Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs



Similar documents
Life safety solutions. protecting every single asset

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Faraday Intelligent Fire Detection Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

The ONYX Series. The Ultimate in Fire Protection Technology

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

SECTION FIRE ALARM AND DETECTION SYSTEMS

SECTION DETECTION AND ALARM

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire detection equipment

SUPPRESSION CONTROL PANELS

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

Potter Plus. Fire Alarm Control Panels

A World of Solutions. Life Safety and Emergency Communications Systems Information Guide.

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

EXHIBIT A SCOPE OF WORK

University Design Standard. Fire Alarm Systems

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

SECTION FIRE ALARM SYSTEM

SECTION FIRE ALARM AND DETECTION SYSTEM

Alliance System Ordering Guide

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

DTW Works Master Specification Version 2006

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Voice alarm system E100 the new standard for safe evacuation

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Intelligent Fire Detection & Alarm and Mass Notification System.

C. Conform to requirements of Americans with Disabilities Act (ADA).

Fire Alarm System Plans Review Checklist Property location Date of Review

Module 5. Fire and Emergency Alarm System Part I- Basics

Security Alarm - Fire Alarm system Central Monitoring Services Promotion Packages

PLAN REVIEW GUIDE FOR FIRE ALARM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

MINERVA MX MX Virtual Multi-Sensor Detectors

TrueAlarm Fire Alarm Systems

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

SECTION FIRE ALARM AND DETECTION SYSTEM

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Versatile. EST3X Life Safety Solutions. An EDWARDS brand.

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Module 4, Lesson 12 Fire Alarm Systems

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Innovative Fire, Security and Communication Solutions

The Mission Critical Fire Protection Experts

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 50 - POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM

Life Alarm Fire Alarm Controls

Life Safety Innovation Delivering energy-efficient & intelligible notification solutions

Notification Solutions Campus

Residential & Commercial Alarm Systems by Gross Security, LLC

EDWARDS SIGNAL SOLUTIONS DISTRIBUTED BY: Lee Dan Communications, Inc. Toll-Free:

NETWORKING AND INTEGRATION

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE DETECTION SYSTEMS. elan Fire Alarm Product Guide

Solution Ultima ICP-CC488 Home security you can rely on

FIRE ALARM SYSTEM RECORD OF COMPLETION

USER INSTRUCTIONS CONTENTS

Fire alarm system EBL512 G3

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Understanding Alarm Systems

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Product Guide Specification

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Fire Alarm Control Panel NFS-320/E/C, NFS-320SYS/E. Operations Manual. Document /16/2011 Rev: E1 P/N 52747:E1 ECN

ERS-2400B. PERS-2400B Personal Emergency Reporting System

City of Bettendorf Fire Alarm System Requirements

SMART SENSOR COLLECTION

FIRE DETECTION AND ALARM

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

FIRE ALARM APPLICATION

Solution Ultima ICP-CC488 Home security you can rely on

SECTION FIRE ALARM AND DETECTION SYSTEM

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

1.0 General. Inspection, Testing, and Maintenance 1 of 8

I N T E L L I G E N T F I R E A L A R M C O N T R O L S Y S T E M S

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

EQUIPMENT SPECIFICATIONS

D9412GV3/D7412GV3. Approved Applications Compliance Guide. Control Panels

Transcription:

Building Solutions One Honeywell Solution for All of Your Fire Systems Needs

Intelligent and Accurate Detection Fire/CO The Advanced Multi-Criteria Fire/CO is a plug-in, addressable device that provides both fire and Carbon Monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, infrared and heat) to sense multiple components of a fire. This approach has enhanced sensitivity to a real fire with heightened immunity to nuisance particulate. For CO, the detector s electrochemical sensing cell creates a separate signal for life safety CO detection. When used together with our addressable sounder base, you can replace as many as four separate devices for a cleaner and more efficient installation. COPTIR COPTIR senses smoke particulate from Carbon Monoxide (CO), thermal, photo, and infrared signatures simultaneously to determine the presence of a fire condition. Sensor readings are continually evaluated against one another, allowing the detector to operate normally with high immunity to nuisance conditions, while quickly responding to true alarm events. ACCLIMATE The Acclimate detector combines thermal and photoelectric technologies into a single device. It constantly monitors ambient heat and particulate conditions, adjusting sensitivity parameters and alarm thresholds automatically to maximize detection across a broad range of fire types. FAAST Fire Alarm Aspiration Sensing Technology (FAAST) solutions provide early warning of an impending fire hazard. FAAST can buy time to investigate an alarm and initiate an appropriate response to prevent injury, property damage, or business disruption. With a wide sensitivity range and multi-level warnings, even minute levels of smoke can be detected before a fire has time to escalate. It is also possible to connect the unit to the building s Ethernet connection in order to provide access and monitoring from anywhere in the world. ECLIPSE The Eclipse TM family is an innovative line of detection and notification devices, which boasts a completely digital, powerful and extremely fast protocol. Unmatched in the industry, this protocol is one of many unique features of the XLS3000 Fire Alarm System. Other benefits include: Intelligence in the head via distributed processing; digital protocol for speed, accuracy, and error detection; peer-to-peer device communication; and adaptable to existing wiring Integral Isolators such as loop reliability (short circuit protection, earth fault detection) Auto addressing; As-wired mapping - cable tree structure; and providing Style 7 operation Electronic addressing features such as Unique Serial Number; device replacements can be found and automatically addressed; and eliminates dual addressing

Emergency Communications and Annunciation Honeywell fire alarm control panels are paired with a variety of customized and effective visual, audible, and textual/ DRMNS emergency notification products. These products ensure facility occupants are notified of emergencies and communicate action and direction for the proper response. This aids significantly in the proper accountability of personnel during potential evacuation. First Responder Honeywell s First Responder is a revolutionary touch screen graphical interface that simplifies emergency scene assessment from a building lobby. Emergency responders can immediately gather the information needed to accurately pinpoint the source of the fire and the rate at which it s spreading, enabling them to quickly locate and extinguish the fire. Indoor/Outdoor Notification SpectrAlert Advance is a visual/audible fire and non-fire emergency notification products line. SpectrAlert Advance line supports indoor and outdoor use, along with different lens colors for various emergency types. Plug-in design; bases wire separately Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 145, 150, 177, 185 Captive mounting screw Tamper resistance capability Automatic selection of 12-or-24 volt operation at 15 and 15/75 candela Shorting spring on mounting plate for continuity check before installation Outdoor wall and ceiling products rated from -40 F to 151 F Giant Voice The Whelen Emergency Communication warning system is an omni-directional voice and siren warning system, installed around an industrial facility to alert occupants and surrounding areas of emergency conditions. One to ten omni-directional speaker cells assembled in a vertical column Ten models, 109dBc to 129 dbc @ 100 All WPS2900 speaker cells include high efficiency 400 watt EZ-PULL speaker drivers Power amplifiers Tone generator Textual/DRMNS Notification Indoor/Outdoor Horn/Strobe Textual and Distributed Recipient Mass Notifications Systems (DRMNS) are a multi-faceted approach that utilizes an organization s existing IP network as the basis for an emergency notification and communications system. These systems also allow for specific user groups to be established so that targeted communications can be sent. In addition, they interface with the fire and gas system with relay or high-level interfaces. Telephone Cell Phone Text Messaging Email Desktops LED Displays

XLS120 / XLS140-2 System XLS140-2 Fire Alarm Control Panel EIA-232 SLC SLC XLS-PRN-6 Printer XLS-120 Fire Alarm Control Panel XLS-NET TC806B Photo TC840M Acclimate TC809A1059 FAAST Aspiration LCD2--80 Remote Annunciator TC807B Ion TC846A PINNACLE TC840C2010 Multi-Criteria Fire/CO TC808B Thermal XLS-NCA2 DNR Duct TC847A Addressable Beam TC840C COPTIR FNA-3 Fire Network Adapter TC809A IP TC841A 2-Wire 2151 Photo 2WB Photo Honeywell Enterprise Building Integrator S464G Addressable Manual Pull Station Intelligent Devices ACPS-610 Addressable Charger Power Supply P2RH Horn/Strobe HR Horn Peripheral Devices SCW Strobe Intelligent 1 Loop Fire Alarm Control Panel 318 FlashScan TM devices (159 detectors and 159 modules) per loop Expandable to 2 SLC loops (XLS140-2 only) Honeywell Enterprise Buildings Integrator (EBI) compatible UL 864, Ninth Edition listed Supports Honeywell CLIP and FlashScan TM addressable devices Complete intelligent system feature set with digital protocol, 9 levels of sensitivity, drift compensation and maintenance alert, and auto detector test 6.0 amp switch mode power supply with four Class A/B built-in NAC (Notification Appliance Circuits). Selectable System Sensor strobe synchronization Fully field programmable with 80-character display (includes QWERTY keypad) or offline with VeriFire Tools programming utility Supports Direct Connect to the XLS-DVC Digital Voice Command (XLS140-2 only) XLS-NET compatible up to 102 nodes for standard networking or 200 nodes for high speed networking Unique environment detection includes Pinnacle for clean environments, COPTIR for critical environments, and Acclimate a multi sensor that adjusts sensitivity automatically Optional universal 2040-point DACT

XLS3000 System EIA-485 EIA-232 LCD-160 Display SCS Smoke Control Station Custom Graphics Annunciator ACS LED Annunciator UDACT-2 Digital Alarm Communicator SLC Loop (Up to 10) XLS-PRN-6 Printer XLS3000 Fire Alarm Control Panel TC906A Photo TC809A FAAST Aspiration XLS-NET EA-CT Eclipse Infrared Tool TC807B Ion TC840C2010 Multi-Criteria Fire/CO XLS-NCA2 DNR Duct TC840C COPTIR IP FNA-3 Fire Network Adapter TC809A TC910R Relay Module Honeywell Enterprise Building Integrator S464G Addressable Manual Pull Station Intelligent Devices TC910N Control Module P2RH Horn/Strobe HR Horn Peripheral Devices SCW Strobe PF24V ExitPoint TM with Voice Intelligent 1 to 10 Loop Fire Alarm Control Panels Honeywell Enterprise Buildings Integrator (EBI) compatible UL 864, Ninth Edition listed 1-10 Signaling Line Circuits Style 4, 6 or 7 Supports Honeywell CLIP, ECLIPSE, and FlashScan addressable devices Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multisensor) and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay) per SLC Honeywell SMART capable 250 Eclipse devices (125 detectors and 125 modules) per loop Large 640-character LCD backlit display (16 lines x 40 characters) or displayless (a node on a network) XLS-NET compatible (up to 102 nodes for standard networking or 200 nodes for high-speed networking Application code is saved in FLASH memory, eliminating the need to change EPROMs Supports Direct Connect to the XLS-DVC Digital Voice Command Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week Optional universal 2040-point DACT EIA-485 annunciators, including custom graphics Unique environment detection includes Pinnacle for clean environments, COPTIR for critical environments, and Acclimate a multi sensor that adjusts sensitivity automatically FM6320 approved Gas Detection System with TC809C module and any FM approved gas detector

XLS-DVC Digital Voice Command Background Music, Paging and Emergency Communication System Input Up to 32 Digital Audio Amplifi ers Digital Audio Riser Up to 4 Speaker Circuits Low Level Audio Channel Output Digital Audio Amplifi er Digital Audio Loop Firefi ghter Telephone Circuit Outdoor Voice XLS3000 with XLS-DVC-EM Digital Voice Command Background Music, Paging and Emergency Communication System Input AA Series Amplifi er Low Level Audio Channels Low Level Audio Channel Outdoor Voice Output XLS140-2 with XLS-DVC-EM Digital Voice Command TC810N Control Module Speaker Eight channels of audio messages and five channels of fire telephones over the digital audio loop Digital audio loop compatible with wire, single mode and multi-mode fiber Up to 32 minutes of digital audio message/tone storage Up to 1000 audio sequences Messages are created with standard.wav files Digital audio ports for direct connection with up to 32 digital amplifiers. Two auxiliary low level audio inputs Programmable via VeriFire Tools programming utility Honeywell Enterprise Buildings Integrator (EBI) compatible XLS-NET Compatible Can provide analog low level audio output for retrofit applications Allows for multiple command centers and expansion up to thousands of digital amplifiers Live paging over XLS-NET Isolated alarm bus input for fail safe degraded mode operation. History buffer for local event storage Delivers cost effective digital audio through traditional analog amplifiers Interface with giant voice system for outdoor applications

Panel Comparison XLS-120 XLS140-2 XLS3000 SLC Protocol Capability Maximum number of SLCs 1 2 10 Honeywell CLIP Capable Yes Yes Yes Honeywell FlashScan TM Capable Yes Yes Yes Honeywell Eclipse TM Capable No No Yes SLC Autoprogram Yes Yes Yes EBI & Networking Compatibility XLS-NET Compatible Yes Yes Yes Full EBI Integration Yes Yes Yes Audio Capability Standalone Audio w/analog Amplifiers No Yes Yes Standalone Audio w/digital Amplifiers No Yes Yes Networked Digital Audio Capable No Yes Yes Programming Options SMART TM Capable No No Yes Logic Zones 99 99 1000 Releasing Zones 10 10 10 Main Power Supply Battery Capacity 200 AH 200 AH 200 AH Display Options 80 Character Yes Yes No 640 Character No Yes Yes Displayless No Yes Yes Remote LCD Annunciator 80 Char. 80 char. 640 char. Regulatory Approvals UL 9th Edition Yes Yes Yes ULC Yes Yes Yes FM Yes Yes Yes MEA Yes Yes Yes CSFM Yes Yes Yes City of Chicago No No Yes SMART TM Properly maintaining a fire alarm system is critical to ensure that it will work when it is needed the most. The problem with the average fire alarm system is that it does little more than tell you when it has already been compromised. Only the Honeywell XLS3000 offers the patented (US 7,161,481 B2) System Maintenance Analysis Reporting Tool (SMART TM ), which provides an unparalleled amount of service and maintenance information to the owner. SMART TM is Honeywell technology to track the required installation, inspection, testing and maintenance frequencies of your Fire Alarm System. SMART TM is a software algorithm in XLS3000 that: Knows local (regional) testing requirements Verifies all system points are tested at installation Tracks periodic testing Reports devices that require testing and those coming due for service Verifies that changes to the system are tested, speeding recertification Alerts building owner when testing is required Independently verifies to the owner that service is being performed SMART TM is Honeywell s way to deliver: Piece of Mind for the Building Owner - That the fire alarm system is operating normally - That the service company is performing their work - That interruptions to the building activities are minimized - That their investment is being optimally protected Code Compliance for: - Fire Marshall - Building Inspector - On-site Safety Personnel SMART TM is one of many key advantages of the Honeywell XLS3000 Fire Alarm System when used with its revolutionary Eclipse TM family of detectors and modules.

More Information For more information about Honeywell Building Solutions, call 1-800-345-6770, ext. 603. Or e-mail buildingsolutions@honeywell.com Honeywell Building Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422-3992 Tel: 1-800-345-6770, ext. 603 Outside North America: +1-480-592-3248 www.honeywell.com SL 53-2006-1 June 2012 Printed in U.S.A. 2012 Honeywell International Inc.