BTU ANALYSIS USING A GAS CHROMATOGRAPH



Similar documents
Chromatograph Maintenance and Troubleshooting Class # 5050

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Get the Right GC for Your Industry

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Fundamentals of Gas Chromatography

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Fiscal Measurement Natural Gas

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

On-line Dissolved Gas Analysis

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

CHROMOCTANE O N LINE ANALYZER

1. Standard conditions are in. Hg (760 mm Hg, psia) and 68 F (20 C).

ANNEX I GAS MEASUREMENTS AND TESTING AT THE DELIVERY POINT. Table of Contents

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

23 The Thermal Conductivity Detector

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

Transformer Oil Gas Analysis

Fractional Distillation and Gas Chromatography

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Process Instrumentation

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Gas Laws. The kinetic theory of matter states that particles which make up all types of matter are in constant motion.

Thermal Conductivity Detector

Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015

Calculating Volatile Organic Compounds (VOC) Flash Emissions from Crude Oil and Condensate Tanks at Oil and Gas Production Sites

Fluid & Gas Properties

THE PSYCHROMETRIC CHART AND ITS USE

Blending Fuel Gas to Optimize use of Off-Spec Natural Gas

Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences

Diffusion and Fluid Flow

THE HUMIDITY/MOISTURE HANDBOOK

N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios

NGL RECOVERY PLANT: TREATER OPTIMIZATION FOR WATER AND MERCAPTAN REMOVAL

Natural gas liquids recovery from gas turbine fuel

Optimization of Natural Gas Processing Plants Including Business Aspects

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Compressor Performance

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Molar Mass of Butane

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Gas Laws. vacuum. 760 mm. air pressure. mercury

How To Make A High Co 2 Gas Blend

THE BASICS Q: What is VOC? Q: What are flashing losses/voc emissions from hydrocarbon storage tanks? - 1 -

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

INDEX GENERAL

Gas Chromatography. Gas Chromatograph

Meriam Instrument LFE Data Sheet

Precision Mass Flow Metering For CVD Applications.

The photoionization detector (PID) utilizes ultraviolet

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction

Name Class Date. In the space provided, write the letter of the term or phrase that best completes each statement or best answers each question.

NATURAL GAS EXPERIENCE

H 3 C CH 2 CH 2 CH 2 CH 2 CH 3. Copyright 2012 Nelson Education Ltd. Chapter 1: Organic Compounds 1.1-1

Fundamentals of Mass Flow Control

Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi

Lecture 35: Atmosphere in Furnaces

Dissolved Gas Analysis Guide for Transformers Filled with Beta Fluid

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Continuous flow direct water heating for potable hot water

1500XA Gas Chromatograph

Siemens AG, Case Study December 2008

OIL & GAS PRODUCTION AUDITING

Gas Measurement and Analysis

LESSONS LEARNED FROM THE API 14.1 GAS SAMPLING RESEARCH PROJECT. Darin L. George and Eric Kelner

Balancing chemical reaction equations (stoichiometry)

Natural Gas. Shale Gas Impacts. Natural Gas Liquids (NGLs) Dan Brockett Penn State Extension

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Micro Motion 3098 Gas Specific Gravity Meter

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

F321 MOLES. Example If 1 atom has a mass of x g 1 mole of atoms will have a mass of x g x 6.02 x = 7.

Temperature. Number of moles. Constant Terms. Pressure. Answers Additional Questions 12.1

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

MINERAL OIL (MEDIUM VISCOSITY)

Thermo Scientific ConFlo IV Universal Interface

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

EnAlgae SOP: Biogas analysis

Thermal Mass Flow Meters

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

With proper calibration, the upper limit may be extended as needed.

TECHNICAL BRIEF Critical Point Drying

CHEMISTRY GAS LAW S WORKSHEET

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

Trace Gas Exchange Measurements with Standard Infrared Analyzers

MERCURY REMOVAL FROM NATURAL GAS & LIQUID STREAMS. John Markovs UOP Des Plaines, Illinois. Jack Corvini UOP Houston, Texas

Transcription:

BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction The most widely used method to determine BTU content of natural gas is by gas chromatograph. The analytical data provided by this means represents over half of the weighted information needed for total energy determination. The potential financial impact of this data is tremendous. It is imperative that the quality of the data produced by laboratories using gas chromatographs for BTU determination is accurate. Sample Procurement The first step in the process is to obtain a sample that is representative of the flowing stream. The sample procurement phase offers much opportunity to invalidate the process of producing accurate analytical data. It is unlikely that an analysis of a compromised sample will provide meaningful data. The personnel responsible for sampling must understand hydrocarbon phase behavior and how to obtain a representative sample. There are eight methods listed in GPA Standard 2166 Obtaining Natural Gas Samples for Analysis by Gas Chromatograph. These techniques are for obtaining spot samples. Personnel must follow the method chosen precisely. The more desirable means of obtaining natural gas samples is to use a continuous sampler, taking sample bites proportional to flow rate. Regardless of the sampling technique chosen, the following requirements apply. The sample point must have a sample probe installed or the quality of the sample procured will be of questionable validity. The sampled stream must be of a single-phase fluid and should be flowing at its normal rate. During the sampling process it is important to remove all atmospheric air and to not alter the component composition of the sample. Sample Handling It is important that the sample arrive at the laboratory promptly after procurement. Sample tracking programs should provide a means of identifying samples for comparison purpose and helps ensure timely processing of analytical testing. Natural gas samples are heated prior to analysis to return any condensable components to a vapor state. It is common practice to heat all samples to the same temperature for a specified period of time. If the equilibration temperature is not at least 20 degrees F above sample point temperature, it is necessary to heat these samples separately or the resulting BTU calculation will be in error. The equilibration time is at least two hours, and could be as great as twenty-four hours. Before sample analysis, confirm sample pressure to prevent analysis of a depressurized sample. Representative samples that are mishandled prior to analysis will provide inaccurate analytical results. Analytical Methods The most common gas chromatographic method used in the United States for determination of BTU content of natural gas is GPA Standard 2261 Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography. A Thermal Conductivity Detector, or TCD, measures compounds as they exit the analytical column, or columns. This detector is ideal for many analyses because it is sensitive to any compound whose thermal conductivity differs from the carrier gas. TCD s have a linear dynamic range of 10,000:1, which gives them a usable range of 0.01 to 100 mole percent. Three column types are used in this method to separate components of interest. See Table 1 for a list of columns. The first is the partition column. This column is usually about thirty feet long and one-eighth inch in diameter, packed with DC 200/500 silicone oil at thirty weight percent on Chromosorb P, 80-100 mesh, acidwashed. This column has been found to adequately separate methane through pentanes carbon dioxide and air. Nitrogen, however is not resolved from oxygen on this column, and what is commonly called nitrogen on this column is actually nitrogen and oxygen. Sample injection volumes are usually from 250 to 500 microliters. The pre-column is an eighteen inch section of this same column and precuts and backflushes the

hexane and heavier fraction to the detector ahead of the rest of the components. This reduces the analysis time from the former method of reversing the flow through the entire long column to backflush hexanes plus, and provides more accurate quantitation of this fraction. The column temperature is usually about 120 degrees C, isothermal, and the carrier flow rate set at about 30 ml per minute of helium. A 40 inch column packed with 1 percent DC 200/500 on Chromosorb P is used as a surge column to reduce valve switching upsets to the detector. If carbon dioxide content in the unknown samples is not close to the amount in the calibration standard, it may be necessary to use a porous polymer column to separate methane, carbon dioxide and ethane. This column is usually one-eighth inch in diameter by about ten feet in length. The column temperature is 100 degrees C, with helium flow set to about 30 ml per minute. Mesh size is normally 100-120 for columns less than 10 feet in length and 80-100 for longer lengths. Normally, the sample volume is 500 microliters. Propane and heavier components are commonly backflushed to vent and thereby ignored. A molecular sieve column will separate nitrogen from oxygen. This column is the same dimensions as the porous polymer column. Mesh size is usually 40-60, and the packing 13X Molecular Sieve. The column temperature is about 40 degrees C, and the helium flow rate is 25 ml per minute. This column will also quantify carbon monoxide. Compounds eluting after Carbon monoxide are backflushed to vent and not quantified. It is important to keep water vapor and carbon dioxide contact with this column to a minimum. If the column begins to lose of oxygen and nitrogen, cure the column at 250 degrees C for about four hours and it will regenerate. A 20 foot long by one-eighth inch 5A molecular sieve column, using argon carrier at 15 ml per minute, will separate helium and hydrogen. Mesh size is 40-60 and column temperature 40 degrees C. Another method is GPA Standard 2286, Tentative Method of Extended Analysis for Natural Gas and Similar Gaseous Mixtures by Temperature Programmed Gas Chromatography. The non-hydrocarbons, and hydrocarbons lighter than hexanes are determined by GPA Standard 2261, but hexanes and heavier are determined on a separate chromatographic run. The detector for this analysis is the Flame Ionization Detector, or FID. This detector has greater sensitivity than the TCD, but does not respond to non-hydrocarbon compounds. The linear dynamic range of an FID is 10,000,000:1. The preferred column in this method is sixty meters long, 0.32 millimeter diameter, with a one micron film thickness of methyl silicone. This is a partition column similar to the DC 200/500 packed column in GPA 2261, but is a fused-silica open tubular type or capillary column. The column temperature starts at forty degrees C, or less, and is temperature programmed up to over two-hundred degrees C. This temperature program allows the lower boiling point compounds to separate, and the high boilers to elute more quickly than by isothermal means. The late eluting compounds peak shapes are also improved. The hexanes plus fraction is separated into individual compounds in GPA 2286. This additional component allows the physical characteristics of hexanes plus to be calculated rather than assumed. By using GPA 2286 to determine hexanes plus physical characteristics for the GPA 2261 analysis, a more accurate determination of BTU is accomplished. Purpose CO 2, N 2, and C 1 -C 5 s Pre-cut of C 6+ Surge delay O 2 -N 2 CO 2 -Ethane He 2 -H 2 C 6+ speciation (extended) Column 1/8 x 30 30% DC 200/500 on 1/8 x 18 30% DC 200/500 on 1/8 x 40 1% DC 200/500 on 1/8 x 10 13X Molecular Sieve, 40-60 mesh 1/8 x 10 (Hayesep or Porapak), 100-120 mesh 1/8 x 20 5A Molecular Sieve, 40-60 mesh 0.32 mm x 60 m, (0.5-5 micron film) methyl silicon capillary Table 1 Gas chromatographs not using the aforementioned methods for BTU determination include on-line gas chromatographs, portable gas chromatographs and benchtop laboratory gas chromatographs. On-line GC s offer the advantage of performing many analyses during an accounting period and supplying data to electronic flow meters frequently. Portable GC s can eliminate the potential errors of sampling and handling samples. It is not uncommon to find benchtop GC s not configured according to GPA 2261. These GC applications should be verified by instruments that are configured according to the aforementioned methods.

Quality Assurance Accuracy is the sum of the bias error and precision error. The most common cause of bias error is invalid calibration blends. Typical causes of precision errors are improper instrument configuration and inconsistent operator technique. GPA 2261, Section 8 Precision, states the component precision data determined in 1982. Table 2 is taken from GPA 2261. Component Mol % Range Repeatability % Relative Reproducibility % Relative Nitrogen 1.0-7.7 2 7 CO2 0.14-7.9 3 12 Methane 71.6-86.4 0.2 0.7 Ethane 4.9-9.7 1 2 Propane 2.3-4.3 1 2 Iso-butane 0.26-1.0 2 4 n-butane 0.6-1.9 2 4 Iso-Pentane 0.12-0.42 3 6 n-pentane 0.14-0.42 3 6 Hexanes Plus 0.10-0.35 10 30 Table 2 It is good laboratory practice to order a new standard before replacement is required. The old blend and the new blend can be compared while the old blend is still valid. It is prudent to have multiple calibration blends available. Comparing blends of different composition demonstrates detector linearity. response factor or peak area is the starting baseline on the graph. After enough data points have been acquired, about seventeen, the baseline can be changed to the mean value. Using the relative percentages in the previous chart, one multiplied times the percent relative plus and minus the baseline value is the warning limit line for the chart. Two times the percent relative plus and minus the baseline value is the control limit line for the chart. Three times the percent relative plus and minus the baseline value is the scale of the chart. Three consecutive data points outside the same warning limit line or any point outside the control limit line indicate the need for further examination. Do not use the blend or instrument until the problem has been identified and corrected. Refer to Figure 2. GPA 2261, Section 4, outlines the procedure for a detector linearity check. Partial pressures, from 100 to 700 millimeters of mercury at 100 millimeter intervals, of methane are plotted against peak area on a linear scale graph. If the plot is linear, no adjustments are necessary. If the graph is not linear, the sample loop size needs to be adjusted. To properly size the sample loop, take the highest reading that is linear and divide it by barometric pressure in millimeters of mercury. Measure the sample loop and multiply the length by the previous calculated fraction and adjust the loop to this length. For example, 33770 33443 Ethane Mol. Wt. - Resp. Fact. Area 33116 32789 32462 32135 31808 Log RF 1/6/97 1/20/97 2/3/97 2/17/97 Figure 2 3/3/97 Date 3/17/97 3/31/97 4/14/97 Log MW The best means of monitoring calibration blends is to plot response factors on a control chart. The initial the highest linear reading is 650 mm Hg, the barometric pressure is 745 mm Hg, and the sample loop is eight inches long. Then, 650 divided by 745 is 0.8725, and 0.8725 multiplied times eight is approximately seven inches. See Figure 3.

1200000 1000000 800000 600000 400000 200000 0 Quality Control Linearity of Detector Response 0 100 200 300 400 500 600 700 Figure 3 After the sample is analyzed, the data must be checked to determine its validity and the quality of the analysis which was performed. The unnormalized total of the molecular percentages of compounds analyzed should be within plus or minus one percent of one-hundred percent. If not, then either instrument conditions have changed since calibration, a compound or compounds present in the sample was not detected, or detector linearity is not adequate to compare the range of compounds with the existing calibration blend. Check instrument conditions to determine if they have changed. Check the range of concentrations for components in the unknown sample to determine if they are close to the composition of the calibration blend. If neither of the above are the case, there may be components present in the unknown that were not detected, normally the same component as the carrier gas. The sample validation portion of a Laboratory Information Management System, or LIMS, should provide a means of comparing the current sample to previous analyses of that sample. If the composition varies noticeably, the cause should be determined. It is good analytical practice to compare individual component values statistically. The LIMS calculates the mean and standard deviation of previous analyses. Outlier values, or bad data determined staistically, are not included in future evaluations. Upper and lower component limits are calculated using the mean plus or minus the tolerance. If the new value is not between specified limits, it is flagged for scrutinization. Integration The signal from the thermal conductivity detector is a voltage output. The higher the concentration of analyte in the detector cell, the greater the voltage signal output. When only carrier gas is present in the detector, the signal is fairly constant and the output is at baseline. As compounds elute from the column and enter the cell, the signal changes. The signal is plotted over time and a device called an integrator interprets this data. Each component has a different thermal conductivity and therefore a different detector response. It is important that only one compound enters the detector cell at a time. This is called baseline. Integration settings do not overcome poor chromatography. The signal plotted over time produces a triangular peak shape. The area under the peak is compared to the concentration. This is the response factor. There are two types of response factors, relative and absolute. Relative response factors compare detector response of all compounds to that of the reference compound. In natural gas samples, methane is used as a reference peak and in natural gas liquid samples propane is used. Absolute response factors are divided into area / concentration and concentration / area. The calculated concentration does not change with response factor method change. See Table 3. 1 2 4 6 (2/5) 8 10 11 (*) (6x9) Name Mol % Ref. ARF Unk. Mol. Norm. Area Area % Mol % N 2 3.54 6224 0.0005688 13378 7.609 7.710 CO 2 2.24 4397 0.0005094 286 0.146 0.148 C 1 72.40 92053 0.0007865 91499 71.964 72.921 C 2 7.96 16432 0.0004844 17004 8.237 8.347 C 3 5.54 14292 0.0003876 16851 6.532 6.619 IC 4 2.63 7854 0.0003349 2029 0.679 0.688 NC 4 3.69 11335 0.0003255 7291 2.374 2.406 IC 5 1.00 3409 0.0002933 1603 0.470 0.476 NC 5 1.00 3487 0.0002868 2358 0.676 0.685 C6 + 0.00 2627 3866 0.000 0.000 Total 100.00 98.687 100.000 Table 3

2.384 31.791 0.750 2.0068 0.0478 3262.3 77.8 0.0478 0.0011 Calculations The concentration calculation most commonly used in BTU determination is molecular percentage. Molecular percentage is vapor volume percentage. BTU per cubic foot calculation is the sum of the products of each component s BTU heating value per cubic foot and the molecular fraction of each component. The result is the BTU per ideal cubic foot. Natural gas is a real gas and therefore the heating value must be corrected. The compressibility factor corrects the volume of a cubic foot as an ideal gas to that of a real gas. The BTU per ideal cubic foot value is divided by the compessibility factor to obtain the BTU per real cubic foot. Calculations are performed according to GPA Standard 2172, Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis. Physical constants are taken from GPA Standard 2145, Table of Physical Constants of Paraffun Hydrocarbons and Other Components of Natural Gas. Physical constants for the compounds determined by extended analysis can be found in GPA TP-17. See Table 4. The BTU per cubic foot multiplied by the volume yields the total energy of the stream. The unit of energy measurement is the dekatherm, or MMBTU. The heating value and volume calculations must be at the same base conditions. To change pressure base of the calculated heating value, divide the existing heating value by the existing pressure base and multiply by the desired pressure base. To change pressure base of the calculated volume, divide the existing volume by the desired pressure base and multiply by the existing pressure base. 0.472 27.380 0.172 2.4912 0.0118 4000.9 18.9 0.0581 0.0003 0.679 27.673 0.245 2.4912 0.0169 4008.9 27.2 0.0631 0.0004 0.879 23.274 0.378 3.1765 0.0279 5065.8 44.5 0.0873 0.0008 100.000 5.779 0.7804 1232.1 0.0159 Z 0.9963 Real Sp.Gr. 0.7830 Real Dry Btu 1236.7 Table 4 Two other energy measurement parameters that are sometimes confused are Gross versus Net and Dry versus Saturated. Gross heating values assume the water produced by the complete, ideal combustion of the gas and oxygen is condensed to liquid. Net heating values consider the water as a vapor. Gross heating values are used for custody transfer calculations and Net heating values for actual energy considerations. Dry heating value calculations ignore water vapor as a component of natural gas. Saturated, or Wet, heating value calculations assume the water vapor at base conditions to be at saturation. The contract conditions should be verified to determine heating value for custody transfer. 11 (*) 12 13 14 15 16 17 18 19 Norm. Cu. (11x10/ 12) Ideal Ideal (11x16 /100) Comp. (11x18 /100) Mol % ft./gal. GPM Sp. Sp. Btu/ Summ. Summ. Grav. Cu.Ft. Liquid Grav. Fact. Fact. 7.642 0.9672 0.0739 0.0044 0.0003 0.147 1.5196 0.0022 0.0197 0.0000 72.281 0.5539 0.4004 1010 730.0 0.0116 0.0084 8.273 37.476 2.208 1.0382 0.0859 1769.6 146.4 0.0239 0.0020 6.561 36.375 1.804 1.5226 0.0999 2516.1 165.1 0.0344 0.0023 0.682 30.639 0.223 2.0068 0.0137 3251.9 22.2 0.0458 0.0003