E2PROM defined in the GBIC standard, with the same electrical specifications.

The standard SFP serial ID provides access to identification information that describes the transceiver s capabilities, standard interfaces, manufacturer, and other information. Additionally, Datocom SFP transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range. The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a 2-wire serial interface at the 8bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backward compatible with both the GBIC Specification and the SFP Multi Source Agreement. The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. Digital diagnostics for the DTSB35(53)12L-CD20 are Internally calibrated by default. Pin Definitions and Functions

Note 1) The module ground pins shall be isolated from the module case. Note 2) This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board. Note 3) This pin shall be pulled up with 4.7K-10Kohms to VccT in the module. Note 4) This pin is an open collector/drain output pin and shall be pulled up with 4.7K-10Kohms to Host_Vcc on the host board. In FC designated as RX_LOS, insonet designated as LOS, and in Ethernet designated at Signal Detect. TYPICAL INTERFACE CIRCUIT

Recommended power supply filter Note: Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 ma greater than the steady state value PACKAGE DIMENSIONS

FOR MORE INFORMATION DATOLINK Ltd Add: 0811,Rujun Building, AV.Banxuegang, Bantian, Longgang District,Shenzhen,China 518129 Tel: 86-755-25263582 25263585 Fax:86-755-28367056 Email: sales@datolink.com Website:www.datocom.com