LABORATORY REPORT Prepared for PROJECT: 2614 Morganton Road Fayetteville, NC CEI LAB CODE: A14-10364 DATE ANALYZED: 07/30/14 DATE REPORTED: 07/30/14 TOTAL SAMPLES ANALYZED: 20 # SAMPLES >1 : 5 TEL: 866-481-1412 www.ceilabs.com
Asbestos Report Summary PROJECT: 2614 Morganton Road Fayetteville, NC CEI LAB CODE: A14-10364 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 Client ID Layer ID Color Sample Description 01-01 A1783943A Floor Tile Chrysotile A1783943B Mastic Chrysotile 01-02 A1783944A Floor Tile Chrysotile A1783944B Mastic Chrysotile 02-01 A1783945A Floor Tile Chrysotile 8 A1783945B Mastic 02-02 A1783946A Floor Tile Chrysotile 8 03-01 03-02 04-01 05-01 05-02 06-01 06-02 07-01 08-01 08-02 09-01 09-02 10-01 A1783946B Mastic A1783947 Brown,White Ceiling Tile A1783948 White, Ceiling Tile A1783949 Brown Adhesive A1783950 Brown Ceiling Tile A1783951 Brown Ceiling Tile A1783952,Gray Wallboard/Joint Compound A1783953,Gray Wallboard A1783954, A1783955,White Shingle A1783956,White Shingle A1783957 Roof Felt A1783958 Roof Felt A1783959 Roof 11-01 A1783960,Gray Roof Coating Chrysotile 12-01 12-02 A1783961 Gray Window Glazing A1783962 Gray Window Glazing Page 1 of 1
BULK ANALYSIS Client: 112 Sarabande Drive Cary, NC 27513 CEI Code: A14-10364 Date Received: 07-29-14 Date Analyzed: 07-30-14 Date Reported: 07-30-14 Project: 2614 Morganton Road Fayetteville, NC BULK PLM, EPA 600 METHOD Client ID ID Description Attributes NON- COMPONENTS Non- 01-01 A1783943A Floor Tile 70 1 Vinyl Chrysotile A1783943B Mastic 2 Mastic Chrysotile Notes: Possible contamination from the floor tile. 01-02 A1783944A Floor Tile 70 1 Vinyl Chrysotile A1783944B Mastic 2 Mastic Chrysotile Notes: Possible contamination from the floor tile. 02-01 A1783945A Floor Tile 67 1 Vinyl 8 Chrysotile A1783945B Mastic 2 Mastic 02-02 A1783946A Floor Tile 67 1 Vinyl 8 Chrysotile Page 1 of 5
BULK ANALYSIS Client: 112 Sarabande Drive Cary, NC 27513 CEI Code: A14-10364 Date Received: 07-29-14 Date Analyzed: 07-30-14 Date Reported: 07-30-14 Project: 2614 Morganton Road Fayetteville, NC BULK PLM, EPA 600 METHOD Client ID ID Description Attributes NON- COMPONENTS Non- A1783946B Mastic 2 Mastic 03-01 A1783947 Ceiling Tile Brown,White 9 2 03-02 A1783948 Ceiling Tile White, 9 2 04-01 A1783949 Adhesive Brown 9 Mastic 05-01 A1783950 Ceiling Tile Brown 9 2 05-02 A1783951 Ceiling Tile Brown 9 2 06-01 A1783952 Wallboard/Joint Compound,Gray 12 Gypsum Page 2 of 5
BULK ANALYSIS Client: 112 Sarabande Drive Cary, NC 27513 CEI Code: A14-10364 Date Received: 07-29-14 Date Analyzed: 07-30-14 Date Reported: 07-30-14 Project: 2614 Morganton Road Fayetteville, NC BULK PLM, EPA 600 METHOD Client ID ID Description Attributes NON- COMPONENTS Non- 06-02 A1783953 Wallboard,Gray Notes: No Joint Compound Present. 12 Gypsum 07-01 A1783954, 2 Silicates 08-01 A1783955 Shingle,White 4 3 Gravel 08-02 A1783956 Shingle,White 4 3 Gravel 09-01 A1783957 Roof Felt 2 09-02 A1783958 Roof Felt 2 10-01 A1783959 Roof 8 Page 3 of 5
BULK ANALYSIS Client: 112 Sarabande Drive Cary, NC 27513 CEI Code: A14-10364 Date Received: 07-29-14 Date Analyzed: 07-30-14 Date Reported: 07-30-14 Project: 2614 Morganton Road Fayetteville, NC BULK PLM, EPA 600 METHOD Client ID ID Description Attributes NON- COMPONENTS Non- 11-01 A1783960 Roof Coating,Gray 6 32 Chrysotile 12-01 A1783961 Window Glazing Gray 22 12-02 A1783962 Window Glazing Gray 2 Page 4 of 5
LEGEND: Non-Anth = Non-Asbestiform Anthophylite Non-Trem = Non-Asbestiform Tremolite = Calcium Carbonate METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 The detection limit for the method is by visual estimation and 0.2 by 400 point counts or 0.1 by 1,000 point counts. Due to the limitations of the EPA 600 Method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarizing light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. CEI s, Inc. can perform positive stop analysis if requested by customer. However, it is the responsibility of the customer to determine if the samples grouped together are in fact the same type of material and belong to the same homogeneous area. This report may not be reproduced, except in full, without written approval by CEI LABS. CEI LABS makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U. S. Government. ANALYST: Ritika Seal APPROVED BY: Tianbao Bai, Ph.D. oratory Director CEI s, 107 New Edition Court, Cary, NC 27511, Phone: (866) 481-1412 Page 5 of 5