Heating with wood chips and pellets



Similar documents
PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet.

HIGH QUALITY COMPONENTS

HAPERO BALANCE / FLASH. 15 kw / 25 kw / 35 kw. Basement Floor Living room ENERGIETECHNIK GMBH PLUG INSTITUT FÜR BRANDSCHUTZTECHNIK


Hackney Biomass Boiler Information Request Form

Business Plan: Wood chip gasifier (Deliverable 5.2)

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

How To Build A Swebo Biotherm

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Half the cost Half the carbon

P4 Pellet. Pellet boiler. P4 Pellet.

The Current State of Austrian Pellet Boiler Technology

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

BIOHOUSING Seminar Success stories of biomass heating in small scale

INTEC Engineering GmbH Heating Solutions for the Marine Industry

COMBLOC The future of packaged multi-fuel fired steam boilers. Ultra Compact. High Performance

Daikin Altherma Hybrid Heat Pump

High-efficient gas boiler CompactGas

Daikin Altherma Hybrid Heat Pump

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Apartment and Communal Heating Solutions

HEAVY DUTY STORAGE GAS

Steam and hot water boiler systems for industrial and municipal power generation Dr.-Ing. Wolfgang Sobbe VKK Standardkessel Köthen GmbH

How To Use A Corona Mdi 110

The Best Selling Domestic Stainless Steel Oil Boiler

Service & Maintenance Packages. Service & After-Sales. A Strong Company

Austrian pellet boiler technologies state-of art, ecological evaluation and future developments

Frequently Asked Questions

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Daikin Altherma Hybrid Heat Pump

ROTEX gas hybrid heat pump. A strong team.

Micro cogeneration. Affordable, efficient and innovative

PBZ Heavy. PBZ Heavy. CNC Gantry-Type Machining Center. Power - Performance - Precision.

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Top Technology for Industry, Agriculture, Business and Communities

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

HEAT INTERFACE UNITS (Modular)

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Efficiency on a large scale CFB Steam Boilers

The natural ombination

accord 20 fx CNC machining centre

1 DESCRIPTION OF THE APPLIANCE

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

Södra Näs Vimmerby Energi AB Biomass District Heating Plant, Sweden

Natural geothermal energy.

The soot and scale problems

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Stora Enso Fors Ltd Sweden

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Biomass heating: a guide to small log and wood pellet systems

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS

Laddomat Charging unit

york air-conditioning products Residential & VRF News 2015

EcoDesign & Labelling Directive (ErP)

UDSA - UDSBD unit heater

A Weissenbach AUSTRIA Tel. +43/2672/890-0, Fax: Internet: office@polytechnik.at

Description of functions

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Session 2: Hot Water Supply

ETC -SV. Class 0 oil-free compressed air through catalysis

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Manual piston sampler...m 11

SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

Optimising Glass Melting Processes with Energy & Mass Balance Calculations

Continuous flow direct water heating for potable hot water

Electric Flow Boiler

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Cooking at the Speed of light!

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

DMU 75 / 95 monoblock

Layout Planning of Waste-to-Energy Plants

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants

ECOplus Solar Cylinder

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Backup Fuel Oil System Decommissioning & Restoration Plan

Biomass heating: a guide to medium scale wood chip and wood pellet systems

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Laddomat 21 Charging Unit

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

The natural ombination

Energy Efficiency HOSPITALITY.

Atlas Copco Surface drill rigs. SmartROC T35/ T40. Hole diameter: SmartROC T35: mm (2 1 /2 4 1 /2 ) SmartROC T40: mm (3 5 )

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

A new range of clean burning multifuel stoves

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

BOILER OPERATORS HANDBOOK

C18 ACERT Fire Pump Tier bkw/ rpm

Smile. The All-In-One Heating Controller

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Working width m

BIOMASS BOILER. Servicing and Maintenance Years. No Renewable Products Installed, Maintained

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

1300 MAXTRAK SPECIFICATION

Storage and Handling Requirements for Biomass. Richard Farnish, CEng MIMechE

Transcription:

YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150

Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system Economy of operation with: High level of efficiency BioControl 3000 with energy management Energy efficient drive technology High quality materials Environmental friendly with: Low emissions Local resourced fuel (wood chippings G30 (max size)- W35(max moisture in %), pellets Alternative fuel (on request) 20 years experience In house development and testing European wide distribution National service cover ISO 9001 certified

The of the firematic boiler The system controls the complete energy supply. Digital interface RS 232 CAN-Bus Remote supervision (optional) Remote maintenance (optional) PC-Visualisation (optional) Heating zones modules Solar circuit module Buffer storage management HERZ Buffer storage tank Hot water processing 3000 Additional Heating Solar equipment Weather compensated heating zones Possibility of remote supervision and remote maintenance

Technical Details and... Fuel transport and dust control by: Intermediate fuel storage tank Infrared light barrier system Clean Combustion by: Fuel supply and air control with lambda probe Optimised combustion with low-pressure control Self cleaning burner during operation Infinitely variable regulated primary and secondary air supply Triple burn-back control system: Burn-back safety device for fire control BSD (IBS tested) Fire control unit with 5l water storage FCU Internal screw with electronic temperature control device Reliable ignition with: High-quality hot air fan Sturdy motor with chain drive: High torque moment Low energy consumption

... Dimensions of the firematic boiler! Technical Specification 90 150 Output range kw 27-90 45-150 Max. Permissible feed pressure mbar 0,10 0,15 Permissible operating pressure bar 3,0 3,0 Max. Permissible flow temperature C 90 90 Flue gas temperature C 180 180 Flue gas mass flow kg/s 0,051 0,092 Water capacity L 215 350 Boiler weight kg 1085 1390 Flow dimension (female thread) Zoll 6/4 F 3 Return flow dimension (female thread) Zoll 6/4 F 3 We reserve the rights for technical modifications Dimensions (mm 90 150 A Length 1555 2225 B Width (maximum for access) 920 1200 B1 Width (boiler) 798 998 B2 Width overall 2705 2905 C Height 1725 1725 D Flue pipe diameter 180 250 E Height - Inlet hopper door 320 320 F Width - Inlet hopper door 600 800 G Height for flue centre line 1200 1190 H Height for flow/return connection 1505 1440 I Height for return flow connection -- 770 J Distance boiler centre line to BSD 1305 1405 K Distance for flow/return flow connection 595 -- L Distance between the boiler to the 650 650 end of the ash container firematic: Suitable for every boiler room and storage room Quick responding: No fireclay used therefore quicker response times Fuel level monitoring: Electronically monitored, therefore no wear Customized equipment design by qualified HERZ technicians

Wood chips easily stored HERZ-fuel transport systems allow variable storage room designs in accordance with customer requirements 2 1 3 1 2 3 4 Fuel transport over horizontal spring-arm agitator Fuel bunker with distributing screw conveyor Boiler room with fuel storage above Fuel transport with pendulum screw out of storage silo Fuel transport with torque rod and cross screw conveyor 4 5 Boiler room with fuel storage below Horizontal transport with spring-arm agitator 5 6 7 Fuel storage and boiler room on different levels Horizontal transport with spring-arm agitator Fuel storage and boiler room on same level Angled transport with spring-arm agitator 6 7

Pellets: Heating from 27-150 kw HERZ-Firematic: Environment friendly energy for heating residential dwellings, schools, nurseries and industrial buildings. 1 The high output capacity of the firematic with pellets and wood chips makes it suitable for heating up to 150kW. It is an ideal heating system considering the low fuel prices and the environmental friendly combustion. The operation with wood chips is especially suitable for contracting-models where the wood supplier is also the energy supplier. Pellet systems require less space for fuel storage. 2 1 2 3 Fuel storage for the whole year. Space requirement similar to an oil tank. Construction with swivel screw for space saving storage. Fuel transport with angled screw conveyor For systems without spring-arm agitator the angled slides have to be a minimum of 45 degrees 3

Graphics: www.grafikorange.com. Photos: Art Photos Schrotter, Gleisdorf In harmony with the environment! Energy management with methodology Controlling for the complete heating system Optimum system design Single source supply for all components High fuel economy High performance combustion technology Easy to operate and control Comfortable room temperature control HERZ- Feuerungstechnik exceeds the strict emission regulations Your Partner: HERZ Armaturen Ges.m.b.H. Geschäftsbereich Feuerungstechnik A-8272 Sebersdorf Tel. +43/(0)3333 / 2411-0 Fax +43/(0)3333 / 2411-73 office@herz-feuerung.com www.herz-feuerung.com We reserve the right to make technical modifications GBO-0908