Note #6 02/04/2014 MiCOM S1 Studio V5.0.0 Release note #6 Release V5.0.0 This release provides a full installation of Schneider-Electric MiCOM S1 Studio V5.0.0. - It supersets version V4.0.1. - Please at installation, remove any previous version of MiCOM S1 Studio (do not remove the data models). Your database and systems will not be removed. - Install afterwards MiCOM S1 Studio V5.0.0. How to install This installation - is to be downloaded to your hard disk for later installation by running the.exe file - is providing an installation shield for a most convenient upgrade of your MiCOM S1 Studio - retains all existing systems (or projects) - can be run multiple times 03/04/2014 Page : 1/9
1. New features Schneider-Electric MiCOM S1 Studio V5.0.0 provides the following enhancements and features to MiCOM S1 Studio V4.0.1: 1. Downloading Single/part of setting to relay Capability to send to the relay by a serial communication (local or remote, front and rear communication ports) a single setting or a group of setting (the one(s) that has been changed) to the relay (P10, P20 and P40. This feature will made MiCOM S1 Studio homogenous with P30 option/features. 2. XML export Additional export format that could be easily editer and modified with current web tools. This XML export will export all setting/information/data from any platform relays. It could be used to customers as archive documents. 3. IEC 61850 configurator IEC 61850 Configurator will now manage Ed1 and Ed2. Same customer's HMI. Automatic Ed1 & Ed2 file management and importation (proper edition will be opened automatically) Fully in ligne with Px4x new hardware platform (P30 will follow in next release) 03/04/2014 Page : 2/9
4. Scan function Discovery feature: a list of device will be provided over any communication support. The list will provide IED information such as: address. The list refreshed in life time if a new IED is found or disconnected. From the listed device, the user could peform setting/record/event upload or place the device in a existing system. 5. Cyber Security Related on to P40 CS embedded function (P30 is schedule in next release to match with P30 CS relay project). Default password is set to "AAAA". Impacted module by Cyber Security : MiCOM S1 Studio IED configurator PSL editor BTC UPTC P746 remote HMI Tool. Module not "under" Cyber Security : Courier measurement viewer Goose Editor 6. Dual Communication Px4x platform only. New option related to new hardware option for Px4x relays. 03/04/2014 Page : 3/9
7. SFTP communication protocol Px4x platform alignement. New protocol available for P30 relay ranges. 8. Implementation of function that are available in the S&R 103 communication module at MiCOM S1 Studio level. List of functions: Menu Function View / PSL Editor View / Protection View / Control Tool / Design Version Tools / Copy Parameter Subset Description Graphical editor for ALL m-to-n parameters and list parameters, you can freely switch between graphical editor and the usual text editor without saving or any other user action. Select View of Settings: Protection parameters shall be displayed or shall hidden Select View of Settings: Control parameters shall be displayed or shall hidden Define, Extract and Print the hardware configuration of a device Copy the all parameters of one parameter subset to another one Context menu: Menu Function Properties Description Display of property details of the selected parameter 03/04/2014 Page : 4/9
9. User define Signal Naming (Px3x relays) Up to date USB driver (computer) has been implemented. MiCOM S1 Studio will install the corresponding USB driver related to the PC environment. 10. Px1x USB driver Px43 platform alignement. New protocol available for P3àrelay ranges. 11. Polish language Support Installation of Micom S1 Studio in polish language is now available (menus). 12. MiCOM S1 Studio vulnerability issue. Issued from the American Agency (NERC) report, the V5.0.0 release is solving any of vulnerability issues. After S1 installation file/folder could be remove/deleted or exchange: Folders and files that must be marked Read only. Window service DLL must be marked to Read as solution to solve privileges issues. Note: digital signature was implemented in V4.0.1 release. 03/04/2014 Page : 5/9
2. Fixed issues Issues Severity Ref. Description Qual. Ref. Major 1928 COMM1: force signals 2375 MCL file shows blank page while opened with IED configurator(chinese version OS) 3199 Add new device Exception when the data model for the selected device is bad. 3323 Accepting password level 1 and 2 for extracting Curve 3423 Import MCL file to wrong setting file will crash S&R 103 3761 Studio will sometimes crash when working long time with Px30 devices 3801 MiCOM S1 Studio: connection password Dev Track 7690 3822 Message error when opening P92x V12 data model in S1 Studio 3823 MiCOM S1 Studio is crashing when ethernet port is used Devtrack Hotline ID NÂ 7881 3894 Micom Studio 3.5.2 does not indicate correctly that download of the settings to the P12x relay was refused because of IED in local mode. PCL10112 3963 S1 Studio: file naming disturbance records Px40 and Px30 Dev Track 8540 3964 impressions PSL MiCOM S1 Studio Dev Track 8526 3975 S1 Studio: Px30 wrong text when sending setting file Dev Track 8581 3976 Micom S1 studio Value alignment to step size Dev Track 7531 4033 Studio Px30 Settings Comparison Fails Dev Track 8676 4040 Communication issue with Px20 Relay JFAI 0014 4041 P243 Relay crash Dev Track 8817 4042 DNP3 Integer Scaling step size For P544 relay Firmware P544 4 540_G Dev Track 8397 4043 MS1S exception in Quick connection file transfer mode and Modbus problem 4089 Match factor and EF problem Dev Track 8392 Dev Track 8192 4142 P521 Can't open Phase II default file in Studio Dev Track 9277 4192 Cannot change device address using Studio via Rear port 03/04/2014 Page : 6/9
Issues Severity Ref. Description Qual. Ref. Normal 1385 IEC 103: Telegram Recording in File 1665 COM4 not visible in connections >> setup parameter dialog 1849 Import SCL â Px30 model numbers inconsistent. 2114 â Add Exisng Fileâ does not check model number (Courier). 2767 Modbus settings file conversion invalid report 3004 Modbus settings file isn't refreshed correctly 3277 P126 7 datamodels: if the values measured by the device are incorrect, they doesn't must be displayed PCL1146 3401 Abort sending setting process failed on modbus device 3672 Studio give wrong message when extract Px20 records was interrupted 3675 S1 Studio MCL file conversion generates false error message DevTrack : 5965 3820 PSL Editor Error communication issue Dev Track 6836 3954 Ethernet communication not working after disconnect 3989 No detail information about the failure when sending MCL file to Px30 device 3994 P740 Topology Tool incompatible with S1 From v3.5.1 PCL10088 4000 Studio Px30 Settings Comparison Fails Dev Track 8676 4063 DNP3 integer scaling MJAN 0030 4086 USB Driver for P10 Platform Px10 devices connected via USB change device address 4224 EView data model directory Issues Severity Minor Ref. Description Qual. Ref. 2739 Text in French language in.txt files created after 'Convert Settings File...',Modbus 4159 Wrong translations in German version of the tool. PCL10134 03/04/2014 Page : 7/9
Issues Severity Enhance ments Ref. Description Qual. Ref. When extracting the settings using S1 Studio, if there are any trip 3780 signals on, all the trip signals reset and few ms after the trip signals turn on again PCL10092, DevTrack 6855 4013 S1 Studio 4.0.1 Issue with Px30 extended platform Dev Track 8824 03/04/2014 Page : 8/9
Other notes Windows compatibility: V5.0.0 is qualified with and verified on Windows 7 32 bits. V5.0.0 is not designed or verified on Windows Vista. Eview and GOOSE editor are not Windows 7 qualified MiCOM S1 Studio is compliant to Windows 7 (64 bits). (qualification planed in next 2014 release). Px4x Text editor is not functioning on W7 64 bits. Assistance Please go to our web site www.schneider-electric.com and click on Customer Care Center. 03/04/2014 Page : 9/9