PAGE 2. Figure 1: Difference between PWL ins and SPL 1m



Similar documents
THE MODELING AND CALCULATION OF SOUND RADIATION FROM FACILITIES WITH GAS FLOWED PIPES INTRODUCTION

3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

Acoustic Terms, Definitions and General Information

Exhaust noise control case study for 2800 class locomotive

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Acoustic design with wall acoustic solutions

Sound Attenuation INTRODUCTION

How To Reduce Noise From A Test Screen

Active noise control in practice: transformer station

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Relationship between Sound Pressure and Sound Power Levels

A COMPUTATIONAL METHOD FOR ANALYSIS AND DESIGN OF ACOUSTIC ABSORBERS AND LOW FREQUENCY TRANSMISSION LOSS

Lightweight Partition Design for Residential and Commercial Buildings

Benchmark indicators for industrial noise emission

FLUID FLOW Introduction General Description

Noise Control Solutions For Standby Power Generators

Absorption mufflers in exhaust systems. Rolf Jebasinski. J. Eberspächer GmbH & Co. Abstract

TOP 10 NOISE CONTROL TECHNIQUES

Noise associated with the ground water systems serving residential geothermal heat pumps

Technical insulation. HVAC Ducts Handbook

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

HP switch LP switch Discharge thermo Comp. Surface thermo

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

sound reduction systems for commercial, educational and industrial environments

AS COMPETITION PAPER 2008

Under sill units. Type FSL-B-ZAS

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

Chapter 3.5: Fans and Blowers

Noise. CIH Review PDC March 2012

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

ProRox Slabs (formerly known as RW slabs)

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Some Recent Research Results on the use of Acoustic Methods to Detect Water Leaks in Buried Plastic water Pipes

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

The Behaviour Of Vertical Jet Fires Under Sonic And Subsonic Regimes

NOISE CONTROL REVIEW FOR 4 db NOISE REDUCTION SCENARIO FOR WAGERUP 3 EXPANSION PROJECT FOR ALCOA OF AUSTRALIA

Stilling Well Recommendations

Acoustic Leak Detection. Gander Newfoundland 2006

EXPERIMENTAL RESEARCH ON CHARACTERISTICS OF CENTRIFUGAL PUMP NOISE IN WATER PIPE SYS- TEM

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Physics in Entertainment and the Arts

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Application note for Peerless XLS 10" subwoofer drive units

ROCK WOOL Preformed Pipe Section

CO MPa (abs) 20 C

Colorcoat Technical Paper Acoustic performance of pre-finished steel cladding systems

General Design Principles for an Automotive Muffler

BULLETIN for hotel and restaurant facilities that are subject to 359b GewO 1994

Lecture 9, Thermal Notes, 3.054

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

Free piston Stirling engine for rural development

Control ball valves for severe services. Author: Michele Ferrante, PARCOL S.p.A., Italy

8. ACOUSTICS OF ROOMS AND ENCLOSURES

KRUGER ENERGY CHATHAM WIND PROJECT ENVIRONMENTAL SCREENING REPORT / ENVIRONMENTAL IMPACT STATEMENT. Appendix E. Environmental Noise Impact Assessment

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

Grooved gaskets. Types of gaskets

TFSR & TFSK Roof Fans

A basic introduction to steam

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

The Role of Acoustics in Curtain Wall Design:

Acoustical proprieties of light brick walls and its effects on flanking transmission

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Principle of Thermal Imaging

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Testing methods applicable to refrigeration components and systems

HDA

MEMBRANE VACUUM MINI PUMPS

Diffusion and Fluid Flow

Dispersion diagrams of a water-loaded cylindrical shell obtained from the structural and acoustic responses of the sensor array along the shell

Contents. Microfluidics - Jens Ducrée Physics: Fluid Dynamics 1

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

18 Q0 a speed of 45.0 m/s away from a moving car. If the car is 8 Q0 moving towards the ambulance with a speed of 15.0 m/s, what Q0 frequency does a

Chapter 8: Flow in Pipes

VIPAC ENGINEERS & SCIENTISTS

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

State Newton's second law of motion for a particle, defining carefully each term used.

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

COLD Heat Fire

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Finite Element Analysis for Acoustic Behavior of a Refrigeration Compressor

Solid shape molding is not desired in injection molding due to following reasons.

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

Basic Concepts of Sound. Contents: Definitions db Conversion Sound Fields db ± db

Detecting & Locating Leaks in Water Distribution Polyethylene Pipes

THE PSEUDO SINGLE ROW RADIATOR DESIGN

Pipe Clamps and Accessories

Transcription:

PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation and inplant screening. Large petrochemical sites can often be characterised by the presence of different plants, with kilometres of piping, which can represent a major noise source and a major cause of noise screening. This article suggests ways to treat the noise aspects of piping and the abatement of flow induced noise caused by restrictions and discontinuities in gas and steam piping. Recognition of the noise problem in the design stage should result in the application of low noise valves and accurate acoustic insulation of piping. When taken in combination with installations, piping can also have a screening effect on the transmission of noise. This article gives noise attenuation factors regarding this inplant screening. NOISE CONTROL PROCEDURE In the design phase of a new plant, an adequate noise control procedure is essential to prevent noise specifications being exceeded after realisation. The standard ISO/FDIS 15664, Acoustics - Noise control design procedures for open plant, 1 defines procedures for open plants such as oil refineries and chemical plants. Noise specifications can be given as a maximum sound power level (PWL), which is the amount of noise a source generates, and/or maximum sound pressure level (SPL) at a certain distance from a noise source. This noise source can be defined as a separate installation, a combination of installations, or even an entire plant. SUBSONIC FLOW NOISE CAUSED BY TURBULENCE The following formula can be used to determine the sound power level (PWL ins in db(a) 2 ) inside the pipe, which is caused by turbulence in a medium with a certain density, temperature and velocity: PWL ins = -5 + 60.lg(v f /v 0 ) + 10.lg(S/S 0 ) - 25.lg(T f /T 0 ) + 8.6.lg(D f /D 0 ) where: v f = flow speed in m/s (v 0 = 1 m/s). S = area of cross section (S 0 = 1 m 2 ). T f = temperature in K (T 0 = 273 K). D f = density in kg/m 3 (D 0 = 1 kg/m 3 ). It is important to recognise the strong dependence of velocity on subsonic flow noise. If the velocity in a piping system increases by a factor of two (due, for example, to a 90 o elbow), the PWL downstream increases according to this formula with 18 db(a). SONIC FLOW NOISE AT OVERCRITICAL PRESSURE DROP At an overcritical pressure drop in a piping system near a restriction (P 1 /P 2 > 3), the flow speed exceeds the speed of sound, resulting in a shock wise expansion behind the

PAGE 2 restriction (shock waves). This mechanism is the most important cause of high sound pressure levels near valves, restriction orifices etc. The most important criteria for sonic flow noise follow from the formula regarding the generated sound power level (below): PWL ins = 10.lg(W 2.( P/P 1 ) 3.6.(T/MW) 1.2 ) + 126 where: W = flowrate in kg/s. P = pressure drop in kpa. P 1 = up stream pressure in kpa. T = temperature in K. MW = molecular weight. The T/MW ratio provides an indication of the ratio between the flow speed and the speed of sound. The formula shows a strong pressure drop dependency. Figure 1: Difference between PWL ins and SPL 1m

PAGE 3 DETERMINATION OF DIFFERENCE BETWEEN PWL ins AND SPL 1m In practice, setting limits according to company guidelines often means that a certain sound pressure level (SPL) at 1 m from a sound source should not be exceeded. In the case of hearing loss prevention, the value of 85 db(a) is often used. In order to recognise potential sound problems, an insight must be obtained into the difference between the sound power level inside a pipe (PWL ins ) and the SPL at 1 m (SPL 1m ) as shown in Figure 1. In Figure 1, the insulation value (R) of the piping is the relevant parameter. If steel piping with a schedule 60-80 (being common values for gas and steam piping) is used with diameters of 6-10 in., the sound insulation value (R) is 44-48 db for high frequency noise. The difference between PWL ins and SPL 1m is approximately 36-40 db. In practice, acoustic problems can therefore occur, beginning with PWLs inside the piping of approximately 120 db(a). TURBULENCE GENERATOR WITH SOUND RADIATING SURFACES Typical turbulence amplifiers in piping systems, generating shock waves in many cases, are: Control valves. Restriction orifices. Tees. Elbows. Typical sound radiating surfaces are: (Non-insulated) piping. Piping supports (Figure 2). Flanges. Control valves. Instrumentation.

PAGE 4 Figure 2: Insulation of piping supports. The design stage of a gas or steam piping system should be used to determine potential acoustic problems. Given the company limit setting and the prognosis of SPL 1m, the noise abatement policy should be: Prevention of sound generation in the design phase by limiting flow speeds and preventing unnecessary turbulence amplification. Measures at (potential) turbulence amplifiers. Sound insulation. This policy can also be used for noise abatement in existing situations, although given the existing pipe diameters and flows, measures to reduce the flow speed are often not feasible. NOISE ABATEMENT AT THE SOURCE Some acoustic measures, which aim to influence the origin of sound, are given below. Piping design Piping to and from a (noise critical) control valve has to be designed so that the turbulence caused by the valve is not further amplified due to nearby elbows. The distance between elbow and valve (piping to the valve) has to be 10 times the diameter of the pipe. The distance between valve and elbow (piping from the valve) has to be 20 times the diameter of the pipe. Junctions should not be made at an angle of 90 o, but rather should follow smooth curves.

PAGE 5 Valves Figure 3 shows an example of a turbulence reducing flow divider, applied as a standard in low noise control valves. Figure 3: A turbulence reducing flow divider. If a valve only has a cut off function, a ball valve is preferred over a globe valve for prevention of turbulence. Another example of prevention of noise generation is to create a pressure drop in stages (Figure 4).

PAGE 6 Figure 4: Pressure drop in stages. Restriction orifices A restriction orifice can be made with one hole or a number of holes. While the free crosssection areas are the same in both cases, the reduction of turbulence in the orifice with several holes, as compared with a single hole, can reach approximately 7.lg(n) db(a), where n is the number of holes. Muffler In an effective muffler, gas flows through a diffuser in combination with sound absorbing material (steel wool and/or rock wool). As the muffler only reduces sound radiating at the downstream side of piping, insulation of the muffler housing itself, including the nearby turbulence generating valve, can also be necessary. INSULATION Effect limitations Acoustical insulation of sound radiating surfaces is an effective and relatively cheap way of reducing the high frequency flow noise radiated by piping, piping supports, instrumentation, etc. In practice, piping will often be constructed as a thermal insulation. However, this can only provide effective sound insulation if it is mounted in an acoustically correct way.

PAGE 7 Sound insulating construction Acoustic insulation is generally constructed using a metal outer layer or cladding (steel or aluminium) without any rigid connections with the pipe. Acoustic leaks are avoided using adequate overlaps and sealings. Between the outer layers and the pipe wall, a porous layer is generally provided, for instance mineral fibre (glass or rock) or open cell flexible plastic foam. The mass of the outer layer needs to be sufficient to obtain the required level of insulation. Table 1 gives insulation classes based on the recent standard ISO/FDIS 15665 3. Table 1 Minimum insertion loss required for each class 3 Class Range of nominal diameter (D, mm) Octave band centre frequency (Hz) 125 250 500 1 000 2 000 4 000 8 000 Minimum insertion loss (db) A1 A2 A3 D < 300 300 D < 650 650 D < 1000-4 -4-4 -4-4 2 2 2 7 9 9 13 16 16 19 22 22 24 29 29 30 B1 D < 300-9 -3 3 11 19 27 35 B2 B3 300 D < 650 650 D < 1000-9 -7-3 2 6 11 15 20 24 29 33 36 42 42 C1 C2 C3 D < 300 300 D < 650 650 D < 1000-5 -7 1-1 4 9 11 14 17 23 24 26 34 34 34 38 38 38 42 42 42 In order to conform to a given class, the insertion loss of all seven octave bands will either exceed or be equal to the levels specified. Sound insulation at low frequencies can be negative due to the mass spring resonance and, with smaller pipe diameters, the increase of the noise radiating surface of the outer cladding. This means that in these frequency bands, sound radiation increases as a result of sound insulation. Effective insulation Effective insulation of pipe systems means that each part of the system with a SPL 1m higher than the limit must be insulated. In many cases, supports and parts of the instrumentation that are linked directly to the sound radiating pipe wall also have to be insulated. In some cases, and as an alternative to the insulation of supports, vibration insulators can be applied between a pipe and its support within the acoustic insulation. If, for maintenance reasons, the insulation must be taken off and again be applied in a simple way, removable enclosures should be applied. An example of insulation in a case where the flange has to be ventilated is given in Figure 5 3.

PAGE 8 Figure 5: Vented acoustic insulation of flanged joints. ATTENTUATION FACTORS DUE TO INPLANT SCREENING In the design phase of a new plant, one usually starts by adding up the sound power levels of separate apparatus, installations and piping. This prognosis can be based on noise data obtained from manufacturers and/or experimental data. As a result of neglecting inplant screening, the sum of these different sound power levels generally provides an exaggerated view of the total noise emissions of the plant, particularly when a relatively high density of piping and other equipment surrounds the most dominant noise sources. 4 Inplant screening is defined as the excess attenuation of sound due to diffraction and absorption when transmitted through open process installations. Generally applicable attenuation factors are derived for situations where relevant inplant screening is expected, but where they cannot be determined by practical measurements (in case of predictions or too much disturbing noise in practice). These values of attenuation factors 5 are incorporated in the revised Dutch guideline regarding measuring and calculating industrial noise, (issued in April 1999). 6 However, if inplant screening is to be considered, one should not take into account screening/reflection due to buildings and other objects in the plant of interest. The reduction (D), due to inplant screening, is calculated according to the following formulae: D = t(f). r t (1) D # D max (2) where: t(f) r t = Frequency depended factor regarding inplant screening [db/m]; indicative factors are given in Table 2. = Part of the noise path through the open process installation (Figure 6). Only the part of the curved sound path that transmits through the installations is

PAGE 9 considered as part of r t ; the part mainly above the installations is not taken into account. In the Dutch guideline the radius R of the curved sound path is defined as R = 8.r, where r is the distance between the sound source and the receiving point. D max = Maximum type dependent reduction (Table 2). The values of these attenuation factors are highly dependent on the specific features and density of piping and equipment in the plant. The more installations present, the more reflection and diffraction of noise will occur, causing a higher inplant screening effect. In existing situations, it is preferable to measure the excess attenuation of this inplant screening effect. Special measurement and analytical techniques using cross correlation can diminish the problem of disturbing noise 5. In the case of other situations, Table 2 provides indicative values for three different plant types. Type A relates to plants with a density of installations of approximately 20%/30 m transmission path length through the plant (in the relevant direction). Type B relates to plants with a density of more than 20 %. Tank parks values concern areas with a high number of storage tanks. Table 2 Indicative values of attenuation factor t (f) due to inplant screening (db/m) Description 31.5 63 125 250 500 1 000 2 000 4 000 8 000 type A 0 0 0.02 0.03 0.06 0.09 0.1 0.1 0.1 10 type B 0 0 0.04 0.06 0.11 0.17 0.2 0.2 0.2 20 tank parks 0 0 0.002 0.005 0.005 0.02 0.02 0.02 0.02 10 D max [db] Figure 6: Explanation of r t. The sound pressure levels in the (living) area around an existing industrial site, with many separate open process plants, are often determined by means of a computer model in which the contribution of each plant to the sound pressure level at certain points in the surrounding area is calculated. The necessary sound power levels of

PAGE 10 separate plants are often based on contour measurements around each plant, in accordance with ISO 8297 7. In these situations, the application of inplant screening attenuation factors has proven to be very useful when the emitted sound of a certain plant is transmitted through adjacent open plant(s). Neglecting this excess attenuation can cause significant differences between calculated and measured sound levels in the surrounding areas, and as a consequence strongly influences the need and extent of sound reduction measures. If measurement of the reduction effect of inplant screening is not possible, the inplant screening factors, as mentioned in Table 2, can be useful. CONCLUSION In the design phase of an open plant, adequate noise control procedures such as ISO/FDIS 15664 are essential. Noise aspects of piping are important in open plants because of the vast number of pipe systems. When sound limits must be met at 1 m from pipe systems, valves, etc., the acoustic behaviour of the system should be foreseen in the design phase. Noise abatement at the source can significantly reduce sound emissions, and can sometimes lead to the elimination of the sound source. Implementation in existing situations is more expensive than the recognition of potential acoustic problems and determination of measures in the design phase. Given the contributions of specific parts of the pipe system, sound insulation must be executed with great care if it is to be effective. When noise limits must be met in the environment of an industrial plant, inplant screening must be considered because, due to this effect, the real emissions of an industrial plant might be lower than those calculated. REFERENCES 1. ISO/FDIS 15664, Acoustics Noise Control design procedures for open plant, 2001. 2. Geräusche bei Rohrleitungen; ( Noise at pipes ), VDI Handbuch Lärmminderung 3733, July 1996. 3. ISO/FDIS 15665, Acoustics - Acoustic insulation for pipes, valves and flanges, 2003. 4. Granneman J.H., Jansen R.P.M., Sound power determination of large open plants; comparison of alternative methods, Internoise 99, December 1999. 5. Granneman J.H., Beer E.H.A. de, Schermer F.A.G.M., Inplant screening in petrochemical sites, Internoise 93, August 1993. 6. Guide for measuring and calculating industrial noise, guideline issued by Dutch Ministry of Environment, April 1999. 7. ISO 8297, Acoustics Determination of sound power of multisource industrial plants for evaluation of sound pressure levels in the environment, Engineering Method, 1994.