Thermo Scientific ConFlo IV Universal Interface



Similar documents
Thermo Scientific SIEVE Software for Differential Expression Analysis

Thermo Scientific ExactFinder Software

Thermo Scientific irm-gc/ms Technology

Getting Answers at the Source Requires a New Way of Thinking About Software

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

LC-MS/MS Solutions for the Pharmaceutical and CRO Industries TSQ Series -based Solutions for Drug Discovery and Development

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

LIFECYCLE. Thermo Scientific. Enterprise Solutions

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

WATERS QUANTITATIVE ANALYSIS solutions

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Thermo Scientific Qtegra Intelligent Scientific Data Solution Software. Delivering quality. Driving productivity

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

[ Care and Use Manual ]

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Finnigan ELEMENT2. High Performance High Resolution ICP-MS

How To Control A Record System

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS

SCION SQ Series GC-MS

Elemental analyzer multi EA 5000

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

ProteinChip Energy Absorbing Molecules (EAM)

On-line Dissolved Gas Analysis

A Complete Solution for Method Linearity in HPLC and UHPLC

QGA Quantitative Gas Analyser

CHROMOCTANE O N LINE ANALYZER

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Agilent 4338B Milliohm Meter

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

FT-NIR for Online Analysis in Polyol Production

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

GC-xt. The most flexible GC /GC-MS liquid sample injector

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

What is Eluent Generation?

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

23 The Thermal Conductivity Detector

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Agilent Television Power Consumption Testing. Application Note

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

Customer Support. Superior Service Solutions for Your Laser and Laser Accessories. Superior Reliability & Performance

AMD Analysis & Technology AG

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

XFA 600 Thermal Diffusivity Thermal Conductivity

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

The Sievers 900 Series TOC Analyzers

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Continuous flow direct water heating for potable hot water

Agilent E6832A W-CDMA Calibration Application

Agilent 87421A/87422A Power Supply

Chemical Measurement Solutions

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

Fiscal Measurement Natural Gas

Gas Chromatography Liner Selection Guide

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

EnAlgae SOP: Biogas analysis

Optimize Your Process Operations by Improving Process Monitoring

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

MILESTONE H E L P I N G C H E M I S T S

How many students study abroad and where do they go?

DMA-1 Direct Mercury Analyzer

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Agilent 7697A Headspace Sampler Data Sheet

Oilfield Services Measurement Solutions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Agilent 4339B/4349B High Resistance Meters

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Appendix 5 Overview of requirements in English

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Get the benefits of Norgren s unique range of Online services

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Name of presenter Title. Date

Transcription:

m a s s s p e c t r o m e t r y Thermo Scientific ConFlo IV Universal Interface The Universal Interface Part of Thermo Fisher Scientific

ConFlo IV Universal Interface The Universal Interface The development of Continuous Flow carrier gas assisted techniques has dominated the growth of Isotope Ratio Mass Spectrometry for the last two decades with the series of our ConFlo interfaces. Now we have developed the Thermo Scientific ConFlo IV, the first universal Continuous Flow interface, which allows simultaneous attachment of multiple sample preparation devices with different carrier gas flow regimes to the same Isotope Ratio MS. Unique Features of the New ConFlo IV : Powerful new features of the ConFlo IV Universal Interface include intelligent connection to all necessary reference gases, automatic sample size recognition, sample and reference signal matching and self-diagnosis. The ConFlo IV takes significant steps towards full automation of the stable isotope laboratory, maximizing system utilization and uptime. Flash EA Higher sample throughput and less idle time Continuous and unattended analysis utilizing 3 preparation devices Software controlled standby and startup of Trace GC and Flash EA smartea Mode: Automatic detection and adjustment of sample gas to reference gas intensities Computer-controlled auto-dilution of sample gases based on TCD signals from the EA TC/EA Five reference gases always available Sample analysis and referencing of all CNOHS species in a batch sequence Lowest consumption of reference gases Computer-controlled reference gas intensities Auto-determination of linearity, stability, and H 3+ factor Integrated system monitoring and self-diagnosis Surveyor with LC IsoLink DELTA V

ConFlo IV Universal Interface TRACE GC Ultra GasBench MAT 253 Several thousand Continuous Flow preparation devices are in use with existing Isotope Ratio MS, most of which have more than one preparation device. The Thermo Scientific ConFlo IV Universal Interface optimizes the utilization of the Isotope Ratio MS by handling the switch between preparation devices, including activation and deactivation as well as change of reference gases. Preparation units can be regenerated and loaded while others are in operation. The switch between applications can take place at any time without operator assistance. System parameters sensitive to data quality can be automatically checked within all sample sequences. The ConFlo IV is the first universal interface which implements the fundamental principal of Dual Inlet Isotope Ratio MS: identical treatment of sample and standard. Intensities of the transient sample and reference gas signals in a He carrier gas stream can now be matched, leading to improved precision and reliability.

ConFlo IV Universal Interface Principle of IRMS The measurement of isotope ratios requires that a sample gas is measured relative to a reference gas of a known isotope ratio. Signal intensities of reference and sample gas should be matched as closely as possible in order to achieve the best quality of data. The Thermo Scientific ConFlo IV matches the sample and the reference gas signals for highest precision and long term performance. smartea The First Intelligent EA-IRMS Flexible computer controlled auto-dilution of sample gases based on TCD signals Auto-Dilution Because there is considerable variability in nature in the relative amounts of C/N/S and H/O, and because the ionization efficiencies of the analyte species differ significantly, Continuous Flow sample preparation leads to a very dynamic range of signal intensities. The ConFlo IV is designed to handle this large and variable dynamic range of elements and isotopes using patented He-dilution technology*. The dilution happens in the open split, at the very last point before transfer into the ion source, eliminating any possible isotopic effects on the sample gas. *Patent US 5,424,539 smartea Mode The combination of ConFlo IV and FlashEA builds the first intelligent EA-IRMS system. In the smartea mode the Thermo Scientific FlashEA reports the TCD (Thermal Conductivity Detector) responses to the Isodat software, which calculates the optimal dilution for each gas species in the sample. The ConFlo IV applies the dilution to each gas species matching sample and reference gas intensities. Result: Automatically adjusted Isotope Ratio MS signals

Reference Gas Injection For the purpose of sample-standard referencing in Continuous Flow applications, cylinders of calibrated reference gases can be used for extended periods of time. Reference gases are supplied in µl amounts through inert capillaries into the Reference Gas injection port, creating a rectangular, flat-topped peak of reference gas without changing any pressures or gas flows. The use of reference gases instead of reference bulk material for standardization reduces the operational costs by almost 50 % while increasing the sample throughput by almost 50 %. The reference gas consumption is negligible and thus gases can be kept trickling continuously, ensuring constant conditions in the supply lines and pressure regulators. Automatic Range Control The ConFlo IV provides automated adjustment of the intensities of the reference gas pulses. As a consequence, and for the first time in Continuous Flow Isotope Ratio MS, the reference gas intensities can be matched to the intensities of sample gas pulses. Hence, the fundamental principle of Isotope Ratio MS, equal conditions for sample and reference gases, can be applied to all Continuous Flow applications. Automatic adjustment of reference gas intensities Integrated detection and evaluation of TCD signals Automatic adjustment of sample gas intensities based on TCD signal information Determination of Isotope Ratios System Monitoring & Self Diagnosis The ConFlo IV is designed to enable unattended operation of the Thermo Scientific Isotope Ratio MS over a long series of sequences utilizing different preparation systems. In such a scenario it is advantageous to determine system parameters such as stability, isotope linearity, and H 3+ factor prior to the automatic start of a new application. The ConFlo IV applies these tests including storage, evaluation, and application of the determined parameters. For the first time in Continuous Flow applications a fast and automated monitoring of system parameters is possible.

ConFlo IV Universal Interface Multiple Preparation Devices Multiple Inlet Control Multiple preparation and inlet devices can operate within the same batch of sequences with the Thermo Scientific ConFlo IV Universal Interface, allowing continuous and unattended sample analysis. Additional samples can be uploaded and appended to the batch of sequences without any interruption of the actual data acquisition. More samples can be added to the active preparation device or even a complete new application can be set up on a separate device and appended, waiting for completion of the actual analyses. The next device will then automatically be activated and diagnosed for the next application while the other device will be set to idle or standby. System parameters important to the performance and integrity of data, such as system stability, signal linearity and the H 3+ factor, can be monitored automatically at any time before, after and even within sample sequences. As an example, the H 3 + factor could be measured several times. Each H 3+ factor is stored in the history log file to be used for the next δd analysis. Continuous Sample Analysis Sample upload and sequence extension during analysis Switch between preparation devices without operator attendance System parameter monitoring at any part of the sequence Five reference gases always available Stand-by and reactivation of Thermo Scientific TRACE GC Ultra and Flash EA Multi Element System: One Interface - Five Elements CNOHS Amplitude [mv] 7000 δ 15 N N 2 δ 13 C CO 2 δ 34 S SO 2 6000 5000 4000 3000 2000 1000 0 0 200 400 600 800 1000 1200 1400 Time [s] Amplitude [mv] 7000 6000 5000 4000 3000 2000 1000 0 δ 2 H H 2 δ 18 O CO 0 50 100 150 200 250 300 Time [s]

One Interface: ConFlo IV Multi Element System δ 13 C, δ 15 N and δ 34 S from one EA and δd and δ 18 O from one TC/EA analysis The combination of a dynamic flash combustion elemental analyzer (EA) with a high temperature conversion elemental analyzer (TC/EA) can measure δ 13 C, δ 15 N, δ 34 S, δ 18 O and δd. The ConFlo IV controls the five reference gases required for such analysis, saving time and money. The wide dynamic range to be expected in elemental compositions is addressed by the ConFlo IV s unique auto-dilution system. Water Analysis System δ 2 H and δ 18 O from Equilibration with the Thermo Scientific GasBench and from High Temperature Conversion with the Thermo Scientific TC/EA The versatile combination of TC/EA and GasBench II allows high throughput and high precision isotopic analysis of small water samples. The TC/EA quantitative high temperature C-reduction allows fast screening of δd and δ 18 O from a single injection of a water sample within less than six minutes for samples as small as 0.1 µl. The GasBench II provides highest precision δd or δ 18 O results by isotope equilibration of water samples with H 2 or CO 2 gas in the headspace. Hence it allows analyzing waters with high amounts of dissolved solids. While 96 water samples ( 200 µl) are equilibrating in the GasBench II, more than 200 water samples are screened by the TC/EA. At the end of the TC/EA analyses, system parameters can be checked automatically followed by the start of the GasBench II analyses. Both applications benefit by the flexible auto-dilution and reference gas control capabilities of the ConFlo IV. Bulk EA and CSIA Systems CSIA with GC-C/TC and Bulk Analysis with EA and TC/EA The combination of any FlashEA for Isotope Ratio MS with the Thermo Scientific GC-C/TC III allows fast and precise bulk analysis of complete samples as well as the analysis of all individual compounds in complex mixtures. The Flash EA gives the direct link between international accepted standards and reference compounds for GC-C/TC applications. The EA-GC combination exemplifies the range of possibilities that are opened up by the ConFlo IV: completely integrated device and autosampler control, acquisition and reporting of additional detector traces (TCD, FID), all range control and auto-dilution features including the smartea mode, fully integrated standby mode, and reactivation of both devices.

Thermo Scientific ConFlo IV One Interface for All Continuous Flow Isotope Ratio MS Devices The flexibility of the ConFlo IV interface combined with the power of the Isodat script language, ISL, allows the ConFlo IV to be used as an interface with any Continuous Flow sample preparation device, from Thermo Scientific or provided by the user. Some of the fully automated features of the ConFlo IV interface need direct communication with the preparation device and are therefore specific to devices from Thermo Scientific (FlashEA 1112 IRMS, FlashEA 1112 HT, Trace GC and Trace GC Ultra). The ConFlo IV can be controlled by all fiber-line based Isotope Ratio MS from Thermo Scientific, the DELTA V Plus, DELTA V Advantage, Delta Plus XP, Delta Plus Advantage and MAT 253 using the Thermo Scientific Isodat software suite. Reference Gases Used for Applications Pure nitrogen gas, N 2, carbon dioxide, CO 2, and sulfur dioxide, SO 2, are used as reference gases for δ 15 N, δ 13 C and δ 34 S determination by combustion reactions. Sulfur dioxide is applied through a heated reference injection port. Pure hydrogen gas, H 2, and carbon monoxide gas, CO, are used for δ 2 H and δ 18 O determination by high temperature conversion reactions. Elemental Analyzers Gas Chromatographs Liquid Chromatographs Multiple Loop Injection devices Gas injection and separation units with flows of 2-100 ml/min Trace Gas preconcentration devices Laser ablation and combustion devices DOC/DIC analyzers ConFlo IV Dimensions 470 x 180 x 315 mm 18.5 x 7.08 x 12.4 (w x d x h) In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50340 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 532 4752 analyze.ca@thermo.com China +86 10 5850 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Netherlands +31 76 587 98 88 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 91 657 4930 analyze.es@thermo.com Sweden / Norway / Finland +46 8 556 468 00 analyze.se@thermo.com Switzerland +41 61 48784 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. Thermo Scientific Services extends its support throughout our worldwide network of highly trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your system, we also offer certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit us at www.thermo.com. Thermo Electron (Bremen) GmbH is certified DIN EN ISO 2001:9000 2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30140_E 06/07C