Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC
|
|
|
- Allan Shaw
- 9 years ago
- Views:
Transcription
1 Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC John Crow,, IBM Watson Research Center, Dan Kuchta,, IBM Watson Research Center, Mounir Meghelli,, IBM Watson Research Center, Petar Pepeljugoski,, IBM Watson Research Center, Israel Ury,, Ortel Corporation,
2 Features of Low Cost High Speed ICs (SiGe and CMOS) are Less Expensive than OE Chips Uncooled Optics for LAN spans Adapt Technology from Multiple, Existing Suppliers Transceivers developed by many suppliers Capitalize on high BW MMF's; & existing SMF cable suppliers Multiple IC Foundries Extensions of Existing Standard Serial Package Technology User Familiarity with TDM 1 GbE, FCS Can use existing LAN installation methodology/infrastructure
3 Objectives of These Presentations IBM Presentation Demonstration of a serial optical link prototype exceeding the requirements of 10 GbE, 10 km, LAN, PHY Relates this link technology to Extensions of the 1 GbE Tables of Link and Transmitter / Receiver Specifications Ortel Presentation Presents Data Supporting Manufacturability
4 Link Demonstration Stressed the 12.5Gbd/10km option: operated at 13 Gbd, 14 km Ortel Transmitter and Receiver Modules IBM SiGe Clock & Data Recovery IC Ortel Tx Ortel Rcv Receiver Output 'eye" Recovered Data and Clock
5 Link Components Transmitter Ortel DFB laser with isolator Driven by Pattern Generator with bias conditions tested, near I th for high extinction and to stress jitter 12.5 Gbaud and 13.0 Gbaud tested Receiver Ortel PD with preamp External AC coupled post-amp for 200 mv pp to CDR IC Clock and data recovery IC (CDR) SiGe BiCMOS from IBM Foundry, f t > 45 GHz (HBT), 0.5 mm (CMOS) Single chip CDR, V Designed for 12.5 Gbaud
6 Long Wavelength Transmitter Characteristics (extension of IEEE 802.3z Table 38.7) Description Current Link Stressed Measurements Tentative Spec. Unit Signaling speed GBd Wavelength nm τ rise /τ fall (20-80%) 14.6 ps / 31 ps 25 ps Spectral width nm, cw Launch power (max) dbm, avg. Launch power (min) -4 dbm, avg. Extinction Ratio(min) 10 6 db RIN db/hz SMSR db
7 Long Wavelength Receiver Characteristics (extension of IEEE 802.3z Table 38.8) Description Current Link Stressed Measurements Tentative Spec. Unit Signaling Speed GBd Wavelength nm Receiver power (max) Receiver power (min) dbm,avg BER dbm,avg Return loss dbm
8 Worst case link power budget & penalties (extension of IEEE 802.3z Table 38.9) Long Wavelength Description Current Link Tentative Spec. Unit Measurement SMF-DFB Modal Bandwidth N/A N/A MHz*km Link power budget db Operating distance km Channel insertion loss db Link power penalties db Unallocated margin db
9 Link Jitter Budget (extension of IEEE 802.3z Table 38-10) TP1 TP2 TP3 TP4 PMA T- T+ Optical Transmit- Patch Cord Optical Receiver R- R+ PMA Fiber Optic Cable (Channel) Table 38-10,802.3z Figure 1. Definition of jitter test points. Deterministic Jitter, UI Total Jitter, UI TP TP1 to TP TP TP2 to TP TP TP3 to TP Does jitter just scale according to UI? Initial measurements made on one link at 12.5 Gbaud. TP
10 Link Jitter Budget (cont.) (extension of IEEE 802.3z Table 38-10) Deterministic Jitter Scaled from 1GbE (psec) Deterministic Jitter measured (psec) 1 s of RJ ( TP1 8 7 TP TP TP DJ,RJ difficult to measure/correlate to TP's, but overall RJ,TJ looks manageable. Link driven close to I th to enhance jitter Used run length (~8B/10B) Might be worse at 10 Gbaud and with long run length codes Jitter Budget allocation to be resolved by 802.3ae sub-group
11 Implications of Link Demonstration 10 Gigabit/sec links with 12.5 Gbaud signaling rates are feasible Allows robust codes for reliable link operation Compatible with 1 GbE and FCS standards. Optical Transceiver Products From Current Production can be adapted to 10 GbE LAN Requirements Elimination of cooling allows migration to smaller, lower power, lower cost Transceiver Modules SiGe BiCMOS From Foundry can provide CDR function as IC All high speed functions? In single IC? This Demonstration Supports the Group Claim of a Volume Manufacturable, Low Cost PHY Technology
Dispersion penalty test 1550 Serial
Dispersion penalty test 1550 Serial Peter Öhlen & Krister Fröjdh Optillion Irvine, January 2001 Dispersion penalty test, 1550 serial Page 1 SMF Transmission at 1550 nm Different from multi-mode transmission
Golden test for dispersion penalty 1550 Serial
Golden test for dispersion penalty 1550 Serial Peter Öhlen, Krister Fröjdh (Optillion) Tampa, November 2000 Golden test for dispersion penalty, 1550 serial Page 1 SMF Transmission at 1550 nm Different
LONGLINE 10Gbps 10km SFP+ Optical Transceiver
LONGLINE 10Gbps 10km SFP+ Optical Transceiver Features Optical interface compliant to IEEE 802.3ae 10GBASE-LR Electrical interface compliant to SFF-8431 Hot Pluggable 1310nm DFB transmitter, PIN photo-detector
Intel Ethernet SFP+ Optics
Product Brief Intel Ethernet SFP+ Optics Network Connectivity Intel Ethernet SFP+ Optics SR and LR Optics for the Intel Ethernet Server Adapter X520 Family Hot-pluggable SFP+ footprint Supports rate selectable
10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance
Feature 10Gb/s serial optical interface compliant to 802.3aq 10GBASE-LRM Electrical interface compliant to SFF-8431 specifications for enhanced 8.5 and 10 Gigabit small form factor pluggable module SFP+
SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW
Product Features Compliant with IEEE Std 802.3-2005 10G Ethernet 10GBase-LR/LW Electrical interface specifications per SFF-8431 Management interface specifications per SFF-8431 and SFF-8472 SFP+ MSA package
How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (
Features 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX Supports 9.95Gb/s to 10.3Gb/s data rates Simplex LC Connector Bi-Directional SFP+ Optical Transceiver Single
10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX
Features 10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX Supports 9.95Gb/s to 10.5Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 10km with SMF 1270/1330nm
Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL
Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL PRODUCT FEATURES Hot-pluggable XFP footprint Supports 8.5Gb/s and 9.95 through 10.5Gb/s* bit
8.5Gb/s SFP+ Fibre Channel Optical Transceiver
8.5Gb/s SFP+ Fibre Channel Optical Transceiver Features Up to 8.5Gb/s bi-directional data links Hot Pluggable SFP+ footprint Built-in digital diagnostic functions 1310nm FP laser transmitter Duplex LC
2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX
2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX Features Support 2.488Gbps data links 1490nm DFB laser and PIN photodetector for 20km transmission 2xBi-directional transceivers
How To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
LONGLINE 40km XFP Optical Transceiver
LONGLINE 40km XFP Optical Transceiver Features XFP MSA Rev 4.5 Compliant Data rate from 9.95Gbps to 11.3Gbps No Reference Clock required Cooled 1550nm EML and PIN receiver link length up to 40km +1.8V,+3.3V,+5V
SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX 1.0625Gb/s Fiber Channel
Product Features Compliant to IEEE Std 802.3-2005 Gigabit Ethernet 1000Base-SX, with DOM Specifications according to SFF-8074i and SFF-8472, revision 9.5 Digital Diagnostic Monitoring 850nm Vertical Cavity
CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:
DATA SHEET CISCO DWDM XENPAK OVERVIEW The Cisco Dense Wavelength-Division Multiplexing (DWDM) XENPAK pluggable allows enterprise companies and service providers to provide scalable and easy-to-deploy 10
CISCO 10GBASE X2 MODULES
DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity
Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics
Fast Ethernet 00BASE-0 SFP Single Mode Transceivers with Digital Diagnostics TXAGM Single Mode Product Description The TXAGM SFP series of multi-rate fiber optic transceivers with integrated digital diagnostics
10GBASE -LRM, 220m Reach GX2-31192-LRMC
Features Compatible with X2 MSA Rev2.0b 10GBASE -LRM, 220m Reach GX2-31192-LRMC Support of IEEE 802.3ae 10GBASE-LR at 10.3125Gbps Transmission Distance up to 220m(MMF) SC Receptacle 1310nm DFB Laser SC
DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver
产 品 规 格 书 Product Specification Sheet DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver PRODUCT FEATURES Up to 1.25Gb/s data links FP laser transmitter for DTSB35(53)12L-CD20
LONGLINE 2km XFP Optical Transceiver
LONGLINE 2km XFP Optical Transceiver Features Supports 9.95Gb/s to 11.1Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 2km with SMF 1310nm FP laser XFP MSA package with duplex LC connector
X2 LR Optical Transponder, 10Km Reach
X2 LR Optical Transponder, 10Km Reach Features Compatible with X2 MSA Rev2.0b Support of IEEE 802.3ae 10GBASE-LR at 10.3125Gbps Transmission Distance up to 10km(SMF) SC Receptacle 1310nm DFB Laser SC Duplex
1.25Gbps GBIC Optical Transceiver, 20km Reach
1.25Gbps GBIC Optical Transceiver, 20km Reach Features Dual data-rate of 1.25Gbps/1.0625Gbps operation 1310nm FP laser and PIN photodetector for 20km transmission Duplex SC optical interface Standard serial
Multi-Gigabit Interfaces for Communications/Datacomm
Multi-Gigabit Interfaces for Communications/Datacomm Richard Dugan, Drew Plant Hewlett-Packard Integrated Circuit Business Division email: [email protected], [email protected] 802.3 Meeting, Austin
DWDM SFP Series. Power budget* (note2) Laser
EOLS-1606-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 622Mbps Available in all C-Band Wavelengths
4.25Gbps SFP Optical Transceiver, 30km Reach
4.25Gbps SFP Optical Transceiver, 30km Reach Features Single 3.3 V supply Supports 1.0625/2.125/4.25Gb/s Fiber Channel Operation Gigabit Ethernet compatible 1310nm DFB Laser SFP MSA SFF-8074i compliant
Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL
Product Specification OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver FTLF1422P1xTL PRODUCT FEATURES 622 Mb/s bi-directional data links Hot-pluggable SFP footprint Built-in digital diagnostic
SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.
SO-QSFP28-LR4 QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW The SO-QSFP28-LR4 is a 100 Gbps transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of
Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?
Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? GBE, as the name says, is Ethernet scaled up to gigabit speeds, providing a migration path from Ethernet at 10 MB/s to Fast Ethernet at 100 MB/s
155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX
Features 155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX 1310nm FP laser and PIN photodetector for 40km transmission Compliant with SFP MSA and SFF-8472 with simplex
155Mbps DFB SFP Optical Transceiver, 120km Reach
155Mbps DFB SFP Optical Transceiver, 120km Reach Features Data-rate of 155Mbps operation DFB 1550nm wavelengths laser and PIN photo detector for 120km transmission Compliant with SFP MSA and SFF-8472 with
Attaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.
Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
DWDM SFP Series. Power budget* (note2) Laser
EOLS-1624-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 2.5Gbps Available in all C-Band Wavelengths
SFP Transceiver Specifications
APPENDIXB This appendix provides cabling specifications for the SFP transceivers supported on the Cisco ME 60 Ethernet switch. Figure B-1 shows an optical SFP transceiver with the major features labeled.
Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features
Description The Light Link Series 2 optical transmitter model employs a high performance thermally stabilised, DFB, low-chirp, isolated laser to transmit CATV signals. Operating on a specific optical wavelength
The 10G Ethernet Link Model
The 10G Ethernet Link Model Piers Dawe Agilent Technologies Los Angeles, October 2001 What is it? A spreadsheet with equations Runs in Excel Can be populated with parameter values to represent different
XFP Optical Receiver, 80km Reach
Features Supports 9.95Gb/s to 11.1Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 80km with SMF APD ROSA receiver XFP MSA package with duplex LC connector No reference clock required
Introduction to Optical Link Design
University of Cyprus Πανεπιστήµιο Κύπρου 1 Introduction to Optical Link Design Stavros Iezekiel Department of Electrical and Computer Engineering University of Cyprus HMY 445 Lecture 08 Fall Semester 2014
Product Specification 10Gb/s BIDI SFP+ Transceiver
PRODUCT FEATURES Up to 10.7Gbps Data Links Product Specification 10Gb/s BIDI SFP+ Transceiver Single Mode LC Receptacle Bi-directional Transceiver Up to 20km transmission on SMF Power dissipation
Your Network. Our Connection. 10 Gigabit Ethernet
Your Network. Our Connection. 10 Gigabit Ethernet t Agenda Why 10G? Applicable 10GbE Standards Distance Restrictions Copper Fiber Fiber Repeaters 3R s Fiber Module Types Form Factors of 10G modules Future
Designing Fiber Optic Systems David Strachan
Designing Fiber Optic Systems David Strachan Everyone knows that fiber optics can carry a huge amount of data. There are more benefits to using fiber optics in broadcast applications than you might realize.
PCI Express: The Evolution to 8.0 GT/s. Navraj Nandra, Director of Marketing Mixed-Signal and Analog IP, Synopsys
PCI Express: The Evolution to 8.0 GT/s Navraj Nandra, Director of Marketing Mixed-Signal and Analog IP, Synopsys PCIe Enterprise Computing Market Transition From Gen2 to Gen3 Total PCIe instances. 2009
10GBASE-LR XFP Optical Transceiver AXM752
350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: [email protected] www.netgear.com 10GBASE-LR XFP Optical Transceiver AXM752 10GBASE-LR XFP Optical Transceiver Pb FEATURES
8B/10B Coding 64B/66B Coding
8B/10B Coding 64B/66B Coding 1. Transmission Systems 2. 8B/10B Coding 3. 64B/66B Coding 4. CIP Demonstrator Test Setup PeterJ Slide 1 Transmission system General Data Clock D C Flip Flop Q @ 1 Gbps = 1
SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609
Features Applications 10 Gigabit Ethernet (10.3125Gbps) 10 Gigabit Fiber Channel (10.51875Gbps) SFP+ Type DWDM Dual LC Transceiver EML Laser PIN Photo Detector 40Km transmission with SMF 3.3V dual power
1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet
1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet 3.3V: GBIC-1250A4FS (500m) GBIC-1250B4QS (10km) 5V: GBIC-1250A3FS (500m) GBIC-1250B3QS (10km) Features Compliant with
Dual Fiber SFP Series
SFP-ZX, EZX and XZX series SFP Single-Mode, Dual Fiber Transceiver for 1.25Gbps FC/GBE Features Up to 4.25Gbps Data Rate 1550nm DFB 80km with 9/125 µm SMF 120km with 9/125 µm SMF 160km with 9/125 µm SMF
SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION
SO-CFP-ER4-DWDM CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20 km SO-CFP-ER4-DWDM OVERVIEW The SO-CFP-ER4-DWDM is a 100G transceiver module supporting 100GBASE-LR4 and OTU4 applications over singlemode (SM)
Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description
Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description Modultech OTN XFP DWDM transceiver combines carrier grade OTN G.709 and FEC performance into a XFP MSA
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer [email protected] Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards Optical Fiber
Cisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
Optical Communications Analysis of transmission systems. Henrique Salgado [email protected]. Point-to-point system
Optical Communications Analysis of transmission systems 2007-2008 Henrique Salgado [email protected] 1 Point-to-point system The project of a point-to-point link involves, in general, many interrelated
Prisma IP 10 GbE VOD Line Card
Digital Transport Prisma IP 10 GbE VOD Line Card Description The Prisma IP 10 GbE Line Card family of products consists of Transmitter (OTX), Receiver (ORX), and Transceiver (OTR) modules. These modules
Georgia Tech 100G Center
Georgia Tech Industry-University 100G Networking Center Stephen E Ralph Prof of Electrical and Computer Engineering [email protected] School of Electrical and Computer Engineering Georgia Tech
Migration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
Fibre Channel Fiber Cabling
OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug
Simulation and Best Design of an Optical Single Channel in Optical Communication Network
International Arab Journal of e-technology, Vol., No., June 11 91 Simulation and Best Design of an Optical Single Channel in Optical Communication Network Salah Alabady Computer Engineering Department,
GBIC CWDM 40km Part no: 70257-70264
GBIC CWDM 40km Part no: 7025770264 Description General The GBIC CWDM 40 transceiver is small form factor pluggable module with standard SC duplex connector for fiber communications. This module is designed
Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance
Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance Page 1 Agenda Introduction PCIe 2.0 changes from 1.0a/1.1 Spec 5GT/s Challenges Error Correction Techniques Test tool
Advanced Modulation Formats in Data Centre Communications Michael J. Wale Director Active Products Research
Advanced Modulation Formats in Data Centre Communications Michael J. Wale Director Active Products Research 2 nd Symposium on Optical Interconnects in Data Centres ECOC, Cannes, 23rd September 2014 1 2014
Plastic Optical Fiber for In-Home communication systems
Plastic Optical Fiber for In-Home communication systems Davide Visani 29 October 2010 Bologna E-mail: [email protected] Summary Reason for Fiber in the Home (FITH) FITH scenario Comparison of CAT5
Enabling the Business Continuity & Change the way business communicates www.lightron.co.kr
Enabling the Business Continuity & Change the way business communicates www.lightron.co.kr Products Selection Guide for Two- Form Data Rate Distance Connector Product P/N LD / PD DDM Temp. RoHS Optic Innovation!
Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet
Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet Features Dual data-rate of 1.25Gbps/1.063Gbps operation 1550nm DFB
Network Topologies and Distances
Network Topologies and Distances Chris Di Minico MC Communications [email protected] 1 Presentation objectives Considerations for 802.3ba fiber link distance objectives 2 HSSG Objectives Support full-duplex
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of
With the advent of Gigabit Ethernet
INTERNATIONAL JOURNAL OF NETWORK MANAGEMENT Int. J. Network Mgmt 2001; 11:139 146 (DOI: 10.1002/nem.396) The importance of modal bandwidth in Gigabit Ethernet systems By David N. Koon Ł This article deals
Trends In Data Rate And Link Length In Evolving Optical Standards
Trends In Data Rate And Link Length In Evolving Optical Standards David Cunningham 22 nd September 2013 Outline Building and Data Centre link lengths Trends for standards-based electrical interfaces Data
Optical transmission systems over Plastic Optical Fiber (POF) at high bit rate
Optical transmission systems over Plastic Optical Fiber (POF) at high bit rate Politecnico di Torino, 13 Sept. 2007 Daniel Cárdenas OptCom Group Photonlab Dipartimento di Elettronica Politecnico di Torino
Recent developments in high bandwidth optical interconnects. Brian Corbett. www.tyndall.ie
Recent developments in high bandwidth optical interconnects Brian Corbett Outline Introduction to photonics for interconnections Polymeric waveguides and the Firefly project Silicon on insulator (SOI)
Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network
Optical Fiber Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Carl Roberts [email protected] Cabling considerations for DCs and
SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver
Product Features Up to 1.25Gb/s bi-directional data links SFP form with compact RJ-45 connector +3.3V single power supply 0 to 70 o C operating case temperature Intelligent Auto-Negotiation support for
Preparing Infrastructure for 10 Gigabit Ethernet Applications
Preparing Infrastructure for 10 Gigabit Ethernet Applications Christopher T. Di Minico, Cable Design Technologies (CDT) Corporation, Bruce Tolley, Cisco Systems Background The Internet will continue to
5 PMD Proposal and 850 nm Serial Specifications and Criteria. List of Supporters
5 PMD Proposal and 850 nm Serial Specifications and Criteria Presented By Paul Kolesar, Lucent Technologies July 10-13, 2000 IEEE 802.3ae Plenary Meeting, La Jolla 1 List of Supporters 63 Individuals,
LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13
LONGLINE QSFP+ SR4 Features 4 channels full-duplex transceiver modules Transmission data rate up to 10.5Gbps per channel 4 channels 850nm VCSEL array 4 channels PIN photo detector array Low power consumption
DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage
DATA CENTER APPLICATIONS REFERENCE GUIDE Scope This technical paper provides an overview about the most dominant networking and storage applications in modern data centers. Additionally, it offers information
10GBASE-SR XFP Optical Transceiver AXM751
350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: [email protected] www.netgear.com 10GBASE-SR XFP Optical Transceiver AXM751 10GBASE-SR XFP Optical Transceiver FEATURES
A Gigabit Transceiver for Data Transmission in Future HEP Experiments and An overview of optoelectronics in HEP
A Gigabit Transceiver for Data Transmission in Future HEP Experiments and An overview of optoelectronics in HEP Ken Wyllie, CERN 1 Outline Optoelectronics What? Why? How? Experience in HEP (LHC) & future
1000BASE-BX-OLT Transceiver
SFP BIDI, Single LC Connector, 1490nm DFB LD for Single Mode Fiber, ohs Compliant Features 1490nm DFB LD Multi Data ate: from 125M to 1.25Gbps, NZ Single +3.3V Power Supply ohs Compliant and Lead-free
Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems
Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems Data Center Environment Data Center Environment Higher speeds Higher density
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
Product Specification. +3200 ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx
Product Specification +3200 ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx PRODUCT FEATURES Supports 10.7Gb/s to 11.35Gb/s -500 to +3200 ps/nm Dispersion Tolerance (~200km reach without dispersion
GPON OLT Optical Transceiver SFP Module RTXM167-526. Features
GPON OLT Optical Transceiver SFP Module RTXM167-526 Features Integrated Single fiber bi-directional optical subassembly 1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with
HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable
Overview Models HP 0.5 m Multimode OM3 LC/LC Optical Cable HP 1 m Multimode OM3 LC/LC Optical Cable HP 2 m Multimode OM3 LC/LC Optical Cable HP 5 m Multimode OM3 LC/LC Optical Cable HP 15 m Multimode OM3
Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers
HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers Data Sheet SERCOS SERCOS is a SErial Realtime COmmunication System, a standard digital interface for communication between controls and drives
PCI-SIG ENGINEERING CHANGE NOTICE
PCI-SIG ENGINEERING CHANGE NOTICE TITLE: Separate Refclk Independent SSC Architecture (SRIS) DATE: Updated 10 January 013 AFFECTED DOCUMENT: PCI Express Base Spec. Rev. 3.0 SPONSOR: Intel, HP, AMD Part
Wavelength Division Multiplexing
WDM Wavelength Division Multiplexing -CWDM vs DWDM- Fargo, ND 1 Agenda 1. Overview 2. Fiber Cable WDM Characteristics 3. CWDM Course WDM 4. DWDM Dense WDM 5. Applications Best Fit- Future? 6. Summary Fargo,
Modeling and Performance Analysis of DWDM Based 100 Gbps Low Power Inter-satellite Optical Wireless Communication (LP-IsOWC) System
ISSN(Print): 2377-0538 ISSN(Online): 2377-0546 DOI: 10.15764/STSP.2015.01001 Volume 2, Number 1, January 2015 SOP TRANSACTIONS ON SIGNAL PROCESSING Modeling and Performance Analysis of DWDM Based 100 Gbps
Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure
Data Center Optimization: Component Choice and Innovative Design Combine to Allow the Creation of an Enabling Infrastructure Data Center Spaces Data Center Spaces as Defined by the TIA 942 Standard Source:
Understanding Ethernet and Fibre Channel Standard-Based Test Patterns An explanation of IEEE 802.3 and NCITS standard test patterns By Todd Rapposelli
White Paper Understanding Ethernet and Fibre Channel Standard-Based Test Patterns An explanation of IEEE 802.3 and NCITS standard test patterns By Todd Rapposelli Overview The IEEE 802.3 standards for
Implementation of Short Reach (SR) and Very Short Reach (VSR) data links using POET DOES (Digital Opto- electronic Switch)
Implementation of Short Reach (SR) and Very Short Reach (VSR) data links using POET DOES (Digital Opto- electronic Switch) Summary POET s implementation of monolithic opto- electronic devices enables the
Pericom PCI Express 1.0 & PCI Express 2.0 Advanced Clock Solutions
Pericom PCI Express 1.0 & PCI Express 2.0 Advanced Clock Solutions PCI Express Bus In Today s Market PCI Express, or PCIe, is a relatively new serial pointto-point bus in PCs. It was introduced as an AGP
155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1
155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1 Application Note 1125 RCV1551, RGR1551 Introduction This application note details the operation and usage of the RCV1551 and RGR1551 Light to
The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper
The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper Optical Fiber WP1150 Issued: October 2007 Supersedes: October 2006 ISO 9001 Registered
The ABC of Direct Attach Cables
The ABC of Direct Attach Cables Thomas Ko, RCDD Product Manager TE Connectivity Network Speed and Technology 10/40/100 Gbps the transition is occurring right now What are Customers Saying about their 10/40/100
Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT. www.methode.com
DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT QSFP+ MSA compliant Hot-pluggable footprint Supports Digital Serial ID and User Memory Robust Die Cast Housing Small footprint to maximize port spacing
Optimux-134, Optimux-125
Data Sheet Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 25/34 Mbps or 125/134 Mbps operation s Single-,
Cisco 10GBASE SFP+ Modules
Data Sheet Cisco 10GBASE SFP+ Modules A broad range of industry-compliant SFP+ modules for 10 Gigabit Ethernet deployments in diverse networking environments Product Overview The Cisco 10GBASE SFP+ modules
