Power management software. PowerLogic ION Enterprise

Similar documents
StruxureWare Power Monitoring Expert 7.2 Functions and characteristics

scalable data centre energy management solution

Meter data management software

WinPM.Net. Web-enabled Software. Power Monitoring. Answers for industry.

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Access valuable energy and power information from your system

PowerLogic ION Enterprise 5.6

Electrical Network Management System

VM600 CMS Software. VM600 Series Software for Condition Monitoring System (CMS) FEATURES DESCRIPTION

PowerLogic ION Enterprise 6.0

Communicate and view data from meters with one simple device

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

IBM SmartCloud Monitoring - Application Insight. User Interface Help SC

IBM Tivoli Monitoring Version 6.3 Fix Pack 2. Windows OS Agent Reference

Manage critical infrastructure, energy, revenue, reliability and power quality.

StruxureWare Power Monitoring 7.0.1

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

Power Monitoring Expert software. Benoit Barbalat Energy Management Solutions Schneider Electric Canada

IT Infrastructure Preparation for StruxureWare Power Monitoring Expert 8.0 Installation

StruxureWare Power Monitoring 7.0.1

PowerLogic Tenant Metering Billing and Meter Reading Software Solutions

Electrical Monitoring and Control System Solution. Guideform Specification

SCADA Questions and Answers

How To Use Safety System Software (S3)

Meter Data Management Software. PrimeRead Energy SuiteSM

EnerVista Viewpoint Monitoring

Modular Enterprise-wide Energy Management Monitoring System

You were seeking a protocol translator. Eaton delivered a vital data flow processor.

Windows PCs & Servers are often the life-blood of your IT investment. Monitoring them is key, especially in today s 24 hour world!

Energy Management System (EMS)

StruxureWare TM Center Expert. Data

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

EnerVista TM Viewpoint Monitoring v7.10

How To Set Up An Ops Console On A Pc Or Mac Or Macbook

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009

Netwrix Auditor for SQL Server

PowerLogic energy & power management systems

Advansoft ODM PLANT MOBILE DATA MANAGEMENT & DECISION SUPPORT SYSTEM

PowerLogic ION7550/ION7650 Power and energy meters User guide

EnerVista Viewpoint Monitoring

Monitoring & Control of Small-scale Renewable Energy Sources

Netwrix Auditor for Windows Server

Network device management solution.

Netwrix Auditor for Active Directory

Complete fleet management package for Qualitrol Information Products

Rocket Servergraph Professional Proactive Data Protection Management

PowerLogic ION Enterprise 6.0

Event Notification Module TM

Online Help StruxureWare Data Center Expert

SCADA Systems Automate Electrical Distribution

Network device management solution

Semaphore T BOX Applications in Data Center Facilities

StruxureWare Power Monitoring Expert 7.2

Power & Environmental Monitoring

StruxureWare Power Monitoring Expert - Data Center Edition

PlantStruxure. PPT_VH040809_EN Fully Integrated Process Automation

Smart Energy & Power Quality Solutions. GridVis -Energy Software. Web visualisation for your energy management

AutoLog ControlMan. Remote Monitoring & Controlling Service

Tivoli Storage Manager for Windows

IBM InfoSphere MDM Web Reports User's Guide

Tivoli Security Compliance Manager

StruxureWare Power Monitoring Expert 7.2

Internet-Accessible Power Monitoring & Control Systems

Tracer Summit Energy Services

ERserver. iseries. Backup, Recovery and Media Services (BRMS)

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Smart Business Architecture for Midsize Networks Network Management Deployment Guide

Copyright 2014 GE Multilin Inc. All rights reserved. EnerVista Viewpoint Monitoring Quickstart Guide for version 7.1x. EnerVista, Viewpoint

Achieving Compliance with the PCI Data Security Standard

Product Overview. Dream Report. OCEAN DATA SYSTEMS The Art of Industrial Intelligence. User Friendly & Programming Free Reporting.

StruxureWare TM Data Center Expert

Classification of Data Center Operations Technology (OT) Management Tools

IBM Campaign Version 9 Release 1.1 February 18, User's Guide

EMS. Trap Collection Active Alarm Alarms sent by & SMS. Location, status and serial numbers of all assets can be managed and exported

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

The software solution to complete your flow monitoring program

Intelligent Network Management System. Comprehensive Network Visibility and Management for Wireless and Fixed Networks

Features Overview Guide About new features in WhatsUp Gold v12

Status Enterprise Technical Overview

Netwrix Auditor for Exchange

Operations Console Setup

Tivoli Endpoint Manager for Patch Management - Windows - User's Guide

Monitoring: Linux OS Agent Version Fix Pack 2 (Revised May 2010) User s Guide SC

Software Installation

The First Suite of OPC-Based Automation Software Components

CONTEG Pro Server Management software

Radiological Assessment Display and Control System

Classification of Data Center Infrastructure Management (DCIM) Tools

IBM Rapid Restore Ultra Version 4.0. User s Guide

IBM Tealeaf cxconnect for Web Analytics Version 9 Release 0.1 December 4, cxconnect for Web Analytics Administration Manual

AKCess Pro Server Management Software

imvision System Manager

ERserver. iseries. Digital certificate management

Transcription:

PowerLogic ION Enterprise Power management software A complete solution for cutting energy-related costs and aoiding power-quality equipment failures and downtime.

Manage real-time power conditions and energy efficiency PowerLogic ION Enterprise software is a complete power management solution for energy proiders and industrial or commercial operations. It gies engineering and management personnel the information they need to cut energy-related costs, aoid downtime and optimise equipment utilisation. The software uses a choice of industry-standard network technologies, including Ethernet and wireless, to automatically collect and store data from key electrical distribution points and physical assets. It forms a layer of energy intelligence across your facility, campus, serice area or your entire enterprise, acting as a unified interface to electricity and other consumable resources such as water, compressed air, gas and steam. Web-enabled access gies each user a personalised iew to timely, releant information. PowerLogic ION Enterprise helps you track real-time power conditions, analyse power quality and reliability, and respond quickly to alarms to aoid critical situations. It helps you study historical trends to reeal energy waste or unused capacity as well as erify efficiency improements and allocate costs to buildings, departments or processes. The software includes sophisticated load aggregation and arithmetic calculation. Coordinated control capabilities can be used to manage demand or power factor and to manage loads or generators. Customised information is easily seamlessly shared with all stakeholders and with other business and automation systems. Typical application Real-time display of data Alarms and control functions Power quality analyses Historical trend analyses Customised reporting Corporate network Incoming power feeds and on-site generation Switching and mitigation equipment Power distribution equipment Loads, processes or tenants

Typical applications Financial management including accounting and billing Facility and energy management Operations management including engineering, planning and maintenance For infrastructure, industrials and buildings Energy saings Measure efficiency, reeal opportunities and erify saings Sub-bill tenants for energy costs Allocate energy costs to departments or processes Reduce peak demand surcharges Reduce power factor penalties Strengthen rate negotiation with energy suppliers Enable participation in load curtailment programs (e.g. demand response) Identify billing discrepancies Leerage existing infrastructure capacity and aoid oer-building Support proactie maintenance to prolong asset life Energy aailability and reliability Validate that power quality complies with the energy contract Verify the reliable operation of equipment Improe response to power quality-related problems Optimise system relay coordination Power generation, transmission and distribution Serice entrances and onsite generation For electric utilities Energy aailability and reliability Improe T&D network reliability Enhance substation automation to reduce field serice time Maximise the use of existing infrastructure Power quality Verify compliance with new power quality standards Analyse and isolate the source of power quality problems Key features Integrated network comprising corporate intranet, Internet, serial, dial-up or wireless connections Power mitigation and main power distribution equipment PDUs and data serers Tenants, departments or subcontractors Processes, lines, machines or equipment Typical applications of PowerLogic ION Enterprise within a PowerLogic power and energy management system Scalable, flexible architecture: grow your system to hundreds of metering points; add distributed serers and clients; use ION modular programming for complex data processing and control functions Data acquisition: eliminate manual meter reading by collecting system-wide data from PowerLogic energy meters, MicroLogic breaker control units and third-party water, air, gas, electricity or steam ( WAGES ) meters, as well as from power distribution or mitigation equipment web serices; communicate oer Internet, Ethernet, wireless and other methods Interoperability: share data with third-party SCADA, automation and business systems; compliant with ODBC, OPC and PQDIF standards Web portal: multi-user access to customised graphical iews of system diagrams, real-time and historical data, status indicators and alarm messages; multi-leel security Reporting: preconfigured and custom reports; support for Microsoft Excel and other third-party reporting tools; scheduled distribution ia email or web Trending: graph any combination of measured parameters; aggregate loads Power quality analysis: wide-area eent monitoring and plotting (ITIC, SEMI); power quality compliance monitoring and reporting to international standards (IEC 61000-4-30, EN50160); waeform iewer; harmonics, K-factor, crest factor, and symmetrical components measurements Alarms and eents: trigger on complex conditions; generate alarm notifications; log all releant eent data Control: manual or setpoint-triggered control functions; coordinated control of multiple loads, generators, relays or other power distribution and mitigation equipment

Noember 10:46 Software architecture WWW Data presentation Functional components Data acquisition and management Data presentation Enterprise-wide, multi-user data and control access through local serer interface, thin-client web browser, or terminal serices; tiered security Information and alerts ia mobile phone, PDA and other deices Functional components (on main serer or workstations) Management Console configure your PowerLogic ION Enterprise network, including communication paths, deices and logical groups. Designer customise the modular functionality of ION deices and Virtual Processors (see below) Vista real-time displays of measurements and status indicators, power quality analysis, historical trending, alarms and manual control Reporter predefined or custom reports; support for third-party reporting tools Data acquisition and management Virtual Processor - multi-site aggregation, coordinated control, complex calculations and alarming, logging for non-recording deices (e.g. interal kwh) Site Serer - continuous or scheduled retrieal of data from up to hundreds of remote deices oer Internet, Ethernet, telephone, serial, wireless, or satellite connections SQL ODBC-compliant databases - Microsoft SQL Serer 2005 (with support of SQL Serer 2000). Log deice data, system data and eents with accurate meter synchronisation (±16 ms or ±1 ms using GPS) for precise eent timestamping, power quality analysis and reenue billing; data is securely accessible using industry-standard database tools; add distributed databases and serers as required for load balancing OPC DA Client (standard), OPC DA Serer (optional) and PQDIF Exporter (optional) supports data import/export with compliant deices and systems Connect to meters, sensors, controllers, web serices and other systems. Extract alues from spreadsheets to combine with dynamic power and energy calculations. Data acquisition and integration Integrate metering of electricity and other consumed serices such as gas, steam, air, and water. Standard product offers natie support for PowerLogic ION series, PM800 series, PM700 series, PM210 and legacy ACM series power and energy meters. Enables access to all real-time and logged data, control of on-board relays and digital outputs, remote configuration and firmware upgrading. Also supports data access from MicroLogic circuit breaker control units (types A, P and H). Easily customised to add support for third-party meters, transducers, PLCs, RTUs and power distribution or mitigation equipment. Quickly add and configure direct communications with remote deices oer Modbus RTU or Modbus TCP protocols using easy-to-use deice templates. Or connect the outputs of transducers or other deices to the digital and analog inputs of PowerLogic meters. Use MeterM@il encrypted email messaging to securely access meter data oer the Internet within firewall restrictions. Scalable platform enables remote deices and user clients to be added as needs grow while maintaining your original inestment. Integrate with other energy management or automation systems (e.g. SCADA, BAC, DCS, ERP) through ODBC, XML, OPC, email, FTP, CSV and PQDIF compliance; integrate with web serices through XML.

Real-time monitoring Desktop access to power system information from any department, building or region. Graphical iews of releant, actionable information customized for each user. View key distribution points across one or more facilities or substations, accessible from any workstation, locally or around the world. Display real-time power and energy measurements, historical trends and data logs, alarm conditions, equipment status (on/off, temperature, pressure, etc.), control triggers and analysis tools. Use the Virtual Processor to perform sophisticated data computations, then display and log deried alues. Select pre-configured diagrams or easily create customised iews comprising digital readouts, dials, bar or trend graphs, one-line or eleation diagrams, maps, photos and animation. Set up hyperlinks between diagrams, then use easy point-and-click naigation to reeal deeper layers of detail, e.g. start with a site oeriew, click once to reeal a feeder, click again to see a disturbance analysis. Group releant measurements, indicators and controls into a library of conenient iews. Easily extract and analyse selected ranges of information from the database using a query wizard. Reporting Allocate costs, consolidate billing or negotiate contract olume pricing. Assure compliance with PQ standards and erify the results of operational improements. Reports can be generated manually, on schedule or eent-drien. Distribute automatically as email or HTML. Standard reports: Generate reports through Microsoft Excel using a fast and conenient report wizard interface. Aggregate energy and demand reports combines multiple feeds, costs for each tariff period oer requested interals, matched to utility billing structures, with multi-year scheduling and time-of-use actiity profiles. Aggregate load profile reports system-wide usage patterns oer the specified date range, including timestamps and peak usage. IEC 61000-4-30 and EN50160 compliance reports pass/fail indicators help you quickly assess system power quality leels, including flicker. Power quality analysis reports disturbance waeforms, oltage tolerance cures, and harmonic histograms. Custom reports: Use Visual Basic for Applications or any off-the-shelf SQL Serer reporting tools, such as Crystal Reports, to customise reports and enable further analysis. Combine PowerLogic ION Enterprise data with other databases to reeal true business conditions. Our serices team can help you with custom report deelopment.

Trend analysis Support load studies or expansion planning, optimise equipment use by maximising capacity or balancing loads. Reeal critical trends, expensie processes or energy waste. Minimise equipment damage and downtime by pinpointing the source of disturbances, erifying the effect of system upgrades, and alidating compliance with power quality standards. Generate one or more trend graph oerlays for interpretation of data using simple isual analyses. Trend on any measured parameter: oltage, current, power, power factor, demand, predicted demand, energy, harmonics, temperature, etc. Graph aggregate load profiles from multiple metering points or compare related parameters from across your enterprise. Create usage profiles to reeal demand peaks, dangerous trends, or unused capacity. Track system-wide energy-related costs for each building, feeder, process or tool. Power quality analysis Continuous, wide-area monitoring, data capture and reporting for power quality and reliability conditions. IEC 61000-4-30 and EN50160 compliance reporting erifies power quality performance to international standards. Quickly reiew power quality indices as numeric charts or graphic profiles. Requires PowerLogic ION7650 meters or other deices that support compliance monitoring. Display harmonic histograms, odd/een harmonics, THD, K-factor, crest factor, phasor diagrams and symmetrical components. Plot waeforms of up to many seconds in duration, with oerlays that correlate phase-to-phase relationships between oltages, currents and cascading failures. Plot sags, swells, short duration transients and other disturbance eents on industry-standard oltage tolerance cures, including ITIC (CBEMA) and SEMI. For any eent, display a list of associated time-stamped incidents, then click on any incident to see more detailed information. Supports a wide range of applications: Diagnose and isolate the cause of power quality-related equipment or process problems. Proactiely assess current power quality conditions and trends. Identify equipment ulnerabilities and erify reliable operation of power distribution and mitigation equipment. Benchmark power quality performance and compare serice areas, facilities or processes. Set a performance baseline and erify the results of system changes or equipment upgrades. Patented ION technology PowerLogic ION Enterprise and a ariety of PowerLogic ION metering products feature the unique ION architecture. Modular, flexible architecture offers extensie customisation of functionality using a simple building block approach. Uniquely addresses adanced monitoring and control applications. Adapts to changing needs, aoiding obsolescence. Use drag-and-drop icons to quickly create customised ION metering, logging or control functionality within your software or hardware.

Alarms and eents Respond to a notification, then click an on-screen indicator to retriee the time, location, and nature of the eent. Click again to study waeforms, tolerance cures or a report. Receie alerts to outages or impending problems that could lead to equipment stress, failures or downtime. Configure alarms to trigger on power quality eents, power thresholds or equipment conditions. Meter-based alarms are immediately pushed to the software without waiting for system polls. Annunciate alarms through operator workstations, email, mobile phone or PDA using messages customised for the task. Configure the combinational logic of the Virtual Processor to trigger on complex or summary conditions and automatically send out notifications, upload all associated eent data and generate a report. Log complete information on an eent, including related coincident conditions and waeform captures, all with accurate timestamps. Correlate and categorise sequences of eents. Schedule maintenance based on operating history, eents and alarms. Manual and automated control Control loads, generation, and power quality mitigation equipment across your enterprise or serice area. Optimise switching with the latest status and base loading data. Perform fast, manual control operations by clicking on-screen trigger buttons; operate remote breakers, relays and other power distribution and mitigation equipment Use the Virtual Processor to perform automated control oer distributed equipment: Gathers data from multiple deices and incorporates process ariables Initiates automatic, coordinated control actions if predefined thresholds are exceeded Supports a wide range of applications: Shed loads or start up peak-shaing generators in response to interruptible rates, real-time pricing, or to aoid setting a new peak demand Manage distributed generation assets Control capacitor banks to correct power factor, improe energy efficiency and aoid penalties Start fans to preent transformer oerheating if total harmonic distortion is too high

Features Standard Optional Automated data acquisition from sites/deices SQL 2005 Express Edition database SQL 2005 Standard Edition database Web-enabled real-time monitoring Reporting Trend analysis Power quality analysis, compliance reporting Alarms and eents Manual and automated control OPC DA client OPC DA serer PQDIF data export PowerLogic power and energy meters: ION8800 ION8600 ION7650/7550 series PM800 series ION7300 series PM710, PM750 ION6200 PM210 Circuit breaker control units: MicroLogic, Type A, P and H System requirements Supported deices Power Measurement legacy power and energy meters: ION8500/8400/8300 ION7700 ION7600/7500 series ACM3720 ACM3710 ACM3300 Other: Modbus-compatible deices Other deices through OPC Please consult your local Schneider Electric representatie for complete system requirements and commissioning information for PowerLogic ION Enterprise. The following are minimum requirements to support 1 to 25 meters with factory default settings. Serer hardware: CPU requirements are dependent on number of deices and clients to be supported; minimum is 2 GHz CPU, 1 GB RAM, 40 GB disk drie, CDROM drie and Ethernet port. For applications with a single primary serer and single client, serer can run Windows XP Professional. For larger systems primary serer requires 32-bit Windows Serer 2003 certified (see Microsoft website). Use of secondary serers is also supported. Serer software: Microsoft Office 2003 Suite, Microsoft Windows IIS (Internet Information Serices) Client software requirements: 32-bit Windows XP Professional or Windows Serer 2003, Microsoft Office 2003 Suite Modem support: For dial-up connections, supports any modem compatible with the WinModem standard. Schneider Electric Industries SAS 89, bouleard Franklin Rooseelt F - 92500 Rueil-Malmaison (France) tél : +33 (0)1 41 29 85 00 The 2007 award recognizes Schneider Electric for its technological adancements and wide product range in the field of power quality (PQ) and energy management solutions. In total, this is the fourth award that Schneider Electric and [recently acquired] Power Measurement hae receied from Frost & Sullian in recognition of achieements in this arena. Prithi Raj, Frost & Sullian research analyst Power Measurement and its ION products were recently acquired by Schneider Electric and integrated within our PowerLogic range of software and hardware, creating the world s largest line of power and energy management solutions. Please contact your local sales representatie for ordering information. Visit www.powerlogic.com for more information on other PowerLogic products, applications and system solutions. As standards, specifications and designs deelop oer time, always ask for confirmation of the information gien in this publication. PowerLogic, ION, ION Enterprise, MeterM@il and Modbus are either trademarks or registered trademarks of Schneider Electric. Printed on recycled paper ART 821272 / 2008 - Schneider Electric - All rights resered www.powerlogic.com www.schneider-electric.com PLSED106018EN 01-2008 Publishing : Schneider Electric Production : Schneider Electric PMC Printing : Imprimerie du Pont de Claix - made in France